Tappan FSH1BF, PSH1BF Product information

Tappan FSH1BF, PSH1BF Product information
WIRING DIAGRAM
208/230V
Two Stage Split System Heat Pump (Outdoor Section) With Coresense and ECM Fan Motor
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground.
4. For replacement wires use conductors suitable for 105 °C
5. For ampacities and overcurrent protection, see unit rating plate.
6. Connect to 24 vac/40va/class 2 circuit. See furnace/airhandler installation
instructions for control circuit and optional relay/transformer kits.
1. Couper le courant avant
de faire letretien.
2. Employez uniquement des
conducteurs en cuivre.
3. Ne convient pas aux installations
de plus de 150 volt a la terre.
G
TO UNIT
GROUND LUG
L1
ECM
ECM
L2
L2
C
Y1
L2
RED
YELLOW
BLACK
BLUE
COMPRESSOR
LEFT
CONTACTOR
GREEN
G
T1
T2
L1
L2
S
TO UNIT
GROUND LUG
RIGHT
L1
C
BROWN
Y2
OUTDOOR
FAN MOTOR
R
T1
CAPACITOR
H
GROUNDING
SCREW
CCH
R
C
Y1
Y2
C
H
CCH
L1
YELLOW
C
BLACK
YELLOW
OUTDOOR
FAN MOTOR
208/230V
Single Phase / 60 Hz.
C
S
GRND L1 L2
BLACK
T2
BLUE
COMPRESSOR
BLACK
WHITE
BLACK
AMB SENSOR
DEFROST CONTROL
BOARD
COIL SENSOR
AMB
SENSOR
OUTDOOR
FAN1 FAN2 CCH2 CCH1
TEMP
SOL
P
C
R
L
Y1
Y2
COIL#1
TEMP
HOT1
HOT2
(24V COM)
Y1 OUT
Y2 OUT LPS
COIL#1
TEMP
HOT1
HOT2
(24V COM)
Y1 OUT
Y2 OUT LPS
Y1 IN
R
O
C W2 IN
P
DC SOL
HPS
RVS
HP2 HP1 LP2 LP1 W2 OUT
Y1 IN
R
O
C W2 IN
RV2 RV1
Y2 IN
L
RV2 RV1
Y2 IN
ODT
BLACK
LEGEND:
TO THERMOSTAT
BLACK
RED
AMV- Ambient Sensor
CC- Contactor Coil
CCH- Crankcase Heater
CSC- Compressor
Solenoid Coil
LPS- Low Pressure Switch
HPS- High Pressure Switch
HGBP- Hot Gas By Pass
Valve
RVS- Reversing Valve
Solenoid
*OUTDOOR THERMOSTAT
(OPTIONAL)
L
CORESENSE
MODULE
FIELD WIRING
LOW VOLTAGE
HIGH VOLTAGE
R
C
RVS
HP2 HP1 LP2 LP1 W2 OUT
L
BLACK
HPS
DC
HGBP
Y1
RED
HGBP
Y2
OUTDOOR
FAN1 FAN2 CCH2 CCH1
TEMP
DEFROST CONTROL
BOARD
CSC
BLACK
CORESENSE
MODULE
BLACK
COIL
SENSOR
BLACK
BLACK
CC
(OPTIONAL OUTDOOR
THERMOSTAT)
TO THERMOSTAT
ODT
(OPTIONAL
OUTDOOR
THERMOSTAT)
1010407C
(Replaces 1010407B)
07/19