Amperes ZS5602 is a 6-channel uninterrupted paging speaker zone selector designed for installations where paging to certain zones should not interrupt other zones in BGM mode. It features front panel zone switches for BGM and paging, an all-call paging switch, and a remote select port for zone selection during paging. The unit also provides 24V DC outputs for overriding volume controllers and emergency paging. With its reliable performance and flexible connectivity options, the ZS5602 is an ideal choice for various paging and background music applications.
advertisement
INSTRUCTION MANUAL
ZS5602
6 Channel Uninterrupted Paging
Speaker Zone Selector
Thank you
for choosing another quality product from Amperes Electronics.
ZS5602 is used for uninterrupted paging installation, in which paging to certain zones shall not interrupt other zones that is in BGM mode.
Being a very matured product, ZS5602 has been used widely and accepted as a reliable and trustworthy component in any installation. Continuous product improvement policy by Amperes which means constant product upgrade had made it a worthwhile item with reasonable cost to invest in.
Please read through the manual to avoid unnecessary mistakes during installation and we assure that you are getting the product of your choice .. simply essential and truly reliable.
VER 4 / 2015
Parts Identification
Front View
1 2 3
Rear View
4 5 6 7 8 9
1. BGM FRONT PANEL ZONE SWITCH
These switches are for selecting zones for BGM broadcasting. Selection of BGM zones can only be made at these switches and not from remote control panel.
2. PAGING FRONT PANEL ZONE SWITCH
To page, use these switches and once pressed, it shall override the corresponding BGM zones to allow paging to be broadcasted. A 24V DC signal of the zone would be sent out from the DC output port at the rear panel. Be sure to turn these zones off at the front panel if a remote mic with zone selection is installed in the system.
3. ALL CALL PAGING SWITCH
Pressing ALL CALL switch shall activate all zones into paging mode, thus overriding all BGM broadcast. 24V DC shall present at all zones for emergency overriding purpose.
4. DC POWER INPUT
This equipment operates using 24V DC supply with 1A rating. Should external overriding of volume controllers is required, we suggest that a larger rating of supply is used, such as Amperes PS9400.
5. EMERGENCY OVERRIDE RELAY CONTACT
This port shall be connected to EP1200A Emergency Paging Panel. Once activated, all zones shall be in Paging mode and a dry contact is closed to enable connections for 24V DC supply to volume controllers for overriding purpose.
If this port is utilised, we recommend that the 24V zone DC outputs port to be ignored.
6. REMOTE SELECT PORT
This can be directly connected to TD6240 decoder or PM1000 series paging mic for remote zone selection during paging.
PAGE 2 ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR
Parts Identification
7. PAGING AMP INPUTS / ZONE OUTPUTS
Paging amplifier outputs are connected to these ports. In a 4 wire system, outputs to zones also comes from these connectors.
Please refer to “Connecting the Unit - 3 Wire System” and “Connecting the Unit - 4 Wire System” for correct set of termination.
8. ZONE 24V DC OUTPUT
24V DC shall present when a zone is pressed for paging. This shall enable 24V to override a volume controller. Alternatively, it can also be used for other purpose, such as indicator in a mimic panel, notifying that paging to a particular zone is in progress.
Note:
We suggest that this is not used in a normal system to avoid unnecessary interruption to sensitive zones during paging. Only override the volume controllers when truly necessary such as during emergency. Use EP1200A and link to
ZS5602 instead.
9. BGM AMP INPUTS / 3 WIRE SYSTEM OUTPUTS
Connect BGM set of amplifier outputs to these ports.
In 4 wire system, no zone outputs shall be connected from here. The outputs shall only be used for 3 wire installations. Please refer to “Connecting The Unit - 3 Wire System”
ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR PAGE 3
Connecting The Unit - 4 Wire System
FIRE
EP1200A EMERGENCY
PAGING MIC
E/M
Trigger
Overriding
-ve
Zone Outputs ( 4 wire system )
OFF
SPEAKER VOLUME
OVERRIDE
OFF
SPEAKER VOLUME
OVERRIDE
OFF
SPEAKER VOLUME
OVERRIDE
OFF
SPEAKER VOLUME
OVERRIDE
OFF
SPEAKER VOLUME
OVERRIDE
OFF
SPEAKER VOLUME
OVERRIDE
Volume Controllers
ZS5602 UNINTERRUPTED
ZONE SELECTOR
24V
DC
Cat5e Cable
( supplied )
6 zones triggering
From Paging Amplifiers
Single or multiple amplifiers
PM1060 / 1120
ANALOGUE MIC WITH
REMOTE TRIGGERING
Triggering ZS5602 can be made via PM1060 / 1120 paging mic or PD2400 / 2800 via TD6240. ( Refer to
Cascading the Unit ).
Pin connections of PM1060 / 1120 to ZS5602 :
PM1060 / 1120
Pin 1 to 6
Pin 7 to 12
Pin 13 ( -ve )
Pin 14 ( NC )
Pin 15 ( +ve )
ZS5602
Pin 1 to 6 ( Zone 1 to 6 ) to next unit Pin 1 to 6
Pin 7 ( +ve ) nil
Pin 8 ( -ve )
1 8
BGM Amplifiers
RJ45 Pin configurations.
Note that All Call and PR from remote mic shall not be required.
PAGE 4 ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR
Cascading The Units
ZS5602 can be cascaded if required in a large installation. There is no limitation on the number of units to be cascaded and no extra link cable is required.
TD6240
DECODER
ZS5602
Unit 1
(Zone 1 to 6)
ZS5602
Unit 2
(Zone 7 to 12)
Connections to EP and
Volume controllers for
E/M overriding
Unit 3
(Zone 13 to 18)
ZS5602
Unit 4
(Zone 19 to 24)
Connecting the Unit - 3 Wire System
ZS5602 is suitable for both 3 and 4 wire setup. If 3 wire system is required, a little modification to the unit is required, as illustrated below
1. Open the top casing
2. Cut the twin cables connecting the PCBs ( PCB 1 and PCB 2 )
3. Close the casing
Please make sure that the cut cable are properly insulated and do not let any loose copper strands visible that may be in contact with the metal casing.
PCB 1 PCB 2
CUT ALL THE TWIN CABLES
REAR SIDE
Cut only when it is intended to be used in 3 wire system
ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR PAGE 5
Connecting The Unit - 3 Wire System
FIRE
E/M
Trigger
EP1200A EMERGENCY
PAGING PANEL
To Speakers
3 wire
Volume
Controller
Paging
Output
OFF
SPEAKER VOLUME
OVERRIDE
OFF
SPEAKER VOLUME
OVERRIDE BGM output
ZS5602
ZONE SELECTOR
24V DC
Remote
Trigger Paging Amp
Join Commons for same zone only
PM1060 / 1120
PAGING MIC OR
PD2400 / 2800 VIA TD6240
BGM Amp
Note :
Join the COM connections for the same zone, ie
Zone 1 Paging COM to Zone 1 BGM com outputs.
Use only external volume controllers suitable for 3 wire system.
Proper cabling / termination works need to be observed in 3 wire installations. Failure to do so may cause audio crossing to adjacent zone, or slight leakage of sound through speaker though the volume controller is at off position.
To Zone Speakers
O FF
SPEAKER VOLUME
1
2 3
4
5
OVERRIDE
3 wire
Volume Controller
100V
Paging
Com 100V
BGM
PAGE 6 ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR
Schematic Diagram
CD PLAYER / OTHER MUSIC SOURCES
Note : required
PAGING MIC
Paging
AMPLIFIER FOR
PAGING zone triggering
BGM inputs
Mixed BGM only
MX2222 PRE-AMPLIFIER MIXER
AMPLIFIER FOR BGM
Paging
100V line
SPEAKERS
BGM
ZS5602 ZONE SELECTOR
100V line 24V DC overriding
VOLUME
CONTROLLER
Technical Data
Input voltage
Power consumption
Relay contacts
Zone load rating
DC output rating
Remote select
Amplifier inputs
Zone selections
Switching indicators
Cabling connections
Dimensions (W x H x D) mm
Weight
24V DC ; 0.5 A
10W ; 0.42 at ALL CALL ( without volume controllers connected )
Double pole ; 5A
500W 100V line
5A per zone
RJ45 - 6 zones
6 BGM and 6 Paging Amplifiers
6 zones via front panel / remote select
Front panel LED
Up to 2.5 mm via detachable connectors
482 x 44 x 180 mm
2.2 kg
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product improvements.
ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR PAGE 7
Warranty Conditions
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics
Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan
Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is not valid if repairs are performed by unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser. This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the product with power supply voltage other than shown on the product, or any other power supply source / adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the unit; moreover the warranty does not cover any damages which may be caused to people and things when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the date of purchase or for a longer period in countries where this is stated by a national law. In this case, the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the design changes or improvements are made.
Disclaimer
Information contained in this manual is subject to change without prior notice and does not represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN
BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.
ISO 9001: 2008
Design & Manufacture of Public Address Equipment and Systems
Certificate No. 16895 / A / 0001 / UK / En
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
Published : MAY 2015
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement