Maytag SA2BD-KA, SA4BD-KA Product information

Maytag SA2BD-KA, SA4BD-KA Product information
WIRING DIAGRAM
Split System Air Conditioner (Outdoor Section)
Single Phase
NOTES:
1.
2.
3.
4.
5.
6.
1. Couper le courant avant de faire letretien.
Disconnect all power before servicing.
2. Employez uniquement des conducteurs en cuivre.
For supply connections use copper conductors only.
3. Ne convient pas aux installations de plus de 150 volt a la terre.
Not suitable on systems that exceed 150 volts to ground.
R
For replacement wires use conductors suitable for 105° C.
Orange
For ampacities and overcurrent protection, see unit rating plate.
Black
C
Connect to 24 vac/40va/class 2 circuit. See furnace/air handler installation
S
Blue
instructions for control circuit and optional relay/transformer kits.
Outdoor
Fan Motor
Red
208/230V
L2
Black
Yellow
F
CCH (Optional)
Compressor
Contacts
R
T1
Yellow
Start
Relay
Yellow
H
T1
T2
L1
L2
S Compressor
Black
LPS
(If equipped)
C
Dual Capacitor
R Outdoor
Fan Motor
CC - Contactor Coil
CCH - Crankcase Heater
LPS - Low Pressure Switch
HPS-High Pressure Switch
(If equipped) HPS
Field Wiring
Factory Wiring:
Low Voltage
High Voltage
R
Grounding
Screw
C
LPS
(If equipped)
Legend
Yellow or
Yellow Black
Yellow with
Black Hash
See
Note 6.
Black or
Black White
HPS
(If equipped)
CC
24 Volt Field
Connections
Start
Capacitor
S
F
Red or Red Black
C
2
3
1
C
Dual
Capacitor H
T2
C
Contactor
L1
S
Crankcase
Heater
(Optional)
Compressor
¢710537+¤
L1 L2 Grd
(1 Phase)
Field Supply
710537B
(REPLACES 710537A)
1208
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project