BEA LZR-WIDESCAN User Guide
BEA LZR-WIDESCAN is a versatile sensor designed for industrial doors, providing motion, presence, and safety detection. It features adjustable settings for function, logic, and height triggering, accommodating various application requirements. The sensor's wide detection field and precise angle adjustment ensure accurate and reliable operation. With its rugged construction and easy installation, BEA LZR-WIDESCAN enhances safety and efficiency in industrial environments.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
QUICK GUIDE
!
Visit website for available languages of this document.
LZR-WIDESCAN
Motion, Presence, and Safety Sensor for Industrial Doors
(US version)
READ BEFORE BEGINNING INSTALLATION & SET-UP
!
Refer to the user’s guide for safety instructions and supplemental information.
Do not remove the protection film during the mechanical adjustments.
Remove it before launching a teach-in.
Following installation, always test for proper operation before leaving the premises.
1
OPENING THE SENSOR
Make sure the cover is not locked (red cover lock).
Pull the two legs on top in order to open the cover.
Completely remove the cover before installing the sensor.
2
ADJUST SETTINGS (IF NEEDED)
a. Adjust the sensor before mounting for easier access to the LCD screen. b. Adjust the function and logic of the outputs only if required by your application. c. Open the USB cap and power the sensor using a mini USB charger or battery.
Adjustments may also be made after Teach-In, if not using the USB.
Ex:
Quick Start
In-Out
Motion
OUT 1
I/O
Motion or PC
Out1Logic
Motion detection or presence detection in pull-cord zone
OUT 2
Out2Logic
Out 2 Function
Pres or Sfty
Out 2 Logic
Presence detection of object in presence or safety field
RELAY
Out 2 Logic
RelayFunction
HeightTrigger
RelayLogic
Detection of object if height > 7 ft 4 in
NO
Out2Function
Normally open Out2Logic
RelFunction
NC
Normally open RelayLogic
De-energized
>More
De-energized in no detection
3
MOUNTING & WIRING
Install the sensor in the left corner or the center of the door as high as possible (max. 32’).
Field width and field stop are limited by the mounting height
(1:1.2). Sensor will adjust field sizes to the max possible value for the mounting height.
H a b
D
W
Verify if the angle lock screw is positioned as indicated.
Unscrew if necessary.
Remove the mounting bracket from the sensor and secure it to the wall. You can also install the sensor directly without using the mounting bracket.
c d
Position the sensor horizontally and secure the sensor to the mounting bracket.
Plug in the connector and pass the cable through the cable passage without making a loop.
OUT 1
*
RD
BK
YE
YE
POWER
SAFETY
OUT 2
*
RELAY
*
COM
NO
NC
PK
PK
PRESENCE
GN
WH-GN
GN-GREY
MOTION/PULL-CORD
BU
BU
TEST
Connect the wires accordingly.
* output status powered during non-detection with factory values
5
INSTALL
Launch teach-in after angle adjustment.
All presence/safety outputs are activated.
4
ANGLE ADJUSTMENT
Power the sensor. The LCD screen shows the detection display.
Activate the 2 visible laser spots by double-clicking OK or using the remote control sequence shown to the right.
The visible laser beams stay activated for 15 minutes or can be turned off by double-clicking OK or UNLOCK > MAGIC WAND > MAGIC WAND on the remote control.
Do not look directly into the laser emitter or the visible red laser beams.
Remove the blue protection film from the laser window.
F1
+
F2
C
D
PRESS
2X
OR
Make sure the curtain is parallel to the door by adjusting one or both screws on the side.
When the safety function is required, the red spots should be as close to the door as possible.
Negative angles reduce the depth of the detection fields.
Position the curtain closer to or farther away from the door by turning the screw at the top.
Launch the POSITION WIZARD to position the detection field correctly in front of the door.
LONG OK
1. Push and hold OK to launch the POSITION WIZARD.
2. Rotate the sensor in order to align the center of the red spots with the center of the door. Push OK.
3. Rotate the sensor until the LCD screen validates the position. Push OK to exit.
NOTE: It is best to make minor adjustments to the sensor and then verify that you are not obstructing the pattern. Verify that both red spots are on the floor with no interference.
Lock the sensor position by tightening the angle lock screw (see step 6A).
5
TEACH-IN: INSTALL
The teach-in zone (square in front of the 2 visible spots) should be completely free and flat.
This teach-in must be launched each time one of the sensor angles has been changed.
Make sure the protection film is removed and the cover is closed or removed.
1. Launch a teach-in by LCD or remote control (Quick Start > Teach-in > Install).
LCD
Quick Start
In-Out
QS
TeachIn
Presettings
TeachIn
Install
REMOTE
CONTROL
F1
+
F2
C
D
2. Clear the teach-in zone in front of the sensor.
The learning process starts. Position, angle, and height are learned; the background is analyzed and the teach-in ends successfully. If this is not accomplished, refer to the
TROUBLESHOOTING section in the User’s Guide (75.5916).
...
....
..
SETTINGS FOR 3 MAIN FUNCTIONS
MOTION WIDTH
000 – 460 inches
DEPTH
PRESENCE WIDTH
000 – 460 inches
DEPTH
SAFETY
WIDTH
000 – 460 inches
DEPTH
6 a
CLOSING THE SENSOR
b c
5
Lock the lateral angle by firmly fastening the angle lock screw.
Reclip the sensor cover horizontally and close it as indicated.
Lock the cover by turning the lock screw clockwise.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore,
BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
Tech Support & Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
advertisement