END SUCTION PUMPS
1650 1620
Model 1650
INSTALLATION AND
OPERATION MANUAL
pentair.com
FM-03-536 (11/12/19)
Model 1620
1
TABLE OF CONTENTS:
SECTION .................................................................................................................................................................................................PAGE
General Information ................................................................................................................................................................................ 3
Transport and Storage ............................................................................................................................................................................ 4
Product Description ............................................................................................................................................................................... 5
Pump Installation ............................................................................................................................................................................... 6-12
Pump Operation ................................................................................................................................................................................ 13-15
Pump Maintenance and Service ...................................................................................................................................................... 16-20
Troubleshooting Guide ..................................................................................................................................................................... 21-22
Assembly Exploded View .................................................................................................................................................................23-24
Part List ................................................................................................................................................................................................ 25
Pump - Impeller Size Relation ............................................................................................................................................................... 26
Standard Limited Warranty .................................................................................................................................................................. 27
GENERAL INFORMATION
NOTICE to the installer:
Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.
This manual contains important information for the safe use of
Pentair Fairbanks Nijhuis® 1600 End Suction Pumps. Read this manual completely before using this product. DO NOT DISCARD OR LOSE THIS
MANUAL.
Pentair Fairbanks Nijhuis 1620 Series pumps are frame mounted. They feature high efficiency, rugged construction, foot mounted volutes with back pullout power frames, center drop out spacer couplings
(optional) and regreasable ball bearings. The pump’s stainless steel fitted construction is suitable for unheated domestic, fresh water, condensate, boiler feed water, pressure boosting and hydronic coiling and/or heating.
SAFETY
Explanation of Designations
warns about hazards that will cause serious personal injury, death or major property damage if ignored.
warns about hazards that can cause serious personal injury, death or major property damage if ignored.
warns about hazards that will or can cause minor personal injury or property damage if ignored.
NOTICE:
indicates special instructions which are important but not related to hazards.
Guards must not be removed while the pump is operational. Always follow lock out – tag out procedures when working on equipment that may turn on.
Isolate the pump from any fluid in the system and then drain any remaining fluid from the pump casing before proceeding with dismantling the pump. The appropriate safety precautions should be taken where the pumped liquids are hazardous.
Fluoroelastomers (when fitted) :
When a pump has experienced temperatures over 135°C (275°F), partial decomposition of fluoroelastomers (example: Viton™) will occur. In this condition these are extremely dangerous and skin contact must be avoided.
Handling components:
Many precision parts have sharp corners, thus wearing of appropriate safety gloves and equipment is required when handling these components. To lift heavy pieces above
25 kg (55 lb.) use a crane appropriate for the mass and in accordance with current local regulations.
Thermal shock:
Rapid changes in the temperature of the liquid within the pump can cause thermal shock, which can result in damage or breakage of components and should be avoided.
Never apply heat to remove impeller.
Noise & vibration levels:
Pentair Fairbanks Nijhuis 1600
End Suction pumps have been designed to meet the noise and vibration levels as per the Hydraulic Institute (HI) standard 9.6.4.
General Guidelines
• These instructions must always be kept close to the product's operating location or directly with the product.
• These instructions should be read prior to installing, operating, using and maintaining the equipment in any region worldwide. The equipment must not be put into service until all the conditions relating to safety, noted in the instructions, have been met.
• The product must not be operated beyond the parameters specified for the application. If there is any doubt as to the suitability of the product for the application intended, contact Pentair Fairbanks
Nijhuis Customer Service for advice, quoting the serial number.
Personnel Qualification and Training
All personnel involved in the operation, installation, inspection and maintenance of the unit must be qualified to carry out the work involved.
If the personnel in question do not already possess the necessary knowledge and skill, appropriate training and instruction must be provided. It is responsibility of owner or operator to provide training for all personnel involved in the operation, installation, inspection and maintenance of the equipement.
It is recommended that proper documentation of personnel should be maintained by the responsible part(ies).
Personnel Safety Actions
CALIFORNIA PROPOSITION 65 WARNING:
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Never do maintenance work when the unit is connected to power. Always follow lock out – tag out procedures when working on equipment that may turn on.
Electrical Safety
Sudden start-up hazard:
Disconnect and lock out power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage.
Electrical shock hazard:
All electrical connections are to be made by a qualified electrician in accordance with all codes and ordinances. Failure to follow these instructions could result in serious personal injury, death or property damage.
Electrical overload hazard:
Ensure all motors have properly sized overload protection. Failure to follow these instructions could result in serious personal injury, death or property damage.
High Temperature Safety
Hot surface hazard:
If pumping hot water, ensure guards or proper insulation is installed to protect against skin contact with hot piping or pump components. Failure to follow these instructions could result in serious personal injury, death or property damage.
Spraying water hazard:
When servicing pump, replace all gaskets and seals. Do not reuse old gaskets or seals. Failure to follow these instructions could result in serious personal injury, death or property damage.
High Pressure Safety
High pressure hazard:
All the pumps are designed for specific maximum working pressure. Do not exceed this pressure.
Install properly sized pressure relief valves in system. Failure to follow these instructions could result in serious personal injury, death or property damage.
Expansion hazard:
Water expands when heated. Install properly sized thermal expansion tanks and relief valves. Failure to follow these instructions could result in serious personal injury, death or property damage.
FM-03-536 (11/20/19)
3
TRANSPORT AND STORAGE
• Ensure correct lubrication. See “Lubrication” on Page 13 for lubrication instruction.
• Start the pump at reduced speed or with the discharge valve partly opened. This is recommended to minimize the risk of overloading and damaging the pump motor at full or zero flow. Pumps may be started with the valve further open only on installations where this situation cannot occur. The pump discharge control valve may need to be adjusted to comply with the duty following the run-up process.
See “Pump Operation” on page 13.
• Suction valves should be fully open when pump is running.
• Do not run the pump continuously outside the allowable operating region.
• Operating at a flow rate higher than normal or at a flow rate with no backpressure on the pump may overload the motor and cause cavitation. Low flow rates may cause a reduction in pump/bearing life, overheating of the pump, instability, and cavitation/vibration. Running the pump at a flow rate below the manufacturer’s recommended minimum flow rate can cause damage.
• Handling, transportation and installation of this equipment should only be undertaken by trained personnel with proper use of lifting equipment. See “Uncrating and Lifting” Figures 1A and 1B for reference.
• Only water or other suitable HVAC media may be circulated through the use of these pumps. Circulation of hazardous, corrosive or flammable liquids by using these pumps is strictly prohibited.
• DO NOT turn on the electrical supply to the pump until all the plumbing connections and commissioning procedure have been completed.
• The pump must not be operated dry without fluid.
• Pipe systems must be installed in such a manner so there is no pipe strain and no piping loads are being transferred on pump flanges.
• Ensure that the motor installation instruction manual has been followed for determining the proper terminal connections so that correct pump rotation is obtained.
While lifting the pump or pump set (with or without driver) suitable lifting equipment of adequate capacity should be used. The unit should be unloaded and handled by lifting equally. Entire pump with base frame should be lifted at four or more points provided in base frame. Attach nylon slings, chains, or wire rope to the hooks or clevises for lifting.
Ensure that the lift angle of the slings, chains or wire rope is less than
45° from vertical.
Do not use lifting lugs on drivers or pumps to lift base plated units; these are only for the individual driver or pump.
Extra care must be taken when lifting base plated pump units without driver because of the unbalanced load that may exist due to the driver not being mounted on the base.
Figure 1A
Lifting of Pentair Fairbanks Nijhuis* 1620 pump assembly
Lifting of 3804 pump assembly
TRANSPORT AND STORAGE
Transport and Handling Requirements
The pump has been prepared for shipment at the factory in such a way as to minimize potential damage due to handling and transport.
The equipment should not be subjected to excessive G-forces during the handling or transport. For large, heavy, rotating components, the manufacturer shall consider and adapt a means to restrict the movement of the rotating assembly to prevent damage to the bearings during transport. All such means shall be removed before installation.
Uncrating and Lifting
Pump is fastened securely to the crate before shipment. The pump should be removed from the crate carefully by using proper tools and equipment. After removing from crate make sure that all the components are in good condition and have been received as mentioned in the packing list. Report immediately to the concerned person/department if any component is missing or received in a damaged condition. Extreme care must be taken while handling the pump set. Slings and hooks should be used in such a manner, so that while lifting the pump is not exposed to stresses.
Figure 1B
Figure 1B
Receipt, Inspection, and Damage Reporting
Upon receipt of the pump, immediately check for shortages of parts and damages. Prompt reporting to the carrier’s agent, with notations made on the freight bill, may expedite resolution by the carrier.
Immediately upon receipt of the pump equipment, check carefully to see that all items have been received and are undamaged. Report any shortage or damage to the transport company handling the shipment and to the equipment manufacturer, noting the extent of damage or shortage on the freight bill and bill of lading. This should be done at once. Do not unpack any more than required to verify that the equipment is complete
4
FM-03-536 (11/20/19)
PRODUCT DESCRIPTION
and undamaged unless installation is to be done immediately. Do not leave the pump unit or any accessories exposed to weather or construction hazards, which may cause damage to the equipment.
• Bearings must be lubricated with fresh lubricants when pump is being put into service after a long time.
