Heatstrip Design THD1500 Owner Manual

Add to My manuals
26 Pages

Heatstrip Design THD1500 is a premium high temperature heater and is primarily used for outdoor rooms where there is 1,2 3, or 4 enclosed sides, with an ideal mounting height of 2.1 m to 2.7m. It is also suitable for use in protected indoor applications. The stylish, slimline black face of the THD1500 does not emit light or glow when in use, blending elegantly into your décor. Ceiling, wall and umbrella mounting options ensure that your valuable floor and table space is not wasted.

advertisement

Heatstrip Design THD1500 Owner Manual | Manualzz

® Indoor

CONTENTS

Rev H Feb16

2

Product overview ___________________________ 3

Specifications ______________________________ 5

Spot heating principle ________________________ 6

Radiant footprint ____________________________ 7

Selection Guide _____________________________ 8

Table layout ________________________________ 9

Installation requirements ______________________ 10

Installation location __________________________ 11

Mounting options____________________________ 12

Standard mounting brackets ___________________ 13

Flush mount enclosure _______________________ 14

FME dimensions _________________________ 15

FME installation clearance dimensions _______ 16

FME installation instructions ________________ 17

Pole/beam mounting kit ______________________ 18

Twin mounting bracket _______________________ 19

End to end mounting bracket __________________ 20

Suspension mount bracket ____________________ 21

Extension mount bracket _____________________ 22

Wall controller w/ remote control ________________ 23

Wall control installation ____________________ 24

Safety, Maintenance _________________________ 25

Warranty __________________________________ 26

Dutch _____________________________________ 27

French ____________________________________ 53

German ___________________________________ 79

Product Overview

Why choose Heatstrip electric radiant heaters for your outdoor or hard-to-heat indoor area?

As there is typically constant air movement in an outdoor or open indoor area, many conventional patio heaters rely on convection heating which works by heating the surrounding air. This can be quite impractical for these areas, as this heated air can easily blow away with natural air movement. Radiant style heaters transfer heat directly to objects through infra-red waves.

Whilst convection heaters heat the air in between objects, radiant heaters heat the surface of the objects themselves.

HEATSTRIP electric radiant heaters are more effective within an outdoor or uninsulated indoor area because they provide targeted warmth directly to the people and objects in their path.

Discrete, stylish heating for undercover outdoor and indoor open areas

Using the radiant heating principle, HEATSTRIP can provide effective and energy efficient comfort heating for undercover outdoor and indoor open areas. HEATSTRIP has successfully enabled many entertainment venues such as restaurants, pubs and clubs to utilise their outdoor dining areas day and night, through all seasons. Within your workplace or business,

HEATSTRIP can provide comfort heating for designated outdoor smoking and leisure areas, as well as for workstation spot heating in factories, warehouses and showrooms. Within your home, HEATSTRIP can provide comfort heating for undercover alfresco dining and BBQ area, patios, verandas, courtyards and balconies.

Subtle, minimalist design

The stylish, slimline black face of the HEATSTRIP does not emit light or glow when in use, blending elegantly into your décor. Ceiling, wall and umbrella mounting options ensure that your valuable floor and table space is not wasted.

There are 3 different series of products within the Heatstrip product category. Each has a different temperature output, making them ideal for different applications. Below is a list of some common applications, to assist with the selection of the most effective and efficient series. This is a general guide only, please refer to the Product Manual for each product, for more information.

HEATSTRIP Max (THX models) is an ultra high temperature heater used for uncovered or open areas with a mounting height of 2.4 m to 3.5m.

HEATSTRIP Design (THH models) is a premium high temperature heater and is primarily used for outdoor rooms where there is 1,2 3, or 4 enclosed sides, with an ideal mounting height of 2.1 m to 2.7m.

HEATSTRIP Indoor (THS models) is a medium intensity heater used for protected indoor applications.

APPLICATION THX THH THS

Indoor insulated areas, classrooms, offices, bathrooms, wet areas, drying rooms X

Outdoor under cover, café, veranda, patio, balcony ceiling height 3m or less

Outdoor under cover, café, veranda, patio, balcony ceiling height 3m or more

Highly exposed outdoor area

Indoor open area, warehouse, factory, production areas, sports facilities

X

Indoor spot heating, above tables, assembly areas √

X

X

X

X

X

X

3

4

Efficient, cost effective electric heating

The innovative design of the HEATSTRIP enables comfortable and even heat dispersion from the surface with minimal operating costs.

Design flexibility

Three HEATSTRIP models are available, ensuring the heating requirements of any undercover outdoor or open indoor area is possible. Brackets for direct ceiling or wall/ceiling angled mounting are supplied as standard.

Optional HEATSTRIP accessories include beam or fixed umbrella mount brackets, extension mount brackets, chain suspension brackets, twin mount brackets and flush mounting enclosures.

Minimal maintenance

The HEATSTRIP incorporates no internal moving parts ensuring quiet and virtually maintenance free operation.

Australian made

Designed, engineered and assembled in

Australia the HEATSTRIP .

Stylish design— The Heater that is a Design Feature!

The attractive HEATSTRIP Design comes with a standard black face and anodised alloy rear casing.

Easy to use

The HEATSTRIP is controlled by a simple on/off operation, either when plugged directly into a power point, or hard-wired via a wall mounted on/off switch. The unit takes approximately 15 minutes to heat up to maximum temperature and approximately 30 minutes to cool down, depending upon the ambient temperature. Please don’t forget to turn it off.

Specifications - Europe

MODEL

THH1500AEU

POWER

(WATTS)

1500

THH2400AEU

THH3200AEU

THH1500AUK

THH2400AUK

THH3200A

HEATER TYPE

2400

3200

1500

2400

3200

OUTPUT

POWER

CONNECTION

APPROVALS

MOUNTING HEIGHT

MOUNTING OPTIONS

CURRENT

(AMPS)

5.9

12.3

12.5

6.1

9.8

PROTECTION RATING

COUNTRY OF MANUFACTURE

13.0

VOLTAGE

(VOLTS)

230

230

230

240

240

DIMENSIONS

(mm)

924 x 165 x 48

1364 x 165 x 48

WEIGHT

(Kg)

5

LEAD LENGTH

(mm)

1000

6 1000

1774 x 165 x 48

924 x 165 x 48

1364 x 165 x 48

8

5

6

1000

1000

1000

PLUG

YES

YES

NO

YES

YES

240 1774 x 165 x 48 8 1000 NO

High intensity electric radiant overhead heater with high surface area profiled alloy

Refer to model code chart above

230-240 Volts Nominal at 50—60 Hertz, Single Phase

3 Core Cable 2.5mm

2

CE

MINIMUM

RECOMMENDED

MAXIMUM

2.1 m

2.3 m to 2.7 m

3.0 m (For higher ceiling heights, units can be lowered using optional bracket kits or refer to the Heatstrip Max range)

Suitable for ceiling, wall, beam, fixed umbrella and recess mounting. Also available for extension mount using rigid fixing poles and chain mount bracket.

IP55 Protection from water ingress from all directions

Australia

THH1500AEU

THH2400AEU

THH3200AEU

5

Spot Heating Principle

In most outdoor or difficult-to-heat indoor applications, therefore are 2 options when looking at the size and quantity of the heater required. Option 1 is to comfort heat the entire area based on the total dimensions of the space, regarding of whether the entire area is being fully occupied. Option 2 is to spot heat the high use areas, such as over outdoor tables, BBQ’s, lounges, assembly lines or indoor workstation.

Often it is more practical and efficient to spot heat these areas. Spot heating will help to reduce the initial capital cost, as well as the running costs. Spot heating will allow the area to be “zoned”, meaning heating only the areas that are being used, such as tables in a restaurant or outdoor alfresco area.

The top table shows a comparison between spot heating over a table, or heating an entire area.

The bottom table shows the flexibility of using HEATSTRIP to provide a comfortable environment, even when the layout of the area is very unusual.

6

BBQ

LOUNGE

BAR STOOLS

DINING TABLE

BAR

3500

1800

THH3200

2700

1800

THH3200

Radiant Footprint

HEATSTRIP electric heaters produce radiant heat which heats objects rather than the air. Therefore, it is imperative that objects to be heated (ie. people), are within the direct radiant footprint of the heater.

The diagram to the left shows the radiant footprint of

HEATSTRIP Design, and is an approximate guide based on a fully enclosed, outdoor environment.

25°C

54°

This diagram shows that the maximum heat output is found directly under the heater, and the temperature decreases as you move away from the heater.

It highlights the importance of maintaining recommended mounting heights, and if possible, positioning the heater directly above the area to be heated.

1400

2000

23°C

Also, the temperature (ie. surface temperature) is the same for all 3 models, regardless of the wattage. However, as

2800

21°C the size increases and the length of the unit increases, the radiant footprint will be larger.

The below diagrams show the approximate heating area for each model, based on both an indoor and outdoor enclosed environment, with direct overhead mounting.

Radiant footprint is reduced in angled, wall mounted applications.

HEATED AREA

INDOOR SPOT HEATING

1600

900

2600

1400

3500

1800

THH1500AEU

HEATED AREA

OUTDOOR ENCLOSED AREA

1300

900

THH2400AEU

2000

1400

THH3200AEU

2700

1800

THH1500AEU THH2400AEU THH3200AEU

7

8

Selection Guide

Prior to selecting the exact model and quantity required for your application, please ensure the correct range of Heatstrip heaters is being used.

Below is an overview of the Heatstrip options.

HEATSTRIP Max (THX models) is an ultra high temperature heater used for uncovered or open areas with a mounting height of 2.4 m to 3.5m. Also suitable for difficult indoor environments such as showrooms, production lines, warehouses etc.

HEATSTRIP Design (THH models) is a premium high temperature heater and is primarily used for outdoor rooms where there is 1,2 3 or 4 enclosed sides, with an ideal mounting height of 2.1 m to 2.7m. Ideal for hard to heat indoor applications or moist environments where an IP55 rating is required.

HEATSTRIP Indoor (THS models) is a medium intensity heater used for protected indoor applications, such as sunrooms, school classrooms, halls, gymnasiums etc.

General recommendations for HEATSTRIP Design:

 Ideal mounting height: 2.1m to 2.7m. Maximum is 3m in a protected outdoor environment.

Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table)

Based on the radiant footprint of the previous page, for a protected outdoor area, a minimum of 500W/m2 is required. For indoor spot heating, a minimum heating capacity of 400W/m2 is recommended.

The below table outlines the coverage of each HEATSTRIP Design model (in m 2 ), based on 3 different scenarios, with direct overhead mounting. For example, for an outdoor area that is protected from prevailing winds by walls, café blinds etc, Model THH1500AEU will cover 3m

2

and Model THH2400AEU will cover 4.8m

2

.

For angled wall mounting applications, the coverage can be reduced by up to 40%. The maximum heat projection from the wall is 2m.

MODEL INDOOR PROTECTED (m2) OUTDOOR ENCLOSED (m2) OUTDOOR EXPOSED (m2)

THH1500AEU

THH2400AEU

THH3200AEU

3.75

6

8

3

4.8

6.4

2.5

4

5.3

Table Layout

For the majority of outdoor applications, the most effective method is to spot heat a table or similar area. The below diagrams provides an easy selection guide for the approximate model and quantity of heaters required to heat common residential table settings.

Selections are based on HEATSTRIP door area.

Design being mounted at 2.4m from the floor and an undercover fully enclosed out-

THH1500AEU

THH2400AEU

THH2400AEU THH3200AEU

THH3200AEU THH3200AEU

2 x THH3200AEU 2 x THH2400AEU

9

Installation Requirements

The ideal mounting position for the HEATSTRIP possible, HEATSTRIP

.

Design is on the ceiling, directly above the area to be heated. If this is not

.

can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of 2.1m to 2.7m and the table is within 2.5m of the wall.

For mounting heights more than 3m, we recommend the use of the optional accessories to reduce the height of the heater to 2.3m - 2.7 m. This will increase the effectiveness of your HEATSTRIP . Refer to the Mounting Accessory section for more information.

Electrical connections/GPO’s should not be located at the back of the heater. They should be located outside the physical footprint of the units to minimize heat build-up behind the units.

If the heater is to be mounted on an incline (eg. Vaulted ceiling), ensure the electrical connection is located at the lowest point of the heater.

Incorrect Installation Correct Installation

10

CEILING

The heating surface must never be directed toward the ceiling

CEILING

CEILING

Installation Location

the below diagrams confirm the minimum recommended clearances.

LIGHT, FAN OR SPRINKLER MUST

NOT BE BELOW THE HEATER

CEILING

1500 Min.

60 Min.

2100 Min.

1000 Min.

SURFACE BELOW HEATER

FLOOR

ANGLED WALL INSTALLATION

LIGHT, FAN OR SPRINKLER MUST

NOT BE BELOW THE HEATER

CEILING

60 Min.

300 Min.

1000 Min.

1000 Min.

2100 Min.

SURFACE BELOW HEATER

Wall

Wall

60 Min.

CEILING

FLOOR

CEILING INSTALLATION

LIGHT, FAN OR SPRINKLER MUST

NOT BE BELOW THE HEATER

60 Min.

1500 Min.

2100 Min.

60 Min.

Wall

1000 Min.

SURFACE BELOW HEATER

FLOOR

ANGLED CEILING INSTALLATION

11

150 mm MINIMUM

Mounting Options

The installation of HEATSTRIP Design is simple and easy with the standard mounting brackets supplied. For other more challenging locations there are a range of mounting options available - refer to below diagrams.

The HEATSTRIP Design can be mounted directly to the ceiling, angled downwards on a wall, fitted flush with the ceiling; suspended on chains or poles; attached to beams or poles; mounted end-to-end, or 2 units together.

Refer to the following pages for more detailed information on each mounting option.

CEILING

TWIN MOUNT

BRACKET

STANDARD

BRACKET

BEAM/POLE

MOUNT

BRACKET

FLUSH

MOUNT

ENCLOSURE

EXTENSION

MOUNT

BRACKET

SUSPENSION

MOUNT

BRACKET

12

Standard Mounting Brackets

The HEATSTRIP Design comes with a pair of standard mounting brackets. These adjustable brackets allow direct ceiling or wall mount, and come with preset angle options of parallel, 22.5° and 45°.

CEILING

45°

END VIEW

MODEL “B”

MINIMUM DISTANCE (mm)

THH1500AEU

THH2400AEU

THH3200AEU

22.5°

550

1000

1470

PARALLEL 22.5°

22.5°

45°

22.5°

B

45°

Ø7

100

PART No

ZBRAK-103

PACKAGED

DIMENSIONS (mm)

125 x 150 x 40

WEIGHT (kg) MATERIALS

STANDARD MOUNTING BRACKET

165,5

0.2 ALLOY

13

25

14

Flush Mount Enclosure

The Flush Mount Enclosure is an ideal way to neatly install the HEATSTRIP Design into a ceiling. They are available for all HEATSTRIP Design models, and are supplied as a one-piece unit for mounting of heaters. Flush mounting can be used with plaster or wood lined or concrete ceiling materials.

An ideal mounting height is 2.5m-2.7m, with a maximum ceiling height of 3.0m in an outdoor enclosed environment.

Maximum mounting heights should be strictly followed, otherwise the performance of the units may be reduced.

The facia of the enclosure is manufactured from 316 Stainless Steel and the rear casing is black zinc coated steel.

Please refer to the Installation Manual for more detailed installation information.

Safety

Do not allow any cables, furnishings, flammable materials or other items come in contact with any surface of the Flush

Mount Enclosure.

The Flush Mount Enclosure needs to be installed as per the installation instructions paying special attention to the minimum clearances. The heater needs to be mounted on a rigid bracket or fixing.

Maintenance Flush Mount Enclosure

The Flush Mount Enclosure is made from durable materials, however regular care and maintenance of your product will help prolong its life.

It is recommended that you wipe down your Flush Mount Enclosure and with a soft cloth gently wipe the surfaces of the Flush Mount Enclosure with a mild detergent to remove the built up contaminants from the environment. Then with a clean cloth ensure all detergent is removed.

All chemicals in the atmosphere including cigarette smoke, pollution etc. will tarnish the surface of the Flush Mount

Enclosure. In this case, additional cleaning and maintenance may be required. The cleaning process at least every three months will reduce the amount of build up and keep it looking as best it can. If the Flush Mount Enclosure is in a corrosive environment eg. salt spray, we recommend that you clean the Flush Mount Enclosure every week.

Before cleanings or inspection activity, the heater must be switched off and cooled down completely.

Do not use any abrasive materials or products to clean the Flush Mount Enclosure, this includes solvents, citrus based cleaners or other harsh cleaning products.

When handling the Flush Mount Enclosure, ensure that your hands are clean or that you use clean gloves as grease or dirt can mark the surface of the heater.

Do not use high pressure water to clean Flush Mount Enclosure. It is not recommended to hose down the Flush

Mount Enclosure and heater as water may get into the roof cavity.

VIEW FROM TOP VIEW FROM UNDERNEATH

Flush Mount Enclosure Dimensions

"B"

"A"

"C"

PART No “A” (mm) “B” (mm) “C” (mm)

THHAC-009 1030 974 970

THHAC-011 1470

THHAC-012 1880

1414

1824

1410

1820

226

170

Ø8

280

SUITABLE FOR

MODELS

THH1500AEU

THH2400AEU

THH3200AEU

PART No

THHAC-009

HOLE CUTOUT

DIMENSIONS (mm)

980 x 230

OVERALL

DIMENSIONS (mm)

WEIGHT

(kg)

1030 x 280 x 125 5.5

THHAC-011

THHAC-012

1420 x 230

1830 x 230

1470 x 280 x 125

1880 x 280 x 125

8

9

15

Flush Mount Enclosure Installation Clearance Dimensions

Shown in the diagrams below are the minimum clearance required for the installation of the Flush Mount Enclosure.

It is imperative that all cables, backing materials, insulation and other materials are keep clear of the back and the sides of the Flush Mount Enclosure. The clearance dimensions are the same for all building rated materials.

16

CONCRETE CEILING

ROOFING MATERIAL

CLEARANCE DIMENSIONS

HEATER

BRACKET x2

"D"

"D"

ON

OFF

PLASTER CEILING

TIMBER BATTEN

FLUSH MOUNT ENCLOSURE

SCREWS, AT EACH END, THERE ARE 6 HOLES

WITH A DIAMETER OF 8mm EACH

Installation Instructions

Ensure all minimum clearance requirements are met and the materials used are compliant to your local building codes.

Before installing the Flush Mount Enclosure, ensure the site to be fixed is fully prepared with the hole cut the correct size and the mounting points securely in place.

STEP 1: Attach the brackets to the rear of the heater. The dimensions for the spacing of the brackets is listed in the table.

STEP 2: Screw the Flush Mount

Enclosure into the side of the hole.

NOTE: screws are not included.

STEP 3: If there is no roof access, connect the heater to the power source, ensure the power is OFF.

STEP 4: Lift the heater into the

Flush Mount Enclosure ensuring the brackets are to the side of the mounts

STEP 5: Push the heater to the left ensuring the brackets engage in the mounts. It will then drop in. Shake the heater to ensure that it is securely mounted.

ON

OFF

"D"

SIDE OF HOLE

MODEL

THH1500AEU

THH2400AEU

THH3200AEU

“D”

DISTANCE FROM END

TO BRACKET (mm)

HEATER

FLUSH MOUNT ENCLOSURE

150

370

425

BRACKET x2

"D"

SCREWS, AT EACH END, THERE ARE 6 HOLES

WITH A DIAMETER OF 8mm EACH

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

17

END TO END MOUNTING BRACKET

TWIN MOUNT BRACKET

Pole / Beam Mounting Kit

BEAM or POLE

SCREWS

(NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

OFFSET MOUNT

20 MINIMUM

BEAM or POLE

SCREWS

(NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

NARROW CENTERED MOUNT

175 MAXIMUM

BEAM or POLE

SCREWS

(NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

WIDE CENTERED MOUNT

BEAM or POLE

POLE/BEAM MOUNTING BRACKET

HEATER

TRANSVERSE MOUNTED

20 MINIMUM

POLE

NUT & BOLT (NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

NARROW CENTERED MOUNT

Screws for connection to the beam or pole are not included.

Minimum pole diameter 20mm.

Maximum pole diameter 70mm.

This mounting option is suitable for umbrella struts.

The beam/pole can be placed directly on top of the mounting bracket. No clearance is required from the top bracket to the bottom of beam/pole .

The optional Pole/Beam mounting bracket kit can be used to mount HEATSTRIP Design onto wooden beams, rafters, poles, umbrellas struts etc.

5mm HARDWARE

70mm Maximum

A

A

DETAIL A

ENCLOSURE

MOUNTING CLIP

HEATER

B

NOTE: TO POSITION HEATER IN ENCLOSURE:

1. FIX MOUNTING BRACKETS ON THE HEATER IN LINE WITH MOUNTING CLIPS IN ENCLOSURE.

2. LIFT HEATER INTO ENCLOSURE ABOVE RETAINING FOLD IN THE CLIP.

3. SLIDE BRACKETS OVER CLIP AND DROP BRACKETS INTO THE CLIPS.

18

PART No

THHAC-001

PACKAGED

DIMENSIONS (mm)

150 x 150 x 50

WEIGHT

(kg)

MATERIALS

0.5 316 SS

Twin Mounting Bracket

The optional Twin Mount bracket allows for two (2) units of HEATSTRIP

Design to be mounted side-by-side, either in parallel or angled as per the diagram on the right. This is ideal for applications when a wider heat coverage is required, or when there is mounting restrictions/limitations

(such as running between 2 rows of tables etc.)

The Twin Mount bracket can also be used with the Extension Mount bracket and Pole Kit, to lower the units from a high ceiling.

PART No

THHAC-016

PACKAGED

DIMENSIONS (mm)

300 x 50 x 50

WEIGHT

(kg)

0.25

MATERIALS

316 SS

19

SPECIFICATIONS WITHOUT NOTICE.

VIEW FROM SIDE

End to End Mounting Bracket

The end to end bracket allows multiple units to be joined in a straight line for maximum heat performance and aesthetic appeal. This is ideal for applications such as long rows of tables and assembly lines, where a constant heat coverage is required.

The bracket allows for a 50mm gap between units and an opening for the power connection. As per the diagram below, units should be mounted with the power leads together.

The end to end bracket can be used with either the standard ceiling/wall mount bracket or the extension bracket & pole kit.

EXTENSION MOUNT KIT WITH POLES

50

20

PART No

THHAC-017

PACKAGAED

DIMENSIONS (mm)

300 x 150 x 50

WEIGHT

(kg)

0.5

MATERIALS

316 SS

END TO END BRACKET

BEAM or POLE

SCREWS

(NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

OFFSET MOUNT

20 MINIMUM

BEAM or POLE

SCREWS

(NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

NARROW CENTERED MOUNT

175 MAXIMUM

BEAM or POLE

SCREWS

(NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

WIDE CENTERED MOUNT

BEAM or POLE

POLE/BEAM MOUNTING BRACKET

HEATER

TRANSVERSE MOUNTED

20 MINIMUM

POLE

NUT & BOLT (NOT INCLUDED)

POLE/BEAM MOUNTING BRACKET

HEATER

NARROW CENTERED MOUNT

70mm Maximum

5mm HARDWARE

Suspension Mount Bracket

The Suspension Mount bracket provides a cheap, easy and effective option for lowering the HEATSTRIP

Design from high ceilings. If the ceiling height is more than 3.0m is an enclosed outdoor environment, or 2.7m in an exposed site, it is recommended to lower the heaters to an ideal mounting height of 2.3m—2.7m.

The bracket is designed to be used with chains or wires.

There can be multiple chain/wire arrangement options, as per the below diagram.

Note: chains or cable are not supplied with the heaters

SUITABLE FOR

MODELS

THH1500AEU

THH2400AEU

THH3200AEU

PART No

THHAC-002

THHAC-003

PACKAGED

DIMENSIONS (mm)

700 x 150 x 50

1200 x 120 x 50

WEIGHT (kg) MATERIALS

1

2

316 SS

316 SS

21

END TO END BRACKET

Extension Mount Bracket

The Extension Mount bracket allows HEATSTRIP Design units to be lowered from high ceilings, using rigid connections. The brackets are for use with 25mm x 25mm x 1mm tube (SHS), and can be supplied as brackets only for customising the length of the drop on site; or supplied as a complete kit with brackets, pre-cut poles and connections. The standard length options as part of the kit are 150mm, 300mm, 600mm and 1200mm.

The kits include all brackets, poles and screws necessary for connection to the heaters, however it does not include screws for attachment to the ceiling.

CEILING

22

PART No

THHAC-004

THHAC-005

THHAC-006

THHAC-007

THHAC-008

45°

END VIEW

NOTES PACKAGED

DIMENSIONS (mm)

150 x 150 x 50

WEIGHT

(kg)

1

MATERIALS

316 SS

300 x 150 x 50

600 x 150 x 50

900 x 150 x 50

1200 x 150 x 50

2

2

2.5

3

316 SS

316 SS

316 SS

316 SS

Brackets only

(for use with 25x25x1mm tube)

Kit includes 2x300mm extension pole, screws and brackets

Kit includes 2x600mm extension pole, screws and brackets

Kit includes 2x900mm extension pole, screws and brackets

Kit includes 2x1200mm extension pole, screws and brackets

22.5° PARALLEL

Wall Controller with Remote Control

This controller is a custom designed and manufactured controller for HEATSTRIP . It has been designed for ease of use to ensure economic running costs of your heater. It provides a timer for automatic heater operation.

The timer function has four settings. It can turn the heater on for 1 hour, 2 hours, 4 hours or constantly on.

The timer can be operated where it is installed or via remote control unit. It has pre set timing for 1 hour, 2 hours or hours or continuous, allowing the heater to operate continuously.

The remote control has a range of 10 metres and must be within line of sight of the wall switch.

Controlling multiple units

It is possible to use one wall controller to control multiple heaters up to 16 Amps load. The wall controller is rated at 16

Amps and 220-240 volts. For larger current draw, it is recommended that you talk to your electrician who can use a relay to connect more units.

Mounting

The TT-MTR is designed to fit into a standard European wall gangbox. It will just as easily fit into a plaster wall. Your electrician can install this device.

The controller needs to be installed according to your local wiring guidelines.

Operation

Press “ON/OFF” button to turn power on and off.

Press “TIMER” button to set timer to 1, 2, 4 hours operation. The timer indicator light will show which time setting is selected. The timer will start the heater and automatically turn it off at the preselected time.

Safety

The TT-MTR controller must be installed in a dry location. It is not suitable for installation where rain or water could affect the unit..

Ensure the connections are properly connected.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.

Maintenance

The TT-MTR Controller is made from durable materials, however regular care and maintenance of your controller will help prolong the life of the product.

It is recommended that you dust the controller to keep the surface clean. The cleaning process at least every three months will reduce the amount of build up and keep it looking as best it can.

Do not use any abrasive materials or products to clean the controller, this includes solvents, citrus based cleaners or other harsh cleaning products. Do not use water or a damp cloth to clean the controller.

When handling the controller, ensure that your hands are clean or that you use clean gloves as grease or dirt can mark the surface of the controller.

MODEL

TT-MTR

MAXIMUM

VOLTAGE (Volts)

220—240

MAXIMUM

CURRENT (Amps)

16

PACKAGED

DIMENSIONS (mm)

80 x 80 x 42

WEIGHT (kg)

0.5

23

WALL CONTROLLER INSTALLATION GUIDE

GANG BOX

WALL

SCREW

TT-MTR

24

IN SWITCHBOARD

ACTIVE

NEUTRAL

EARTH

CIRCUIT

BREAKER

15 Amp

RCD

FIELD WIRING

ISOLATOR

TT-MTR

WALL CONTROLLER

MAXIMUM 16A

10.2A

ACTIVE

NEUTRAL

EARTH

IN SWITCHBOARD

CIRCUIT

BREAKER

15 Amp

RCD

FIELD WIRING

ISOLATOR TT-MTR

WALL CONTROLLER

MAXIMUM 16A

RELAY

13.6A

ACTIVE

NEUTRAL

EARTH

ACTIVE

NEUTRAL

EARTH

15 Amp

ACTIVE

NEUTRAL

EARTH

15 Amp

15 Amp

ISOLATOR

ISOLATOR

ISOLATOR

13.6A

13.6A

13.6A

1 x THH2400A

THH2400A

HEATER

4 x THH3200A

THH3200A

HEATER

THH3200A

HEATER

THH3200A

HEATER

THH3200A

HEATER

Safety

HEATSTRIP Design has an IP rating of 55. This means it is safe for water ingress from all directions. The HEATSTRIP can be safely hosed down.

HEATSTRIP has undergone extensive testing both in laboratory conditions; in Thermofilm’s manufacturing facility in

Melbourne and field trials in Australia and overseas. It has been this testing that gives the purchaser the confidence of a high quality product.

Independent laboratory testing has confirmed Thermofilm’s full compliance with Australian and other International

Standards. This includes CE, AS/ANZ, UL/CSE

The heater comes in both plug (1500W, 2400W) and hardwired (3200W) versions. In both cases the fixed wiring must be installed by a licensed electrician in accordance with the relevant wiring regulations.

HEATSTRIP is Class 1 equipment and must be earthed.

In operation, this heater is VERY HOT— do not touch any part of the heater while it is turned on. Do not touch any part until 30 minutes after it is turned off.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.

Do not allow any cables, furnishings, flammable materials or other items come in contact with any surface of the heater.

If installed in wet areas, the heater switches or controls must be located so that they cannot be touched by persons in the bath or shower.

The heater needs to be installed as per the installation instructions paying special attention to the minimum clearances.

The heater needs to be mounted on a rigid bracket or fixing.

The heater must not be mounted immediately below or in front of a socket outlet.

In case of a heater fault or damaged supply lead, the appliance should be returned to the point of purchase for return to

Cook & Heat B.V. for repair.

Maintenance

The HEATSTRIP Design is made from durable materials, however regular care and maintenance of your heater will help prolong the life of the heater.

It is recommended that you hose down the heater and with a soft bristle brush, gently wipe the surfaces of the heater with a mild detergent to remove the built up contaminants from the environment. Then rinse all detergent off the heater.

All chemicals in the atmosphere including cigarette smoke, pollution etc. will tarnish the surface of the heater. In this case, additional cleaning and maintenance may be required. The cleaning process undertaken at least every three months will reduce the amount of build up and keep it looking as best it can. If the heater is in a corrosive environment eg. salt spray, we recommend that you clean your heater with a light spray of fresh water every week. After cleaning, turn the heater on for 20 minutes to dry any water residue and prevent water staining.

Before cleaning or inspection activity, the heater must be switched off and cooled down completely.

Do not use any abrasive materials or products to clean the heater, this includes solvents, citrus based cleaners or other harsh cleaning products.

When handling the heater, ensure that your hands are clean or that you use clean gloves as grease or dirt can mark the surface of the heater.

Do not use high pressure water to clean heaters, light water spray only.

25

26

Warranty Terms & Conditions

The below Warranty Terms and Conditions apply for international warranty only.

Cook & Heat B.V. warrants to the original owner that HEATSTRIP Design products will be free from defects in materials and workmanship for a period of 24 months from the date of purchase in accordance with the following warranty terms and conditions.

Provision of this warranty is subject to:

 The HEATSTRIP product must be installed in accordance with the Installation Instructions and relevant electrical standards and codes.

 The HEATSTRIP product must be maintained and cleaned according to instructions detailed in the Installation Manual.

 There is no warranty expressed or implied with regard to capacity requirements. The selection of the unit or units depends entirely upon the system design and capacities as determined by the purchaser.

 The customer has not repaired, opened or altered the product in any unauthorised manner.

 This warranty excludes damage to the product or components arising from circumstances outside the control of Cook &

Heat B.V., including, but not limited to, where the product is not used for intended purpose; where the product has been rectified in any way; incorrect installation; incorrect power supply; damaged caused during delivery; misapplication, misuse, abuse, vandalism, lack of maintenance or accident.

 Cook & Heat’s obligations under this warranty are limited to repair or replacement at Cook & Heat B.V. of any components of the product which Cook & Heat B.V. identifies to its satisfaction to be defective.

 Transportation charges involved in return of the product to Cook & Heat B.V. is the sole responsibility of the customer.

 All products are inspected and tested before despatch and are at the risk of the purchaser after the shipment from Cook

& Heat B.V., if not delivered by Cook & Heat B.V. to destination.

 Discolouration of the surface may occur after a period of time, this does not constitute a warrantable event.

 Twisting and bending of the heaters may occur, this does not constitute a warrantable event.

 No products or components will be supplied in advance of an examination of the faulty product or components by Cook &

Heat B.V. or an authorized representative of Cook & Heat B.V.

 Cook & Heat B.V. does not participate in any site related costs or labour expenses incidental to replacement of parts, repairing, removing, installing, servicing, transportation or handling of parts to complete products, and assumes no liability on parts repaired or replaced without written authorisation. Cook & Heat B.V. shall not be liable for any default or delay in performance of its warranty obligations caused by any circumstances beyond its control, including, but not limited to, judicial or government restrictions, strikes, fires, floods, abnormal weather conditions, delayed supply of components.

Should products be determined as damaged on arrival, immediately notify the transport company of the condition and have them noted on the freight documents. If damage is discovered after unpacking, demand immediate inspection by the transportation company and insist that a record of the damage is made on the freight documentation.

The customer warrants using the product in accordance with:

 Any instructions provided to it by Cook & Heat B.V. from time to time.

 All government and local regulations, including but not limited to all relevant electrical, environmental laws and regulations governing the installation, storage, use, handling and maintenance of the goods.

 All necessary and appropriate precautions and safety measures relating to the installation, storage, use, handling and maintenance of goods.

DISTRIBUTOR DETAILS FOR

EUROPE & UNITED KINGDOM

Distributed by:

Cook & Heat B.V. www.heatstrip.eu

Manufactured by:

Thermofilm Australia Pty. Ltd.

17 Johnston Court

Dandenong South,

Victoria, 3175 Australia

advertisement

Related manuals

Download PDF

advertisement