Models Outdoor Unit FSHSR09A1A FSHSR12A1A FSHSR18A3A FSHSR24A3A Content Operation Notices Precautions ..........................................................................................................1 Parts Name ..........................................................................................................6 Installation Notice Installation dimension diagram.............................................................................7 Safety precautions for installing and relocating the unit ................................... 8 Tools for installation..............................................................................................9 Selection of installation location ...........................................................................9 Requirements for electric connection .................................................................10 Installation Installation of outdoor unit ..................................................................................11 Vacuum pumping ...............................................................................................15 Leakage detection ..............................................................................................15 Check after installation .......................................................................................16 Test and operation Test operation ....................................................................................................16 Attachment Configuration of connection pipe .......................................................................17 Pipe expanding method......................................................................................19 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherwise, it may cause serious damage or personal injury or death. Explanation of Symbols DANGER Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage. Indicates a hazard that would be assigned a signal word WARNING or CAUTION. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons. 1.Damage to product due to improper use or misuse of the product. 2.Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer. 3.After verification, the defect of product is directly caused by corrosive gas. 4.After verification, defects are due to improper operation during transportation of product. 5.Operate, repair, maintain the unit without abiding by instruction manual or related regulations. 6.After verification, the problem or dispute is caused by the quality specification or performance of parts and components that produced by other manufacturers. 7.The damage is caused by natural disasters, improper installation environment or force majeure. Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not connect air conditioner to multi-purpose socket. Otherwise, it may cause fire hazard. Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Do not spray water on indoor unit. It may cause electric shock or malfunction. After removing the filter, do not touch fins. Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard. 1 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage. Do not block air outlet or air inlet. It may cause malfunction. Do not spill water on the remote controller, otherwise the remote controller may be broken. When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service. ● Power cord is overheating or damaged. ● There’s abnormal sound during operation. ● Circuit break trips off frequently. ● Air conditioner gives off burning smell. ● Indoor unit is leaking. If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard. When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal. Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury. 2 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break. If not, it may cause malfunction. An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring. Including an circuit break with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock. Don't use unqualified power cord. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring may result in electric shock, fire hazard or malfunction. Please install proper power supply cables before using the air conditioner. Properly connect the live wire, neutral wire and grounding wire of power socket. Be sure to cut off the power supply before proceeding any work related to electricity and safety. 3 Precautions WARNING Do not power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. The appliance shall be installed in accordance with national wiring regulations. Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only. Air conditioner must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes. The grounding resistance should comply with national electric safety regulations. All wires of indoor unit and outdoor unit should be connected by a professional. 4 Precautions WARNING Caution: This equipment is not intended for use during construction. The use of equipment during construction could result in premature failure of the components and/ or system and is in violation of our standard warranty guidelines and may result in the suspension or termination of the warranty. Ensure that proper N.E.C. code is followed. If you need to relocate the air conditioner to another place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage. Select a location which is out of reach for children and far away from animals or plants. If it is unavoidable, please add the fence for safety purpose. The indoor unit should be installed close to the wall. Working temperature range Maximum cooling Maximum heating Indoor side DB/WB(°F/°C) Outdoor side DB/WB(°F/°C) 115/75(46/24) 80/67(26.7/19.4) 75/65(24/18) 80/-(26.7/-) NOTICE: The operating temperature range (outdoor temperature) for cooling only unit is 0°F (-18℃)~ 115°F(46℃ ); for heat pump unit is-4°F (-20℃)~115°F(45℃). 5 Parts Name Outdoor Unit air inlet Connection wire air outlet NOTICE: Actual product may be different from above graphics, please refer to actual products. 6 Installation dimension diagram 20in Above Space to the obstruction Air inlet side e 12 Space to the wall in A bo ve 12in Above 0709 in ov Ab 20in Above Air outlet side Space to the wall Drainage pipe 7 Safety precautions for installing and relocating the unit To ensure safety, please be mindful of the following precautions. Warning When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury. ! " #$"%$ & ! ' ( ) " * + , + * -$$ + * ** . * ** + ' * ( ' ! ( / * * . 0,1 * Tools for installation 1 Level 2 Screw driver 3 Impact drill 4 Drill 5 Pipe expander 6 Torque wrench 7 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 12 14 Measuring tape 13 Note: Selection of installation location Indoor unit Basic requirement Outdoor unit 9 Requirements for electric connection Safety precaution ) 2 , 3 # % 4 * - 5 * + Grounding requirement ) , 2 6 7& & # & 0 )$ Installation of outdoor unit Step one: Mounting of the outdoor unit 1. Select installation base on building material. 