Unpacking
As stated above, do not unpack any more than required to verify that the equipment is complete and undamaged unless installation is to be done immediately. Check all packing material that is to be discarded to verify that no parts or instructions are being accidentally discarded as well. It is best to leave small parts in their shipping container until installation so they do not get misplaced. Make certain that accessories with a pump unit are clearly marked showing which pump unit they are to be used. Clean all parts of dirt, packing materials, and other foreign matter.
Clean all non-coated machined surfaces. If the pump is to be installed immediately, then clean all coated machined surfaces too. Remove any rust spots found on the machined surfaces with a fine emery cloth.
Clean all threaded connections and any accessory equipment.
Storage
The standard packaging is suitable for protection during shipment and during covered storage at the jobsite for a short period between installation and start-up. The preservatives applied at the factory have an effective life of two to three months from date of shipment, depending on the severity of the environment in which the equipment is stored.
Disposal of Packaging Materials
Most of the materials supplied in the pump unit are suitable for recycling. Please conserve our natural resources and recycle these materials.
PRODUCT DESCRIPTION
Configuration
Pumps are offered in two models.
• Pentair Fairbanks Nijhuis ® 1650 close coupled
• Pentair Fairbanks Nijhuis 1620 frame mounted
Along with above mentioned models, pumps are also offered with following options required and mentioned by customer at the time of placing order.
• With or without flush line
• Oil lube bearings (frame mounted pumps only)
• Type 21 mechanical seal options (required for temperatures over
225˚F or 107.2˚C
Parts
Refer to “Assembly Exploded View” Figures 45 and 46 on Pages 23-24 for listing various parts.
Short Term Storage
The pump and equipment, as shipped, have adequate protection for short-term (up to three months) storage in a covered, dry, and ventilated location at the jobsite prior to installation.
• Dry pump internals and spray the liquid end with a water-displacement rust inhibitor.
• Apply a film of compatible lube oil over the water-displacement rust preventative.
• After the pump has been thoroughly drained, cover the pump suction and discharge flanges with full gasket material and blank off these openings with metal blank flanges and a minimum of four bolts. If mechanical seals have been used, then the annular opening between gland plate and shaft should be closed by a removable sealing ring supplied by the original equipment manufacturer to exclude airborne dust. Additionally, all connections in the seal cartridge must be plugged or sealed.
• All exposed painted surfaces should be dry, clean, and free of grease and other contaminants.
• The pump should be covered with a weather-resistant cover of waterproof paper or plastic to prohibit the build-up of dirt and dust accumulations.
Long Term Storage
All pumps are shop serviced and delivered in a ready to operate condition. If the pump after being delivered is not put into immediate operation, then proper care should be taken so that it operates without failure when put into service. The pump should be kept in a clean and dry area in a horizontal position. Ensure that the following precautions are taken for pumps being stored for more than three months.
• Pump surfaces which are machined and unpainted (e.g. flange ends, feet mounting etc.) and are easily subjected to corrosion must be protected by corrosion resistant coating.
• The pump shaft should be rotated once in a month to avoid locking of rotating assembly. This would also be helpful in uniform distribution of lubrication on bearings.
FM-03-536 (11/20/19)
5
PUMP INSTALLATION
INSTALLATION
Pump Location
• Pentair Fairbanks Nijhuis® 1600 End Suction pump must be installed horizontally.
• The pump should be located as close to the liquid source as possible so that the suction line can be short and direct.
See Figures 2 and 3 shown below.
• It should be located in a clean, open area, where it is easily accessible for inspection, disassembly and repair. Pumps installed in dark, dirty areas or in cramped locations are often neglected, which can result in premature failure of both the pump and the driver.
• Your pump should be located so that a hoist or crane can be used to move it without interference from piping. This factor is often overlooked in the advance planning stage.
• Install isolating valves on each side of pump so pump maintenance can be performed without draining the system.
• Special mounting requirements may be required if the pump is to be mounted near a noise or vibration sensitive area.
• The pump should be located in an area where moisture from condensation, can be adequately drained off. Moisture dripping on exposed metal or wood can cause rapid deterioration of the area.
Also wet floor produces safety hazards.
• Adequate provisions should be made for electrical wiring to the pump motor. A switch and overload protection should be installed near the pump if conditions permit. The electrical conduit should be positioned in such a way as to preclude the possibility of moisture entering the conduit or the motor, and causing short circuits.
• The installation must be evaluated to ensure that the net positive suction head available (NPSHA) meets or exceeds the limits as stated below:
• 2 ft for building services
• 5 ft for municipal application
• Outdoor installation will normally provide all of the above mentioned conditions. However, it is recommended to provide a weather shelter for your pump.
PIPE
HANGERS
DISCHARGE PIPING
DISCHARGE
TANK
DISCHARGE PIPING
GATE VALVE
CHECK VALVE
DISCHARGE
NOZZLE
LONG UNSUPPORTED
SUCTION PIPING
FOOT VALVE
STRAINER
Figure 3
Unsatisfactory location (Long indirect suction with no support)
Foundation
The foundation for your pump must be sufficiently rigid to absorb any vibration and stress encountered during pump operation. The mass of the foundation should be sufficient; preferably five times that of the pumping equipment, to form a permanent and rigid support for the baseplate.
A raised foundation of concrete is preferable for most floor mounted pumps. The raised foundation assures a satisfactory base, protects against flooding, simplifies moisture drainage, and facilitates keeping the area clean.
• Your pump should be firmly bolted to the foundation, whether it is a raised concrete base, steelwork wall, or structural member. The mounting bolts or lag screws should be accurately located per the applicable Pentair Fairbanks Nijhuis dimension sheet.
• Bolt sizing is critical particularly on high-pressure pumps, to adequately restrain reaction forces generated from directional flow change, system transients, and sudden valve closure.
BOLT OR
LAG SCREW
PUMP MOTOR
BASE
DISCHARGE
TANK
DISCHARGE
NOZZLE
GATE VALVE
CHECK VALVE
SUCTION NOZZLE
PIPE SUPPORT
DRIVER
THREADED
INSERT
CONCRETE
FOUNDATION
Figure 4
Typical close coupled pump mounting
Typical close coupled pump mounting
FLEXIBLE
COUPLING
POWER
FRAME
PUMP
SUCTION PIPING
FOOT VALVE
STRAINER
Figure 2
Recommended location
(Short direct suction)
PIPE
BASE
PLATE
6
FOUNDATION
BOLT
SHIMS
SHIMS
GROUTING CLEARANCE
CONCRETE
FOUNDATION
Figure 5
Typical flexible coupled pump mounting
Figure 5
Typical flexible coupled pump mounting FM-03-536 (11/20/19)
PUMP INSTALLATION
• Lag screws or bolts screwed into threaded inserts in the concrete are recommended for mounting close coupled pumps, rather than studs set into concrete (Figure 4 on Page 6). This permits removal of the drive motor without disturbing the pump liquid end or the piping.
• If a large pump is to be mounted on steelwork or other structure, adequate support should be provided to prevent deflection of the structure which could produce excessive strain on the pump casing and piping.
Setting the Pump
• Check the mounting surfaces of the pump unit and the foundation to make sure they are clean and free of obstructions. Set the pump on the foundation, being careful not to damage the foundation bolts or studs if used.
• Tighten the nuts or bolts finger tight.
NOTICE:
In close coupled pump assembly make sure the motor
(driver) and pump casing are grounded.
MOTOR
CASING
MOTOR
MOUNT
MOTOR GROUNDED ON BASE
WITH HELP OF MOTOR MOUNT
CASING GROUNDED
ON BASE
Figure 6
Setting a close coupled pump
Seismic Analysis
Figure 6
Setting a close coupled pump
Please consult factory if the pump is to be installed in seismic zones.
BASE PLATE
Leveling The Pump
Pump unit leveling can be done using the suction and discharge nozzles or flanges as reference points. Insertion of a shot piece of pipe in the threaded nozzles will facilitate use of a spirit level to determine whether or not the pump unit is leveled in all directions.
See Figure 7 shown below.
A spirit level can also be used on the machined faces of the suction and discharge flanges (Figure 8).
DISCHARGE SPIRIT LEVEL
SUCTION
Figure 8
Leveling with spirit level on pump flanges
Leveling the pump can require enough shims to support the base plate near the foundation bolts and at any points of the base plate carrying a substantial weight load. The shims should be large enough to allow a gap of 3/4" to 1-1/2" between the base plate and foundation for grouting.
NOTICE:
The pump base must be set level to avoid any mechanical difficulties with the pump or motor.
Pentair Fairbanks Nijhuis® 1620 pump was properly aligned, if supplied with a motor, at the factory. However, since the pump base is flexible, it may spring and twist during shipment. Do not pipe the pump until it is realigned. Realign the base after piping is completed and after the pump is grouted in and bolted down.
NOTICE:
It may be necessary to readjust the alignment from time to time while the unit and foundation are new. Realignment may prevent premature bearing failure, excessive vibration or shaft failure.
Ensure that proper hydronic accessories such as pressure relief valves, thermal expansion tanks and flow/pressure control devices are installed in the system. Consult the responsible party for your system to ensure these devices are installed and of the proper size.
Grouting the Installation
Grouting the base plate prevents lateral movement of the base plate, and improves the vibration absorbing characteristics of the foundation by increasing its mass. A wooden dam should be constructed around the base plate to contain the grout while it is being poured. The dam can be built tight against the base plate, or slightly removed from it as desired.
Refer to Figure 9 shown below.
The entire base plate should be completely filled with non-shrinkable type grout. The grout should be puddled frequently to remove any air bubbles from the grout.
SHORT PIPE
DISCHARGE
SPIRIT LEVEL
SOUPY GROUT
FOUNDATION BOLTS
ROLLED STEEL BASE
TWISTED
TENSION WIRE
SHORT PIPE
SUCTION
Figure 7
Leveling pump with spirit level and short lengths of pipe
FM-03-536 (11/20/19)
Figure 7
Leveling pump with spirit level and short lengths of pipe
SHIMS TO LEVEL
BASE PLATE
WOODEN DAM
ON BOTH SIDES
Figure 9
Grouting the base for frame mounted pumps
7
PUMP INSTALLATION
Piping and Connections
Inlet and outlet piping should be anchored, supported, and restrained near the pump to avoid application of forces and moments to the pump in excess. In calculating forces and moments, the weights of the pipe, internal thrust, contained fluid and insulation, as well as thermal expansion and contraction, should be considered. It is recommended that the first section of pipe be installed on the pump flange and then properly supported. Both the suction and discharge piping should be independently supported. The system piping should then be brought into alignment to the first section of pipe attached to the pump before completing the connections to the piping system.
To verify that there is no pipe strain and no piping loads being transmitted to the pump flanges, the flange connections are loosened and the alignment of the piping inspected. The piping to the pump inlet and outlet should be aligned to the pump flanges. The bolts should freely pass through flange with no binding. The alignment of the axis of the flanges should be within a tolerance of ½ the radial bolt clearance.
Faces of the flanges should be in alignment so that the dimensions between the faces indicate that they are parallel and allow for the insertion of the gasket.
Suction Piping
The suction piping should be short, but no less than ten pipe diameters in length, and direct with as few elbows and fittings as possible to keep head loss, from friction, at a minimum. However, the suction pipe should provide a minimum uninterrupted length, equal to ten pipe diameters, to the pump suction flange. A horizontal suction line should have a gradual rise to the pump, and pass under any interfering piping. See Figure 10 shown below.
TAPERED
ECCENTRIC
REDUCER
LONG
RADIUS
ELBOW
SUCTION
DISCHARGE
DISCHARGE
LONG
UNSUPPORTED
PIPING
TAPERED
ECCENTRIC
REDUCER
EXCESSIVE
NUMBER OF
ELBOWS
EXCESSIVE
LIFT
Figure 12
Unsatisfactory suction lift piping (Long and indirect with no support)
Pipe
The suction pipe diameter should be at least the same diameter as the suction nozzle on the pump, and preferably larger. Use of a smaller diameter pipe will result in loss of head due to friction. All joints must be tight to maintain prime on the pump.
TAPERED
ECCENTRIC
REDUCER
DISCHARGE
SUPPLY
TANK
NO SUPPORT
EXCESSIVE
NUMBER OF
ELBOWS
8
FOOT VALVE
STRAINER
Figure 10
Recommended suction lift piping (Short and direct)
Recommended suction lift piping
(Short and direct) position for illustration purposes only
SUPPLY
TANK
DISCHARGE
GATE
VALVE
SUCTION
PIPING
TAPERED
ECCENTRIC
REDUCER
PIPE SUPPORT
SUCTION
Figure 13
Unsatisfactory flooded suction piping (Long and indirect with no support)
PIPE HANGERS
DISCHARGE
PIPING
SUCTION
PIPING
DISCHARGE
TANK
PIPE SUPPORTS
Figure 14
Figure 14
Supporting piping
Elbows
Long radius elbows should be used in place of standard elbows wherever possible, because of their superior flow characteristics. For instance, head loss in a standard four inch elbow is equivalent to the head loss in a piece of pipe 11 feet long, while the head loss in a long radius elbow is approximately half as much. Elbows should not be used at the suction
FM-03-536 (11/20/19)
PUMP INSTALLATION
nozzle, but if it is unavoidable, they should be installed in a vertical position. Elbows installed in any position at the suction nozzle have a tendency to distribute the liquid unevenly in the impeller chamber, causing a reduction in capacity, and creating an undesirable thrust condition. See Figures 15, 16A, and 16B shown below.
DISCHARGE
SUCTION
ECCENTRIC
TAPERED
REDUCER
AIR
SHORT RADIUS
LONG RADIUS
The friction loss in a long radius elbow is approximately one-half the friction loss of a short radius elbow.
FIgure 15
Long versus short radius elbows
Long versus short radius elbows
DISCHARGE
INCORRECT
Figure 17B
Incorrect Installation of eccentric tapered reducers
SUCTION
INCORRECT
CORRECT
PUMP
SUCTION
Spacer between suction and elbow permits equal flow of water to each side of double suction impeller, prevents excessive thrust and resulting wear on bearings, etc.
Figure 18
Reducer between elbow and pump suction nozzle
Discharge Piping
Figure 18
Reducer between elbow and Pump suction nozzle
Discharge piping should also be short and direct as possible, with few elbows and fittings, to reduce head loss from friction.
See Figures 19 and 20 shown below.
Figure 16A
Correct elbow installation on suction nozzle
Figure 16A
SUCTION
Figure 16B
Incorrect elbow installation on suction nozzle
Reducers
Eccentric reducers should be installed directly at the suction nozzle, with the taper at the bottom to prevent air pockets from forming.
Straight taper reducers should never be used in a horizontal suction line because of the air pocket that is formed at the leg of the reducer and the pipe. See Figures 17A, 17B, and 18 shown below.
DISCHARGE
SUCTION
ECCENTRIC
TAPERED
REDUCER
DISCHARGE
TANK
CHECK
VALVE
GATE VALVE
INCREASER
DISCHARGE
PIPING
SUCTION
Figure 19
Figure 19
Unsatisfactory discharge piping
(Long with excessive elbows and joints)
EXCESSIVE
NUMBER OF
ELBOWS
DISCHARGE
PIPING
GATE VALVE
CHECK VALVE
CORRECT
Figure 17A
Figure 17A
ELBOW
DISCHARGE
TANK
SUCTION
Figure 20
(Short and direct)
(Short and direct)
FM-03-536 (11/20/19)
9
PUMP INSTALLATION
Pipe
The discharge pipe diameter should be the same as, or larger than, the discharge nozzle diameter. The size of discharge pipe to be used is dependent upon the application. The recommended pipe diameter can be obtained from your nearest Pentair Fairbanks Nijhuis ® authorized distributor or Customer Service.
Reducers and Increasers
An increaser should be installed at the discharge nozzle if larger diameter discharge piping is used. Straight taper increasers and/ or reducers are satisfactory in discharge piping, because air pockets on the discharge side do not affect pump efficiency. See Figure 21 below.
friction loss in the foot valve is high. Install check and foot valve as indicated by arrow to ensure proper installation.
Flooded Suction:
When the liquid source is above the pump centerline, a flooded suction condition exists and a gate valve is required to shut off the liquid supply for pump inspection and maintenance. The gate valve should be installed with the stem in a horizontal or downward position to prevent formation of an air pocket in the valve.
DISCHARGE
PIPE SUPPORT
INCREASER
SUCTION PIPING
SUCTION
DISCHARGE
ECCENTRIC
TAPERED
REDUCER
Figure 21
Reducer and increaser installation
Valves
Valves are an important part of your installation. They facilitate priming of the pump, and control the volume of the pumped liquid.
Foot Valves
OUTLET
FOOT VALVE
STRAINER
Figure 23
Foot valve installed with screen
Foot valve installed with screen
Discharge Valves
The discharge piping should include a check valve and a gate valve. The check valve should be located between the gate valve and the pump.
If an increaser is used in the discharge piping, the increaser should be installed between the pump nozzle and the check valve. The check valve protects against a reverse flow of the liquid if the driver fails. See Figure
24 shown below.
GATE VALVE
CHECK VALVE
DISCHARGE
PIPING
VALVES
SUCTION
INLET PORTS
Figure 22
Foot valve
Suction Lift:
In suction lift applications where the suction lift is low, a foot valve can be installed to maintain the prime of the pump. A foot valve is essentially a check valve, allowing flow in one direction only, towards the pump. When the pump is shut down, the pressure of the liquid returning to the well causes the valve to close, retaining the liquid in the suction line.
A slow closing check valve should be installed when the static discharge head is high. A foot valve should not be used under these conditions, as failure of the driver would allow the water to rush back rapidly thus causing a heavy water hammer.
Foot valves, when used, should be the flat type rather than multiple spring type. The valve should have a large inlet area, because the
10
FM-03-536 (11/20/19)
PUMP INSTALLATION
Air Vent Valves
Vent valves are installed at the high points in the pump casing to allow air or vapor to escape. These valves are used to release trapped air from the pump casing during priming and when pump becomes air bound. See
Figure 25 shown below.
AIR VENT
VALVE / PLUG
DISCHARGE
DISCHARGE
BELLOWS TYPE
EXPANSION JOINT
PIPE
SUPPORTS
Figure 27
SUCTION
Figure 25
Figure 25
Air vent valve or plug
Expansion Joints
Expansion joints are used primarily to prevent transmission of piping strain, caused by thermal expansion and contraction, piping misalignment, pressure changes, or other causes, to the pump casing.
They are also used to suppress any noise that may be transmitted through the piping. It is recommended that the flexible metal type of expansion joint be used because rubber expansion joints, have a tendency to deteriorate, making frequent replacement necessary.
If an expansion joint is used, an anchor or a restraining device should be installed between the joint and the pump to prevent objectionable forces from being transmitted to the pump. If an anchor is not installed at this point, a force equal to the area of the expansion joint times the pressure in the pipe is developed and transmitted to the pump. This force may exceed the allowable flange loading and could result in damage to the pump or piping. See Figures 26 and 27 shown below.
PIPE
SUPPORT
FM-03-536 (11/20/19)
BELLOWS TYPE
EXPANSION
JOINT
SUCTION
DISCHARGE
Figure 26
Expansion joint in suction line
It is important to remove foreign matter that can clog the pump and impair its capacity, or stop it completely. Small particles such as sand, dirt, scale from inside pipe and other extraneous materials can get into the close clearance parts of the pump and cause considerable damage to the parts.
Strainers should be selected to have a total area of holes equal to at least four times the suction pipe area.
In applications where stick, twigs, leaves and other large debris are present, a larger outside screen should be placed around the suction inlet to prevent choking of the strainer. This screen should have sufficient openings so that flow velocity does not exceed two feet per second.
ALIGNMENT
General Alignment
Pumps and drivers received from the factory with both machines mounted on a common baseplate are aligned or checked for alignment before shipment. All baseplates are flexible to some extent and, therefore, must not be relied on to maintain the factory alignment.
Realignment is necessary after the complete unit has been leveled, the grout has set, foundation bolts have been tightened and the piping has filled with fluid. The alignment must be rechecked after the unit is piped and rechecked periodically.
SHAFT/COUPLING ALIGNMENT
Initial Alignment of Flexible Coupling
A flexible coupling is used to compensate for minor misalignment of the pump and driver shaft and is limited to misalignment due to minor temperature changes.
The pump and driver were accurately aligned at the factory. However, alignment cannot be maintained during shipping and handling.
Therefore it will be necessary for you to realign the pump and driver.
Flexible couplings are not universal joints. They should not be used to compensate for misalignment of the pump and motor shafts.
Their function is to transmit power from the driver to the pump while compensating for thermal expansion and shaft end movement. The coupling faces should be far enough apart so that they do not make contact when the motor shaft is forced to the limit of the bearing clearance toward the pump shaft.
In order to properly align the coupling, you will need a taper gauge or set of feeler gauges, and a straight edge.
There are two types of misalignment encountered with flexible couplings: angular misalignment, in which the shafts are not parallel, and parallel misalignment where the shafts are parallel but not on the same axis.
11
PUMP INSTALLATION
To check angular alignment, insert a feeler gauge or taper gauge at any four places 90° apart around the coupling halves. Insert shims under the driver feet until the same reading is obtained at all four check points.
The pump and driver will then be in angular alignment.
To check parallel alignment, a straight edge should be held against the edges of the coupling halves at any four places 90° apart around the coupling. The straight edge should be parallel to the pump and driver shafts at all times. Insert shims until the straight edge lies flat against both coupling halves at all four checkpoints. The pump and driver will then be in proper parallel alignment. For more detailed alignment information consult the coupling manufacturer's installation instructions. Refer to Figure 28 shown below.
STRAIGHT EDGE
Pipe Alignment
Proper piping alignment is essential before connection is made. Piping alignment should never be achieved by force, as this could produce strain on the piping and the pump casing. Proper supports should be installed for the piping to keep its weight off the pump casing.
When flange bolts are used, line up the piping first, then loosely install flange bolts. Check the piping alignment, and tighten the flange bolts until all bolts are tightened securely. See Figure 29 shown below.
MISALIGNMENT
FLANGE
BOLTS
INCORRECT
FLANGE
BOLTS
WEDGE OR
THICKNESS GAUGE
PARALLEL
MISALIGNMENT
ANGULAR
MISALIGNMENT
Figure 28
Flexible coupling alignment piping
PERFECT
ALIGNMENT
For Fine Alignment, 3500 RPM Operation, For All Other Coupler Types
A dial indicator should be used when greater alignment accuracy is required. Use the following alignment tolerances unless specified otherwise by the coupling manufacturer. On sleeve type couplings make sure there is at least 1/8" end clearance between the sleeve and the two coupling halves.
To check angular misalignments, mount the dial indicator base to the coupling half, and position the dial indicator button on the front or rear face of the opposite coupling half. Set the dial to zero, rotate both coupling halves together, making sure the indicator button always indicates off the same spot. Misalignment values within 0.004 inches
TIR per inch of coupler radius is permissible.
To check parallel misalignment, mount the dial indicator base to one coupling half, or shaft and position the dial indicator button on the outside diameter of the opposite coupling half. Set the dial to zero.
Rotate both coupling halves together, making sure the indicator button always indicates off the same spot. Misalignment within 0.004 inches
TIR is permissible.
PROPER NATURAL
ALIGNMENT
CORRECT
Figure 29
Pipe alignment
Air in Piping
One of the most common conditions affecting pump efficiency is the formation of air pockets in the suction line. The air pockets are a result of high points and improper installation of elbows, reducers, and valves in the suction piping. See Figures 30 and 31 shown below and on next page.
The pump seal depend on the liquid being pumped for lubrication with resultant damage to them.
DISCHARGE
STRAIGHT
TAPER REDUCER AIR POCKET
INCORRECT
SUCTION
DISCHARGE
ECCENTRIC
TAPER REDUCER
SUCTION
CORRECT
Figure 30
Air pocket in reducer
Air pocket in reducer
12
FM-03-536 (11/20/19)
PUMP OPERATION
DISCHARGE
DISCHARGE
AIR POCKET
SUCTION
INCORRECT
SUCTION
CORRECT
ECCENTRIC TAPER
REDUCER
Figure 31
Air pocket in elbow
AIR POCKET
INCORRECT
CORRECT
Figure 32
DECREASER
ELBOW
ELBOW sufficiently submerged to prevent exposure of the end of the pipe when the well is at its minimum level and to prevent vortex action (whirlpool effect) of the liquid at the suction pipe, which will draw air into the pipe.
Also, care should be taken to keep the suction pipe located away from the well inlet since the incoming liquid may be carrying air bubbles.
Another cause of air in the liquid is dropping of the liquid from too high a point into the well. See Figure 32 shown above.
Electrical Wiring
Normally, your pump will be supplied with an attached drive motor. The motor should be wired in accordance with the wiring diagram found on the motor nameplate. Be sure the voltage, frequency, and phase of your power supply corresponds with the nameplate data. It is recommended to provide a separate switch and overload protection for your pump motor to protect against power failure in some other area. Conversely, if the pump motor develops electrical problems, it will be isolated from other equipment.
Notice:
PRESTARTING INSTRUCTION: The coupling halves should be connected. Prior to connection, however, the drive motor should be started to make sure the direction of rotation is the same as the direction indicated by the arrow on the pump casing.
COMMISSIONING, START-UP, OPERATION, AND SHUTDOWN
Lubrication
In dry locations, each bearing will need lubrication at least after every
4,000 hours of running time or 6 to 12 months, whichever is more frequent. In wet locations (exposed to dripping water, to the weather or to heavy condensation found in unheated or poorly ventilated underground locations) every 2,000 hours or every 3 to 6 months, whichever is more frequent. Applicable to 1620 series pumps.
• Use Chevron
®
SRI Grease NLGI grade 2.
Before running the driver, either separately or connected to the pump, check lubrication and cooling requirements.
Proper lubrication is critical for trouble-free, long-term operation of the equipment. Lubrication methods and frequency vary with bearing type, application, environment, and the unique operating characteristics of the individual piece of equipment. Ensure lubrication is present and lubrication systems are connected and operational per instructions.
Rotation
Pump rotation is clockwise when viewed from the back of the motor.
An arrow is also located on the pump casing to show the direction of rotation.
It is absolutely essential that the rotation of the motor be checked before connecting the shaft coupling. Incorrect rotation of the pump, for even a short time, can dislodge and damage the impeller, casing, shaft, and shaft seal.
Guarding
All guards must be in place and secure per the instructions prior to start-up.
Guards must not be removed while the pump is operational. Always follow lock out – tag out procedures when working on equipment that may turn on.
START-UP CONSIDERATIONS
System Flushing
When the pump is installed in the completed piping system, it is recommended that the system be flushed to remove debris such as stubs of welding rod, welding slag, and loose scale. The pump manufacturer should be consulted as to the suitability of any chemical flush additives added to the system.
Priming and Filling
The pump should not run unless it is completely filled with liquid as there is danger of damaging some of the pump components. This includes short runs for rotation verification. The pump will not operate satisfactorily until it is primed. All air must be expelled from the suction piping and pump casing, and replaced by the liquid to be pumped. There are several methods of priming pumps. The one you select will depend on your specific requirements.
Flooded Suction Priming
This method of priming a pump is relatively simple. The liquid source is located above the pump, and all that is necessary to prime the pump is to open the air vent valve or plug in the pump casing, and to crack the gate valve in the suction line. The suction line and pump should be filled
FM-03-536 (11/20/19)
13
PUMP OPERATION
slowly until a steady stream of liquid is observed flowing from the air vent. After your pump is operating, it is recommended that the air vent valve or plug be opened again to ensure that all air has been expelled from the pump casing. See Figure 33 on shown below.
LIQUID
SUPPLY
DISCHARGE
AIR VENT
OPENING
GATE VALVE
DISCHARGE
SUCTION
SUCTION
Foot Valve Priming
Figure 33
Flooded suction priming
Figure 33
Flooded suction priming
OUTLET
Priming by hand
A priming line can also be inserted in the discharge piping between the check valve and the pump, or the priming can be done with a bucket and funnel. Refer to Figure 35 shown above. It is important to completely fill the suction pipe and pump casing with liquid. When the pump is started, the vacuum created by pumping the priming fluid, combined with atmospheric pressure in the liquid well, forces liquid into the suction piping, thus opening the valve and keeping it open until the pump is shut down. When the pump is shut down, the liquid being pumped reverses its flow causing the valve to close. The liquid is now trapped in the suction piping and pump casing, thus maintaining a prime on the pump.
VALVES
INLET PORTS
Figure 34
Foot valve cutaway
A foot valve can be used for priming on suction lift applications. The foot valve located at the bottom end or foot of the suction piping, functions as a check valve which allows flow in one direction only toward the pump.
Initial priming is accomplished by completely filling the suction piping and pump casing with the liquid to be pumped. This can be done by removing the air vent valve or plug at the top of the pump casing, and inserting a pipe nipple in the orifice with an appropriate increaser to accommodate a hose connection.
Vacuum Priming
Vacuum priming consists of removing air from the pump casing and suction piping, and drawing liquid into them by means of a vacuum creating device. The types of vacuum equipment range from a simple hand pump to complex central priming systems. Your specific priming requirements will govern what type of vacuum primer you use.
Air Ejector
One type of vacuum primer is the air ejector. If liquid under pressure or steam is available, an ejector can be used. The ejector is connected to the air vent orifice. A stream of the ejecting medium is passed through the ejector creating a vacuum in the ejector, and drawing air from the pump casing and suction piping. When liquid flows steadily from the ejector discharge pipe, the pump is primed. See Figure 36 shown below.
GATE
VALVES
DISCHARGE
EJECTOR
SUCTION
LIQUID
SUPPLY
FOOT VALVE
(OPTIONAL)
Figure 36
Priming by ejector
14
FM-03-536 (11/20/19)
PUMP OPERATION
DISCHARGE
SPINDLE
AIR VENT
SUCTION
PRESSURE LINE
AIR
INLET
FROM
PUMP
STEAM INLET
STEAM AND AIR
DISCHARGE
LIQUID
SUPPLY
PRIMING
INDUCTOR
NOZZLE
Figure 37
(Ejector cutaway)
Vacuum Pumps
Rotary or reciprocating pumps are frequently used as vacuum pumps.
They fall into two categories, wet-vacuum and dry-vacuum. The principle of operation is essentially the same, however, the dry-vacuum pump cannot accommodate a liquid and air mixture, while the wetvacuum pump can accommodate liquid, air, or a combination of both.
Vacuum pumps can be installed as part of a central priming system servicing many pumps, as an automatic priming system, or as a manually controlled independently driven pump.
AIR RELEASE - FLOAT
CONTROLS VALVE WHICH
PERMITS AIR TO PASS, BUT
CLOSES WHEN WATER
CHAMBER FILLS.
GATE VALVE
CENTRIFUGAL
PUMP
SUCTION
DISCHARGE
SEALING
WATER
VALVES
VACUUM
PUMP
AIR
DISCHARGE
Figure 39
Figure 39
Inductor priming
SHAFT SEALING SETTINGS AND ADJUSTMENTS
Mechanical Seals
A mechanical seal consists of a rotating element and a stationary element. The sealing faces are highly lapped surfaces on materials selected for their low coefficient of friction and their resistance to corrosion by the liquid being pumped. The faces run with a very thin film of liquid between them. In addition, there must be a means of loading the seal. This is accomplished either with a spring (or springs) or with an elastomeric or metallic flexible member.
Mechanical seals are made in a wide variety of designs; therefore the instructions for the specific seal must be carefully studied and followed.
A mechanical seal is a precision device and must be treated accordingly.
Mechanical seals normally require no adjustment during operation.
Except for slight initial leakage, the seal should operate with negligible leakage.
Mechanical seals should not run dry unless allowed by the manufacturer. Seals require a continuous supply of flush and/or cooling fluid.
Figure 38
Vacuum pump priming
The suction piping of the vacuum pump is connected to the air vent orifice on the pump to be primed. The vacuum produced by the vacuum pump removes air from the turbine pump suction piping and casing, and draws liquid from the liquid well into the turbine pump. Dry-vacuum pumps must be installed so that no liquid is taken into the air pump.
Installation of a water trap or use of a vacuum tank is recommended for dry-vacuum pumps. Refer to Figure 38 shown above.
Inductor Priming
On suction lift applications it may be desirable to prime your pump with a priming inductor. This type of primer is comprised of a liquid nozzle and an inductor at the foot end of the suction piping. The nozzle and inductor are connected to a high pressure liquid supply such as a city water service. The pump is primed by opening the valve in the pressure line.
This will allow the liquid to flow through the nozzle and into the inductor.
The velocity of the high pressure liquid drives the liquid into the suction piping and up to the pump, thus completing the priming operation. Refer to Figure 39.
START-UP, OPERATION, AND SHUTDOWN
Valve Setting at Start-up
Position of Discharge Gate Valve When Starting
The discharge gate valve should be partially closed when a high or medium head centrifugal pump is started, because this type of pump requires much less power with the gate valve closed, than when it is operated at rated capacity and head with the discharge gate valve open. As soon as the pump is up to operating speed, the discharge gate valve should be opened to the desired position.
Position of Suction Piping Gate Valve When Starting
In flooded suction applications, the gate valve is opened at the time the pump is being primed, and will remain open for starting and operation.
The pump should not be operated with the inlet or outlet valves closed. The operation of a pump with the inlet valve closed may cause serious damage and should not be attempted. Operation with both inlet and outlet valves closed for even brief periods of time is an unacceptable and dangerous practice.
FM-03-536 (11/20/19)
15
PUMP MAINTENANCE AND SERVICE
Operation
The following points must be ensured before starting the pump:
1. The current supply agrees with the voltage and frequency on the motor nameplate.
2. The motor is wired for correct voltage.
3. The thermal overload relays are correct size and set for operation.
4. The pump is fully primed. Flood the casing and seal area with liquid to release the air out of pump through flush line and air vent valve near discharge flange. Priming must be continued until air is completely removed. This is indicated by continuous flow of liquid through flush line and air vent. Disconnect power to the motor and lock-out / tag-out the power source prior to rotating the shaft by hand. a. Failure to flood the seal area with water may cause seal failure due to lack of lubrication.
5. Jog the motor to check that the motor rotates clockwise, as indicated by the arrow on the pump casing.
6. Coupling guard must be in its appropriate position on account of human safety.
Starting Up
1. Start the pump with the discharge valve slightly open and verify that the pump is operating smoothly and is not rubbing.
2. Start opening the discharge valve gradually.
Notice:
Do not run the pump for extended period with discharge valve closed, so as to avoid overheating and potential damaging loads.
3. If the pump is equipped with a circulation relief valve, such valve prevents overheating when the pump is operating at reduced capacity.
4. Stop the pump immediately if any of the following situations arise: a. No/insufficient liquid. b. Inadequate discharge pressure. c. Loss of suction pressure. d. High power consumption.
e. Noisy operation and/or high vibration after discharge valve is in an open position.
Check the manual for troubleshooting the cause. See Pages 21 -
22.
Shut Down
It is recommended to close the discharge valve before stopping the pump to avoid any water hammer effect. However, this practice is not mandatory and pump may be stopped with discharge valve open in case an emergency.
MAINTENANCE AND SERVICE
Schedule
Preventive maintenance and routine check-ups may prevent the pump from major failures. An inspection & maintenance log should be kept and the inspector is to immediately report any problems. Pump should be checked on regular basis for any unusual noise, vibrations and abnormal rise of temperature. If equipped with a sight flow indicator, check it from time to time for fluid flow and if no flow is observed, replace the filter or check the separator. A suggested guide for preventive maintenance for normal application is given below in Table 1:
Table 1
Guide for preventive maintenance
ITEMS
Vibration
Bolting
ACTION REQUIRED
Check for change in vibration levels
Check for proper bolt torque
FREQUENCY
Refer to ANSI/HI 9.6.5
Condition Monitoring
Annually
Mechanical Seals Monitor seal leakage
Refer to ANSI/HI 9.6.5
Condition Monitoring
Pump/Motor
Alignment
Check for change in alignment
Annually
Surface
Inspection
Check for coating integrity or signs of corrosion
Wear and running clearance
Inspect and measure
Exterior components:
Quarterly
Interior components:
Annually
Annually or as determined by service condition when performance decreases are noted or as recommended
No flow in sight flow indicator
(if installed)
Replace filter, Inspect separator
Controls and accessories
General site conditions
Inspect for damage, proper function and condition
Inspect for damage, proper function and condition
Daily
Annually
150 hours of operation as necessary
Preferred shutdown sequence is as follows:
1. Preferably close the discharge valve first.
2. Then turn off the motor.
3. Now, close the suction line valve.
4. Drain the pump liquid completely, if pump to be kept nonoperational for longer period or if there is danger of freezing.
