Videotec MAXIMUS MHX Ex-proof housing Tech Data Sheet
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
MAXIMUS MHX
EX-PROOF HOUSING
MHX+MHXWBS
DESCRIPTION
These explosion-proof housings for the MAXIMUS range have been certified and designed to meet the strictest standards regarding installation in potentially explosive environments, i.e. where there is the presence of gas and flammable dusts.
The MAXIMUS range ensures excellent performance for monitoring critical processes in areas that carry a risk of explosion, such as refineries, gas pipelines, oil tankers, offshore platforms, industrial processes, chemical industries, etc.
Equipped with heating, the housing has the same installation and operating temperatures, of between -40° C and + 60° (-40°F / +140°F).
In the version with wiper, MHX is equipped with an integrated telemetry receiver that allows, through the RS485 serial interface, to receive data from the remote control for the activation of the wiper / washer and for switching an eventual external illuminator.
The wiring is made easier thanks to the removable connectors on the circuit board.
The control board, with removable connectors, is also equipped with an input for the wiper activation through a dry contact.
The housing can eventually be controlled by VMS through a video encoder with RS485 serial port.
CERTIFICATIONS
MAIN FEATURES
Certifications Ex d for use in Zone 1 and 2, Group IIC (Gas), and in Zone Ex tb 21 and 22 (Dust)
Made of AISI 316L electropolished stainless steel
2 threaded holes ¾” NPT for use of cable glands or conduit
Integrated telemetry receiver for version with wiper
Sunshield and heater included
Power supply: 230Vac, 24Vac or 120Vac
Ambient temperature: from -40°C (-40°F) up to +60°C (140°F)
Internal usable area (WxHxL): 80x82x245mm (3.1x3.2x9.6in)
Options:
• Wiper
WWW.VIDEOTEC.COM - DATA SHEETS
MAXIMUS-MHX_EN_2020-03-12
Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.
TECHNICAL DATA
GENERAL
AISI 316L stainless steel construction
Passivated and electropolished external surfaces
Silicone O-ring seals
MECHANICAL
2 holes 3/4" NPT for cable entry
Sunshield
Unit weight: 16.5kg (36lb)
HOUSING'S WINDOW
Tempered window glass
• Usable diameter: 75mm (3.0in)
• Thick: 12mm (0.47in)
ELECTRICAL
Supply voltage/Current consumption:
• 230Vac, 0.34A, 50/60Hz
• 120Vac, 0.5A, 50/60Hz
• 24Vac, 2.2A, 50/60Hz
Heater (Ton 15°C±4°C (59°F±7°F), Toff 22°C±3°C (72°F±5°F))
COMMUNICATIONS
Serial interface: 1 RS-485 line, half-duplex
Addressable units: Up to 31, via dip-switch
Protocols:
• PELCO D: 2400baud, 9600baud
• VIDEOTEC MACRO: 9600baud, 38400baud
PELCO is registered trademark.
The product may be interfaced with devices not manufactured by VIDEOTEC. It is possible that the interface protocols have changed or are in a different configuration from earlier tested units by VIDEOTEC. VIDEOTEC recommends a test prior to installation. VIDEOTEC will not be liable for any installation costs or lost revenues in the event a compatibility problem will occur.
I/O INTERFACE
Version with wiper
• Remote wiper activation: 1 input, dry contact NO
• Day/Night camera status: 1 input
• Wash system activation relay: 1 output, 60Vdc max or 30Vac max, 1A
• Illuminator activation relay: 1 output, 60Vdc max or 30Vac max, 1A
CAMERAS
Compatible cameras:
• Power consumption (assembly, camera and lens): 13W max
• Cameras dimensions/Lenses that can be installed (WxHxL): 80x82x245mm
(3.1x3.2x9.6in) max
• Minimum distance between camera and housing's window: 10mm (0.4in)
ENVIRONMENT
For indoors and outdoors installation
Operating temperature/Installation temperature: from -40°C (-40°F) up to +60°C (140°F)
Operating temperature/Installation temperature (MHX2...A-U, in 24Vac and with preinstalled camera by Videotec): from -40°C (-40°F) up to +54°C (129.2°F)
Relative humidity: from 5% up to 95%
CERTIFICATIONS
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN61000-6-4, EN61000-3-2, EN61000-3-3, EN50130-
4, EN55032 (Class A)
RoHS (CE): EN50581
Outdoor installation (CE): EN60950-22, ICE60950-22
IP protection degree (EN/IEC60529): IP66, IP67
Vibration test: EN50130-5, EN60068-2-6
UL certification (UL60950-1, CAN/CSA C22.2 No. 60950-1-07): cULus Listed
Electromagnetic compatibility (North America): FCC part 15 (Class A)
Level of protection Type (UL50E): 4X
CERTIFICATIONS - EXPLOSION-PROOF APPLICATIONS
ATEX (EN 60079-0+A11, EN 60079-1, EN 60079-31)
IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
EAC EX (TR CU 012/2011)
INMETRO (ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-31)
KCs (Employment and labor department 2016-54)
UL listed for USA (UL 60079-0, UL 60079-1, UL 60079-31) (only versions in 24Vac with preinstalled camera by Videotec)
UL listed for Canada (CAN/CSA-C22.2 NO. 60079-0, CAN/CSA-C22.2 NO. 60079-1, CAN/
CSA-C22.2 NO. 60079-31) (only versions in 24Vac with pre-installed camera by Videotec)
For further details on certifications and markings, consult the relevant table.
WWW.VIDEOTEC.COM - DATA SHEETS
MAXIMUS-MHX_EN_2020-03-12
Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.
MBX1MAA
MBX2MAA
MBX3MAA
MBA1S5A
MBA2S5A
MBA3S5A
OCTEX3/4C
OCTEXA3/4C
OCTEXB3/4P
OCTEXBA3/4P
OCTEX3/4
OCTEXA3/4
OCTEXB1/2C
ACCESSORIES
WASEX2T4AT
WASEX2T4GOR
WASEX2T4IN
Tank 10l (2.6gal) with integrated manual pump controlled by ATEX certified solenoid valve, delivery head up to 20m (66ft) max, IN
24Vac/Vdc
Tank 10l (2.6gal) with integrated manual pump controlled by EAC
EX certified solenoid valve, delivery head up to 20m (66ft) max, IN
24Vac/Vdc
Tank 10l (2.6gal) with integrated manual pump controlled by
INMETRO certified solenoid valve, delivery head up to 20m (66ft) max, IN 24Vac/Vdc
Explosion-proof communication box in stainless steel, IN 230Vac, with EMC filter for marine certification
Explosion-proof communication box in stainless steel, IN 24Vac, with
EMC filter for marine certification
Explosion-proof communication box in stainless steel, IN 120Vac, with EMC filter for marine certification
Explosion-proof communication box in aluminium, IN 230Vac
Explosion-proof communication box in aluminium, IN 24Vac
Explosion-proof communication box in aluminium, IN 120Vac
Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex
Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex
Barrier cable gland in nickel-plated brass EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex
Barrier cable gland in nickel-plated brass EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex
Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable ATEX
Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable ATEX
Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
OCTEXB1/2P
OCTEXBA1/2P
OCTEX1/2C
OCTEXS1/2C
OCTEXA1/2C
Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
Barrier cable gland in nickel-plated brass EX 1/2" NPT, armoured cable IECEX-ATEX-EAC Ex
Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable
IECEX-ATEX-EAC Ex
Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable
IECEX-ATEX-EAC Ex
Cable gland in nickel-plated brass EX 1/2" NPT armoured cable
IECEX-ATEX-EAC Ex
OCTEX1/2-3/4P Cable glands reduction in nickel-plated brass Ex 3/4" - 1/2" NPT
IECEX-ATEX-EAC Ex
OCTEXP3/4C Conduit cable gland nickel-plated brass 3/4" NPT IECEX-ATEX- c CSA us - EAC Ex (operating temperature: from -60°C (-76°F) up to +80°C
(+176°F))
OEXPLUG1/2P
OEXPLUG3/4P
Plug EX 1/2“ NPT IECEX-ATEX-EAC Ex
Plug EX 3/4" NPT IECEX-ATEX-EAC Ex
USB485 USB-RS485 converter
For further details about cable glands part numbers, please refer to the relevant table.
