Panasonic NR-BX418GW, NR-BX418VS, NR-BX418XS, NR-BX41BVW, NR-BX41BXS, NR-BX468GK, NR-BX468GW, NR-BX468VS, NR-BX468XS, NR-BX46BVW Service Manual
Panasonic NR-BX46BVW is a technologically advanced refrigerator that offers excellent cooling performance and a user-friendly experience. Featuring ECONAVI technology, this refrigerator intelligently adjusts cooling based on usage patterns, saving energy without compromising on performance. With its various temperature control modes, you can customize the cooling to suit your specific needs. The quick freezing function ensures rapid freezing of food items, preserving their freshness and nutrients. The refrigerator also boasts a spacious interior with adjustable shelves and compartments, providing ample storage for your groceries. Its elegant design and sleek finish make it a stylish addition to any kitchen.
Advertisement
Advertisement
Order No. PAPTH151201CE Revision : Jun.2016 Service Manual Refrigerator NR-BX418XS, NR-BX418VS, NR-BX418GW NR-BX468XS, NR-BX468VS, NR-BX468GW NR-BX41BXS, NR-BX46BXS, NR-BX41BVW NR-BX46BVW, NR-BX418GK, NR-BX468GK Product Colour White(VW)/(GW) Shinning Silver(VS) Stainless Colour(XS) Black(GK) Destination NR-BX468X NR-BX41B NR-BX46B NR-BX468G NR-BX418V NR-BX468V NR-BX41B NR-BX46B NR-BX418GK NR-BX468GK Thailand, Vietnam Malaysia, Philippines Hong Kong, Singapore, RBD Indonesia, India, Australia/ New Zealand CFCs have been used in refrigerant as refrigerator and the insulation materials for many years. But it is now known that these compounds which once seemed so ideal for use as cleaning agents and in refrigeration systems, destroy the earth’s ozone layer as a result, an international body decided on a total worldwide ban of harmful CFCs by the end of 1995. WARNING The service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt within this service information by anyone else could result in serious injury or death. IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer. © Panasonic Appliances (Thailand) Co., Ltd. 2016. All rights reserved. Unauthorized copying and distribution is a violation of law. NR-BX418/NR-BX468/NR-BX41B/NR-BX46B CONTENT Page 1. SAFETY CAUTIONS FOR REPAIRING 1.1 Warning 1.2 Cautions 2. SPECIFICATION AND COMPONENTS 2.1 NR-BX418VS, NR-BX418VW, NR-BX418XS, NR-BX418GW, NR-BX41BVN, NR-BX418BXS, NR-BX418GK 2.2 NR-BX468VS, NR-BX468VW, NR-BX468XS, NR-BX468GW, NR-BK46BV, NR-BX468BX, NR-BX468GK 3. PERFORMANCE DATA 3.1 NR-BX418XS, NR-BX46BXS, NR-BX418GW/GK (AT 32±1 °C) 3.2 NR-BX418VS, NR-BX418VW, NR-BX41BVW (AT 32±1 °C) 3.3 NR-BX468XS, NR-BX46BXS, NR-BX468GW/GK (AT 32±1 °C) 3.4 NR-BX468VS, NR-BX468VW (AT 32±1 °C) 4. DISPLAY SPECIFICATION 5. SELF PROTECTING FUNCTION 5.1 Protection for IC 5.2 Protection for compressor locked 5.3 Protection for power supply droping 6. SELF DIAGNOSING FUNCTION 7. TEMPERATURE CONTROL 7.1 TEMPERATURE CONTROL NR-BX418XS, NR-BW418GW/GK, NR-BX41BXXS, NR-BX46BXS, NR-BX468GW/GK 7.2 TEMPERATURE CONTROL NR-BX418V, NR-BX468V, NR-BX41BVW, NR-BX46BVW 7.3 TEMPERATURE CONTROL (FINE ADJUSTMENT MODE) 8. OPERATION 8.1 QUICK FREEZING 8.2 ECONAVI OPERATION 9. REFRIGERATOR INSRUCTION GUIDELINE 10. TROUBLESHOOTING GUIDE 10.1 Not cool at all [ Both PC & FC (compressor does not operate) 10.2 Cool, not enough [ both PC & FC (compressor operate) ] 10.3 ECONAVI operation doesn't work (PC/FC/IC cooling condition is normal) 11. SCHEMATIC DIAGRAM 11.1 Wiring Diagram : NR-BX418XS, NR-BX468XS, NR-BX418GW, NR-BX468GW NR-BX41BXS, NR-BX46BXS, NR-BX418GK, NR-BX468GK 11.2 Wiring Diagram : NR-BX418VS, NR-BX418VW, NR-BX468VS, NR-BX468VW NR-BX41BVW, NR-BX46BVW 12. DISASSEMBLY INSTRUCTION 12.1 COVER LED LAMP / PAS-BW468(LED) 12.2 PAS-OPERATED CONTROL (DOOR) FOR G TYPE 12.3 PAS-OPERATED CONTROL (DOOR) FOR X TYPE 12.4 COVER DAMPER PC AS / FAN MOTOR 13. SERVICE INFORMATION 13.1 Dryer set (Kit) R600a 13.2 Insert the D-joint Pipe (Capilary tube into Dryer) 13.3 Notes of wire connected work (Scotch Lock) 14. PART LIST EXPLODED VIEW AND REPLACEMENT PARTS LIST 14.1 PART EXPLODED VIEW : BODY 14.2 PART EXPLODED VIEW : DOOR 14.3 PART EXPLODED VIEW : PACKING 14.4 REPLACEMENT PARTS LIST NR-BX418, NR-BX41B 14.5 REPLACEMENT PARTS LIST NR-BX468, NR-BX46B DETAIL CHANGE NOTICE -2- 3 4 5 6 6 6 6 6 7 8 8 9 10 11 12 12 12 13 14 14 14 15 16 16 17-18 19 20 20 21 22 22 23 24 25 26 26 27 28 29 29 30 31 32-34 35-37 37 NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 1. SAFETY CAUTIONS FOR REPAIRING When you repair the refrigerator, please kindly take care for the following cautions. 1.1 WARNING Before repairing unit, unplug supply cord ● Before you repair the refrigerator, please unplug the supply cord. Use authentic parts when repairing ● When you replace the parts, please use authentic parts to replace defective parts. Caution during brazing ● When you use touch for brazing, please ensure ventilation. Otherwise, you will be poisoned by carbon monoxide. Pay attention to using refrigerant ● If refrigerant touches fire, the gas becomes poisonous gas. Pay attention to getting electricity shock ● When you check the voltage of terminal, please do not touch the electricity part terminal. ● When you replace the parts, please wait for 3 minutes at least for discharging capacitor. Check safety after repairing ● Check the screws, parts, lead wires to take in place. ● Check the repairing portion whether circumferential parts are damaged or not. ● Check insulation resistance between supply plug and earth. ● When install refrigerator, check condition of supply cord and plug. ● Wipe off the dust on plug. ● Cutting and seal the electric device carefully. 1.2 CAUTIONS Watch the hot parts ● During operation and after operation, compressor and pipes are hot. ● Also, under these condition, heater are hot. ● Do not burn your fingers when you touch it. Pay attention to refrigerant ● Do not touch liquid refrigerant. Otherwise your hands may be burnt. Pay attention to edge of parts ● Otherwise, your fingers may be cut. Pay attention to fins of evaporator and condenser ● Otherwise, your fingers may be cut. Before transportation, adjust the bolt ● Otherwise, the floor may be damaged. Do not touch the pipe after brazing ● Otherwise, your hands may be burnt. -3- NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 2. SPECIFICATION AND COMPONENTS 2.1 NR-BX418VS, NR-BX418VW, NR-BX418XS, NR-BX418GW, NR-BX41BVN, NR-BX418BXS, NR-BX418GK Model NR-BX418VS Destination Code Attached Model Plug Power Source NR-BX41B NR-BX418XS Thailand Vietnam Indonesia RBD India TH VN 1D WA X1 AU VN MY C3P C2P C2P C2P B3P K3P C2P S3P 220V/50Hz 220V/50Hz 220-240V/50Hz 220V/50Hz 230V/50Hz Australia/New Zealand Vietnam Malaysia Philippines 240V/50Hz 220V/50Hz 240V/50Hz NR-BX418GW/GK Hong Kong Australia PH HK AU VN SG MY 1D HK A2P S3P K3P C2P S3P S3P C2P S3P 230V/60Hz Vietnam Singapore Malaysia Dimension External 407L Temperature Control (FC : 134L, PC : 273L) Width(mm) 685 Depth(mm) 689 Height(mm) 1624 FC Electronic control (PCB) PC Electrical damper NSBD060AA1 Net Weight (Kg) 72 Kg Defrosting Full-automatic heater defrost with PCB control Exterior Finish (cabinet / door) PCM colour - Polyester paint coating / (Polyester painting steel / Painting glass ) Inner Liner Vacuum Formed ABS resin Insulation Cyclopentane (cabinet and door) 2.2 Sealed Unit Compressor ERI100E13DGH Condenser Copper tube Type Pressure Reducing Device Type Capillary Tube Evaporator Type Refrigerant Type R600a Charge 70 ± 5g I/D x Length Ø 0.77mm. X 3375mm. 2ND Pressure Lubricating Oil 0.622MPa Fin And Tube Type Freol S - 10 Charge 215 ± 5ml 2.3 Electric Part Door Switch Type D3D-121 (S.P. - S.T.) Rating Fan Motor 250V / 0.5A Type 11338JE09KBA Rating DC 9V / 0.1A / 0.9W Applied Fan Light Irradiation Device (PC) Type Heating Device For Defrosting Type Defrost Thermal Fuse Type Ø 110mm. prop fan (Box Type) LED Lamp PCB Rating 12V / 100mA MM6-8V88 Rating 220V / 161W Micro Temp. Rating Defrost Sensor (DFC) 250V / 10A / 73°C Type NTC Rating B = 3819K ± 2% R10 = 3.899KΏ ± 3% FC Sensor (FCC) Type NTC Rating B = 3850K ± 2% R-20 = 18.9KΏ ± 1.8% Ambient Temperature Sensor (ATC) Type NTC Control Board BX418V/BX41BVW PAS-CONTROL PCB ( V type ) BX418XS/BX468G PAS-CONTROL PCB ( X/G type ) Rating B = 3435K ± 1% R25 = 10.0KΩ ± 3% Defrosting Control (Electronic PCB Control) (1)Ambient Temp. over 34°C 8h (2)Ambient Temp. 23°C ~ 33°C 8h (3)Ambient Temp. under 22°C 13h (4)Power on 4h (Rated time) Overload Protector MM3-20DCW -4- Hong Kong 220V/50Hz 240V/50Hz 220V/50Hz 230V/50Hz 240V/50Hz 220-240V/50Hz 220V/50Hz 2.1 Specification Capacity (Total Net Volume) Indonesia NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 2.2 NR-BX468VS, NR-BX468VW, NR-BX468XS, NR-BX468GW, NR-BK46BV, NR-BX468BX, NR-BX468GK Model NR-BX468VS Destination NR-BX46B NR-BX468XS Thailand Vietnam Indonesia India Australia/New Zealand Thailand Vietnam Code Attached Model TH VN 1D X1 AU TH VN MY SG PH Plug Power Source C3P C2P C2P B3P K3P C3P C2P S3P S3P A2P 220V/50Hz 220V/50Hz 220-240V/50Hz 230V/50Hz 240V/50Hz NR-BX468GW/GK RBD Australia/New Zealand Thailand Vietnam Malaysia Hong Kong HK WA AU TH VN MY HK SG S3P C2P K3P C3P C2P S3P S3P S3P Malaysia Singapore Philippines Hong Kong 220V/50Hz 220V/50Hz 240V/50Hz 230V/50Hz 230V/50Hz 220V/50Hz 220V/50Hz 240V/50Hz 2.1 Specification 450L Capacity (Total Net Volume) Dimension External Temperature Control (FC : 134L, PC : 316L) Width(mm) 685 Depth(mm) 698 Height(mm) 1764 FC Electronic control (PCB) PC Electrical damper NSBD060AA1 Net Weight (Kg) 74 Kg Defrosting Full-automatic heater defrost with PCB control Exterior Finish (cabinet / door) PCM colour - Polyester paint coating / (Polyester painting steel / Painting glass ) Inner Liner Vacuum Fomed ABS resin Insulation Cyclopentane (cabinet and door) 2.2 Sealed Unit Compressor ERI100E13DGH Condenser Copper tube Type Pressure Reducing Device Type Capillary Tube Evaporator Type Refrigerant Type R600a Charge 70 ± 5g I/D x Length Ø 0.77mm. X 3375mm. 2ND Pressure Lubricating Oil 0.622MPa Fin And Tube Type Freol S - 10 Charge 215 ± 5ml 2.3 Electric Part Door Switch Type D3D-121 (S.P. - S.T.) Rating Fan Motor 250V / 0.5A Type 11338JE09KBA Rating DC 9V / 0.1A / 0.9W Applied Fan Light Irradiation Device (PC) Type Heating Device For Defrosting Type Defrost Thermal Fuse Type Ø 110mm. prop fan (Box Type) LED Lamp PCB Rating 12V / 100mA MM6-8V88 Rating 220V / 161W Micro Temp. Rating Defrost Sensor (DFC) 250V / 10A / 73°C Type NTC Rating B = 3819K ± 2% R10 = 3.899KΏ ± 3% FC Sensor (FCC) Type NTC Rating B = 3850K ± 2% Ambient Temperature Sensor (ATC) Type NTC Control Board BX468V/BX46BVW PAS-CONTROL PCB ( V type ) BX468XS/BX468G PAS-CONTROL PCB ( X/G type ) Rating B = 3435K ± 1% R25 = 10.0KΩ ± 3% Defrosting Control (Electronic PCB Control) (1)Ambient Temp. over 34°C 8h (2)Ambient Temp. 23°C ~ 33°C 8h (3)Ambient Temp. under 22°C 13h (4)Power on 4h (Rated time) Overload Protector MM3-20DCW -5- 220V/50Hz 220V/50Hz 240V/50Hz 220V/50Hz Singapore 230V/50Hz NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 3. PERFORMANCE DATA 3.1 NR-BX418XS, NR-BX46BXS, NR-BX418GW/GK (AT 32 ± 1 °C) ( ECO - OFF ) COLDEST TEMPERATURE CONTROL Mean Fresh Food Compartment Temp. t3 (°C) ( ECO - ON ) WARMEST MEDIUM 1.0±2.5 3.0±2.5 4.5±2.5 6.0±2.5 Mean Freezer Load Temp. (°C) -22.0±2.5 -21.0±2.5 -19.5±2.5 -16.0±2.5 Vegetable Crisper Temp. (°C) - 3.5±2.5 4.5±2.5 - PC Door Shelf Upper Tem. (°C) - 7.5±2.5 9.0±2.5 - Egg Tray Temp. (°C) - 4.0±2.5 5.0±2.5 - PC Door Shelf Bottom Temp. (°C) - 3.5±2.5 5.0±2.5 - Chilled Case Temp. (°C) - -3.0±1.5 -3.0±2.5 - Running Ratio (%) 65±15 60±15 60±15 50±15 3.2 NR-BX418VS, NR-BX418VW, NR-BX41BVW (AT 32 ± 1 °C) COLDEST TEMPERATURE CONTROL Mean Fresh Food Compartment Temp. Mean Freezer Load Temp. t3 (°C) (°C) ( ECO - OFF ) ( ECO - ON ) MEDIUM WARMEST 1.0±2.5 3.0±2.5 4.5±2.5 5.0±2.5 -23.0±2.5 -21.0±2.5 -19.5±2.5 -16.0±2.5 Vegetable Crisper Temp. (°C) - 3.5±2.5 3.5±2.5 - PC Door Shelf Upper Tem. (°C) - 7.5±2.5 7.5±2.5 - Egg Tray Temp. (°C) - 4.0±2.5 4.0±2.5 - PC Door Shelf Bottom Temp. (°C) - 3.5±2.5 3.5±2.5 - Chilled Case Temp. (°C) - 1.0±1.5 1.0±2.5 - Running Ratio (%) 65±15 60±15 60±15 50±15 3.3 NR-BX468XS, NR-BX46BXS, NR-BX468GW/GK (AT 32 ± 1 °C) COLDEST TEMPERATURE CONTROL Mean Fresh Food Compartment Temp. Mean Freezer Load Temp. t3 (°C) (°C) ( ECO - OFF ) ( ECO - ON ) MEDIUM WARMEST 1.0±2.5 3.0±2.5 4.5±2.5 5.5±2.5 -23.0±2.5 -21.0±2.5 -19.5±2.5 -16.0±2.5 Vegetable Crisper Temp. (°C) - 3.5±2.5 4.5±2.5 - PC Door Shelf Upper Tem. (°C) - 4.0±2.5 5.5±2.5 - Egg Tray Temp. (°C) - 3.0±2.5 5.0±2.5 - PC Door Shelf Bottom Temp. (°C) - 4.0±2.5 5.0±2.5 - PF Case Temp. (°C) - -3.0±1.5 -3.0±2.5 - Running Ratio (%) 70±15 65±15 60±15 50±15 3.4 NR-BX468VS , NR-BX468VW (AT 32 ± 1 °C) COLDEST TEMPERATURE CONTROL Mean Fresh Food Compartment Temp. t3 (°C) ( ECO - OFF ) ( ECO - ON ) MEDIUM WARMEST 1.0±2.5 3.0±2.5 4.5±2.5 5.5±2.5 Mean Freezer Load Temp. (°C) -22.5.0±2.5 -21.0±2.5 -19.5±2.5 -16.0±2.5 Vegetable Crisper Temp. (°C) - 3.5±2.5 4.5±2.5 - PC Door Shelf Upper Temp. (°C) - 4.0±2.5 4.0±2.5 - Egg Tray Temp. (°C) - 3.0±2.5 3.0±2.5 - PC Door Shelf Bottom Temp. (°C) - 4.0±2.5 4.5±2.5 - Chilled Case Temp. (°C) - 1.0±1.5 1.0±2.5 - Running Ratio (%) 70±15 65±15 60±15 50±15 -6- NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 4. DISPLAY SPECIFICATION NR-BX418VS, NR-BX41BVW, NR-BX418XS, NR-BW418GW/GK, NR-BX468XS, NR-BX46BXS, NR-BX468GW/GK PROCESS INSPECTION DISPLAY ECONAVI Quick freezing LED light Fridge control button Prime fresh control button Freezer control button IN-PROCESS INSPECTION START CONDITION Operate the following control within 3 sec. , within 30 sec., after power-on while PC door are open. Push Door switch more than 3 time but not over 10 time END CONDITION 1. Push Door switch more than 3 time but not over 10 time ( Manual defrost ) 2. After 4 hours ( Defrost start ) CONTENTS FOR CONTROL COMP. : R5 (52 rps ) FC FAN : High speed HEATER : Defrost heater off LED : ECONAVI LED has only for model which have operation panel BRINKING (ON_1sec/OFF_1sec ) MANUAL DEFROST Push Door switch more than 3 time but not over 10 time AUTO DIAGNOSIS JUDGEMENT During IN-PROCESS INSPECTION NOISE MODE For 45 sec., of the start of IN-PROCESS INSPECTION CONTENTS INSPECTION OF TEMP. JUDGEMENT Indicate AUTO DIAGNOSIS in which case abnormal condition. COMP. : R5 (52 rps ) For 30 min., of the start of IN-PROCESS INSPECTION Normal or abnormality is displayed according to the range of drop of FCC ALL FREEZER LED LIGHTING……….GOOD ALL FREEZER LED BRINKING……….BAD INSPECTION OF ILLUMINANCE SENSOR JUDGEMENT During IN-PROCESS INSPECTION After 1 min., of the start of IN-PROCESS INSPECTION Abnormality is judged according to variation width of input voltage of illuminance sensor. ECONAVI LED EXTINCTION………..GOOD ECONAVI LED BRINKING……………..BAD -7- NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 5. SELF PROTECTING FUNCTION 5.1 Protection for IC 1 Does IC receive IPM protect signal? NO • Normal operating. YES 2 IC orders to stop compressor for 10 min. 3 After 10 min., does PCB check if IPM protect signal is normal? NO • IC continues to stop compressor until 1 hour. • IC indicates Self Diagnosing sign. YES • IC continues to stop compressor until 1 hour. • IC indicates Self Diagnosing sign. YES 4 IC cancels to stop compressor.signal is Normal operating? 5 After restarting, does “Stop compressor” occure 10 times within 2 min? NO 6 IC cancels to stop compressor. Normal operating? 8 Does system protection cycle for 333 times? 7 After 1 hour. YES 9 IC order to stop compressor completely. SYSTEM PROTECT CONTROL CYCLE 1st time SYSTEM PROTECT CONTROL CYCLE STOP COMPRESSOR 333rd time OPERATE each 7min X 10 times COMPRESSOR 1hour STOP -8- OPERATE each 7min X 10 times NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 5.2 Protection for compressor locked 1 • After starting 2 sec., does IC detect rpm < 5r/sec.? • After starting from 2-10 sec., does PCB detect rpm over 120r/sec.? NO • Normal operating. YES 2 IC orders to stop compressor for 10 min. 3 IC cancels to stop compressor after 10 min. 4 After restarting, does “Stop compressor” occure 10 times within 2 min.? 5 IC cancels to stop compressor. Normal operating? • IC continues to stop compressor until 1 hour. • IC indicates Self Diagnosing sign. YES 6 After 1 hour. NO 7 Does system protection cycle for 333 times? NO YES 8 IC order to stop compressor completely. SYSTEM PROTECT CONTROL CYCLE 1st time SYSTEM PROTECT CONTROL CYCLE STOP COMPRESSOR 333rd time OPERATE each 7min X 10 times COMPRESSOR 1hour STOP -9- OPERATE each 7min X 10 times NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 5.3 Protection for power supply droping 1 Does power supply voltage drop as condition > 0.1 sec. and < 160V AC? NO • Normal operating. YES 2 IC orders to stop compressor for 10 min. 3 After 10 min., does PCB check power supply voltage if it is > 180V AC? NO • IC continues to stop compressor until 1 hour. • IC indicates Self Diagnosing sign. YES • IC continues to stop compressor until 1 hour. • IC indicates Self Diagnosing sign. YES 4 IC cancels to stop compressor. Normal operating? 5 After restarting, does “Stop compressor” occure 10 times within 2 min? NO 6 IC cancels to stop compressor. Normal operating? 7 - 10 - After 1 hour. NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 6. SELF DIAGNOSING FUNCTION When abnormal is cased in the refrigeator, the sign is displayed on LED as below chart How to use “ Self diagnosing “ function ( Door control model ) 1. Opening PC door push “ Fridge button “ more then 5 sec. 2. After blinking sec., each LED show as below. 3. “ Self diagnosing “ function will be automatically cancel after 7 min., from start operation. How to use “ Self diagnosing “ function ( Door control model ) 1. Opening PC door and Door switch depressed push “ Fridge button “ more then 5 sec ( Initially , all LED will be on for 3 sec ) 2. After blinking at see, each LED show as below. 3. “ Self diagnosing “ function will be automatically cancel after 7 min., from start operation. No. Corresponding diagnostic code Quick Freezing (diagnostic code will not be displayed) LED Failure mode Detection of HC refrigerant leakage Control LED Min. H36 (low-pressure leak) Detection of HC refrigerant leakage Max. ● ● H35 (high-pressure leak) Disconnection or short circuit in ATC thermistor H07 (defect in ATC thermistor) Disconnection or short circuit in DFC thermistor H05 (defect in DFC thermistor) Disconnection or short circuit in FCC thermistor H01 (defect in FCC thermistor) ● Disconnection or short circuit in PCC thermistor H02 (defect in PCC thermistor) ● Disconnection or short circuit in PFC thermistor H03 (defect in PFC thermistor) ● Defect in FC defrost heater Mid. ● ● ● ● H31(defect in FC defrost heater) ● H40 (IPM lock protection) Defect in INV comp. H41(undervoltage protection) ● ● ● H52(overvoltage protection) Defect in PCB Defect in illumination sensor Normal H50 (communication error) ● H51 (error in EEPROM) H64 (defect in illumination sensor) -- ● ● ● ● ● ● ● [ ● ] : Go out [ ● ] : Light up [ ] : Flash (0.16s ON / 0.16s OFF) - 11 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 7. TEMPERATURE CONTROL 7.1 TEMPERATURE CONTROL NR-BX418XS, NR-BW418GW/GK, NR-BX41BXXS, NR-BX46BXS, NR-BX468GW/GK Lower than Med by 2°C ~ 3°C “Max” “Fridge” Approx. 1°C ~ 6°C “Med” Higher than Med by 2°C ~ 3°C “Min” Lower than Med by 2°C ~ 3°C “Max” Approx. -5°C ~ -1°C “Med” “Prime Fresh” Higher than Med by 2°C ~ 3°C “Min” Approx. -1°C ~ 3°C The temperature can be adjusted for Min - Max levels. Press or or to adjust temperature in Fridge, Prime Fresh or Freezer room respectively. Lower than Med by 2°C ~ 3°C “Max” “Freezer” Approx. -23°C ~ -17°C “Med” “Min” Higher than Med by 2°C ~ 3°C 7.2 TEMPERATURE NR-BX418V, NR-BX468V, NR-BX41BVW, NR-BX46BVW The temperature can be adjusted for Min-Max levels. Press to adjust temperature in Fridge Room. to adjust temperature in Freezer room and press Fridge Room temperature control “Max” Lower than Med by 2°C ~ 3°C “Med” Approx. 1°C ~ 6°C “Min” Higher than Med by 2°C ~ 3°C Freezer Room temperature control “Max” Lower than Med by 2°C ~ 3°C “Med” Approx. -23°C ~ -17°C “Min” Higher than Med by 2°C ~ 3°C Temperature in Chill case is automatically set at approximately -1°C ~3°C Remark While operating the refrigerator for the first time, after connecting the plug, adjust the temperature to "Med" position of each control and leave it for 24 hours for the effective cooling operation. After that, adjust the temperature as you prefer. If you want to save the energy, do not adjust the temperature lower than the actual operating condition. - 12 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 7.3 TEMPERATURE CONTROL (FINE ADJUSTMENT MODE) This refrigerator is specially designed for appropriate use, which can adjust the temperature level to detailed 9 levels with the following details. How to operate the “9 levels” mode For the Freezer room 1. Set LED display to “Min” with the “Freezer” button. 2. Press and hold the “Freezer” button (for a few seconds) until the LED display return to show at “Min” position. 3. Set “9 levels” mode following below table mentioned by pressing the “Freezer” button. ■ LED Display table (Model: NR-BX418XS, NR-BW418GW/GK, NR-BX41BXS, NR-BX46BXS, NR-BX468GW/GK) Cooling Level Minimum 1 Step Maximum 2 3 4 5 6 7 8 9 LED DISPLAY Lighting Blinking Not lighting ■ LED Display table (Model: NR-BX418V, NR-BX468V, NR-BX41BVW, NR-BX46BVW) Cooling Level Minimum 1 Step Maximum 2 3 4 5 6 7 LED DISPLAY Lighting Blinking Not lighting For the Fridge room Operate above 1 ~ 3 steps with pressing “Fridge” button instead of “Freezer” button. To reset the setting “9 levels” mode Repeat step 1 and 2, then the refrigerator return to normal operation mode. Remark: Temperature control varies depends on the changing of environment and food storage quantity. - 13 - 8 9 NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 8. OPERATION 8.1 QUICK FREEZING How to operate the “Quick Freezing” mode ● Press the button “Freezer” until Blue light LED turns on. “Quick Freezing” mode starts after 5 seconds. ● The system will stop operating automatically when it runs for 120 mins (as ambient temperature is below 25°C) or 150 mins (as ambient temperature is above 25°C) and return to normal mode (Blue light LED turns off.) Remarks : ● If you want to stop the operation immediately, press and hold the button “Freezer” until Blue light LED turns off. ● Blue light LED flashing means that the defrosting system is now working "Quick Freezing" mode will start right after the defrosting operation is finished. ● Freezer temp. control does not operate during “Quick Freezing” mode. 8.2 ECONAVI OPERATION Model : NR-BX418XS, NR-BW418GW/GK, NR-BX46BXS, NR-BX46BXS, NR-BX468GW/GK Detect opening and closing of door and brightness around refrigerator, and automatically controls operation to save energy1. ECONAVI lamp is on during ECONAVI operation ● This refrigerator will learn the lifestyle patterns of your family from opening and the time periods of infrequent use to perform ECONAVI operation. ECONAVI lamp Remark : ● The refrigerator learns your lifestyle pattern from the previous 3 weeks, and uses what it has learned from the Light intensity sensor 4th week onwards. Therefore, the ECONAVI lamp "ON/ OFF” pattern may change from the 4th week onwards. ● The brightness of the lamp is lowered approximately 5 minutes after the lamp turns on. Setting for enabling ECONAVI operation ● ECONAVI operation is enabled automatically only when the temperature control of the freezer compartment are set to “Med”. (However, ECONAVI does not operate while quick freezing is operating.) ● It is not possible to forcefully start ECONAVI operation. Remark : 1 Effectiveness differs depending on the ambient temperature, ambient brightness, number of times and when doors are opened and closed, and state in which food is stored. Model : NR-BX418V, NR-BX468V, NR-BX41BVW, NR-BX46BVW This model also has ECONAVI mode, but it does not feature ECONAVI lamp and light intensity sensor. - 14 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 9. REFRIGERATOR INSTRUCTION GUIDELINE 1. Do not open the refrigerator frequently or leave it open for a long time. This is to prevent water dripping inside the refrigerator which will cause the waste of coolness and consumpting of energy. 2. Do not refrigerate unnecessary items or hard-to-rot foodstuff such as pumpkin, shallot, garlic, potato as it will make the refrigerator to work over load and waste the storage space without necessity. 3. Adjust the temperature according to the actual operating condition for energy saving. 4. Do not refrigerate the bottles bigger than the door shelf or the tray as the door will not close completely, which will cause the leakage of coolness. 5. Frequently check the door opening seal, it must be closed to the refrigerator’s body completely. Do not leave the seal dirty or damaged or deteriorated as the coolness will leak and will cause the consumption of the energy without necessity. 6. If you will not be at home for several days or there are nothing refrigerated in the refrigerator, the plug should be disconnected for energy saving. In this case, clean the refrigerator and leave it half-open to prevent bad odor. 7. Clean the drain tray located over the compressor at the back of the refirgerator every 3 months to prevent the odor generated from humidity. 8. Energy saving dryer pipes and heating pipes embedded around the refrigerator cabinet are helping to prevent “Condensation” on the outer surface of the cabinet without consuming energy. This will make the outer wall of the refrigerator get warm and that is not a malfunction. 9. Drinking water bottles, beverage bottles such as soft drinks and fruit juices should be sealed closely to prevent odor gets into the bottles. - 15 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 10. TROUBLESHOOTING GUIDE 10.1 Not cool at all [ Both PC & FC (compressor does not operate) ] 1 Does room light turn on? NO • Check power supply. Ex. Connect power cord in inlet Ex. Check ELCB • Defect of over load relay. Ex. Does fuse blow? • Check control PCB. Ex. Does fuse blow? Ex. Defect of IC, Diode, etc. NO • Defect of control PCB. • Defect PC door switch. YES • Defect of control PCB. • Communication error YES • Defect of control PCB. • Abnormal connecting of compressor. • Compressor lock. • Chock. • Leakage. • Droping voltage of power supply. • Rising voltage of power supply. YES 2 Pushing PC door switch and room light turns off, and after release PC door switch, does room light turn on? YES 3 To start self diagnosing function by opening PC door and FC door and pushing “Quick Freezing” SW for 5 seconds. 4 Does “ECONAVI Led” and “Quick Freezing” blink? NO 5 Does the “ECONAVI Led” turn on and “Quick Freezing” blinking? NO 6 Does the “ECONAVI Led” turn off and “Quick Freezing” blink? YES • Break FC thermistor. • Poor connection between FC thermistor and PCB. NO 7 Does the “ECONAVI Led” turn off, “Quick Freezing” turn off and “Freezer Control” LED “MAX” blink? YES • Gas leakage at high pressure side. • Poor compression.PCB. • Defect of control PCB. NO 8 Does the “ECONAVI Led” turn off, “Quick Freezing” turn off and “Freezer Control” LED “MIN” blink? YES • Gas leakage at low pressure side. • Defect of control PCB. NO • Faulty compressor motor. • Compressor lock. - 16 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 10.2 Cool, not enough [ Both PC & FC (compressor operates) ] To confirm when compressor is operating. When FC door opens and FC door 1 SW pushes, does cold air spout out from exhaust? • Defect of FC fan motor. • Poor connection between FC fan motor and IC 1 on PCB. • Defect of FC door SW. NO YES When PC door opens and PC door 2 SW pushes, does cold air spout out from exhaust? NO • Defect of damper. • Defect of PC door SW. YES To start self diagnosing function by opening PC door and FC door and 3 pushing “Quick Freezing” SW for 5 seconds. 4 Does “ECONAVI Led” and “Quick Freezing” turn on? • Defect of FC fan motor. • Poor connection between FC fan motor and IC 1 on PCB. YES NO 4 Does “ECONAVI Led” turn off and “Quick Freezing” blinking? • Break of FCC thermistor. • Poor connection between FCC thermistor and IC 1 on PCB. • Abnormal of spec of DFC thermistor. * Resistor of thermistor is bigger as like as 5.9 - 6.5 K at 0°C YES NO 5 Does “ECONAVI Led” turn off and “Quick Freezing” turn on? YES 6 YES NO 7 Does “ECONAVI Led” turn off and “Quick Freezing” turn off? YES 8 Does thermal NO fuse blow out? • Short of DFC thermistor. • Poor connection between DFC thermistor and IC 1 on PCB. • Break of DFC thermistor. • Poor connection between FFC thermistor and IC 1 on PCB. • Break of DFC thermistor. • Defect of PCB as like as defect of relay, etc. YES NO Does “ECONAVI Led” and “Quick 9 Freezing” blink? Does thermal NO fuse blow out? • Termal fuse blows. • Abnormal of spec of DFC thermistor. * When resistor of thermistor is bigger as like as 6.1 - 6.7K at 0°C, there is some case to blow thermal fuse out due to becoming defrost time longer. • Defect of communication circuit and EEPROM circuit of control PCB. • Plug out and after 7 minute plug in again. YES NO - 17 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B To confirm when compressor is operating. NO Does frost adhere to evaporator much? YES • Gap of door. • Defect of control PCB. YES • Gas leakage at high pressure side. • Poor compression. • Defect of control PCB. YES • Gas leakage at low pressure side. • Defect of control PCB. NO Does the “ECONAVI Led” turn off, “Quick Freezing” turn off and “Freezer Control” LED “MAX” blinking? NO Does the “ECONAVI Led” turn off, “Quick Freezing” turn off and “Freezer Control” LED “MIN” blinking? - 18 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 10.3 ECONAVI operation doesn’t work (PC/FC/IC cooling condition is normal) 1 Is the temperature control set to { 2 (Middle) } for FC? NO • FC set to { 2 (Middle) } YES 2 Does LED indicate “ECONAVI Led” or “Quick Freezing” or “Freezer Control” LED lighting and blinking? • Some LED indicator is displayed on the notice indicator area, ECONAVI will not operate. YES NO 3 Does “Quick Freezing” function operating? YES • The internal temperature is high, ECONAVI will not operate. YES • Quick Freezing is operating, ECONAVI will not operate. NO 4 Is the FC temperature -17°C or below? YES 5 Does “Freezer Control” LED turn on MAX blink? YES • Faulty operation panel PCB. NO 6 Press “Freezer” button 5 seconds. Unlit (ECONAVI) • Faulty control PCB. • Faulty operation panel PCB. Turn off setting 7 It is normal (keep a wait and see) If it meets the above condition, ECONAVI operation begins and the lamp lights when the door opening and closing is not done for 3 hours. (with some exceptions) Test of ECONAVI operation. (Quickly confirms for turning on the { ECONAVI } lamp) White in service mode, shield the sensing part of ECONAVI sensor from the light. Keep 1 minute without door opening and closing to turn on the { ECONAVI } lamp. Precondition : The refrigerator compartment and freezer compartment are set to { 2 (Middle) }. - 19 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 11. SCHEMATIC DIAGRAM 11.1 WIRING DIAGRAM : NR-BX418XS, NR-BX468XS / NR-BX418GW, NR-BX468GW NR-BX41BXS, NR-BX46BXS, NR-BX418GK, NR-BX468GK :,1',1*5(6,67$1&(9$/8( 8 : 8 9 : 9 - 20 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 11.2 WIRING DIAGRAM : NR-BX418VS, NR-BX418VW / NR-BX468VS, NR-BX468VW NR-BX41BVW, NR-BX46BVW :,1',1*5(6,67$1&(9$/8( 8 : 8 9 : 9 - 21 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 12. DISASSEMBLY INSTRUCTION 12.1 COVER LED LAMP / PAS-BW468(LED) D) Fig. 1 Fig. 2 1. Prepare black tape to head of screwdriver (Regular tips) as Fig.1 2. Take off cover LED lamp by use screwdriver put between gaps of cover LED lamp with PC Liner at the lock point as Fig. 2. Fig. 4 Fig. 3 3. Check the locks point by see at “Arrow Mark” 3 position as Fig. 3. 4. Use screwdriver push up PAS-BW468V (LED) soft and carefully for lock loose as Fig. 4. Fig. 5 5. Use hand pull up socket of PAS-BW468V (LED) for change new part as Fig.5. - 22 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 12.2 PAS-OPERATED CONTROL (DOOR) FOR G TYPE Fig. 1 Fi Fig. 2 Fig. 3 1. Take off cover board control at PC Door as Fig. 1. 2. Take off screw 1 pcs at PC door by use screwdriver as Fig. 2. 3. Pull out Holder boad control up as Fig. 3. Fig. 4 Fig. 5 Fig. 6 4. Take off Lead Wire Socket which contact at PAS-operated control (Door) as Fig. 4. 5. Take off screw by screwdriver at PAS-operated control (Door) as Fig. 5. 6. Use hands pull at lock for left up PAS-operated control (Door ) loose from Holder boad control as Fig. 6. - 23 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 12.3 PAS-OPERATED CONTROL (DOOR) FOR X TYPE Fig. 1 Fig. 2 1. Take off by use small screwdriver put between gaps Door control As with PC door try to push it in front slowly for locks loose and pull up as Fig. 1 2. Take off Lead Wire Socket which contact at PAS-operated control (Door) as Fig.2 Fig. 3 Fig. 4 3. Take off screw by screwdriver at PAS-operated control (Door) Fig. 3 4. Use hands pull at lock for left up PAS-operated control (Door) loose from Cover Control Fig.3 - 24 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 12.4 COVER DAMPER PC AS / FAN MOTOR. Fig. 1 Fig. 2 Fig. 3 1. Take off screw at Barrier PF As by use screwdriver 4 position as Fig.1 2. Pull out Barrier PF As slowly as Fig.2 3. Use screwdriver open at botton plate control , take off screw on cover duct PC 4 position and take off cover duct control as Fig.3 Fig. 4 Fig. 5 Fig. 6 4. Take off screw at cover damper PC As 2 position and pull out Cover damper PC slowly as Fig.4 5. Take off connector Lead wire of electric damper and PCC sensor , PFC sensor from cover duct PC As as Fig.5 6. After that take off at the cover damper and other parts as Fig.6 Rib lock Fig. 7 Fig. 8 Fig. 9 7. Take off connector of Fan motor as Fig.7 8. Take off fan motor by use hand pull at rib lock 2 position and push out fan motor as Fig.8 9. After that take off fan motor as Fig.9 - 25 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 13. SERVICE INFORMATION 13.1 Dryer set (Kit) R600a Part No : CNR600A-001 From PAPTH Dryer 1x5 gm Dryer Set For R600a Regasing Swagelock tube fitting 1x6.35mm Part No : CNRMF-102270 From Domain Japan Swagelock tube fitting 1x4.76mm Dryer branch pipe 1x3/16” Gas charge port pipe 1x1/4” Heat-shrinkble tubes 30mm x 2tubes Without Gas charge port pipe 1/4” and swagelock tube fitting 6.35mm Cable tie - 26 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 13.2 Insert the D-joint Pipe (Capilary tube into Dryer) 1) Insert the capillary tube into the position of the mesh.(Pic.1) Pic.1 2) Mark the position where the tube touched the mesh.(Pic.2) Pic.2 3) Return the capillary tube about 5mm.(Pic.3) Pic.3 4) Bend the capillary tube.(Pic.4) Pic.4 - 27 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 13.3 Notes of wire connected work (Scotch Lock) - 28 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 14. PARTS EXPLODED VIEW AND REPLACEMENT PARTS LIST 14.1 PARTS EXPLODED VIEW : BODY 5 6 7 3 1 4 2 12 11 8 Max Med Fridge Min Quick Freezing 10 Max Freezer Med Min 9 (VS,VW) 13 22 20 21 29 23 15 28 25 14 24 30 17 16 26 18 27 19 31 33 35 32 34 37 36 41 44 45 42 38 49 46 42.1 47 50 43 51 39 52 48 40 53 54 - 29 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 14.2 PARTS EXPLODED VIEW : DOOR 63 56.3 56.2 64 56.1 57 55 60 62 61 58 56 59 78 65 (GW,GK) 68 69 66 67 INVERTER ECONAVI (XS,GW,GK) 70 (XS) ECONAVI (VS,VW) (GW,GK) 71 72 73 74 77 75 76 - 30 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B 14.3 PARTS EXPLODED VIEW : PACKING STICKER BARCODE PACKING BELT TOP PAD F & B (FOR HK, X1, GW, GK TYPE ALL) FOAM TOP PAD L, R Max PAD CORNER (X1, AU-NZ, GW, GK TYPE ALL) Min Chill Quick Freezing Fridge Prime Fresh Freezer PROTECTOR DOOR AS. (HK, X1, AU-NZ, GW, GK TYPE ALL) BOTTOM TRAY AS. - 31 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B REPLACEMENT PARTS LIST Important safety notice : Components identified by mark have special characteristics important for safety. When replacing any of these components, use only manufacturer's specified part. Part List : NR-BX418, NR-BX41B SERIES Safety Ref. No. 1 Part name Part No. XS COVER HINGE TOP CNRAE-143500 COVER HINGE TOP CNRAE-143390 COVER HINGE TOP CNRAE-143490 Model/Qty NR-BX418/NR-BX41B VS VW GW Remark GK 1 COLOUR : STAINLESS 1 COLOUR : SHINNING SILVER (S) 1 1 COLOUR : KOREA WHITE SOLID COVER HINGE TOP CNRAE-143640 2 HINGE TOP CNRAE-143480 1 1 1 1 1 3 PAS-BW468(LED) CNRBG-181513 1 1 1 1 1 4 COVER LED LAMP CNRAH-290283 1 1 1 1 1 5 TRAY PC AS. CNRBH-162310 2 2 2 2 2 6 TRAY CRISPER AS. CNRBH-162320 1 1 1 1 1 7 CASE CRISPER AS. CNRBH-162251 1 1 1 1 1 8 BARRIER PF AS CNRBH-162241 1 1 BARRIER PF AS CNRBH-162231 1 1 1 9 CASE PF AS. CNRBH-162261 1 1 1 10 COVER CONTROL AS. CNRBH-162221 11 PAS-OPERATION PCB (INSIDE) ARBP01A00090 12 DOOR SW. CNRAG-153290 13 HINGE CENTER CNRAE-143230 14 CAP PAN H.4TS (N) CNR391627200 15 CAP PAN H.4TS (W) CNR391624310 15 CAP PAN H.4TS (K) CNR391613410 16 HINGE BOTTOM CNRAE-143200 1 17 CASTER L AS. CNRBC-365190 CASTER R AS. CNRBC-365200 COVER LEG R CNRAJ-171472 1 COVER LEG R CNRAJ-172373 COVER LEG R CNRAJ-172383 COVER LEG R CNRAJ-173170 COVER LEG L CNRAJ-172392 COVER LEG L CNRAJ-172403 COVER LEG L CNRAJ-172413 18 19 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 COLOUR : SHINNING SILVER (S) 1 1 COLOUR : KOREA WHITE SOLID 1 1 COLOUR : ARISTON BLACK COLOUR : STAINLESS 1 COLOUR : SHINNING SILVER (S) 1 1 COLOUR : KOREA WHITE SOLID COVER LEG L CNRAJ-173180 CNRAF-183091 1 1 1 1 1 21 SUPPORT COIL CNRAF-163503 1 1 1 1 1 22 SENSOR DEF. CNRAG-168580 1 1 1 1 1 23 COIL AS. CNRBF-164301 1 1 1 1 1 24 TEMP FUSE AS. CNRBG-202560 1 1 1 1 1 25 SENSOR FCC CNRAG-175141 1 1 1 1 1 26 COVER RADIANT CNRAG-161260 1 1 1 1 1 27 HEATER AS. DEFROST CNRAG-169652 1 1 1 1 1 28 COVER COIL AS. CNRBF-164311 1 1 1 1 1 29 CASE FCT AS CNRBH-162282 1 1 1 1 1 30 CASE FCM AS CNRBH-162292 1 1 1 1 1 31 CASE FCB AS CNRBH-162302 1 1 1 1 1 32 HOLDER ICE TRAY CNRAH-326181 1 1 1 1 1 33 ICE CUBE TRAY AS. CNRBH-135250 1 1 1 1 1 34 BOX ICE TRAY CNRAH-227460 1 1 1 1 1 35 HANGER SHELL R AS. CNRBC-299074 1 1 1 1 1 36 HANGER SHELL L AS. CNRBC-299083 1 1 1 1 1 37 WIRING DIAGRAM - XSVN CNRAH-329622 1 39 COLOUR : BLACK COLOUR : STAINLESS 1 SUPPORT COIL D 38 X,G Type V Type 1 1 WIRING DIAGRAM - XSMY CNRAH-329631 1 WIRING DIAGRAM - XSPH CNRAH-329641 1 WIRING DIAGRAM - XSHK CNRAH-329651 1 WIRING DIAGRAM - XSAU CNRAH-329662 1 WIRING DIAGRAM - VSTH CNRAH-329681 1 WIRING DIAGRAM - VSVN CNRAH-329692 1 CNRAH-329701 V Type V Type 20 WIRING DIAGRAM - VS1D COLOUR : ARISTON BLACK COLOUR : ARISTON BLACK 1 WIRING DIAGRAM - VSWA CNRAH-329611 1 WIRING DIAGRAM - VSX1 CNRAH-329711 1 WIRING DIAGRAM - VSAU CNRAH-329722 WIRING DIAGRAM - GWVN CNRAH-329731 WIRING DIAGRAM - GWMY CNRAH-329741 1 WIRING DIAGRAM - GWHK CNRAH-329751 1 1 1 WIRING DIAGRAM - GKMY CNRAH-336560 1 COLOUR : BLACK WIRING DIAGRAM - GKVN CNRAH-336570 1 COLOUR : BLACK 1 COLOUR : BLACK WIRING DIAGRAM - GK1D CNRAH-336580 LABEL HC BACK - EXPORT CNRAH-269292 LABEL HC BACK - TH CNRAH-311730 PAS-CONTROL PCB AS ARBPC1A01774 1 PAS-CONTROL PCB AS ARBPC1A02123 1 PAS-CONTROL PCB AS ARBPC1A01784 1 PAS-CONTROL PCB AS ARBPC1A02133 1 1 1 1 1 1 - 32 - 1 1 LANGUAGE : ENGLISH 1 LANGUAGE : THAI 1 FOR TH,MY,SG,PH,HK,WA,X1 1 FOR VN,AU-NZ 1 FOR VN,AU-NZ FOR TH,1D,WA,X1 NR-BX418/NR-BX468/NR-BX41B/NR-BX46B Safety Ref. No. Part name Part No. XS Model/Qty NR-BX418/NR-BX41B VS VW GW 40 COVER BOARD AS. CNRBC-377851 1 1 41 SUPPLY CORD AS. - TH CNRBG-202031 1 1 SUPPLY CORD AS. - MY,SG,HK CNRBG-201921 1 SUPPLY CORD AS. - VN CNRBG-202080 1 SUPPLY CORD AS. - 1D CNRBG-202320 SUPPLY CORD AS. - PH CNRBG-202090 SUPPLY CORD AS. - WA CNRBG-202580 SUPPLY CORD AS. - X1 CNRBG-202100 SUPPLY CORD AS.- AU,NZ CNRBG-202110 PAN WATER EVA. CNRAF-196452 42 42.1 1 1 Remark GK 1 1 1 1 1 1 FOR MY,SG,HK 1 1 FOR VN 1 FOR 1D 1 1 FOR PH 1 FOR WA 1 1 1 FOR X1 1 1 1 1 1 1 FOR AU-NZ PIPE WATER EVA. CNRAF-196481 1 1 1 1 1 43 CLAMP PIPE WATER EVA. CNRAF-175252 1 1 1 1 1 44 U-RING 7 CNRAJ-163240 4 4 4 4 4 45 COMP. ERI100E13DGH-C0ECS CNR91-236280 1 1 1 COMP. EFI100E13DGH-C0ECS CNR91-236390 46 MOTOR PROTECTOR CNR06-598071 1 1 1 47 PROTECTOR COVER CNRAG-170461 1 1 1 1 1 48 EARTH WIRE AS. COMP.150 CNRBG-168610 1 1 1 1 1 49 5 DRYER W CNR393400920 1 1 1 1 1 50 RUBBER GROMMET CNRAJ-163250 4 4 4 4 4 51 CLAMPER DRYER CNR39-350251 1 1 1 1 1 52 CROSSRAIL REAR AS. CNRBF-164321 1 1 1 1 1 53 PIN CASTER CNR02-325701 2 2 2 2 2 54 ROLLER 40 CNRAC-116280 2 2 2 2 2 55 FAN MOTOR AS. CNRAG-175341 1 1 1 1 1 56 COVER DUCT PC AS. CNRBH-162191 1 1 1 1 1 56.1 COVER DUCT PC CNRAH-326232 1 1 1 1 1 56.2 INS. DUCT PC CNRAH-326241 1 1 1 1 1 56.3 SEAL DUCT PC CNRAJ-171890 1 1 1 1 1 57 AG BIO FILTER CNRAH-278440 1 1 1 1 1 58 COVER DAMPER PC AS. CNRBH-162201 1 1 1 COVER DAMPER PC AS. CNRBH-162211 1 1 59 COVER DAMPER PC CNRAH-325981 1 1 1 1 1 60 INS DAMPER PCT CNRAH-325990 1 61 INS DAMPER PCT CNRAH-326210 INS DAMPER PCB CNRAH-326000 INS DAMPER PCB CNRAH-326220 1 1 1 1 1 1 1 1 1 1 1 1 1 CNRBG-201991 SINGLE ELECTRIC DAMPER AS. CNRBG-202001 63 SENSOR PCC CNRAG-175151 1 64 SENSOR PFC CNRAG-175161 1 65 GASKET DOOR PC CNRAD-384910 1 1 1 66 EMBLEM CNRAD-379982 1 1 1 67 DOOR AS. PC (FOAM) - XS CNRBD-401651 1 DOOR AS. PC (FOAM) - VS CNRBD-401671 DOOR AS. PC (FOAM) - VW CNRBD-401691 DOOR AS. PC (FOAM) - GW CNRBD-402151 DOOR AS. PC (FOAM) - GK CNRBD-406220 PAS-OPERATION PCB(DOOR) ARBP0DA00700 PAS-OPERATION PCB(DOOR) ARBP0DA00690 DOOR CONTROL AS.(XS) CNRBD-401821 SEAL ESCUTCHEON CNRAD-386051 SEAL ESCUTCHEON CNRAD-386061 HOLDER BOARD CONTROL AS CNRBD-402191 70 LATCH DOOR CNRAE-136513 1 1 71 STOPPER DOOR CNRAD-359750 1 72 GASKET DOOR FC CNRAD-384630 1 73 DOOR AS. FC (FOAM) - XS CNRBD-401761 1 DOOR AS. FC (FOAM) -VS CNRBD-401781 DOOR AS. FC (FOAM) -VW CNRBD-401801 68 69 DOOR AS. FC (FOAM) - GW CNRBD-401851 DOOR AS. FC (FOAM) - GK CNRBD-406010 FOR XS GW FOR VN VW 1 TWIN ELECTRIC DAMPER AS. 62 FOR TH 1 1 1 1 1 1 1 1 1 1 1 COLOUR : STAINLESS 1 COLOUR : CHAMPAGNE 1 COLOUR : WHITE 1 COLOUR : KOREA WHITE SOLID 1 1 COLOUR : BLACK FOR XS MODEL 1 1 1 FOR GW MODEL FOR XS MODEL 1 FOR VS MODEL 1 FOR VW MODEL 1 1 1 1 1 1 1 1 1 1 1 FOR GW, GK MODEL 1 COLOUR : STAINLESS 1 COLOUR : SHINNING SILVER (S) 1 COLOUR : WHITE 1 COLOUR : KOREA WHITE SOLID 1 74 SHELF EGG CNRAD-384691 1 1 1 1 1 75 TRAY EGG 10 CNRAD-338111 1 1 1 1 1 76 SHELF BOTTLE CNRAD-384680 1 1 1 1 1 77 LABEL NAME & REF. (PRINT)-XSVN CNRAH-328611 1 LABEL NAME & REF. (PRINT)-XSMY CNRAH-328620 1 LABEL NAME & REF. (PRINT)-XSPH CNRAH-328630 1 LABEL NAME & REF. (PRINT)-XSHK CNRAH-328641 1 LABEL NAME & REF. (PRINT)-XSAU CNRAH-328650 1 LABEL NAME & REF. (PRINT)-VSTH CNRAH-328670 1 LABEL NAME & REF. (PRINT)-VSVN CNRAH-328680 1 LABEL NAME & REF. (PRINT)-VS1D CNRAH-328690 1 LABEL NAME & REF. (PRINT)-VSWA CNRAH-328700 1 LABEL NAME & REF. (PRINT)-VSX1 CNRAH-328710 1 LABEL NAME & REF. (PRINT)-VWAU CNRAH-328720 LABEL NAME & REF. (PRINT)-GWVN CNRAH-328731 LABEL NAME & REF. (PRINT)-GWMY CNRAH-328740 1 LABEL NAME & REF. (PRINT)-GWHK CNRAH-328751 1 COLOUR : BLACK 1 1 LABEL NAME & REF. (PRINT)-GKMY CNRAH-336490 1 COLOUR : BLACK LABEL NAME & REF. (PRINT)-GKVN CNRAH-336500 1 COLOUR : BLACK LABEL NAME & REF. (PRINT)-GK1D CNRAH-336510 1 COLOUR : BLACK - 33 - NR-BX418/NR-BX468/NR-BX41B/NR-BX46B Packing List Safety Ref. No. Part name Part No. XS Model/Qty NR-BX418/NR-BX41B VS VW GW Remark GK 78 COVER BOARD CONTROL CNRAD-384822 1 1 FOR GW 78 COVER BOARD CONTROL CNRAD-329140 1 1 FOR GK PACKING AS. - VN CNRBK-140541 PACKING AS. - MY CNRBK-141541 1 PACKING AS. - PH CNRBK-141551 1 PACKING AS. - HK CNRBK-141561 1 PACKING AS. - AU CNRBK-141571 1 PACKING AS.-TH CNRBK-140561 1 PACKING AS.-VN CNRBK-141591 1 PACKING AS.-1D CNRBK-141601 1 PACKING AS.-WA CNRBK-141611 1 PACKING AS.-X1 CNRBK-141621 1 PACKING AS.-AU CNRBK-140581 PACKING AS.-VN CNRBK-141631 PACKING AS.-MY CNRBK-141641 1 PACKING AS.-HK CNRBK-141651 1 1 1 1 PACKING AS.-GKMY CNRBK-144050 1 PACKING AS.-GKVN CNRBK-144060 1 PACKING AS.-GK1D CNRBK-144070 BOTTOM TRAY AS. CNRBK-140591 BOTTOM TRAY AS. CNRBK-142150 PLASTIC COVER 1 1 1 1 1 1 CNRAJ-157260 1 1 1 1 1 TOP PAD F CNRAK-156160 1 1 1 1 1 FOR X1 , AU-NZ , GW,GK TYPE ALL TOP PAD B CNRAK-156170 1 1 1 1 1 FOR X1 , AU-NZ , GW,GK TYPE ALL TOP PAD L CNRAK-174090 1 1 1 1 1 TOP PAD R CNRAK-174100 1 1 1 1 1 PROTECTOR DOOR AS. CNRBK-117320 1 1 1 1 1 FOR HK , X1 ,AU-NZ ,GW ,GK TYPE ALL PAD CORNER CNRAK-174210 1 1 1 1 1 FOR X1 , AU-NZ , GW ,GK TYPE ALL DOOR PC PAD CNRAK-141050 1 1 1 1 1 INSTRUCTION BOOK - VN CNRAK-174260 1 1 1 1 INSTRUCTION BOOK - MY CNRAK-174220 1 1 1 INSTRUCTION BOOK - PH CNRAK-174700 1 INSTRUCTION BOOK - HK CNRAK-174270 1 INSTRUCTION BOOK - AU,NZ CNRAK-174280 INSTRUCTION BOOK - X1 CNRAK-174290 INSTRUCTION BOOK - TH CNRAK-174150 1 INSTRUCTION BOOK - 1D CNRAK-174240 1 INSTRUCTION BOOK - WA,AE,WG CNRAK-174250 1 1 1 1 - 34 - 1 1 1 1 NR-BX418/NR-BX468/NR-BX41B/NR-BX46B REPLACEMENT PARTS LIST Important safety notice : Components identified by mark have special characteristics important for safety. When replacing any of these components, use only manufacturer's specified part. Parts List : NR-BX468, NR-BX46B SERIES Safety Ref. No. Part name Part No. XS Model/Qty NR-BX468/NR-BX46B VS VW GW Remark GK COVER HINGE TOP-ST CNRAE-143500 COVER HINGE TOP-GY CNRAE-143390 COVER HINGE TOP-GW CNRAE-143490 COVER HINGE TOP CNRAE-143640 2 HINGE TOP CNRAE-139023 1 1 1 1 1 3 PAS-BW468(LED) CNRBG-181513 1 1 1 1 1 4 COVER LED LAMP CNRAH-290283 1 1 1 1 1 5 TRAY PC AS. CNRBH-162310 1 1 1 1 1 6 TRAY CRISPER AS. CNRBH-162320 1 1 1 1 1 7 CASE CRISPER AS. CNRBH-162251 1 1 1 1 1 8 BARRIER PF AS CNRBH-162231 1 1 1 1 1 1 1 BARRIER PF AS 1 COLOUR : STAINLESS 1 COLOUR : SHINNING SILVER (S) 1 1 COLOUR : KOREA WHITE SOLID 1 CNRBH-162241 1 1 9 CASE PF AS. CNRBH-162261 10 COVER CONTROL AS. CNRBH-162221 11 PAS-OPERATION PCB (INSIDE) ARBP01A00090 12 DOOR SW. CNRAG-153290 1 1 1 1 13 HINGE CENTER CNRAE-143230 1 1 1 1 14 CAP PAN H.4TS (N) CNR391627200 1 1 15 CAP PAN H.4TS (W) CNR391624310 1 1 15 CAP PAN H.4TS (K) CNR391613410 16 HINGE BOTTOM CNRAE-143470 1 1 1 1 1 17 CASTER L AS. CNRBC-365190 1 1 1 1 1 CASTER R AS. CNRBC-365200 1 1 1 1 1 COVER LEG R CNRAJ-171472 1 COVER LEG R CNRAJ-172373 COVER LEG R CNRAJ-172383 18 1 1 1 1 1 1 1 1 COLOUR : SHINNING SILVER (S) 1 1 COLOUR : KOREA WHITE SOLID COVER LEG R CNRAJ-173170 CNRAJ-172392 COVER LEG L CNRAJ-172403 COVER LEG L CNRAJ-172413 COVER LEG L CNRAJ-173180 20 SUPPORT COIL D CNRAF-183091 1 1 1 1 1 21 SUPPORT COIL CNRAF-163503 1 1 1 1 1 22 SENSOR DEF. CNRAG-168580 1 1 1 1 1 23 COIL AS. CNRBF-164301 1 1 1 1 1 24 TEMP FUSE AS. CNRBG-202560 1 1 1 1 1 25 SENSOR FCC CNRAG-175141 1 1 1 1 1 26 COVER RADIANT CNRAG-161260 1 1 1 1 1 27 HEATER AS. DEFROST CNRAG-169652 1 1 1 1 1 28 COVER COIL AS. CNRBF-164311 1 1 1 1 1 29 CASE FCT AS CNRBH-162282 1 1 1 1 1 30 CASE FCM AS CNRBH-162292 1 1 1 1 1 31 CASE FCB AS CNRBH-162302 1 1 1 1 1 32 HOLDER ICE TRAY CNRAH-326181 1 1 1 1 1 33 ICE CUBE TRAY AS. CNRBH-135250 1 1 1 1 1 34 BOX ICE TRAY CNRAH-227460 1 1 1 1 1 35 HANGER SHELL R AS. CNRBC-299074 1 1 1 1 1 36 HANGER SHELL L AS. CNRBC-299083 1 1 1 1 1 37 WIRING DIAGRAM - XSTH CNRAH-327161 1 WIRING DIAGRAM - XSVN CNRAH-327872 1 WIRING DIAGRAM - XSMY CNRAH-327921 1 WIRING DIAGRAM - XSSG CNRAH-327931 1 WIRING DIAGRAM - XSS1 CNRAH-339820 1 WIRING DIAGRAM - XSPH CNRAH-327981 1 WIRING DIAGRAM - XSHK CNRAH-327941 1 WIRING DIAGRAM - XSWA CNRAH-327881 1 WIRING DIAGRAM - XSAU CNRAH-327992 1 WIRING DIAGRAM - VSTH COLOUR : ARISTON BLACK COLOUR : STAINLESS 1 COLOUR : SHINNING SILVER (S) 1 1 COLOUR : KOREA WHITE SOLID 1 COLOUR : ARISTON BLACK FOR S1 1 WIRING DIAGRAM - VSVN CNRAH-327892 1 WIRING DIAGRAM - VS1D CNRAH-327901 1 WIRING DIAGRAM - VSX1 CNRAH-328021 1 WIRING DIAGRAM - VWAU CNRAH-328002 WIRING DIAGRAM - GWTH CNRAH-327861 1 WIRING DIAGRAM - GWVN CNRAH-327912 1 WIRING DIAGRAM - GWMY CNRAH-327951 1 WIRING DIAGRAM - GWSG CNRAH-327961 1 WIRING DIAGRAM - GWSG CNRAH-339810 1 WIRING DIAGRAM - GWHK CNRAH-327971 1 WIRING DIAGRAM - GKTH CNRAH-335890 WIRING DIAGRAM - GKMY CNRAH-336520 1 WIRING DIAGRAM - GKVN CNRAH-336530 1 WIRING DIAGRAM - GK1D 38 1 1 CNRAH-327851 COLOUR : BLACK COLOUR : STAINLESS 1 COVER LEG L 19 COLOUR : ARISTON BLACK 1 FOR S1 1 CNRAH-336540 1 WIRING DIAGRAM - GKS1 CNRAH-339800 LABEL HC BACK - EXPORT CNRAH-269292 1 1 LABEL HC BACK - TH CNRAH-311730 1 1 1 - 35 - 1 FOR S1 1 LANGUAGE : ENGLISH 1 LANGUAGE : THAI NR-BX418/NR-BX468/NR-BX41B/NR-BX46B Safety Ref. No. 39 Part name Part No. XS PAS-CONTROL PCB AS ARBPC1A01774 1 PAS-CONTROL PCB AS ARBPC1A02123 1 PAS-CONTROL PCB AS ARBPC1A01784 Model/Qty NR-BX468/NR-BX46B VS VW GW Remark GK 1 FOR TH,MY,SG,PH,HK,WA,X1 FOR VN,AU-NZ 1 1 FOR TH,MY,SG,PH,HK,WA,X1 PAS-CONTROL PCB AS ARBPC1A02133 40 COVER BOARD AS. CNRBC-377851 1 1 1 1 1 1 1 41 SUPPLY CORD AS. - TH CNRBG-202031 1 SUPPLY CORD AS. - MY,SG,HK CNRBG-201921 1 1 1 1 1 1 1 SUPPLY CORD AS. - VN CNRBG-202080 1 FOR MY,SG,HK 1 1 1 FOR VN,WA SUPPLY CORD AS. - 1D CNRBG-202320 SUPPLY CORD AS. - PH CNRBG-202090 1 SUPPLY CORD AS. - X1 CNRBG-202100 1 SUPPLY CORD AS.- AU,NZ CNRAG-175420 1 42 PAN WATER EVA. CNRAF-196452 1 1 1 1 1 42.1 PIPE WATER EVA. CNRAF-196481 1 1 1 1 1 43 CLAMP PIPE WATER EVA. CNRAF-175252 1 1 1 1 1 44 U-RING 7 CNRAJ-163240 4 4 4 4 1 45 COMP. ERI100E13DGH-C0ECS CNR91-236280 1 1 1 COMP. EFI100E13DGH-C0ECS CNR91-236390 46 MOTOR PROTECTOR CNR06-598071 47 PROTECTOR COVER 48 EARTH WIRE AS. COMP.150 49 5 DRYER W 50 1 FOR VN,AU-NZ 1 1 FOR X1 1 FOR AU-NZ 1 1 1 1 1 1 CNRAG-170461 1 1 1 1 1 CNRBG-168610 1 1 1 1 1 CNR393400920 1 1 1 1 1 RUBBER GROMMET CNRAJ-163250 4 4 4 4 4 51 CLAMPER DRYER CNR39-350251 1 1 1 1 1 52 CROSSRAIL REAR AS. CNRBF-164321 1 1 1 1 1 53 PIN CASTER CNR02-325701 2 2 2 2 2 54 ROLLER 40 CNRAC-116280 2 2 2 2 2 55 FAN MOTOR AS. CNRAG-175341 1 1 1 1 1 56 COVER DUCT PC AS. CNRBH-162181 1 1 1 1 1 56.1 COVER DUCT PC CNRAH-325952 1 1 1 1 1 56.2 INS. DUCT PC CNRAH-325961 1 1 1 1 1 56.3 SEAL DUCT PC CNRAJ-171500 1 1 1 1 1 57 AG BIO FILTER CNRAH-278440 1 1 1 1 1 58 COVER DAMPER PC AS. CNRBH-162201 1 1 1 COVER DAMPER PC AS. CNRBH-162211 59 COVER DAMPER PC CNRAH-325981 1 60 INS DAMPER PCT CNRAH-325990 1 INS DAMPER PCT CNRAH-326210 INS DAMPER PCB CNRAH-326000 INS DAMPER PCB CNRAH-326220 1 1 1 1 1 1 1 1 1 1 1 1 1 62 TWIN ELECTRIC DAMPER AS. SINGLE ELECTRIC DAMPER AS. CNRBG-202001 63 SENSOR PCC CNRAG-175151 1 64 SENSOR PFC CNRAG-175161 1 65 GASKET DOOR PC CNRAD-384590 1 1 1 66 EMBLEM CNRAD-379982 1 1 1 67 DOOR AS. PC (FOAM) - XS CNRBD-401641 1 DOOR AS. PC (FOAM) - VS CNRBD-401661 DOOR AS. PC (FOAM) - VW CNRBD-401681 DOOR AS. PC (FOAM) - GW CNRBD-401871 DOOR AS. PC (FOAM) - GK CNRBD-405990 PAS-OPERATION PCB(DOOR) ARBP0DA00700 PAS-OPERATION PCB(DOOR) ARBP0DA00690 68 69 CNRBG-201991 DOOR CONTROL AS.(XS) CNRBD-401822 SEAL ESCUTCHEON CNRAD-386051 SEAL ESCUTCHEON CNRAD-386061 FOR 1D FOR PH 1 1 61 FOR TH 1 FOR XS GW GK FOR VS VW 1 1 1 1 1 1 1 1 1 1 1 1 1 1 COLOUR : STAINLESS 1 COLOUR : CHAMPAGNE 1 COLOUR : WHITE COLOUR : KOREA WHITE SOLID 1 1 1 COLOUR : BLACK FOR XS MODEL 1 FOR GW MODEL 1 FOR XS MODEL 1 FOR VS MODEL 1 FOR VW MODEL HOLDER BOARD CONTROL AS CNRBD-402191 70 LATCH DOOR CNRAE-136513 1 1 1 1 1 71 STOPPER DOOR CNRAD-359750 1 1 1 1 72 GASKET DOOR FC CNRAD-384630 1 1 1 1 73 DOOR AS. FC (FOAM) - XS CNRBD-401761 1 DOOR AS. FC (FOAM) -VS CNRBD-401781 DOOR AS. FC (FOAM) -VW CNRBD-401801 FOR GW MODEL COLOUR : STAINLESS COLOUR : SHINNING SILVER (S) 1 1 COLOUR : WHITE COLOUR : KOREA WHITE SOLID DOOR AS. FC (FOAM) - GW CNRBD-401851 DOOR AS. FC (FOAM) - GK CNRBD-406010 1 74 SHELF EGG CNRAD-384691 1 1 1 1 1 75 TRAY EGG 10 CNRAD-338111 1 1 1 1 1 76 SHELF BOTTLE CNRAD-384680 1 1 1 1 1 77 LABEL NAME & REF. (PRINT)-XSTH CNRAH-327150 1 LABEL NAME & REF. (PRINT)-XSVN CNRAH-327591 1 LABEL NAME & REF. (PRINT)-XSMY CNRAH-327601 1 LABEL NAME & REF. (PRINT)-XSSG CNRAH-327611 1 FOR SG LABEL NAME & REF. (PRINT)-XSS1 CNRAH-339790 1 FOR S1 LABEL NAME & REF. (PRINT)-XSPH CNRAH-327620 1 LABEL NAME & REF. (PRINT)-XSHK CNRAH-327631 1 LABEL NAME & REF. (PRINT)-XSWA CNRAH-327640 1 LABEL NAME & REF. (PRINT)-XSAU CNRAH-327650 1 LABEL NAME & REF. (PRINT)-VSTH CNRAH-327670 1 LABEL NAME & REF. (PRINT)-VSVN CNRAH-327681 1 LABEL NAME & REF. (PRINT)-VS1D CNRAH-327690 1 LABEL NAME & REF. (PRINT)-VSX1 CNRAH-327700 1 LABEL NAME & REF. (PRINT)-VWAU CNRAH-327710 LABEL NAME & REF. (PRINT)-GWTH CNRAH-327720 1 1 1 - 36 - COLOUR : BLACK NR-BX418/NR-BX468/NR-BX41B/NR-BX46B Packing List Safety Ref. No. 78 Part name Part No. XS Model/Qty NR-BX468/NR-BX46B VS VW GW Remark GK LABEL NAME & REF. (PRINT)-GWVN CNRAH-327731 1 LABEL NAME & REF. (PRINT)-GWMY CNRAH-327741 1 LABEL NAME & REF. (PRINT)-GWSG CNRAH-327751 1 FOR SG LABEL NAME & REF. (PRINT)-GWS1 CNRAH-339780 1 FOR S1 LABEL NAME & REF. (PRINT)-GWHK CNRAH-327761 1 LABEL NAME & REF. (PRINT)-GKTH CNRAH-335880 1 LABEL NAME & REF. (PRINT)-GKMY CNRAH-336450 1 LABEL NAME & REF. (PRINT)-GKVN CNRAH-336460 1 LABEL NAME & REF. (PRINT)-GK1D CNRAH-336470 1 LABEL NAME & REF. (PRINT)-GKS1 CNRAH-339770 COVER BOARD CONTROL CNRAD-384822 COVER BOARD CONTROL CNRAD-329140 PACKING AS. - TH CNRBK-140531 1 PACKING AS. - VN CNRBK-141081 1 PACKING AS. - MY CNRBK-141091 1 PACKING AS. - SG CNRBK-141221 1 FOR SG PACKING AS. - S1 CNRBK-145140 1 FOR S1 PACKING AS. - PH CNRBK-141111 1 PACKING AS. - HK CNRBK-141121 1 PACKING AS. - VW CNRBK-141131 1 PACKING AS. - AU CNRBK-141141 1 1 FOR S1 1 1 FOR GW 1 1 FOR GK PACKING AS.-TH CNRBK-140551 1 PACKING AS.-VN CNRBK-141161 1 PACKING AS.-1D CNRBK-141171 1 PACKING AS.-X1 CNRBK-141181 1 PACKING AS.-AU CNRBK-141191 PACKING AS.- TH CNRBK-140571 1 PACKING AS.- VN CNRBK-141201 1 PACKING AS.- MY CNRBK-141211 1 PACKING AS.- SG CNRBK-141221 1 FOR SG PACKING AS.- S1 CNRBK-145140 1 FOR S1 PACKING AS.- HK CNRBK-141231 1 PACKING AS.- GKTH CNRBK-143770 PACKING AS.- GKMY CNRBK-144010 1 PACKING AS.- GKVN CNRBK-144020 1 PACKING AS.- GK1D CNRBK-144030 1 PACKING AS.- GKS1 CNRBK-145130 BOTTOM TRAY AS. CNRBK-140591 BOTTOM TRAY AS. CNRBK-142150 PLASTIC COVER CNRAJ-157260 1 1 1 1 1 1 1 1 1 FOR S1 1 1 TOP PAD F CNRAK-156160 1 1 1 1 FOR X1, AU-NZ, GW, GK TYPE ALL TOP PAD B CNRAK-156170 1 1 1 1 FOR X1, AU-NZ, GW, GK TYPE ALL TOP PAD L CNRAK-174090 1 1 1 1 TOP PAD R PROTECTOR DOOR As. CNRAK-174100 1 1 1 1 CNRBK-117320 1 1 1 1 FOR HK , X1 , AU-NZ, GW, GK TYPE ALL PAD CORNER CNRAK-174210 1 1 1 1 FOR X1 , AU-NZ , GW, GK TYPE ALL DOOR PC PAD CNRAK-141050 1 1 1 1 INSTRUCTION BOOK - TH CNRAK-174150 1 INSTRUCTION BOOK - VN CNRAK-174260 1 1 1 INSTRUCTION BOOK - MY CNRAK-174220 1 1 1 1 INSTRUCTION BOOK - SG,PH CNRAK-174230 1 1 1 INSTRUCTION BOOK - WA,AE,WG CNRAK-174250 1 INSTRUCTION BOOK - HK CNRAK-174270 1 INSTRUCTION BOOK - AU,NZ CNRAK-174280 1 INSTRUCTION BOOK - X1 CNRAK-174290 1 INSTRUCTION BOOK - 1D CNRAK-174240 INSTRUCTION BOOK - S1 CNRAK-177020 1 1 1 1 1 1 1 1 1 1 FOR S1 DETAIL CHANGE NOTICE Revision Item no. Page Detail Remark Jun.2016 1 1 Addition colour : GK(Black) TH,MY.SG,VN,1D 2 1 Addition model : NR-BX41B, NR-BX46B AU,NZ 3 2 Addition : Detail change notice. New page at P.37 4 26~28 5 35,36,37 Addition : Service information Addition : S1 Code For SG - 37 - ">
Advertisement
Key features
- ECONAVI intelligent cooling technology saves energy
- Multiple temperature control modes for customized cooling
- Quick freezing function for rapid freezing
- Spacious interior with adjustable shelves and compartments
- Sleek design and elegant finish