Trion Air Boss® ES Cell-G Electrostatic Replacement Cell is an advanced air purification solution designed to enhance indoor air quality and provide a healthier environment. With its powerful electrostatic technology, the Cell-G effectively removes airborne contaminants, including dust, pollen, dander, smoke, and odor, leaving your air cleaner and fresher.
The Cell-G is engineered to be versatile and can be used independently or integrated into existing air handling systems. Its easy installation process allows for quick and seamless integration, making it suitable for various applications, including residential, commercial, and industrial spaces.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
AIR BOSS
®
ES CELL-G
Electrostatic Replacement Cell
Installation & Operation Manual
Contact Information
Headquarters
Inc.
101 McNeill Rd. The Cavendish Center Boscstr. 60
Tel. 800 884 0002
Fax 800 458 2379 www.trioninc.com [email protected]
Fedders International
No. 728 Fuzhou Rd.
Winchester, Hampshire
SO23 OLB, UK
Tel. 44 0 1962 840465
Fax 44 0 1962 828619
Germany
Tel. 49 0 2237 922 103
Fax 49 0 2237 922 104
Fedders International Fedders International
A-30, Chintels House 128 Joo Seng Road
Raffles City Office Tower
Shanghai, P.R. China, 200001
Tel. 86 21 6340 3232
Fax. 86 21 6340 3867
New Delhi, India 110048
Tel. 91 11 5173 0730
Fax 91 11 5173 0743
Manual Part Number 157331-001· May 2004
DP Computer Building
Singapore 368 356
Tel. 65 6286 0995
65
SPECIFICATIONS: CELL-G
Power Consumption:
Ionizer Voltage Range:
Collector Voltage Range:
Maximum Airflow Temp:
(Through Cells)
Maximum Cell Washing
Temperature:
75W max
@ 120 VAC
10-12 KVDC
5-6 KVDC
140 F (60 C)
160 F (71 C)
Dimensions: 20.69” L x 14.13” W x 18.43” H
(525.5 x 358.8 x 468.1 mm)
INSTALLATION
1. UNPACK AND INSPECT
Upon receipt, all shipping containers and their contents should be examined for damage. Any damage occurring in shipment must be immediately reported to the carrier, an inspection report completed and a claim filed with the carrier at the receiving point.
The Cell-G filter is shipped assembled.
Please check to ensure all additional components are included:
2 acorn nuts
2 spring contacts
2 flat washers
2. INSTALLING THE Cell-G FILTER
The Cell-G can be used in conjunction with or independent of the competitor’s collection cells inside their cabinet. Simply slide the cell into the cabinet making sure the insulated springs make contact with the power source or an adjacent cell.
MAINTENANCE
WARNING !
Sharp Edges Can Cause
Personal Injury
Wear protective gloves to prevent cuts from sharp edges.
WARNING!
Electric Shock Hazard
Can Cause Personal Injury or
Death
The following procedures will expose hazardous electrically charged parts. Disconnect power before proceeding.
CLEANING FILTER
The IONIZER/COLLECTOR CELL(S) should be removed from the unit periodically and soaked in a solution of hot water and a commercial detergent for 2 to 4 hours. Your Trion
Distributor carries a detergent, called Tri-dex, specially formulated for cleaning collector cells. The frequency of cleaning is dependent on the contaminant being collected. Liquid aerosol is virtually self cleaning while welding smoke may require accumulation being blown or rapped off every few days.
Collector cells should be kept clean for maximum efficiency.
Wash Dirt Collecting Elements
1. Turn the control switch OFF and disconnect power to the unit.
2. Open the cell access door.
2
3. Remove ionizer/collector cells and wash in hot detergent water. If the collected contaminant is of an extremely dry nature it can be blown from the collecting cells with a pressure hose or removed by gently tapping the end plate of the cell. When blowing or tapping cell clean, carry cell outdoors.
4. Remove the mechanical pre-filter. Remove collected dust or lint by vacuuming or brushing. Wash with warm, soapy water.
5. Rinse all components thoroughly in warm, clear water and permit them to DRIP DRY
THOROUGHLY.
6. Replace pre-filter and ionizer/collector cells. BE SURE AIR FLOW ARROW
POINTS TOWARDS BLOWER.
7. Close access door, reconnect power to the unit.
8. Turn control switch to “ON”. If arcing occurs or the indicating light flickers, the components may still be damp. Simply shut off and allow more time to dry.
CAUTION !
Do not run objects, such as a bottle brush, between the plates of the cell. This might change the plate spacing or damage the ionizer plates.
REPLACEMENT PARTS ORDERING
INFORMATION
The following page contains exploded views and Replacement Parts for the Trion Cell-G.
Use it to determine the part numbers of items which are needed.
Contact Trion for replacement parts.
3
LIMITED WARRANTY
Trion warrants this equipment to be free from defects in workmanship and material for a period of 1 year after shipment. This warranty is limited, however, to the repair or replacement of defective equipment, which is returned, freight prepaid, to manufacturer’s factory.
This limited warranty does not apply to any part or component that is damaged in transit or when handling, has been subject to misuse, negligence or accident, has not been installed, operated or serviced according to these instructions, has been operated beyond the factory rated capacity or has been altered in any way.
Trion’s liability is limited to replacement of defective parts or components and does not include any cost of labor (including, but not limited to, labor required to remove and/or reinstall any defective part) other than Trion factory labor.
Trion shall not be responsible for loss of use of any product, loss of time, inconvenience, or damage to other equipment or any other indirect or consequential damage, with respect to property, whether as a result of breach of warranty, neglect or otherwise.
THE WARRANTY AND LIABILITIES SET
FORTH ABOVE ARE IN LIEU OF ALL
OTHER WARRANTIES AND LIABILITIES,
EXPRESSED OR IMPLIED, IN LAW OR IN
FACT, INCLUDING ANY IMPLIED WARRAN-
TIES OF MERCHANTABILITY AND FITNESS
FOR PARTICULAR PURPOSE.
The foregoing shall constitute the total liability of Trion in the case of defective performance of all or any of the equipment or services provided to Buyer. Buyer agrees to accept and hereby accepts the foregoing as the sole and exclusive remedy for any breach or alleged breach of warranty by Trion
.