Vacmaster VJc607pf Operator's Manual
The Vacmaster VJc607pf is a versatile wet/dry vacuum cleaner designed for both household and commercial use. With its powerful motor and durable construction, it can easily handle a wide range of cleaning tasks, from vacuuming up dust and debris to spills and liquids. The vacuum also features a variety of attachments, including a 2-in-1 utility nozzle, floor brush/squeegee, crevice nozzle, and reusable cloth and foam sleeve filters, making it suitable for cleaning a variety of surfaces and materials.
Advertisement
Advertisement
Operator’s Manual
Wet/Dry Vacuums
Model No.
VJC607PF 0101
FOR YOUR SAFETY
Read and understand this manual before use.
Keep this manual for future reference.
Distributed By
Cleva North America, Inc.
601 Regent Park Court
Greenville, SC 29607
Replacement Filters &
Accessories available at:
Vacmaster.com
TABLE OF CONTENTS
SECTION
Warranty ........................................................................................................................................
Safety Instructions and Warnings ..................................................................................................
Double Insulation Instructions .......................................................................................................
4
Extension Cords..............................................................................................................................
4
2
3
Unpacking and Checking Carton Contents.....................................................................................
5
General Assembly Instructions ......................................................................................................
6
Dry Vacuum Operation .................................................................................................................. 7
Liquid Vacuum Operation ..............................................................................................................
Blowing Operation .........................................................................................................................
8
9
Care And Maintenance ..................................................................................................................
10
Installing & Cleaning Reusable Cloth Filter ....................................................................................
11
Installing & Cleaning Foam Sleeve Filter .......................................................................................
11
Troubleshooting .............................................................................................................................
Exploded View ...............................................................................................................................
12
13
Parts List ........................................................................................................................................
14
Thank you for purchasing this Vacmaster® wet/dry vacuum cleaner.
Feel confident that with Vacmaster® you are obtaining a high quality product engineered for optimal performance. This vacuum is capable of picking up liquids and dry materials.
FOR YOUR SAFETY: CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS.
WARRANTY
We take pride in producing a high quality, durable product. This Vacmaster® product carries a limited two (2) year warranty against defects in workmanship and materials from date of purchase under normal household use. If product is to be used for commercial, industrial, or rental use, a 90 day limited warranty will apply. Warranty does not apply to defects due to direct or indirect abuse, negligence, misuse, accidents, repairs, alterations, or lack of maintenance.
Please keep your receipt as proof of purchase.
This warranty gives you specific legal rights, which may vary from state to state.
For product service call Customer Service at 1-866-384-8432.
2
SAFETY INSTRUCTIONS & WARNINGS
IMPORTANT SAFETY INSTRUCTIONS
READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM.
Read and understand this operator's manual and all labels on the Wet/Dry Vacuum cleaner before operating. Safety is a combination of common sense, staying alert, and knowing how your vacuum works. Use this Wet/Dry Vac only as described in this manual. To reduce the risk of personal injury or damage to your Wet/Dry Vac, use only Vacmaster® recommended accessories.
Household Type
SAVE THIS MANUAL
including the following:
FOR FUTURE REFERENCE.
When using an electrical appliance, basic precautions should always be followed
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
• Do not run vac unattended.
• Do not vacuum, or use this Wet/Dry Vac near flammable liquids, gases, or explosive vapors like gasoline or other fuels, lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, or
explosive dusts like coal dust, magnesium dust, grain dust, or gun power. Sparks inside the
motor can ignite flammable vapors or dust.
• Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Keep cord away from heated surfaces.
• Do not expose to rain. Store indoors.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not use with damaged cord, plug, or other parts.
• If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped
into water, return it to a service center.
• Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp
edges or corners.
• Do not run Wet/Dry Vac over cord.
• Do not handle plug or the Wet/Dry Vac with wet hands.
• To reduce the risk of health hazards from vapors or dusts, do not vacuum toxic materials.
• Do not use or store near hazardous materials.
• Do not use this Wet/Dry Vac with a torn filter or without the filter installed except when
vacuuming liquids as described in the operation section of this manual.
• Do not allow to be used as a toy. Close attention is necessary when used by or near children.
• To reduce the risk of injury from accidental starting, unplug power cord before changing or
cleaning filter.
• Do not leave Wet/Dry Vac unattended when plugged in. Unplug from outlet when not in use and
before servicing.
• Turn off Wet/Dry Vac before unplugging.
• Do not put any object into ventilation openings. Do not vacuum with any ventilation openings blocked; keep free of dust, lint, hair, or anything that may reduce air flow.
• Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
• To reduce the risk of falls, use extra care when cleaning on stairs.
• Unplug before connecting hose.
• Use only as described in this manual. Use only manufacturer’s recommended attachments.
• This appliance is provided with double insulation. Use only identical replacement parts.
See “DOUBLE INSULATION INSTRUCTIONS”.
When using as blower:
• Direct air discharge only at work area.
• Do not use Wet/Dry Vac as a sprayer.
• Do not direct air at bystanders.
• Keep children away when blowing.
• Use safety goggles.
3
SAFETY INSTRUCTIONS & WARNINGS
This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only identical replacements parts. Read the instructions for Servicing Double-Insulated Wet/Dry
Vacs before servicing. Use this Wet/Dry Vac as described in this manual. Observe the following warnings that appear on the motor housing of your Wet/Dry Vac.
DOUBLE INSULATED - GROUNDING NOT REQUIRED - WHEN SERVICING USE
ONLY IDENTICAL REPLACEMENT PARTS.
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-DO NOT EXPOSE TO RAIN.
STORE INDOORS.
WARNING:
SERVICING OF DOUBLE-INSULATED WET/DRY VACUUM
WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE
PROVIDED INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED ON A
DOUBLE-INSULATED APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED.
SERVICING A DOUBLE INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND
KNOWLEDGE OF THE SYSTEM, AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE
PERSONNEL. REPLACEMENT PARTS FOR A DOUBLE-INSULATED WET/DRY VACUUM
MUST BE IDENTICAL TO THE PARTS THEY REPLACE. YOUR DOUBLE-INSULATED
WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ AND THE SYMBOL
(SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE APPLIANCE.
• To reduce the risk of electric shock-unplug before cleaning or servicing.
• DO NOT use without filters in place.
CAUTION: TO REDUCE THE RISK OF INJURY FROM MOVING PARTS- UNPLUG BEFORE
SERVICING.
EXTENSION CORDS
When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required A.W.G. wire size. Before using the vacuum cleaner, make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use.
110V-120V
Amps
0-6
7-10
11-12
13-16
25 Feet
7.5 Meters
18
18
16
14
Length of Extension Cord
50 Feet
15.25 Meters
100 Feet
30.5 Meters
A.W.G. Wire Size
16
16
16
12
16
14
14
150 Feet
45.7 Meters
14
12
12
Not recommended
4
PACKAGE CONTENTS
Remove entire contents of carton.
Remove the power head and take out any contents inside the collection tank.
Check each item against the carton contents list.
Carton Content List
Key Description ..………………….... Qty.
A Vac Assembly………………………..
B Hose…………………………….……
C
D
E Caster..…..……………………..........
F
I
J
G
H
K
L
2-in-1 Utility Nozzle…….…….……..
Caster Foot .....................................
Extension Wands..………………….
Floor Brush/Squeegee.……….....…
Crevice Nozzle…………………....…
Reusable Cloth Filter…….....………
Foam Sleeve Filter.......…….…..…..
4 Screws (Bag)……….…..…………
Operator’s Manual………………..…
1
1
4
2
1
4
1
1
1
1
1
1
NOTE: The hose and accessories for this vacuum are 1.25” (3.18 cm) diameter.
5
GENERAL ASSEMBLY INSTRUCTIONS
A Philips head screw driver is required.
WARNING:
DO NOT PLUG IN POWER CORD TO POWER OUTLET. MAKE SURE PLUG
IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC.
UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY
1. Verify that the power cord is disconnected from the outlet. (fig. 1)
2. Undo the latches. (fig. 2)
3. Lift the power head off the collection tank. (fig. 3)
4. Remove the contents from inside the collection tank. Make sure you have all contents as listed
on page 5. (fig. 4)
5. Turn the collection tank upside down and insert the four caster feet into the slots on the
collection tank and tighten with supplied screws. Verify that the casters are mounted correctly.
Do not over-tighten the screws. (fig. 5)
6. For dry vacuum cleaning, install the supplied dust filter. (fig. 6) See page 11 for filter
installation.
7. For wet vacuum cleaning, install the supplied foam filter. (fig. 7) See page 11 for
filter installation.
8. Place the power head back on the collection tank, aligning the top section with the clasps, and
snapping into place by applying downward pressure. (fig. 8)
9. Insert the locking end of the hose into the port of the collection tank and turn to lock in to
place. (fig. 9)
10. Choose the desired accessories and push onto the suction tube. (fig.10)
POLARIZED PLUG
To reduce the risk of electrical shock, this appliance has a polarized plug (with one blade wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system.
6
DRY-VACUUM OPERATION
DRY VACUUMING
WARNING:
BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION,
ENTITLED ‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH
FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE
GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN,
OR GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR
DUST, DO NOT VACUUM TOXIC MATERIALS.
1. Verify that the power cord is disconnected from the outlet. (fig. 1)
2. In order to prepare your vacuum for dry vacuuming, make sure the filter is completely covering
the filter cage against the power head. (fig. 2 & 3)
3. Place the power head section back on the collection tank and secure it in place using the
latches. (fig. 4)
OPERATING INSTRUCTIONS: DRY VACUUMING
4. Insert the locking end of the hose into the vacuum port on the power head and lock in place.
Push the required attachment onto the free end of the hose or extension. (fig. 5)
5. Plug in the power cord into the outlet. (fig. 6)
6. Turn the motor on by pressing the switch to the ‘I’ ON position. (fig. 7)
7. Once you have completed vacuuming, press the switch to the ‘O’ OFF position and unplug the
power cord from the outlet.
DO NOT USE THE DUST FILTER FOR LIQUID VACUUMING.
O = OFF I = ON
7
LIQUID VACUUM OPERATION
LIQUID VACUUM CLEANING
WARNING:
BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION,
ENTITLED ‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH
FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE
GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN,
OR GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR
DUST, DO NOT VACUUM TOXIC MATERIALS.
WARNING:
DO NOT PLUG IN POWER CORD TO POWER OUTLET. MAKE SURE PLUG
IS DISCONNECTED BEFORE CHANGING THE FILTERS.
1. Verify that the power cord is disconnected from the outlet. (fig. 1) Make sure that the collection
tank is clean and free from dust and dirt.
2. Remove reusable cloth filter, then carefully install the foam sleeve filter over the filter cage and
place the power head back on the collection tank. (fig. 2) See filter installing instructions on
page 11.
DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING.
OPERATING INSTRUCTIONS – WET VACUUMING
3. Fit the desired nozzle to the vacuum hose. (fig. 3)
4. Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the outlet.
(fig. 4)
5. Turn the motor on by pressing the switch to the ‘I’ ON position. (fig. 5)
6. After use, empty the collection (fig. 6), clean and dry the inside and outside before storage.
IMPORTANT!
When vacuuming large quantities of liquids, do not immerse the nozzle completely in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity. You will notice an increase in motor speed. When this happens, turn off the machine, disconnect from power supply, and drain the liquid into a suitable receptacle or drain. To continue vacuuming, refit the collection tank with the drain cap. After wet vacuuming, turn the machine off and remove plug from power supply. Empty the collection tank, clean and dry the inside and outside before storage.
REMEMBER!
The foam filter must be removed after wet vacuuming, and a reusable cloth filter must be installed before dry vacuuming again.
8
BLOWING OPERATION
This Wet/Dry Vac has blowing capabilities. To use the blower feature follow the instructions listed.
WARNING:
ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN
CANADA, CSAZ94.3) BEFORE USING BLOWER.
CAUTION:
KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS.
WARNING:
WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT
BE INHALED.
1. Verify that the power cord is disconnected from the outlet.
2. Make sure the collection tank is empty before using as a blower.
3. Remove hose from the vacuum port.
4. Insert the locking end of the hose into the blowing port on the back side of the power head
and lock into position. (fig. 1)
5. Fit the desired extension wand and or nozzle to the vacuum hose. (fig. 2)
6. Ensure the power switch is turned off and plug in the power supply. (fig. 3)
7. Before turning on the vac, firmly hold loose end of the hose. Turn the motor on by pressing the
switch to the ‘I’ position. (fig. 4)
9
CARE AND MAINTENANCE
1. Verify that the power cord is disconnected from the outlet. (fig. 1)
2. Disconnect the hose from the vacuum. (fig. 2)
3. Undo the latches and remove the power head from the collection tank. (fig. 3)
4. Clear all dirt or debris from the collection tank and hose. (fig. 4)
5. Check the hose, attachments, and power cord to verify that they have not been damaged.
IMPORTANT!
Clean or change the cartridge filter regularly for best performance.
ALWAYS USE
DUST FILTER FOR DRY VACUUMING.
If the machine is used without the dust filter, the motor will burn out and the warranty will be voided. Always keep spare dust filters on hand.
NOTICE!
The filters included are made of high quality materials designed to stop small dust particles. The dust filter should be used for dry pick-up only. A dry dust filter is necessary to pick up dust. If the dust filter is wet, it will clog quickly and be difficult to clean. Handle the filter carefully when removing it for cleaning or replacing. Check the filters for tears or small holes. A small hole can let dust pass through and out of the cleaner. Do not use a filter with holes or tears in it; replace it immediately.
WARNING:
ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE
REMOVING THE POWER HEAD FROM COLLECTION TANK.
10
INSTALLING AND CLEANING
REUSABLE CLOTH FILTER
Installing Reusable Cloth Filter
1. Verify that the power cord is disconnected from the outlet.
2. Remove power head and place in upside down position.
3. Slide reusable cloth filter down over the filter cage making sure the whole cage is covered.
(fig.1 & 2)
4. Replace the power head on to the collection tank.
Removing and Cleaning Reusable Cloth Filter
1. With the removed power head in the upside down position, carefully remove the reusable cloth
filter from the filter cage. (fig. 3) Clean the filter by gently tapping or brushing dirt off. Cleaning
should not be done indoors in living areas.
2. Use a mild soap and water solution to wash reusable cloth filter and rinse with clean water. (fig. 4)
3. Allow the wet filter to air dry for 24 hours before installing onto the filter cage.
INSTALLING AND CLEANING
THE FOAM SLEEVE FILTER
Installing Foam Sleeve Filter
1. Verify that the power cord is disconnected from the outlet.
2. Remove power head and place in upside down position. Follow instructions to remove cloth
filter in the section above.
3. Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is
covered. (fig. 1 & 2)
4. Replace the power head onto the collection tank.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve filter.
(fig. 3)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water. (fig. 4)
3. Allow filter to air dry before installing and using again.
11
TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE
TROUBLESHOOTING
Symptom
Vacuum will not operate
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Collection tank full.
Dust comes from motor cover.
1) The dust filter is missing or
damaged.
2) Vacuum has been used
to collect fine dust, such as
drywall dust, fireplace soot,
or ash, without a fine dust
Reduced efficiency and motor/ speed vibration.
filter equipped.
1) There is a blockage in the
nozzle or hose, or the
collection tank inlet. Or dust
filter blocked by fine dust.
Corrective Action
1) Check power supply – cord,
breakers, fuses.
2) Unplug and check the
power cord. If damaged,
have it repaired by a
professional.
3) Empty collection tank.
1) Attach or replace dust filter.
2) Remove the standard cloth
filter and install the
appropriate fine dust
cartridge filter.
1) Check nozzle, hose and
collection tank inlets for
blockage. Take off the filter
and clean it. Or install new
dust filter.
12
EXPLODED
VIEW
13
PARTS LIST
9
10
11
12
13
14
7
8
5
6
3
4
1
2
Key
Description Part Number
Handle
Power Head Assembly
Float
Filter Cage
Collection Tank
Caster Foot Assembly
Floor Brush / Squeegee
Crevice Nozzle
VJ01PF.10.01.X1
VJBAPF.00.00.X1
TVQTZS.06.YZ.W2.00
VI02SR.10.06.02
VJF1PF.20.01.X1
TVQTJC.16.00.X1
V1FBS
V1CT
2-in-1 Utility Nozzle
V1UB
Extension Wands (Set of 2) V1EW
Hose
Foam Sleeve Filter
Reusable Cloth Filter
Operator's Manual
V1H6
VFF51
VRC5
1
1
1
1
1
1
1
4
1
Qty
Included with Vac
1
1
1
1
1
14
Advertisement