Miller Syncrowave 351 Owner's Manual
Advertisement
Advertisement
Visit our website at
www.MillerWelds.com
OM-354
December 1997
Processes
TIG (GTAW) Welding
147819 G
Stick (SMAW) Welding
Description
Arc Welding Power Source
R
Syncrowave 351
60 Hz, 50 Hz –
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy.
Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy.
With Miller you can count on years of reliable service with proper maintenance. And if for
Miller is the first welding equipment manufacturer in the U.S.A. to be registered to the ISO 9001 Quality System
Standard.
some reason the unit needs repair, there’s a
Troubleshooting section that will help you figure out what the problem is. The parts list will then help you to decide which exact part you may need to fix the problem. Warranty and service information for your particular model are also provided.
Working as hard as you do
– every power source from
Miller is backed by the most hassle-free warranty in the business.
Miller offers a Technical
Manual which provides more detailed service and parts information for your unit. To obtain a Technical
Manual, contact your local distributor. Your distributor can also supply you with
Welding Process Manuals such as SMAW, GTAW,
GMAW, and GMAW-P.
Miller Electric manufactures a full line of welders and welding related equipment.
For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at www.MillerWelds.com on the web.
WARNING
This product, when used for welding or cutting, produces fumes or gases which contain chemicals known to the
State of California to cause birth defects and, in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
The following terms are used interchangeably throughout this manual:
TIG = GTAW
Stick = SMAW
TABLE OF CONTENTS
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1.
Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2.
Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3.
Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . .
1-4.
Principal Safety Standards
1-5.
EMF Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION
1-1.
Signification des symboles
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2.
Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3.
Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4.
Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5.
Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1.
Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2.
Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3.
Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1.
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2.
Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3.
Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4.
Dimensions and Weights / Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5.
Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6.
Weld Output Terminals And Selecting Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7.
Remote 14 Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8.
115 Volts AC Duplex Receptacle And Shielding Gas Connections . . . . . . . . . . . . . . . . . . . . .
3-9.
Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-10. Placing Jumper Links And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1.
Standard Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2.
Arc/Balance Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3.
Optional Controls (For GTAW Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4.
Setting Optional Pulser Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 – MAINTENANCE & TROUBLESHOOTING
5-1.
Routine Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2.
Circuit Breaker CB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3.
Adjusting Spark Gaps
5-4.
Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5.
Electrical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 – HIGH FREQUENCY (HF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1.
Welding Processes Using HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2.
Sources Of HF Radiation From Incorrect Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3.
Correct Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
12
12
12
13
13
14
14
15
15
16
17
18
18
19
19
20
25
26
26
21
21
21
22
23
26
27
28
10
11
9
9
7
8
8
1
1
1
3
3
4
5
5
5
Declaration of Conformity For
European Community (CE) Products
NOTE
This information is provided for units with CE certification (see rating label on unit.)
Manufacturer’s Name:
Manufacturer’s Address:
Miller Electric Mfg. Co.
1635 W. Spencer Street
Appleton, WI 54914 USA
Declares that the product:
Syncrowave
351
conforms to the following Directives and Standards:
Directives
Low Voltage Directive: 73/23/EEC
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC
Electromagnetic Capability Directives: 89/336, 92/31/EEC
Standards
Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1990
Arc Welding Equipment Part 1: Welding Power Sources: IEC 974-1
(December 1995 – Draft revision)
Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989
Insulation coordination for equipment within low-voltage systems:
Part 1: Principles, requirements and tests: IEC 664-1: 1992
Electromagnetic compatibility (EMC) Product standard for arc welding equipment:
EN50199: August 1995
European Contact:
dec_con1 10/95
Telephone:
Fax:
Mr. Luigi Vacchini, Managing Director
MILLER Europe S.P.A.
Via Privata Iseo
20098 San Giuliano
Milanese, Italy
39(02)98290-1
39(02)98281-552
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_5/97
1-1.
Symbol Usage
Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
Y
Marks a special safety message.
.
Means “Note”; not safety related.
1-2.
Arc Welding Hazards
Y
The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.
Y
Only qualified persons should install, operate, maintain, and repair this unit.
Y
During operation, keep everybody, especially children, away.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions to avoid the hazards.
D
If earth grounding of the workpiece is required, ground it directly with a separate cable – do not use work clamp or work cable.
D
Do not touch electrode if you are in contact with the work, ground, or another electrode from a different machine.
D
Use only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.
D
Wear a safety harness if working above floor level.
D
Keep all panels and covers securely in place.
D
Clamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical.
D
Insulate work clamp when not connected to workpiece to prevent contact with any metal object.
D
Do not connect more than one electrode or work cable to any single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after removal of input power on inverters.
D
Turn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.
D
Do not touch live electrical parts.
D
Wear dry, hole-free insulating gloves and body protection.
D
Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.
D
Do not use AC output in damp areas, if movement is confined, or if there is a danger of falling.
D
Use AC output ONLY if required for the welding process.
D
If AC output is required, use remote output control if present on unit.
D
Disconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D
Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D
Always verify the supply ground – check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.
D
When making input connections, attach proper grounding conductor first – double-check connections.
D
Frequently inspect input power cord for damage or bare wiring – replace cord immediately if damaged – bare wiring can kill.
D
Turn off all equipment when not in use.
D
Do not use worn, damaged, undersized, or poorly spliced cables.
D
Do not drape cables over your body.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.
D
Keep your head out of the fumes. Do not breathe the fumes.
D
If inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases.
D
If ventilation is poor, use an approved air-supplied respirator.
D
Read the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.
D
Work in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D
Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.
D
Do not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.
OM-354 Page 1
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.
D
Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
D
Wear approved safety glasses with side shields under your helmet.
D
Use protective screens or barriers to protect others from flash and glare; warn others not to watch the arc.
D
Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.
D
Protect yourself and others from flying sparks and hot metal.
D
Do not weld where flying sparks can strike flammable material.
D
Remove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers.
D
Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.
D
Watch for fire, and keep a fire extinguisher nearby.
D
Be aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side.
D
Do not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D
Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock and fire hazards.
D
Do not use welder to thaw frozen pipes.
D
Remove stick electrode from holder or cut off welding wire at contact tip when not in use.
D
Wear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap.
D
Remove any combustibles, such as a butane lighter or matches, from your person before doing any welding.
FLYING METAL can injure eyes.
D
Welding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag.
D
Wear approved safety glasses with side shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D
Shut off shielding gas supply when not in use.
D
Always ventilate confined spaces or use approved air-supplied respirator.
HOT PARTS can cause severe burns.
D
Do not touch hot parts bare handed.
D
Allow cooling period before working on gun or torch.
MAGNETIC FIELDS can affect pacemakers.
D
Pacemaker wearers keep away.
D
Wearers should consult their doctor before going near arc welding, gouging, or spot welding operations.
NOISE can damage hearing.
Noise from some processes or equipment can damage hearing.
D
Wear approved ear protection if noise level is high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.
D
Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.
D
Install cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping.
D
Keep cylinders away from any welding or other electrical circuits.
D
Never drape a welding torch over a gas cylinder.
D
Never allow a welding electrode to touch any cylinder.
D
Never weld on a pressurized cylinder – explosion will result.
D
Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and associated parts in good condition.
D
Turn face away from valve outlet when opening cylinder valve.
D
Keep protective cap in place over valve except when cylinder is in use or connected for use.
D
Read and follow instructions on compressed gas cylinders, associated equipment, and CGA publication P-1 listed in Safety
Standards.
OM-354 Page 2
1-3.
Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D
Do not install or place unit on, over, or near combustible surfaces.
D
Do not install unit near flammables.
D
Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
MOVING PARTS can cause injury.
D
Keep away from moving parts such as fans.
D
Keep all doors, panels, covers, and guards closed and securely in place.
FALLING UNIT can cause injury.
D
Use lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories.
D
Use equipment of adequate capacity to lift and support unit.
D
If using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.
OVERUSE can cause OVERHEATING
D
Allow cooling period; follow rated duty cycle.
D
Reduce current or reduce duty cycle before starting to weld again.
D
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
D
Put on grounded wrist strap BEFORE handling boards or parts.
D
Use proper static-proof bags and boxes to store, move, or ship PC boards.
MOVING PARTS can cause injury.
D
Keep away from moving parts.
D
Keep away from pinch points such as drive rolls.
H.F. RADIATION can cause interference.
D
High-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.
D
Have only qualified persons familiar with electronic equipment perform this installation.
D
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
D
If notified by the FCC about interference, stop using the equipment at once.
D
Have the installation regularly checked and maintained.
D
Keep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.
ARC WELDING can cause interference.
D
Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots.
D
Be sure all equipment in the welding area is electromagnetically compatible.
D
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.
D
Locate welding operation 100 meters from any sensitive electronic equipment.
D
Be sure this welding machine is installed and grounded according to this manual.
D
If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.
WELDING WIRE can cause injury.
D
Do not press gun trigger until instructed to do so.
D
Do not point gun toward any part of the body, other people, or any metal when threading welding wire.
1-4.
Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-354 Page 3
1-5.
EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.
To reduce magnetic fields in the workplace, use the following procedures:
1.
Keep cables close together by twisting or taping them.
2.
Arrange cables to one side and away from the operator.
3.
Do not coil or drape cables around your body.
4.
Keep welding power source and cables as far away from operator as practical.
5.
Connect work clamp to workpiece as close to the weld as possible.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended.
OM-354 Page 4
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT
UTILISATION
som _nd_fre 5/97
1-1.
Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
Y
Identifie un message de sécurité particulier.
.
Signifie NOTA ; n’est pas relatif à la sécurité.
1-2.
Dangers relatifs au soudage à l’arc
Y
Les symboles présentés ci-après sont utilisés tout au long du présent manuel pour attirer votre attention et identifier les risques de danger. Lorsque vous voyez un symbole, soyez vigilant et suivez les directives mentionnées afin d’éviter tout danger. Les consignes de sécurité présentées ci-après ne font que résumer l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de sécurité.
Y
L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.
Y
Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension dès que l’appareil est sur ON. Le circuit d’entrée et les circuits internes de l’appareil sont également sous tension à ce moment-là. En soudage semi-automatique ou automatique, le fil, le dévidoir, le logement des galets d’entraînement et les pièces métalliques en contact avec le fil de soudage sont sous tension. Des matériels mal installés ou mal mis à la terre présentent un danger.
D
Ne jamais toucher les pièces électriques sous tension.
D
Porter des gants et des vêtements de protection secs ne comportant pas de trous.
D
S’isoler de la pièce et de la terre au moyen de tapis ou d’autres moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre.
D
Ne pas se servir de source électrique àcourant électrique dans les zones humides, dans les endroits confinés ou là où on risque de tomber.
D
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le procédé de soudage le demande.
D
Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé.
D
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
D
Installer et mettre à la terre correctement cet appareil conformément à son manuel d’utilisation et aux codes nationaux, provinciaux et municipaux.
D
Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D
En effectuant les raccordements d’entrée fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
D
Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas endommagé ou dénudé – remplacer le cordon immédiatement s’il est endommagé – un câble dénudé peut provoquer une électrocution.
D
Mettre l’appareil hors tension quand on ne l’utilise pas.
D
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D
Ne pas enrouler les câbles autour du corps.
D
Si la pièce soudée doit être mise à la terre, le faire directement avec un câble distinct – ne pas utiliser le connecteur de pièce ou le câble de retour.
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou une électrode provenant d’une autre machine.
D
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D
Porter un harnais de sécurité quand on travaille en hauteur.
D
Maintenir solidement en place tous les panneaux et capots.
D
Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec la pièce à souder ou la table de travail, le plus près possible de la soudure.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact avec tout objet métallique.
Il y a DU COURANT CONTINU IMPORTANT dans les convertisseurs après la suppression de l’alimentation électrique.
D
Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie entretien avant de toucher les pièces.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur inhalation peut être dangereux pour votre santé.
D
Eloigner votre tête des fumées. Ne pas respirer les fumées.
D
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau de l’arc pour l’évacuation des fumées et des gaz de soudage.
D
Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué.
D
Lire les spécifications de sécurité des matériaux (MSDSs) et les instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs.
D
Travailler dans un espace fermé seulement s’il est bien ventilé ou en portant un respirateur à alimentation d’air. Demander toujours à un surveillant dûment formé de se tenir à proximité. Des fumées et des gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger.
D
Ne pas souder dans des endroits situés à proximité d’opérations de dégraissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
D
Ne pas souder des métaux munis d’un revêtement, tels que l’acier galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien ventilé, et si nécessaire, en portant un respirateur à alimentation d’air. Les revêtements et tous les métaux renfermant ces éléments peuvent dégager des fumées toxiques en cas de soudage.
OM-354 Page 5
LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et sur la peau.
Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la peau.
Des étincelles sont projetées pendant le soudage.
D
Porter un casque de soudage muni d’un écran de filtre approprié pour protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
D
Porter des protections approuvés pour les oreilles si le niveau sondre est trop élevé.
D
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc.
D
Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds.
LE SOUDAGE peut provoquer un incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels que des réservoirs, tambours ou des conduites peut provoquer leur éclatement. Des étincelles peuvent être projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des incendies et des brûlures. Le contact accidentel de l’électrode avec des objets métalliques peut provoquer des étincelles, une explosion, un surchauffement ou un incendie. Avant de commencer le soudage, vérifier et s’assurer que l’endroit ne présente pas de danger.
D
Se protéger et d’autres personnes de la projection d’étincelles et de métal chaud.
D
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des substances inflammables.
D
Déplacer toutes les substances inflammables à une distance de 10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués.
D
Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et des ouvertures.
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité.
D
Le soudage effectué sur un plafond, plancher, paroi ou séparation peut déclencher un incendie de l’autre côté.
D
Ne pas effectuer le soudage sur des conteneurs fermés tels que des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de sécurité).
D
Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie.
D
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D
En cas de non utilisation, enlever la baguette d’électrode du porte-
électrode ou couper le fil à la pointe de contact.
D
Porter des vêtements de protection dépourvus d’huile tels que des gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef.
D
Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
DES PARTICULES VOLANTES peuvent blesser les yeux.
D
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou même la mort.
D
Fermer l’alimentation du gaz protecteur en cas de non utilisation.
D
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué.
DES PIÈCES CHAUDES peuvent provoquer des brûlures graves.
D
Ne pas toucher des parties chaudes à mains nues
D
Prévoir une période de refroidissement avant d’utiliser le pistolet ou la torche.
LES CHAMPS MAGNÉTIQUES peuvent affecter les stimulateurs cardiaques.
D
Porteurs de stimulateur cardiaque, restez à distance.
D
Les porteurs d’un stimulateur cardiaque doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.
LE BRUIT peut affecter l’ouïe.
Le bruit des processus et des équipements peut affecter l’ouïe.
D
Porter des protections approuvés pour les oreilles si le niveau sondre est trop élevé.
Si des BOUTEILLES sont endommagées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz font normalement partie du procédé de soudage, les manipuler avec précaution.
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive, des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs.
D
Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de se renverser.
D
Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
D
Ne jamais placer une torche de soudage sur une bouteille à gaz.
D
Une électrode de soudage ne doit jamais entrer en contact avec une bouteille.
D
Ne jamais souder une bouteille pressurisée – risque d’explosion.
D
Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et raccords convenables pour cette application spécifique; les maintenir ainsi que les éléments associés en bon état.
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la bouteille.
D
Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille.
D
Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité.
OM-354 Page 6
1-3.
Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
D
Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables.
D
Ne pas installer l’appareil à proximité de produits inflammables
D
Ne pas surcharger l’installation électrique – s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre l’appareil en service.
LA CHUTE DE L’APPAREIL peut blesser.
D
Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire.
D
Utiliser un engin d’une capacité appropriée pour soulever l’appareil.
D
En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser du côté opposé de l’appareil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
Prévoir une période de refroidissement, respecter le cycle opératoire nominal.
D
Réduire le courant ou le cycle opératoire avant de recommancer le soudage.
D
Ne pas obstruer les passages d’air du poste.
LES CHARGES ÉLECTROSTATI-
QUES peuvent endommager les circuits imprimés.
D
Établir la connexion avec la barrette de terre avant de manipuler des cartes ou des pièces.
D
Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des cartes de circuits imprimes.
DES ORGANES MOBILES peuvent provoquer des blessures.
D
Ne pas s’approcher des organes mobiles.
D
Ne pas s’approcher des points de coincement tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent provoquer des blessures.
D
Ne pas appuyer sur la gachette avant d’en avoir reçu l’instruction.
D
Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil de soudage.
DES ORGANES MOBILES peuvent provoquer des blessures.
D
Rester à l’écart des organes mobiles comme le ventilateur.
D
Maintenir fermés et fixement en place les portes, panneaux, recouvrements et dispositifs de protection.
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer des interférences.
D
Le rayonnement haute frequence peut provoquer des interférences avec les équipements de radio–navigation et de communication, les services de sécurité et les ordinateurs.
D
Demander seulement à des personnes qualifiées familiarisées avec des équipements électroniques de faire fonctionner l’installation.
D
L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié les interférences résultant de l’installation.
D
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.
D
Maintenir soigneusement fermés les portes et les panneaux des sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles.
LE SOUDAGE À L’ARC risque de provoquer des interférences.
D
L’énergie électromagnétique risque de provoquer des interférences pour l’équipement électronique sensible tel que les ordinateurs et l’équipement commandé par ordinateur tel que les robots.
D
Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement.
D
Pour réduire la possibilité d’interférence, maintenir les câbles de soudage aussi courts que possible, les grouper, et les poser aussi bas que possible (ex. par terre).
D
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
D
Veiller à ce que ce poste de soudage soit posé et mis à la terre conformément à ce mode d’emploi.
D
En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail.
LES CHAMPS MAGNÉTIQUES peuvent affecter les stimulateurs cardiaques.
D
Porteurs de stimulateur cardiaque, restez à distance.
D
Les porteurs d’un stimulateur cardiaque doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.
OM-354 Page 7
1-4.
Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5.
Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme, des champs magnétiques basse fréquence
Le courant de soudage, pendant son passage dans les câbles de soudage, causera des champs électromagnétiques. Il y a eu et il y a encore un certain souci à propos de tels champs. Cependant, après avoir examiné plus de 500 études qui ont été faites pendant une période de recherche de 17 ans, un comité spécial ruban bleu du National Research Council a conclu: “L’accumulation de preuves, suivant le jugement du comité, n’a pas démontré que l’exposition aux champs magnétiques et champs électriques à haute fréquence représente un risque à la santé humaine”. Toutefois, des études sont toujours en cours et les preuves continuent à être examinées. En attendant que les conclusions finales de la recherche soient établies, il vous serait souhaitable de réduire votre exposition aux champs électromagnétiques pendant le soudage ou le coupage.
Afin de réduire les champs électromagnétiques dans l’environnement de travail, respecter les consignes suivantes :
1 Garder les câbles ensembles en les torsadant ou en les attachant avec du ruban adhésif.
2 Mettre tous les câbles du côté opposé de l’opérateur.
3 Ne pas courber pas et ne pas entourer pas les câbles autour de votre corps.
4 Garder le poste de soudage et les câbles le plus loin possible de vous.
5 Relier la pince de masse le plus près possible de la zone de soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est alors recommandé de respecter les consignes ci–dessus.
OM-354 Page 8
SECTION 2 – DEFINITIONS
2-1.
Warning Label Definitions
1
2
3
4
1.1
2.1
3.1
4.1
+
2.2
1.2
3.2
+
2.3
+
1.3
3.3
Warning! Watch Out! There are possible hazards as shown by the symbols.
1 Electric shock from welding electrode or wiring can kill.
1.1 Wear dry insulating gloves.
Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
1.2 Protect yourself from electric shock by insulating yourself from work and ground.
1.3 Disconnect input plug or power before working on machine.
2 Breathing welding fumes can be hazardous to your health.
2.1 Keep your head out of the fumes.
2.2 Use forced ventilation or local exhaust to remove the fumes.
2.3 Use ventilating fan to remove fumes.
3 Welding sparks can cause explosion or fire.
3.1 Keep flammables away from welding. Don’t weld near flammables.
3.2 Welding sparks can cause fires. Have a fire extinguisher nearby and have a watch person ready to use it.
3.3 Do not weld on drums or any closed containers.
4 Arc rays can burn eyes and injure skin.
4.1 Wear hat and safety glasses.
Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection.
5 Become trained and read the instructions before working on the machine or welding.
6 Do not remove or paint over
(cover) the label.
5 6
+
S-176 254-A
OM-354 Page 9
2-2.
Rating Label For CE Products
OM-354 Page 10
2-3.
Symbols And Definitions
NOTE
Some symbols are found only on CE products.
A
Amperes
V
Volts
Output
Protective Earth
(Ground)
Postflow Timer
S
Seconds
On
Panel–Local
Do Not Switch
While Welding
Circuit Breaker
Alternating
Current
Preflow Timer
Gas Input
Gas Tungsten Arc
Welding (GTAW)
Arc Force (DIG)
Remote
High Frequency -
Start
High Frequency -
Continuous
Gas Output
Off Thickness Gauge
Shielded Metal Arc
Welding (SMAW)
Spot Timer
High Temperature
Input
High Frequency
Gas (Supply)
Direct Current
Balance Control
Maximum
Cleaning
Maximum
Penetration
Electrode Positive
Electrode
Negative
Pulse Frequency
Work
Pulse Percent
On Time
Electrode Single-Phase
Pulse Background
Amperage
Hz
Hertz
Crater Time Percent Start Time Start Amperage
U
0
I
1
Rated No Load
Voltage (Average)
Primary Current
IP
Degree Of
Protection
U
I
2
1
Primary Voltage
Rated Welding
Current
U
2
Conventional Load
Voltage
X
Duty Cycle
1
1
Line Connection
Single-Phase
Combined AC/DC
Power Source
I
1eff
Maximum Effective
Supply Current
I
1max
Rated Maximum
Supply Current
Spark Gap
Increase/Decrease
Of Quantity
OM-354 Page 11
SECTION 3 – INSTALLATION
3-1.
Specifications
Rated
Welding
Output
Amperes Input at AC Balanced Rated Load Output,
50/60 Hz, Single-Phase
PFC**
200 V 220 V 230 V 380 V 415 V 460 V 575 V
KVA KW
NEMA Class I
(60) – 300
Amperes, 32
Volts AC, 60%
Duty Cycle
No
PFC
With
PFC
NEMA Class II
(40) – 350
Amperes, 34
Volts AC, 40%
Duty Cycle
No
PFC
With
PFC
*While idling
**Power Factor Correction
130
(5.6*)
112
(69*)
151
(5.6*)
131
(69*)
138
88
112
(4.9*)
84
(60*)
131
(4.9*)
102
(60*)
80
51
73
47
57
(2.4*)
45
(30*)
67
(2.4*)
53
(30*)
46
(1.9*)
34
(24*)
52
(1.9*)
43
(24*)
26
(1.14*)
13.7
(0.42*)
20.6
(13.9*)
13.6
(0.59*)
30.3
(1.14*)
17.4
(0.42*)
24.6
(13.9*)
17.3
(0.59*)
Amperage
Range
3 – 430A
3 – 430A
Max
OCV
80
80
3-2.
Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating.
If unit overheats, thermostat opens, output stops, light goes on (CE
Models Only), and cooling fans run.
Wait fifteen minutes for unit to cool.
Reduce amperage or duty cycle before welding.
Y
Exceeding duty cycle can damage unit and void warranty.
40% Duty Cycle At 350 Amperes (60 Hz Models Only)
60% Duty Cycle At 300 Amperes
4 Minutes Welding
Overheating
6 Minutes Resting
0
Minutes
15
6 Minutes Welding
A
OR
Reduce Duty Cycle
4 Minutes Resting duty1 4/95 / SB-159 284
OM-354 Page 12
3-3.
Volt-Ampere Curves
A. DC Mode
The volt-ampere curves show the minimum and maximum voltage and amperage output capabilities of the welding power source. Curves of other settings fall between the curves shown.
B. AC Mode
*
*During low arc voltage conditions (short arc length), increasing
Arc Control setting increases amperage (see Section 4-2).
3-4.
Dimensions and Weights / Selecting A Location
Movement
Location And Airflow
3
1
1
OR ssb1.1 10/91 – ST-159 286 / ST-159 285
6
4
5
2
Net Weight: 541 lb (245 kg), Length:
22-1/2 in (577 mm), Width: 24 in
(577 mm), Height: 44 in (1,218 mm) with retractable lifting eye down.
1 Lifting Eye
2 Lifting Forks
Use lifting eye or lifting forks to move unit.
If using lifting forks, extend forks beyond opposite side of unit.
3 Rating Label (Non CE Models
Only)
4 Rating Label (CE Models
Only, See Section 2-2)
Use rating label to determine input power needs. CE label located on rear panel.
5 Plate Label (CE Models Only)
6 Line Disconnect Device
Locate unit near correct input power supply.
Y
Special installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC
Section 20.
18 in (460 mm)
18 in (460 mm)
ST-800 402 / ST-117 264-C
TM-354 Page 13
3-5.
Tipping
Y
Be careful when placing or moving unit over uneven surfaces.
3-6.
Weld Output Terminals And Selecting Cable Sizes
Y
ARC WELDING can cause Electromagnetic Interference.
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.
Weld Output
Terminals
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10 – 60%
Duty
Cycle
60 – 100%
Duty
Cycle
10 – 100% Duty Cycle
100
150
200
250
4
3
3
2
4
3
2
1
4
2
1
1/0
3
1
1/0
2/0
2
1/0
2/0
3/0
1
2/0
3/0
4/0
1/0
3/0
4/0
2-2/0
300
350
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2-2/0
2-2/0
2-3/0
2-3/0
2-3/0
Work Electrode
400 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0
Ref. ST-149 842-E
500 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0
Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
3-3/0
1/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
3-3/0
S-0007-D
OM-354 Page 14
3-7.
Remote 14 Receptacle
B
A
K
C
L
D
M
N
E
J
I
F
G
H
ST-149 842-E
*The remaining sockets are not used.
A
Socket*
D
E
K
A
B
C
Socket Information
24 volts ac.
Contact closure to A completes 24 volts ac contactor control circuit.
Command reference; 0 to +10 volts dc output to remote control.
Remote control circuit common.
0 to +10 volts dc input command signal from remote control.
Chassis common.
3-8.
115 Volts AC Duplex Receptacle And Shielding Gas Connections
6
5
4
Y
Turn Off power before connecting to receptacle.
1 115 V AC Receptacle
Receptacle is protected from overload by circuit breaker CB1 (see
Section 5-2).
2 Gas Valve In Fitting
3 Gas Valve Out Fitting
Fittings have 5/8-18 right-hand threads.
4 Cylinder Valve
Open valve slightly so gas flow blows dirt from valve. Close valve.
5 Regulator/Flow Gauge
6 Flow Adjust
Typical flow rate is 20 cfh (cubic feet per hour).
1
3
2
Ref. ST-154 795-B / Ref. ST-149 842-E
TM-354 Page 15
3-9.
Electrical Service Guide
NOTE
All values calculated at 60% duty cycle.
60 Hertz Models
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit
Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In
Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC)
200
2
150
(46)
6
200
130
Without Power
Factor Correction
230
112
460
57
575
46
175
3
168
(51)
6
80
8
262
(80)
8
70
8
409
(25)
8
150
4
117
(36)
6
200
112
With Power
Factor Correction
230
84
460
45
575
34
125
4
154
(47)
6
70
8
273
(83)
8
50
10
287
(87)
10
S-0092-J
NOTE
All values calculated at 60% duty cycle.
50 Hertz Models
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit
Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In
Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC)
200
3
125
(38)
6
220
Without Power
Factor Correction
380 415
138 80 73
125
6
214
(65)
6
110
8
170
(52)
8
150
4
141
(43)
6
220
With Power
Factor Correction
380 415
88 51 47
80
8
187
(57)
8
70
8
222
(68)
8
S-0092-J
OM-354 Page 16
3-10. Placing Jumper Links And Connecting Input Power
220 VOLTS
L L
230 VOLTS
L L
Connect GND/PE
Conductor First
200 VOLTS
L L
230 VOLTS
L L
380 VOLTS
L L
460 VOLTS
L L
460 VOLTS
L L
S-083 566-C
415 VOLTS
L L
S-131 783-A
575 VOLTS
L L
S-010 587-B
2
1
GND/PE
Earth Ground
Check input voltage available at site.
1 Jumper Link Label
Check label – only one is on unit.
2 Jumper Links
Move jumper links to match input voltage.
3 Input And Grounding
Conductors
Select size and length using Section 3-9.
4 Line Disconnect Device
Select type and size of overcurrent protection using Section 3-9.
Reinstall side panel.
Y
Special installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC
Section 20.
4
L1 (U)
L2 (V)
3
Connect GND/PE
Conductor First
Tools Needed:
3/8 in
3/8, 1/2, 7/16 in
Ref. ST-149 843-C
TM-354 Page 17
4-1.
Standard Controls
SECTION 4 – OPERATION
1 2 3 4 6 7 8 9 10
11
5
13
12
.
Place 4 switches in upper left corner up for SMAW and down for GTAW.
1 Mode Switch
Switch selects SMAW or GTAW.
2 Amperage Control Switch
Switch selects front panel or remote amperage control.
3 Output Switch
Y
Weld output terminals are energized when Output switch is On and Power is On.
Switch selects front panel or remote output control.
4 High Frequency Switch
For GTAW, use switch to select continuous
HF, HF for arc starting only, or no HF.
5 High Frequency Control
For GTAW, use control to set HF intensity.
Set as low as possible.
6 Ammeter
7 Voltmeter
8 Amperage Adjustment
Control
.
Control can be turned past the minimum and maximum stops without damage to the control.
Control requires 3 turns to go from minimum to maximum. Use ammeter to preset amps.
For remote amperage control, front panel control setting is the maximum amperage available. For example: If front panel control is set to 200 A, the range of the remote amperage control is 0 to 200 A.
9 Arc/Balance Control
Control functions as an arc control for
SMAW DC output and as a balance control for AC output (see Section 4-2 for more information).
10 Postflow Time Control
Control sets length of time gas flows after welding stops.
11 Power Switch Pushbuttons
12 Output Selector Switch
13 High Temperature Shutdown Light (CE
Models Only)
Lights when unit overheats and shuts down
(see Section 3-2).
Ref. ST-154 795-B / Ref. ST-149 842-E
OM-354 Page 18
4-2.
Arc/Balance Control
Balanced
30
Setting
More Penetration
100
More Cleaning
0
Balance Control Examples
Output Waveforms
50% Electrode
Positive
50% Electrode
Negative
32% Electrode
Positive
68% Electrode
Negative
55% Electrode
Positive
45% Electrode
Negative
Arc
Arc Control (DC SMAW):
Control helps arc starting or making vertical or overhead welds by increasing amperage at low arc voltage.
When set at 0, short-circuit amperage at low arc voltage is the same as normal welding amperage.
When setting is increased, shortcircuit amperage at low arc voltage increases.
Balance Control (AC):
Control changes the ac output square wave.
Adjust setting for deeper penetration or more cleaning action. Position 30 (balanced) is a recommended starting point for GTAW.
Ref. S-0795-A
4-3.
Optional Controls (For GTAW Only)
1
10
9
2
8
3
7
4
5 6
Ref. ST-154 795-B
Preflow/Spot Timer Controls:
1 Preflow Time Control And Switch
Control sets length of time that gas flows before arc starts.
2 Spot Time Control And Switch
Control sets spot weld time. Timer begins when arc starts. If arc is broken during spot time cycle, timer stops but does not reset.
When spot time ends, arc stops and timer resets for next cycle.
Start Controls/Crater Fill Controls:
3 Start Amperage Control
4 Start Time Control
5 Start Control Switch
Use start control to select a starting amperage that is different from the weld amperage.
Start Amperage control can be adjusted from
0 to 400 A (100% = 400 A).
For example, to select start amperage of 300
A for 3 seconds and weld amperage of 200
A: Set start Amperage control to 75 (75% of
400 A = 300 A), set start time control to 3, and set front panel or remote amperage control to 200 A.
6 Crater Fill Control And Switch
Control sets length of time to taper weld output from weld amperage setting to 0 A.
.
Be sure to set Postflow control for a longer period of time than the Crater Fill control.
Pulser Controls:
7 Background Amperage Control
8 Pulses Per Second Control
9 % On Time
10 Pulser On/Off Switch
Use controls to set pulsing parameters (see
Section 4-4 for more information).
TM-354 Page 19
4-4.
Setting Optional Pulser Controls
Percent (%) On Time
Control Setting
(50%)
Balanced
Pulser Examples
Pulsed Output Waveforms
3
2
1
More Time
At Peak
Amperage
More Time At
Background
Amperage
(20%)
(80%)
1 Peak Amperage
2 Background Amperage
Use Background Amperage control to set the low pulse of weld amperage which cools the weld puddle. Peak amperage, which is the front panel or remote control amperage setting, is the high pulse which heats the weld puddle. Background amperage setting is a percent of the peak amperage.
3 One Pulse Period
Use Percent On Time control to set percent of pulse period that is at peak amperage.
Use Pulses Per Second control to set number of pulse periods that occur in one second.
OM-354 Page 20
SECTION 5 – MAINTENANCE & TROUBLESHOOTING
5-1.
Routine Maintenance
Y
Disconnect power before maintaining.
