DKS 9000 Quick start guide

DKS  9000 Quick start guide
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD “FULL OPEN”
7
dio
Re
cei
Chain Adjustment
6
9
8
*
ver
0
Loc
ain
kP
#
late
Bra
cke
t
SW
ng
eni
Op ction
e
Dir
1
8
DIP-Switches
CO
it
m
Li
e
ar
Sp
it
m
Li
C
VA
24
or
ot
M
N
t
eu
l
ra
3
D
or
ot
M
2
1
M
7
6
5
4
r
Idleeel
h
W
A
B
D
ON
itc
Sw N
O
in ition.
pos
E
AT
ly
ER
on
OP use
TO
an
SH
nici
PU tech
Ma
t
Cenition
s
o
P
Reset
nu
al
Re
SW 2
1. Opening Direction (See Illustration)
2. OFF
3. ON
Auto-Close Timer
4. ON
TIME
5. OFF
DELAY
6. OFF
E
7. OFF
8. OFF
1. OFF
2. OFF
3. ON
4. OFF
se
1 23
Adjust
1 to 23 sec.
(See reverse side for
more information).
1
ng
eni n
Op ectio
Dir
it
du
n
co
ch
in s.
4- p
3/ ee
se sw
U ith
w
p
Loonduit
o
C
Co
n
MU crete
ST pa
be d
lev
el!
r
we
Po it
C
A ndu
Co
Two 115 VAC
Convenience Outlets
For access control and safety device AC power.
um
im und.
l
n
S
i
m ro
2”
4”ove g
”x
8
/
.
3 d)
is ng
ab
4)
e ( plie
pad uildi
Us t sup
e
t
re al b
(No
onc d loc ded).
c
the an en
of tions omm
h
t
i
c
dep cond te re
d
l
e
n
i
r
u
o
c
gro by s con
ow ined rced
l
e
B rm nfo
i
e
det es (re
Warning Signs
d
co
eev
Co
nc
ret
Pae
d
rs
cho
n
eA
4” minimum
space
between the
gate and
operator
chassis.
Permanently mount signs on BOTH sides of the
gate area and make sure they are easily visible.
Copyright 2020 DoorKing®, Inc. All rights reserved.
4”
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
Tip: It is recommended that a surge suppressor be
installed on the input high voltage power line.
A
Chassis
Ground
115 VAC
Note: “Optional” High
Voltage Kit black and
white wires connect
the same as shown.
See High Voltage Kit
instruction sheet for
more information.
Input Power Line:
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
Loop Detectors
B Not included - Refer to the Installation/Owner’s manual
for more information about DoorKing’s Plug-In loop
detectors. DoorKing highly recommends that loops and
loop detectors are installed with this slide gate operator.
DoorKing offers a free “Loop and Loop-Detectors
Information Manual” PDF located at DoorKing’s web
site for more information. www.doorking.com
24”
m
tto
Bo ition
s
Po
High Voltage Connection
HIGH VOLTAGE
Chain, Conduit Area and Concrete
lea
Operator Chassis
3.5”
Gate
1 2 3 4 5 6 7 8
eel
Whition
r
e
Idl Pos
Top
er
h1
r
1 2 3 4
we
Po
operator until the “DIP-Switches”
and the “Limit Switches” have
been adjusted. Damage could
occur to the gate and operator.
SW 1
ON
DO NOT power up and cycle the
ON
E
B
U.S.A.
DANGER
Typical Single Operator Settings
1 2 3 4 5 6 7 8
Chain brackets MUST be
mounted so the chain
remains the same height
as it is on the idler wheels!
SW
Pedestrians must be supplied with
a separate access opening.
For complete safety, installation
and adjustment of operator
instructions, please refer to the
Series 9000 Installation/Owner’s
manual.
C
Adjust the chain nuts to tighten the chain. The chain
should sag no more than one (1) inch per 10 feet of
chain travel. Do not over tighten the chain.
120 S. Glasgow Avenue
Inglewood, California 90301
Hot
4
5
e
ir
W
3-
Ra
3
2
1
Ch
1 2 3 4 5 6 7 8
Adjust the 2 limit nuts by depressing the lock plate and spin nuts to
desired open and closed gate positions. After adjusting, make sure
the lock-plate is engaged in the slots on the limit-nuts to prevent
them from rotating. See manual for more information.
UL 325 August
2018 Standard
Model 9000 is intended for
installation only on sliding
gates used for vehicles.
Neutral
ON
Adjustment of Limit Switches
1
itch
Sw FF
in Oition.
s
po
13.5”
Center
of
concrete
pad
4.5” Conduit Area
24”
Radio Receiver
C Not included - Refer to a specific Radio Receiver
Manual (available from www.doorking.com) for more
information on radio receivers and antenna installation.
(See reverse side for wiring)
Concrete Pad
Operator and chain
MUST be parallel to gate!
Chain bracket MUST line
up with chain idler wheels!
Entrapment Protection must be provided for the gate
system where the risk of entrapment or obstruction exists.
The operator will NOT run without one or more monitored
type B1 or B2 external entrapment protection devices in
EACH direction of gate travel (minimum of 2 external
devices required). See manual for more information.
9000-066-N-9-20
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - DIP-SWITCH AND WIRING REFERENCE
Important: Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where
the user is prevented from reaching over, under, around or through the gate to operate the controls. Emergency access controls only
accessible by authorized personnel (e.g., fire, police, EMS) may be placed at any location in the line-of-sight of the gate.
N.O.
Lock Disengaged
To #3 Stop N.C.
To #4 Com
24 Volt
8
Com
Relay
7
6
5
4
3
2
3-Pin
Remote
Terminal
1
2
3
1
Com
Mo
tor
N.C.
Mo
tor
Neu
tral
Changes direction operator will cycle open
upon initial AC power up and open command.
#4 Com
24V
AC
Place jumper
on bottom
2 pins when
using 4-pin
terminal.
Operator Stopped
it
Opening direction
using OFF setting.
OP
ST
Lim
Opening direction
using ON setting.
#3 Stop N.C.
N.O.
Lock Engaged
re
Description
SE
CLO
Spa
#2 Close N.O.
EN
OP
3-Wire Radio
Receiver
Com
it
1
Primary
Operator
Opening
Direction
Setting
#1 Open N.O.
N.C.
Note: When
using 3-button
control station
AND interlock
switch together,
#3 terminal
(N.C.) must be
wired in series.
Lim
SW 1 DIP-Switches
3-Pin With
Jumper
U.S.A.
Normally Closed
Interlock Switch
Operator Cycling
Use a standard 4-wire 3-button control station. DoorKing’s
3-wire 3-button control station cannot be used.
M
3-Button Control Station
For safety and installation instructions, please refer to the Installation/Owner’s manual.
Function
120 S. Glasgow Avenue
Inglewood, California 90301
4-Pin Non-Removable Terminal
Pedestrians must be supplied with a separate access opening.
CO
Model 9000 is intended for installation only on slide gates used for vehicles.
Switch
UL 325 August
2018 Standard
Power is limited
to 250 mamps.
wer
Po
Relay
7-OFF
7-OFF
7-ON
7-ON
8-OFF
8-ON
8-OFF
8-ON
1
SW1 ON
UL 325
DIP switches
TIME
DELAY
REV SENSE
PRIMARY
1477-010
UL 325
Terminal
1
2
3
4
5
6
1
Quick-Close
Timer Override
2
3
4
Magnetic lock
OE
CE
G
8
24
VDC
NC NO
Com
OFF Normal Setting. Timer will function normally.
ON Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
OFF Normal Setting. Magnetic lock is not used.
ON Magnetic lock is used and connected to terminals 9 and 12.
20
4405-018
SH
hn
tec
PU
Supplied
Wire Harness
Type of wiring to be used on ALL
external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better
electrical, mechanical, and flammability
ratings.
1
2
3
4
5
6
7
8
9
10
11
12
G
Description
ON Normal Setting. Switch 3 MUST be turned ON for Model 9000 operator.
OFF Normal Setting. Switch 4 MUST be turned OFF for Model 9000 operator.
