Chore-Time MT1828B Air Speed Sensor Installation & Operator's Instruction Manual

Add to My manuals
6 Pages

advertisement

Chore-Time MT1828B Air Speed Sensor Installation & Operator's Instruction Manual | Manualzz

Air Speed Sensor

Installation & Operator’s Instruction Manual

Introduction

The Airspeed Sensor is used to measure the air speed in a tunnel ventilated building. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury.

Safety

DANGER ! Electrical Hazard

Disconnect electrical power to the

Control and to ALL electrical devices connected to the Control's

Relay Box before installing the update kit! Failure to disconnect power to equipment connected to

Relay Box could result in personal injury.

May 2017 MT1828B

2

CTB Inc. Warranty Air Speed Sensor

CTB Inc. Warranty

CTB Inc.

warrants each new product manufactured by it to be free from defects in material or workmanship for one year from and after the date of initial installation by or for the original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. Labor costs associated with the replacement or repair of the product are not covered by the Manufacturer.

Conditions and Limitations

1. The product must be installed by and operated in accordance with the instructions published by the

Manufacturer or Warranty will be void .

2. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer .

3. This product must be purchased from and installed by an authorized distributor or certified representative thereof or the Warranty will be void.

4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty.

5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty.

The Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies.

THIS WARRANTY CONSTITUTES THE MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND

THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES,

INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO

MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR

QUALITY OF THE PRODUCT FURNISHED HEREUNDER.

CTB Inc. product Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for CTB Inc. products in addition to those terms expressly stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models.

Effective: May 2017

Thank You

The employees of CTB Inc. would like to thank your for your recent purchase. If a problem should arise, your CTB distributor can supply the necessary information to help you.

MT1828B

Air Speed Sensor Assembly

Assembly

Attach the Airspeed Sensor (Item 1, Figure 1) to the Mounting Bracket (Item 2) using the nuts and washers attached to the Sensor itself.

1

2

1

1

2

3

Item Description

1 Air Speed Sensor

4

Mounting Bracket

Washer (provided)

Nut (Provided)

Figure 1. Air Speed Sensor Assembly

Attach the Mounting Bracket (Item 1, Figure 2) to a 2" x 4" board (Item 2) using 

(3) #8 screws (Item 3) provided. It is recommended that the board be connected to the ceiling using a Hinge (not provided). This is to allow the Sensor to be lifted out of the way during cleanout.

4

2

MT1828B

1

3

Figure 2. Air Speed Sensor Mounting

2

3

Item Description

1 Mounting Bracket

4

2x4 Board

#8 Screw

Hinge (Not provided)

3

Assembly Air Speed Sensor

The Air Speed Sensor (Item 1, Figure 3) should be located approximately 50 feet from the Tunnel Fans, 3 feet off the floor in the center of the building. Do not mount the Sensor to the wall. The Sensor needs to have a rigid mounting for a more accurate airspeed measurement. The Airspeed Sensor should be oriented so that the axis of the Sensor is vertical and the three plastic cups spin horizontally.

Approx. 50’ [15.2 Meters]

Axis Vertical

1

Center of House

1

Floor

3’ [1 Meter]

Tunnel

Fans

Item Description

1 Air Speed Sensor

Figure 3. Air Speed Sensor location

4 MT1828B

Wiring

The Airspeed Translation Box can be placed anywhere in line between the Control and the

Sensor. Recommended locations would be either right next to the Control or mounted on the Mounting Bracket of the Sensor.

2 (DI) of your Choice

DI1 12V

3

GREEN

BROWN

WHITE

1

GREEN

BROWN

WHITE

Item

1

2

3

Description

Airspeed Sensor

I/O Board Digital Input (DI) terminal of your Choice

Airspeed Translation Box

Parts List

2

Item Description

1 Air Speed Sensor

Part No.

49350

2 Mounting Bracket 49351

1

Page No.

Made to work.

Built to last.

Revisions to this Manual

Description of Change ECO

Added Wiring Diagram 32672

Contact your nearby Chore-Time distributor or representative for additional parts and information.

CTB Inc.

P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.

Phone (574) 658-4101 • Fax (877) 730-8825

Email: [email protected] • Internet: http//www.ctbinc.com

advertisement

Related manuals

Download PDF

advertisement