MICRO-EPSILON optoNCDT 1700, 1700BL User manual

Proper Environment -- Protection class: Membrane Keys, LED‘s IP 65 (only with sensor cable connected) Measurement mode (normal operation): -- zero key: Sets the analog output to the value for the midrange, i.e. 5 VDC or 12 mA. Pressing the zero key again resets the function. -- function key: Switches the sensor to setup mode. Lenses are excluded from protection class. Contamination of the lenses leads to impairment or failure of the function. -- Operating temperature: 0 ... 50 °C (+32 up to +122 °F) -- Storage temperature: -20 ... 70 °C (-4 up to +158 °F) -- Humidity: 5 - 95 % (no condensation) -- Ambient pressure: Atmospheric pressure The sensors of the series optoNCDT 1700 are optical sensors with which is measured in the μm area. Make sure that mounting and operation is handled carefully! 18.5 (.73) 80 (3.15) 5 (.20) 70 (2.76) 15 Mount the sensors with three screws type M4. The bearing surfaces surrounding the fastening holes (through holes) are slightly raised. Mounting holes 3 x ø 0.5 mm (.18 dia) 40 (1.57) ø 5 (.20 dia.) (.59) 130 (5.12) 140 (5.51) 150 (5.91) Setup mode (function key actuated): -- function key: For running through the levels and parameters. -- select key: To open the selection list and select the value of the parameter in sequence. -- enter key: For saving the selected parameter value and returning to measurement mode. i 75 (2.95) 101(3.98) 85 (3.35) Pressing and holding the function/enter key for longer than 5 seconds, overwrites all the parameter values with the factory settings (default values). Sensor Mounting 17.5 (.69) 35 (1.38) Dimensional Drawing and Free Space, Measuring Ranges 40/500/750 mm Measuring Ranges 500/750BL 17.5 (.69) If approximately 15 seconds have elapsed since the last press of the function key or 30 seconds since the last press of the select key, the sensor returns to measurement mode without changing the parameters. LED Status Measurement mode illuminated Object is in the measurement range or error off 12 (.47) state 35 (1.38) SMR Inputs and Outputs flashes quickly ... Selected parameter value does not match the saved value off Indication of the parameter values Selected parameter value level 1 flashing red flashing MR Dimensions in mm (inches), not to scale MR = Measuring range SMR = Start of measuring range MMR = Midrange EMR = End of measuring range MR SMR a e 40 175 22.1 ° 21.8 ° 500 200 19.3 ° 7.0 ° 750 200 19.3 ° 5.0 ° +U B 14 9 10 8 7 Power supply (11 ... 30 VDC) System ground for power supply and GND switching signals (Laser on/off, Zero, Limits) Current 4 ... 20 mA or Analog output voltage 0 ... 10 V AGND Reference potential for analog output Laser on/off Switching input laser on /off Zero Switching input setting mid-point Switching output 1 Error or limit output Switching output 2 Limit output 3 4 1 2 12 11 Sync + Sync - 1 Tx + Tx Rx + Rx - 6 13 1 black Coaxial screening red-blue white-green gray-pink violet Symmetrical synchron output (Master) or input (Slave) blue pink green brown gray yellow RS422 - output (symmetrical) RS422 - input (symmetrical) 1 1) Used as trigger inputs in mode „Triggering“. 2 12 3 5 In case of bore holes, blind holes and edges in the surface of moving targets the sensor must be arranged in such a way that the edges do not obscure the laser spot. 5 ILD 1700 6 Status „off“ Sensor pin PC1700-x color Power supply 5 red +UB 6 black GND 14 8 7 6 Normal operation ILD 1700 Sensor as slave without synchronous signal UL 0.2 V I L 0.5 mA 9 (10) Correct Use power supply only for measurement devices. MICRO-EPSILON recommends the use of the optional available power supply PS2020 for the sensor. Switching Inputs Laser On/Off, Setting Masters and Mid-point Sensor „master“ or „set to mid-point“ Incorrect (shadow) UL 6 N-channel Relais/ switch OpenCollector IL Uint Warnings Avoid shock and vibration to the sensor. Protect sensor cable against damage. >> Damage to or destruction of the system, failure of the measuring device 9 13 4 ILD 1700-500/750BL Avoid continuous exposure to spray on the sensor. Avoid exposure to aggressive materials (washing agent, penetrating liquids or similar) on the sensor. Mount the sensor only to the existing holes on a flat surface. Clamps of any kind are not permitted. >> Damage to or destruction of the sensor 10 11 ILD 1700-40/500/750 Connect the power supply in accordance to the safety regulations for electrical equipment. The power supply may not exceed the specified limits. >> Danger of injury, damage to or destruction of the sensor Power Supply, nominal value: 24 VDC (11 ... 30 V, max. 150 mA). 11 ... 30 VDC Assembly Instructions optoNCDT 1700 Coaxial inner conductor, white View on solder-pin side male cable connector, insulator ... Selected parameter value matches the saved value zero 5 Sensor cable PC1700-x red Comment Sensor off or laser off illuminated Start of measuring range Setup mode ... illuminated or flashing Designation Plug connector: ODU MINI-SNAP, 14-pin, series B, dimension 2, code 0, IP 68; www.odu.de flashes slowly output speed avg Pin The switching inputs for laser on/off and setting masters/mid-point are similarly wired. Connect pin 9 with pin 6 in order to activate the laser. If the connection is released, the laser is deactivated. MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Koenigbacher Str. 15 · 94496 Ortenburg www.micro-epsilon.com *X9771139.01-A07* X9771139.01-A071129SWE Proper Use The optoNCDT1700 is designed for use in industrial areas. It is used for measuring displacement, distance, position and elongation for in-process quality control and dimensional testing. The sensor may only be operated within the limits specified in the technical data, see instruction manual, Chap. 3.4. The sensor should only be used in such a way that in case of malfunctions or failure personnel or machinery are not endangered. Additional precautions for safety and damage prevention must be taken for safety-related applications. Laser Class The optoNCDT1700 sensors operate with a semiconductor laser with a wavelength of 670 nm (visible/red, ILD 1700) respectively 405 nm (visible/blue, ILD 1700BL). The following warning labels are attached to the cover (front and/or rear side) of the sensor housing: LASER RADIATION Do not stare into the beam CLASS 2 LASER PRODUCT IEC 60825-1: 2014 P≤1 mW; λ= 670 nm IEC label COMPLIES WITH 21 CFR 1040.10 AND 1040.11 EXCEPT FOR CONFORMANCE WITH IEC 60825-1 ED. 3., AS DESCRIBED IN LASER NOTICE NO. 56, DATED MAY 8, 2019 Only for USA LASER RADIATION Do not stare into the beam CLASS 2 LASER PRODUCT IEC 60825-1: 2014 P≤1 mW; λ= 405 nm IEC label for ILD1700-x BL only Never deliberately look into the laser beam! Consciously close your eyes or turn away immediately if ever the laser beam should hit your eyes. Quick Guide Place Target Components, Typical Application with Analog Output Switching output 1 Switching output 2 Place the target in the midrange, if possible. Error output inactive The switching output 1 is activated (conducting to GND), -- when the target is outside the measuring range, -- there is no target present -- or if the target is unsuitable (too dark, polished metal, insufficiently reflective). Laser On/Off A 4 ... 20 mA 0 ... 10 V PC1700-x D SPS PS2020 N PC1700-x/IF2008 L Measurement value EMR Target IF2008 230 VAC Target Function -- Setting mid-point -- No limit control SMR Time GND + GND Components, Typical Application with RS422 and IF2008 The State LED on sensor indicates the position of target to the sensor. LED Color Meaning off Laser beam is switched off. green Sensor in operation, target in measuring range State PC1700-x/IF2008 IF2008 -- Power supply sensor -- Synchronization sensors -- Laser on/off Target Error-Mode (error control, factory setting) Switch on power supply respectively PC after completion of wiring. The initialization including the info string transmission takes up to 10 seconds. Within this period, the sensor neither executes nor replies commands. To be able to produce reproducible measurements the sensor typically requires a start-up time of 20 minutes. Change Measurement Value Output Change the output type with the function/enter and select/zero keys. Save parameters function enter LED output Measurement value select zero mode red (flashes) Current output 4 ... 20 mA function enter Voltage output 0 ... 10 VDC select zero RS422 The following 4 values are used: -- Upper limit (UL), --- Lower limit (LL), --- Upper hysteresis value (UH), --- Lower hysteresis value (LH). select zero Switching output 2 LH LL SMR Time + GND + Function -- Mastering -- Limit control GND + GND Switching output 1 Switching output 2 SET_UPPERLIMIT F1 Switching output 1 Switching output 2 SET_LOWERLIMIT F1 Please refer to the instruction manual for factory settings to the limit and hysteresis values. To reset the short-circuit protection: -- Clear the external short circuit, Switching output 1/2 -- switch off the sensor and switch on Pin 7 / 8 again or -- send the software command „Reset“ to the sensor. GND Pin 6 The two limit outputs may also be actuated in parallel as window comparator (OK/Not OK separation). You can read more information about the sensor in the instruction manual. You will find these online at www.micro-epsilon.de/download/manuals/man--optoNCDT-1700--en.pdf or on the delivered CD. Measurement value GND max. 100 mA The transistor T is conductive in the active state. The switching outputs are short-circuit-proof. You will find informations on display and signal processing units online at: www.micro-epsilon. com/accessories/index.html. EMR UL UH + Switching Outputs green red select zero Target out of range, too low reflection Limit value Limit value The switching outputs are activated (conducting to GND), -- when the target is outside the measuring range, -- there is no target present -- or if a target is unsuitable (too dark, polished metal, insufficiently reflective). Change the operating mode of the sensor. Switching on the Power Supply Respectively PC LED state flashes green red Operating Mode is done by the interface card Measurement mode yellow Target is in midrange. Switching output 1 Switch-Mode (limit control) Switching output 1 Switching output 2 +24 VDC ILD1700 T + PE +UB Pin 5
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement