Maytag PDF2SF-A is a feature-rich electric dryer that is designed to make your laundry routine easier and more efficient. With its large capacity, you can dry large loads of laundry quickly and easily. The Maytag PDF2SF-A also features a variety of cycles and options to choose from, so you can customize the drying process to meet your specific needs.
Some of the key features of the Maytag PDF2SF-A include:
- Large capacity: The Maytag PDF2SF-A has a large capacity of 7.0 cubic feet, which means you can dry large loads of laundry quickly and easily.
- Variety of cycles and options: The Maytag PDF2SF-A features a variety of cycles and options to choose from, so you can customize the drying process to meet your specific needs. Some of the available cycles include:
Advertisement
Advertisement
WIRING DIAGRAM
Dual Fuel Heating and Cooling Packaged System
NOTES:
1. Disconnect power before servicing.
208/230 Volt
5. For supply wire ampacities and overcurrent protection, see unit rating plate.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
4. If any of the original wire as supplied with the furnace must be replaced, it must
be replaced with wiring material having a temperature rating of at least 105°C.
6. Ensure that wires from the blower remain connected to the board thermostat terminals after
making the field thermostat connections.
7. A heat pump thermostat with fossil fuel back-up heat capability is REQUIRED for this system.
YELLOW
BLACK
BLACK
TO 208/230 VAC
POWER SUPPLY
R
C
S
CONTACTOR
CCH
IF
EQUIPPED
BLACK/WHITE
YELLOW/BLACK
RED
T2 T1
BLACK
L2 L1
ORANGE
R
BLUE
OUTDOOR
FAN MOTOR
BLACK
C
S
HIGH TEMP LIMIT
SWITCH
HPS
VIOLET
BLACK
FLAME SENSOR
BLUE
BLACK
BLACK
FLAME ROLL-OUT
SWITCH
LPS
BLUE
ORANGE
BROWN
AMBIENT
SENSOR
COIL
SENSOR
PRIMARY
GAS VALVE
HI LO C
YELLOW
BROWN
GREEN
Single Phase / 60 Hz.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V a la terre.
AMBIENT
COND FAN
AMBG
M
PRESS
DEMAND
DEFROST CONTROL
COILG BOARD
SW
REV
COIL
W2 W2
TEST
L R C Y O IN OUT
VALVE
YELLOW
YELLOW
BLACK
BLACK
REV. VALVE
SOLENOID
YELLOW
LOW
PRESSURE
SWITCH
YELLOW
YELLOW
YELLOW
HIGH
PRESSURE
SWITCH
YELLOW
TERM.
STRIP
Y1
O
E
Y2
R
W1
L
C
G
W2
YELLOW
ORANGE
BLUE
RED
WHITE
BLACK
GREEN
BROWN
Y2
Y
L
R
C
DC
SOL
COMFORT
ALERT
C
R
S
COMPRESSOR
VARIABLE
SPEED
BLOWER
MOTOR
5 4 3 2 1
5 4 3 2 1
H C F
DUAL CAPACITOR
8
9
8
9
10
11
10
11
12
13
12
13
14
15
14
15
16 16
6
7
4
5
1
2
3
6
7
4
5
1
2
3
BLUE
RED
1
INDUCER
MOTOR
2
3
RED
WHITE
IGNITOR
BROWN
BROWN
240V
208V
TRANSFORMER
COM
BLACK
DEFROST BOARD OPERATION:
-- Heat Pump operates in heating mode until the combination of outdoor ambient
and outdoor coil temperatures initiate a defrost cycle. The outdoor coil
temperature must be at or below 32˚F before the defrost cycle begins.
-- There must be a minimum of 20 minutes between defrost cycles. After this
time, temperature conditions must call for defrost continuously for 4 1/2
minutes before a defrost cycle is initiated.
-- The defrost cycle ends when either the outdoor coil temperature sensor reaches
the defrost terminate set point, or 13 minutes, 39 seconds of compressor run time
has elasped with the control in the defrost mode. (See installation instructions for
available terminate temperatures and their specific jumper location)
1
2
3
YELLOW
24V
BLACK
RED
WHITE
BROWN
BROWN
RED
RED
BLACK
WHITE
WHITE
LO-HEAT
HI-HEAT
PARK2
PARK1
COOL
EAC
CONT
XMFR
LINE
HUM
P2
1
5 NEUTRALS
5A FUSE
RED
HEAT
A B C D
SYSTEM STATUS - 2nd STAGE HEAT DEMAND
No demand for 2nd stage heat
2nd stage heat demand (Normal operation)
2nd stage heat demand, high pressure switch not closed
COOL
A B C D
ADJUST
IGNITION / BLOWER
CONTROL BOARD
AUTO
HEAT STAGE
(HIGH HEAT
DEMAND)
GREEN
10 5 NONE
(CFM)
YEL
GREEN
HI/LO
DEHUMIDIFY
(STATUS)
RED
LEGEND:
FIELD WIRING
LOW VOLTAGE
HIGH VOLTAGE
LED STATUS (GREEN)
OFF
ON
Flashing
SYSTEM STATUS - HI/LO DEHUMIDIFY (Cooling Mode only)
Factory jumper wire “R” to “DEHUM” in place or
“Close on Fall” humidistat (Low humidity) - Closed
Humidistat open (High Humidity) Low Speed Blower call
LED STATUS (GREEN)
ON
OFF
P6
16-PIN
DEHUM
0
Y2
Y
G
R
C
W2
W1
ORANGE
BLUE
YELLOW
GREEN
RED
BLACK
BROWN
WHITE
SYSTEM STATUS - IGNITION
Power On (Normal Operation)
High Limit Circuit Open
Pressure Switch Open with Inducer On
Pressure Switch Closed with Inducer Off
Failed Ignition (5 attemps) - Control in 1 Hour Lockout
208-230 Volt Polarity Issue
Excess High limit trips (5) within one call for heat
Excess pressure switch cycles (5) within one call for heat
Excess flame dropouts (5) within one call for heat
Not Used
Flame present with gas valve Off
LED STATUS (RED)
ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
SYSTEM STATUS - CFM
NOT USED
LED STATUS (YELLOW)
OFF
711138A
(Replaces 711380)
05/11