Chore-Time MV1738A TURBO-COOL™ Sump Inlet Repair Kit is designed to fix damaged sump inlets, allowing for easy water supply reconnection and water level height adjustment. This kit includes a new spinweld fitting, inlet pipe support bracket, bolts, nuts, washers, and a stainless steel hose clamp. Installation involves removing the old spinweld fitting, positioning the new inlet pipe support bracket, drilling holes in the sump, securing the bracket, and reconnecting the water supply. Remember to refer to the Turbo-Cool Manual for precise water level height settings.
advertisement
Turbo-Cool ™ Sump Inlet Repair Kit (48202)
Instruction
Thank You
The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should arise, your Chore-Time distributor can supply the necessary information to help you.
Installation
Turn off the water supply and remove the supply hose.
If possible, mark the position of the Water Inlet Pipe to make it easier for resetting float height after installation of the new Inlet Pipe Support Bracket.
Remove the Stainless Steel Hose Clamp.
Using a Utility Knife, remove the old Spinweld Fitting (Item 1, Figure 1) . Be careful not to cut deep enough to damage the Inlet Pipe. (Item 2)
1 2
Item Description
1 Spinweld Fitting
2 Inlet Pipe
Figure 1. Removing Spinweld Fitting
Place the Inlet Pipe Support Bracket (Item 1, Figure 2) over the Inlet Pipe (Item 2) . Wrap the Stainless Steel Hose
Clamp around the Inlet Pipe and through the slots in the back of the Inlet Pipe Support Bracket (Item 3) as shown .
2 1
3
Slots in Inlet Pipe Support Bracket
Item Description
1 Inlet Pipe Support Bracket
2 Inlet Pipe
3 SS Hose Clamp
Figure 2. Inlet Pipe Support Installation
September 2003
MV1738A
Installation Turbo-Cool™ Sump Inlet Repair Kit (48202) Instruction
Using the holes in the Inlet Pipe Support Bracket for a guide, Drill four 1/4" holes in the Sump (See Figure 3 below) .
Use the supplied Bolts, Nuts and Washers to secure the Inlet Pipe Support Bracket to the Sump.
3
1
5
2
Item Description
1 Inlet Pipe Support Bracket
2
3
Sump
Bolt
4
5
Washer
Nut
4
Figure 3. Inlet Pipe Support Installation
Once the Inlet Pipe is in the proper position tighten down the Stainless Steel Hose Clamp. Make sure the Float Ball moves freely. Reconnect the hose and reset the Water Inlet Pipe to it’s original position. Turn on the water supply.
See Turbo-Cool Manual for setting water level height.
CTB Inc.
P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax (877) 730-8825
E-Mail: [email protected] • Internet: http//www.ctbinc.com
Printed in the U.S.A.