5. If it is necessary for the pump to maintain its prime while it is shutdown, it is recommended to install either a foot valve or a check valve in the suction piping.
16
FM-03-536 (11/20/19)
PUMP MAINTENANCE AND SERVICE
Cold Weather Maintenance
When handling water or other liquids that may freeze at low temperatures, care should be taken to prevent the pump from freezing during cold weather when the pump is not in operation. It may be necessary to drain the pump casing during shutdown periods by removing the bottom drain plug.
Mechanical Seal Maintenance
The mechanical seal require flushing which is flushed from discharge of the pump through a flush line. A throttle bush isolates the mechanical seal from the liquid in the pump. Since mechanical seals need a film of liquid between the sealing faces, pump must not be run unless properly filled with liquid for intended operation.
A ‘weep’ sound may be heard from mechanical seals at start-up. The pump should run for approximately 8-10 hours, which is the break-in period for seal. During this operation the mechanical seal would ‘seat’ properly.
Pentair Fairbanks Nijhuis® 1600 pumps are supplied with type 21 mechanical seal.
FLEXIBLE CUP
STATIONARY SEAT
ROTATING HEAD
SPRING
SPRING RETAINER
Table 2
Pentair Fairbanks Nijhuis 1620 pumps seal kit selection matrix
IMPELLER
SIZE
1
POWER FRAME
NO.
POWER FRAME
PART NO.
SEAL KIT NO.
7" PUMPS
ALL 9.5"
PUMPS
EXCEPT
6" 1621
6" 1621
11" PUMPS
1
2
3
21A
1
2
3
21A
1
2
3
21A
1
2
3
21A
3550006644
3550008644
3550009644
NA
3550006644
3550008644
3550009644
NA
NA
3550008644
3550009644
NA
3550006644
3550008644
3550009644
3550300644
4761251644
4761252644
4761252644
NA
4761254644
4761255644
4761255644
NA
NA
4761256644
4761256644
NA
4761257644
4761258644
4761258644
4761260644
1-1/2" 1623
13.5" PUMPS
2
3
1
1 3550006644
NA
3550008644
3550009644
4761261644
NA
4761263644
4761263644
21A 3550300644 4761264644
1
7", 9.5", 11" and 13.5" denote maximum impeller diameter of the pump. Refer to the
Table for Pump - Impeller Size Relation on page 26 to identify the pump model.
Figure 40
Figure 40
Recommended Spare Part List
Although all the components could be procured by the customer at short interval, to reduce downtime the below mentioned components should be kept handy in case the pump is to be shut down for maintenance. The components are:
• Mechanical seal
• Wear rings
• Gaskets, O-rings, seals
Notice:
Refer to Table 2 before ordering seal kit corresponding to power frame numbers in case of Pentair Fairbanks Nijhuis 1620 pumps.
Consumables
Following items are of regular use during preventive and accidental maintenance and must be kept in stock by the customer.
• Lubricants
• Cleaning materials
• Touch up coating
Tools and Fixtures
Pump assembly and disassembly can be performed by using standard hand tools available in market. For quick reference, tools required for disassembly of various pump components are mentioned below in
Table 3 on the next page.
FM-03-536 (11/20/19)
17
PUMP MAINTENANCE AND SERVICE
Table 3
Quick reference for tools and fixtures
ITEM
NO.
#4 &
#4A
MOTOR FRAME
ALL
PUMPS
ALL
#5 ALL
7”
9.5”,11”
13.5"
#5B
143-184
213-215
254-256
284-326
364-405
444-449
9.5", 11", 12", 13.5"
9.5", 11", 12", 13.5"
9.5", 11", 13.5"
9.5", 11", 13.5"
9.5"
9.5"
143-215 7", 9.5", 11", 13.5"
#9
#32
254-326
364-449
143-184
213-215
254-256
284-326
364-405
444-449 TCZ
7", 9.5", 11", 13.5"
7", 9.5"
7", 9.5", 11", 13.5"
7", 9.5", 11", 13.5"
WRENCH SIZE AND
TYPE
9/16" wrench
9/16” wrench
3/4” wrench
1-1/2” wrench
9/16” wrench
3/4” wrench
9/16 “ socket wrench
3/4” socket wrench
9/16” wrench
3/4” wrench
1-1/2” wrench
In addition to the above mentioned tools some additional equipment & fixtures may be required which are mentioned below:
• Lifting devices (crane, hoist, lifting chains or straps)
• Impeller puller (to remove pressed-on impeller from shaft)
• Torch (to heat parts to aid in removal)
• Die grinder (to cut out wear rings or shaft sleeves, if needed)
• Work table or fixture for holding pump
• Measuring equipment (feeler gauges, dial indicator, etc.)
• Bearing puller (to remove pressed on bearings from shaft)
• Hot oil bath (or method to heat bearings and coupling hubs for installation)
Fastener Torque and Sequence
Proper tightening of bolting is very important. Torque values will vary depending on the size and grade of bolting used. Torque values for coupling bolts and grub screws and sequence of their tightening are mentioned in the following section for replacement procedure of mechanical seals. Tightening torques for common bolt diameter can be found in Table 4 below.
Table 4
Cap screw torque for common bolt diameters
CAPSCREW
TYPE
HEAD
MARKING IN-POUNDS
FOOT-POUNDS
1/4" 5/16" 3/8" 7/16" 1/2" 5/8" 3/4"
SAE GRADE 5
REPAIRS
85 180 27 43 65 130 230
Notice:
READ AND UNDERSTAND ALL SAFETY WARNINGS AT THE
BEGINNING OF THE MANUAL BEFORE BEGINNING INSTALLATION OR
ANY REPAIR WORK
This repairs section is broken into two major parts. The first part covers the dismantling of the mechanical seal, power frame disassembly and complete pump disassembly. The second part covers installation of mechanical seal, power frame reassembly and complete pump assembly. Refer to the exploded pump diagram (Figures 45 and 46 on
Pages 23-24) for item numbers.
Complete Pump Disassembly - Pentair Fairbanks Nijhuis® Model
1620/1650
SUDDEN START-UP HAZARD.
Disconnect and lock out power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage.
1. Ensure the electrical power is locked out, the system pressure has been lowered and temperature of the unit is at a safe level.
2. Isolate the pump from the system by closing the valves that should be located on the suction and discharge side of the pump.
3. Loosen pipe plug and drain the pump.
4. Remove all relief, cooling, flushing, or drain lines from the pump.
Break suction and discharge connections only if it is desired to remove casing (#6).
Hot surface hazard:
If pumping hot water, ensure guards or proper insulation is installed to protect against skin contact to hot piping or pump components. Failure to follow these instructions could result in serious personal injury, death or property damage.
High pressure hazard:
All pumps are designed for specific maximum working pressure. Do not exceed this pressure.
Install properly sized pressure relief valves in system. Failure to follow these instructions could result in serious personal injury, death or property damage.
Spraying water hazard:
When servicing pump replace all gaskets and seals. Do not reuse old gaskets or seals.
Failure to follow these instructions could result in serious personal injury, death or property damage.
Notice:
For Pentair Fairbanks Nijhuis 1620 complete pump disassembly continue with step 5, For Pentair Fairbanks Nijhuis 1650 complete pump disassembly proceed to step 7 on the next page.
5. For Pentair Fairbanks Nijhuis 1620 pumps, remove the coupling guard.
6. For Pentair Fairbanks Nijhuis 1620 pumps, loosen the set screws in both coupling halves and slide each half back as far as possible on its shaft. Then, remove the coupling insert. See Figure 41 shown on next page.
18
FM-03-536 (11/20/19)
PUMP MAINTENANCE AND SERVICE
REMOVE INSERT
FROM COUPLING
SLIDE COUPLING HALF
AS FAR AS POSSIBLE
Figure 41
3804 - frame mounted pump assembly
7. Remove the foot support cap screws of power frame (for 1620)/ motor (for 1650).
8. Loosen the casing cap screws (#5) connecting the seal plate (#35A).
Do not remove them. Utilize two casing bolts to jack the power frame assembly (for 1620)/ motor assembly (for 1650) out from the casing (#6).
9. Utilize suitable lifting equipment to lift the power frame assembly
(for 1620)/ motor assembly (for 1650) out from the casing.
10. Remove impeller (#11).
11. Remove impeller key (#12).
12. Slide sleeve (#25) and O-ring (#10) with the rotating parts of the mechanical seal (Refer Figure 42) from the shaft. See Figure 43.
ROTATING HEAD
SPRING
SLEEVE REMOVED WITH ROTATING PART
OF MECHANICAL SEAL
Figure 43 seal plate (#35A) if any repair is required or for ease of replacing mechanical seal.
14. The seal flexible cup and stationary seat should be pressed out of the seal plate and the cavity cleaned of all residues. Make sure that the seal cavity is not damaged during disassembly since sharp edge can easily damage the elastomer on the mechanical seal during reassembly.
The mechanical seal is a precision product and must be treated as such. During removal, great care must be taken to avoid dropping any part of the seal. Take particular care not to scratch the lapped faces on the washer or the sealing seat. Do not put a seal back into service until the sealing faces of the washer and the seat have been lapped or replaced.
Notice:
The sleeve should be carefully cleaned to remove any residue that may be remaining in the seal area. The rubber in the seal may have been partially adhered to the sleeve. The sleeve must also be checked for abrasion or corrosion that can occur when fluid residue penetrates between the seal and the sleeve. The sleeve under the seal may be polished lightly to a 32 RMS finish before reassembly. Do not reuse a pitted sleeve. Pin may be removed if necessary.
SPRING RETAINER
Figure 42
Figure 42
Rotating parts of mechanical seal
Rotating parts of mechanical seal
STATIONARY PART OF
MECHANICAL SEAL
PRESSED INSIDE THE
SEAL PLATE
STATIONARY SEAL
Figure 44
If only mechanical seal is to be replaced, stop at this point and
Nijhuis 1620 complete pump disassembly.
FM-03-536 (11/20/19)
19
PUMP MAINTENANCE AND SERVICE
Pentair Fairbanks Nijhuis® 1620 Complete Pump Disassembly or
Power Frame Disassembly
Notice:
Read and understand all safety warnings at the beginning of the manual before beginning installation or any repair work.
15. Remove the seal plate (#35A) cap screws (#5B) from the bracket
(#35B).
16. Remove the power frame cap screws (#5) and washers (#5A) from the bracket (#35B).
If the power frame assembly is being replaced, skip to section titled
“Power Frame Reassembly”. If replacing the shaft (#55), continue with step 18 for shaft disassembly.
17. Remove the grease fittings (#43) from the power frame.
18. Unscrew cap screws (#48) and remove bearing cap (#49). Remove
O-ring (oil lubed only) and retainer ring (#52).
19. Slide out shaft (#55), bearings (#53 and #54). Since bearings (#53 and #54) are press fitted on the shaft, they will have to be pulled or pressed off the shaft. Remove grease seals (#51 & #51A) from frame
(#57) and bearing cap (#49) respectively
20. Thoroughly clean the shaft (#55), removing any oil or dirt.
Inspection
Once the pumping unit is disassembled, component parts should be inspected to determine their condition. Ball bearings that turn roughly or show wear should be replaced. Cracked castings should never be used. Scored or worn pump shaft should be replaced. Gaskets should be replaced at reassembly for efficiency. It is recommended to replace routinely than to replace singly as the need arises.
Complete Pump Reassembly - Model 1620/1650
To install mechanical seal skip to step 8 under section “Installation of the
Mechanical Seal-1650-1620 Pumps". Otherwise continue with step 1 for
“Complete Pump Reassembly - Model 1620/1650”.
Power Frame Reassembly
Reassembly will generally be in reverse order of disassembly. If disassembly was not complete, use only those steps related to your particular repair program.
1. Press grease seals (#51 & 51A) into frame (#57) and bearing cap (#49) respectively.
2. Press bearings (#53 & #54) onto shaft (#55).
3. Snap retainer ring (#52) into place.
4. Slide shaft (#55) and bearings (#53 & #54) into frame (#57).
5. Fasten bearing cap (#49) in position with cap screws (#48). Position slingers (#47) on the shaft.
6. Position the bracket (#35B) on the power frame (#57) and secure with cap screws (#5) and washers (#5A). Tighten screws evenly to assure proper alignment.
7. Position the Seal Plate (#35A) on the bracket (#35B) and secure with cap screws (#5B). Tighten screws evenly to assure proper alignment.
Installation of the Mechanical Seal-1650-1620 Pumps
8. Thoroughly clean the shaft sleeve and seal plate seal cavity. Replace the shaft sleeve (#25) or seal plate (#35A) if there is evidence of surface damage like pitting, corrosion, nicks or scratches.
9. Lubricate the shaft sleeve (#25) and seal plate (#35A) with soap and water or P-80™ rubber emulsion. Do not use petroleum lubricant.
Install a new insert gasket and a new seal (#27) insert down into the seal plate.
10. Slide a new rotating seal assembly (#27) on to the shaft sleeve. With a screwdriver, push the top of the compression ring until the seal is tight against the seal insert. Install seal spring.
Notice:
Refer to Table 2 "Seal Kit Selection Matrix" on Page 17 to determine the seal kit to be used for repair in relation to the power frame assembly for Pentair Fairbanks Nijhuis 1620- frame mounted pumps.
The mechanical seal (#27) is a precision product and must be treated as such. During installation, great care must be taken to avoid dropping any part of the seal. Take particular care not to scratch the lapped faces on the washer or the sealing seat.
11. Install O-ring (#10).
12. Install a new impeller key (#12).
13. Install impeller (#11), new impeller washer gasket (#9B), impeller washer (#9A), impeller seal (#9C) and cap screw (#9). Tighten cap screw per torque chart (see Table 4 on Page 18).
14. Install new casing gasket (#8). Then install the pump assembly into the volute.
15. Tighten volute cap screws (#5) per torque chart (see Table 4 on Page
18).
16. For Pentair Fairbanks Nijhuis 1620 pumps, install foot support cap screws (#62)
17. For Pentair Fairbanks Nijhuis 1620 pumps, install coupling and align.
(Follow coupling alignment procedure "Shaft/Coupling Alignment" on
Page 12).
18. Install drain plugs, close drain valve.
19. For Pentair Fairbanks Nijhuis 1620 pumps, reinstall the coupling guard.
20. Open isolation valves and inspect pump for leaks.
21. Return pump to service.
Do not start pump until all air and vapor has been bled and until making sure that there is liquid in the pump to provide the necessary lubrication for the packing.
Notice:
WHEN ORDERING SPARE PARTS ALWAYS INCLUDE THE
PUMP TYPE, SIZE, SERIAL NUMBER, AND THE PIECE NUMBER FROM
THE EXPLODED VIEW IN THIS MANUAL. ORDER ALL PARTS FROM
YOUR LOCAL AUTHORIZED DISTRIBUTOR OR PENTAIR FAIRBANKS
NIJHUIS CUSTOMER SERVICE.
PENTAIR FAIRBANKS NIJHUIS RESERVES THE RIGHT TO
SUBSTITUTE MATERIALS WITHOUT NOTICE.
20
FM-03-536 (11/20/19)
TROUBLESHOOTING GUIDE
THE FOLLOWING IS A LIST OF COMMON PROBLEMS AND THEIR PROBABLE CAUSES.
Symptoms Possible causes Possible remedies
Check and ensure correct voltage at motor terminals
Speed too low
Insufficient pressure or
Insufficient/no flow
Excessive power consumption
Abnormal noise and vibration
Wrong direction of rotation
Entrained air in pump
Air leaks into suction line
Leaking joints
Excessive leakage from seal
Insufficient submergence of suction pipe
Insufficient pressure at pump inlet
Clogged impeller
Damaged impeller
Worn wear rings
System head not as anticipated
Smaller impeller diameter
Speed too high
Rubbing or binding of rotating elements
Shaft bent
Worn wear rings
Head lower than rating, pumps too much liquid
Coupling misalignment
Foundation/grouting not rigid
Defective bearings
Rubbing or binding of rotating elements
Pump operating outside Allowable Operating
Region (AOR)
Entrained air in pump
Insufficient pressure at pump inlet
Check if rotating elements freely rotate
Check motor rotation with direction arrow on casing
Ensure correct motor wiring
Ensure all air is vented, and pump is adequately primed
Ensure eccentric reducer, if correctly installed
Tighten the suction piping flange bolts as required
Check for any external leakage and arrest
Inspect and replace mechanical seal, as required
Check and ensure sufficient pipe length, submerged well below the water surface
Ensure correct suction pipe sizing
Raise fluid level or move pump closer to the water level
Clean impeller as required
Check and replace impeller as required
Check and replace wear rings, if equipped
Contact manufacturer for correct pump sizing
Contact manufacturer for correct impeller sizing
Check and ensure correct voltage at motor terminals
Check if rotating elements are not rubbing against stationary components
Inspect shaft for any deformation and replace
Check and replace wear rings, if equipped
Contact manufacturer for correct pump/impeller sizing
Check and ensure alignment between pump and driver shaft
Ensure foundation is adequately sized and rigid to absorb the vibrations
Ensure foundation bolts are tightened to adequate torque
Check motor and/or pump for worn bearings, and replace as required
Check if rotating elements are not rubbing against stationary components
Ensure the pump is being operated within its Allowable
Operating region. Contact manufacturer for correct pump sizing.
