DKS 9000 Quick start guide

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD “FULL OPEN” 7 dio Re cei Chain Adjustment 6 9 8 * ver 0 Loc ain kP # late Bra cke t SW ng eni Op ction e Dir 1 8 DIP-Switches CO it m Li e ar Sp it m Li C VA 24 or ot M N t eu l ra 3 D or ot M 2 1 M 7 6 5 4 r Idleeel h W A B D ON itc Sw N O in ition. pos E AT ly ER on OP use TO an SH nici PU tech Ma t Cenition s o P Reset nu al Re SW 2 1. Opening Direction (See Illustration) 2. OFF 3. ON Auto-Close Timer 4. ON TIME 5. OFF DELAY 6. OFF E 7. OFF 8. OFF 1. OFF 2. OFF 3. ON 4. OFF se 1 23 Adjust 1 to 23 sec. (See reverse side for more information). 1 ng eni n Op ectio Dir it du n co ch in s. 4- p 3/ ee se sw U ith w p Loonduit o C Co n MU crete ST pa be d lev el! r we Po it C A ndu Co Two 115 VAC Convenience Outlets For access control and safety device AC power. um im und. l n S i m ro 2” 4”ove g ”x 8 / . 3 d) is ng ab 4) e ( plie pad uildi Us t sup e t re al b (No onc d loc ded). c the an en of tions omm h t i c dep cond te re d l e n i r u o c gro by s con ow ined rced l e B rm nfo i e det es (re Warning Signs d co eev Co nc ret Pae d rs cho n eA 4” minimum space between the gate and operator chassis. Permanently mount signs on BOTH sides of the gate area and make sure they are easily visible. Copyright 2020 DoorKing®, Inc. All rights reserved. 4” GATE OPERATOR MUST BE PROPERLY GROUNDED!! Tip: It is recommended that a surge suppressor be installed on the input high voltage power line. A Chassis Ground 115 VAC Note: “Optional” High Voltage Kit black and white wires connect the same as shown. See High Voltage Kit instruction sheet for more information. Input Power Line: White - Neutral Black - 115 VAC Hot Green - Chassis Ground Loop Detectors B Not included - Refer to the Installation/Owner’s manual for more information about DoorKing’s Plug-In loop detectors. DoorKing highly recommends that loops and loop detectors are installed with this slide gate operator. DoorKing offers a free “Loop and Loop-Detectors Information Manual” PDF located at DoorKing’s web site for more information. www.doorking.com 24” m tto Bo ition s Po High Voltage Connection HIGH VOLTAGE Chain, Conduit Area and Concrete lea Operator Chassis 3.5” Gate 1 2 3 4 5 6 7 8 eel Whition r e Idl Pos Top er h1 r 1 2 3 4 we Po operator until the “DIP-Switches” and the “Limit Switches” have been adjusted. Damage could occur to the gate and operator. SW 1 ON DO NOT power up and cycle the ON E B U.S.A. DANGER Typical Single Operator Settings 1 2 3 4 5 6 7 8 Chain brackets MUST be mounted so the chain remains the same height as it is on the idler wheels! SW Pedestrians must be supplied with a separate access opening. For complete safety, installation and adjustment of operator instructions, please refer to the Series 9000 Installation/Owner’s manual. C Adjust the chain nuts to tighten the chain. The chain should sag no more than one (1) inch per 10 feet of chain travel. Do not over tighten the chain. 120 S. Glasgow Avenue Inglewood, California 90301 Hot 4 5 e ir W 3- Ra 3 2 1 Ch 1 2 3 4 5 6 7 8 Adjust the 2 limit nuts by depressing the lock plate and spin nuts to desired open and closed gate positions. After adjusting, make sure the lock-plate is engaged in the slots on the limit-nuts to prevent them from rotating. See manual for more information. UL 325 August 2018 Standard Model 9000 is intended for installation only on sliding gates used for vehicles. Neutral ON Adjustment of Limit Switches 1 itch Sw FF in Oition. s po 13.5” Center of concrete pad 4.5” Conduit Area 24” Radio Receiver C Not included - Refer to a specific Radio Receiver Manual (available from www.doorking.com) for more information on radio receivers and antenna installation. (See reverse side for wiring) Concrete Pad Operator and chain MUST be parallel to gate! Chain bracket MUST line up with chain idler wheels! Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will NOT run without one or more monitored type B1 or B2 external entrapment protection devices in EACH direction of gate travel (minimum of 2 external devices required). See manual for more information. 9000-066-N-9-20 QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - DIP-SWITCH AND WIRING REFERENCE Important: Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be placed at any location in the line-of-sight of the gate. N.O. Lock Disengaged To #3 Stop N.C. To #4 Com 24 Volt 8 Com Relay 7 6 5 4 3 2 3-Pin Remote Terminal 1 2 3 1 Com Mo tor N.C. Mo tor Neu tral Changes direction operator will cycle open upon initial AC power up and open command. #4 Com 24V AC Place jumper on bottom 2 pins when using 4-pin terminal. Operator Stopped it Opening direction using OFF setting. OP ST Lim Opening direction using ON setting. #3 Stop N.C. N.O. Lock Engaged re Description SE CLO Spa #2 Close N.O. EN OP 3-Wire Radio Receiver Com it 1 Primary Operator Opening Direction Setting #1 Open N.O. N.C. Note: When using 3-button control station AND interlock switch together, #3 terminal (N.C.) must be wired in series. Lim SW 1 DIP-Switches 3-Pin With Jumper U.S.A. Normally Closed Interlock Switch Operator Cycling Use a standard 4-wire 3-button control station. DoorKing’s 3-wire 3-button control station cannot be used. M 3-Button Control Station For safety and installation instructions, please refer to the Installation/Owner’s