BRACKETS AND ADAPTORS
MHXWBS AISI 316L stainless steel wall bracket
MPXCW
MPXCOL
MHXWFWCA
NXFWBT
AISI 316L stainless steel corner adapter module
AISI 316L stainless steel pole adapter module
AISI 316L stainless steel ball joint
AISI 316L stainless steel parapet mounting bracket
PACKAGE
Model Number
MHX
Weight Dimensions (WxHxL)
19kg (42lb) 58x34x22cm (23x13.4x8.7in) -
Master carton
ELECTRICAL RATING
Supply voltage
230Vac
120Vac
24Vac
12Vdc
WWW.VIDEOTEC.COM - DATA SHEETS
MAXIMUS-MHX_EN_2020-03-12
Max peak electrical ratings (comprising the max power dissipation of the end user camera/lens and heater)
0.34A, 50/60Hz, 80W
0.5A, 50/60Hz, 60W
2.2A, 50/60Hz, 53W
2.8A, 34W
Maximum power dissipation for end user fitted camera/lens
13W
13W
13W
13W
Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.
MAXIMUS MHX - CERTIFICATIONS AND MARKINGS
Certification
ATEX
Marking
II 2G Ex db IIC T6 Gb
II 2D Ex tb IIIC T85°C Db
IECEx
EAC Ex
INMETRO
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
1Ex d IIC T6 Gb X
Ex tb IIIC T85°C Db X
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
KCs
UL listed for USA (only 24Vac)
Ex d IIC T6
Ex tb IIIC T85°C
Class I, Zone 1, AEx db IIC T6
Zone 21, AEx tb IIIC T85°C
Class I, Division 2, Groups A, B, C, and D, T6,
Class II, Division 2, Group E, F and G, T6
UL listed for Canada (only 24Vac) Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
Class I, Division 2, Groups A, B, C, and D, T6
Class II, Division 2, Group E, F and G, T6
1 UL Certifications only for 24Vac versions and with pre-installed camera by Videotec.
CABLE GLANDS AND ACCESSORIES 1/2" NPT
Type Certification
Barrier cable gland IECEX/ATEX/EAC Ex
Cable gland with gasket
Plug EX 1/2"NPT
IECEX/ATEX/EAC Ex
IECEX/ATEX/EAC Ex
Operating temperature Cable
-60°C (-76°F) /
+135°C (275°F)
Unarmoured cable
Armoured cable
-60°C / +100°C
(-76°F / +212°F)
Unarmoured cable
Unarmoured cable
-100°C (-148°F) /
+400°C (752°F)
Armoured cable
–
Ambient temperature
-40°C ≤ Ta ≤ +60°C
-40°C ≤ Ta ≤ +54°C
Model Number
OCTEXB1/2P
OCTEXBA1/2P
OCTEX1/2C
OCTEXS1/2C
OCTEXA1/2C
OEXPLUG1/2P
Diameter of the external cable
12.5 - 14.0mm
(0.5-0.55in)
15.5 - 21.1mm
(0.61-0.83in)
3.2 - 8.0mm (0.12-0.31in) –
6.5 - 11.9mm
(0.26 - 0.47in)
12.5 - 20.5mm
(0.49 - 0.8in)
–
CABLE GLANDS AND ACCESSORIES 3/4" NPT
Type
Barrier cable gland
Cable gland with gasket
Certification
