Quick Installation Guide
Shielded Cat6A Keystone Jack – 6-Pack
TC-K06C6A
1. Strip approximately 40mm (1.6 in.) of jacket from the twisted pair cable.
2. Firmly press the termination cap into the keystone jack outlet until all wires are properly terminated.
3. Insert the cable into the termination cap and fan out all four twisted pairs.
Using the T568A or T568B color labeling, position each wire appropriately into the color labeled slots. Cut excess wires.
1.6"
4. Secure the hinged panels using a crimping tool until they are firmly snapped together.
5. Fasten the cable tie around the cable fixture to secure the cable to the keystone jack.
Cable Tie
Unloading the cable
1. Cut the cable tie.
2. Using a flathead screwdriver, gently prey each side of the hinged panels until released.
1.
2.
3.
6.
4.
5.
7.
8.
T568A/T568B Pinout
T568A
White Green
T568B
White Orange
Orange Green
White Orange
Orange
White Green
Green
Blue
White Blue
White Brown
Brown
Cable Fixture