Wall Mount Installation Instructions
0˚ Down 30˚ Down 30˚Up 0˚ Up
Thank you for buying RAB lighting fixtures. Our aim is to design the best quality products so you can get the job done right.
We’d like to hear your comments. Call us at 888-RAB-1000, attention Marketing Department or email: [email protected].
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and and all applicable local codes. Proper grounding is required for safety.
WARNING:
MAKE CERTAIN POWER IS OFF BEFORE INSTALLING OR MAINTAINING FIXTURE
LOCATION
Fixture should not be recessed.
WIRING
All units are factory wired for 120v. If voltages other than 120V are required, Remove the reflector and rewire for the appropriate voltage.
1. Connect the appropriate BLACK fixture lead to the
(+) LINE supply lead.
2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
3. Fixture ground wire must be connected to supply ground.
4. All unused leads must be capped and insulated.
(+) LINE BLACK
(–) COMMON WHITE LIGHT
FIXTURE
GROUND GROUND
LAMP INSTALLATION
Caution: Prior to installing, check that the lamp is of proper type and wattage. Observe lamp manufacturer’s recommendations on lamp operation, ballast type and burning positions.
1. Disconnect power. Make sure fixture and lamp are cool enough to touch.
2. Open fixture by removing the 4 door screws. Swing lens door down on hinges.
3. Insert lamp.
4. Before closing lens door make sure frame gasket is properly seated all around fixture.
5. Close door. Tighten 4 screws.
REPLACEMENT LAMPS:
High Pressure Sodium
Wattage
70
100
150
Catalog #
LHPS70
LHPS100
LHPS175
ANSI Metal Halide
Code Wattage
S62 50
S54
S55
70
Catalog #
LMH50
LMH70
ANSI Fluorescent
Code
M110
M98
100 LMH100 M90
Wattage Catalog #
42 LCFL42
150 LMH150PS M102
150 LMH150 M107
175 LMH175 M57
CLEANING
Clean reflector and glass refractor with nonabrasive glass cleaning solution or detergent. Rinse with clean water.
Caution: Be sure fixture temperature is cool enough to touch.
TROUBLESHOOTING CHECKLIST:
1. Proper lamp is installed. Lamp is not faulty.
2. Fixture is wired properly.
3. Line voltage at the fixture is proper.
4. Fixture is grounded properly.
RAB LIGHTING Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com
BEAM SPREAD ADJUSTMENT
WARNING: Make certain power is off. The lamp socket can be moved from the standard wide beam position (position 2) to the rear position to provide a more narrow beam.
Reflector screws (4)
1
Narrow
2
Standard
(Factory Setting)
Reflector
Loosen these
2 screws to slide socket
To adjust socket position, remove the reflector screws and carefully lift the reflector out of the fixture. Loosen the two socket screws and slide socket into the desired position. Tighten screws. Replace the socket bracket and reflector.
WALL MOUNTING OPTIONS
0˚ Down Position
No changes required
30˚ Down Position
Follow
1-2-3
30˚Up Position
Follow both
1-2-3 &
A,B,C below
1. Open the lens frame & remove the 4 screws securing the reflector. Remove the reflector.
2. Remove the 2 bolts securing the wall mount to the fixture.
3. Rotate the wall mount 180 ˚ and re-attach the mounting bolts & lockwashers. Replace the reflector.
Wall Mount Bolts
& Lockwashers
For Hands
Free Wiring:
Hook the inner bracket hook into the outer bracket slot for easy hands free wiring
Hook
0˚ Up Position
Outer Bracket
Inner Bracket
Rubber Plugs
A. Remove the 4 screws securing the inner bracket to the wall mount.
B. Rotate the inner bracket 180 ˚ and re-attach the screws & lockwashers.
C. Remove the rubber plugs from the bottom of the wall mount and re-insert them into the screw holes at the top of the wall mount.
MOUNTING TO A WEATHERPROOF BOX
The outer bracket has multiple mounting holes to fit most weatherproof boxes. (recessed only)
1. Attach the outer bracket to the weatherproof box and secure it to the inner bracket with the 2 lock screws on the bottom of the fixed wall mount.
2. For additional strength, the outer bracket can be anchored to the wall by using the outer holes on the bracket.
Outer Bracket
Outer Bracket
Mounting Screws
Rubber Plugs
Outer Bracket
Lock Screws
Inner Bracket
Inner Bracket
Attachment
Screws
Slot
Back View of
Wall Mount
Outer Bracket
Lock Screws
© RAB LIGHTING,9541-06/04
EASY INSTALLATION & PRODUCT HELP
Fax Back
Faxed Tips & Specs,
24 hours/day.
888 RAB-1236
Tech Help Line www.rabweb.com
Call our friendly experts. Visit our internet site for
8AM - 5PM ET Mon. - Fri.
888 RAB-1000 [email protected]
color product photos and installation tips.
RAB LIGHTING
170 Ludlow Avenue Northvale, New Jersey 07647 U.S.A.
Your questions and requests will be answered promptly.
RA
B
EASY!
THESE INSTRUCTIONS DO
NOT COVER ALL DETAILS
OR VARIATIONS IN
EQUIPMENT NOR DO THEY
PROVIDE FOR EVERY
POSSIBLE CONTINGENCY
TO BE MET IN
CONNECTION WITH
INSTALLATION, OPERATION
OR MAINTENANCE.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement