Generac 20kW RD02023JDAS Standby Generator Manual

Add to My manuals
2 Pages

advertisement

Generac 20kW RD02023JDAS Standby Generator Manual | Manualzz

B

173

[6.8]

146

[5.8]

RADIATOR/EXHAUST

DISCHARGE AIR

4

RADIATOR/EXHAUST

DISCHARGE AIR

(BOTH SIDES)

REMOVE COVER

FOR ACCESS TO

RADIATOR FILL CAP

TOP VIEW

758 [29.8]

DOOR TYP

843 [33.2]

CENTER OF

GRAVITY

AIR INTAKE

(BOTH SIDES)

BATTERY 12 VOLT

NEGATIVE GROUND

3

SERVICE ITEM

OIL FILL CAP

OIL DIP STICK

OIL FILTER

OIL DRAIN HOSE

RADIATOR DRAIN HOSE

AIR CLEANER ELEMENT

2.4L

RIGHT SIDE

RIGHT SIDE

RIGHT SIDE

RIGHT SIDE

LEFT SIDE

LEFT SIDE

MUFFLER

FAN BELT

FRONT

EITHER SIDE

BATTERY LEFT SIDE

REFERENCE OWNERS MANUAL FOR PERIODIC

REPLACEMENT PART LISTINGS.

SH 1/2 REV B WINDCHILL VERSION B.1

WEIGHT DATA WITH EMPTY BASETANK

(SEE NOTE 5)

GENERATOR AS SHOWN 766 [1689]

WITH WOODEN SHIPPING SKID 802 [1769]

1

NOTES:

1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG.

REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT

FOR CONCRETE PAD GUIDELINES

2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE

AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT

APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,

STATE, AND LOCAL CODES.

3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:

- SEE SPECIFICATION SHEET OR OWNERS MANUAL

- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF

GENERATOR

4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS

THE STUB-UP AREAS AS FOLLOWS:

- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION

NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.

- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES

5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.

6. ENGINE SERVICE CONNECTIONS

OIL DRAIN: 3/8" NPT

EXHAUST OUTLET: 2" O.D.

7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND

AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.

8. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 35 INCHES H2O.

9. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.

10. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5

(USE STANDARD SAE TORQUE SPECS)

VISE ACTION LATCH,

ONE PER DOOR, ONE LIFT-OFF

DOOR PER SIDE OF GENERATOR

REAR ENCLOSURE COVER

PANEL

SEE NOTE 4

CIRCUIT BREAKER

SEE NOTE 3

CUSTOMER ACCESS

ASSEMBLY, CONTROL PANEL

ACCESS, BATTERY CHARGER

LOCATED WITHIN

SEE NOTE 4

1407 [55.4]

OVERALL

HEIGHT

LIFTING PROVISIONS

(4 PLACES)

SEE NOTE 9 AND

CENTER OF GRAVITY

DIMENSIONS

A

EXHAUST MUFFLER ENCLOSED WITHIN

GENERATOR ENCLOSURE

LEFT SIDE VIEW

DRAWING CREATED FROM PRO/ENGINEER

3D FILE. ECO MODIFICATION TO BE

APPLIED TO SOLID MODEL ONLY.

4

REAR TANK COVER

SEE NOTE 4

3

888 [35.0]

OVERALL WIDTH

REAR VIEW

B

302 [11.9]

182

[7.2]

1322 [52.0]

1954 [76.9] OVERALL LENGTH

RIGHT SIDE VIEW

TITLE

INSTALL CPL PROTO D2.4L SW

GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING

WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR

ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT

THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.

c GENERAC POWER SYSTEMS 2013

2

ELECTRONICALLY APPROVED

INSIDE WINDCHILL

ISSUE DATE:

SIZE

B

SCALE

CAGE NO DWG NO 0K7002AY17

0.050

WT-KG SEE ABOVE SHEET

1

REV

B

1 of 2

A

B

A

4

757 [29.8]

TYP

621 [24.5]

TYP

267 [10.5]

TYP

181 [7.1]

TYP

REMOVABLE COVER

112 [4.4]

DRAWING CREATED FROM PRO/ENGINEER

3D FILE. ECO MODIFICATION TO BE

APPLIED TO SOLID MODEL ONLY.

4

1194 [47.0]

1044 [41.1]

FUEL SUPPLY

FUEL RETURN

828 [32.6]

923 [36.4]

1429 [56.2]

1554 [61.2]

1764 [69.4]

712 [28.0]

1242 [48.9]

1842 [72.5]

3

SH 2/2 REV B WINDCHILL VERSION B.1

FUEL FILL

(2" NPT FEMALE)

FUEL LEVEL

GAUGE/SENDER

INNER TANK NORMAL VENT

(2" NPT FEMALE)

INNER TANK EMERGENCY VENT

(2" NPT FEMALE)

FUEL TANK

TOTAL CAPACITY 253.6 [67]

USABLE CAPACITY 230.9 [61]

CAPACITY: LITER [GALLONS]

DIMENSIONS: MM [INCH]

3

1

112 [4.4]

187 [7.3]

STUB-UP

AREA

HIGH AND LOW VOLTAGE

STUB-UP AREA

CIRCUIT BREAKER,

NEUTRAL AND CUSTOMER

CONNECTION OPENING

786 [30.9]

STUB-UP

AREA

38

[1.5]

125

[4.9]

51

[2.0]

B

REMOVABLE

STUB-UP COVER

353

[13.9]

16.7 [.66]

MOUNTING HOLES

(8 PLACES)

19

[.7]

851 [33.5]

TYP

888

[35.0]

TITLE

INSTALL CPL PROTO D2.4L SW

GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING

WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR

ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT

THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.

c GENERAC POWER SYSTEMS 2013

2

ELECTRONICALLY APPROVED

INSIDE WINDCHILL

ISSUE DATE:

SIZE

B

SCALE

CAGE NO DWG NO 0K7002AY17

0.075

WT-KG SEE ABOVE SHEET

1

REV

B

2 of 2

A

advertisement