User’s manual Fig. / Abb. 1 2 / 12 – User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D This document is an English translation of the original French version. Reference J12820 version V4 and drawing number NO40FR050D User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D - 3 / 12 4 / 12 – User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D ASSOCIATED DOCUMENTATION This document must be used in association with the following documents: Document title References Consulting electronic user instructions Implant Center 2 user’s manual Piezotome 2 user’s manual Piezotome Solo user’s manual J00007 I27200 I57420 I57500 ELECTRONIC DOCUMENTATION The user instructions for your device are available in electronic format on the specified website and not in printed format. If the website is unavailable, try again later. You can also request a free printed copy of the user instructions within seven days via our website, by telephone or in writing. The electronic user instructions are available in PDF format (Portable Document Format). You will need to have a PDF file reader installed to read the electronic user instructions. It is important for you to have read and understood thecontent of the user instructions relating to the use of your device and its accessories. Never use your device without first reading the user instructions. The device user instructions can be consulted at the following addresses: www.satelec.com/documents When you receive your device, you are asked to print and/or to download all documents or sections of documents that you may need to refer to in the event of an emergency, if you are unable to connect to the internet or if your electronic display tool is not working (computer, tablet, etc.). We recommend that you visit the website regularly to consult and to download the latest version of your device's user instructions. Users are asked to keep documentation close at hand for reference when necessary. User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D - 5 / 12 The PIEZOTOME LED handpiece is equipped with a piezoelectric transducer. It has a light function for optimal lighting of the procedure site. This light function is achieved by a LED ring consisting of high-performance LEDs, giving a considerably longer life than conventional optical fiber or bulb technologies. In addition to the performance of its piezoelectric transducer and its optical properties, the front part of the PIEZOTOME LED handpiece can be completely disassembled for optimal cleaning and sterilizing. I - INSTALLATION 1. 1 PIEZOTOME LED HANDPIECE-CORD ASSEMBLY CONNECTION (Please refer to PIEZOTOME unit user's manual) - Align the mark on the cord connector with the mark on the left-hand or right-hand socket of the unit. - Insert the connector in the socket until you hear the "click". 1. 2 TIPS MOUNTING The PIEZOTOME LED handpiece is a high technology instrument requiring precautions for its use. The tips must be screwed and moderately tightened (¼ turn) by means of the PIEZOTOME specific wrench or the universal wrench of Satelec (Fig. 1). CAUTION: Correct tip vibration requires perfect tightening without overtorquing beyond the thrust point. Remove the tip after each procedure to avoid self-jamming. 6 / 12 – User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D II - MAINTENANCE Precaution: rinse the water circuit of the PIEZOTOME LED handpiece-insert assembly under running water for 20 to 30 seconds after each use. Caution: do not connect the PIEZOTOME LED handpiece- cord assembly from the unit when the instrument is powered and the control pedal is activated. 2. 1 MAINTENANCE OF THE PIEZOTOME LED HANDPIECE-CORD ASSEMBLY (Fig. 2) a) Pre-disinfection/cleaning of t h e P I E Z O T O M E LED handpiece-cord assembly The PIEZOTOME LED handpiece-cord assembly must not be cleaned in an ultrasonic bath. Disconnect the PIEZOTOME LED handpiece-cord assembly from the unit and remove the insert. Remove the tip at the front of the PIEZOTOME handpiece (Fig. 2-A). The front part of the PIEZOTOME LED handpiece can be unscrewed, for easier access to the threading and efficient and easy cleaning, using a cotton swab soaked with alcohol. Remove the optical guide from inside the PIEZOTOME LED handpiece nose (Fig. 2-A). Disconnect the l ig ht r in g fr om the PIEZOTOME LED handpiece, pulling it gently (Fig. 2-A). Clean and disinfect the body and cord, using cleaning / disinfecting towelettes with alcohol, amphoteric and biguanide base (SEPTOL™ type towelette) ready for use (refer to the manufacturer's instructions), for at least two minutes, paying particular attention to the screw thread cavity; the nose; and the optical guide and LED ring. Allow the product to act for at least 15 minutes. Use towelettes that bear the EC marking, or that are in compliance with any standard required under the applicable national regulations. b) Pre-disinfection / cleaning of the tip Pre-disinfection / chemical cleaning To be carried out immediately after treatment, wearing gloves. Immerse the tip in an ultrasonic bath (enzymatic, quaternary ammonium base detergent / disinfectant solution), carefully respecting the concentration and contact time prescribed by the manufacturer of the solution. Use a solution that bears the EC marking or that is in compliance with any standard required under the applicable national regulations. Rinse under running water for at least 30 seconds. Mechanical / chemical cleaning To be carried out immediately after pre- disinfection/chemical cleaning, wearing gloves. Scrub the tip in a new bath containing the same enzymatic, quaternary ammonium base detergent / disinfectant solution, using a metallic brush, for at least 30 seconds, and in any case until all remaining traces of contamination have been removed. Rinse again under running water for at least 30 seconds. User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D - 7 / 12 c) Drying Dry with a clean, non-woven single-use cloth, so as to remove any traces of liquid. d) Sterilization conditions Place in single-use sterilization pouches or bags in compliance with the specifications defined in standard EN ISO 11607-1, or in any equivalent standard required by the national regulations. It is essential to sterilize the handpiece, with the tip removed. e) Sterilisation The PIEZOTOME LED handpiece body and its three elements must be sterilized individually in an autoclave (Fig. 2-B) under the following conditions: - Autoclave: Type B compliant with standard EN 13060. - Sterilization temperature: 134°C. - Sterilization stabilization time: 18 minutes. - Pressure: 2 Bars min. Remove the PIEZOTOME LED handpiece-cord assembly from the autoclave as soon as sterilization is complete. Caution: • Always sterilize the PIEZOTOME LED handpiece-cord assembly without the insert. • After multiple use, and during successive sterilizations, make sure before use that the PIEZOTOME LED handpiece-cord assembly has not been damaged on the outside. f) Assembly - Connect the LED ring to the PIEZOTOME LED handpiece, making sure it is positioned correctly (align the "+" marks on the LED ring and on the handpiece body near the LED ring electrical contacts) (Fig. 3) - Insert t h e optical guide into the PIEZOTOME LED handpiece nose. - Screw on the front part (nose) of the handpiece. g) Disposal and recycling Disposal of the device and its accessories should be via a collection centre for electronic apparatus or by returning them to Satelec After Sales Service. In no circumstances should the device and its accessories be disposed of by the user. The use of the WEEE symbol indicates that this product must not be treated as household waste, but must be treated separately, in conformity to the Directive 2002/96/CE. By ensuring this product is disposed of correctly, you will help to protect the environment. For more detailed information about the recycling of this product, please contact your local authority, your house waste disposal service provider or where you purchased the product. At the end of their life, tips should be discarded in safety containers designed for this purpose 2. 2 REPLACEMENT The PIEZOTOME LED handpiece must be replaced when the thread no longer holds the tips adequately and when repeated sterilization cycles lead to visible damage of the casing (cracks, scratches). The optical guide and the light ring of the PIEZOTOME LED handpiece must be replaced when the light intensity is no longer sufficient and when repeated sterilization cycles lead to visible damage (cracks, scratches). 8 / 12 – User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D 2. 3 TROUBLESHOOTING Refer to the table FAULT No spray No water at tip but vibration present Insufficient power Low vibration POSSIBLE CAUSE REMEDY Incorrect irrigation line connection Check the irrigation line connection Obstructed tip Remove obstruction Incorrect spray adjustment Adjust spray Worn or deformed tip Replace tip Incorrect tip tightening Tighten with wrench Defective connector contacts of the No ultrasonic output PIEZOTOME LED handpiece-cord assembly Clean cord connector and socket unit contacts Cut wire in handpiece cord Return to customer service for PIEZOTOME LED handpiececord assembly replacement LED ring not fitted to the handpiece Fit the LED ring Faulty LED ring Replace the LED ring Faulty LED ring connector contacts Clean the LED ring connector contacts LED ring poles reversed Position the LED ring according to the "+" foolproofing marks. No light Faulty handpiece and/or cord connector Clean the handpiece and/or cord connector contacts contacts Other Return to SATELEC after-sales III - LIABILITY The manufacturer's liability shall not be pledged in the following cases: - Maintenance or repair by persons not authorized by the manufacturer. - Use on an electrical installation that does not comply with the regulations in force. - Other uses as those specified in this manual. The manufacturer reserves the right to modify the handpiece and/or the user's manual without prior notice. User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D - 9 / 12 MANUFACTURER IDENTIFICATION SATELEC A Company of ACTEON Group 17, avenue Gustave Eiffel BP 30216 33708 MERIGNAC cedex France Tel. +33 (0) 556.34.06.07 Fax. +33 (0) 556.34.92.92 E.mail : sa[email protected] www.acteongroup.com BRANCH ADDRESSES AUSTRALIA/NEW ZEALAND ACTEON AUTRALIA/NEW ZEALAND Suite 119, 30-40 Harcourt Parade Rosebery NSW 2018 Australia Tel. +612 9669 2292 Fax. +612 9669 2204 [email protected] MIDDLE EAST ACTEON MIDDLE EAST 247 Wasfi Al Tal str. 401 AMMAN - JORDAN Tel. +962 6 553 4401 Fax. +962 6 553 7833 [email protected] BRAZIL MICRO IMAGEM INDUSTRIA COMERCIO IMPORTAÇÃO E EXPORTAÇÃO LTDA CNPJ: 14.041.012/0001-79 Alameda Vênus, 233 Distrito Industrial Indaiatuba – SP – CEP 13347-659 Brasil Tel. +55 19 3936 809 RUSSIA ACTEON RUSSIA Moscow, Gilyarovskogo str, 6b1 +7 495 1501323 [email protected] CHINA ACTEON CHINA Office 401 - 12 Xinyuanxili Zhong Street Chaoyang District - BEIJING 100027 - CHINA Tel. +86 10 646 570 11 / 2 / 3 Fax. +86 10 646 580 15 [email protected] SPAIN ACTEON MEDICO-DENTAL IBERICA, S.A.U. Avda Principal n°11 H Poligono Industrial Can Clapers 08181 SENTMENAT (BARCELONA) - SPAIN Tel. +34 93 715 45 20 Fax. +34 93 715 32 29 [email protected] GERMANY ACTEON GERMANY GmbH Industriestrasse 9 – 40822 METTMANN GERMANY Tel. +49 21 04 95 65 10 Fax. +49 21 04 95 65 11 [email protected] TAIWAN ACTEON TAIWAN 11F., No.1, Songzhi Rd. Xinyi Dist., Taipei City 11047 TAIWAN (R.O.C.) + 886 2 8729 2103 [email protected] 10 / 12 – User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D Hong Kong Re. Office 21/F, On Hing Building Central - Hong Kong Tel. +852 66 962 134 [email protected] THAILAND ACTEON (THAILAND) LTD 23/45 Sorachai Building 16th floor - Sukumvit 63 Road, Klongton Nua - Wattana, BANGKOK 10110 - THAILAND Tel. +66 2 714 3295 Fax. +66 2 714 3296 [email protected] INDIA ACTEON INDIA 1202, PLOT NO. D-9 GOPAL HEIGHTS, NETAJI SUBASH PLACE PITAMPURA, DELHI - 110034 - INDIA Tel. +91 11 47 018 291 / 47 058 291 / 45 618 291 Fax. +91 79 2328 7480 [email protected] U.K. ACTEON UK Phoenix Park– Eaton Socon, St Neots CAMBS PE19 8EP - UK Tel. +44 1480 477 307 Fax. +44 1480 477 381 [email protected] LATIN AMERICA ACTEON LATINA AMERICA Bogotà - COLOMBIA Celular: +57 312 377 8209 [email protected] U.S.A. & Canada ACTEON North America 124 Gaither Drive, Suite 140 Mount Laurel, NJ 08054 - USA Tel. +1 856 222 9988 Fax. +1 856 222 4726 [email protected] User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D - 11 / 12 User’s manual | Piezotome 2 Handpiece | J12821 | V4 |09 | 04/2018 | NO40EN050D
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement