Frigidaire WSA2BF, WSA2BE, FSA1BD, HSA1QE, HSA1QD, HSA1BD, WSA2BD, ESA1BF, CSA1BF, CSA1BD Product information

Frigidaire WSA2BF, WSA2BE, FSA1BD, HSA1QE, HSA1QD, HSA1BD, WSA2BD, ESA1BF, CSA1BF, CSA1BD Product information
C
HPS
CC - Contactor Coil
CCH - Crankcase Heater
HPS - High Pressure Switch
24 VOLT FIELD
CONNECTIONS
F
LEGEND:
ASCT
ASCT
(SEE NOTE 7)
C OUTDOOR FAN
MOTOR
FIELD WIRING
LOW VOLTAGE
HIGH VOLTAGE
CC
R
S
COMPRESSOR
BLACK
T1
T3
T2
SEE NOTE 6
YELLOW
HPS
ASCT
(SEE
NOTE 7)
BLACK
BLUE
Single Phase
S
GROUNDING
SCREW
L1 L2 GND
7/19
710388C
(Replaces 710388B)
RED
C
R
BLACK
CONTACTOR
CRANKCASE
HEATER
(OPTIONAL)
BLACK
1. Disconnect all power before servicing.
1. Couper le courant avant de faire letretien.
2. For supply connections use copper conductors only.
2. Employez uniquement des conducteurs en cuivre.
3. Not suitable on systems that exceed 150 volts to ground.
3. Ne convient pas aux installations de plus de 150 volt a la terre.
4. For replacement wires use conductors suitable for 105 deg C.
5. For ampacities and overcurrent protection, see unit rating plate.
6. Connect to 24 vac/40ca/class 2 circuit. See furnace/airhandler installation
R
instructions for control circuit and optional relay/transformer kits.
7. Anti-Short Cycle Timer (ASCT) may or may not be installed in the unit. If desired,
BLACK
C
START
ASCT is factory installed on select models only or may be field installed as shown using
RELAY
manufacturer’s approved kit. If not present, connect Yellow and Black wires per Note 6.
S
OUTDOOR
2
FAN MOTOR
3
208/230V
F
1
L2
L1
C
CCH
DUAL
COMPRESSOR
(OPTIONAL)
CAPACITOR
CONTACTS
H
YELLOW
T2
T1
START
R
CAPAC
YELLOW/BLACK
T1 T2
C
L1 L2
S
H
BLACK
NOTES:
ORANGE
Split System Air Conditioner (Outdoor Section)
WIRING DIAGRAM
YELLOW