Friedrich FSHSR24A3A, FSHSR09A1A, FSHSR18A3A, FSHSR12A1A Operating instructions

Friedrich FSHSR24A3A,  FSHSR09A1A, FSHSR18A3A,  FSHSR12A1A Operating instructions
Models
Outdoor Unit FSHSR09A1A FSHSR12A1A
FSHSR18A3A FSHSR24A3A
Content
Operation Notices
Precautions ..........................................................................................................1
Parts Name ..........................................................................................................6
Installation Notice
Installation dimension diagram.............................................................................7
Safety precautions for installing and relocating the unit ................................... 8
Tools for installation..............................................................................................9
Selection of installation location ...........................................................................9
Requirements for electric connection .................................................................10
Installation
Installation of outdoor unit ..................................................................................11
Vacuum pumping ...............................................................................................15
Leakage detection ..............................................................................................15
Check after installation .......................................................................................16
Test and operation
Test operation ....................................................................................................16
Attachment
Configuration of connection pipe .......................................................................17
Pipe expanding method......................................................................................19
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service center
to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit.
Otherwise, it may cause serious damage or personal injury or death.
Explanation of Symbols
DANGER
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
NOTICE
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or
property loss is caused by the following reasons.
1.Damage to product due to improper use or misuse of the product.
2.Alter, change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer.
3.After verification, the defect of product is directly caused by corrosive gas.
4.After verification, defects are due to improper operation during transportation of
product.
5.Operate, repair, maintain the unit without abiding by instruction manual or related
regulations.
6.After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers.
7.The damage is caused by natural disasters, improper installation environment or
force majeure.
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
1
Precautions
WARNING
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
2
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table. Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the requirement
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the
air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
3
Precautions
WARNING
Do not power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
Air conditioner must be properly grounding with specialized
grounding device by a professional. Please make sure it is
always grounded effectively, otherwise it may cause electric
shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
All wires of indoor unit and outdoor unit should be
connected by a professional.
4
Precautions
WARNING
Caution: This equipment is not intended for use during
construction. The use of equipment during construction
could result in premature failure of the components and/
or system and is in violation of our standard warranty
guidelines and may result in the suspension or
termination of the warranty.
Ensure that proper N.E.C. code is followed.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants. If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(°F/°C) Outdoor side DB/WB(°F/°C)
115/75(46/24)
80/67(26.7/19.4)
75/65(24/18)
80/-(26.7/-)
NOTICE:
The operating temperature range (outdoor temperature) for cooling only unit is
0°F (-18℃)~ 115°F(46℃ ); for heat pump unit is-4°F (-20℃)~115°F(45℃).
5
Parts Name
Outdoor Unit
air inlet
Connection wire
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
6
Installation dimension diagram
20in Above
Space to the obstruction
Air inlet side
e
12
Space to the wall
in A
bo
ve
12in Above
0709
in
ov
Ab
20in Above
Air outlet side
Space to the wall
Drainage pipe
7
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause
system pressure rise or compressor rupture, resulting in injury.
!
" #$"%$ & ! '
( ) " * + , + * -$$ + * ** . * ** +
' * ( ' ! ( / * * . 0,1 * Tools for installation
1 Level
2 Screw driver
3 Impact drill
4 Drill
5 Pipe expander
6 Torque wrench
7
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11
12
14 Measuring tape
13
Note:
Selection of installation location
Indoor unit
Basic requirement
Outdoor unit
9
Requirements for electric connection
Safety precaution
) 2 , 3 # % 4 * - 5 * + Grounding requirement
) , 2 6 7& & # & 0 )$
Installation of outdoor unit
Step one: Mounting of the outdoor unit
1. Select installation base on building material.
2. Choose the correct mounting hardware for application.
and operable manner.
2
above the ground for heat pump operation,
this will allow proper water drainage.
anchors for your mounting material.
at least 2 above the floor
Step two: install drain joint
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain vent.
drain vent
Drain hose
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
foot holes
chassis
outdoor drain joint
11
foot holes
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
3. Tighten the union nut with torque
wrench by referring to the sheet
below.
torque
Hex nut diameter Tightening
(N.m)
1/4''
15~20
3/8''
30~40
1/2''
45~55
5/8''
60~65
3/4''
70~75
liquid pipe
liquid
valve
gas pipe
gas valve
2. Pretighten the union nut with
hand.
pipe joint
union nut
1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the
color; fix them with screws.
18
07 09 12K:
N(1) L1
24K:
N(1)
2
3
L1
L2
L2
white
(blue)
white
red
(blue) black (brown)
green
(yellowgreen)
green
red
black (brown) (yellowgreen)
white black green
(blue) (brown) (yellowgreen)
L1 L2
lock nut
POWER
Indoor unit connection
Finish
conduit
12
N(1)
2
3
Indoor unit connection
G
green(yellow-green)
white(blue)
L2
black(brown)
L1
POWER
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip.
Note:
Step six: Arrange piping
1. The pipes should be placed along the wall,
bent reasonably and hidden
wall
2. If outdoor unit placement is higher than wall
penetration, create a drip loop in the line-set to
keep water from entering the building.
$ drain hose
Outdoor Condensate Drainage (only for Heat pump unit)
During heating operation, the condensate and
defrosting water should be drained out reliably
through the drain hose. Install the outdoor dr on the
base plate and attach the drain hose to the connector so that the waste water formed in the
outdoor unit can be drained out. The hole dia Whether to plug other holes will be determined
by the dealers to actual conditions.
07 09 12K UNIT:
18K UNIT:
drain hole
Drain-water hole
Bottom frame
!"#
Drain-water hole
drain hole
Bottom frame
Drain-water hole
Bottom frame
13
Installation of outdoor unit
The 18K、24K UNIT drainage hole consists of two Φ25 and two kidney
holes (see the fig.1). The drain plug consists of one Φ25 and two kidney plugs.
(The figures in this manual may be different with the material objects, please refer
to the material objects for reference)
Drain plug
drain holes
Drain connecter
Hose (available
commercially,
inner dia. 16mm)
drain holes
Fig.1
14
drain holes
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on
liquid valve
the liquid valve and gas
8 & Lo Hi
valve and the nut of refrigas valve
gerant charging vent.
refrigerant
valve cap
2. Connect the charging hose
charging 8 & to the refrigerant charging of gas nut of refrigerant
valve and then connect the charging other charging hose to the
vacuum pump
vacuum pump.
3. Open the 8 & com9 pletely and operate for
10-15min to check if the
pressure of 8 & re-
mains in -0.1MPa.
close
4. Close the vacuum pump
open
and maintain for1-2min to
check if the pressure of 8 & remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the 8 & , open the valve core of liquid valve and gas
valvecompletely with 9 6. Tighten the screw caps of valves and refrigerant charging .
7. Reinstall the handle.
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. * ** : " )-
Check after installation
Items to be checked
Possible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
(heating) capacity.
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci-
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
connection pipe are open completely?
(heating) capacity.
Is the inlet and outlet of piping hole
been covered?
It may cause insufficient cooling
(heating) capacity or waster eletricity.
Test operation
1. Preparation of test operation
The client approves the air conditioner.
& *+ * ient.
2. Method of test operation
< r, press ON/OFF button on the remote controller to start
operation.
<=>@J AUTO, COOL, DRY, FQXJAT to check
whether the operation is normal or not.
!* Z[℉ 16ć , the air conditioner can’t
start cooling.
16
Configuration of connection pipe
1. Standard length of connection pipe
● )- 22- 2% 2.Min. length of connection pipe is >.
3.Max. length of connection pipe.
Unit: Max length of connection pipe
Cooling
capacity
Max length
of connection pipe
Cooling
capacity
Max length
of connection pipe
5000Btu/h
%-
24000Btu/h
;-
7000Btu/h
%-
28000Btu/h
>$
9000Btu/h
%-
36000Btu/h
>$
12000Btu/h
<$
42000Btu/h
>$
18000Btu/h
;-
48000Btu/h
>$
4. 9 * ( " ● 9 " * ( ## 2- - )< ● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
9 = ( (
● Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per foot is different according to the diameter of liquid pipe. See the
following sheet.
);
Configuration of connection pipe
Diameter of connection pipe
Outdoor unit charge
Liquid pipe
Gas pipe
1/4''
3/8'' or 1/2''
0.71
1/4'' or 3/8''
5/8'' or 3/4''
1.76
1/2''
3/4'' or 7/8''
4.23
Cooling and heating(oz/g)
5/8''
1 '' or 1 1/4''
4.23
3/4''
_
8.82
7/8''
_
12.35
18
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
E: Expand the port
J` ` r.
the distance of indoor unit and
outdoor unit.
\ ] hard
mold
expander
r.
pipe
pipe
pipe cutter
leaning
uneven
Note:
{Q{fferent according to the
diameter, please refer to the sheet
below:
burr
A( )
Outer diameter
B: Remove the burrs
^ prevent the burrs from getting into
the pipe.
pipe
shaper
downwards
Max
Min
[€{Z$Z‚
$$-
$$#
‚€ƒ{„
$$<
$$%
[€{[$[
$$;
$$%
€ƒ{[ƒ$[Z
$>%
$$>
F: Inspection
\ | ] +*` !* + }` port again according to the steps
above.
C: Put on suitable insulating pipe
D: Put on the union nut
^ connection pipe and outdoor valve;
install the union nut on the pipe.
smooth surface
improper expanding
union pipe
leaning
pipe
] l
)>
damaged
surface
crack
uneven
thickness
Friedrich Air Conditioning Co.
10001 Reunion Place, Suite 50an Antonio, Texas 78216
1.800.541.6645
www.friedrich.com