AMS AS1115 Power Management User Guide

Add to my manuals
6 Pages

advertisement

AMS AS1115 Power Management User Guide | Manualzz

austriamicrosystems AG is now

ams AG

The technical content of this austriamicrosystems document is still valid.

Contact information:

Headquarters: ams AG

Tobelbaderstrasse 30

8141 Unterpremstaetten, Austria

Tel: +43 (0) 3136 500 0 e-Mail: [email protected]

Please visit our website at www.ams.com

AS1115 - Demo Board Manual

RGB

RGB Demo Board Manual

AS1115

Keyscan

64 LEDs, I²C Interfaced LED Driver with

www.austriamicrosystems.com/AS1115

AG still valid

Technical www.austriamicrosystems.com Revision 1.00 1 - 5

AS1115 - Demo Board Manual

RGB

General Description

Board Description

A

B

Name

VDD

GND

Description

Supply Voltage

Ground

C

D

Note:

USB

I / O

Mini USB 5-pin Connector

Interface Connector

Use only the Connectors VDD possibilities at the same time!

“A” and GND ”B” standard USB port. see Interface Connector Description below AG

“C” . Never use both supply

Figure 1: Board Description - Connectors Figure 2: Board Description – Measurement Points

Connector Description

Label Info

Supply voltage ranging from 2.7V to 5.5V

Supplies the AS1115 with 5V. Connect to a still valid

I/O - Interface Connector “D” Description

A1

A2

A3

B1

B2

B3

Label

A1

A2

A3

B1

B2

B3 SDA

Name

KeyA

NC

GND

IRQ

SCL

AS1115 ams

Pin 21

Pin 11

Pin 22 content

Measurement Point Description

Info Label

H

I

E

F

G

Name

VDD

GND

SDA

IRQ

SCL

Description

Supply Voltage

Ground

Serial Data I / O

Interrupt Request Output

Serial Clock Input

Measurement Points

Technical www.austriamicrosystems.com Revision 1.00 2 - 5

AS1115 - Demo Board Manual

RGB

Software

To use the AS1115 RGB Demoboard a controller is required. The controller can be connected to the demoboard via the I/O Connector “D” .

If no controller is available the austriamicrosystems USB box in combination with the AS1115 RGB Demoboard software can be used as well. This USB box is needed to set-up the connection between the demoboard and the

USB interface of a PC. The USB box can be ordered via http://www.austriamicrosystems.com

.

To get the AS1115 RGB Demoboard running set the Interface to I²C and the Nr. of Chips to 3. The black drawn boxes represent the single RGB-LEDs and the gray small boxes represent one color of the RGB-LEDs. Click them to turn the LED on.

AG still valid

Operational sequence

This demo board comes with two AS1115.

1. Drive the IC on the demo board only with the recommended settings and values as described in the datasheet . If not present get the datasheet for the AS1115 from www.austriamicrtosystem.com

.

2. First connect the power supply via connector “C” to a powered USB port and than power up the I/O -

Interface “D” . To power down the system disconnect first the I/O Interface and than the power supply of the demoboard.

3. Connect the I/O - Interface “D” to a µC or via the austriamicrosystems USB Interface Box to a PC. For interfacing please see the corresponding datasheet of the AS1115. Technical www.austriamicrosystems.com Revision 1.00 3 - 5

AS1115 - Demo Board Manual

RGB

Layout of Demo Board

Board schematics and layout

Figure 3: Schematics

Figure 4: Top Layer Technical www.austriamicrosystems.com Revision 1.00

AG still valid

4 - 5

AS1115 - Demo Board Manual

RGB

Copyright

Copyright © 1997-2010, austriamicrosystems AG, Tobelbaderstraße 30, 8141 Unterpremstätten - Graz, Austria -

Europe. Trademarks Registered ®. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner.

All products and companies mentioned are trademarks or registered trademarks of their respective companies.

Disclaimer

Devices sold by austriamicrosystems AG are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. austriamicrosystems AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Austriamicrosystems AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with austriamicrosystems AG for current information.

This product is intended for use in normal commercial applications. Applications requiring extended temperature valid show deviations from the standard production flow, such as test flow or test location.

The information furnished here by austriamicrosystems AG is believed to be correct and accurate. However, austriamicrosystems AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise AG still

Contact Information

Headquarters austriamicrosystems AG

Tobelbaderstraße 30

A-8141 Unterpremstätten - Graz, Austria

T. +43 (0) 3136 500 0

F. +43 (0) 3136 5692 Technical www.austriamicrosystems.com Revision 1.00 5 - 5