IECEX/ATEX/EAC Ex
IECEX/ATEX/EAC Ex
ATEX
Operating temperature
-60°C (-76°F) /
+135°C (275°F)
-60°C / +100°C
(-76°F / +212°F)
-60°C / +80°C
(-76°F / +176°F)
-40°C / +100°C
(-40°F / +212°F)
Cable
Unarmoured cable
Armoured cable
Unarmoured cable
Armoured cable
Unarmoured cable
Armoured cable
Model Number
OCTEXB3/4P
OCTEXBA3/4P
OCTEX3/4C
OCTEXA3/4C
OCTEX3/4
OCTEXA3/4
Diameter of the external cable
17.8 - 20.0mm
(0.70-0.79in)
16.8 - 23.9mm
(0.66-0.94in)
13.0 - 20.2mm
(0.51-0.79in)
16.9 - 26.0mm
(0.66-1.02in)
14.0 - 17.0mm
(0.55-0.67in)
18.0 - 23.0mm
(0.71-0.91in)
– Plug EX 3/4"NPT
Conduit sealing fitting
Reduction 3/4"
NPT x 1/2" NPT
IECEX/ATEX/EAC Ex
IECEX-ATEX- c CSA us - EAC Ex
IECEX/ATEX/EAC Ex
-100°C (-148°F) /
+400°C (752°F)
-60°C / +80°C
(-76°F / +176°F)
-100°C (-148°F) /
+400°C (752°F)
–
–
–
OEXPLUG3/4P
OCTEXP3/4C
OCTEX1/2-3/4P
–
–
For a correct installation of the MHX/MHXT housing, cable entries and field wiring must be suitable for an operating temperature of at least +30°C above ambient.
Product Nr. Ending
…A
…A-U 1
Under armor cable diameter
–
–
–
10 - 14.3mm (0.4 - 0.56in)
–
Under armor cable diameter
–
–
–
11.1 - 19.7mm
(0.44 - 0.78in)
–
14 - 17mm (0.55 - 0.67in)
–
–
–
WWW.VIDEOTEC.COM - DATA SHEETS
MAXIMUS-MHX_EN_2020-03-12
Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.
AVAILABLE MODELS
Model Number
MHX1CS000A
MHX1CW000A
MHX2CS000A
MHX2CW000A
MHX3CS000A
MHX3CW000A
230Vac
–
–
–
√
√
–
24Vac
–
–
√
√
–
–
120Vac
–
–
–
–
√
√
Wiper
√
–
√
–
√
–
MAXIMUS MHX - CONFIGURATION OPTIONS
Voltage
MHX 1 230Vac
Certification
C IIC -40°C
2 24Vac
Options
S Without wiper
W With wiper
0 With sunshield
Day/Night camera 10x
00 Without camera
3 120Vac
1 MHX2...A-U, UL Certifications only for 24Vac versions and with pre-installed camera by Videotec. Operating temperature -40°C / + 54°C (-40°F / 129.2°F)
TECHNICAL DRAWINGS
The indicated measurements are expressed in millimetres.
M6
Sunshield
√
√
√
√
√
√
√
√
√
√
√
ATEX / IECEX / EAC
EX / INMETRO
√
A ATEX / IECEX /
INMETRO
A-U UL Listed for USA and
CANADA 1
A
Ø 75
A
Ø 75
177
80
USABLE
AREA
B B
MAXIMUS MHX
Ø 102
245
USABLE AREA
422
A A
483
B
150 139.5
B
WWW.VIDEOTEC.COM - DATA SHEETS
MAXIMUS-MHX_EN_2020-03-12
Specifications subject to change without notice. © VIDEOTEC S.p.A. All rights reserved. The mentioned names of products or companies are trademarks or registered trademarks.
advertisement