MAXIMUS MHX

EX-PROOF HOUSING

MHX+MHXWBS

DESCRIPTION

These explosion-proof housings for the MAXIMUS range have been certified and designed to meet the strictest standards regarding installation in potentially explosive environments, i.e. where there is the presence of gas and flammable dusts.

The MAXIMUS range ensures excellent performance for monitoring critical processes in areas that carry a risk of explosion, such as refineries, gas pipelines, oil tankers, offshore platforms, industrial processes, chemical industries, etc.

Equipped with heating, the housing has the same installation and operating temperatures, of between -40° C and + 60° (-40°F / +140°F).

In the version with wiper, MHX is equipped with an integrated telemetry receiver that allows, through the RS485 serial interface, to receive data from the remote control for the activation of the wiper / washer and for switching an eventual external illuminator.

The wiring is made easier thanks to the removable connectors on the circuit board.

The control board, with removable connectors, is also equipped with an input for the wiper activation through a dry contact.

The housing can eventually be controlled by VMS through a video encoder with RS485 serial port.

CERTIFICATIONS

MAIN FEATURES

Certifications Ex d for use in Zone 1 and 2, Group IIC (Gas), and in Zone Ex tb 21 and 22 (Dust)

Made of AISI 316L electropolished stainless steel

2 threaded holes ¾” NPT for use of cable glands or conduit

Integrated telemetry receiver for version with wiper

Sunshield and heater included

Power supply: 230Vac, 24Vac or 120Vac

Ambient temperature: from -40°C (-40°F) up to +60°C (140°F)

Internal usable area (WxHxL): 80x82x245mm (3.1x3.2x9.6in)

Options:

• Wiper

WWW.VIDEOTEC.COM - DATA SHEETS

MAXIMUS-MHX_EN_2020-03-12

Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.

TECHNICAL DATA

GENERAL

AISI 316L stainless steel construction

Passivated and electropolished external surfaces

Silicone O-ring seals

MECHANICAL

2 holes 3/4" NPT for cable entry

Sunshield

Unit weight: 16.5kg (36lb)

HOUSING'S WINDOW

Tempered window glass

• Usable diameter: 75mm (3.0in)

• Thick: 12mm (0.47in)

ELECTRICAL

Supply voltage/Current consumption:

• 230Vac, 0.34A, 50/60Hz

• 120Vac, 0.5A, 50/60Hz

• 24Vac, 2.2A, 50/60Hz

Heater (Ton 15°C±4°C (59°F±7°F), Toff 22°C±3°C (72°F±5°F))

COMMUNICATIONS

Serial interface: 1 RS-485 line, half-duplex

Addressable units: Up to 31, via dip-switch

Protocols:

• PELCO D: 2400baud, 9600baud

• VIDEOTEC MACRO: 9600baud, 38400baud

PELCO is registered trademark.

The product may be interfaced with devices not manufactured by VIDEOTEC. It is possible that the interface protocols have changed or are in a different configuration from earlier tested units by VIDEOTEC. VIDEOTEC recommends a test prior to installation. VIDEOTEC will not be liable for any installation costs or lost revenues in the event a compatibility problem will occur.

I/O INTERFACE

Version with wiper

• Remote wiper activation: 1 input, dry contact NO

• Day/Night camera status: 1 input

• Wash system activation relay: 1 output, 60Vdc max or 30Vac max, 1A

• Illuminator activation relay: 1 output, 60Vdc max or 30Vac max, 1A

CAMERAS

Compatible cameras:

• Power consumption (assembly, camera and lens): 13W max

• Cameras dimensions/Lenses that can be installed (WxHxL): 80x82x245mm

(3.1x3.2x9.6in) max

• Minimum distance between camera and housing's window: 10mm (0.4in)

ENVIRONMENT

For indoors and outdoors installation

Operating temperature/Installation temperature: from -40°C (-40°F) up to +60°C (140°F)

Operating temperature/Installation temperature (MHX2...A-U, in 24Vac and with preinstalled camera by Videotec): from -40°C (-40°F) up to +54°C (129.2°F)

Relative humidity: from 5% up to 95%

CERTIFICATIONS

Electrical safety (CE): EN60950-1, IEC60950-1

Electromagnetic compatibility (CE): EN61000-6-4, EN61000-3-2, EN61000-3-3, EN50130-

4, EN55032 (Class A)

RoHS (CE): EN50581

Outdoor installation (CE): EN60950-22, ICE60950-22

IP protection degree (EN/IEC60529): IP66, IP67

Vibration test: EN50130-5, EN60068-2-6

UL certification (UL60950-1, CAN/CSA C22.2 No. 60950-1-07): cULus Listed

Electromagnetic compatibility (North America): FCC part 15 (Class A)

Level of protection Type (UL50E): 4X

CERTIFICATIONS - EXPLOSION-PROOF APPLICATIONS

ATEX (EN 60079-0+A11, EN 60079-1, EN 60079-31)

IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)

EAC EX (TR CU 012/2011)

INMETRO (ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-31)

KCs (Employment and labor department 2016-54)

UL listed for USA (UL 60079-0, UL 60079-1, UL 60079-31) (only versions in 24Vac with preinstalled camera by Videotec)

UL listed for Canada (CAN/CSA-C22.2 NO. 60079-0, CAN/CSA-C22.2 NO. 60079-1, CAN/

CSA-C22.2 NO. 60079-31) (only versions in 24Vac with pre-installed camera by Videotec)

For further details on certifications and markings, consult the relevant table.

WWW.VIDEOTEC.COM - DATA SHEETS

MAXIMUS-MHX_EN_2020-03-12

Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.

MBX1MAA

MBX2MAA

MBX3MAA

MBA1S5A

MBA2S5A

MBA3S5A

OCTEX3/4C

OCTEXA3/4C

OCTEXB3/4P

OCTEXBA3/4P

OCTEX3/4

OCTEXA3/4

OCTEXB1/2C

ACCESSORIES

WASEX2T4AT

WASEX2T4GOR

WASEX2T4IN

Tank 10l (2.6gal) with integrated manual pump controlled by ATEX certified solenoid valve, delivery head up to 20m (66ft) max, IN

24Vac/Vdc

Tank 10l (2.6gal) with integrated manual pump controlled by EAC

EX certified solenoid valve, delivery head up to 20m (66ft) max, IN

24Vac/Vdc

Tank 10l (2.6gal) with integrated manual pump controlled by

INMETRO certified solenoid valve, delivery head up to 20m (66ft) max, IN 24Vac/Vdc

Explosion-proof communication box in stainless steel, IN 230Vac, with EMC filter for marine certification

Explosion-proof communication box in stainless steel, IN 24Vac, with

EMC filter for marine certification

Explosion-proof communication box in stainless steel, IN 120Vac, with EMC filter for marine certification

Explosion-proof communication box in aluminium, IN 230Vac

Explosion-proof communication box in aluminium, IN 24Vac

Explosion-proof communication box in aluminium, IN 120Vac

Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex

Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex

Barrier cable gland in nickel-plated brass EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex

Barrier cable gland in nickel-plated brass EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex

Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable ATEX

Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable ATEX

Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex

OCTEXB1/2P

OCTEXBA1/2P

OCTEX1/2C

OCTEXS1/2C

OCTEXA1/2C

Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex

Barrier cable gland in nickel-plated brass EX 1/2" NPT, armoured cable IECEX-ATEX-EAC Ex

Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable

IECEX-ATEX-EAC Ex

Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable

IECEX-ATEX-EAC Ex

Cable gland in nickel-plated brass EX 1/2" NPT armoured cable

IECEX-ATEX-EAC Ex

OCTEX1/2-3/4P Cable glands reduction in nickel-plated brass Ex 3/4" - 1/2" NPT

IECEX-ATEX-EAC Ex

OCTEXP3/4C Conduit cable gland nickel-plated brass 3/4" NPT IECEX-ATEX- c CSA us - EAC Ex (operating temperature: from -60°C (-76°F) up to +80°C

(+176°F))

OEXPLUG1/2P

OEXPLUG3/4P

Plug EX 1/2“ NPT IECEX-ATEX-EAC Ex

Plug EX 3/4" NPT IECEX-ATEX-EAC Ex

USB485 USB-RS485 converter

For further details about cable glands part numbers, please refer to the relevant table.

BRACKETS AND ADAPTORS

MHXWBS AISI 316L stainless steel wall bracket

MPXCW

MPXCOL

MHXWFWCA

NXFWBT

AISI 316L stainless steel corner adapter module

AISI 316L stainless steel pole adapter module

AISI 316L stainless steel ball joint

AISI 316L stainless steel parapet mounting bracket

PACKAGE

Model Number

MHX

Weight Dimensions (WxHxL)

19kg (42lb) 58x34x22cm (23x13.4x8.7in) -

Master carton

ELECTRICAL RATING

Supply voltage

230Vac

120Vac

24Vac

12Vdc

WWW.VIDEOTEC.COM - DATA SHEETS

MAXIMUS-MHX_EN_2020-03-12

Max peak electrical ratings (comprising the max power dissipation of the end user camera/lens and heater)

0.34A, 50/60Hz, 80W

0.5A, 50/60Hz, 60W

2.2A, 50/60Hz, 53W

2.8A, 34W

Maximum power dissipation for end user fitted camera/lens

13W

13W

13W

13W

Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.

MAXIMUS MHX - CERTIFICATIONS AND MARKINGS

Certification

ATEX

Marking

II 2G Ex db IIC T6 Gb

II 2D Ex tb IIIC T85°C Db

IECEx

EAC Ex

INMETRO

Ex db IIC T6 Gb

Ex tb IIIC T85°C Db

1Ex d IIC T6 Gb X

Ex tb IIIC T85°C Db X

Ex db IIC T6 Gb

Ex tb IIIC T85°C Db

KCs

UL listed for USA (only 24Vac)

Ex d IIC T6

Ex tb IIIC T85°C

Class I, Zone 1, AEx db IIC T6

Zone 21, AEx tb IIIC T85°C

Class I, Division 2, Groups A, B, C, and D, T6,

Class II, Division 2, Group E, F and G, T6

UL listed for Canada (only 24Vac) Ex db IIC T6 Gb

Ex tb IIIC T85°C Db

Class I, Division 2, Groups A, B, C, and D, T6

Class II, Division 2, Group E, F and G, T6

1 UL Certifications only for 24Vac versions and with pre-installed camera by Videotec.

CABLE GLANDS AND ACCESSORIES 1/2" NPT

Type Certification

Barrier cable gland IECEX/ATEX/EAC Ex

Cable gland with gasket

Plug EX 1/2"NPT

IECEX/ATEX/EAC Ex

IECEX/ATEX/EAC Ex

Operating temperature Cable

-60°C (-76°F) /

+135°C (275°F)

Unarmoured cable

Armoured cable

-60°C / +100°C

(-76°F / +212°F)

Unarmoured cable

Unarmoured cable

-100°C (-148°F) /

+400°C (752°F)

Armoured cable

Ambient temperature

-40°C ≤ Ta ≤ +60°C

-40°C ≤ Ta ≤ +54°C

Model Number

OCTEXB1/2P

OCTEXBA1/2P

OCTEX1/2C

OCTEXS1/2C

OCTEXA1/2C

OEXPLUG1/2P

Diameter of the external cable

12.5 - 14.0mm

(0.5-0.55in)

15.5 - 21.1mm

(0.61-0.83in)

3.2 - 8.0mm (0.12-0.31in) –

6.5 - 11.9mm

(0.26 - 0.47in)

12.5 - 20.5mm

(0.49 - 0.8in)

CABLE GLANDS AND ACCESSORIES 3/4" NPT

Type

Barrier cable gland

Cable gland with gasket

Certification

IECEX/ATEX/EAC Ex

IECEX/ATEX/EAC Ex

ATEX

Operating temperature

-60°C (-76°F) /

+135°C (275°F)

-60°C / +100°C

(-76°F / +212°F)

-60°C / +80°C

(-76°F / +176°F)

-40°C / +100°C

(-40°F / +212°F)

Cable

Unarmoured cable

Armoured cable

Unarmoured cable

Armoured cable

Unarmoured cable

Armoured cable

Model Number

OCTEXB3/4P

OCTEXBA3/4P

OCTEX3/4C

OCTEXA3/4C

OCTEX3/4

OCTEXA3/4

Diameter of the external cable

17.8 - 20.0mm

(0.70-0.79in)

16.8 - 23.9mm

(0.66-0.94in)

13.0 - 20.2mm

(0.51-0.79in)

16.9 - 26.0mm

(0.66-1.02in)

14.0 - 17.0mm

(0.55-0.67in)

18.0 - 23.0mm

(0.71-0.91in)

– Plug EX 3/4"NPT

Conduit sealing fitting

Reduction 3/4"

NPT x 1/2" NPT

IECEX/ATEX/EAC Ex

IECEX-ATEX- c CSA us - EAC Ex

IECEX/ATEX/EAC Ex

-100°C (-148°F) /

+400°C (752°F)

-60°C / +80°C

(-76°F / +176°F)

-100°C (-148°F) /

+400°C (752°F)

OEXPLUG3/4P

OCTEXP3/4C

OCTEX1/2-3/4P

For a correct installation of the MHX/MHXT housing, cable entries and field wiring must be suitable for an operating temperature of at least +30°C above ambient.

Product Nr. Ending

…A

…A-U 1

Under armor cable diameter

10 - 14.3mm (0.4 - 0.56in)

Under armor cable diameter

11.1 - 19.7mm

(0.44 - 0.78in)

14 - 17mm (0.55 - 0.67in)

WWW.VIDEOTEC.COM - DATA SHEETS

MAXIMUS-MHX_EN_2020-03-12

Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.

AVAILABLE MODELS

Model Number

MHX1CS000A

MHX1CW000A

MHX2CS000A

MHX2CW000A

MHX3CS000A

MHX3CW000A

230Vac

24Vac

120Vac

Wiper

MAXIMUS MHX - CONFIGURATION OPTIONS

Voltage

MHX 1 230Vac

Certification

C IIC -40°C

2 24Vac

Options

S Without wiper

W With wiper

0 With sunshield

Day/Night camera 10x

00 Without camera

3 120Vac

1 MHX2...A-U, UL Certifications only for 24Vac versions and with pre-installed camera by Videotec. Operating temperature -40°C / + 54°C (-40°F / 129.2°F)

TECHNICAL DRAWINGS

The indicated measurements are expressed in millimetres.

M6

Sunshield

ATEX / IECEX / EAC

EX / INMETRO

A ATEX / IECEX /

INMETRO

A-U UL Listed for USA and

CANADA 1

A

Ø 75

A

Ø 75

177

80

USABLE

AREA

B  B

MAXIMUS MHX

Ø 102

245

USABLE AREA

422

A  A

483

B

150 139.5

B

WWW.VIDEOTEC.COM - DATA SHEETS

MAXIMUS-MHX_EN_2020-03-12

Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.

advertisement

Related manuals

Download PDF

advertisement