Chore-Time MV1738A TURBO-COOL™ Sump Inlet Repair Kit Instruction

Add to my manuals
2 Pages

advertisement

Chore-Time MV1738A TURBO-COOL™ Sump Inlet Repair Kit Instruction | Manualzz

Turbo-Cool ™ Sump Inlet Repair Kit (48202)

Instruction

Thank You

The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should arise, your Chore-Time distributor can supply the necessary information to help you.

Installation

Turn off the water supply and remove the supply hose.

If possible, mark the position of the Water Inlet Pipe to make it easier for resetting float height after installation of the new Inlet Pipe Support Bracket.

Remove the Stainless Steel Hose Clamp.

Using a Utility Knife, remove the old Spinweld Fitting (Item 1, Figure 1) . Be careful not to cut deep enough to damage the Inlet Pipe. (Item 2)

1 2

Item Description

1 Spinweld Fitting

2 Inlet Pipe

Figure 1. Removing Spinweld Fitting

Place the Inlet Pipe Support Bracket (Item 1, Figure 2) over the Inlet Pipe (Item 2) . Wrap the Stainless Steel Hose

Clamp around the Inlet Pipe and through the slots in the back of the Inlet Pipe Support Bracket (Item 3) as shown .

2 1

3

Slots in Inlet Pipe Support Bracket

Item Description

1 Inlet Pipe Support Bracket

2 Inlet Pipe

3 SS Hose Clamp

Figure 2. Inlet Pipe Support Installation

September 2003

MV1738A

Installation Turbo-Cool™ Sump Inlet Repair Kit (48202) Instruction

Using the holes in the Inlet Pipe Support Bracket for a guide, Drill four 1/4" holes in the Sump (See Figure 3 below) .

Use the supplied Bolts, Nuts and Washers to secure the Inlet Pipe Support Bracket to the Sump.

3

1

5

2

Item Description

1 Inlet Pipe Support Bracket

2

3

Sump

Bolt

4

5

Washer

Nut

4

Figure 3. Inlet Pipe Support Installation

Once the Inlet Pipe is in the proper position tighten down the Stainless Steel Hose Clamp. Make sure the Float Ball moves freely. Reconnect the hose and reset the Water Inlet Pipe to it’s original position. Turn on the water supply.

See Turbo-Cool Manual for setting water level height.

CTB Inc.

P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.

Phone (574) 658-4101 • Fax (877) 730-8825

E-Mail: [email protected] • Internet: http//www.ctbinc.com