A
FLUSH END CAP INSTALLATION INSTRUCTIONS
4500 SERIES EXIT DEVICE
4600 SERIES EXIT DEVICE
4500/4600 SERIES FLUSH END CAP
Installation Instructions
I-ED01887
WARNING: FOR PROPER FIT DEVICE CUT MUST BE SQUARE AND EDGE DEBURRED.
Instructions: To replace an existing end cap with a flush end cap.
Step 1: Remove existing end cap by removing the cover screws.
Step 2: Remove the existing end cap bracket by removing end cap bracket screws.
Step 3: Using the existing device mounting holes install the new flush end cap bracket using the (2)
mounting screws.
Step 4: Install the flush end cap using the (2) end cap screws.
Step 5: If the flush end cap is not flush with the exit device, remove flush end cap and adjust the mounting
screws and the flush end cap bracket as needed.
(1) Flush End Cap Bracket
(2) Mounting Screws (1) Flush End Cap
(2) End Cap Screws
Step 5
REV: - REV DATE: 11/24/15 Page 1 of 1
DETAIL C
C
advertisement