6
CB
SW 2 DIP-Switches
Setting
5
OB 7
Note: After a DIP-switch setting is changed, power
must be turned
REVERSE
LOOPto take affect.
OFF and then turned back on for the new setting
Function
24
VAC
4
4
1 2 3 4
REV SENSE
SECONDARY
Switch
Full
Open
3
POWER
Normal Setting. Relay activates when gate is at open limit.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.
2
2
OFF Normal Setting. Switch must be OFF for single operator.
ON Switch must be ON when primary/secondary (dual) gates are used.
Single Operator
Dual Operators
Com
Activation Note: Activation of this device will OPEN gate regardless of the status of the
open direction monitored external entrapment protection device(s). If gate is opening,
and the operator’s inherent entrapment protection system detects an obstruction, the
operator will reverse approx. 2 inches and go into a hard shutdown. Operator reset
button MUST be pushed to function again OR cycle operator’s power.
13
14
15
16
17
18
19
20
Terminal #3 Note: Exceeding 250 mA of power from this terminal may cause the circuit board transformer to overheat,
causing intermittent problems.
IMPORTANT: Only 1 monitored Device can be connected
to each input. An OPTIONAL Expansion Kit (sold
separately) will allow connection for additional devices.
Wall
Open Beam
Filler Post If necessary
Open Beam necessary when area between
gate and wall is between 2 1/4” and 16”.
UL 325 DIP-Switches
ON
DIP-switches MUST be turned ON
for each device wired to terminal.
#2 Normally Open
External Entrapment
Protection Devices
Close Beam
Telephone
Entry
Open Edge
Closed Gate
Close Edge
7 and 8
FIRE
1 2 3 4
Stops Gate
FIRE
ON SW2
5
Dual Gate Operators Note: Connect device to BOTH operators, both gates will fully open.
SW1
OFF The output wired to terminal #4 becomes the output from the exit loop detector
plugged into the EXIT Loop port.
P2
ON Normal Setting. Terminal #4 is a normal full open input.
OFF Auto-close timer is OFF. Manual input required to close gate.
ON Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.
EXIT
LOOP
reverse gate during
OFF Normal Setting. Input to terminal #6 and reverse loop will
close cycle.
ON Input to terminal #6 and/or reverse loop will stop gate during close cycle – gate will
continue to close after input to terminal #6 and/or reverse loop are cleared (Helps
prevent tailgating).
Reverses Gate
6
Changes direction operator will cycle open
upon initial AC power up and open command.
1 2 3 4 5 6 7 8
4
Auto-Close
Timer
Opening direction
using OFF setting.
ON
3
Exit Loop Port
Output
Full Open Input
Opening direction
using ON setting.
Gate will ONLY OPEN when this device is activated by authorized personnel ONLY (fire,
police, EMS) and operator has power. Alarm will sound during entire open cycle.
Operator will then go into a hard shutdown once fully opened. Operator MUST be reset to
function normally again. This device MUST be mounted in the line-of-site of gate so
authorized personnel can monitor gate movement.
Open Edge
2
Secondary
Operator
Opening
Direction
TO
icia OP
n ER
use AT
E
on
ly
Fire Dept Open
UL 325 Terminal
1 2 3 4
OPEN Beam
UL 325 switch 1
CLOSE Beam
UL 325 switch 2
OPEN Edge
UL 325 switch 3
CLOSE Edge
UL 325 switch 4
(Common) Ground
(Common) Ground
#9 Normally
Close
24 Volt 1 amp max.
1
2
3
4
5
6
Magnetic Lock
Power (24-Volt DC) and
logic output. Power is shut
off .5 sec. prior to gate
starting and remains off
while gate is opening and
in the open position.
Stand-Alone
Key Switch
Connect ONLY MONITORED
Devices
IMPORTANT: Monitored Photo and
Edge sensors must be end-of-line
resistive types. See specific
manufacturer's wiring manual for
more information.
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists.
The operator will NOT run without one or more monitored type B1 or B2 external entrapment protection devices
in EACH direction of gate travel (minimum of 2 external devices required).
Stand-Alone
Keypad
Stand-Alone
Card Reader
Note: All stand-alone
and telephone entry devices must
use a separate power source.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement