Generac 20kW RD02023JDAS Standby Generator Manual
Advertisement
Advertisement
B
173
[6.8]
146
[5.8]
RADIATOR/EXHAUST
DISCHARGE AIR
4
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
TOP VIEW
758 [29.8]
DOOR TYP
843 [33.2]
CENTER OF
GRAVITY
AIR INTAKE
(BOTH SIDES)
BATTERY 12 VOLT
NEGATIVE GROUND
3
SERVICE ITEM
OIL FILL CAP
OIL DIP STICK
OIL FILTER
OIL DRAIN HOSE
RADIATOR DRAIN HOSE
AIR CLEANER ELEMENT
2.4L
RIGHT SIDE
RIGHT SIDE
RIGHT SIDE
RIGHT SIDE
LEFT SIDE
LEFT SIDE
MUFFLER
FAN BELT
FRONT
EITHER SIDE
BATTERY LEFT SIDE
REFERENCE OWNERS MANUAL FOR PERIODIC
REPLACEMENT PART LISTINGS.
SH 1/2 REV B WINDCHILL VERSION B.1
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN 766 [1689]
WITH WOODEN SHIPPING SKID 802 [1769]
1
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
OIL DRAIN: 3/8" NPT
EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O.
9. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
VISE ACTION LATCH,
ONE PER DOOR, ONE LIFT-OFF
DOOR PER SIDE OF GENERATOR
REAR ENCLOSURE COVER
PANEL
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
CUSTOMER ACCESS
ASSEMBLY, CONTROL PANEL
ACCESS, BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
1407 [55.4]
OVERALL
HEIGHT
LIFTING PROVISIONS
(4 PLACES)
SEE NOTE 9 AND
CENTER OF GRAVITY
DIMENSIONS
A
EXHAUST MUFFLER ENCLOSED WITHIN
GENERATOR ENCLOSURE
LEFT SIDE VIEW
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
4
REAR TANK COVER
SEE NOTE 4
3
888 [35.0]
OVERALL WIDTH
REAR VIEW
B
302 [11.9]
182
[7.2]
1322 [52.0]
1954 [76.9] OVERALL LENGTH
RIGHT SIDE VIEW
TITLE
INSTALL CPL PROTO D2.4L SW
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
2
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
ISSUE DATE:
SIZE
B
SCALE
CAGE NO DWG NO 0K7002AY17
0.050
WT-KG SEE ABOVE SHEET
1
REV
B
1 of 2
A
B
A
4
757 [29.8]
TYP
621 [24.5]
TYP
267 [10.5]
TYP
181 [7.1]
TYP
REMOVABLE COVER
112 [4.4]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
4
1194 [47.0]
1044 [41.1]
FUEL SUPPLY
FUEL RETURN
828 [32.6]
923 [36.4]
1429 [56.2]
1554 [61.2]
1764 [69.4]
712 [28.0]
1242 [48.9]
1842 [72.5]
3
SH 2/2 REV B WINDCHILL VERSION B.1
FUEL FILL
(2" NPT FEMALE)
FUEL LEVEL
GAUGE/SENDER
INNER TANK NORMAL VENT
(2" NPT FEMALE)
INNER TANK EMERGENCY VENT
(2" NPT FEMALE)
FUEL TANK
TOTAL CAPACITY 253.6 [67]
USABLE CAPACITY 230.9 [61]
CAPACITY: LITER [GALLONS]
DIMENSIONS: MM [INCH]
3
1
112 [4.4]
187 [7.3]
STUB-UP
AREA
HIGH AND LOW VOLTAGE
STUB-UP AREA
CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER
CONNECTION OPENING
786 [30.9]
STUB-UP
AREA
38
[1.5]
125
[4.9]
51
[2.0]
B
REMOVABLE
STUB-UP COVER
353
[13.9]
16.7 [.66]
MOUNTING HOLES
(8 PLACES)
19
[.7]
851 [33.5]
TYP
888
[35.0]
TITLE
INSTALL CPL PROTO D2.4L SW
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
2
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
ISSUE DATE:
SIZE
B
SCALE
CAGE NO DWG NO 0K7002AY17
0.075
WT-KG SEE ABOVE SHEET
1
REV
B
2 of 2
A

Download
Advertisement