MICRO-EPSILON optoNCDT 1700, 1700BL User manual

MICRO-EPSILON optoNCDT 1700, 1700BL User manual
Proper Environment
-- Protection class: Membrane Keys, LED‘s
IP 65 (only with sensor cable connected)
Measurement mode (normal operation):
-- zero key:
ƒƒ Sets the analog output to the value for the midrange, i.e. 5 VDC or
12 mA.
ƒƒ Pressing the zero key again resets the function.
-- function key:
ƒƒ Switches the sensor to setup mode.
Lenses are excluded from protection class. Contamination of the lenses leads to impairment or
failure of the function.
-- Operating temperature: 0 ... 50 °C (+32 up to +122 °F)
-- Storage temperature:
-20 ... 70 °C (-4 up to +158 °F)
-- Humidity: 5 - 95 % (no condensation)
-- Ambient pressure:
Atmospheric pressure
The sensors of the series
optoNCDT 1700 are optical sensors with which is
measured in the μm area.
Make sure that
mounting and operation is handled
carefully!
18.5
(.73)
80 (3.15)
5 (.20) 70 (2.76)
15
Mount the sensors
with three screws
type M4. The
bearing surfaces
surrounding the
fastening holes
(through holes) are
slightly raised.
Mounting holes
3 x ø 0.5 mm (.18 dia)
40 (1.57)
ø 5 (.20 dia.)
(.59)
130 (5.12)
140 (5.51)
150 (5.91)
Setup mode (function key actuated):
-- function key:
ƒƒ For running through the levels and parameters.
-- select key:
ƒƒ To open the selection list and
ƒƒ select the value of the parameter in sequence.
-- enter key:
ƒƒ For saving the selected parameter value and
ƒƒ returning to measurement mode. ­
i
75 (2.95)
101(3.98)
85 (3.35)
Pressing and holding the function/enter key for longer than 5 seconds, overwrites all the parameter values with the factory settings (default
values).
Sensor Mounting
17.5
(.69)
35 (1.38)
Dimensional Drawing and Free Space,
Measuring Ranges 40/500/750 mm
Measuring Ranges 500/750BL
17.5
(.69)
If approximately 15 seconds have elapsed since the last press of the function key or
30 seconds since the last press of the select key, the sensor returns to measurement mode
without changing the parameters.
LED
Status
Measurement mode
illuminated
Object is in the measurement
range or error
off
12 (.47)
state
35 (1.38)

SMR
Inputs and Outputs

flashes quickly
...
Selected parameter value does not
match the saved value
off
Indication of the parameter values
Selected parameter value
level 1
flashing red
flashing
MR
Dimensions in mm
(inches), not to scale
MR = Measuring range
SMR = Start of measuring range
MMR = Midrange
EMR = End of measuring range
MR
SMR
a
e
40
175
22.1 °
21.8 °
500
200
19.3 °
7.0 °
750
200
19.3 °
5.0 °
+U B
14
9
10
8
7
Power supply (11 ... 30 VDC)
System ground for power supply and
GND
switching signals (Laser on/off, Zero,
Limits)
Current 4 ... 20 mA or
Analog output
voltage 0 ... 10 V
AGND
Reference potential for analog output
Laser on/off
Switching input laser on /off
Zero
Switching input setting mid-point
Switching output 1 Error or limit output
Switching output 2 Limit output
3
4
1
2
12
11
Sync +
Sync - ­1
Tx +
Tx Rx +
Rx -
6
13
1
black
Coaxial screening
red-blue
white-green
gray-pink
violet
Symmetrical synchron output
(Master) or input (Slave)
blue
pink
green
brown
gray
yellow
RS422 - output (symmetrical)
RS422 - input (symmetrical)
1
1) Used as trigger inputs in mode „Triggering“.
2
12
3
5
In case of bore holes, blind holes and
edges in the surface of moving targets
the sensor must be arranged in such a
way that the edges do not obscure the
laser spot.
5
ILD 1700
6
Status „off“
Sensor
pin
PC1700-x
color
Power
supply
5
red
+UB
6
black
GND
14
8
7
6
Normal operation
ILD 1700
Sensor as slave without synchronous signal
UL  0.2 V
I L  0.5 mA
9 (10)
Correct
Use power supply only for measurement
devices. MICRO-EPSILON recommends
the use of the optional available power
supply PS2020 for the sensor.
Switching Inputs Laser On/Off, Setting Masters and Mid-point
Sensor „master“ or „set to mid-point“
Incorrect
(shadow)
UL
6
N-channel Relais/
switch
OpenCollector
IL
Uint
Warnings
Avoid shock and vibration to the sensor. Protect sensor cable against damage.
>> Damage to or destruction of the system, failure of the measuring device
9
13
4
ILD 1700-500/750BL
Avoid continuous exposure to spray on the sensor. Avoid exposure to aggressive materials (washing
agent, penetrating liquids or similar) on the sensor. Mount the sensor only to the existing holes on a
flat surface. Clamps of any kind are not permitted.
>> Damage to or destruction of the sensor
10
11
ILD 1700-40/500/750
Connect the power supply in accordance to the safety regulations for electrical equipment. The
power supply may not exceed the specified limits.
>> Danger of injury, damage to or destruction of the sensor
Power Supply, nominal value: 24 VDC (11 ... 30 V, max. 150 mA).
11 ...
30 VDC
Assembly Instructions
optoNCDT 1700
Coaxial inner conductor, white
View on solder-pin side male cable connector, insulator
...
Selected parameter value matches the
saved value
zero
5
Sensor cable
PC1700-x
red
Comment
Sensor off or laser off
illuminated
Start of measuring range
Setup mode
...
illuminated or
flashing
Designation
Plug connector: ODU MINI-SNAP, 14-pin, series B, dimension 2,
code 0, IP 68; www.odu.de
flashes slowly
output
speed
avg
Pin
The switching inputs for laser on/off and
setting masters/mid-point are similarly
wired. Connect pin 9 with pin 6 in order
to activate the laser. If the connection is
released, the laser is deactivated.
MICRO-EPSILON MESSTECHNIK
GmbH & Co. KG
Koenigbacher Str. 15 · 94496 Ortenburg
www.micro-epsilon.com
*X9771139.01-A07*
X9771139.01-A071129SWE
Proper Use
The optoNCDT1700 is designed for use in industrial areas. It is used for measuring displacement,
distance, position and elongation for in-process quality control and dimensional testing.
The sensor may only be operated within the limits specified in the technical data, see instruction
manual, Chap. 3.4. The sensor should only be used in such a way that in case of malfunctions or
failure personnel or machinery are not endangered. Additional precautions for safety and damage
prevention must be taken for safety-related applications.
Laser Class
The optoNCDT1700 sensors operate with a semiconductor laser with a wavelength of 670 nm (visible/red, ILD 1700) respectively 405 nm (visible/blue, ILD 1700BL).
The following warning labels are attached to the cover (front and/or rear side) of the sensor housing:
LASER RADIATION
Do not stare into the beam
CLASS 2 LASER PRODUCT
IEC 60825-1: 2014
P≤1 mW; λ= 670 nm
IEC label
COMPLIES WITH 21 CFR 1040.10 AND 1040.11
EXCEPT FOR CONFORMANCE WITH
IEC 60825-1 ED. 3., AS DESCRIBED IN
LASER NOTICE NO. 56, DATED MAY 8, 2019
Only for USA
LASER RADIATION
Do not stare into the beam
CLASS 2 LASER PRODUCT
IEC 60825-1: 2014
P≤1 mW; λ= 405 nm
IEC label for ILD1700-x BL only
Never deliberately look into the laser beam! Consciously close your eyes or
turn away immediately if ever the laser beam should hit your eyes.
Quick Guide
Place Target
Components, Typical Application with Analog Output
Switching output 1 Switching output 2
Place the target in the midrange, if possible.
Error output
inactive
The switching output 1 is activated
(conducting to GND),
-- when the target is outside the
measuring range,
-- there is no target present
-- or if the target is unsuitable (too
dark, polished metal, insufficiently
reflective).
Laser On/Off
A
4 ... 20 mA
0 ... 10 V
PC1700-x
D
SPS
PS2020
N
PC1700-x/IF2008
L
Measurement value
EMR
Target
IF2008
230 VAC
Target
Function
-- Setting mid-point
-- No limit control
SMR
Time
GND
+
GND
Components, Typical Application with RS422 and IF2008
The State LED on sensor indicates the position of target to the sensor.
LED
Color
Meaning
off
Laser beam is switched off.
green Sensor in operation, target in measuring range
State
PC1700-x/IF2008
IF2008
-- Power supply sensor
-- Synchronization sensors
-- Laser on/off
Target
Error-Mode (error control, factory setting)
Switch on power supply respectively PC after completion of wiring.
The initialization including the info string transmission takes up to 10 seconds. Within this period,
the sensor neither executes nor replies commands.
To be able to produce reproducible measurements the sensor typically requires a start-up time of
20 minutes.
Change Measurement Value Output
Change the output type with the function/enter and select/zero keys.
Save
parameters
function
enter
LED output
Measurement value
select
zero
mode
red (flashes)
Current output
4 ... 20 mA
function
enter
Voltage output
0 ... 10 VDC
select
zero
RS422
The following 4 values are used:
-- Upper limit (UL), --- Lower limit (LL), --- Upper hysteresis value (UH), --- Lower hysteresis value (LH).
select
zero
Switching output 2
LH
LL
SMR
Time
+
GND
+
Function
-- Mastering
-- Limit control
GND
+
GND
Switching output 1
Switching output 2
SET_UPPERLIMIT F1
Switching output 1
Switching output 2
SET_LOWERLIMIT F1
Please refer to the instruction manual for factory settings to the limit and hysteresis values.
To reset the short-circuit protection:
-- Clear the external short circuit,
Switching output 1/2 -- switch off the sensor and switch on
Pin 7 / 8
again or
-- send the software command „Reset“
to the sensor.
GND Pin 6
The two limit outputs may also be actuated in parallel as window comparator
(OK/Not OK separation).
You can read more information about the sensor in the instruction manual. You will find these online at www.micro-epsilon.de/download/manuals/man--optoNCDT-1700--en.pdf or on the delivered
CD.
Measurement value
GND
max. 100 mA
The transistor T is conductive in the
active state. The switching outputs are
short-circuit-proof.
You will find informations on display and signal processing units online at: www.micro-epsilon.
com/accessories/index.html.
EMR
UL
UH
+
Switching Outputs
green
red
select
zero
Target out of range, too low reflection
Limit value
Limit value
The switching outputs are activated
(conducting to GND),
-- when the target is outside the
measuring range,
-- there is no target present
-- or if a target is unsuitable (too dark,
polished metal, insufficiently reflective).
Change the operating mode of the sensor.
Switching on the Power Supply Respectively PC
LED state
flashes green
red
Operating Mode
is done by the interface card
Measurement
mode
yellow Target is in midrange.
Switching output 1
Switch-Mode (limit control)
Switching output 1 Switching output 2
+24 VDC
ILD1700
T
+
PE
+UB Pin 5