Qolsys QS1431-840 IQ GLASS-S Installation Manual
QOLSYS QS1431-840 is a wireless glass break sensor compatible with the Qolsys IQ Panel 2 security system. It offers 20ft maximum and 5ft minimum detection range. Easily adjust its sensitivity with two dip switches. It can be mounted on ceilings or walls between 6.5ft and 8.5ft above the floor. Secure your home or business with this reliable glass break detector.
Advertisement
Advertisement
IQ GLASS S-LINE INSTALLATION MANUAL
IQ GLASS-S
SPECIFICATIONS
Sensor: 2.75”H x 3.88”W x 1.5”D
Compatible control panels: Qolsys IQ Panel 2
Frequency: 319.5MHz
Battery: 3V GP CR123A (x2)
Operating Temperature: 14°F to 122°F
Detection Range: 20ft Max and 5ft Min
Intended for use with IQ Panel 2
Supervisory signal interval: 70 min (approximately)
Intended for use with 3/16” and 1/4” plate or tempered glass.
Note: For UL/CUL installations use this device only in conjunction with compatible Qolsys wireless alarm system IQ Panel 2.
STEP
1
CHOOSE
INSTALLATION
LOCATION
✓ Ceiling
✓
Walls
Ceiling mount
STEP
2
SECURE
TO
SURFACE
Mounting Height:
The sensor should be mounted between 6.5ft and 8.5ft above the floor.
All protected glass must be within a clear line of sight of the sensor and within the 20ft max range.
STEP
3
DETACH
FACE
PLATE
STEP
4
REMOVE
BATTERY
TAB
Wall mount
STEP
5
REPLACE
FACE
PLATE
Note: for UL/cUL listed the device shall be secured using the provided mounting screws.
STEP
6
LEARN
INTO
PANEL
Note: Detector LED will flash rapidly for 5 minutes as part of initial power up sequence.
Place your panel in
“autolearn" mode
Open and close the case to “tamper” the device
ADD
Customize name and settings as desired and touch “ADD”
STEP
7a TESTING
MODE
Sensitivity :
Two dip switches allow you to customize the sensitivity and detection range of the IQ Glass S. The factory default is set to
MAX. Please refer to the table below to customize the sensitivity.
Switches :
Set dip switches based on desired detection range.
SENSITIVITY
MAX
MEDIUM
LOW
LOWEST
DETECTION RANGE
20ft
13ft
8ft
5ft
1
OFF
OFF
ON
ON
2
OFF
ON
OFF
ON
FG-701
Glassbreak Simulator
To properly test the IQ Glass-S sensor, the
FG-701 Glassbreak Simulator is required.
STEP
7b TESTING
MODE
Test Mode:
Place the sensor in test mode by disconnecting the batteries for 30 seconds then reconnecting. Test mode is active for 5 minutes upon the sensor powering on. The LED blinks every second when the sensor is in test mode. The IQ Glass-S does not transmit an RF Signal while it is in Test Mode. Please refer to the table on the right for the LED indicator guide. The sensor will exit test mode after the first 5 minutes of power up.
LED Indicator Guide:
CONDITION
Initial Power Up
Test Mode
Test Mode, alarm event
Normal Mode, alarm event
Low Battery
ON
2 1
RED LED
Flash rapidly for 5 minutes
Flash once per second
Rapid flash for 2 seconds
SOLID for 5 seconds
Flash once every 30 seconds
STEP
7c TESTING
MODE
1.
Set the FG-701 switches to the TEST and MANual modes.
2.
Position the FG-701 near the protected glass and point the speaker directly at the glass break detector.
IMPORTANT : If window coverings are present, close them fully and hold the FG-701 behind the window coverings for testing.
3.
Press the red start button and the FG-701 will generate a burst of glass break audio.
If the LED on the IQ Glass-S sensor flashes rapidly for
2 seconds an alarm event has been detected and the range is acceptable for audio. If the LED does not flash, position the IQ Glass-S closer to the glass and try again.
Note: The IQ Glass-S does not transmit an RF Signal while it is in Test Mode.
ACTIVATE
Red Start
Button
TEST FLEX MAN
CONNECTS
USING
SECURE
319.5 MHz
Document#: IQGS-IM-02-18
Revision#: 2/14/18
Issue Date: FEB 2018
Qolsys Product #: QS1431-840
Equipment
BP21056
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2ABBZ-RF-ARGB
IC: 11817A-RFARGB
GOT QUESTIONS?
CONTACT TECH SUPPORT
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et
(2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.