Tappan FS4BF-KB/C, PSA1BF, PSA4BF-KB/C, PSA4BF-KA/B, PSA4BF, FS4BF, FSA1BF, FS4BF-K(A,B) Product information

WIRING DIAGRAM Two Stage Split System Air Conditioner (Outdoor Section) 208/230V With ECM Outdoor Motor Status LED Description Status LED NOTES: 1. Disconnect all power before servicing. 2. For supply connections use copper conductors only. 3. Not suitable on systems that exceed 150 volts to ground. 4. For replacement wires use conductors suitable for 105 °C 5. For ampacities and overcurrent protection, see unit rating plate. 6. Connect to 24 vac/40va/class 2 circuit. See furnace/airhandler installation instructions for control circuit and optional relay/transformer kits. 7. Couper le courant avant de faire letretien. 8. Employez uniquement des conducteurs en cuivre. 9. Ne convient pas aux installations de plus de 150 volt a la terre. Single Phase / 60 Hz. Lockout Level N/A N/A Normal Run; Solid Green Normal Operation, no trip Long Run Time. Compressor running extremely long run cycle. (disabled in HP mode.) Code 1; Yellow Flash 1 Lockout Indication N/A N/A Code 2; Yellow Flash 2 Comprsesor Pressure Trip. Disch. or suct. pressure out of limits or compressor overloaded. 4 cons, 10x total Red: Flash 2 Code 3; Yellow Flash 3 Short Cycling. Compressor is running only briefly. 4 cons, 10x total Red: Flash 3 Code 4; Yellow Flash 4 Locked Rotor. Compressor Moderate Run. Compressor runs >15min, then trips >7min. Open Start Circuit. Current only in run circuit. 10 consecutive Red: Flash 4 4 cons, 10x total Red: Flash 5 1 Occurrence Red: Flash 6 Code 7; Red Flash 7 Open Start Circuit. Current only in start circuit. 1 Occurrence Code 8; Yellow Flash 8 Welded Contactor. Compressor always runs. N/A N/A Code 9; Yellow Flash 9 Low Voltage. Control circuit <17 VAC. N/A N/A Code 10; Red Flash 10 Over Current Protection. PROT terminal has >2A input for more than 40ms 1 Occurrence Red: Flash 10 Code 5; Yellow Flash 5 Code 6; Red Flash 6 Red: Flash 7 ROUTE THIS WIRE THROUGH “C” OPENING IN CORESENSE MODULE BLACK 208/230V H C CAPACITOR RED L1 COMPRESSOR L2 ROUTE THIS WIRE THROUGH “S” OPENING IN CORESENSE MODULE L1 YELLOW BLACK C CCH ECM OUTDOOR FAN MOTOR S L2 Y2 Y1 C CCH COMPRESSOR CONTACTS BLACK CONTACTOR R YELLOW ROUTE THIS WIRE THROUGH “R” OPENING IN CORESENSE MODULE COMPRESSOR OUTDOOR FAN MOTOR R T1 T2 C ECM C H CORESENSE MODULE S HPS LPS Y2 CC Y Y2 C L1 L2 LEFT RIGHT BLUE BROWN L1 L2 T2 YELLOW Y1 CAPACITOR T1 BLACK WHITE Y L CORESENSE COMPRESSOR SOLENOID COIL CSC GRN R DC P C R L Y Y2 SOL L1 L2 SINGLE PHASE FIELD SUPPLY C P GRAY DC SOL YELLOW YELLOW RED BLACK BLUE C R Y2 24 VOLT FIELD CONNECTIONS YELLOW/ BLACK HIGH PRESSURE SWITCH YELLOW/ BLACK YELLOW YELLOW LOW PRESSURE SWITCH LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE CC- CONTACTOR COIL CCH - CRANKCASE HEATER LPS - LOW PRESSURE SWITCH HPS - HIGH PRESSURE SWITCH CSC - COMPRESSOR SOLENOID COIL Y2 R C TO THERMOSTAT Y 7112090 10/13
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement