Paxton Switch2 Control Unit Access Control User Guide
Paxton Switch2 Control Unit is a versatile access control system that provides secure and convenient entry to various types of properties. With its ability to support up to 10,000 users, 50 codes, and 3,000 PINs, it offers a scalable solution for small to medium-sized businesses or organizations. The system allows for flexible configuration with multiple operating modes, including card-only, code-only, or a combination of both.
Advertisement
Advertisement
22/01/2013
Ins-30010 Switch2 control unit
Paxton
Technical Support
01273 811011
[email protected]
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Quickstart guide
This supplement is a brief guide to installing a Switch2 system. Further information is available for download at: http://paxton.info/45 or call the communications team on: 01273 811011.
Wiring
Reader
12V
Red LED
Amber LED
Green LED
0V
Contact
Exit
Data
Clock
Media Detect
Switch2 http://paxton.info/107
PLACE SERIAL
N.C.
N.O.
COM
Bell
12V
0V
LABEL HERE
Fail closed release
*
(for Paxton exit buttons
GREEN and RED wires go to reader terminals) Exit button
Black/0V and Exit
(push to make)
To change a reader port voltage to 5V, move the red jumper(s) located beneath the wiring label to the 5V setting.
Fail open locks
For a fail open lock (Maglock), wire 0V to the "N.C." terminal instead of "N.O."
This product is not suitable for retail sale. All warranties are invalid if this product is not installed by a competent person.
Page 1
INITIALISING A NEW SYSTEM
The first time the system is powered up the control unit will beep 3 times a second.
This indicates the unit needs programming. There are 3 programming options:
Using tokens only (CARDLOCK or PROXIMITY) see Section 1
Using codes only (TOUCHLOCK) see Section 2
Using tokens and PIN/codes (CARDLOCK/PROXIMITY with TOUCHLOCK) see Section 3
The reader's default indication has all the LED's on. Access granted is denoted with a single flashing Green LED. Access Denied is a single flashing Red LED.
Section 1 - CARDLOCK or PROXIMITY
Enrolling a card pack.
Present/swipe enrolment card
RD en t c ard
FUNCTION CA en
1.
At in ro llat lm en
Y t c ard
to
th e ack s rea de r to
va lida te th e t ok s in en te a
us er tok
th is p validat er tok en,
2.
To re
pr ea der ese
fo nt th llow is e
by
th e
1. A ard
2. T
to
th o ree r lidate a us
/pa xto
/74 follo wed b y the use
-va r to
Mo lida en rolm en t c re i nfo
: htt p:/ cce ss ken.
Pa
user to ar d All tokens will now be validated.
Tokens can now be issued to users
Adding an additional Proximity card pack.
You need to be in possession of a valid enrolment card for this system. Present this enrolment card to the reader and the Amber
LED will flash with the Green & Red LED's off. Present the Enrolment card from the new card pack. The reader will beep and all LED's will be lit. The additional cards will now be valid. Repeat this with each reader and with any additional card packs. Any valid enrolment card can be used to add further packs. If an incorrect enrolment card is used to start the process, the Red LED will be lit and the reader will produce a squeak sound as it rejects the card.
To bar a user: Present/swipe user's shadow card
The user card is now barred
A user can be re-validated by showing the enrolment card followed by the user card or re-entered if used in Card+PIN mode.
Section 2 - TOUCHLOCK
Choose a 6 digit Programming Code and load this into the unit as follows:
DO NOT USE 123456 - The default User Code (1234) will open the door before the Programming Code had been fully entered.
6 digit Programming
Code
6 digit Programming
Code
The default user code is now set to 1234
You can now set up the user codes and features using the programming chart.
Enter 6 digit
Programming
Code
Example: - Setting a user code to unlock the door under Normal conditions.
8 Enter user code
4-8 digits
Re-enter user code
Hold for 3 secs
4
Normal
FACTORY RESET
1. Disconnect power
2. Disconnect GREEN and MAUVE wires
3. Insert link wire between GREEN and MAUVE terminals
4. Reconnect power - unit will beep 4 times
5. Disconnect power
6. Remove link wire
7. Reconnect GREEN and MAUVE wires
8. Reconnect power - unit will beep 3 times a second
9. Proceed with Initialising a new system
This box can be used to write down the Programming Code for future reference.
Ensure that this information is stored in a secure place.
Page 2
START - Enter the 6 digit Programming Code and hold down a function key for 3 seconds. - The unit beeps and the LED flashes faster.
Continue the key sequence to set the option - The keypad returns to operating mode.
Set a user code
Combined Card &
Keypad modes
Door open time
(seconds)
8
Single or multiple codes
Silent operation
20 wrong keystrokes
= 60 second lockout
Exit button
Change
Programming Code
Data Reset (except
Programming code)
2
7
6
3
4
9
1
5
Enter user code
4-8 digits
See Section 3
Re-enter user code
OR
OR
OR
8
2
4
6
= Normal
= Toggle
= Duress
= Delete X X
Enter time in seconds
(default = 07, max = 60)
2
One code only OR
2
2
2
Beep on
OFF
Enter 6 digit
Programming Code
Enter 6 digit
Programming Code
OR
OR
Open door for time in option 5
OR
9
6
Multiple codes allowed
6
6
Silent
ON
4
Toggle door open until pressed again or toggle code entered
Re-enter 6 digit
Programming Code
Function keys
= Hold down for 3 secs
Section 3 - CARDLOCK/PROXIMITY with TOUCHLOCK mode
(i) The KP reader must first be initialised in TOUCHLOCK mode : See Section 2
(Individual Toggle function is not available)
(ii) Set up the required operating mode, as follows:
Enter 6 digit
Programming
Code
1
Hold for 3 secs
(iii) Present enrolment card
1
Card plus PIN
OR
2
Card plus Code
OR
3
Card or Code
Card plus Code.
Access is granted by presenting a valid token and then entering a valid user code.
Card or Code.
Access is granted by presenting a valid token or entering a valid user code.
Touchlock programming - Function 2 to enable multiple user codes, Function 8 to add user codes. (4 digits)
Card plus PIN.
A card requires a 4 digit PIN to be assigned to it before it will work, as follows:
Present enrolment card
Present user card
Enter PIN Re-Enter PIN
FUNCTION CARD
1. At in rea de sta r to en llat
va
-va
2.
To re en rolm t c lm ion lida en ken
, p lida t c ard nfo ard res te th
:
Pa en e t te a
to o rehtt t th
th is c ok en
us er to e r ea
1. A t installation, p use
th is p
fo ens in this p
card to th r to
Mo re i
/pa s in ard ken der xto
to
pr n.i
th ese nfo ss en.
e ack is nt th ed
by ack.
/74 e
th e en,
card y the va lidate a user tok p:/ n A cce
user
tok validat llow
Amber flashes
Amber and
Green flash
LED's flash faster
Page 3
Technical Help
Here is the list of topics about this product that receive the most technical support enquiries.
We list them here to help you speed up the installation and trouble shooting process.
1 - How to reset the controller.
Q - See Main Text
2 - Two readers on the same controller.
Q Simply wire the PROXIMITY or CARDLOCK readers in parallel, colour for colour. It is possible to mix 5V
Q and 12V readers. The jumper on the Switch2 must be set to provide 5V at the Red terminal and the
Q 12V reader must then be powered directly from the 12V terminal.
3. - Replacing a white labelled control unit. (pre 2004 design)
Q On a White labelled unit the Red voltage terminal output was 5V DC. The new Yellow labelled unit has
Q this output set to 12V DC. For systems where 5V readers/keypads are to be used, readers must not be
Q connected to yellow label controllers until the jumper setting has been changed on the controller PCB.
Q NOTE: The Touchlock membrane keypad is not compatible with this control unit.
4 - Initialising with 2 keypads.
Q Either Keypad can be used to initialise the controller when using K-Series Keypads. Connect all wires in
Q parallel, colour for colour. If you are using the older Touchlock/SS then you must use the master keypad
Q which has the yellow wire connected to yellow terminal. (The slave keypad will have the yellow wire
Q connected to the mauve terminal.)
5 - Bell/Alarm Output.
Q A 12V DC alarm sounder can be wired between the 12V and Bell terminals. This output is capable of
Q driving a 12V bell/buzzer up to 1A. This load must be taken into consideration when selecting a suitable
Q rated power supply. If door contacts are fitted on a Switch2 system, across the Black and Contacts
Q terminals, the bell/alarm output is activated when the door is forced. On a Switch2 system using a
Q keypad, the bell would normally activate this output. However, when using a door forced alarm, the bell
Q on a keypad will not activate the bell/buzzer connected to this output.
Specifications
Electrical
Voltage
Current
Relay switchable voltage
Switchable current
Features
Number of Users
Number of Codes
Code length
Number of PIN's
Readers per interface
Door open time
Time zones (with additional time clock)
Access levels (Colour Zones)
Silent operation
Can be used with fail OPEN locks
Can be used with fail CLOSED locks
Exit button input
Door Contact input
Alarm/bell output voltage
Environment
Operating temperature
Waterproof
Dimensions
Control Unit
Plastic Cabinet
Min
11V DC
Min
1
Max
14V DC
80 mA
24V DC
4 A
Max
10,000
50
4 digits
1
1 sec
1
1
8 digits
3,000
3
60 secs
2
3
Yes
Yes
Yes
Yes
Yes
Yes
Min Max
-20 °C +55 °C
NO - If used externally, it must be protected in a plastic weatherproof housing
Width
71 mm
200 mm
Height
70 mm
200 mm
Depth
23 mm
75 mm
Page 4