3 Months
Replace
Unreadable
Labels
Repair Or
Replace
Cracked
Weld
Cables
Adjust Spark
Gaps
14-Pin Cord
6 Months
Gas Hose
OR
Blow Out Or Vacuum
Inside,
During Heavy Service,
Clean Monthly
Torch Cable
Clean And
Tighten
Weld
Terminals
Replace
Cracked
Parts
5-2.
Circuit Breaker CB1
1 Circuit Breaker CB1
If CB1 opens, high frequency and output to the 115 volts ac duplex receptacle stop. Press button to reset breaker.
1
CB1
(15A)
Ref. ST-149 842-E / Ref. ST-146 562-C
TM-354 Page 21
5-3.
Adjusting Spark Gaps
4 3
2
1
Tools Needed:
0.008 in (0.203 mm)
5/32 in
Y
Turn Off power before adjusting spark gaps.
Open access door.
1 Tungsten End Of Point
Replace point if tungsten end disappears; do not clean or dress tungsten.
2 Spark Gap
Normal spark gap is 0.008 in (0.203
mm).
If adjustment is needed, proceed as follows:
3 Adjustment Screws
Loosen screws. Place gauge of proper thickness in spark gap.
4 Pressure Point
Apply slight pressure at point until gauge is held firmly in gap. Tighten screws. Adjust other gap.
Close access door.
Ref. ST-149 842-E / Ref. S-0043
OM-354 Page 22
5-4.
Troubleshooting
Trouble Remedy
No weld output; unit completely inoperative.
No weld output; unit on.
Unit provides only maximum or minimum weld output.
Place line disconnect switch in On position (see Section 3-10).
Check and replace line fuse(s), if necessary (see Section 3-10).
Check for proper input power connections (see Section 3-10).
Check for proper jumper link position (see Section 3-10).
If using remote control, place Output switch in Remote 14 position, and make sure remote control is connected to Remote 14 receptacle. If remote is not being used, place Output switch in On position
(see Section 4-1).
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fans On (see Section 3-2).
Have Factory Authorized Service Agent check control board PC1.
Make sure Amperage switch is in proper position (see Section 4-1).
Have Factory Authorized Service Agent check hall device HD1, filter board PC2, and control board
PC1.
Erratic or improper weld output.
No control of weld output.
Use proper size and type of weld cable (see Section 3-6).
Clean and tighten all weld connections.
Check position of Output Selector switch (see Section Figure 4-1).
If using remote control, check position of Amperage Adjustment control (see Section 4-1).
If using remote control, place Output switch in Remote 14 position, and make sure remote control is connected to Remote 14 receptacle. If remote is not being used, place Output switch in On position
(see Section 4-1).
No Arc/Balance Control.
Make sure Amperage switch is in proper position (see Section 4-1).
Make sure Arc/Balance Control is in proper position (see Section 4-1).
Have Factory Authorized Service Agent check main potentiometer board PC5 and control board PC1.
No output from duplex receptacle RC2 and no high frequency.
Reset circuit breaker CB1 (see Section 5-2).
Remote 14 receptacle RC1 not working properly.
Lack of high frequency; difficulty in starting GTAW arc.
Be sure Amperage control switch and Output switch are in Remote 14 position (see Section 4-1).
Wandering arc – poor control of direction of arc.
Reset circuit breaker CB1 (see Section 5-2).
Select proper size tungsten.
Check High Frequency Intensity control setting (see Figure 4-1).
Be sure electrode holder cable is not close to any grounded metal.
Check cables and torch for cracked insulation or bad connections. Repair or replace.
Check spark gaps (see Section 5-3).
Reduce gas flow rate.
Select proper size tungsten.
Properly prepare tungsten.
TM-354 Page 23
Trouble
Tungsten electrode oxidizing and not remaining bright after conclusion of weld.
Fan not operating. NOTE: fan only runs when cooling is necessary.
Remedy
Shield weld zone from drafts.
Increase postflow time.
Check and tighten all gas fittings.
Properly prepare tungsten.
Check for water in torch, and repair torch if necessary.
Check and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor.
OM-354 Page 24
5-5.
Electrical Diagram
SC-181 682-D
OM-354 Page 25
SECTION 6 – HIGH FREQUENCY (HF)
6-1.
Welding Processes Using HF
1
2
1
1 HF Voltage
GTAW – helps arc jump air gap between torch and workpiece and/ or stabilize the arc.
SAW – helps arc reach workpiece through flux granules.
2 Flux
Work
Gas Tungsten Arc
Welding (GTAW)
Work
Submerged Arc
Welding (SAW) high_freq1 7/95 – S-0693
6-2.
Sources Of HF Radiation From Incorrect Installation
Weld Zone
11, 12
50 ft
(15 m)
9
8
7
10
14
3
2
13
1
4 5 6
Sources Of Direct HF Radiation
1 HF source (welding power source with built-in HF or separate HF unit)
2 Weld Cables
3 Torch
4 Work Clamp
5 Workpiece
6 Work Table
Sources Of Conduction Of HF
7 Input Power Cable
8 Line Disconnect Device
9 Input Supply Wiring
Sources Of Reradiation Of HF
10 Ungrounded Metal Objects
11 Lighting
12 Wiring
13 Water Pipes And Fixtures
14 External Phone And Power Lines
S-0694
OM-354 Page 26
6-3.
Correct Installation
50 ft
(15 m)
Weld Zone
6
50 ft
(15 m)
4
1
5
3
2
7
7
Ground All
Metal Objects
And All Wiring
In Welding Zone
Using #12 AWG
Wire
Ground
Workpiece
If Required
By Codes
Nonmetal
Building
8
7
7
10
Metal Building
9
1 HF Source (Welder With Built-In HF Or
Separate HF Unit)
Ground metal machine case, work output terminal, line disconnect device, input supply, and worktable.
2 Welding Zone And Centerpoint
A circle 50 ft (15 m) from centerpoint between HF source and welding torch in all directions.
3 Weld Output Cables
Keep cables short and close together.
4 Conduit Joint Bonding And Grounding
Electrically join (bond) all conduit sections using copper straps or braided wire. Ground conduit every 50 ft (15 m).
5 Water Pipes And Fixtures
Ground water pipes every 50 ft (15 m).
6 External Power Or Telephone Lines
Locate HF source at least 50 ft (15 m) away from power and phone lines.
7 Grounding Rod
Consult the National Electrical Code for specifications.
Ref. S-0695 / Ref. S-0695
8 Metal Building Panel Bonding Methods
Bolt or weld building panels together, install copper straps or braided wire across seams, and ground frame.
9 Windows And Doorways
Cover all windows and doorways with grounded copper screen of not more than
1/4 in (6.4 mm) mesh.
10 Overhead Door Track
Ground the track.
OM-354 Page 27
SECTION 7 – PARTS LIST
.
Hardware is common and not available unless listed.
OM-354 Page 28
Figure 7-1. Main Assembly
ST-149 844-D
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-1. Main Assembly
Quantity
. . . 1 . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . . .
182 126
155 904
. . .
. . .
COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BRACKET, lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . . .
026 627
155 905
. . .
. . .
GASKET, lift eye
LIFT EYE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
5
6
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
155 903
155 902
. . .
. . .
BUSHING, lift eye
SUPPORT, lift eye
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . . . . Fig 7-3 . . . BAFFLE, w/components
. . . 8 . . . . . . . . . . . . . . . . 145 045 . . . BRACKET, mtg baffle fan
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
9
10
. . . . .
. . . . .
C5,6
TE1
. . . . .
. . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
111 634
034 587
601 835
601 836
. . .
. . .
CAPACITOR
. . . .
. . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TERMINAL ASSEMBLY, pri (consisting of) . . . . . . . . . . . . . . . . . . . . . . . .
1
1
NUT, brs hex 10-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NUT, brs hex .250-20 jam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
4
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
010 915
083 426
038 888
038 887
010 913
602 207
038 618
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
WASHER, flat brs .250 ID x .625 OD x .031thk
TERMINAL BOARD, pri
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STUD, primary bd brs .250-20 x 1.500
STUD, primary bd brs 10-32 x 1.375
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
WASHER, flat brs .218 ID x .460 OD x .031thk
. . . . . . . . . . . . . . . . . .
WASHER, lock .255 ID x .489 OD
LINK, jumper term bd pri
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
6
4
1
6
2
2
2
1
1
1
1
1
1
1
. . .
. . .
11
13
. . . . . . . . . . . . . . . .
. . . 12 . . . . . . T2 . . . . . .
. . . . . CR2 . . . . .
. . . 14 . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
144 757
140 846
110 386
157 416
169 488
. . .
. . .
. . .
. . .
. . .
BAFFLE, air rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRANSFORMER, control 230VAC pri 11.5/18/24VAC
RELAY, encl 24VDC DPDT 5A/120V
PANEL, mtg component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BRACKET, support electrical box
. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 15 . . . . . . . . . . . . . . . .
. . . 16 . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
152 582 . . . BRACKET, mtg panel rear
♦
150 377 . . . CLAMP, capacitor
♦
601 835 . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NUT, brs hex 10-32 (used on pri brd) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 . . . . . . . . . . . . . . . .
. . .
. . .
. . .
18
19
20
. . . . C15-19 . .
♦
125 781 CAPACITOR, polyp film 150uf 250VAC
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
♦
109 035 . . . LABEL, warning electric shock can kill
129 201
+182 129
. . .
. . .
. . .
BRACKET, mtg capacitor
PANEL, rear
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . 21 . . . . . . . . . . . . . . . .
176 272
145 693
. . .
. . .
CONNECTOR, cable clamp (50Hz model)
INSULATION, leads pri
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 22 . . . . . . . . . . . . . . . .
. . . 23 . . . . . . . . . . . . . . . .
144 758
182 608
. . .
. . .
BRACKET, mtg panel rear
PANEL, side RH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 24 . . . . . SR1 . . . . .
. . . 25 . . . . . . T1 . . . . . .
144 849
183 352
. . .
. . .
RECTIFIER, SCR main RH (Fig 7-9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRANSFORMER/STABILIZER ASSY, 200/230/460 . . . . . . . . . . . . . . . .
. . . 25 . . . . . . T1 . . . . . . 183 353 . . . TRANSFORMER/STABILIZER ASSY, 230/460/575 . . . . . . . . . . . . . . . .
. . . 25 . . . . . . T1 . . . . . .
. . . . . . . . . . TP1,2 . . . . .
183 354
020 520
. . .
. . .
TRANSFORMER/STABILIZER ASSY, 220/380/415
THERMOSTAT, NC (thermal shutdown)
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
2
1
1
1
1
1
1
1
6
1
1
1
5
2
1
1
1
1
. . . . . . . . . . .
. . . 26
TP3 . . . . . .
. . . . . . . . . . . . . . . .
168 891
144 762
. . .
. . .
THERMOSTAT, NC (fan on demand)
FOOT, base rear
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 27 . . . . . . . . . . . . . . . .
. . . 28 . . . . . . . . . . . . . . . .
144 743
010 494
. . .
. . .
BAFFLE, contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BUSHING, snap-in nyl 1.375 ID x 1.750mtg
. . . . . . . . . . . . . . . . . . . . . . .
. . . 29 . . . . . D2,3 . . . . .
. . . 30 . . . . . . W . . . . . .
082 456
187 416
. . .
. . .
DIODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactor, with bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 31 . . . . . . . . . . . . . . . .
. . . 32 . . . . . . . . . . . . . . . .
144 745
144 761
. . . BASE, (consisting of)
. . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FOOT, base front RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 33 . . . . . . . . . . . . . . . . 144 739
. . . 34 . . . . . . . . . . . . . . . .
. . . 35 . . . . . . . . . . . . . . . .
144 760
146 093
. . . .
. . . .
. . . .
FRAME, base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FOOT, base front LH
FOOT, base side LH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 36 . . . . . . . . . . . . . . . . .
. . . 37 . . . . . . . . . . . . . . . . .
Fig 7-6
Fig 7-2
. . .
. . .
PANEL, front w/components
HF PANEL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 38 . . . . . SR1 . . . . .
. . . 39 . . . . . . . . . . . . . . . .
182 114
086 863
. . .
. . .
RECTIFIER, SCR main LH (Fig 7-9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCREW, cap stl hex whd .375-16 x 1.000
. . . . . . . . . . . . . . . . . . . . . . . .
. . . 40 . . . . . . . . . . . . . . . . 182 607 . . . PANEL, side LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
♦
Part of 042 671 Optional Power Factor Correction.
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 29
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-2. HF Panel (Fig 7-1 Item 37)
Quantity
. . .
. . .
1
2
. . . . . .
. . . .
C3
C1,11
. . . . . .
. . . . .
096 761
106 935
. . .
. . .
CAPACITOR, mica .002uf 10000V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAPACITOR, polyp film 10uf 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . LF2 . . . . . . 084 171 . . . FILTER, line pwr 115/250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . . .
. . . 5 . . . . . . R1 . . . . . .
010 494
186 468
. . .
. . .
BUSHING, snap-in nyl 1.375 ID x 1.750mtg hole
RESISTOR, WW fxd 100W 50 ohm
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . R2 . . . . . . 182 417 . . . RESISTOR ASSEMBLY, WW fxd 5W . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . . .
. . . 8 . . . . . . . . . . . . . . . .
182 120
149 950
. . .
. . .
PANEL, HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BRACKET, mtg spark gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . . .
149 951
020 623
. . .
. . .
INSULATOR, bracket mtg spark gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPARK GAP ASSEMBLY (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
095 621
020 622
. . . .
. . . .
BASE, spark gap
HOLDER, points
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . . T3 . . . . . .
020 603
074 398
. . . .
. . .
POINT, spark gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRANSFORMER, high voltage 115V pri 3600V sec 30mA . . . . . . . . . .
1
4
4
1
1
1
1
1
1
1
1
1
1
2
2 4
1
3
5
6
7
11
8
.
Hardware is common and not available unless listed.
9
10
Figure 7-2. HF Panel
ST-150 188-A
*Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 30
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-3. Baffle, w/Components (Fig 7-1 Item 7)
Quantity
. . . 1 . . . . . . . . . . . . . . . .
. . . 2 . . . . FM1,2 . . . . .
157 874 . . . BRACKET, mounting motor fan
148 808 . . . MOTOR, fan 230V 1550RPM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . . 150 783 . . . BLADE, fan 9 in .312 hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . R4 . . . . . .
. . . 5 . . . . . . R3 . . . . . .
186 949
118 459
. . .
. . .
RESISTOR, WW fxd 175W 20 ohm
RESISTOR
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . . . . . . .
. . . 7 . . . . . . C2 . . . . . .
168 976
031 668
. . .
. . .
INSULATOR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAPACITOR, elctlt 4000uf 100VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . . .
108 105
155 906
. . .
. . .
CLAMP, capacitor 2.500 mtg
BAFFLE, fan
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . . .
. . . 11 . . . . . . 1T . . . . . .
004 214
038 772
. . .
. . .
BUSHING, snap-in nyl 1.625 ID x 2.000mtg hole
BLOCK, term 20A 6P
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . 035 129 . . . CONNECTOR, blk 20A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
2
2
2
2
1
4
1
2
3
.
Hardware is common and not available unless listed.
1 2
4
5
11
6
10
7
9
8
Figure 7-3. Baffle, w/Components
ST-150 187-B
6
5
4
3
ST-150 186-B
Figure 7-4. Panel, Center w/Components
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-4. Panel, Center w/Components (Fig 7-6 Item 9)
Quantity
. . .
. . .
1
2
. . . . . . . . . . . . . . . .
. . . . S5A,B . . . . .
. . . . . . . . . . . . . . . . . . . . . .
182 121 . . . PANEL, mtg components
169 142 . . . SWITCH, polarity 5posn
021 795 . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TUBING, stl .375 OD x 18ga wall x .750 lg . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . 3
PLG35
PLG36
. . . . . . 2T
. . . .
. . . .
164 899
168 809
. . .
. . .
CONNECTOR & SOCKETS
CONNECTOR & PINS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 038 621 . . . BLOCK, term 30A 4P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . SR2 . . . . .
038 620 . . . LINK, jumper term blk 30A
035 704 . . . RECTIFIER, integ 40A 800V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . . .
. . . 6 . . . . . CR1 . . . . .
030 170
052 603
. . .
. . .
BUSHING, snap-in nyl .750 ID x 1.000mtg hole
RELAY, encl 110VDC DPDT
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
2
2
1
1
1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 31
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-5. Panel, Front Upper w/Components (Fig 7-6 Item 10)
Quantity
. . 1 . . . . .
. . 2 . . . . . .
S1-3
S4
. . . . . . 145 475 . . . SWITCH, tgl SPDT 15A 125VAC
. . . . . . . 145 476 . . . SWITCH, tgl DPDT 15A 125VAC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 3 . . . . . . . . . . . . . . . . .
. . 4 . . . . . . . . . . . . . . . . .
173 997
078 034
. . .
. . .
RETAINER, screw No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FASTENER, screw sltd hd .736 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .
. .
5
6
. . . PLG16,26
. . . . . PC6
. . . .
. . . . . .
155 511 . . . CABLE, ribbon 10posn
157 741 . . . CIRCUIT CARD, meter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 7 . . . . . . . . . . . . . . . . .
. . 8 . . . . . . . . . . . . . . . . .
107 551
010 494
. . .
. . .
STRAIN RELIEF, cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BUSHING, snap-in nyl 1.375 ID x 1.750mtg hole . . . . . . . . . . . . . . . . . .
. . 9 . . . . .
. . . . . . . . . .
. . . . . . . . . .
PC3
PLG3
PLG5
. . . . . .
. . . . . .
. . . . . .
140 028
115 094
. . .
. . .
CIRCUIT CARD, relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONNECTOR & SOCKETS
115 093 . . . CONNECTOR & SOCKETS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
3
1
1
1
1
1
1
9
.
Hardware is common and not available unless listed.
8
10
11
12
1
2 5 6
7
13
14
3
4
15
18
19
20
17
40
39
38
37
35
36
34
32
33
21
22
16
12
23
19
31 30
29 28
Figure 7-5. Panel, Front Upper w/Components
24
25
26
27
ST-150 190-C
OM-354 Page 32
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-5. Panel, Front Upper w/Components (Fig 7-6 Item 10)
(Continued)
Quantity
. . . . . . . . . . PLG6
. . 10 . . . .
. . . . . . . . . .
PC2
PLG8
. . . . . . 131 056 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 182 154 . . . CIRCUIT CARD, filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 115 092 . . . CONNECTOR & SOCKETS, (see Fig 7-9)
1
1
. . . . . . . . .
. . . . . . . . .
. .
. .
11
12
PLG10
PLG11
. . .
. .
PLG4,9
PLG7,12
. . . . . 115 091 . . . CONNECTOR & SOCKETS
. . . . . 115 093 . . . CONNECTOR & SOCKETS
. . . . .
. . . .
142 142
142 141
. . .
. . .
CABLE, ribbon 14posn
CABLE, ribbon 40posn
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .
. .
13
14
1
1
1
1
. . . . . LF1 . . . . . . 084 171 . . . FILTER, line pwr 115/250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
20
. .
. .
15
16
. . 17
. . 18
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
182 124
098 691
155 433
110 375
. . .
. . .
. . .
. . .
ELECTRONICS BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STAND-OFF, No. 6-32 x .500 lg
HINGE, mtg front electronics
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .
. .
19
20
. . PLG25,28
. . . . PC5
. . . .
. . . . . .
142 139
139 969
. . .
. . .
CABLE, ribbon 14 posn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT CARD, main pot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .
. .
21
22
. . . . . . . . . . . . . . . .
. . . . PC1 . . . . . .
155 516
186 768
. . .
. . .
COVER, front electrical box
CIRCUIT CARD, control
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. .
. .
. .
. .
. .
. .
. .
PLG17
PLG14
. . . . .
. . . . .
115 094
115 091
. . .
. . .
CONNECTOR & SOCKETS
CONNECTOR & SOCKETS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
24 PLG19,23
♦
142 143 CABLE, ribbon 14posn
25
26
27
. .
. .
. . . .
. .
PLG15,24
PLG21,22
. . . .
PC9
PC7
. . . .
. .
. . . .
.
. . .
142 139 . . . CABLE, ribbon 10posn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
♦
139 309 CIRCUIT CARD, crater fill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
♦♦
♦♦
142 140
139 398
. . .
. . .
. . .
CABLE, ribbon 10posn
CIRCUIT CARD, pulser
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28 . . . . . . . . . . . . . . See Note . . . PLATE, indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29 . . . . . . . . . . . . . . . . 097 922 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .
. .
. .
. .
. .
30
31
32
33
34
. . . . . . . . . . . . . . . . 135 299 . . . LOCK, shaft pot .375-32 x .250dia shaft . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
097 924
♦♦♦
093 551
. . .
. . .
KNOB, pointer
PULSER, (consisting of)
. . . . KNOB
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . PC8
See Note
. . . . . . 139 528
. . . .
. . . .
PLATE, control pulser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT CARD, pulser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. .
. .
35
36
See Note
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
♦♦♦
See Note
. . .
. . .
COVER, opening pulser control (not used when unit has pulser option) 1
START CURRENT/crater fill, (consisting of)
. . . . PLATE, control start/crater control
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
. . 37 . . . . . . . . . . . . . . . . 093 551 . . . . KNOB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PC10 . . . . . .
. . . . . . . . . . . . . . . . . . . .
139 524
See Note
. . . .
. . .
CIRCUIT CARD, crater/start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COVER, opening start/crater control
3
1
(Not used when unit has start current/crater fill option) . . . . . . . . . . . . .
. . .
. . .
38
39
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
♦♦♦
See Note
. . . 40 . . . . . . . . . . . . . . . . 093 551
. . . PRE-FLOW/SPOT TIMER, (consisting of)
. . . .
. . . .
. . . .
. . . . . . . . . . . . . . . . . . . . . . . .
PLATE, control pre-flow/spot timer
KNOB
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT CARD, pre-flow/spot timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PC11 . . . . . 139 973
. . . . . . . . . PLG15,24 . . .
. . . . . . . . . . . . . . . . . . . .
142 138
See Note
. . . .
. . .
CABLE, ribbon 14posn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COVER, pre-flow/spot timer (Not used when unit has preflow/spot timer option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
2
1
1
1
1
1
1
1
1
2
1
3
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
♦
Part of Optional Start Current/Crater Fill.
♦♦
Part of Optional Pulser.
Note: Order by model and serial number.
♦♦♦
OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 33
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-6. Panel, Front w/Components (Fig 7-1 Item 36)
Quantity
. . .
. . .
1
2
. . . . . . . . . . . . . . . .
. . . . .
. . . . . . . . . .
PL1 . . . . . .
PLG37
169 133
155 500
. . .
. . .
RECESS, handle switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LED, yellow (50Hz model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 135 635 . . . CONNECTOR & PINS, (50Hz model) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . S7 . . . . . . 046 746 . . .
NAMEPLATE, (order by model and serial number)
SWITCH, pushbutton (Fig 7-8)
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
5
6
. . . . . . . . . . . . . . . .
. . . HD1/PC4 . . .
164 347
156 313
. . .
. . .
BRACKET, mtg lem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRANSDUCER, current 300A module sply . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
7
8
. . . . PLG27 . . . .
. . . . . . . . . . . . . . . .
130 204
141 690
. . .
. . .
CONNECTOR & SOCKETS
GROMMET, scr No. 8/10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . . . .
Fig 7-4
Fig 7-5
. . .
. . .
PANEL, center w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PANEL, front upper w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . . . . . . . . . . . . 163 110 . . . UPRIGHT, base front
. . . 12 . . . . . . . . . . . . . . . . 182 125 . . . BAFFLE, front center
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
13
14
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
Fig 7-7
169 134
. . .
. . .
PANEL, front lower w/components
PANEL, door switch
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
. . . 15 . . . . . . . . . . . . . . +144 753
. . . 16 . . . . . . . . . . . . . . . . 145 784
. . .
. . .
DOOR, HF panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TAPE, adh dual lock 1.000 wide (order by ft) . . . . . . . . . . . . . . . . . . . . . .
1
1ft
. . .
. . .
17
18
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
127 363
134 327
. . .
. . .
LABEL, warning electric shock can kill
LABEL, warning general precautionary
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 19 . . . . . . . . . . . . . . . .
. . . 20 . . . . . . . . . . . . . . . .
169 136
175 952
. . .
. . .
PIN, handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
10 Fig 7-5 11
.
Hardware is common and not available unless listed.
7
Fig 7-4
9
8
2 3
Fig 7-8
4
6
5
1
12
14
19
20
18
15
16
13
Fig 7-7
17
Figure 7-6. Panel, Front w/Components
ST-149 845-D
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 34
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-7. Panel, Front Lower w/Components (Fig 7-6 Item 13)
Quantity
. . . 1 . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . . .
182 118
010 855
. . .
. . .
PANEL, HF door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RETAINER, scr No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . . 182 119 . . . PANEL, front control
. . . 4 . . . . . . . . . . . . . . . . 010 357 . . . NUT, speed No. 2 clip
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . R5 . . . . . .
. . . 6 . . . . . . . . . . . . . . . .
174 037
157 318
. . .
. . .
RHEOSTAT, WW 50W 1.5 ohm
HOLDER, HF coil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . . T4 . . . . . . 146 278 . . . COIL, HF coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
8
9
. . . . . . . . . . . . . . . .
. . Elect/Work . . .
157 317
039 047
. . .
. . .
HOLDER, HF coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TERMINAL, pwr output red (consisting of) . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
. . .
. . .
10
11
12
13
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
601 976
039 049
601 880
039 044
. . . .
. . . .
. . . .
. . . .
SCREW, 500-13 x 1.50 hexhd-pln stl
TERMINAL BOARD, red
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NUT, stl hex jam .500-13
BUS BAR, term bd
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 14 . . . . . . . . . . . . . . . . 601 879 . . . . NUT, stl hex full fnsh .500-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 15 . . . . . . . . . . . . . . . . 145 784 . . . TAPE, adh dual lock 1.000 wide (order by ft) . . . . . . . . . . . . . . . . . . . . . .
1
1ft
1
1
2
2
1
1
1
1
1
1
1
2
1
. . . 16 . . . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . . . .
182 117
000 527
. . .
. . .
PANEL, front HF control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BLANK, snap-in .875mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 18 . . . . C13,14 . . . .
. . . 19 . . . . . . . . . . . . . . . .
187 254
010 381
. . .
. . .
CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONNECTOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 20 . . . . . . GS . . . . . .
. . . 21 . . PC12,RC1 . . .
109 930
157 959
. . .
. . .
VALVE, 24VAC 2 way 1/4IPS 1/8 orf
CIRCUIT CARD, connector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
. . . 22 . . . . .
. . . 23 . . . . .
PLG34
CB1
C12
. . . . 153 501 . . . CONNECTOR & SOCKETS
. . . . .
. . . . . .
093 995
135 664
. . .
. . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT BREAKER, man reset 1P 15A 250VAC
CAPACITOR
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
. . .
24
25
. . . . . RC2 . . . . .
. . . . . . . . . . . . . . . .
604 176
097 922
. . .
. . .
RECEPTACLE, str dx grd 2P3W 15A 125V
KNOB, pointer
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 26 . . . . . . . . . . . . . . . . 602 358 . . . FASTENER, scr No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
4
1
1
1
1
1
1
1
1
1
1
7
8
5
1
3
4
6
2
26
25
24
9
11
14
13
12
9
10
23
22
21
20
15
.
Hardware is common and not available unless listed.
19
18
17
16
ST-150 189-D
Figure 7-7. Panel, Front Lower w/Components
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 35
Item
No.
Dia.
Mkgs.
S7
Part
No.
046 746
Description
Figure 7-8. Switch, Push Button (Fig 7-6 Item 4)
Quantity
. . . 1 . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . . .
059 885
018 606
. . .
. . .
BUTTON, push reset red
SPRING, compression
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . . 045 546 . . . PUSH BUTTON, w/cable and housing . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . . .
081 008
178 856
. . .
. . .
BRACKET, mtg switch PB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SWITCH, limit leaf actuating SPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
.
Hardware is common and not available unless listed.
4
1
2 3 4
1
2
3
5
9
5
5
6
6
7
ST-080 214-B
Figure 7-8. Switch, Push Button
8
ST-159 553-A
Figure 7-9. Rectifier, SCR Main
Item
No.
Dia.
Mkgs.
SR1
Part
No.
Description
Figure 7-9. Rectifier, SCR Main Right And Left
(Fig 7-1 Items 24 & 39)
Quantity
144 849 182 114
. . .
. . .
1
2
. . . PLG8 . . . .
. . . . . . . . . . . . .
115 092
605 886
. .
. .
CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WASHER, lock stl intl tooth .750
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . .
. . . 5 . . . C7,8 . . . .
605 884
031 689
. .
. .
NUT, stl hex jam .750-16
166 667 . . CLAMP, spring thyristor
CAPACITOR, rectifier
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
2
. . . .
. . . 5 . . . C9,10
. . . 6 . . SCR1,2
. . .
. . .
031 689
119 371
. .
. .
CAPACITOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
THYRISTOR, scr 300A 300V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 6 . . SCR3,4 . . .
. . . 7 . . . . . . . . . . . . .
119 371 . . THYRISTOR, scr 300A 300V
028 516 . . PIN, spring CS .125 x .250
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . .
173 714 . . CLAMP, thyristor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 8 . . . . . . . . . . . . .
. . . 9 . . . . D1 . . . . .
. . . . . . . . . . . . . . . . . . .
037 956
168 898
. .
. .
DIODE, rect 275A 300V SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
THERMOSTAT, NC open 125F close 105F
1
. . . . . . . . . . . . . . . . . . . . . . . . .
1
2
2
1
1
1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-354 Page 36
Warranty Questions?
Call
1-800-4-A-MILLER for your local
Miller distributor.
Your distributor also gives you ...
Service
You always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
Support
Need fast answers to the tough welding questions?
Contact your distributor.
The expertise of the distributor and Miller is there to help you, every step of the way.
Effective January 1, 2000
(Equipment with a serial number preface of “LA” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied.
LIMITED WARRANTY – Subject to the terms and conditions below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its original retail purchaser that new Miller equipment sold after the effective date of this limited warranty is free of defects in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
Within the warranty periods listed below, Miller will repair or replace any warranted parts or components that fail due to such defects in material or workmanship. Miller must be notified in writing within thirty (30) days of such defect or failure, at which time Miller will provide instructions on the warranty claim procedures to be followed.
Miller shall honor warranty claims on warranted equipment listed below in the event of such a failure within the warranty time periods. All warranty time periods start on the date that the equipment was delivered to the original retail purchaser, or one year after the equipment is sent to a North American distributor or eighteen months after the equipment is sent to an
International distributor.
1.
5 Years Parts – 3 Years Labor
* Original main power rectifiers
* Inverters (input and output rectifiers only)
2.
3 Years — Parts and Labor
* Transformer/Rectifier Power Sources
* Plasma Arc Cutting Power Sources
* Semi-Automatic and Automatic Wire Feeders
* Inverter Power Supplies
* Intellitig
* Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the engine manufacturer.)
3.
1 Year — Parts and Labor
* DS-2 Wire Feeder
* Motor Driven Guns (w/exception of Spoolmate
185 & Spoolmate 250)
* Process Controllers
* Positioners and Controllers
* Automatic Motion Devices
* RFCS Foot Controls
* Induction Heating Power Sources
* Water Coolant Systems
* HF Units
* Grids
* Maxstar 140
* Spot Welders
* Load Banks
* Miller Cyclomatic Equipment
* Running Gear/Trailers
* Plasma Cutting Torches (except APT & SAF
Models)
* Field Options
(NOTE: Field options are covered under True
Blue
for the remaining warranty period of the product they are installed in, or for a minimum of one year — whichever is greater.)
4.
6 Months — Batteries
5.
90 Days — Parts
* MIG Guns/TIG Torches
* Induction Heating Coils and Blankets
* APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
* Remote Controls
* Accessory Kits
* Replacement Parts (No labor)
* Spoolmate 185 & Spoolmate 250
* Canvas Covers
Miller’s True Blue
Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips, cutting nozzles, contactors, brushes, slip rings, relays or parts that fail due to normal wear.
2.
Items furnished by Miller, but manufactured by others, such as engines or trade accessories. These items are covered by the manufacturer’s warranty, if any.
3.
Equipment that has been modified by any party other than Miller, or equipment that has been improperly installed, improperly operated or misused based upon industry standards, or equipment which has not had reasonable and necessary maintenance, or equipment which has been used for operation outside of the specifications for the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Miller’s option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer’s risk and expense. Miller’s option of repair or replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION, MIGHT ARISE BY IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may be available, but may vary from province to province.
miller_warr 7/00
Owner’s Record
Please complete and retain with your personal records.
Serial/Style Number Model Name
Purchase Date
Distributor
Address
City
State
(Date which equipment was delivered to original customer.)
Zip
For Service
Call 1-800-4-A-Miller or see our website at www.MillerWelds.com
to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for: Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information and Parts)
Circuit Diagrams
Welding Process Handbooks
File a claim for loss or damage during shipment.
Contact the Delivering Carrier for:
For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department.
PRINTED IN USA
2000 Miller Electric Mfg. Co. 6/00
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
International Headquarters–USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
European Headquarters –
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066 www.MillerWelds.com

Public link updated
The public link to your chat has been updated.
Advertisement