2. Choose the correct mounting hardware for application. and operable manner. 2 above the ground for heat pump operation, this will allow proper water drainage. anchors for your mounting material. at least 2 above the floor Step two: install drain joint 1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below. 2. Connect the drain hose into the drain vent. drain vent Drain hose 1. Place the outdoor unit on the support. 2. Fix the foot holes of outdoor unit with bolts. foot holes chassis outdoor drain joint 11 foot holes Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe. 3. Tighten the union nut with torque wrench by referring to the sheet below. torque Hex nut diameter Tightening (N.m) 1/4'' 15~20 3/8'' 30~40 1/2'' 45~55 5/8'' 60~65 3/4'' 70~75 liquid pipe liquid valve gas pipe gas valve 2. Pretighten the union nut with hand. pipe joint union nut 1. Remove the wire clip; connect the power connection wire and signal control wire (only for cooling and heating unit) to the wiring terminal according to the color; fix them with screws. 18 07 09 12K: N(1) L1 24K: N(1) 2 3 L1 L2 L2 white (blue) white red (blue) black (brown) green (yellowgreen) green red black (brown) (yellowgreen) white black green (blue) (brown) (yellowgreen) L1 L2 lock nut POWER Indoor unit connection Finish conduit 12 N(1) 2 3 Indoor unit connection G green(yellow-green) white(blue) L2 black(brown) L1 POWER Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip. Note: Step six: Arrange piping 1. The pipes should be placed along the wall, bent reasonably and hidden wall 2. If outdoor unit placement is higher than wall penetration, create a drip loop in the line-set to keep water from entering the building. $ drain hose Outdoor Condensate Drainage (only for Heat pump unit) During heating operation, the condensate and defrosting water should be drained out reliably through the drain hose. Install the outdoor dr on the base plate and attach the drain hose to the connector so that the waste water formed in the outdoor unit can be drained out. The hole dia Whether to plug other holes will be determined by the dealers to actual conditions. 07 09 12K UNIT: 18K UNIT: drain hole Drain-water hole Bottom frame !"# Drain-water hole drain hole Bottom frame Drain-water hole Bottom frame 13 Installation of outdoor unit The 18K、24K UNIT drainage hole consists of two Φ25 and two kidney holes (see the fig.1). The drain plug consists of one Φ25 and two kidney plugs. (The figures in this manual may be different with the material objects, please refer to the material objects for reference) Drain plug drain holes Drain connecter Hose (available commercially, inner dia. 16mm) drain holes Fig.1 14 drain holes Vacuum pumping Use vacuum pump 1. Remove the valve caps on liquid valve the liquid valve and gas 8 & Lo Hi valve and the nut of refrigas valve gerant charging vent. refrigerant valve cap 2. Connect the charging hose charging 8 & to the refrigerant charging of gas nut of refrigerant valve and then connect the charging other charging hose to the vacuum pump vacuum pump. 3. Open the 8 & com9 pletely and operate for 10-15min to check if the pressure of 8 & re- mains in -0.1MPa. close 4. Close the vacuum pump open and maintain for1-2min to check if the pressure of 8 & remains in -0.1MPa. If the pressure decreases, there may be leakage. 5. Remove the 8 & , open the valve core of liquid valve and gas valvecompletely with 9 6. Tighten the screw caps of valves and refrigerant charging . 7. Reinstall the handle. Leakage detection 1. With leakage detector: Check if there is leakage with leakage detector. 2. With soap water: If leakage detector is not available, please use soap water for leakage detection. Apply soap water at the suspected position and keep the soap water for more than 3min. * ** : " )- Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. Is water drained well? It may cause condensation and water dripping. Is the voltage of power supply according to the voltage marked on the nameplate? It may cause malfunction or damaging the parts. Is electric wiring and pipeline installed correctly? It may cause malfunction or damaging the parts. Is the unit grounded securely? It may cause electric leakage. Does the power cord follow the speci- It may cause malfunction or damaging the parts. Is there any obstruction in the air inlet and outlet? (heating) capacity. The dust and sundries caused during installation are removed? It may cause malfunction or damaging the parts. The gas valve and liquid valve of connection pipe are open completely? (heating) capacity. Is the inlet and outlet of piping hole been covered? It may cause insufficient cooling (heating) capacity or waster eletricity. Test operation 1. Preparation of test operation The client approves the air conditioner. & *+ * ient. 2. Method of test operation < r, press ON/OFF button on the remote controller to start operation. <=>@J AUTO, COOL, DRY, FQXJAT to check whether the operation is normal or not. !* Z[℉ 16ć , the air conditioner can’t start cooling. 16 Configuration of connection pipe 1. Standard length of connection pipe ● )- 22- 2% 2.Min. length of connection pipe is >. 3.Max. length of connection pipe. Unit: Max length of connection pipe Cooling capacity Max length of connection pipe Cooling capacity Max length of connection pipe 5000Btu/h %- 24000Btu/h ;- 7000Btu/h %- 28000Btu/h >$ 9000Btu/h %- 36000Btu/h >$ 12000Btu/h <$ 42000Btu/h >$ 18000Btu/h ;- 48000Btu/h >$ 4. 9 * ( " ● 9 " * ( ## 2- - )< ● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe): 9 = ( ( ● Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant charging amount per foot is different according to the diameter of liquid pipe. See the following sheet. ); Configuration of connection pipe Diameter of connection pipe Outdoor unit charge Liquid pipe Gas pipe 1/4'' 3/8'' or 1/2'' 0.71 1/4'' or 3/8'' 5/8'' or 3/4'' 1.76 1/2'' 3/4'' or 7/8'' 4.23 Cooling and heating(oz/g) 5/8'' 1 '' or 1 1/4'' 4.23 3/4'' _ 8.82 7/8'' _ 12.35 18 Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port J` ` r. the distance of indoor unit and outdoor unit. \ ] hard mold expander r. pipe pipe pipe cutter leaning uneven Note: {Q{fferent according to the diameter, please refer to the sheet below: burr A( ) Outer diameter B: Remove the burrs ^ prevent the burrs from getting into the pipe. pipe shaper downwards Max Min [{Z$Z $$- $$# { $$< $$% [{[$[ $$; $$% {[$[Z $>% $$> F: Inspection \ | ] +*` !* + }` port again according to the steps above. C: Put on suitable insulating pipe D: Put on the union nut ^ connection pipe and outdoor valve; install the union nut on the pipe. smooth surface improper expanding union pipe leaning pipe ] l )> damaged surface crack uneven thickness Friedrich Air Conditioning Co. 10001 Reunion Place, Suite 50an Antonio, Texas 78216 1.800.541.6645 www.friedrich.com 66129933951
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement