AS1115 - Demo Board Manual
RGB
RGB Demo Board Manual
AS1115
Keyscan
64 LEDs, I²C Interfaced LED Driver with
www.austriamicrosystems.com/AS1115
AG still valid
Technical www.austriamicrosystems.com Revision 1.00 1 - 5
AS1115 - Demo Board Manual
RGB
General Description
Board Description
A
B
Name
VDD
GND
Description
Supply Voltage
Ground
C
D
Note:
USB
I / O
Mini USB 5-pin Connector
Interface Connector
Use only the Connectors VDD possibilities at the same time!
“A” and GND ”B” standard USB port. see Interface Connector Description below AG
“C” . Never use both supply
Figure 1: Board Description - Connectors Figure 2: Board Description – Measurement Points
Connector Description
Label Info
Supply voltage ranging from 2.7V to 5.5V
Supplies the AS1115 with 5V. Connect to a still valid
I/O - Interface Connector “D” Description
A1
A2
A3
B1
B2
B3
Label
A1
A2
A3
B1
B2
B3 SDA
Name
KeyA
NC
GND
IRQ
SCL
AS1115 ams
Pin 21
Pin 11
Pin 22 content
Measurement Point Description
Info Label
H
I
E
F
G
Name
VDD
GND
SDA
IRQ
SCL
Description
Supply Voltage
Ground
Serial Data I / O
Interrupt Request Output
Serial Clock Input
Measurement Points
Technical www.austriamicrosystems.com Revision 1.00 2 - 5
AS1115 - Demo Board Manual
RGB
Software
To use the AS1115 RGB Demoboard a controller is required. The controller can be connected to the demoboard via the I/O Connector “D” .
If no controller is available the austriamicrosystems USB box in combination with the AS1115 RGB Demoboard software can be used as well. This USB box is needed to set-up the connection between the demoboard and the
USB interface of a PC. The USB box can be ordered via http://www.austriamicrosystems.com
.
To get the AS1115 RGB Demoboard running set the Interface to I²C and the Nr. of Chips to 3. The black drawn boxes represent the single RGB-LEDs and the gray small boxes represent one color of the RGB-LEDs. Click them to turn the LED on.
AG still valid
Operational sequence
This demo board comes with two AS1115.
1. Drive the IC on the demo board only with the recommended settings and values as described in the datasheet . If not present get the datasheet for the AS1115 from www.austriamicrtosystem.com
.
2. First connect the power supply via connector “C” to a powered USB port and than power up the I/O -
Interface “D” . To power down the system disconnect first the I/O Interface and than the power supply of the demoboard.
3. Connect the I/O - Interface “D” to a µC or via the austriamicrosystems USB Interface Box to a PC. For interfacing please see the corresponding datasheet of the AS1115. Technical www.austriamicrosystems.com Revision 1.00 3 - 5
AS1115 - Demo Board Manual
RGB
Layout of Demo Board
Board schematics and layout
Figure 3: Schematics
Figure 4: Top Layer Technical www.austriamicrosystems.com Revision 1.00
AG still valid
4 - 5
AS1115 - Demo Board Manual
RGB
Copyright
Copyright © 1997-2010, austriamicrosystems AG, Tobelbaderstraße 30, 8141 Unterpremstätten - Graz, Austria -
Europe. Trademarks Registered ®. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner.
All products and companies mentioned are trademarks or registered trademarks of their respective companies.
Disclaimer
Devices sold by austriamicrosystems AG are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. austriamicrosystems AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Austriamicrosystems AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with austriamicrosystems AG for current information.
This product is intended for use in normal commercial applications. Applications requiring extended temperature valid show deviations from the standard production flow, such as test flow or test location.
The information furnished here by austriamicrosystems AG is believed to be correct and accurate. However, austriamicrosystems AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise AG still
Contact Information
Headquarters austriamicrosystems AG
Tobelbaderstraße 30
A-8141 Unterpremstätten - Graz, Austria
T. +43 (0) 3136 500 0
F. +43 (0) 3136 5692 Technical www.austriamicrosystems.com Revision 1.00 5 - 5
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project