INSTRUCTION MANUAL

ZS5602

6 Channel Uninterrupted Paging

Speaker Zone Selector

Thank you

for choosing another quality product from Amperes Electronics.

ZS5602 is used for uninterrupted paging installation, in which paging to certain zones shall not interrupt other zones that is in BGM mode.

Being a very matured product, ZS5602 has been used widely and accepted as a reliable and trustworthy component in any installation. Continuous product improvement policy by Amperes which means constant product upgrade had made it a worthwhile item with reasonable cost to invest in.

Please read through the manual to avoid unnecessary mistakes during installation and we assure that you are getting the product of your choice .. simply essential and truly reliable.

VER 4 / 2015

Parts Identification

Front View

1 2 3

Rear View

4 5 6 7 8 9

1. BGM FRONT PANEL ZONE SWITCH

These switches are for selecting zones for BGM broadcasting. Selection of BGM zones can only be made at these switches and not from remote control panel.

2. PAGING FRONT PANEL ZONE SWITCH

To page, use these switches and once pressed, it shall override the corresponding BGM zones to allow paging to be broadcasted. A 24V DC signal of the zone would be sent out from the DC output port at the rear panel. Be sure to turn these zones off at the front panel if a remote mic with zone selection is installed in the system.

3. ALL CALL PAGING SWITCH

Pressing ALL CALL switch shall activate all zones into paging mode, thus overriding all BGM broadcast. 24V DC shall present at all zones for emergency overriding purpose.

4. DC POWER INPUT

This equipment operates using 24V DC supply with 1A rating. Should external overriding of volume controllers is required, we suggest that a larger rating of supply is used, such as Amperes PS9400.

5. EMERGENCY OVERRIDE RELAY CONTACT

This port shall be connected to EP1200A Emergency Paging Panel. Once activated, all zones shall be in Paging mode and a dry contact is closed to enable connections for 24V DC supply to volume controllers for overriding purpose.

If this port is utilised, we recommend that the 24V zone DC outputs port to be ignored.

6. REMOTE SELECT PORT

This can be directly connected to TD6240 decoder or PM1000 series paging mic for remote zone selection during paging.

PAGE 2 ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR

Parts Identification

7. PAGING AMP INPUTS / ZONE OUTPUTS

Paging amplifier outputs are connected to these ports. In a 4 wire system, outputs to zones also comes from these connectors.

Please refer to “Connecting the Unit - 3 Wire System” and “Connecting the Unit - 4 Wire System” for correct set of termination.

8. ZONE 24V DC OUTPUT

24V DC shall present when a zone is pressed for paging. This shall enable 24V to override a volume controller. Alternatively, it can also be used for other purpose, such as indicator in a mimic panel, notifying that paging to a particular zone is in progress.

Note:

We suggest that this is not used in a normal system to avoid unnecessary interruption to sensitive zones during paging. Only override the volume controllers when truly necessary such as during emergency. Use EP1200A and link to

ZS5602 instead.

9. BGM AMP INPUTS / 3 WIRE SYSTEM OUTPUTS

Connect BGM set of amplifier outputs to these ports.

In 4 wire system, no zone outputs shall be connected from here. The outputs shall only be used for 3 wire installations. Please refer to “Connecting The Unit - 3 Wire System”

ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR PAGE 3

Connecting The Unit - 4 Wire System

FIRE

EP1200A EMERGENCY

PAGING MIC

E/M

Trigger

Overriding

-ve

Zone Outputs ( 4 wire system )

OFF

SPEAKER VOLUME

OVERRIDE

OFF

SPEAKER VOLUME

OVERRIDE

OFF

SPEAKER VOLUME

OVERRIDE

OFF

SPEAKER VOLUME

OVERRIDE

OFF

SPEAKER VOLUME

OVERRIDE

OFF

SPEAKER VOLUME

OVERRIDE

Volume Controllers

ZS5602 UNINTERRUPTED

ZONE SELECTOR

24V

DC

Cat5e Cable

( supplied )

6 zones triggering

From Paging Amplifiers

Single or multiple amplifiers

PM1060 / 1120

ANALOGUE MIC WITH

REMOTE TRIGGERING

Triggering ZS5602 can be made via PM1060 / 1120 paging mic or PD2400 / 2800 via TD6240. ( Refer to

Cascading the Unit ).

Pin connections of PM1060 / 1120 to ZS5602 :

PM1060 / 1120

Pin 1 to 6

Pin 7 to 12

Pin 13 ( -ve )

Pin 14 ( NC )

Pin 15 ( +ve )

ZS5602

Pin 1 to 6 ( Zone 1 to 6 ) to next unit Pin 1 to 6

Pin 7 ( +ve ) nil

Pin 8 ( -ve )

1 8

BGM Amplifiers

RJ45 Pin configurations.

Note that All Call and PR from remote mic shall not be required.

PAGE 4 ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR

Cascading The Units

ZS5602 can be cascaded if required in a large installation. There is no limitation on the number of units to be cascaded and no extra link cable is required.

TD6240

DECODER

ZS5602

Unit 1

(Zone 1 to 6)

ZS5602

Unit 2

(Zone 7 to 12)

Connections to EP and

Volume controllers for

E/M overriding

Unit 3

(Zone 13 to 18)

ZS5602

Unit 4

(Zone 19 to 24)

Connecting the Unit - 3 Wire System

ZS5602 is suitable for both 3 and 4 wire setup. If 3 wire system is required, a little modification to the unit is required, as illustrated below

1. Open the top casing

2. Cut the twin cables connecting the PCBs ( PCB 1 and PCB 2 )

3. Close the casing

Please make sure that the cut cable are properly insulated and do not let any loose copper strands visible that may be in contact with the metal casing.

PCB 1 PCB 2

CUT ALL THE TWIN CABLES

REAR SIDE

Cut only when it is intended to be used in 3 wire system

ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR PAGE 5

Connecting The Unit - 3 Wire System

FIRE

E/M

Trigger

EP1200A EMERGENCY

PAGING PANEL

To Speakers

3 wire

Volume

Controller

Paging

Output

OFF

SPEAKER VOLUME

OVERRIDE

OFF

SPEAKER VOLUME

OVERRIDE BGM output

ZS5602

ZONE SELECTOR

24V DC

Remote

Trigger Paging Amp

Join Commons for same zone only

PM1060 / 1120

PAGING MIC OR

PD2400 / 2800 VIA TD6240

BGM Amp

Note :

Join the COM connections for the same zone, ie

Zone 1 Paging COM to Zone 1 BGM com outputs.

Use only external volume controllers suitable for 3 wire system.

Proper cabling / termination works need to be observed in 3 wire installations. Failure to do so may cause audio crossing to adjacent zone, or slight leakage of sound through speaker though the volume controller is at off position.

To Zone Speakers

O FF

SPEAKER VOLUME

1

2 3

4

5

OVERRIDE

3 wire

Volume Controller

100V

Paging

Com 100V

BGM

PAGE 6 ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR

Schematic Diagram

CD PLAYER / OTHER MUSIC SOURCES

Note : required

PAGING MIC

Paging

AMPLIFIER FOR

PAGING zone triggering

BGM inputs

Mixed BGM only

MX2222 PRE-AMPLIFIER MIXER

AMPLIFIER FOR BGM

Paging

100V line

SPEAKERS

BGM

ZS5602 ZONE SELECTOR

100V line 24V DC overriding

VOLUME

CONTROLLER

Technical Data

Input voltage

Power consumption

Relay contacts

Zone load rating

DC output rating

Remote select

Amplifier inputs

Zone selections

Switching indicators

Cabling connections

Dimensions (W x H x D) mm

Weight

24V DC ; 0.5 A

10W ; 0.42 at ALL CALL ( without volume controllers connected )

Double pole ; 5A

500W 100V line

5A per zone

RJ45 - 6 zones

6 BGM and 6 Paging Amplifiers

6 zones via front panel / remote select

Front panel LED

Up to 2.5 mm via detachable connectors

482 x 44 x 180 mm

2.2 kg

Note:

The above specifications are correct at time of printing but subjected to changes without prior notice due to product improvements.

ZS5602 | UNINTERRUPTED PAGING SPEAKER ZONE SELECTOR PAGE 7

Warranty Conditions

Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics

Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan

Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is not valid if repairs are performed by unauthorized personnel or service centres.

This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser. This warranty shall not extend to the replacement of the unit.

This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the product with power supply voltage other than shown on the product, or any other power supply source / adaptor not recommended by the manufacturer.

This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly related to the unit.

This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the unit; moreover the warranty does not cover any damages which may be caused to people and things when using the product.

This warranty certificate is valid only for the described product, and is not valid if modifications are made on this certificate or on the identification label applied on the product.

This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the date of purchase or for a longer period in countries where this is stated by a national law. In this case, the extension is valid only in the country where the product is purchased.

Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the design changes or improvements are made.

Disclaimer

Information contained in this manual is subject to change without prior notice and does not represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or damages whatsoever arising from the use of information or any error contained in this manual.

It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN

BHD or its authorized service agents.

AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction with this operating manual.

AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.

ISO 9001: 2008

Design & Manufacture of Public Address Equipment and Systems

Certificate No. 16895 / A / 0001 / UK / En

AMPERES ELECTRONICS SDN BHD

MADE IN MALAYSIA

Published : MAY 2015

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement