- Home
- Domestic appliances
- Small kitchen appliances
- Coffee makers
- Electrolux
- E24CM75GSSA
- Installation Guide
advertisement
Installation Instructions
Built-In Coffee Maker
E24CM75GSS
Electrolux I ic o N
TM
E24CM76GSS 102221 REV.C-2
2
Before You Begin
READ THESE INSTRUCTIONS
[] [] I m [] [] [] i [] [] [] [] [] [] [] [] [] [] [] [] [] []
NOTE
Installer: Leave these instructions with the owner.
Owner: Read your Coffee Maker Use and Care Guide completely before use.
It contains important safety information for operating this appliance. It also has many suggestions for getting the best results from your coffee maker.
Read all instructions before installing the coffee maker.
For your safety, please read and observe all safety instructions.
This guide will help you anticipate electrical and water connections and help you select the best location for the coffee maker.
i XWARNING
Tip Over Hazard: Do not use coffee maker until completely installed.
Do not connect this appliance to electrical power until it is completely installed.
QUESTIONS?
[] [] [] ii [] [] [] [] [] I!
[] [] [] [] [] !1
1-877-4Electrolux
For toll-free
(1-877-435-3287) telephone support in the U.S. and Canada.
[] [] [] [] [] []
INTERNET
[] [] [] I [] m [] [] [] I I I [] m [] [] [] [] [] [] []
For online support and product information:
In the U.S. visit www.electroluxusa.com.
In Canada, visit www.electroluxca.com.
[]
© 2007 Electrolux Home Products, lnc,
Post Office Box 212378, Augusta, Georgia 30917, USA
All rights reserved.
Finding Information
3
[]
TABLE OF CONTENTS
[] [] [] [] [] [] [] [] [] []
[] [] [] [] [] [] [] [] il [] []
Finding Information ...............................................
Important Safety Instructions ........... 4
Preparing for Installation ......................................
Planning the Location ........................... 7
Before You Start ..................................10
Tools Needed for Installation ...........11
Plumbing Installation ..........................1 2
Installing the Cabinet Glides ............ 14
Installing the Unit in the Cabinet., 16
Coffee Maker Removal ......................16
Connecting the Plumbing .................17
Verifying Operation ............................18
IF YOUR UNIT REQUIRESSERVICE...
[] [] [] [] [] [] [] [] [] [] [] II [] Ill [] []
[] [] [] [] []
[]
IMPORTANT:If the unit requires service, be sure to have the model and serial number available when you call. The model and serial number are on the data plate located inside the brewing unit door. See the use and care guide for instructions on how to open the front panel and brewing unit doors.
4
Safety
IMPORTANT SAFETY INSTRUCTIONS
[] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] []
Safety Preca utions
Do not attempt to install or operate this appliance until you read the safety precautions in this guide. Safety items throughout this guide are labeled with a
Warning or Caution based on the risk type.
Definitions
j_
This symbol is the safety alert symbol.
It is used to alert you to potential possible injury or death.
/_WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
AxCAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
IMPORTANT
Indicates installation, operation or maintenance information which is important but not hazard related.
/_WARNING
Electrolux cannot be held responsible for damage to property or injury to persons caused by failure to comply with the installation, maintenance and safety instructions contained in this handbook
Safety
5
,,&WARNING
To reduce the risk of fire, electrical shock, or injury when using your coffee maker, follow basic safety precautions including the following:
Read all instructions before operating the coffee maker.
IMPORTANT: Before performing any type of service or installation, make sure that electric power to the coffee maker is disconnected.
IMPORTANT: To avoid the possibility of explosion or fire, do not store or use combustible, flammable, or explosive liquids or vapors (such as gasoline) inside or in the vicinity of this or any other appliance.
IMPORTANT: This appliance is equipped with a three-prong grounding plug for protection against possible electric shock hazards.
Plug it only into a dedicated, grounded electrical outlet.
When only a standard two-prong electrical outlet is available, the customer must have it replaced with a dedicated, properly grounded three-prong electrical outlet before using this appliance.
Do not under any circumstances, cut or remove the third
(ground) prong from the power cord. Do not use an adapter plug. Do not use an extension cord.
Do not use a power cord that is frayed or damaged.
The use of a ground fault interrupter (GFI) is not recommended.
• Do not install or use a damaged appliance.
If you receive a damaged appliance, immediately contact your dealer or builder.
• Do not use the coffee maker until it has been properly installed by a qualified installer according to these installation instructions.
The installer must show the customer the location of the power plug so that they know where and how to disconnect power to the coffee maker.
° Do not install, repair, or replace any part of the coffee maker unless specifically recommended in the literature accompanying service technician should perform all other service.
it. A qualified
• Keep packaging materials away from children.
Plastic sheets and bags can cause suffocation.
Save These Instructions for Future Reference.
6
Safety
General Safety Precautions (continued)
,'&WARNING
e
Do not tamper with the controls.
Clean the coffee maker thoroughly according to the Flushing
Out the
Coffee Maker
section in the use and care guide before operating it for the first time.
• When installing or cleaning the mechanical parts of the coffee maker, exercise care with hands and arms around the metal edges.
• Many metal surfaces behind the front panel and inside the brewing compartment are hot when power is on. Exercise care around metal surfaces in these areas when the power switch is in the on position.
• During normal operation, the person using the coffee maker must pull it out from the cabinet to fill the coffee bins, etc. To prevent personal injury, when pushing the coffee maker back into the cabinet, make sure body parts and clothing are clear of the portion of the coffee maker behind the front panel.
° To prevent an electrical shock hazard due to steam and water leakage, do not install this appliance above or below any other appliance.
CAUTION
• To prevent jamming of the grinding mechanism, use only the types of coffee beans specified in these instructions.
° Remove the drip tray before closing the front panel door.
Closing the front panel door without the drip tray removed could damage parts of the coffee maker.
• Keep the coffee maker keys in a safe place.
Replacement keys are not covered by the warranty.
• To prevent property damage, the back of the cabinet must be ventilated.
See the location planning section.
• Clean and flush the coffee maker according the the Routine
Cleaning
Instructions
in the use and care guide before using this appliance.
Preparing for Installation
7
PLANNING THE LOCATION
[] !1
II [] [] [] [] [] [] !
[] [] [] [] [] [] [] [] [] [] [] []
J
4" X 12"
(100ram - 300ram)
Ventilation Cut-Out in Cabinet Back
24" i
J
_lomm)
3/4" (19ram)
Min Side Walls
22 1/8"22 3/8"
(582mm - 588mm)
I
Steam Barner
3/4" 19mm)
Level Support Platform
\,
Opt imal Wa te r and Electrical
Supply Location
\\.,
"-.,
8 ....
(203ram)
17 7/8"
(454mm)
I
20 3/4"
527mm )
_ 1/8"
(3ram)
22 3/16" i
(564mm) I i_ ,,_
Screw 8 place
(provided) 3/4" (19ram)
Min Side VYhlls
(26ram)
•
IMPORTANT:
All statutory regulations, local and regional codes and local power supply company connection specifications must be strictly observed.
The supplied power cord is 60" (152.4cm) long, terminated by a three-prong plug.
It is located in the lower right rear corner on the back of the unit. It must be plugged directly into a dedicated, wall-mounted electrical receptacle.
The electrical outlet (and water shut off valve for model E24CM76GSS) should be located in an adjacent cabinet.
Both must be accessible when the unit is installed.
The coffee maker(E24CM76GSS) is supplied with a flexible water hose for connection to a 1/4" threaded water line connection.
See page 12 for further information on planning the water line connection.
The coffee maker must be installed at a safe distance from other sources of heat, such as home appliances, in order to avoid an excessive rise in temperature.
For ventilation purposes, there must be a slot near the top of the cabinet back. The minimum dimensions are 4" X 12" (10.0 X 30.0cm).
8
Preparing for Installation
•
•
IMPORTANT:
DO NOT install the coffee maker in an unrestrained, free-standing cabinet.
During normal operation, the user must have access to the top of the unit.
The user needs to be able to pour coffee into the coffee bins on top and, on model E24CM75GSS, be able to remove the water tank for filling and cleaning.
Install the coffee maker low enough so that the user can reach the top of the unit easily when it is slid out of the cabinet.
When installing the coffee maker under overhanging cabinets, allow sufficient room for access to the coffee bins (and on some models, the water tank) on top. See the table below.
Do not install any appliance above or below the the coffee maker.
Overhanging cabinet
Install unit low enough for easy access to coffee bins on top
0
Veritical distance to overhang
Model
E24CM75GSS
E24CM76GSS
Coffee maker pulled
out fi'om cabinet
Vertical distance to overhang
14" (Minimum)
6" (Minimum)
12" (Recommended)
Preparing for Installation
DIMENSIONS
[] II [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] []
22 1/16 (5&Ocrn)
18 3/16"
(44.0cm)
9
17 9/16"
(44.5crn)
18 3/16"
(46.2crn)
All tolerances: unless otherwise
+ 1/16", - 0" stated.
TECHNICAL SPECIFICATIONS
[] [] [] [] [] [] [] [] [] !1
[] [] [] [] [] [] [] [] [] [] [] []
Power Requirements
Total Connected Load
Power Cord Length
Unit Weight
Shipping Weight
120 Vac, 60Hz, 20A grounded, dedicated circuit required
1.8kW
(15A)
60 inches
110 Ibs.
139 Ibs.
Fresh Water Capacity
(Model E24CM75GSS)
Minimum Input Water Pressure
(Model E24CM76GSS)
Maximum Input Water Pressure
(Model E24CM76GSS)
Water inlet diameter
(Model E24CM76GSS)
5 Liters/1.3
1.40 Bar (20 psi)
2.75 Bar (40
3/4"
Gallons psi)
The correct voltage, frequency and amperage must be supplied to the electrical outlet from a grounded, dedicated, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. If one is not installed, call a licensed electrician.
10
Installation il
BEFOREYOU START
[] [] [] [] [] il [] !1
[] [] [] Ii II [] [] [] [] [] II [] []
Remove the coffee maker from the packaging and inspect it for damage.
Do not install a damaged maker.
To prevent damage to the control panel door, do not set the appliance on the floor or counter prior to installation.
Check to make sure all parts are included.
o
•
PARTS LIST
[] [] [] [] [] [] [] [] [] [] [] [] [] []
Steam barrier with mounting screws
[]
2 guide assemblies with mounting screws
6" metal shims, 1116" (lmm)
[] [] [] [] [] [] []
Three
foot 114" to 314" flexible
water supply hose(E24CM76GSS)
Use & care guide
Detergent tablets (sample)
Spare tank O-ring (model E24CM75GSS)
Spare piston assembly O-ring
Allen wrench (for grinder adjustment)
Anti-liming powder (sample)
Measuring
cup for ground
coffee
Cleaning brush
Keys (taped to the right side of the unit)
Installation
11
•
•
•
•
TOOLS NEEDED FOR INSTALLATION
[] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] []
Phillips screwdriver
Measuring tape
Level
Drill with 1/16" drill bit
[] [] [] [] []
STEAM BARRIERINSTALLATION
[] [] [] [] !!
[] [] [] [] [] [] [] [] [] [] [] [] [] [] [] I!
Position the steam barrier inside the top of the cut-out.
Push it towards the back wall until the back edge lines up with the back of the cabinet.
[]
Attach it with the eight (8) provided screws.
!
I
Steam Barrier
(provided) o
12
Installation
PLUMBING INSTALLATION
[] [] [] [] [] [] [] [] [] [] [] [] [] II [] [] [] [] [] [] [] []
CAUTION
To prevent damage to the coffee maker due to hard water, prior to installation check the water hardness for the building where you will be installing the coffee maker. If necessary have a qualified water treatment specialist install a water treatment system. The water treatment system must be installed between the house plumbing and the coffee maker.
Determine Water Hardness
Before installing the coffee maker, determine the water hardness.
Call the local water company.
Ask them for the water hardness level of the water supplied to the building where the coffee maker will be installed.
•
For Model E24CM75GSS (Tank Model):
If the water hardness level is above four grains per gallon (4 gpg) you must use filtered water with a hardness of 4 gpg or less. Do not use distilled water.
If the water hardness level is below 4 gpg, you may use tap water in the coffee system.
Filtered water is recommended for better taste.
For Model E24CM76GSS (Plumbed Model):
If the water hardness is above 4 grains per gallon (4gpg) contact a qualified water treatment specialist.
Have a water treatment system installed that lowers the water hardness level to 4 gpg or less.
Regardless of the type of water treatment system installed, ELECTROLUX
HIGHLY RECOMMENDS you install an Electrolux ACCFILT-24 filter system.
The coffee maker requires periodic decalcification that must be performed regardless of the water hardness level. The filter head in the kit is required to perform this process for model E24CM76GSS.
Decalcification will be MUCH
SIMPLER with the Electrolux ACCFILT-24 filter system already installed.
In addition, the filter will improve water taste.
Electrolux does not recommend installation of a reverse osmosis filtration system.
Reverse osmosis systems can cause low water pressure.
When the water pressure is low, the coffee water volume level) can fluctuate and the water pump may make a "hammering" sound.
Installation
13
To house water supply t
I
Filter head
To coffee maker
Electrolux ACCFILT-24 Filter Kit with Filter Installed
Everpure Filter
Cartridge
14
Installation
INSTALLING THE CABINET GLIDES
m I m [] [] [] [] [] [] [] [] [] [] B [] [] [] [] [] [] m []
The cabinet glides mount to the inside of the cabinet.
The glides on the coffee maker slide into the cabinet glides.
The guide system allows the coffee maker to slide in and out of the cabinet for loading the coffee bins and for maintenance.
To install the cabinet glides:
Determine the number of metal shims required to mount the cabinet glide assemblies according to the chart and diagrams below. The appliance is supplied with six
Cutout Width Number of Shims
1/16" (1 mm) metal shims.
Use the shims
22 1/8" (56.2cm) 0 to position the fixing
22 3/16" (56.4cm) 2 Total (1 on each side) angles so that they are properly spaced.
The appliance will not slide in and out of the cabinet
22
22
1/4"
3/8"
(56.6cm)
(56.8cm)
4 Total (2 on each side)
6 Total (3 on each side) properly if the fixing angles are not properly spaced.
4"X 12" (100ram X 300ram) Min.
Cabinet Back Cutout for
Air Circulation
3/4" (19mm)--_
Min, Side Walls
22 1/8" (562mm) Min.
Glide
Cabinet
Glide
Asssembl _
Shim
Wall
Cabinet Base
Installation
15
Put the two (2) cabinet glide assemblies, and shims if necessary, as shown on the inside surfaces of the cabinet.
Position them 3 1/2"
(9.0cm) from the front edge of the cutout opening.
Insert the screws in the holes of the glides without tightening them completely.
Make sure the outside distance between the fixing angles is 22 1/8"
(56.2cm) and that the glides are level. Change the number of shims or adjust the fixing angles as necessary.
3
(9.0cm)
IMPORTANT:
Make sure that the glides are level.
18"
(45.7cm)_
4" (100mm)
Cabinet Back Cutout for
Circulati on
•
3 1/2"
Tighten all of the screws.
Make sure that the power cord and water feed line can be fed freely through the back wall.
In order to avoid overheating the coffee maker, make an opening of at least 3
15/16" (10.0cm) at the back of the cabinet to allow air to circulate.
16
Installation
INSTALLING THE UNIT IN THE CABINET
[] m [] [] [] [] [] m [] m [] [] [] [] [] [] [] [] [] [] []
V'_ile supporting the coffee maker from below, insert it into the cabinet cutout.
As you insert it into the cabinet, line up the glides on the appliance with the cabinet glides.
The appliance should glide on the rails when slight pressure is applied to the front of the coffee maker.
If it does not glide smoothly, check the distance between the glides again.
As you slide the coffee maker into the cabinet the locking tab on the glides will engage.
[]
Locking Tab
COFFEE MAKER REMOVAL
[] Ii [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] []
•
If you need to remove the unit from the cabinet:
Disconnect the power plug from the power receptacle.
Press the respective locking tabs on the glides and remove the appliance, supporting it from below.
Installation
17
[]
CONNECTING THE PLUMBING (E24CM76GSS)
[] [] [] II [] [] II [] [] [] [] [] [] [] [] [] [] [] !1
I!
[]
Z WARNING
• To prevent
damage to the coffee system due to hard water, prior to installation, check the water hardness
for the building
where you will be installing the coffee maker.
See page 12
•
To avoid leaks, do not overtighten
fittings.
Insert the 314" gasket into the 314" fitting on the water supply hose.
Make sure it is properly seated.
Connect the 3/4" end of the hose to the water inlet on the back of the coffee maker.
Insert the 1/4" gasket into the 1/4" fitting on the water supply hose.
Make sure it is properly seated.
Connect the other end (1/4") of the hose to the water supply.
Back of Coffee
Maker
Waterlnlet
Power Cord
Gasket
Water Supply
Hose
18
Installation il
VERIFYING OPERATION
[] [] [] [] [] In [] [] [] [] [] Ii II [] [] [] [] [] [] II []
•
z WARNING
• Read the use and care guide completely before operation.
• To keep the grinder from jamming, pour only roasted, unflavored coffee beans into the coffee bean container.
Plug the coffee maker into the dedicated, properly grounded, 3-prong power receptacle.
Test the lights by turning the light switch on and off. It is located on the brewing compartment ceiling, on the far right.
Turn on the power switch.
It is located near the middle of the brewing compartment ceiling.
On model E24CM76GSS (plumbed model): Turn on the water supply at the shut-off valve.
Check the water lines for leaks.
On model E24CM75GSS (tank model): Fill the tank with filtered water (4 gpg maximum water hardness, do not use distilled water).
Push the Hot Water button.
Wait about six (6) seconds.
Hot
Water
Continue to push the hot water button every six (6) seconds until air bubbles no longer come out of the dispenser and about six (6) ounces of water is dispensed.
Clean the coffee system according to the Routine
Cleaning
and
Flushing
Out the Coffee
Maker
sections in the use and care guide.
On model E24CM75GSS, clean the water tank.
Put a sauce pan under the drink dispenser.
Make one of each type of drink in the Operation
Instructions
use and care guide.
section of the
If the coffee maker does not operate properly, follow these troubleshooting
1.
steps:
Verify that power and water are being supplied to the coffee maker.
On
model E24CM75GSS, make sure the water tank is full.
.
,
Make sure that the coffee bins have been properly filled according to the use and care guide.
Check the regulator to make sure it is properly adjusted.
Air in the system during initial operation can cause the initial adjustment to be incorrect.
Installation
19
Troubleshooting (Continued)
4.
Check
the Solutions
to Common
Problems
section of the use and care guide.
,
Repeat the verification process.
6.
If the appliance still does not work, contact an authorized Electrolux at the phone number inside the front cover.
[]
INSTALLATION CHECKLIST
[] Ii [] III [] [] [] [] [] [] []
[] [] [] II [] [] [] il [] []
[]
[3
[]
[]
[]
[]
[]
[]
[]
AkWARNING
To ensure
a safe and proper
installation,
the following
checklist should be completed by the installer to ensure that no part of the installation has been overlooked.
Proper installation importance of proper overemphasized.
is the responsibility installation of the customer.
The of your coffee maker cannot be
Is the coffee maker connected to, or using only soft water (4 gpg maximum hardness)?
See page t2.
Has the coffee maker been cleaned completely prior to use as specified in the use and care guide.
See the use and care guide.
Is the coffee maker connected to a dedicated, grounded power receptacle?
See page 9.
Is there a vent hole in the back of the cabinet to allow heat to escape.
See page 7.
Is the steam barrier installed.
See Page 11.
Are the cabinet glides properly adjusted.
See page 15.
Is the coffee maker locked into the locking tabs on the glides?
See page 16.
On E24CM76GSS: Have the water lines been inspected for leaks?
Has the installer verified proper operation?
See facing page.
1 - 877 - 4 Electrol u x
Electrolux_
www.elecLroluxusa.com
www.electrol
uxca.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project