Ensure all air is vented, and pump is adequately primed
Ensure eccentric reducer, if correctly installed
Ensure correct suction pipe sizing
Raise fluid level or move pump closer to the water level
FM-03-536 (11/20/19)
21
TROUBLESHOOTING GUIDE
Motor fails to start
Motor runs hot
Incorrect wiring
Wrong voltage
Switches not set
Tripped thermal overload relay
Blown fuses
Loose or broken wiring
Binding of rotating elements
Defective motor
Speed too high
Voltage lower than rated
Rubbing or binding of rotating elements
Check motor wiring against motor wiring diagram (on motor)
Check and ensure correct voltage at motor terminals
Set switches ON
Set relays ON
Replace fuses
Check and tighten connections. Replace broken wiring
Check if rotating elements freely rotate
Check and replace motor
Check and ensure correct voltage at motor terminals
Check and ensure correct voltage at motor terminals
Check if rotating elements are not rubbing against stationary components
Note: The pump delivered may not be fitted with all the components mentioned in the troubleshooting guide.
For further troubleshooting assistance, contact Pentair Fairbanks Nijhuis Customer Service or your nearest Pentair Fairbanks Nijhuis authorized distributor.
22
FM-03-536 (11/20/19)
ASSEMBLY EXPLODED VIEW
PENTAIR FAIRBANKS NIJHUIS®
MODEL 1650
CLOSE COUPLED CONFIGURATION
5A
5
5B
35B
5
35A
8
27
25
10 12
11
9B
4B
9A
9C
9
6
4A
Figure 45
Figure 45
Pentair Fairbanks Nijhuis Model 1650, close coupled configuration
FM-03-536 (11/20/19)
23
ASSEMBLY EXPLODED VIEW
PENTAIR FAIRBANKS NIJHUIS®
MODEL 1620
FRAME MOUNTED CONFIGURATION
48
5
35A
42 43
51A
49
52
53
8
27
25
10 12
11
9B
9A
9C
4B
9
55
34
54
57
43
51
5B
35B
6
4A
63A
62A 64
5A 5
47
Figure 46
Figure 46
Pentair Fairbanks Nijhuis Model 1620, frame mounted configuration
24
FM-03-536 (11/20/19)
PART LIST
54
55
57
62A.
48
49
52
53
35B.
42
43
47
32
33
34
35A.
62B.
63
64A/B.
25
27
11
12
9A.
9B.
9C.
10
ITEM NO.
4
4A/B.
5A.
8
9
5B.
6
PENTAIR FAIRBANKS NIJHUIS®
1650 AND 1620
Reference: Figure 45, 46 (Exploded Views)
Cap screw
Screw
Nameplate
Seal plate
Motor bracket
Key
Grease fitting
Slinger
Cap screw
Bearing cap
Retaining ring
Bearing
Bearing
Shaft
Power frame
Cap screw
Nut
Washer
Foot support
DESCRIPTION
Pipe plug
Cap screw
Cap screw washer
Cap screw
Casing
Gasket
Impeller screw
Impeller washer
Impeller gasket
Impeller seal
O-ring
Impeller
Impeller key
Sleeve
Mechanical seal
FM-03-536 (11/20/19)
25
PUMP - IMPELLER SIZE RELATION
6" 16x2A
1-1/2" 16x3
2" 16x4
2-1/2" 16x3
3" 16x4
4" 16x4
5" 16x4
6" 16x3
8" 16x2
4" 16x2
5" 16x2
6" 16x1
1-1/2" 16x2
2" 16x3
3" 16x3
4" 16x3A
5" 16x3
PUMP MODEL
1-1/4" 16x1
1-1/2" 16x1
2" 16x1
2-1/2" 16x1
3" 16x1
4" 16x1
5" 16x1
1-1/4" 16x2
1-1/2" 16x4
2" 16x2
2-1/2" 16x2
3" 16x2
MAX IMPELLER DIAMETER
7"
9.5"
11"
12"
13.5"
Note: Pump sizes are listed with an "x" as the 3rd digit, example 4" 16x4, here the "x" could be a 2 for Frame mounted pumps (4" 1624) or a 5 for Close coupled pumps (4" 1654).
26
FM-03-536 (11/20/19)
STANDARD LIMITED WARRANTY
WARRANTY
Seller warrants equipment (and its component parts) of its own manufacture against defects in materials and workmanship under normal use and service for one (1) year from the date of installation or start-up, or for eighteen (18) months after the date of shipment, whichever occurs first. Seller does not warrant accessories or components that are not manufactured by Seller; however, to the extent possible, Seller agrees to assign to Buyer its rights under the original manufacturer's warranty, without recourse to Seller. Buyer must give Seller notice in writing of any alleged defect covered by this warranty (together with all identifying details, including the serial number, the type of equipment, and the date of purchase) within thirty (30) days of the discovery of such defect during the warranty period. No claim made more than 30 days after the expiration of the warranty period shall be valid. Guarantees of performance and warranties are based on the use of original equipment manufactured (OEM) replacement parts. Seller assumes no responsibility or liability if alterations, non-authorized design modifications and/or non-OEM replacement parts are incorporated If requested by Seller, any equipment (or its component parts) must be promptly returned to Seller prior to any attempted repair, or sent to an authorized service station designated by Seller, and Buyer shall prepay all shipping expenses. Seller shall not be liable for any loss or damage to goods in transit, nor will any warranty claim be valid unless the returned goods are received intact and undamaged as a result of shipment. Repaired or replaced material returned to customer will be shipped F.O.B., Seller's factory. Seller will not give Buyer credit for parts or equipment returned to Seller, and will not accept delivery of any such parts or equipment, unless Buyer has obtained Seller's approval in writing. The warranty extends to repaired or replaced parts of Seller's manufacture for ninety (90) days or for the remainder of the original warranty period applicable to the equipment or parts being repaired or replaced, whichever is greater. This warranty applies to the repaired or replaced part and is not extended to the product or any other component of the product being repaired. Repair parts of its own manufacture sold after the original warranty period are warranted for a period of one (1) year from shipment against defects in materials and workmanship under normal use and service. This warranty applies to the replacement part only and is not extended to the product or any other component of the product being repaired. Seller may substitute new equipment or improve part(s) of any equipment judged defective without further liability. All repairs or services performed by Seller, which are not covered by this warranty, will be charged in accordance with Seller's standard prices then in effect.
THIS WARRANTY IS THE SOLE WARRANTY OF SELLER AND SELLER HEREBY EXPRESSLY DISCLAIMS AND BUYER WAIVES ALL OTHER WARRANTIES
EXPRESSED, IMPLIED IN LAW OR IMPLIED IN FACT, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Seller's sole obligation under this warranty shall be, at its option, to repair or replace any equipment (or its component parts) which has a defect covered by this warranty, or to refund the purchase price of such equipment or part. Under the terms of this warranty, Seller shall not be liable for (a) consequential, collateral, special or liquidated losses or damages; (b) equipment conditions caused by normal wear and tear, abnormal conditions of use, accident, neglect, or misuse of said equipment; (c) the expense of, and loss or damage caused by, repairs or alterations made by anyone other than the Seller; (d) damage caused by abrasive materials, chemicals, scale deposits, corrosion, lightning, improper voltage, mishandling, or other similar conditions; (e) any loss, damage, or expense relating to or resulting from installation, removal or reinstallation of equipment; (f) any labor costs or charges incurred in repairing or replacing defective equipment or parts, including the cost of reinstalling parts that are repaired or replaced by
Seller; (g) any expense of shipment of equipment or repaired or replacement parts; or (h) any other loss, damage or expense of any nature.
The above warranty shall not apply to any equipment which may be separately covered by any alternate or special warranties.
PERFORMANCE: In the absence of Certified Pump Performance Tests, equipment performance is not warranted or guaranteed. Performance curves and other information submitted to Buyer are approximate and no warranty or guarantee shall be deemed to arise as a result of such submittal. All testing shall be done in accordance with Seller's standard policy under Hydraulic Institute procedures.
LIABILITY LIMITATIONS: Under no circumstances shall the Seller have any liability under the Order or otherwise for liquidated damages or for collateral, consequential or special damages or for loss of profits, or for actual losses or for loss of production or progress of construction, regardless of the cause of such damages or losses. In any event, Seller's aggregate total liability under the Order or otherwise shall not exceed the contract price.
ACTS OF GOD: Seller shall in no event be liable for delays in delivery of the equipment or other failures to perform caused by fires, acts of God, strikes, labor difficulties, acts of governmental or military authorities, delays in transportation or procuring materials, or causes of any kind beyond Seller's control.
COMPLIANCE WITH LAW: Seller agrees to comply with all United States laws and regulations applicable to the manufacturing of the subject equipment. Such compliance shall include: The Fair Labor Standards Acts of 1938, as amended; Equal Employment Opportunity clauses of Executive
Order 11246, as amended; Occupational Safety and Health Act of 1970 and the standards promulgated thereunder, if applicable. Since compliance with the various Federal, State, and Local laws and regulations concerning occupational health and safety, pollution or local codes are affected by the use, installation and operation of the equipment and other matters over which Seller has no control, Seller assumes no responsibility for compliance with those laws and regulations, whether by way of indemnity, warranty, or otherwise. It is incumbent upon the Buyer to specify equipment which complies with local codes and ordinances.
FM-03-536 (11/20/19)
27
800 Airport Road | North Aurora, Illinois 60542 | Ph: 630.859.7000 | pentair.com
For a detailed list of where Pentair trademarks are registered, please visit www.pentair.com/en/registrations.html. Pentair trademarks and logos are owned by Pentair PLC. or its affiliates.
Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.
FM-03-536 (11/20/19) ©2019 Pentair. All Rights Reserved.