manual. Function 120 S. Glasgow Avenue Inglewood, California 90301 4-Pin Non-Removable Terminal Pedestrians must be supplied with a separate access opening. CO Model 9000 is intended for installation only on slide gates used for vehicles. Switch UL 325 August 2018 Standard Power is limited to 250 mamps. wer Po Relay 7-OFF 7-OFF 7-ON 7-ON 8-OFF 8-ON 8-OFF 8-ON 1 SW1 ON UL 325 DIP switches TIME DELAY REV SENSE PRIMARY 1477-010 UL 325 Terminal 1 2 3 4 5 6 1 Quick-Close Timer Override 2 3 4 Magnetic lock OE CE G 8 24 VDC NC NO Com OFF Normal Setting. Timer will function normally. ON Opening gate will stop and begin to close as soon as all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the distance the gate has opened. OFF Normal Setting. Magnetic lock is not used. ON Magnetic lock is used and connected to terminals 9 and 12. 20 4405-018 SH hn tec PU Supplied Wire Harness Type of wiring to be used on ALL external devices: A) Type CL2, CL2P, CL2R, or CL2X. B) Other cable with equivalent or better electrical, mechanical, and flammability ratings. 1 2 3 4 5 6 7 8 9 10 11 12 G Description ON Normal Setting. Switch 3 MUST be turned ON for Model 9000 operator. OFF Normal Setting. Switch 4 MUST be turned OFF for Model 9000 operator. 6 CB SW 2 DIP-Switches Setting 5 OB 7 Note: After a DIP-switch setting is changed, power must be turned REVERSE LOOPto take affect. OFF and then turned back on for the new setting Function 24 VAC 4 4 1 2 3 4 REV SENSE SECONDARY Switch Full Open 3 POWER Normal Setting. Relay activates when gate is at open limit. Relay activates when gate is not closed. Relay activates when gate is opening and open. Relay activates during opening and closing cycle. 2 2 OFF Normal Setting. Switch must be OFF for single operator. ON Switch must be ON when primary/secondary (dual) gates are used. Single Operator Dual Operators Com Activation Note: Activation of this device will OPEN gate regardless of the status of the open direction monitored external entrapment protection device(s). If gate is opening, and the operator’s inherent entrapment protection system detects an obstruction, the operator will reverse approx. 2 inches and go into a hard shutdown. Operator reset button MUST be pushed to function again OR cycle operator’s power. 13 14 15 16 17 18 19 20 Terminal #3 Note: Exceeding 250 mA of power from this terminal may cause the circuit board transformer to overheat, causing intermittent problems. IMPORTANT: Only 1 monitored Device can be connected to each input. An OPTIONAL Expansion Kit (sold separately) will allow connection for additional devices. Wall Open Beam Filler Post If necessary Open Beam necessary when area between gate and wall is between 2 1/4” and 16”. UL 325 DIP-Switches ON DIP-switches MUST be turned ON for each device wired to terminal. #2 Normally Open External Entrapment Protection Devices Close Beam Telephone Entry Open Edge Closed Gate Close Edge 7 and 8 FIRE 1 2 3 4 Stops Gate FIRE ON SW2 5 Dual Gate Operators Note: Connect device to BOTH operators, both gates will fully open. SW1 OFF The output wired to terminal #4 becomes the output from the exit loop detector plugged into the EXIT Loop port. P2 ON Normal Setting. Terminal #4 is a normal full open input. OFF Auto-close timer is OFF. Manual input required to close gate. ON Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds. EXIT LOOP reverse gate during OFF Normal Setting. Input to terminal #6 and reverse loop will close cycle. ON Input to terminal #6 and/or reverse loop will stop gate during close cycle – gate will continue to close after input to terminal #6 and/or reverse loop are cleared (Helps prevent tailgating). Reverses Gate 6 Changes direction operator will cycle open upon initial AC power up and open command. 1 2 3 4 5 6 7 8 4 Auto-Close Timer Opening direction using OFF setting. ON 3 Exit Loop Port Output Full Open Input Opening direction using ON setting. Gate will ONLY OPEN when this device is activated by authorized personnel ONLY (fire, police, EMS) and operator has power. Alarm will sound during entire open cycle. Operator will then go into a hard shutdown once fully opened. Operator MUST be reset to function normally again. This device MUST be mounted in the line-of-site of gate so authorized personnel can monitor gate movement. Open Edge 2 Secondary Operator Opening Direction TO icia OP n ER use AT E on ly Fire Dept Open UL 325 Terminal 1 2 3 4 OPEN Beam UL 325 switch 1 CLOSE Beam UL 325 switch 2 OPEN Edge UL 325 switch 3 CLOSE Edge UL 325 switch 4 (Common) Ground (Common) Ground #9 Normally Close 24 Volt 1 amp max. 1 2 3 4 5 6 Magnetic Lock Power (24-Volt DC) and logic output. Power is shut off .5 sec. prior to gate starting and remains off while gate is opening and in the open position. Stand-Alone Key Switch Connect ONLY MONITORED Devices IMPORTANT: Monitored Photo and Edge sensors must be end-of-line resistive types. See specific manufacturer's wiring manual for more information. Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will NOT run without one or more monitored type B1 or B2 external entrapment protection devices in EACH direction of gate travel (minimum of 2 external devices required). Stand-Alone Keypad Stand-Alone Card Reader Note: All stand-alone and telephone entry devices must use a separate power source.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement