Monogram ZV925SLSS 36" Glass Canopy Island Hood Installation Instructions
Monogram ZV925SLSS 36” Island Chimney Vent Hood brings a professional look and powerful performance to your kitchen. Its sleek stainless steel exterior and two powerful blowers quickly remove smoke, grease, and odors, while the halogen lights illuminate your cooktop for precise cooking. The hood can be vented outside or recirculated to fit your needs, and it comes with dishwasher-safe filters for easy cleaning. Additional features include a time-delay auto shut-off, three-speed fan control, and a heat sensor that automatically adjusts the fan speed based on the temperature.
PDF
Document
Advertisement
Advertisement
INSTALLATION INSTRUCTIONS 36” Island Chimney Vent Hood ZV925 MONOGRAM.COM Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Ŷ IMPORTANT — Save these instructions for local inspector’s use. IMPORTANT — Observe all governing codes and ordinances. ŶNote to Installer — Be sure to leave these instructions with the Consumer. ŶNote to Consumer — Keep these instructions with your Owner’s Manual for future reference. ŶSkill Level — Installation of this appliance requires basic mechanical and electrical skills. ŶCompletion Time — 1 to 3 Hours. Ŷ3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW covered under the warranty. Ŷ)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW monogram.com. Ŷ)RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca Ŷ)RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW monogram.com/use-and-care/parts. Ŷ CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury RUGDPDJHWRWKHSURGXFW TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION. ATTENTION À cause du poids et de la taille de ces hottes et pour reduire le risque de blessures et GHGRPPDJHVIL FAUT DEUX PERSONNES POUR FAIRE L’INSTALLATION CORRECTEMENT. WARNING To reduce the risk of fire or electrical VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ from original factory wiring could result in damage to the unit and/or create an electrical safety hazard. AVERTISSEMENT 3RXUUpGXLUHOHULVTXH G¶LQFHQGLHRXGHFKRFpOHFWULTXHLOQHIDXWSDV XWLOLVHUFHWWHKRWWHDYHFXQUpJXODWHXUGHYLWHVVH pOHFWURQLTXHH[WHUQH7RXWHPRGLILFDWLRQGHFHW\SHGX branchement d’usine peute endommager l’appareil ou FUpHUXQULVTXHGHFKRFpOHFWULTXH TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. WARNING 725('8&(7+(5,6.2)),5( (/(&75,&$/6+2&.25,1-85<723(56216 2%6(59(7+()2//2:,1* $8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW the manufacturer. %%HIRUHVHUYLFLQJRUFOHDQLQJWKHXQLWVZLWFKWKH power off at the service panel and lock the service disconnecting means to prevent the power from EHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFH GLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\ IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ to the service panel. AVERTISSEMENT 32855e'8,5(/(5,648( '¶,1&(1',('(&+2&e/(&75,48(28'( %/(6685(6,/)$872%6(59(5/(65(*/(6 68,9$17(6 $8WLOLVHUFHWDSSDUHLOXQLTXHPHQWGHODPDQLpUH SUpYXHSDUOHIDEULFDQW(QFDVGHTXHVWLRQ consulter le fabricant. %$YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSHU O¶DOLPHQWDWLRQpOHFWULTXHDXGLVMRQFWHXUHWYHUURXLOOHU OHSDQQHDXGXGLVMRQFWHXUSRXUpYLWHUODPLVHVRXV tension accidentelle. S’il n’est pas possible de YHUURXLOOHUOHSDQQHDXGXGLVFRQFWHXUDWWDFKHUXQ SODFDUGRXXQHpWLTXHWWHWUpVYLVLEOHDXSDQQHDX Ŷ)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV Ŷ6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO wiring must be done by qualified person(s) in accordance with all applicable codes and standards including fire-rated construction. Ŷ6XIILFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG H[KDXVWLQJRIJDVHVWKURXJKWKHIOXH FKLPQH\ RIIXHO EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ the heating equipment manufacturer’s guidelines and safety standards such as those published by WKH1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ 1)3$ DQG WKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG $LU&RQGLWLRQLQJ(QJLQHHUV $6+5$( DQGWKHORFDO FRGHDXWKRULWLHV:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS (replacement) air system in accordance with local EXLOGLQJFRGHUHTXLUHPHQWV9LVLW*($SSOLDQFHVFRP for available makeup air solutions. Ŷ/RFDOFRGHVYDU\,QVWDOODWLRQRIHOHFWULFDOFRQQHFWLRQV and grounding must comply with applicable codes. ,QWKHDEVHQFHRIORFDOFRGHVWKHYHQWVKRXOGEH LQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH $16,1)3$RUODWHVWHGLWLRQ CAUTION To reduce risk of fire and to properly H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR DWWLFVFUDZOVSDFHVRUJDUDJHV ATTENTION Il faut prendre soin d’installer XQFRQGXLWYHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXH G¶LQFHQGLHHWSRXYRLUpYDFXHUO¶DLUFRUUHFWHPHQW,O QHIDXWSDVpYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDV pYDFXHUO¶DLUGDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXU XQSODIRQGRXXQJUHQLHUXQHVSDFHVDQLWDLUHRXXQ garage. READ AND SAVE THESE INSTRUCTIONS 2 49-80329 Rev. 5 Design Information CONTENTS Design Information 3URGXFW'LPHQVLRQV ...................................................... 3 Advance Planning $GYDQFH3ODQQLQJ ........................................................ 4 3RZHU6XSSO\ ............................................................... 4 'XFW)LWWLQJV ................................................................ 5 Installation Preparation Tools and Materials Required ....................................... 6 5HPRYHWKH3DFNDJLQJ ................................................ 6 Installation Height ......................................................... 3DUWV3URYLGHG .............................................................. 8 Installation Preparation Construct Ceiling Support ............................................. Installation Instructions—Vented to the Outside 6WHS0RXQW7HPSODWH .............................................. 12 6WHS$GMXVW)UDPH+HLJKW ....................................... 12 6WHS&XW'XFWWR/HQJWKIRU9HQWHG,QVWDOODWLRQ...... 13 6WHS,QVWDOOWKH6XSSRUW)UDPH ............................... 13 6WHS,QVWDOO+RRG$WWDFKPHQW6FUHZV..................... 13 6WHS0RXQWWKH+RRGRQWRWKH6XSSRUW .................. 14 6WHS&RQQHFW&DEOHV .............................................. 14 6WHS&RQQHFW(OHFWULFDO ........................................... 15 6WHS3UHSDUHWKH'XFW&RYHUV ................................ 16 6WHS,QVWDOO8SSHU'XFW&RYHU .............................. 16 6WHS,QVWDOO/RZHU'XFW&RYHU .............................. 6WHS,QVWDOO'XFW&RYHU7ULP ................................. 6WHS,QVWDOO0HWDO)LOWHU.......................................... 6WHS)LQDOL]H,QVWDOODWLRQ ....................................... Installation Instructions—Recirculating 6WHS0RXQW7HPSODWH .............................................. 18 6WHS$GMXVW)UDPH+HLJKW ....................................... 18 6WHS,QVWDOO$LU'HIOHFWRU&XW'XFW for Recirculating Operation ............................. 6WHS,QVWDOO8SSHU6XSSRUW)UDPH .......................... 6WHS,QVWDOO/RZHU6WUXFWXUHWR8SSHU6WUXFWXUH ..... 6WHS,QVWDOO%ORZHU0RWRU ........................................ 6WHS,QVWDOO+RRG$WWDFKPHQW6FUHZV..................... 6WHS0RXQWWKH+RRGRQWRWKH6XSSRUW .................. 6WHS&RQQHFW&DEOHV .............................................. 21 6WHS&RQQHFW(OHFWULFDO ......................................... 21 6WHS3UHSDUHWKH'XFW&RYHUV .............................. 22 6WHS,QVWDOO8SSHU'XFW&RYHU .............................. 22 6WHS,QVWDOO/RZHU'XFW&RYHU .............................. 22 6WHS,QVWDOO'XFW&RYHU7ULP ................................. 23 6WHS,QVWDOO)LOWHUV.................................................. 23 6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 23 PRODUCT DIMENSIONS *Height to *Height ceiling to Ceiling 24" min.* PD[ 3/4" 32 1/4" 9/16" 27 7/8" 35 7KHVXSSOLHGGXFWFRYHUILWV¶´WR¶FHLOLQJKHLJKWV )RU¶´WR¶´FHLOLQJVRUGHU=; 36" min. ([DFWLQVWDOODWLRQ height depends on ceiling height. These vent hoods are supplied with a support frame for FHLOLQJKHLJKWVRI¶´WR¶´ Decorative duct covers conceal the ductwork running from the top of the hood to the ceiling. =;DFFHVVRU\LVDYDLODEOHIRUFHLOLQJKHLJKWVRI ¶´WR¶´ NOTE: Installation height should be measured from the cooking surface to the bottom of the outer glass portion of the hood. 49-80329 Rev. 5 7KLVKRRGPXVWEHLQVWDOOHG´PLQDQG´PD[ above the cooking surface. The cooking surface should EHDWOHDVW´DERYHWKHIORRU 7KLVKRRGPD\EHYHQWHGWRWKHRXWGRRUVRULWFDQEH installed for recirculating operation. This hood can be installed over any Monogram electric or gas cooktop. It cannot be installed over a Monogram 3URIHVVLRQDOFRRNWRSRUUDQJH 3 Installation Preparation ADVANCE PLANNING POWER SUPPLY Ductwork Planning Ŷ7KHVHYHQWKRRGVDUHHTXLSSHGIRU´URXQG ductwork. IMPORTANT - (Please read carefully) Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG $33/,$1&(0867%(3523(5/<*5281'(' Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH )RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOG QRWH[FHHGIWHTXLYDOHQWOHQJWKIRUDQ\GXFW configurations. Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH outdoors. Ŷ8VHULJLGPHWDOGXFWZRUNRQO\ Ŷ,QVWDOODURRIFDSZLWKGDPSHUDWWKHH[WHULRU opening. Order the cap and any transitions needed in advance. Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS UHSODFHPHQW air system in accordance with local building code UHTXLUHPHQWV9LVLW*($SSOLDQFHVFRPIRUDYDLODEOH makeup air solutions. Ductwork Planning Ŷ7KHVHYHQWKRRGVDUHKHDY\$GHTXDWHVWUXFWXUDO support must be provided. The ceiling structure must be capable of supporting the weight of the hood and any inadvertent user contact loads DSSUR[LPDWHO\SRXQGV 7KHKRRGVXSSRUW IUDPHZLOOEHVXSSRUWHGE\[FURVVIUDPLQJ Ŷ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLVLQVWDOOHG before the cooktop or countertop below is installed. Accessory Duct Cover Ŷ$OOPRGHOVDUHVKLSSHGZLWKDGXFWFRYHUIRUFHLOLQJ KHLJKWVRI¶´WR¶ =;DFFHVVRU\ duct cover is available WRUHDFK 1" WR 1" ceiling heights. The accessory should be ordered with the hood and be on site before final framing and wall finishing. 4 WARNING )253(5621$/6$)(7<7+,6 AVERTISSEMENT 3285'(65$,6216 '(6e&85,7e&(7$33$5(,/'2,7Ç75( &255(&7(0(170,6¬/$7(55( Remove house fuse or open circuit breaker before beginning installation. 'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWK WKLVDSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRU prevailing local codes and ordinances. Electrical supply 7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+] DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW breaker or time delay fuse. Ŷ:LULQJPXVWEHZLUHZLWKJURXQG Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH proceeding. Ŷ5RXWHKRXVHZLULQJLQWKHFHLOLQJDVFORVHWRWKH LQVWDOODWLRQORFDWLRQDVSRVVLEOH$OORZDGGLWLRQDO OHQJWKIURPFHLOLQJMRLVWVWRUHDFKWKHMXQFWLRQER[ on the bottom of the hood support frame. Ŷ&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQ accordance with local codes. Grounding instructions The grounding conductor must be connected to DJURXQGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ equipment-grounding terminal or lead on the hood. WARNING The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. AVERTISSEMENT Le mauvais branchement du fil GHPLVHjODWHUUHSHXWFDXVHUXQFKRFpOHFWULTXH(Q FDVGHGRXWHFRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQ WHFKQLFLHQSRXUGpWHUPLQHUVLO¶DSSDUHLOHVWjODWHUUH 49-80329 Rev. 5 Installation Preparation DUCT FITTINGS This Hood Must Use an 8” Round Duct. It Can Transition to a 3-1/4” x 12” Duct. 8VHWKLVFKDUWWRFRPSXWHPD[LPXPSHUPLVVLEOHOHQJWKV for duct runs to outdoors. NOTE:'RQRWH[FHHGPD[LPXPSHUPLVVLEOHHTXLYDOHQW lengths! Maximum duct length: 100 foot for range hoods. Duct Piece Dimensions Equivalent Length* 5RXQG straight 1 ft. (per foot length) ´[´ straight 1 ft. (per foot length) HOERZ IW HOERZ IW ´[´ HOERZ 43 ft. ´[´ HOERZ 26 ft. ´[´ IODW elbow IW ´URXQGWR ´[´ transition 2 ft. ´[´ WR´URXQG transition 5 ft. Quantity Used Total Equivalent Length Flexible ducting ,IIOH[LEOHPHWDOGXFWLQJLVXVHGDOOWKHHTXLYDOHQWIHHW YDOXHVLQWKHWDEOHVKRXOGEHGRXEOHG7KHIOH[LEOHPHWDO GXFWVKRXOGEHVWUDLJKWDQGVPRRWKDQGH[WHQGHGDV much as possible. DO NOTXVHIOH[LEOHSODVWLFGXFWLQJ NOTE: $Q\KRPHYHQWLODWLRQV\VWHPVXFKDVD YHQWLODWLRQKRRGPD\LQWHUUXSWWKHSURSHUIORZRI FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHGE\ILUHSODFHVJDV IXUQDFHVJDVZDWHUKHDWHUVDQGRWKHUQDWXUDOO\YHQWHG systems. To minimize the chance of interruption of such QDWXUDOO\YHQWHGV\VWHPVIROORZWKHKHDWLQJHTXLSPHQW manufacturer’s guidelines and safety standards such DVWKRVHSXEOLVKHGE\1)3$DQG$6+5$(:KHQ DSSOLFDEOHLQVWDOODQ\PDNHXS UHSODFHPHQW DLUV\VWHP in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. ´URXQGWR 6 ft. ´[´ WUDQVLWLRQ elbow ´[´ 13 ft. WR´URXQG WUDQVLWLRQ elbow Round wall cap with damper 32 ft. ´[´ wall cap with damper IW Round roof cap 44 ft. Total Duct Run $ FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJ equivalent. Equivalent length of duct pieces DUHEDVHGRQDFWXDOWHVWVFRQGXFWHGE\*( $SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFW requirements for good venting performance with any ventilation hood. 49-80329 Rev. 5 5 Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) 3/8" swivel socket or pivoting KH[VRFNHWZLWK H[WHQVLRQV Duct tape :LUHFXWWHUVWULSSHU Hammer Key hole saw Electric or battery-operated drill DQGELWV3KLOOLSVDQGIODW blade screwdriver bits. 3HQFLODQGWDSHPHDVXUH Safety glasses Spirit level 8" round metal GXFWOHQJWKWR suit installation. :LUHQXWV )ODVKOLJKW Saber saw or sawsall Step ladder 3KLOOLSVDQG flat blade screwdrivers Strain relief for junction cover. 9+]RU$PS 2-wire with ground. properly grounded branch circuit. Carpenter’s square 3OLHUV Metal snips REMOVE THE PACKAGING CAUTION /,)77+(+22'2872)7+(%2; %<7+(&(17(50(7$/3257,21'2127/,)7%< 7+(*/$666,'(6 ATTENTION /(9(=/$+277(¬/¶(;7e5,(85 '(/$%2Ì7(3$5/$3257,210e7$/&(175$/ 1(/(9(=3$63$5/(6&Ð7e6'(9(55( CAUTION :HDUJORYHVWRSURWHFWDJDLQVW sharp edges. ATTENTION 3RUWH]GHVJDQWVSRXUpYLWHUOHV EOHVVXUHVFDXVpHVSDUOHVWUDQFKDQWV 6 Ŷ*UDVSWKHKRRGE\WKHPHWDOLQVHUWLQWKHFHQWHUDQG OLIWVWUDLJKWXSDQGRXWRIWKHER[ Ŷ5HPRYHDQGSURSHUO\GLVFDUGWKHSODVWLFZUDSSLQJ Ŷ5HPRYHSDUWVER[GXFWFRYHUVDQGRWKHUSDFNDJLQJ 49-80329 Rev. 5 Installation Preparation Ceiling Height Mounting Frame Height (inches) Trim Needed Ŷ'HFRUDWLYHGXFWFRYHUVDUHSURYLGHGWRFRQFHDOWKH ductwork running to the ceiling. Possible Hood Installation Height (inches) 26 $ Ŷ7KLVKRRGFDQEHLQVWDOOHGIRUUHFLUFXODWLQJ RSHUDWLRQ1RNLWVUHTXLUHG 8’ $ 24 34 1/2 B 7KHKRRGLQVWDOODWLRQKHLJKWIURPWKHFRRNLQJVXUIDFH WRWKHERWWRPRIWKHKRRGGHSHQGVXSRQFHLOLQJ height. 28 $ 25 34 1/2 B $ )RURSWLPXPSHUIRUPDQFHWKHKRRGPXVWEH´PLQ DQG´PD[DERYHWKHFRRNLQJVXUIDFH 3" 26 34 1/2 B $ Use the chart on this page to accurately determine LQVWDOODWLRQKHLJKWDQGVXSSRUWIUDPHDGMXVWPHQWDQG WRVHOHFWWKHFRUUHFWVL]HWRSWULPSLHFH $%&RU' 34 1/2 B 24 38 1/2 C 28 34 1/2 B 25 38 1/2 C 34 1/2 B 26 38 1/2 C 34 1/2 B 38 1/2 C 24 42 1/2 D DETERMINE INSTALLATION HEIGHT D C B $ =;$FFHVVRU\'XFWFRYHULQFOXGHVD´ long duct cover and 3 sets of duct cover top trim SLHFHVODEHOHG()* 28 38 1/2 C 25 42 1/2 D 38 1/2 C 26 42 1/2 D 38 1/2 C 42 1/2 D ZX92510 Accessory Duct Cover 49-80329 Rev. 5 24 46 1/2 E 28 42 1/2 D 25 46 1/2 E 42 1/2 D 26 46 1/2 E 3" 42 1/2 D 46 1/2 E 24 ) 28 46 1/2 E 25 ) 46 1/2 E 26 ) 46 1/2 E ) 24 54 1/2 * 28 ) 25 54 1/2 * ) 26 54 1/2 * ) 54 1/2 * 28 54 1/2 * Installation Preparation PARTS PROVIDED Locate the parts packed with the hood. Stainless steel filter $LUGHIOHFWRUIRU recirculating installation 1 charcoal filter for recirculating installation HARDWARE PACKAGE Locate and check contents. Screws shown actual size. 6 ceiling mounting screws 12 sheet metal screws Telescoping support frame Upper duct cover trim pieces 2 each of 4 sizes 12 cage nuts VFUHZVWRWDO • 24 support frame screws KRRGDWWDFKPHQW screws • 2 upper duct cover attachment screws • 4 recirculating deflector screws • 2 duct cover bracket 2 Duct cover attachment screws brackets 2 thumb screws Lower duct cover trim pieces Note: Some additional hardware/screws included. Drill 3/16≤ Pilot Holes Approx. 1-1/2≤ Deep Cut a 1≤ Dia. Wire Access Hole 10-1/16≤ to Centerline of Holes Drill 3/16≤ Pilot Holes Approx. 1-1/2≤ Deep 7-1/16≤ to Centerline of Holes 24-3/4" 23-1/4" 81/2 ≤ 49-80406 Printed in Italy D ia . 04-06 JR 36≤ Hood Template Cut a 1≤ Dia. Wire Access Hole 7-1/16≤ to Centerline of Holes FRONT OF HOOD Template 8 Decorative duct covers (14"ZLGHGHHSZKHQDVVHPEOHG 49-80329 Rev. 5 Installation Preparation CONSTRUCT CEILING SUPPORT Plan the Location of the Hood and Ductwork ŶUse a plumb bob to check the location. The countertop/cooktop below the hood must be centered with the hood. Ceiling Hood ducting centerline Ŷ7KHKRRGVKRXOGH[WHQGEH\RQGWKHIURQW and rear edge of the cooking appliance. ŶThe duct in the ceiling must be centered over the cooktop. )URQW 13-3/4" Cooktop $OLJQZLWKFHQWHU of cooktop Countertop Side view Ceiling Support Structure Ŷ$WWKHKRRGORFDWLRQLQVWDOO[FURVVIUDPLQJ Ŷ$UUDQJHFURVVIUDPLQJLQWKHFHLOLQJWRVXLWWKHH[LVWLQJ EHWZHHQFHLOLQJMRLVWVDVVKRZQ [¶VDUHUHTXLUHGWR structure. support the weight of the hood.) Ŷ<RXUFHLOLQJMRLVWVZLOOEHOLNHRQHRIWKHIROORZLQJ H[DPSOHV Install cross-framing symmetrically over duct/ cooktop centerline (;$03/($ 16" joist spacing ´GXFW [FURVV framing )URQW of hood $OLJQGXFWWR center of cooktop Cooktop outline Top view – ceiling joists parallel to front of hood 49-80329 Rev. 5 Installation Preparation CONSTRUCT CEILING SUPPORT (Cont.) (;$03/(% 16" joist spacing LQVWDOO cross-framing symmetrically over duct/cooktop centerline [FURVV framing 8" duct )URQW of hood Cooktop outline $OLJQGXFW to center of cooktop Top view – ceiling joists run perpendicular to front of hood (;$03/(& LQVWDOOFURVV framing symmetrically over duct/cooktop centerline [FURVV framing 8" duct 16" joist spacing )URQW of hood $OLJQGXFW to center of cooktop Cooktop outline Top view – ceiling joists at angle to front of hood 49-80329 Rev. 5 Installation Preparation CONSTRUCT CEILING SUPPORT (Cont.( Ŷ6HFXUHHDFK[EORFNZLWKDWOHDVWIRXU ZRRGVFUHZV´ORQJ QRWVXSSOLHG 8VHZRRG screws total for the two supports. 2x 4 Min. Cross Framing [PLQFURVVIUDPLQJ ŶThe cross framing must be accurately aligned to assure correct positioning of the hood. ŶThe cross framing must be level in all directions. Check with a spirit level and adjust if necessary. IMPORTANT: The ceiling structure must be capable of VXSSRUWLQJWKHZHLJKWRIWKHKRRG DSSUR[LPDWHO\ pounds) and any inadvertent user contact loads. The KRRGVXSSRUWIUDPHZLOOEHVXSSRUWHGE\WKH[FURVV framing. Ceiling Ceiling joist Joist 7-1/16" 10-3/4 Height Height adjustment Adjustment screws Screw Holes Ductwork for Installations Vented to the Outdoors Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH )RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRW H[FHHGIHHWHTXLYDOHQWOHQJWKIRUDQ\GXFW configuration. Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH outdoors. Ŷ7KLVYHQWKRRGPXVWXVH´URXQGULJLGGXFW Ŷ,QVWDOOWKHKRXVHGXFWZRUNWRUXQKRUL]RQWDOO\EHWZHHQ ceiling joists or straight up through the roof. CeilingJoint joist Ceiling 8" Duct 10" Duct [ 2x4 Vent Vent straight up through Straight Up the ceiling Through The Ceiling Finish the Ceiling Ŷ)LQLVKWKHFHLOLQJVXUIDFH%HVXUHWRPDUNORFDWLRQRI the ceiling joists and cross framing. Check to be sure the ceiling is level; use shims if necessary. 49-80329 Rev. 5 11 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 1 MOUNT TEMPLATE Drill 3/16≤ Pilot Holes Approx. 1-1/2≤ Deep Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG tape in place. Cut a 1≤ Dia. Wire Access Hole 10-1/16≤ to Centerline of Holes Drill 3/16≤ Pilot Holes Approx. 1-1/2≤ Deep 7-1/16≤ to Centerline of Holes – Be sure the template is oriented correctly with the front of the hood. ia 81/2 ≤ 49-80406 Printed in Italy D Ŷ8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHV will provide parallel alignment with the countertop below. . 04-06 JR 36≤ Hood Template Cut a 1≤ Dia. Wire Access Hole 7-1/16≤ to Centerline of Holes FRONT OF HOOD Ŷ&HQWHUSXQFKDOOKROHORFDWLRQV Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´ ELWDQGGULOODSSUR[LPDWHO\´GHHS Ŷ'ULYHKH[KHDGZRRGVFUHZVLQWRWKHFHQWHURIWKH FHLOLQJMRLVWVDQGFURVVIUDPLQJ/HDYHD´JDSWR allow the screw head to engage the keyhole slots on the support frames. Ŷ&XWWKH´GXFWRSHQLQJWKURXJKWKHVKHHWURFN 1/4" Gap 2 ADJUST FRAME HEIGHT Ŷ0HDVXUHH[DFWFHLOLQJKHLJKW Ŷ)LQGWKHH[DFWIUDPHKHLJKWUHTXLUHG RQWKHFKDUWRQSDJH Ŷ5HPRYHVFUHZVRQHDFKRIWKH sides of the frame to loosen the upper VWUXFWXUHORZHUVWUXFWXUHDQGEORZHU motor. Ŷ$GMXVWWKHKHLJKW³;´DFFRUGLQJWR WKHFKDUWRQSDJH8VHDWRWDORI 32 screws (8 screws on each side) WRVHFXUHWKHXSSHUVWUXFWXUHORZHU structure and blower/motor together. 12 )UDPH height 2-3/4" 24"min. PD[ Ceiling height X 36"min. 49-80329 Rev. 5 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 3 CUT DUCT TO LENGTH FOR 5 INSTALL HOOD ATTACHMENT SCREWS VENTED Ŷ0HDVXUHIURPKRXVH GXFWWRH[KDXVW opening. House duct Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ screw head and support flange. Ŷ&XWWKH´GXFWOHQJWK to size. Ŷ6OLSGXFWRYHUWKH H[KDXVWRSHQLQJ Ŷ6HDOWKHFRQQHFWLRQ with duct tape. Duct Duct length )UDPH height Install 4 attachment screws 4 INSTALL THE SUPPORT FRAME Ŷ5DLVHWKHVXSSRUWWRZDUG the ceiling. Ŷ7KUHDGWKHKRXVHZLULQJ through one of the large KROHVSUHIHUDEO\RQWKHOHIW side. Duct Ŷ&DUHIXOO\HQJDJHWKH ceiling mounting screws to WKHNH\KROHVORWV$1'WKH house duct in the top of the frame. Ŷ7LJKWHQWKHPRXQWLQJ screws against the frame. Ŷ,QVWDOOVDIHW\VFUHZV Ŷ8VHGXFWWDSHWRVHDOWKH duct connection at the top. Safety screws Keyhole slots House wiring 49-80329 Rev. 5 Keyhole slots 13 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 6 MOUNT THE HOOD ONTO THE SUPPORT WARNING 2 people are required to lift and 7 CONNECT CABLES Ŷ-RLQWKHWZRFDEOHFRQQHFWRUVDWWKHIURQWRIWKH hood. Secure the cables behind the retainer clip. position the hood onto the mounting bracket. AVERTISSEMENT ,IIDXWGHX[SHUVRQQHVSRXU lever et mettre en place la hotte sur le support de montage. Retainer clip To lights To control panel Ŷ/LIWWKHKRRGWRWKHERWWRPRIWKHVXSSRUWHQJDJLQJ the keyhole slots to the 4 mounting screws. Ŷ7LJKWHQWKHPRXQWLQJVFUHZV Ŷ,QVWDOODGGLWLRQDOVFUHZVDVVKRZQ Install 6 screws 14 49-80329 Rev. 5 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 8 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING If house wiring is not 2-wire with a JURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKHLQVWDOOHU :KHQKRXVHZLULQJLVDOXPLQXPEHVXUHWRXVH8/ DSSURYHGDQWLR[LGDQWFRPSRXQGDQGDOXPLQXPWR copper connectors. AVERTISSEMENT Si le câblage de la maison n’est SDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUHO¶LQVWDOODWHXU GRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHVILOVGHOD PDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQG¶XWLOLVHUGHOD SkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HWGHVFRQQHFWHXUV pour l’aluminium-cuivre. Ŷ6HFXUHWKHKRXVHZLULQJWRWKHMXQFWLRQER[ZLWK a strain relief. Ŷ House wiring -%R[FRYHU Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXWRQWKH left side. Knockout -%R[FRYHU Connect white leads to branch circuit white lead. Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ lead or bare ground lead. Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK electrical connector. Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU Be sure wires are not pinched. Ŷ6HFXUH-%R[FRYHUZLWKRULJLQDOVFUHZ 49-80329 Rev. 5 15 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 9 PREPARE THE DUCT COVERS Ŷ5HPRYHWKHSODVWLFSURWHFWLYHFRYHULQJRQDOOGXFW pieces. Ŷ,QVWDOOFDJHQXWVRQHDFKLQVLGHVHFWLRQRIWKHWRS duct cover. The cage nuts fit into the rectangular VORWVFOLSVIDFLQJRXWZDUG Ŷ,QVWDOOFDJHQXWVRQHDFKVLGHRIWKHORZHUGXFW covers. 10 INSTALL UPPER DUCT COVER Ŷ3ODFHWKHWDOOGXFWFRYHUVRQWRWKHWRSRIWKHKRRG This section has venting holes on one end. NOTE: If you are installing this hood for UHFLUFXODWLQJRSHUDWLRQSODFHWKHGXFWFRYHUVRQWR the hood with the venting slots at the top. ,IWKHKRRGLVYHQWHGWRWKHRXWVLGHWKHKROHV should be positioned on the bottom. Rectangular slots 1XW 3ODQ diagram Top sections Top sections Ŷ6HFXUHWKHVLGHVZLWKVFUHZVLQVWDOOHGWKURXJKWKH cage nuts. Support frame 16 Ŷ5DLVHWKHDVVHPEOHGGXFWFRYHUVWRWKHWRSDJDLQVW the ceiling. Ŷ0DWFKPRXQWLQJKROHVRQHRQHDFKVLGH,QVWDOO screws through the duct and into the support. 49-80329 Rev. 5 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 11 INSTALL LOWER DUCT )URQWERWWRPGXFWFRYHUVHFWLRQ (snap into place and secure with 6 screws – 3 per side) 12 INSTALL DUCT COVER TRIM Upper trim strip Upper trim strip Side bracket 3ODQGLDJUDPWRS view Lower trim strip Lower trim strip )URQWERWWRPGXFW cover sections Ŷ,QVWDOOVLGHEUDFNHWVWRVHFXUHWKHORZHUGXFWWLJKWO\ against the upper duct. Ŷ+ROGORZHUWULPVWULSV QDUURZSLHFHV ZLWKKRRNV IDFLQJGRZQ3ODFHWKHKRRNVLQVLGHWKHVORWVDQG slide downward. Ŷ6HOHFWWKHFRUUHFWVL]HXSSHUWULPVWULSVDQGSUHVV into place. 13 INSTALL METAL FILTER IMPORTANT:&KHFNWREHVXUHWKDWWKHPDLQ21 2))VZLWFKQH[WWRWKHPRWRULVLQWKH21SRVLWLRQ )LOWHUORFN Ŷ3ODFHUHDUGXFWFRYHURQWRWKHKRRG Ŷ3ODFHIURQWGXFWFRYHURQWRWKHKRRG Ŷ6HFXUHWKHGXFWFRYHUVZLWKVFUHZV Ŷ7LSWKHILOWHULQWRWKHOHIWRUULJKWVLGHRIWKHRSHQLQJ Lift the filter to the opposite side and into the filter lock. Ŷ7RUHPRYHWKHILOWHUSXOOWKHILOWHUORFNGRZQZDUG 14 FINALIZE INSTALLATION Ŷ5HPRYHDOOWDSHDQGSDFNLQJPDWHULDO Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ instructions. 49-80329 Rev. 5 Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 1 MOUNT TEMPLATE Drill 3/16≤ Pilot Holes Approx. 1-1/2≤ Deep Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG tape in place. Cut a 1≤ Dia. Wire Access Hole 10-1/16≤ to Centerline of Holes Drill 3/16≤ Pilot Holes Approx. 1-1/2≤ Deep 7-1/16≤ to Centerline of Holes – Be sure the template is oriented correctly with the front of the hood. ia 81/2 ≤ 49-80406 Printed in Italy D Ŷ8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHV will provide parallel alignment with the countertop below. . 04-06 JR 36≤ Hood Template Cut a 1≤ Dia. Wire Access Hole 7-1/16≤ to Centerline of Holes FRONT OF HOOD Ŷ&HQWHUSXQFKDOOKROHORFDWLRQV Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´ ELWDQGGULOODSSUR[LPDWHO\´GHHS Ŷ'ULYHKH[KHDGZRRGVFUHZVLQWRWKHFHQWHURIWKH FHLOLQJMRLVWVDQGFURVVIUDPLQJ/HDYHD´JDSWR allow the screw head to engage the keyhole slots on the support frames. Ŷ&XWWKH´GXFWRSHQLQJWKURXJKWKHVKHHWURFN 1/4" Gap 2 ADJUST FRAME HEIGHT Ŷ0HDVXUHH[DFWFHLOLQJKHLJKW Ŷ)LQGWKHH[DFWIUDPHKHLJKWUHTXLUHG RQWKHFKDUWRQSDJH Ŷ5HPRYHVFUHZVRQHDFKRIWKH sides of the frame to loosen the upper VWUXFWXUHORZHUVWUXFWXUHDQGEORZHU motor. Ŷ$GMXVWWKHKHLJKW³;´DFFRUGLQJWR WKHFKDUWRQSDJH8VHDWRWDORI 32 screws (8 screws on each side) WRVHFXUHWKHXSSHUVWUXFWXUHORZHU structure and blower/motor together. )UDPH height 2-3/4" 24"min. PD[ Ceiling height Mark each piece to indicate where screw holes align. X 36"min. NOTE: Low ceilings may require that the lower portion of the support frame be removed. The upper support frame may be secured directly to the blower/motor. Refer to the FKDUWRQSDJHIRU\RXUFHLOLQJKHLJKWDQG to be sure the duct cover trim piece will fit. 18 49-80329 Rev. 5 Installation Instructions INSTALLATION—RECIRCULATING 3 INSTALL AIR DEFLECTOR, CUT DUCT FOR RECIRCULATING OPERATION Ŷ7HPSRUDULO\VOLGHWKHDLUGHIOHFWRU into the support frame. 4 INSTALL UPPER SUPPORT FRAME Ŷ5DLVHWKHXSSHUVXSSRUW toward the ceiling. Ŷ7KUHDGWKHKRXVHZLULQJ through one of the large KROHVSUHIHUDEO\RQWKHOHIW side. Ŷ&DUHIXOO\HQJDJHWKHFHLOLQJ mounting screws to the keyhole slots in the top of the frame. Safety screws )5217 Keyhole slots Ŷ0HDVXUHGXFWOHQJWKEHWZHHQ the deflector and over the H[KDXVWRSHQLQJ Ŷ&XWGXFWSLHFHWROHQJWKDQG set aside. Duct length House wiring Keyhole slots Ŷ7LJKWHQWKHPRXQWLQJVFUHZVDJDLQVWWKHIUDPH Ŷ,QVWDOOVDIHW\VFUHZV )5217 Ŷ6OLGHDLUGHIOHFWRU into the support frame. Ŷ6HFXUHWKHGHIOHFWRU to the support with 4 screws. Ŷ,QVWDOOWKHGXFW piece to the bottom of the deflector and seal the connection with duct tape. 49-80329 Rev. 5 Installation Instructions INSTALLATION—RECIRCULATING 5 INSTALL LOWER STRUCTURE TO UPPER STRUCTURE Ŷ6OLGHORZHUIUDPHLQWRWKH upper frame. Match the marked alignment holes. 7 INSTALL HOOD ATTACHMENT SCREWS Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ screw head and support flange. Ŷ6HFXUHWKHXSSHUDQGORZHU IUDPHZLWKVFUHZVRQ each side of the frame. Install 4 attachment screws 6 INSTALL BLOWER/MOTOR Ŷ5DLVHWKHEORZHU motor piece toward the assembled frame. Ŷ&DUHIXOO\UDLVHWKHPRWRUWR the marked reference point while making sure the duct piece slips over the blower outlet flange. 8 MOUNT THE HOOD ONTO THE SUPPORT WARNING 2 people are required to lift and position the hood onto the mounting bracket. AVERTISSEMENT Ŷ6HFXUHWKHEORZHUPRWRUWR WKHIUDPHXVLQJVFUHZV 4 on each side. ,IIDXWGHX[SHUVRQQHVSRXU lever et mettre en place la hotte sur le support de montage. Ŷ8VHWDSHWRVHDOWKHGXFW connection. Ŷ/LIWWKHKRRGWRWKHERWWRP RIWKHVXSSRUWHQJDJLQJ the keyhole slots to the 4 mounting screws. Ŷ7LJKWHQWKHPRXQWLQJ screws. Ŷ,QVWDOO additional screws as shown. Install 6 screws 49-80329 Rev. 5 Installation Instructions INSTALLATION—RECIRCULATING 9 CONNECT CABLES Ŷ-RLQWKHWZRFDEOHFRQQHFWRUVDWWKHIURQWRIWKHKRRG Secure the cables behind the retainer clip. Retainer clip To lights To control panel 10 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING If house wiring is not 2-wire with a Ŷ6HFXUHWKHKRXVHZLULQJWRWKHMXQFWLRQER[ZLWKD strain relief. House wiring JURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKHLQVWDOOHU :KHQKRXVHZLULQJLVDOXPLQXPEHVXUHWRXVH8/ DSSURYHGDQWLR[LGDQWFRPSRXQGDQGDOXPLQXPWR copper connectors. AVERTISSEMENT Si le câblage de la maison n’est SDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUHO¶LQVWDOODWHXU GRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHVILOVGHOD PDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQG¶XWLOLVHUGHOD SkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HWGHVFRQQHFWHXUV pour l’aluminium-cuivre. -%R[FRYHU Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXWRQWKH left side. Knockout -%R[FRYHU Ŷ&RQQHFWZKLWHOHDGVWREUDQFKFLUFXLWZKLWHOHDG Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ lead or bare ground lead. Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK electrical connector. Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%H sure wires are not pinched. Ŷ6HFXUH-%R[FRYHUZLWKRULJLQDOVFUHZ 49-80329 Rev. 5 21 Installation Instructions INSTALLATION—RECIRCULATING 11 PREPARE THE DUCT COVERS Ŷ5HPRYH the plastic protective covering on all duct pieces. Ŷ,QVWDOO cage nuts on each inside section of the top duct cover. The cage nuts fit into the rectangular VORWVFOLSV facing outward. 13 INSTALL LOWER DUCT COVER )URQWERWWRPGXFWFRYHUVHFWLRQ (snap into place and secure with 6 screws – 3 per side) Rectangular slots 1XW 3ODQ diagram top view 3ODQ diagram Top sections Ŷ,QVWDOOFDJH nuts on each side of the lower duct covers. Top sections )URQWERWWRPGXFW cover sections Support frame 12 INSTALL UPPER DUCT COVER Ŷ3ODFHWKHWDOOGXFW covers onto the top of the hood. This section has venting holes on one end. NOTE: If you are installing this hood for recirculating RSHUDWLRQSODFHWKH duct covers onto the hood with the venting slots at the top. Ŷ3ODFHUHDUGXFWFRYHURQWRWKHKRRG Ŷ3ODFHIURQWGXFWFRYHURQWRWKHKRRG Ŷ6HFXUHWKHGXFWFRYHUVZLWKVFUHZV ,IWKHKRRGLVYHQWHGWRWKHRXWVLGHWKHKROHV should be positioned on the bottom. Ŷ6HFXUHWKHVLGHVZLWKVFUHZVLQVWDOOHGWKURXJKWKH cage nuts. Ŷ5DLVHWKHDVVHPEOHGGXFWFRYHUVWRWKHWRSDJDLQVW the ceiling. Ŷ0DWFKPRXQWLQJKROHVRQHRQHDFKVLGH,QVWDOO screws through the duct and into the support. 22 49-80329 Rev. 5 Installation Instructions INSTALLATION—RECIRCULATING 14 INSTALL DUCT COVER TRIM Side bracket Upper trim strip Lower trim strip Upper trim strip 15 INSTALL FILTERS IMPORTANT: &KHFNWREHVXUHWKDWWKHPDLQ21 2))VZLWFKQH[WWRWKHPRWRULVLQWKH21SRVLWLRQ Lower trim strip Charcoal filter Ŷ,QVWDOOWKHEODFNFKDUFRDOILOWHULQWRWKHFHQWHU opening. Secure the filter with thumbscrews on each side. )LOWHUORFN Ŷ,QVWDOOVLGHEUDFNHWVWRVHFXUHWKHORZHUGXFWWLJKWO\ against the upper duct. Ŷ+ROGORZHUWULPVWULSV QDUURZSLHFHV ZLWKKRRNV IDFLQJGRZQ3ODFHWKHKRRNVLQVLGHWKHVORWVDQG slide downward. Ŷ6HOHFWWKHFRUUHFWVL]HXSSHUWULPVWULSVDQGSUHVV into place. Metal filter Ŷ7LSWKHILOWHULQWRWKHOHIWRUULJKWVLGHRIWKH opening. Lift the filter to the opposite side and into the filter lock. Ŷ7RUHPRYHWKHILOWHUSXOOWKHILOWHUORFNGRZQZDUG 16 FINALIZE INSTALLATION Ŷ5HPRYHDOOWDSHDQGSDFNLQJPDWHULDO Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ instructions. 49-80329 Rev. 5 23 NOTE::KLOHSHUIRUPLQJLQVWDOODWLRQVGHVFULEHGLQWKLVERRN safety glasses or goggles should be worn. )RU0RQRJUDP®ORFDOVHUYLFHLQ\RXUDUHDYLVLW monogram.com. NOTE:3URGXFWLPSURYHPHQWLVDFRQWLQXLQJHQGHDYRUDW 0RQRJUDP$SSOLDQFHV7KHUHIRUHPDWHULDOVDSSHDUDQFH and specifications are subject to change without notice. 49-80329 Rev. 5 10-19 GEA Printed in Mexico ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement