Sundance Spas 880™ Series 2012 Owner Manual

Add to My manuals
90 Pages

advertisement

Sundance Spas 880™ Series 2012 Owner Manual | Manualzz

8 8 0

Altamar™ | Aspen™ | Cameo™ | Capri™

Majesta™ | Marin™ | Maxxus™ | Optima™

o w n e r ’ s m a n u a l

6530-395Y Rev. A

Attention New Hot Tub Owner!

Congratulations on the purchase of your new Sundance hot tub! The following is a list of automated functions performed by your hot tub. These functions are listed below in an attempt to suppress any operational concerns you may have during the first 24-hours of ownership! Also listed below are important maintenance recommendations you should observe on a regular basis to protect your new investment.

Automated Spa Operations

Your new hot tub is equipped with an automated “blow-out” cycle that clears all plumbing lines daily to promote maximum water sanitation. Each day at 12:00

PM (noon), pump 2, pump 3 (Maxxus™/Aspen™ Models) and the blower will automatically turn on for a period of one minute, then go off. Then pump 1 will turn on and run for one minute to complete the blow-out cycle. Be aware, the factory programmed blow-out cycle cannot be canceled or altered!

Maintain Healthy Spa Water

Always maintain your hot tub’s water chemistry within the following parameters:

pH

Free chlorine

Free Bromine

Total Alkalinity

Calcium Hardness

With CLEARRAY™

7.4-7.6

no less than 1.0 ppm no less than 2.0 ppm

100-120 ppm

150-250 ppm

Without CLEARRAY™

7.4-7.6

3.0-4.0 ppm

2.0-4.0 ppm

100-120 ppm

150-250 ppm

IMPORTANT:

CLEARRAY™ Water Purification System is factory installed. If the CLEARRAY™ system is altered or is not operating efficiently follow the

“without CLEARRAY™” water chemistry parameters. Such parameters are defined by the Association of Pool and Spa Professionals. CLEARRAY™ requires an annual lamp replacement to properly sanitize your water.

!

TO dECREASE RISk OF INFECTION OR dISEASE!

Always maintain your spa filter as outlined below to ensure healthy spa water. Refer to

pages 61

-

6 2 for additional information.

Required Filter Maintenance

Your new hot tub is equipped with an advanced MICROCLEAN® Ultra water filtration system that provides unsurpassed water quality! To ensure maximum water quality at all times, you should replace the filter cartridge every six months, or earlier as necessary. The filter cartridge is designed to be thrown away!

Attempts to reuse the filter cartridge may result in the re-release of unwanted

particles back into the hot tub. See pages 61

6 2 for detailed filter cartridge

replacement instructions.

Required Water Replacement

!

TO dECREASE RISk OF INFECTION OR dISEASE!

You should replace the hot tub’s water every 3 to 6 months. The frequency depends on a number of variables including frequency of use, number of users, and attention paid to water quality maintenance. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water, even though the key water balance measurements are all within the

proper parameters. See pages 69

-

7 0 for additional information.

880 SERIES

Table of Contents

1.0 Important Hot Tub Owner Information ............................1

2.0 FCC Notice ........................................................................1

3.0 Important Safety Instructions for all Spa Owners .........2

3.1 Entrapment Risk .......................................................................... 6

3.2 Hyperthermia ............................................................................... 7

3.3 Important Additional CSA Safety Instructions (Canada Only) ...... 8

4.0 Locating Your Sundance Hot Tub ...................................9

4.1 Outdoor Location ....................................................................... 1 0

4.2 Indoor Location .......................................................................... 1 0

5.0 General Electrical Safety Instructions ..........................11

6.0 Electrical Installation Instructions (240V Service) .......12

7.0 Power Requirements ......................................................15

7.1 North American 60 Hz Power Options ....................................... 15

7.2 Export 50 Hz Power Options ...................................................... 16

8.0 Hot Tub Fill Up Procedure ..............................................17

9.0 Hot Tub Features ............................................................22

9.1 Main Control Panel Functions (except Capri Models)................

22

9.2 Main Control Panel Functions (Capri Models Only) ...................

23

9.3 LCD Screen Functions ...............................................................

24

9.4 Maxxus Hot Tub Features ..........................................................

2 5

9.5 Maxxus Massage/Waterfall Selector Diagram ...........................

2 6

9.6 Maxxus Air Controls Diagram ....................................................

2 7

9.7 Aspen Hot Tub Features ............................................................

2 8

9.8 Aspen Massage/Waterfall Selector Diagram .............................

2 9

9.9 Aspen Air Controls Diagram .......................................................

30

9.10 Optima Hot Tub Features ...........................................................

3 1

9.11 Optima Massage/Waterfall Selector Diagram ............................

32

9.12 Optima Air Controls Diagram .....................................................

33

9.13 Cameo Hot Tub Features ...........................................................

34

9.14 Cameo Massage/Waterfall Selector Diagram ............................

3 5

9.15 Cameo Air Controls Diagram .....................................................

3 6

9.16 Altamar Hot Tub Features ..........................................................

3 7

© Sundance Spas, Inc. All Rights Reserved

880 SERIES

9.17 Altamar Massage/Waterfall Selector Diagram ...........................

3 8

9.18 Altamar Air Controls Diagram ....................................................

3 9

9.19 Majesta Hot Tub Features ..........................................................

40

9.20 Majesta Massage/Waterfall Selector Diagram ...........................

4 1

9.21 Majesta Air Controls Diagram ....................................................

42

9.22 Marin Hot Tub Features .............................................................

43

9.23 Marin Massage/Waterfall Selector Diagram ..............................

44

9.24 Marin Air Controls Diagram ........................................................

4 5

9.25 Capri Hot Tub Features ..............................................................

4 6

9.26 Capri Massage/Waterfall Selector Diagram ...............................

4 7

9.27 Capri Air Controls Diagram ........................................................

4 8

10.0 Operating Instructions ...................................................49

10.1 View Button ................................................................................

4 9

10.2 Air Injection ................................................................................

4 9

10.3 Controlling the water temperature ..............................................

4 9

10.4 Activate Jets Pump 1 ................................................................. 5 0

10.5 Activate Jets Pump 2/Pump 3 .................................................... 5 0

10.6 Light Button (Except Capri Model) ............................................. 5 0

10.7 Light Button (Main Control Panel; Capri Model Only) ................ 51

10.8 AquaTerrace™ Light Control Panel (Capri Model Only) ............ 51

10.9 Selecting The Desired Massage Action ..................................... 5 2

10.10 Adjusting Fluidix Reflex, Nex, ST, Intelli-Jets And Focus-Relief ......5

2

10.11 Air Controls ................................................................................ 5 3

10.12 Waterfall Control ........................................................................ 5 3

10.13 Fragrance Dispenser ................................................................. 5 3

10.14 Indicator Light ............................................................................ 5 4

10.15 Optional Audio System ............................................................... 5 4

11.0 Heating Modes ................................................................54

11.1 Standard Mode (Factory Default) ............................................... 5 4

11.2 Economy Mode .......................................................................... 5 4

11.3 Selecting Standard or Economy Mode ...................................... 5 4

11.4 Clean-Up “Blow-Out” Cycle ........................................................ 55

12.0 Programming Instructions .............................................55

12.1 Programming Filter/Circulation Pump ........................................ 55

12.2 Programmable Filter/Heating Cycles (Economy Mode Only) .... 56

12.3 Adjusting Time of Day ................................................................ 57

12.4 Programming The Date .............................................................. 58

12.5 Main Control Panel Lock ............................................................ 58

12.6 Temperature Setting Lock .......................................................... 58

880 SERIES

12.7 Programming the Change Filter Reminder ................................ 59

1 2.8 Programming the CLEARRAY™ (Ultraviolet)

Water Purification System .......................................................... 59

13.0 Hot Tub Maintenance ......................................................61

13.1 Cleaning/Replacing the Filter Cartridge ..................................... 61

13.2 Quick Release Door (Except Maxxus and Aspen Models) ........ 6 3

13.3 Draining And Refilling ................................................................. 6 4

13.4 Cleaning The Hot Tub Interior .................................................... 65

13.5 Pillow Care (except Capri model) .............................................. 65

13.6 Pillow Care (Capri model only) .................................................. 66

13.7 Maintaining the Hot Tub Cabinet ................................................ 66

13.8 Vinyl Cover Care And Maintenance ........................................... 67

13.9 Winterizing ................................................................................. 67

13.10 Restarting Your Hot Tub in Cold Weather .................................. 68

14.0 Water Quality Maintenance ............................................69

14.1 pH Control .................................................................................. 69

14.2 Sanitizing ................................................................................... 69

14.3 CLEARRAY™ Water Purification System .................................. 7 0

14.4 CLEARRAY™ Lamp Replacement and Quartz

Tube Maintenance ..................................................................... 71

14.5 Other Additives ........................................................................... 7 3

14.6 Handrail Maintenance ................................................................ 7 3

15.0 Troubleshooting - display Messages ...........................74

16.0 Troubleshooting - Procedures .......................................77

17.0 North American 60 Hz Electrical Wiring diagram ........79

17.1 North American 60 Hz Maxxus/Aspen Electrical

Wiring Diagram .......................................................................... 79

17.2 North American 60 Hz Altamar/Cameo/Capri/Majesta/

Marin Electrical Wiring Diagram ................................................. 8 0

18.0 Export 50 Hz Electrical Wiring diagram .......................81

18.1 Export 50 Hz Maxxus/Aspen Electrical Wiring Diagram ............ 81

18.2 Export 50 Hz Altamar/Cameo/Capri/Majesta/Marin

Electrical Wiring Diagram ........................................................... 8 2

19.0 Circuit Board Pin Assignments .....................................83

20.0 Typical Hot Tub Wiring diagrams A-B

(North American 60 Hz Models Only) ............................84

.

880 SERIES

1.0 Important Hot Tub Owner Information

Your Sundance

®

hot tub is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the hot tub for efficient operation, an uncovered hot tub surface and wall fittings directly exposed to sunlight and high temperatures for an extended period are subject to permanent damage or discoloration. Damage caused by exposing the hot tub to this abuse is not covered under warranty. We recommend that you always keep the hot tub full of water when it is exposed to direct sunlight and that you keep the Sundance insulating cover in place at all times when the hot tub is not in use. Read and carefully follow the requirements for your hot tub’s support base found in the Section 4.0 titled, “Locating Your Sundance Hot Tub” (page

9) or as

prescribed by your authorized Sundance Spas dealer.

Sundance hot tubs constantly strives to offer the finest hot tubs available, therefore, modifications and enhancements may be made which affect the specifications, illustrations and/or instructions contained herein.

2.0 FCC Notice

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

1. Rearrange or relocate the receiving antenna;

2. Increase the separation between the equipment and receiver;

3. Connect the equipment into an outlet on a circuit different from the circuit connected;

4. Consult the dealer or an experienced radio/TV technician for help.

(Changes or modifications not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate this equipment).

Page 1

880 SERIES

3.0 Important Safety Instructions for all Spa Owners

REAd ANd FOLLOW ALL INSTRUCTIONS CAREFULLY!

This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB

Safety Act). When installing and using this spa, basic safety precautions should always be followed, including:

1.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

Extreme caution must be exercised to prevent unauthorized access by children.

To avoid accidents, ensure that children do not use this spa unless supervised at all times. Adult supervision is a critical safety factor in preventing children from drowning.

Use the straps and clip tie downs to secure the spa cover when not in use. This will help discourage unsupervised children from entering the spa. Keep the spa cover secure in high-wind conditions.

There is no representation that the cover, clip tie-downs, or actual locks will prevent access to the spa.

2.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

Keep hair, loose articles of clothing or hanging jewelry away from suction fittings, rotating jets or other moving components to avoid entrapment that could lead to drowning or severe injury.

Never use the spa unless all suction guards, filter, filter lid, or skimmer assembly are installed to prevent body and/or hair entrapment.

Never operate or use the spa if the filter, filter lid, or skimmer assembly are broken or any part of the skimmer assembly is missing.

Please contact your dealer or nearest service center for service.

The suction fittings and suction covers in this spa are sized to match the specific water flow created by the pump(s). If it is necessary to replace the suction fittings, suction covers or pump(s), be sure that the flow rates are compatible and are in compliance with the VGB Safety Act.

Never replace a suction fitting or suction cover with one rated less than the flow rate marked on the original suction fitting. Using improper suction fittings or suction covers can create a body or hair suction entrapment hazard that may lead to drowning or severe injury.

3.

!

dANGER:

RISk OF SEVERE INjURY FROM ELECTRIC

SHOCk OR dEATH FROM ELECTROCUTION!

Install the spa at least 5 feet (1.5m), from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected (bonded) by a minimum No. 8 AWG (8.4 mm²) solid copper conductor attached to the wire connector on the grounding lug, inside the equipment compartment on the equipment box.

Page 2

880 SERIES

4.

5.

A grounding wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.

Never permit any electrical appliance, such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a spa unless such appliances are built-in by the manufacturer.

Never bring any electrical appliances into or near the spa.

Never operate any electrical appliances from inside the spa or when you are wet.

The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with section 422-20 of the National Electrical Code/

USA, ANSI/NFPA 70. The disconnecting means must be readily accessible and visible to the spa occupant but installed at least 5 feet (1.5m), from the spa.

The electrical circuit supplied for the hot tub must include a suitable ground fault circuit interrupter (GFCI) as required by NEC Article

680-42.

!

WARNING:

RISk OF SEVERE INjURY OR dEATH!

Extreme caution must be exercised to prevent diving or jumping into the spa or slipping and falling, which could result in unconsciousness, drowning, or serious injury. Remember that wet surfaces can be very slippery.

Never stand, walk or sit on the top railing of the spa.

!

WARNING:

RISk OF HYPERTHERMIA (OVER-HEATING)

CAUSING SEVERE INjURY, BURNS, WELTS OR dEATH!

Water temperature in excess of 104°F (40°C) may be injurious to your health.

Refer to Section 3.2 Hyperthermia for specific causes and symptoms of this condition.

The water in the spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.

Lower water temperatures are recommended for young children

(children are especially sensitive to hot water) and when spa use may exceed 10 minutes.

The Consumer Products Safety Commission/USA has stated that the water temperature in a spa should not exceed 104°F (40°C).

Always test the spa water temperature before entering the spa.

The user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices may vary as much as +/- 5°F (2°C).

Page 3

880 SERIES

6.

7.

8.

!

WARNING:

RISk OF SEVERE INjURY OR dEATH!

Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, if pregnant or possibly pregnant, consult your physician before using a spa.

Pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).

Persons suffering from obesity or a medical history of heart disease, low or high blood pressure, circulatory system problems, diabetes, infectious diseases or immune deficiency syndromes should consult a physician before using a spa.

If you experience breathing difficulties in association with using or operating your spa, discontinue use and consult your physician.

Persons using medication should consult a physician before using a spa since some medication may induce drowsiness, while other medication may affect heart rate, blood pressure, and circulation.

Persons suffering from any condition requiring medical treatment, the elderly, or infants should consult with a physician before using a spa.

The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.

!

WARNING:

RISk OF SEVERE INjURY OR dEATH!

Prolonged immersion in a spa may be injurious to your health.

Observe a reasonable time limit when using the spa. Exposures at higher temperatures can cause high body temperature (overheating). Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly result in drowning or serious injury.

Never use a spa immediately following strenuous exercise. Enter and exit the spa slowly. Wet surfaces can be slippery.

!

WARNING:

TO dECREASE RISk OF INFECTION OR dISEASE!

To reduce the risk of contracting a waterborne illness (e.g. an infec tion, bacteria or virus) and/or respiratory ailments , maintain water chemistry within the parameters listed on the inside cover of this manual and consult with a licensed engineer regarding proper venti lation if installed indoors or in an enclosed area.

People with infectious diseases should not use a spa to avoid water contamination, which could result in spreading infections to others.

Always shower before and after using your spa. Maintain water chemistry in accordance with manufacturer’s instructions. Failure to do so may result in contracting a waterborne illness (e.g. an infec tion, bacteria or virus).

Page 4

880 SERIES

9.

!

WARNING:

In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments that could be present in the air or water.

Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.

10.

CAUTION: TO dECREASE RISk OF PROdUCT dAMAGE.

• Maintain water chemistry in accordance with manufacturer’s

• instructions.

Proper chemical maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components.

11.

!

WARNING:

RISk OF SEVERE INjURY OR dEATH!

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

12.

NOTE:

This spa is not intended nor designed to be used in a commercial or public application. The spa buyer shall determine whether there are any code restrictions on the use or installation of this spa since local code requirements vary from one locality to another.

Hot Tub Safety Literature

To ensure you have a safe and enjoyable hot tub experience, learn all you can about hot tub safety and emergency procedures.

Especially useful are the brochures listed below:

Children Aren’t Waterproof

Conduct your own search on the internet

Write to the following address:

The Association of Pool and Spa Professionals

2111 Eisenhower Avenue

Alexandria VA 22314

703.838.0083

Pool and Spa Emergency Procedures For Infants and Children

Layers of Protection

The Sensible Way to Enjoy Your Spa or Hot Tub

The Association of Pool and Spa Professionals publishes these brochures. To acquire a brochure:

Ask your hot tub dealer (they may have copies)

Go to http://www.apsp.org

Page 5

880 SERIES

3.1 Entrapment Risk

The Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drain and/or suction fittings causing death, drowning, or serious injury (see diagram below). This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act”

(VGB Safety Act). Entrapment risk can be minimized if proper precautions are taken.

!

dANGER:

RISk OF PERSONAL INjURY OR dEATH

!

Never operate the spa if a suction fitting, suction cover, filter, filter lid or skimmer assembly are broken, damaged or missing.

Filter, Filter

Lid, Skimmer

Assembly

(location and style vary by models)

Suction Fittings,

Suction Covers

(locations vary by models)

1.

2.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

Hair entrapment

: May occur if hair is entangled, knotted or snagged in a drain suction or skimmer assembly. This has been reported in persons who when submerge themselves underwater, allowing hair to come close and/or within the reach of the suction fittings, suction covers or skimmer assembly.

Keep hair away from suction fittings, suction covers, filter, filter lid or skimmer assembly.

Children are at risk for hair entrapment if swimming under water.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

Limb entrapment

: May occur when a limb becomes entrapped, inserted or sucked into a suction or outlet opening.

Always keep suction fittings, suction covers, filter, filter lid or skimmer assembly in place when operating to avoid limb entrapment.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

Page 6

880 SERIES

3.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

Body entrapment

: May occur when part of the torso becomes entrapped, inserted or sucked into a suction or outlet opening.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

4.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

Evisceration (disembowelment) entrapment

: May occur when the buttocks becomes entrapped, inserted or sucked into a suction or outlet opening.

Never sit on suction fittings, suction covers, filter, filter lid or skimmer assembly.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

5.

Mechanical entrapment

: May occur when jewelry, swimsuit, or

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING!

hair accessories become entangled, knotted or snagged in a drain suction or skimmer assembly.

Never allow your jewelry, swimsuit, or hair accessories to come close to the suction fittings, suction covers or skimmer assembly.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

3.2 Hyperthermia

Prolonged immersion in hot water may induce hyperthermia (overheating). The use of alcohol or drugs can greatly increase the risk of fatal hyperthermia in spas. A description of the causes, symptoms, and effects of hyperthermia are as follows:

Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F

(37°C). The symptoms of hyperthermia include drowsiness, lethargy

(fatigue), and an increase in the internal temperature of the body (feeling of being too hot). The effects of hyperthermia include:

• Unawareness of impending hazard;

• Failure to perceive heat;

• Failure to recognize the need to exit spa;

• Physical inability to exit spa;

• Fetal damage in pregnant women; and

• Unconsciousness and danger of drowning.

A Warning Sign is provided in your warranty packet. Please install at a location near your spa, where it is visible to users of the spa. For additional or replacement Warning Signs please contact your local

Sundance spas dealer and reference item number #6530-082.

Page 7

880 SERIES

3.3 Important Additional CSA Safety Instructions (Canada Only)

When using this electrical equipment, basic safety precautions should always be followed, including the following:

1.

REAd ANd FOLLOW ALL INSTRUCTIONS.

2. A green colored terminal or a terminal marked G, Gr, Ground,

Grounding or the symbol* is located inside the supply termi nal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equiva lent in size to the circuit conductors that supply this equipment (*IEC

Publication 417, Symbol 5019).

3. At least two lugs marked “Bonding Lugs” are provided on the external surface or on the inside of the supply terminal box/compartment.

To reduce the risk of electric shock, connect the local common bond ing grid in the area of the spa to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG (10 mm²).

4. All field installed metal components such as rails, ladders, drains or other similar hardware within 10 feet (3m) of the spa shall be bonded to the equipment grounding buss with copper conductors not smaller than No. 6 AWG (10 mm²).

5.

SAVE THESE INSTRUCTIONS.

Page 8

880 SERIES

4.0 Locating Your Sundance Hot Tub

IMPORTANT:

Because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is in place. If the spa is placed on a surface which does not meet these requirements, damage to the skirt and/or the spa shell may result.

Damage caused by improper support is not covered under warranty.

It is the responsibility of the spa owner to assure the integrity of the support over time. We recommend a poured, reinforced concrete slab with a minimum thickness of 4 inches (10 cm). Wood decking is also acceptable provided it is constructed so that it meets the requirements outlined above.

!

WARNING:

For spas that are to rest on balconies, roofs or other platforms not specifically tied into main structural support, consult a professional Structural Engineer with experience in this type of application.

The spa must be installed in such a manner as to provide drainage away from it. Placing the spa in a depression without provisions for proper drainage could allow rain, overflow and other casual water to flood the equipment and create a wet condition in which it would sit in. For spas which will be recessed into a floor or deck, install so as to permit access to the equipment, either from above or below, for servicing. Make certain that there are no obstructions which would prevent removal of all side cabinet panels and access to components, especially on the side with the equipment bay doors.

CAUTION:

If the spa is indoors or located in an enclosed area, proper ventilation should be discussed with an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and air associated with chemical odors outdoors.

When the spa is in use considerable amounts of moisture will escape potentially causing mold and mildew.

This can cause health risk. Over time, this can damage certain surfaces, surroundings, and equipment.

Page 9

880 SERIES

4.1 Outdoor Location

In selecting the ideal outdoor location for your hot tub, we suggest that you take into consideration the following:

• The proximity to changing area and shelter (especially in regions

• subject to cold weather).

The pathway to and from your hot tub (this should be free of debris so that dirt and leaves are not easily tracked into the hot tub).

The closeness to trees and shrubbery (remember that leaves and birds could create extra work in keeping the hot tub clean).

A sheltered environment (less wind and weather exposure can result in lowered operation and maintenance costs).

The overall enhancement of your environment. It is preferable not

• to place the hot tub under an unguttered roof overhang since run-off water will shorten the life expectancy of the hot tub cover.

For spas that are to rest on balconies, roofs or other platforms not specifically tied into main structural support, consult a professional

Structural Engineer with experience in this type of application.

In the unlikely event that you should ever need to access or gain entry to any portion of the spa for servicing, it is highly recommended that you plan your outdoor installation to provide full access to the entire spa. Please take this into consideration when placing the spa in a deck or enclosed by a surrounding.

4.2 Indoor Location

For indoor installations many factors need to be considered before installing a spa indoors:

!

WARNING:

In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of contracting a waterborne illness (e.g. an infection, bac teria or virus) and/or respiratory ailments that could be pres ent in the air or water. Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.

PROPER FOUNdATION: Consult a Structural Engineer when considering a foundation that will adequately support the spa the entire time it is in place.

Proper support is critical especially if the spa is to rest on a second story or higher. For spas that are to rest on balconies, roofs or other platforms not specifically tied into the main structural support, you should consult a professional

Structural Engineer with experience in this type of application.

PROPER dRAINAGE: It is extremely important to have in place measures to sufficiently handle excessive water spillage.

Be sure the flooring in which the spa rests on has adequate drainage

Page 10

880 SERIES

and can handle draining of the entire contents of the spa. Be sure to make provisions for ceilings or any other structures that may be below the spas installation. Areas around your spa can become wet or moist so all flooring and subsequent furniture, walls and adjacent structures should be able to withstand or resist water and moisture.

PROPER VENTILATION: Proper ventilation should be discussed with an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and air associated with chemical odors outdoors.

When the spa is in use considerable amounts of moisture will escape potentially causing mold and mildew, over time this can damage certain surfaces and or surroundings.

• SUFFICIENT ACCESS:

In the unlikely event that you should ever need to access or gain entry to any portion of the spa for servicing, it is highly recommended that you plan your indoor installation to provide full access to the entire spa.

• WARRANTY:

Damage caused by not following these guidelines or any improper installation not in accordance with local codes or authorities is not covered under the spas warranty. Please consult your local state or city building ordinances.

5.0 General Electrical Safety Instructions

Your new Sundance

®

hot tub is equipped with the “state-ofthe-art” equipment system. It contains the most advanced safety and self-protective equipment in the industry.

Nonetheless, this hot tub must be installed properly to ensure dependable usage. Please contact your local

Sundance Spas dealer or local building department should you have any questions regarding your installation.

Proper grounding is extremely important. Sundance hot tubs are equipped with a current collector system. A pressure wire connector is provided on the surface of the control box, located inside the equipment

door (Figure C, page 1 4 ) to permit connection of a bonding wire between

this point and any ground metal equipment, metal water pipe or conduit within 5 feet (1.5m) of the hot tub, or copper clad grounding rod buried within 5 feet (1.5m) of the hot tub. Bonding wire must be at least No.

8 AWG (8.4 mm²) solid copper wire. This is a most important safety assurance feature.

Before installing your hot tub, check with your local government/electrical authority to ensure installation conforms to local country/area state codes.

Page 11

880 SERIES

6.0 Electrical Installation Instructions (240V Service)

IMPORTANT NOTICE:

The electrical wiring of this hot tub must meet the requirements of the National Electrical

Code (NEC) and any applicable state, local or country codes. The electrical circuit must be installed by a qualified electrician and approved by a local building/ electrical inspection authority in your state or country.

1.

!

dANGER:

TO dECREASE THE RISk OF SHOCk,

PROdUCT dAMAGE OR ELECTRICAL FIRE.

This hot tub must be permanently connected (hard-wired) to the power supply.

No plug-in connections or extension cords are to be used in conjunction with the operation of this hot tub.

Supplying power to the hot tub which is not in accordance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty.

2. The power supplied to this hot tub must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.

3. To determine the current, voltage and wire size required, refer to

Section 7.0 (

page 15

) for your specific hot tub model.

Wire size must be appropriate per NEC and/or local/country codes.

We recommend type THHN wire.

All wiring must be copper to ensure proper connections. Do not use aluminum wire.

When using wire larger than #6 (10 mm²), add a junction box near the hot tub and reduce to short lengths of #8 (8.4 mm²) wire to connect to the hot tub.

4. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422-20 of the National Electrical Code, ANSI/

NFPA 70. The disconnecting means must be readily accessible and visible to the hot tub’s occupant but installed at least 5 feet (1.5m) from the hot tub.

5. The electrical circuit supplied for the hot tub must include a suitable ground fault circuit interrupter (GFCI) as required by NEC Article

680-42.

6. To gain access to the hot tub’s power terminal block, remove the four screws securing the center cabinet panel (Maxxus™ and Aspen™ models only) or the Quick Release buttons (except Maxxus and Aspen models) on the side of the hot tub under the controls. Then remove the

four control box door screws and door (Figure C, page 1 4

).

Page 12

880 SERIES

7. Select the power supply entrance you want to use (Figures A-B,

pages 1 3-

1 4 ) and remove the short cabinet panel from the front of

the hot tub, then feed cable through the large opening provided on the bottom of the control box.

8. Connect wires, color to color, on terminal blocks TB1 and TB3

(Figure D). TIGHTEN SECURELY! All wires must be hooked up securely or damage could result.

9. Install c ontrol box door and reinstall the cabinet side panels.

Figure A (Maxxus/Aspen Equipment Area)

13

SPA CONTROLLER

12

1

7

2

9

11

3

4

5

14

10

9

Note:

Equipment location (such as pumps, CLEARRAY™ system, drain, heater etc.) varies by model.

1. Control Box

2. Power Supply Entrance(s)

3. Jets Pump

4. Jets Pump

5. Jets Pump

6. Blower

7. Heater

8. Hot Tub Drain (Removable

External Drain Cap)

6

2

8

9. Pump Drain Plug(s)

10. Filter/Circulation Pump

11. CLEARRAY™ (Ultraviolet) Water

Purification System

12. Electronic Ballast (for the

CLEARRAY System)

13. Control Panel

14. Quick Drain

Page 13

880 SERIES

Figure B (Equipment Area for All Models Except Maxxus/Aspen)

12

SPA CONTROLLER

1

4

11

2

6

8

10

9

3

2

5

13

7

Note:

Equipment location (such as pumps, CLEARRAY™ system, drain, heater etc.) varies by model.

1. Control Box

2. Power Supply Entrance(s)

3. Jets Pump

4. Heater

5. Hot Tub Drain (Removable External Drain Cap)

6. Air Blower

7. Pump Drain Plug(s)

8. Jets Pump

9. Filter/Circulation Pump

10. CLEARRAY

(Ultravoilet)

Purification System

11. Electronic Ballast (for CLEARRAY

System)

12. Control Panel

13. Quick Drain

Figure C

Control Box

Figure d

Terminal Block 240V

Wire Connection

60 Hz

TB1

Red (L2)

Green

Black (L1)

TB3

1. Terminal Block

2. Bonding Lug

3. Grounding Terminal

50 Hz

(refer to pages 81 and 82

for wiring diagram)

TB2 TB1

Blue (N)

Ground

Brown (L)

TB3

Page 14

880 SERIES

7.0 Power Requirements

Sundance

®

hot tubs are designed to provide optimum performance and flexibility of use when connected to their maximum electrical service. However, they are shipped factory configured for their most common preferred electrical connection.

If you prefer, a qualified technician can perform a minor circuit board modification that allows the hot tub to operate on a different electrical service (see table below).

7.1 North American 60 Hz Power Options

Voltage

Max. Current Draw

Number of Wires

North American 60 Hz Maxxus/

Aspen

Circuit Breaker (2-Pole)

240V/50A*

240 VAC

38A

3

50A*

240V/60A**

240 VAC

48A

3

60A**

*

In this configuration, the heater

will not operate

while any two jets pumps are running.

**

In this configuration the heater

will operate while

any two jets pumps and the blower are running but

will not operate

when all three jets pumps are running.

This is the factory default setting.

North American 60 Hz Altamar/Cameo/Majesta/Marin/Optima

Voltage

Max. Current Draw

Number of Wires

Circuit Breaker (2-Pole)

240V/40A*

240 VAC

26A

3

40A*

240V/50A**

240 VAC

40A

3

50A**

240V/60A***

240 VAC

48A

3

60A***

*

In this configuration, the heater

will not operate

while either jets pump is running or when the blower is running.

**

In this configuration, the heater

will not operate

while both jet pumps are running.

This is the factory default setting.

***

In this configuration the heater

will operate while

both jets pumps and the blower are running.

Page 15

880 SERIES

Voltage

Max. Current Draw

Number of Wires

North American 60 Hz Capri

240V/40A*

240 VAC

26A

3

240V/50A**

240 VAC

40A

3

Circuit Breaker (2-Pole) 40A* 50A**

*

In this configuration, the heater

will not operate

while the jets pump is running or when the blower is running.

**

In this configuration, the heater

will operate

while the jets pump and blower are running.

This is the factory default setting.

7.2 Export 50 Hz Power Options

Voltage

Frequency

Max. Current Draw

Wattage

Export 50 Hz Maxxus/

Aspen

230V26A*

230 VAC

230V/34A**

230 VAC

50 Hz

34A

8,05 kW

230V/42A***

230 VAC

50 Hz 50 Hz

26A

5,98 kW

42A

9,89 kW

Number of Wires 3 3 3

*

In this configuration, the heater

will not operate

while either jets pump is running or when the blower is running.

**

In this configuration, the heater

will not operate

while any two jets pumps are running.

***

In this configuration the heater

will operate while

any two jets pumps and the blower are running but

will not operate

when all three jets pumps are running.

This is the factory default setting.

Export 50 Hz Altamar/Cameo/Majesta/Marin/Optima

Voltage

Frequency

230V/16,6A

230 VAC

50 Hz

230V/31,6A

230 VAC

50 Hz

Max. Current Draw

Wattage

16,6 Amps*

3,8 kW

31,6 Amps**

7,3 kW

Number of Wires 3 3

*

Standard 16,6 Amp (3,8 kW) configuration. The heater

will not operate

while both jets pump are running.

**

Alternate 31,6 Amp (7,3 kW) configuration, the heater

will operate

while jets pumps are running.

Page 16

880 SERIES

Export 50 Hz Capri

Voltage

Frequency

Max. Current Draw

230V/12,1A

230 VAC

50 Hz

12,1 Amps*

230V/23,6A

230 VAC

50 Hz

23,6 Amps**

Wattage

Number of Wires

2,8 kW

3

5,4 kW

3

*

Standard 12,1 Amp (2,8 kW) configuration. The heater

will not operate

while the jets pump is running.

**

Alternate 23,6 Amp (5,4 kW) configuration. The heater

will operate

while the jets pump is running.

8.0 Hot Tub Fill Up Procedure

For best results, read each step in its entirety before proceeding with that step.

1.

Prepare The Hot Tub For Filling

• Clear all debris from the hot tub. (Although the hot tub shell has

• been polished at the factory, you may want to treat it with a specially formulated hot tub cleaner.) Consult your dealer for additional information prior to filling hot tub.

Remove filter lid (Sections 9.4-9.25, pages 2 5 -4 6 ), then remove filter cartridge from filter bucket as illustrated in Section 13.1.

2.

Fill Hot Tub

• Place the end of your garden hose into the empty filter bucket.

CAUTION: TO dECREASE BUILd UP ON COMPONENTS ANd

MINIMIZE ACRYLIC dAMAGE.

Never fill with water from a water softener. If your water is extremely

“hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. Water that is too soft can be corrosive to metal components.

!

WARNING:

dISEASE.

TO dECREASE RISk OF INFECTION OR

Fill hot tub with clean tap water from garden hose, to reduce risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments . Fill until water covers all jets but does not touch the bottom of the lowest headrest. (DO NOT OVERFILL!)

Page 17

880 SERIES

IMPORTANT:

Always fill your hot tub through the filter bucket after draining. Failure to do so may cause air to be trapped in either pump, preventing the pump from circulating water. Remove the hose and replace the filter cartridge as illustrated in Section 13.1.

3.

Turn On Power

Turn on power to hot tub at the home’s circuit breaker to start boot up sequence . The heater and filter/circulation pump will automatically activate. If the control panel LCD flashes water temperature and

“COOL” or “ICE”, this is normal.

4.

Activate jets Pumps

Turn on all jet(s) pumps and blower to ensure proper mixing when adding start up chemical in step 5.

5.

Add Start-Up Chemicals

Add the hot tub water chemicals as recommended by your Sundance

Spas dealer. See Section titled “Water Quality Maintenance” ( page

69) for general guidance.

!

WARNING:

RISk OF POISONING OR dEATH.

Never leave chemicals opened and accessible to anyone.

Use chemicals according to the vendors instructions. Always store chemicals in a safe and/or locked location. Keep away from and out of reach of children.

6.

Establish A Stable Sanitizer Reading

Establish a stable sanitizer reading no less than 1.0 ppm free chlorine or 2.0 ppm bromine. To ensure healthy water conditions, always maintain a constant sanitizer reading within the levels recommended on the inside cover of this manual. If sanitizer levels cannot be stabilized, perform the decontamination procedure steps 9-15 on the following page.

Note:

The “decontamination procedure” steps 9-15 should also be used after the hot tub has been “Winterized” (Section 13.9) or has been sitting without power for an extended period.

7.

Set Hot Tub To Heat

To warm hot tub water to a comfortable temperature, follow

• these steps:

The LCD display on the control panel displays the actual temperature of the hot tub water. Press either the

COOLER

(Down) or

WARMER

(Up) button once to display the “set” temperature for

5 seconds. If you want the water to heat to a different temperature, simply press

COOLER

or

WARMER

within 5 seconds. The set

Page 18

880 SERIES

temperature increases or decreases by one degree each time either button is pressed.

The heater will turn off when the temperature corresponding to the thermostat setting is achieved.

Important Heater details:

• The maximum temperature for which the hot tub can be set is

104°F (40°C) and the minimum is 80°F (27°C).

• For Cameo and Optima hot tubs powered with a 40 amp service, turn off jets pump #1 and jets pump #2 to operate heater.

• Setting the thermostat at maximum will not accelerate the heating process. This will only result in a higher ultimate temperature.

• The heater operates until the water reaches the programmed “set temperature”, then turns off. The heater will reactivate after the water cools to approximately 1° below the “set temperature.”

8.

Place Cover On Hot Tub

• Keeping the insulating cover in place anytime the hot tub is not in

• use will reduce the time required for heating, thereby minimizing operating costs.

The time required for initial heat-up will vary depending on the starting water temperature.

!

dANGER:

RISk OF PERSONAL INjURY.

Check water temperature carefully before entering hot tub! Excessive water temperature can cause burns, welts and body temperature to rise, hyperthermia (overheating).

decontamination Procedure (Steps 9-15)

Steps 9-15 below are only required when sanitizer levels are unstable after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer levels remain stable after performing steps 1-6 above (refer to the inside cover of the manual).

9 . Add 2.5 ounces of sodium dichlor for every 100 gallons of water. Refer to the table (below) for approximate water fill capacity by model.

!

CAUTION: RISk OF PERSONAL INjURY OR SPA dAMAGE!

Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemicals may damage components within your hot tub, burn or irritate your skin, create a rash, and void the manufacturer warranty for your spa.

Page 19

880 SERIES

Water Fill Volume

Model

Average

Fill Volume*

Sodium dichlor

Altamar ...............................

395 Gal (1,495 L) .............................

10.0 oz

Aspen .................................

XXX Gal (X,XXX L) ..........................XX.X oz

Cameo ................................

370 Gal (1,401 L) .............................

9.0 oz

Capri ...................................

260 Gal (984 L) ................................

7.0 oz

Majesta ...............................

330 Gal (1,249 L) .............................

8.0 oz

Marin...................................

320 Gal (1,211 L) ..............................

8.0 oz

Optima ................................

420 Gal (1,590 L) ............................

10.5 oz

Maxxus ...............................

550 Gal (2,082 L) .............................

14.0 oz

*Use average fill volume for chemical maintenance

1 0. Leave hot tub cover open during this step to allow excessive chemical vapors to exit hot tub, protecting pillows and plastic knobs from chemical attack. If hot tub is indoors, open doors and windows for proper ventilation. Turn on all hot tub jets pumps for one hour, open all air controls, turn on the blower, and place all massage selector knob(s) in their center “combo” position as shown (right).

Note:

You will need to press the jets pump button(s) and blower button every 20 minutes since these functions have an automatic 20 minute time-out function that turns them off.

!

WARNING:

RISk OF PERSONAL INjURY!

To decrease the risk of injury, drowning or entrapment, never leave your hot tub unattended for any reason while the cover is open and accessible, especially to small children and animals!

Precautions should be taken to minimize your exposure to chemical vapors (that could cause lung, brain, or skin damage).

11. Turn off power to the hot tub at the circuit breaker, then drain tub as outlined in Section 13.3

(page 6 4 ).

12. Refill hot tub with clean tap water from garden hose until water covers all jets but does not touch the bottom of the lowest headrest.

(DO NOT OVERFILL!)

CAUTION: TO dECREASE BUILd UP ON COMPONENTS ANd

MINIMIZE ACRYLIC dAMAGE.

Never fill with water from a water softener. If your water is extremely

“hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. Water that is too soft can be corrosive to metal components.

Page 20

880 SERIES

13. Consult your authorized Sundance Spas dealer for chemical recom mendations, then add chemicals to hot tub water to achieve a con stant sanitizer reading within the levels recommended on the inside cover of this manual.

14. Turn on all jet pumps and the blower when adding chemicals to ensure proper mixing and leave your hot tub cover open until the sanitizer level becomes stable to protect pillows and plastic knobs from chemical attack. Refer to the inside cover of the manual.

!

WARNING:

RISk OF PERSONAL INjURY.

To decrease the risk of injury, entrapment or drowning, never leave your hot tub unattended for any reason, es pecially if while the cover is open and accessible to small children and animals!

To decrease the risk of contracting a waterborne illness

(e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water chemistry within 6 step param eters. If you or other bathers experience such a condition, discontinue use and seek immediate medical attention.

15. Establish a sanitizer reading no less than 1.0 ppm free chlorine or

2.0 ppm bromine , then allow the hot tub to set undisturbed for 8 hours. Retest water after 8 hours to determine if sanitizer levels are stable. If sanitizer levels are stable, your hot tub is ready for use.

To ensure healthy water conditions, always maintain a constant sanitizer reading within the levels recommended on the inside cover of this manual. If sanitizer levels are not stable at this time, it will be necessary to repeat this procedure in its entirety (steps 1-15) until stable sanitizer readings are achieved.

IMPORTANT:

If the CLEARRAY™ water purification system is removed from the hot tub or is not operating efficiently follow the “without

CLEARRAY™” water chemistry parameters. Such parameters are defined by the Association of Pool and Spa Professionals.

16. After adequate sanitizer levels are achieved, close all spa air controls by rotating them clockwise to maximize heat retention when spa is not in use.

Page 21

880 SERIES

9.0 Hot Tub Features

9.1 Main Control Panel Functions (except Capri Models)

A.

Select Button:

Scrolls menu through filter cycle programming features.

Manually activates the circulation pump when it is in an off state for a 1 hour duration.

K

J I H G F E

A

2 or 3 Pump Spa Control Panel

B

C

D

B.

Cycle Button:

Accesses filter cycle program mode and advances display to next cycle.

C.

Mode Button:

Switches between Standard and Economy modes.

D.

display Button:

Displays time of day and initiates time setting and locking functions.

E.

Invert Button:

Inverts the main 4-digit LCD display.

F.

jets 2 Button:

Controls jets pump #2 (and Maxxus/Aspen Jets pump #3).

G.

jets 1 Button:

Controls jets pump #1.

H.

Blower Button:

Controls air blower.

I.

Light Mode Button:

Selects one of 4 color modes for waterfall, footwell and air control lights.

J.

Light Button:

Turns waterfall, footwell air control lights on in unison.

Press once for high intensity; press a second time for medium intensity; press a third time for low intensity; press a fourth time to turn off. The displayed color is changed using the light mode button.

K.

Warmer ( ) and Cooler ( ) Buttons:

These buttons display and increase or decrease temperature setting and other programming features.

Page 22

880 SERIES

9.2 Main Control Panel Functions (Capri Models Only)

I I

A.

Select Button:

Scrolls menu through filter cycle programming features. Manually activates the circulation pump when it is in an off state for a 1 hour duration.

B.

Cycle Button:

Accesses filter cycle program mode and advances display to next cycle.

C.

Mode Button:

Switches between Standard and Economy modes.

D.

display Button:

Displays time of day and initiates time setting and locking functions.

E.

jets 1 Button:

Controls jets pump #1.

F.

Blower Button:

Controls air blower.

G.

Light Button:

Controls hot tub footwell and waterfall light.

H.

Invert Button:

Inverts the main 4-digit LCD display.

I.

Warmer ( ) and Cooler ( ) Buttons:

These buttons display and increase or decrease temperature setting and other programming features.

Page 23

880 SERIES

9.3 LCd Screen Functions

= Lock: Indicates panel, set temperature, or filter cycle programming is locked.

= Heat: Indicates heater is on.

AM

PM

STANDARD

= Sanitizer: Indicates that the sanitizing system is on (page 7 0

).

The Electronic Ballast (page 1 3

) solid red light indicates that the CLEARRAY™ System is activated. A solid green light indicates that the system is being provided power.

= Adjust Filter Cycle: Indicates filter cycle programming feature is accessed.

= Filter Cycle Number: Indicates which programmed filter cycle is running.

= Filter Cycle: Indicates programmed filter cycle is running.

= Filter Cycle Start Time: Indicates filter cycle start time programming is accessed.

= Filter Cycle Duration: Indicates filter cycle duration programming is accessed.

= Set Temperature: Indicates current set temperature is displayed.

= Set Time: Indicates current time is displayed.

= Filter Annunciator: Indicates filter cleaning and/or replacement is required.

= Blower: Indicates blower is on.

= Jets 1: Indicates jets pump 1 is on.

= Jets 2: Indicates jets pump 2 is on (also shown for Maxxus/

Aspen Pump 3).

STANDARD

= Mode: Indicates selected filter mode.

Note:

No icon means Economy mode is selected.

Page 24

880 SERIES

9.4 Maxxus Hot Tub Features

7

22

19

4

5

22

7

25

7

10

8

11

18

13

20

11

13

20

13

13

12

24

27

24

27

3

17

13 13

13

13

27

27

12

10

19

20

13

13

12

12

7

11

20

22

26

26

5

26

4

22

14

11

7

15

16

25

25

7

20

20

25

12

9

11

8

23

7

7

24

5

6

3

11

24

24

5

22

2 2

4

4

1

22

21

1. Main Control Panel

2. Handrails with LED Light (2 ea.)

3. Lights (2 ea.)

4. Pillows (4 ea.)

5. Fluidix Nex Jets (8 ea.)

6. Fluidix Intelli-Jets (2 ea.)

7. Air Controls with LED Light (8 ea.)

8. Whirlpool Jets (2 ea.)

9. Gravity Drain

10. Massage Selectors (2 ea.)

11. Air Injectors (6 ea.)

12. Suction Covers (6 ea.; one is not shown)

13. Accu-Pressure Jets (14 ea.)

14. Weir Gate/Skimmer

15. Filter Lid (The filter cartridge and suction fitting/filter are located under the filter lid. The suction fitting filter requires periodic cleaning for optimum perfor mance)

16. AquaTerrace Waterfall Control Valve

17. AquaTerrace Waterfall Filtration

Return

18. Fluidix ST Jets (12 ea.)

19. AquaTerrace Waterfalls (2 ea.)

20. Pulsator Jets (6 ea.)

21. Optional Audio System Receiver

22. Optional Audio System Speakers

(6 ea.)

23. Sunscents™ Dispenser

24. Vortex Jets (7 ea.)

25. Integrated cupholders (4 ea.)

26. Fluidix Reflex Jets (6 ea.)

27. Focus-Relief Jets (8 ea.)

Spa features subject to change without notice.

Page 25

880 SERIES

9.5 Maxxus Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selectors 1 and 2 to divert water between designated jet groups.

3

2 a b

2b

2a

2b

2a

2b

2a

2b

4

4

4

4

3

4

1 a b

1b

1b

1b

2b

1b

1a

Massage Selectors (1-2)

• Massage Selector #1 controls pump #1.

• Massage Selector #2 controls pump #2.

Waterfall Selector (3)

• Waterfall Selector #3 controls waterfall output.

Continuously Powered jets (4)

• Jets #4 are always on when jets pump #3 is running.

Spa operation subject to change without notice.

Page 26

880 SERIES

9.6 Maxxus Air Controls diagram

Air Control Operation

Rotate Air Controls 1-8 to add air to designated jet groups.

Turn the Blower on to add air to jets group 9.

4 5

3

2

4

3

2

4

2

4

2

4

1

9

5

6

6

6

6

1

1 1

1

8

7

6

7

8

Spa operation subject to change without notice.

Page 27

880 SERIES

9.7 Aspen Hot Tub Features

To Be Announced

Page 28

Spa features subject to change without notice.

9.8 Aspen Massage/Waterfall Selector diagram

880 SERIES

To Be Announced

Spa operation subject to change without notice.

Page 29

880 SERIES

9.9 Aspen Air Controls diagram

To Be Announced

Page 30

Spa operation subject to change without notice.

880 SERIES

9.10 Optima Hot Tub Features

21

7

24

4

5

8

19

21

18

11

18

13

25

7

10

11

11

13

13

25

17

12

23

13 13

23

12

13

13

7

22

11

11

9

11

11

3

16

11

12

7

11

11

14

21

18

5

6

15

18

4

21

10

24

11

11

24

7

21

6

11

11

23

23

4

4

2 2

21

20

1. Main Control Panel

2. Handrails with LED Light (2 ea.)

3. Light

4. Pillows (4 ea.)

5. Fluidix Nex (4 ea.)

6. Fluidix Intelli-Jets (5 ea.)

7. Air Controls with LED Light (5 ea.)

8. Whirlpool Jets (1 ea.)

9. Gravity Drain

10. Massage Selectors (2 ea.)

11. Air Injectors (14 ea.)

12. Suction Covers (4 ea.; one is not shown )

13. Accu-Pressure Jets (12 ea.)

14. Weir Gate/Skimmer

15. Filter Lid (The filter cartridge and suction fitting/filter are located under the filter lid.

The suction fitting filter requires periodic

1

cleaning for optimum performance)

16. AquaTerrace Waterfall Control Valve

17. AquaTerrace Waterfall Filtration Return

18. Fluidix ST Jets (16 ea.)

19. AquaTerrace Waterfall

20. Optional Audio System Receiver

21. Optional Audio System Speakers

(6 ea.)

22. Sunscents Dispenser

23. Vortex Jets (7 ea.)

24. Integrated Cupholders (3 ea.)

25. Pulsator Jets (2 ea.)

Spa features subject to change without notice.

Page 31

880 SERIES

9.11 Optima Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selectors 1 and 2 to divert water between designated jet groups.

3

3

2a

1b

5

2a

2b

1a

2 a b

5

2a

5 b a

1

4

2b

1b

1a

Massage Selectors (1-2)

• Massage Selector #1 controls pump #1.

• Massage Selector #2 controls pump #2.

Waterfall Selector (3)

• Waterfall Selector #3 controls waterfall output.

Continuously Powered jets (4-5)

• Jets #4 are always on when jets pump #1 is running.

• Jets #5 are always on when jets pump #2 is running.

Spa operation subject to change without notice.

Page 32

880 SERIES

9.12 Optima Air Controls diagram

Air Control Operation

Rotate Air Controls 1-5 to add air to designated jet groups.

4

2

1

2

3

3

3

1

3

3

5

5

1

1

4

4

5

Spa operation subject to change without notice.

Page 33

880 SERIES

9.13 Cameo Hot Tub Features

16 7 25

19

24

13

21

14

23 27 27

26

26

5

4

15

23

27 27

17

8

8

24

9

13

11

21

7

8

23

12

12

22

10

7

25

11

24

13

24

18

21

5

18

11

4

2

21

7

20

1. Control Panel

2. Handrails with LED Light (2 ea.)

3. Light

4. Pillows (3 ea.)

5. Fluidix Nex Jets (6 ea.)

6. Fluidix Intelli-Jets (2 ea.)

7. Air Controls with LED Light (5 ea.)

8. Whirlpool Jets (4 ea.)

9. Gravity Drain

10. Massage Selectors (2 ea.)

11. Air Injectors (6 ea.)

12. Suction Covers (6 ea.; one is not shown)

13. Accu-Pressure Jets (6 ea.)

14. Weir Gate/Skimmer

15. Filter Lid (The filter cartridge and suction fitting/filter are located under the filter lid.

The suction fitting filter requires periodic

1

12

3

13

2

11

Spa features subject to change without notice.

11

11

6

21

23

5

4

21

cleaning for optimum performance)

16. AquaTerrace Waterfall Control Valve

17. AquaTerrace Waterfall Filtration

Return

18. Fluidix ST Jets (12 ea.)

19. AquaTerrace Waterfall

20. Optional Audio System Receiver

21. Optional Audio System Speakers (6 ea.)

22. Sunscents Dispenser

23. Vortex Jets (6 ea.)

24. Pulsator Jets (4 ea.)

25. Integrated Cupholders (3 ea.)

26. Fluidix Reflex Jets (6 ea.)

27. Focus-Relief Jets (8 ea.)

25

10

7

Page 34

880 SERIES

9.14 Cameo Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selectors 1 and 2 to divert water between designated jet groups.

3

3

2a

2a

2a

2a

2a

2a

2a

1a

2b

1b

1 a b

1b

1b

1b

1b

2b a b

2

2b

Massage Selectors (1-2)

• Massage Selector #1 controls pump #1.

• Massage Selector #2 controls pump #2.

Waterfall Selector (3)

• Waterfall Selector #3 controls waterfall output.

Spa operation subject to change without notice.

Page 35

880 SERIES

9.15 Cameo Air Controls diagram

Air Control Operation

Rotate Air Controls 1-5 to add air to designated jet groups.

Turn the Blower on to add air to jets group 6.

3

4

6

4

4

4

4

4

4

3

2

2

1

5

1

1

1

1

4

4

5

4

1

5

Page 36

Spa operation subject to change without notice.

880 SERIES

9.16 Altamar Hot Tub Features

21

24 7

16

19

4

5

23

8

21

11

6

7

7

24

21

5

11

18

4

21

7

11

11

12

17

10

11

12

12

6

2

22

4

21

25

11 11

13

26

26

9

8

3

26

26

13

26

26

11

6

14

6

15

21

7

1

20

1. Main Control Panel

2. Handrail with LED Light

3. Light

4. Pillows (3 ea.)

5. Fluidix Nex (4 ea.)

6. Fluidix Intelli-Jets (6 ea.)

7. Air Controls with LED Light (5 ea.)

8. Whirlpool Jets (3 ea.)

9. Gravity Drain

10. Massage Selectors

11. Air Injectors (8 ea.)

12. Suction Covers (4 ea.; one is not shown )

13. Pulsator Jets (2 ea.)

14. Weir Gate/Skimmer

15. Filter Lid (The filter cartridge and suction fitting/filter are located under the filter

Spa features subject to change without notice.

lid. The suction fitting filter requires periodic cleaning for optimum perfor mance)

16. AquaTerrace Waterfall Control Valve

17. AquaTerrace Waterfall Filtration Return

18. Fluidix ST Jets (12 ea.)

19. AquaTerrace Waterfall

20. Optional Audio System Receiver

21. Optional Audio System Speakers

(6 ea.)

22. Sunscents Dispenser

23. Vortex Jets (2 ea.)

24. Integrated Cupholders (2 ea.)

25. Fluidix Reflex (6 ea.)

26. Focus-Relief Jets (6 ea.)

Page 37

880 SERIES

9.17 Altamar Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selector 1 to divert water between designated jet groups.

2

2

1a

3

1b a b

1

1a

1b

3

3 3

Massage Selectors (1)

• Massage Selector #1 controls pump #2.

Waterfall Selector (2)

• Waterfall Selector #2 controls waterfall output.

Continuously Powered jets (3)

• Jets #3 are always on when jets pump #1 is running.

Spa operation subject to change without notice.

Page 38

880 SERIES

9.18 Altamar Air Controls diagram

Air Control Operation

Rotate Air Controls 1-5 to add air to designated jet groups.

Turn the Blower on to add air to jets group 6.

3

4

5

2

3

4

5

2

2

3

1

1

6

1

1

1

Spa operation subject to change without notice.

Page 39

880 SERIES

9.19 Majesta Hot Tub Features

7

21

7

19

4

5

21

18

11

23

10

6

11

11

11

12

9

17

12

16

24

11

12

11

11

11

6

21

5

23

4

21

11

7

7

13

11

13

7

22

11

11

11

8

3

8

21 6

5 11

4

21

2

20

1. Main Control Panel

2. Handrail with LED Light

3. Light

4. Pillows (3 ea.)

5. Fluidix Nex (6 ea.)

6. Fluidix Intelli-Jets (6 ea.)

7. Air Controls with LED Light (5 ea.)

8. Whirlpool Jets (2 ea.)

9. Gravity Drain

10. Massage Selector (1 ea.)

11. Air Injectors (14 ea.)

12. Suction Covers (4 ea.; one is not shown )

13. Accu-Pressure Jets (2 ea.)

14. Weir Gate/Skimmer

15. Filter Lid (The filter cartridge and suction

1

14

15

fitting/filter are located under the filter lid. The suction fitting filter requires periodic cleaning for optimum perfor mance)

16. AquaTerrace Waterfall Control Valve

(6 ea.)

22. Sunscents Dispenser

23. Vortex Jets (3 ea.)

24. Integrated Cupholders (1 ea.)

Spa features subject to change without notice.

-

17. AquaTerrace Waterfall Filtration Return

18. Fluidix ST Jets (12 ea.)

19. AquaTerrace Waterfall

20. Optional Audio System Receiver

21. Optional Audio System Speakers

Page 40

880 SERIES

9.20 Majesta Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selector 1 to divert water between designated jet groups.

2

2

1a

3

3 a

1 b

3

3

1b

3

Massage Selectors (1)

• Massage Selector #1 controls pump #2.

Waterfall Selector (2)

• Waterfall Selector #2 controls waterfall output.

Continuously Powered jets (3)

• Jets #3 are always on when jets pump #1 is running.

Spa operation subject to change without notice.

Page 41

880 SERIES

9.21 Majesta Air Controls diagram

Air Control Operation

Rotate Air Controls 1-5 to add air to designated jet groups.

2

3

2

3

1

4

4

5

1

4

4

1

5

1

1

Page 42

9.22 Marin Hot Tub Features

21 7

24

7

10

21

5

4

5

18

11

11

12

11

19

3

16

7

11

6

21

12

17

11

11

23

6

4

880 SERIES

21

24

23 6 11

6

14

15

4

13

11

12

9

25

21

22

11

26

4 8 8

6

11

26

25

21

2

7

20

1

1. Main Control Panel

2. Integrated Handrail

3. Light

4. Pillows (4 ea.)

5. Fluidix Nex (2 ea.)

6. Fluidix Intelli-Jets (7 ea.)

7. Air Controls with LED Light (4 ea.)

8. Fluidix Reflex Jets (6 ea.)

9. Gravity Drain

10. Massage Selector (1 ea.)

11. Air Injectors (10 ea.)

12. Suction Covers (4 ea.; one is not shown )

13. Accu-Pressure Jets (2 ea.)

14. Weir Gate/Skimmer

15. Filter Lid (The filter cartridge and suction fitting/filter are located under the filter lid.

The suction fitting filter requires periodic cleaning for optimum performance)

16. AquaTerrace Waterfall Control Valve

17. AquaTerrace Waterfall Filtration Return

18. Fluidix ST Jets (10 ea.)

19. AquaTerrace Waterfall

20. Optional Audio System Receiver

21. Optional Audio System Speakers

(6 ea.)

22. Sunscents Dispenser

23. Vortex Jets (2 ea.)

24. Integrated Cupholders (2 ea.)

25. Pulsator Jets (2 ea.)

26. Focus-Relief (2 ea.)

Spa features subject to change without notice.

Page 43

880 SERIES

9.23 Marin Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selector 1 to divert water between designated jet groups.

2

2

3

1a

1 a b

3

3

1b

3

1b

1b

1b

1b

Massage Selectors (1)

• Massage Selector #1 controls pump #2.

Waterfall Selector (2)

• Waterfall Selector #2 controls waterfall output.

Continuously Powered jets (3)

• Jets #3 are always on when jets pump #1 is running.

Spa operation subject to change without notice.

Page 44

880 SERIES

9.24 Marin Air Controls diagram

Air Control Operation

Rotate Air Controls 1-4 to add air to designated jet groups.

Turn the Blower on to add air to jets group 5.

3 4

4

3

2

2

2

1

2

1

5 1

1

1

Spa operation subject to change without notice.

Page 45

880 SERIES

9.25 Capri Hot Tub Features

7

8

18

7

10

4

4 5

6

11

11

11

14

13 13

7

11

14

9

1

23 23

2

11

20

11

11

11

12

23 23

19

3

15

22

11

15

16

4

11

15

17

21

1. Control Panel

2. Integral Handrail

3. Gravity Drain

4. Pillows (3 ea.)

5. Fluidix Nex Jets (2 ea.)

6. Fluidix ST Jets (10 ea.)

7. Air Controls (3 ea.)

8. Waterfall Control Valve (1 ea.)

9. Light

10. Massage Selectors (1 ea.)

11. Air Injectors (10 ea.)

12. Waterfall Bypass Fitting

13. Fluidix Reflex Jets (6 ea.)

14. Pulsator Jets (2 ea.)

15. Fluidix Intelli-Jets (3 ea.)

16. Vortex Jet (1 ea.)

17. Filter Lid (The filter cartridge and suction fitting/filter are located under the filter lid. The suction fitting requires periodic cleaning for optimum performance)

18. AquaTerrace Waterfall

19. SunScents Dispenser

20. Footwell Suction Cover (2 ea. one is not shown)

21. AquaTerrace Light Control Panel

22. Weir Gate/Skimmer

23. Focus-Relief Jets (4 ea.)

Spa features subject to change without notice.

Page 46

880 SERIES

9.26 Capri Massage/Waterfall Selector diagram

Massage Selector Operation

Rotate Massage Selector 1 to divert water between designated jet groups.

2

2

1b

1a

1 b a

1b

1b

1b

1b

1b

Massage Selectors (1)

• Massage Selector #1 controls pump #1.

Waterfall Selector (2)

• Waterfall Selector #2 controls waterfall output.

Spa operation subject to change without notice.

Page 47

880 SERIES

9.27 Capri Air Controls diagram

Air Control Operation

Rotate Air Controls 1-3 to add air to designated jet groups.

Turn the Blower on to add air to jets group 4.

2 3

3

2

1

1

1

4 1

1

Page 48

Spa operation subject to change without notice.

880 SERIES

10.0 Operating Instructions

Your Sundance® hot tub has a touch-sensitive control panel, massage selector valves and air control knobs located on the top rim of the hot tub

(Sections 9.4-9.27, pages 2 5

-4 8). These controls let you operate many of

the special functions of your Sundance® hot tub. By familiarizing yourself with the following information, you will be able to gain the full benefit afforded by the various functions of your hot tub.

Note:

Button appearance varies for the Capri Model.

10.1 View Button

Pressing this button inverts the main four-digit display on the

Command Center’s LCD screen to allow easy reading from either inside or outside the hot tub.

10.2 Air Injection

When the

AIR

button is pressed, the air blower forces air through the injectors and Focus-Relief Jets. The bubbles symbol on the button appears on the LCD whenever the air blower is on. An electronic timer automatically turns the air blower off 20 minutes after it was turned on.

Note:

The air blower automatically activates for 1 minute at the start of the clean-up cycle at 12:00 (Noon). This clears the lines of the air injector system to help ensure that all water is exposed to sanitizer. This cycle is non-programmable.

10.3 Controlling the water temperature

Press either the

COOLER

( ) or

WARMER

( ) button once to display the “set” temperature for 5 seconds. If you want the water to heat to a different temperature, simply press

COOLER

or

WARMER

within 5 seconds.

The set temperature increases or decreases by one degree each time either button is pressed.

A

B

To access the overtemp feature that allows the spa to reach 106°F (41°C) proceed with the following

C

steps (Figure 1). Reference Section 3.0, page 2 for important safety

instructions.

Figure 1

!

WARNING:

RISk OF HYPERTHERMIA (OVER-HEATING)

CAUSING SEVERE INjURY, BURNS, WELTS OR dEATH!

Water temperature in excess of 104°F (40°C) may be injurious to your health.

Page 49

880 SERIES

A. Press and hold the

WARMER

(

B. Press and hold the

jETS 1

(

) button then;

) button at the same time for 2 seconds. You will see the temperature rise to 106°F (41°C) on the LCD display. To lower the temperature, press the

COOLER

( ) button.

C. When the overtemp has been activated, the white decimal point after the last digit will flash on and off every second as an indicator for being in the overtemp mode.

Note:

Once the temperature goes below 104°F (40°C) and you would like to raise the temperature to 106°F (41°C) again, you will have to repeat the steps above.

10.4 Activate jets Pump 1

This button controls jets pump #1. Press once to turn on jets pump #1. Press a second time to turn pump off.

10.5 Activate jets Pump 2/Pump 3

On two pump models, this button controls jets pump #2. Press once to turn on jets pump #2. Press a second time to turn pump off.

On three pump Maxxus/Aspen models, this button controls both jets pump #2 and jets pump #3 in the following sequence:

1. Press once to turn on jets pump #2.

2. Press a second time to turn on jets pump #3.

3. Press a third time to turn off jets pump #2.

4. Press a fourth time to turn off jets pump #3.

Note:

Anytime a jet pump has been manually activated, it will automatically turn off after approximately 20 minutes. If at this time you desire more jet operation you may simply turn the pump(s) back on.

10.6 Light Button (Except Capri Model)

Pressing this button activates the footwell, waterfall and air control LED lights in sequence as follows: High - Medium - Low - Off.

Note:

Lights automatically turn off after 2 hours.

Waterfall(s)

Anytime the light system has been manually activated, it will automatically turn off after approximately 2 hours. If at this time you desire more light operation, simply turn the light system back on.

Air Control(s)

Footwell

This button offers four light modes for your enjoyment. Press the LIGHT MODE button to select our favorite lighting effect as follows:

Page 50

880 SERIES

Press

Once

High-Speed Color Blend Mode

Press

Again

Low-Speed Color Blend Mode

Press

Again

Freeze Color Blend Mode:

Selects or “freezes” your low speed blending color of choice.

Press

Again

BLUE (X4) VIOLET (X5) RED (X6) AMBER (X7) GREEN (X8) AQUA (X9)

NEAR

WHITE (X10)

Solid Color Mode:

Selects one of 7 solid (high-intensity) colors of choice.

10.7 Light Button (Main Control Panel; Capri Model Only)

Pressing the LIGHT button activates both footwell and waterfall lights in random color mode. Upon startup, both lights quickly advance through all seven colors, then change colors every 4 seconds thereafter. At this time, you can choose one of seven constant colors on the AquaTerrace control panel.

Pressing this button a second time turns both lights off.

Waterfall(s)

Footwell

10.8 AquaTerrace™ Light Control Panel (Capri

Model Only)

The AquaTerrace light control panel offers a variety of light settings described below.

Note:

Lights automatically turn off after 2 hours.

High MED LOW

The left button turns on, dims, and turns off the waterfall light(s) as shown.

x1 x2 x3

OFF x4

Left Button Controls The Waterfall Light(s)

High MED LOW OFF

Waterfall(s)

Footwell

The right button turns on, dims, and turns off the footwell light as shown.

x1 x2 x3 x4

Right Button Controls The Footwell Light

Page 51

880 SERIES

The center button selects random mode or one of

Random

Color

7 constant colors on the footwell and waterfall

x1

Freeze

Color x2

Blue x3

Purple x4

Red x5

Amber x6

Green x7

Aqua x8

Near

White x9

lights. In random mode,

Center Button Selects Waterfall And Footwell Light Color Mode press a second time to freeze random color or continue pressing for one of 7 constant colors. If you go past your favorite color, simply continue pressing to restart the color selection sequence.

10.9 Selecting The desired Massage Action

Your Sundance

®

hot tub is equipped to allow you to customize the massage action you desire. Each model incorporates a massage selector(s) that allows you to

B

C

A

customize the massage and performance by diverting water between various jet systems. Simply turn massage selector to position A (Combo),

B, or C to divert water pressure to various jet groups.

Note:

This valve is designed to operate in positions A (Combo), B, and

C for optimum performance. It is considered normal for sound levels within the valve to vary between positions due to the large amounts of water flowing through it. For optimum filtration benefits, leave the valve in position A when hot tub is covered. Select position B or C for maximum jet performance during hot tub use.

10.10 Adjusting Fluidix Reflex, Nex, ST, Intelli-Jets And

Focus-Relief

These jets in your new hot tub offer the advantage of no moving parts and zero maintenance. They can also be ad justed for a high and low impact massage, providing the ultimate massage! To adjust jets:

1. Fluidix Nex/Intelli-Jets and Reflex Jets only: Turn outer dial (A) clockwise to increase water volume. Turn outer dial

A

Fluidix Intelli-Jet counterclockwise to decrease water volume or to shut jet off.

2.

For a high impact massage, turn corresponding air control knob clockwise. For the Fluidix ST jet, this will create a straight water flow. For low impact massage, turn

A

Fluidix Reflex Jet corresponding air control knob counterclockwise. For the Fluidix ST jet, this will create an oscillating flow. Refer to Sections 9.4-9.25 (pages 2 5 -4 6 ) for specific operation details. The included tool (shown) allows you to position the jet nozzle angle to your liking. This tool can also be used to aid in the opening or closing of the nozzle on Fluidix ST jets.

3. Focus-Relief Jets: Work with both the blower and jets pump.

Fluidix ST Jet

The blower introduces air to the jet and the jets pump forces water through.

Note:

Always keep at least 6 adjustable jets open at all times on each jet system.

Page 52

Focus-Relief Jet

880 SERIES

10.11 Air Controls

Each jet system has its own air control. These controls allow you to regulate the amount of air which is mixed with the water entering through the jets. Clockwise rotation adds more air and counterclockwise rotation reduces air flow.

Note:

To minimize heat loss, close all air controls when spa is not in use.

Certain jets may not draw air while either jets pump is running in low speed; this is considered normal.

10.12 Waterfall Control

Turn waterfall control valve counterclockwise to increase waterfall(s) output. Turn control valve clockwise to decrease or turn off waterfall(s) output.

Note:

It takes 2 full revolutions to change the waterfall from a full off to a full on flow rate.

Full

ON

Full

OFF

2x

2x

10.13 Fragrance dispenser

On the rim of your hot tub is a screw-off cap labeled “SunScents

Fragrance Dispenser” (pages 2 5 -4 6 ). It is designed to contain packages of a specially made fragrance available from your Sundance Spas dealer. The fragrance is carried into the hot tub water by the air coming through the injector system when the air blower is on.

!

WARNING:

TO dECREASE RISk OF PERSONAL IN-

• jURY.

• Always turn off the air blower before removing or install-

• ing SunScents dispenser cap to reduce the risk of by having the dispenser and/or cap fly up.

Use only Sundance SunScents fragrances in your new hot tub, as the tub has not been tested for use with any

other manufacturer. Never use this dispenser for any other type of fragrance.

Never remove the SunScents beads from their plastic cage for any reason! This can cause damage to the spa equipment and plumbing lines.

The beads can also be ingested creating a chocking or poisoning hazard. keep away from children.

Install bead cage directly into SunScents dispenser.

Always make certain that the dispenser cap is securely in place before operating the hot tub’s air blower, to avoid the cap from flying off when the blower is activated.

Page 53

880 SERIES

10.14 Indicator Light

The indicator light located on the front cabinet panel of the hot tub is an early detection system that will notify you when the hot tub needs immediate attention. A solid white light indicates that all operations are normal. A solid red light indicates that immediate attention is required to clear or fix an error code. For a detailed explanation refer to Section 15.0, page

7 4

.

10.15 Optional Audio System

Sundance models with the optional audio system offer enhanced hot tub enjoyment by offering an integrated state-of-the-art audio system. These models include an integrated AM/FM/CD/iPod® Player receiver, high fidelity spa engineered speakers for unsurpassed sound quality and long-life, and an integrated subwoofer for an enhanced acoustical experience.

11.0 Heating Modes

The control system in your hot tub activates a programmable “Standard” or “Economy” mode which effects when the heater operates. Refer to

Sections 11.1 and 11.2 below for additional information.

11.1 Standard Mode (Factory default)

Standard mode is typically selected by customers in cold climates where heat up times are extended due to lower ambient temperatures. In this mode, water temperature is regulated by the set temperature which activates the heater automatically as needed.

11.2 Economy Mode

Economy mode is typically selected by customers in warm climates where heat up times are minimized due to higher ambient temperatures.

In this mode, the water temperature is regulated by the set temperature only when a programmed filter cycle is running.

11.3 Selecting Standard or Economy Mode

Press the

(MOdE)

button to select either “Standard” or “Economy” mode. The control panel’s indicator on the right side of the LCD changes to indicate which mode is selected.

Note:

“Standard” is shown when Standard Mode is selected. No display is shown when Economy Mode is selected.

Page 54

880 SERIES

11.4 Clean-Up “Blow-Out” Cycle

The clean-up cycle is once per day in both Standard and Economy modes at 12:00 (noon) for two minutes. This is not user programmable.

• Maxxus and Aspen Models: Jets pump 3 and blower activate for

• approximately 45 seconds to circulate any water in the plumbing.

Pump 3 shuts off, then pump 2 and the blower activate for approximately 45 seconds, then shut off. Finally, pump 1 activates and runs for approximately 30 seconds, then shuts off.

Altamar/Cameo/Majesta/Marin/Optima Models: Jets pump 2 and blower activate for one minute to circulate any water in the plumbing.

After 1 minute, pump 2 and blower shut off and jets pump 1 activates for 1 minute, then shuts off.

Capri Models: The blower activates for one minute to circulate any water in the plumbing. After 1 minute, the blower shuts off and jets pump 1 activates for 1 minute, then shuts off.

12.0 Programming Instructions

12.1 Programming Filter/Circulation Pump

The control system allows you to easily adjust two separate aspects of filter/circulation pump operation:

The time of day (start time) the filter/circulation pump turns on.

The length of time (duration) the filter/circulation pump operates.

The fac tory default start time is 12:00AM (midnight). The recommended factory duration is 8 hours. To make adjustments:

Standard Mode - in this mode, press the

(CYCLE)

once;

Economy Mode - in this mode, press the

(CYCLE)

button button five times to enter the filter/circulation pump programming mode.

The LCD screen will display

“Circ”

. At this time the system is ready to accept your changes.

1. Press the

(SELECT)

button once. The previously programmed start time appears on the LCD display.

2. Press the

(UP)

or

(dOWN)

time in 30-minute increments.

3. Press the

(SELECT)

4. Press the

(UP)

or

button to adjust the start button to program duration.

(dOWN)

duration time in 1 hour increments.

button to program the

Page 55

880 SERIES

5. Press the

(dISPLAY)

button to save changes and recall the main water temperature display.

Note:

If no button is pressed within 30 seconds, all changes are recorded and the screen automatically returns to the standard water temperature display. When the standard mode is selected (Section 11.3), the filter/circulation pump automatically turns on for a heat call regardless of the pump’s programmed start time and duration.

12.2 Programmable Filter/Heating Cycles (Economy Mode Only)

Your hot tub comes with four 30-minute filter cycles which activate the filter/circulation pump while in economy mode. These cycles are factory programmed to start at 6:00 AM, 12:00 (noon), 6:00 PM, and 12:00

(midnight). The control system allows you to easily adjust two separate aspects of each cycle:

The time of day at which it begins;

The duration of the cycle.

Note:

When “Economy” mode is selected (Section 11.3), the heater activates only during a programmed filter cycle period. When a Sum mer

Logic condition is active (page 56

), the filter/circulation pump will turn on for all programmed filter cycles.

Summer Logic:

In warm weather, the water temperature in the hot tub may exceed the set temperature. This condition may occur due to heat transference from the filter/circulation pump and jets pumps. If the water temperature is higher than 95°F (35°C) and rises two degrees above the set temperature, a “Summer Logic” condition occurs that deactivates the filter/circulation pump and

CLEARRAY™. This safety feature cannot be altered!

The filter/ circulation pump and CLEARRAY™ will remain off until the water temperature cools to the set temperature (except between 9am-

11am when the filter/circulation pump runs for it’s mandatory 2 hour cycle.)

Note:

Pressing the select button at this time will reactivate the circulation pump and waterfall feature for 1 hour. To help prevent a “Summer Logic” condition, it may be necessary to reduce filter/ circulation pump cycle run times in warm weather.

Press the

(MOdE)

button to select “Economy” mode. To make adjustments, first press the upper right corner:

(CYCLE)

*

button to enter the filter cycle programming mode. The LCD screen will display the following in the

*Note:

Number will vary according to which filter cycle is being programmed.

Page 56

880 SERIES

This means the system is ready to accept you changes to the start time for cycle number one. Simultaneously, the large four-digit display in the center of the screen displays the currently programmed start time for that cycle. At this point, you have four options. You may:

1. Press

(UP)

or

(dOWN)

increments of 30 minutes.

button to adjust the start time in

2. Press

(CYCLE)

button to display and adjust each subsequent cycles start time. With each press, the currently programmed status will be shown in the large four digit display. To adjust any displayed value, simply press the

3. Press

(SELECT)

(UP)

or

(dOWN)

button.

button to move down the menu from Start

Time to Duration, with each press, the currently programmed duration will be shown in the large four-digit display. Press

(UP)

or

(dOWN)

button to adjust the duration in increments of 15 minutes.

4. Press

(dISPLAY)

button to save changes and recall the main water temperature display.

Note:

If no button is pressed within 30 seconds, all changes are recorded and the screen automatically returns to the standard water temperature display.

*

*Note:

Number will vary according to which filter cycle is being programmed.

When a programmed filter/heating cycle activates, the LCD screen displays the following message

:

At any time, you may check the programming of any economy mode filter/ heating cycle by first pressing

(CYCLE)

the menu by pressing either

(CYCLE)

buttons during this process.

button then moving through or

(SELECT)

The programming is changed only by pressing

(UP)

button. or

(dOWN)

12.3 Adjusting Time of day

The control system remembers the time of day even in the event of a prolonged power outage. However, it may occasionally be necessary to reset the time of day. To accomplish this, press

(MOdE)

, and

(dISPLAY)

(dISPLAY)

,

button within five seconds each. A number representing the hour will be displayed, followed by AM or PM.

The hour will advance or decrease each time the

(UP)

or

(dOWN)

button is pressed within five seconds. Then, press the

(dISPLAY)

button again to display minutes. Adjust minutes as necessary by pressing the

(UP)

or

(dOWN)

button. After 5 seconds, the display will return to normal and save your settings.

Page 57

880 SERIES

12.4 Programming The date

The control system allows you program the month, day, year, and day of the week. To accomplish this, press

, and

(dISPLAY)

(dISPLAY)

,

(MOdE)

button within five seconds each. The current hour setting will be displayed, followed by AM or PM. Then, press the

(dISPLAY)

(dISPLAY)

pressing the

(UP)

button again to display minutes. Press the button again to adjust the month as necessary by or

(dOWN)

button. Press the

(dISPLAY)

button again to adjust the day by pressing the

(UP)

or button again to adjust

(dOWN)

(dISPLAY)

the

(UP)

button. Press the

(dISPLAY)

the year by pressing the

(UP)

or

(dOWN)

button. Press the button again to adjust the day of the week by pressing or

(dOWN)

button. After 5 seconds, the display will return to normal and save your settings.

Note:

The day of the week will be represented by a number rather than by name. The numbers will run consecutively from 1-7 with 1 = Sunday and 7 = Saturday.

12.5 Main Control Panel Lock

To help prevent unauthorized use of your hot tub, the controls incorporate a unique panel locking system which disables the controls on the panel.

• To Lock The Main Control Panel:

(MOdE)

Press

(dISPLAY)

,

buttons within five seconds , and

(UP)

each other. A padlock symbol will appear on the LCD screen. With the panel locked, all components are disabled from manual activation and the only settings that can be adjusted are the standard and economy filter/heating modes and time of day. All automatic hot tub functions will operate normally.

To Unlock Main Control Panel: Press

(dISPLAY)

(MOdE)

, and

(dOWN)

,

buttons within five seconds. The lock symbol will disappear. All buttons are now active.

LOCKED

12.6 Temperature Setting Lock

The hot tub’s temperature setting can be locked to prevent unauthorized changes. When locked, all other hot tub buttons and functions operate normally.

• To Lock Temperature Setting: Press

(UP)

or

(dOWN)

button to display temperature setting, then immedi ately press the

(dISPLAY)

,

(MOdE)

, and

(UP)

buttons within five seconds each. A padlock symbol

will appear on the screen.

To Unlock Temperature Setting:

(dOWN)

and immediately press the

(dOWN)

Press

(dISPLAY)

(UP)

,

(MOdE)

buttons within five seconds.

or

button to display temperature setting, then

,

LOCKED

Page 58

880 SERIES

12.7 Programming the Change Filter Reminder

Your new hot tu b is equipped with a programmable “Change Filter” reminder icon that flashes on the control panel display after a specified number of days. It is designed to remind you to perform routine filter system maintenance on a regular basis but does not affect hot tub operation in any way. The “Change Filter” reminder icon must be reset at each interval. It offers a selectable range from 10-120 days or can be disabled (turned off). We recommend an initial setting of 30 days

(1 month) to remind you of this important maintenance step.

Note:

This reminder must be reset at each filter inspection/replacement interval. Refer to Section 13.1 for filter replacement instructions.

Programming Instructions

1. Press the

(CYCLE)

button two times in Standard Mode, six times in

Economy Mode. The main display reads

“FIL” indicating the “Change Filter” display program has been accessed.

2. Press

(SELECT)

button once to display the currently programmed duration or to view days elapsed since last filter cleaning interval.

3. Press

(UP)

or

(dOWN)

button to change duration setting as follows: 0 - 10 - 20 - 30 - 40 - 50 - 60 - 70

- 80 - 90 - 100 - 110 - 120 - OFF.

Note:

Selecting “0” forces the Change Filter reminder icon to stay on indefinitely.

4. Press

(dISPLAY)

button once to save changes and return to the standard water temperature display.

Note:

If no button is pressed within 30 seconds, all changes are recorded and the screen automatically returns to the standard water temperature display.

12.8 Programming the CLEARRAY™ (Ultraviolet) Water

Purification System

To access the programming options follow the step below.

• Standard Mode - in this mode, press the button three

• times;

Economy Mode - in this mode, press the

(CYCLE)

(CYCLE)

seven times to enter the programming mode. button

The LCD screen will display “

U

”. At this time the system is ready to accept your changes.

1. Press the

(SELECT)

button once. The current status of the

CLEARRAY System appears on the LCD display, either “ON” or

“OFF”.

Page 59

880 SERIES

2. Press the

(UP)

or

(dOWN)

button to change the status of the CLEARRAY System from either “ON” to “OFF”.

Note:

If the “OFF” option is selected, then there is no need to continue with the steps below. Selecting “OFF” disables the duration countdown

button to return to the water timer. Press the

(dISPLAY)

temperature display.

3. Press the

(SELECT)

timer.

button to access the duration countdown

4. Press the

(UP)

button to program the duration countdown timer to 365 days. If the timer is not at “0” pressing the Jets pump 1 button will not reset it.

Note:

You can only program the duration if the number of days is at “0”

button days or the LCD display is flashing “blb”. Pressing the

(UP)

at any other reading will not change it.

5. Press the

(dISPLAY)

button to save changes and exit back to the water temperature display.

Note:

• Flashing “blb” message: When the time allotted has expired (365 days) the display screen will flash between the water temperature and “blb”. At this time the UV lamp must be replaced, the quartz tube must be cleaned and the duration countdown timer needs to be

• reset.

If the spa power is interrupted, the timer is not affected. The number of days remaining is stored in the memory and will continue to countdown once power is regained.

If you press the

(UP)

button to “ON” then press the

(dOWN)

to “OFF” and press the

(UP)

will reset the timer back to 365 days.

button to “ON” again, you

Page 60

880 SERIES

13.0 Hot Tub Maintenance

Proper and regular maintenance of your hot tub will help it retain its beauty and performance. Your authorized Sundance Spas dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this.

!

dANGER:

RISk OF SEVERE INjURY OR dROWNING

BY ENTRAPMENT!

Keep hair, loose articles of clothing or hanging jewelry away from suction fittings, rotating jets or other moving components to avoid entrapment that could lead to drowning or severe injury.

Never use the spa unless all suction guards, filter, filter lid, or skimmer assembly are installed to prevent body and/or hair entrapment.

Never operate or use the spa if the filter, filter lid, or skimmer assembly are broken or any part of the skimmer assembly is missing. Please contact your dealer or nearest service center for service.

The suction fittings and suction covers in this spa are sized to match the specific water flow created by the pump(s). If it is necessary to replace the suction fittings, suction covers or pump(s), be sure that the flow rates are compatible and are in

compliance with the VGB Safety Act page 2

.

Never replace a suction fitting or suction cover with one rated less than the flow rate marked on the original suction fitting.

Using improper suction fittings or suction covers can create a body or hair suction entrapment hazard that may lead to drowning or severe injury.

Owners must alert all spa users to the potential risk of Hair,

Limb, Body, Evisceration (disembowelment), and Mechanical

Entrapment, page 6.

13.1 Cleaning/Replacing the Filter Cartridge

A programmable “Change Filter” reminder icon flashes on the control panel display after a specified number days to remind you to perform routine maintenance on your filter system. This reminder must be reset at each interval. Refer to Section 12.7, for additional information and programming details.

Your Sundance hot tub is equipped with a two-stage MICROCLEAN®

Ultra filter cartridge assembly under the filter lid (Sections 9.4-9.25 pages 2 5 -4 6 ). Debris is filtered by the filter/circulation pump drawing water through the filter assembly 8 hours a day, 7 days a week (unless programmed otherwise). To ensure optimum performance, clean the outer pleated filter and center insert monthly. Then replace the center insert every 6 months, or as needed thereafter. Refer to procedure below for details.

Page 61

880 SERIES

All models include a suction cover filter (#6540-213) located directly under the MICROCLEAN® Ultra filter cartridge assembly that prevents debris from entering the hot tub plumbing when jets pump 1 is running. This filter should be cleaned every 2 months.

TO dECREASE RISk OF dEATH, dROWNING, OR ENTRAPMENT,

ALWAYS TURN POWER TO THE HOT TUB OFF BEFORE REMOVING

THE MICROCLEAN ULTRA FILTER ASSEMBLY!

Filter Cleaning/Replacement Procedure:

1

!

dANGER:

TURN POWER TO SPA OFF! TO dECREASE

RISk OF dEATH, dROWNING, OR ENTRAPMENT,

NEVER OPERATE SPA WHEN FILTER IS NOT PROP-

ERLY INSTALLEd OR IF WEIR ASSEMBLY IS dAM-

AGEd OR ALTEREd!

!

2

2

1

Filter Nut

Filter Cleaning Requirements:

• Clean MICROCLEAN Ultra Pleated

Filter (1) monthly and replace every

18 months (6473-165).

Rinse off MICROCLEAN Ultra Insert

(2) monthly and replace every 6 months or as needed (6473-164).

Filter Removal Instructions:

Loosen filter nut to provide clearance, then remove MICROCLEAN Ultra Filter

Assembly from spa.

3

Monthly Filter Cleaning Procedure

We recommend cleaning the outer pleated filter (1) with a high pressure water nozzle and the filter insert (2) with a low-pressure water nozzle monthly. Periodically, the outer pleated filter cartridge

(1) will require a more thorough cleaning to remove embedded oils and minerals by using special spa filter cleaners offered by your spa dealer. Always remove the center filter insert (2) before cleaning the outer filter (1) with chemicals. Never use filter cleaners of any kind on the filter insert (2) or it may be damaged, come apart or allow impurities to re-enter the water, increasing the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments.

Procedure:

1. Grasp center filter insert end cap (2) in hand and pull outward from pleated cartridge (1). If filter insert (2) is 6 months old, throw it away and purchase new one. DO NOT install new insert at this time.

Page 62

880 SERIES

2. Rinse debris from all outer filter

(1) pleats using a garden hose and high-pressure nozzle. Repeat process until all filter pleats are clean. Then rinse debris from inside of filter (1). If chemical cleaners are used, follow manufacturers instructions.

Top

1

1

Lightly rise filter insert (2) and place in clean location. *DO NOT use chemical cleaners or high-pressure nozzle on insert (2) or it may be damaged, come apart or allow impurities to re-enter the water, increasing the risk of contracting a waterborne illness (e.g. an infection bacteria or virus) and/or respiratory ailments.

2

2*

3. Install filter insert (2) into outer pleated filter (1) by gently sliding inward until a slight resistance is felt approximately 1/4" from bottom. Lightly tap insert end with palm of hand to “snap” in place. Insert is properly installed when end cap rests “flush” against outer filter end cap.

4. Install Filter assembly back into spa by performing step 2 in reverse order. Tighten filter nut so it just touches the filter face. DO NOT

OVERTIGHTEN!

5. Turn power to spa back on.

Replacement filter cartridges may be purchased from your Sundance

Spas dealer.

13.2 Quick Release door (Except Maxxus and Aspen Models)

The Quick Release Door provides easy access to the equipment bay and components without having to unscrew the panel. To remove the

Quick Release Door follow the steps below:

1. Locate the two Quick Release Door buttons on the top corners of the center panel, Figure A.

2. Press the buttons to release the panel from the spa frame, Figure B.

3. Slowly and gently tilt the panel forward to remove.

This will expose the equipment bay for easy access to components like the CLEARRAY

System and the Quick Drain Valve, Figure

C. Place the panel in a safe location to prevent from damaging it.

4. To reinstall the panel just follow the steps above in reverse order.

SENTRY

Figure A

Figure B

Figure C

Page 63

880 SERIES

13.3 Draining And Refilling

About every 3 to 6 months, you will should replace the hot tub’s water.

The frequency depends on a number of variables including the amount of use, attention paid to water quality maintenance, etc. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water even though the key water balance measurements are all within the proper parameters.

!

CAUTION! REAd THIS BEFORE dRAINING:

To decrease damage to the hot tub’s components, turn off power to the hot tub at the circuit breaker before draining it. Do not turn the power back on until your hot tub has been refilled. There are certain precautions to keep in mind when draining your hot tub. If it is extremely cold, and the hot tub is outdoors, freezing could occur in the lines or the equipment (see “Winteriz ing”,

page 67)

. On the other hand, if it is hot outdoors, do not leave the hot tub’s surface exposed to direct sunlight for long periods.

draining Procedures:

1. Turn off power to hot tub at breaker.

2. Locate the 3" gray drain valve cap on side of the hot tub cabinet. Unscrew drain valve cap to expose the underlying male garden hose fitting

(Figures A-B).

3. Attach female garden hose end to drain fitting and route opposite end of garden hose away from hot tub (Figure B).

4. Pull outward on garden hose end at drain connection (approx. 3/8") to open drain valve and release water from hot tub (Figure C). Water drains at approximately 3 gallons per minute.

5. After hot tub has drained, close drain valve by pushing inward on garden hose end at drain connection until you feel it bottom out. Remove garden hose and install gray drain cap before refilling hot tub.

Note:

The gray drain cap cannot be installed until the drain valve is closed. Refer to “Hot Tub Fill Up Procedure” (

page 17) for

recommended filling instructions.

Page 64

880 SERIES

draining Procedures (Quick drain):

1. Turn off power to hot tub at the breaker.

2. Locate the two Quick Release Door buttons for the center cabinet, (Figure A). Press the buttons to release the panel from the spa frame. Gently pull the cabinet forward and off (Figure B). Place the panel in a safe location to prevent from damaging it.

Note:

For the Maxxus and Aspen models the front panel must be unscrewed to be removed.

3. Locate the Quick Drain Valve. Unscrew drain valve cap (Figure C). Place the cap aside.

4. Screw in the adapter with hose that was included in the equipment bay, attached to the quick drain (Figure D). Make sure to direct the hose to an area where the water will drain properly.

5. Open the drain slice valve by sliding the

SENTRY

Figure A

Figure B handle to the side and pulling up.

Figure C

6. After the hot tub has drained close the slice valve by pushing

Figure D it downward and sliding the handle to the side. Remove the adapter and reinstall the Quick drain cap before refilling hot tub.

13.4 Cleaning The Hot Tub Interior

To preserve the sheen of your hot tub’s surface, it is crucial that you avoid using abrasive cleaners or cleaners which have adverse chemical effect on the surface. If you are not certain as to the suitability of a particular cleanser, consult your authorized Sundance Spas dealer.

Regardless of the cleanser used, use extreme care to assure that no soap residue is left on the surface. This could cause severe sudsing when the hot tub is refilled.

13.5 Pillow Care (except Capri model)

Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. Always remove the pillows when adding chemical shock treatment to the spa water. The pillows can be returned to the spa when the sanitizer reading is stable as recommended on the inside cover of the manual.

Page 65

880 SERIES

1 2

3 4

Place both hands on pillow with thumbs as shown.

Press inward with thumbs to curl pillow lip inward so you can grab it with fingertips.

Flex pillow lip inward

2-3" to get a good grip on the ends.

Gently pull outward on pillow to release mounting stud from receptacle on spa shell.

5

Wash pillow(s) in a mild detergent soap and warm water solution. Never machine wash your pillows or attempt to clean them with a cleaning agent!

6

To reinstall pillows: Simply align pillow over mounting stud receptacle, then gently push inward to snap in place.

13.6 Pillow Care (Capri model only)

Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. To maintain water resistance and luster, apply a quality vinyl conditioner once a month.

!

IMPORTANT:

Never attempt to remove the pillows by pulling on them! The pillows utilize a bolt-on design that prohibits removal without tools.

To remove pillows:

1. Grasp center pillow insert (A) with finger tips and gently pry outward from pillow base (C).

2. Use a standard screwdriver to loosen and remove mounting bolts

(B) from pillow base.

3. Assemble in reverse order after cleaning. DO NOT overtighten pillow mounting bolts!

13.7 Maintaining the Hot Tub Cabinet

The hot tub cabinet require little or no maintenance of any kind. To clean, wipe cabinet with a clean towel and mild detergent soap solution.

CAUTION:

Never spray cabinet with a high pressure garden hose for any reason since this action may induce an electrical short in the hot tub’s electrical equipment.

Page 66

880 SERIES

13.8 Vinyl Cover Care And Maintenance

Using the Sundance insulating spa cover anytime the spa is not in use will significantly reduce your operating costs, heat-up time and maintenance requirements. To prolong the life of the cover, handle it with care and clean it regularly. Below are the care instructions.

A.

To Clean and Condition the Vinyl Cover

1. Use a garden hose to loosen debris and dirt.

2. Using a large sponge or a soft bristle brush, use diluted or mild soap and scrub the vinyl top. Rinse clean and do not allow soap to dry on cover. Do not use soap on the underside of the cover.

3. Please check with your Sundance Spa Dealer for recommended cover care and conditioning products. Condition using non-petroleum based conditioners to keep the vinyl supple and threads/stitching from drying out. Do not use solvents, abrasive cleaners or strong detergents. Do not use products that contain silicone or alcohol.

B.

Additional Care and Maintenance Instructions:

1. Debris can accumulate on the spa cover. Removal of snow or other debris will help to avoid breakage of the foam cores.

2. Be sure to lock the cover straps to secure the cover from unwanted or accidental entry.

3. Do not place heavy objects on the vinyl.

4. Do not walk, sit or stand on the cover.

5. Do not drag or use the flaps/skirt or the cover lock straps to remove the cover.

6. Use only recommended cover lift systems.

7. Use only chemicals and cleaners recommended by Sundance Spas.

8. Remember to keep spa covered when not in use. Maintaining proper water levels assures efficient operation and efficient electrical usage.

9. Do not expose your spa to the sun for extended periods of time as

UV rays can damage the interior surface.

10. Use caution when removing cover. Before removing cover, assure all locks have been released to avoid lock breakage and/or cover strap damage.

13.9 Winterizing

Your Sundance hot tub is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the electri cal supply to the hot tub has not been interrupted. In extreme, bitter cold weather (less than -20°F) verify standard mode is selected (Section 11.1) to protect the hot tub from freezing.

If you do not intend to use your hot tub, or if there is a prolonged power outage during periods of severe freezing temperatures,

it is important that all water be removed from the hot tub and equipment to protect against damage from freezing.

Page 67

880 SERIES

Expert winterization of your spa is highly recommended,

contact your authorized Sundance Spas dealer. In emergency situations, damage can be minimized by taking the following steps:

CAUTION: TURN OFF POWER TO HOT TUB!

1. Follow the directions (Section 13.3) for draining the hot tub.

2. Turn the massage/diverter selector(s) to the middle combo position

to allow the water in the plumbing lines to drain, see page 5 2 .

3. Turn the waterfall valve(s) to the open position to allow the water in

the plumbing lines to drain, see page 5 3

.

4. As the water level drops below the seats, use whatever means necessary to get the water out of the recessed seating areas and into the footwell, such as a wet/dry vacuum.

5. When the water level ceases to drop, use whatever means available to remove any remaining water from the footwell, such as a wet/dry vacuum.

6. Remove the equipment-side cabinet panels and locate the drain plugs

in the front of each pump (Figures A and B, pages 1

31 4). Remove

these plugs to allow the water to drain out of the pumps and heater.

Note:

Approximately 1 to 2 gallons will be released during this procedure. Use a wet/dry vacuum or other means to keep this from flooding the equipment compartment. Replace the drain plugs.

7. Loosen hose clamp at bottom of heater (Figures A and B, pages

1 3-

1 4) and pull hose off of heater fitting (twist the hose back and

forth while pulling downward). Tip hose down and allow to drain, then reinstall hose and clamp.

8. Loosen hose clamp at bottom of CLEARRAY™ system and pull hose off of CLEARRAY fitting (twist the hose back and forth while pulling downward). Tip hose down and allow to drain, then reinstall hose and clamp. Remove the cover of the CLEARRAY system to access the UV lamp and quartz tube. Remove and store the UV lamp in a safe location. Remove and dry off the quartz tube then reinstall it.

Depending on the length of time, consider replacing the UV lamp when you resume use of your hot tub.

9. Re-install cabinet side panels and cover hot tub so that no moisture can enter into it. Consult your Sundance Spas dealer if you have any questions regarding winter use or winterizing.

13.10 Restarting Your Hot Tub in Cold Weather

If you want to start up your hot tub after it has sat empty for a time in freezing temperatures, be aware that the water remaining in certain sections of the piping may still be frozen. This situation will block water flow preventing the hot tub from operating properly and possibly damaging the equipment. We recommend you consult your dealer for guidance before attempting to restart your hot tub under these conditions.

Page 68

880 SERIES

14.0 Water Quality Maintenance

To decrease the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments , maintain water quality within specified limits. This will enhance your enjoyment and prolong the life of the hot tub’s equipment. Doing so requires regular attention because the water chemistry involved is a balance of several factors. Procrastination in regard to water maintenance will result in poor and potentially unhealthful conditions for soaking and even damage to your hot tub investment. For specific guidance on maintaining water quality, consult your Authorized

Sundance Spas dealer who can recommend appropriate chemical products for sanitizing and maintaining your hot tub.

!

WARNING:

FAILURE TO MAINTAIN WATER QUALITY

WILL:

• Increase risk of contracting a waterborne illness (e.g. an

• infection bacteria or virus) and/or respiratory ailments .

Damage the equipment, components and spa shell, which are not covered under the hot tub’s warranty.

CAUTION:

Never store hot tub chemicals inside the hot tub’s equipment bay. The equipment bay may reach elevated temperatures, this is where high voltage electronic devices are located. This area is not intended for storage of any kind.

14.1 pH Control

pH is a measure of relative acidity or alkalinity of water and is measured on a scale of 0 to 14. The midpoint of 7 is said to be neutral, above which is alkaline and below which is acidic. In hot tub water, it is very important to maintain a slightly alkaline condition of 7 .4 to 7.6 pH . Problems become proportionately severe the further outside of this range the water gets.

A low pH will be corrosive to metals in the hot tub equipment. A high pH will cause minerals to deposit on the interior surface (scaling). In addition, the ability of the sanitation agents to keep the hot tub clean is severely affected as the pH moves beyond the ideal range. That is why almost all hot tub water test kits contain a measure for pH as well as sanitizer.

14.2 Sanitizing

To destroy bacteria and organic compounds in the hot tub water, a sanitizer must be used regularly. Your Sundance hot tub is equipped with the Brominator™, a special compartment built into the floating skimmer gate to hold the SunPurity™ mineral cartridge designed specifically for your hot tub or bromine tablets. By regulating the number of bromine tablets in the Brominator you can control the amount of bromine, which is actively working, in your hot tub water. A bromine residual of no less than

2.0 ppm is generally considered desirable. A two-part bromine system or granular chlorine (dichlor) are also acceptable sanitizers. When adding spa shock (chlorine or non-chlorine) or pH balancing chemicals, activate

Page 69

880 SERIES

the jets pump(s) and leave the spa cover open for a minimum of 20 minutes. By doing this you will allow excess chemical vapors to exit the spa, protecting pillows and plastic knobs from chemical attack.

!

WARNING:

RISk OF PERSONAL INjURY, dROWNING

OR ENTRAPMENT!

Never leave your hot tub unattended for any reason while the cover is open and accessible, especially to small children and animals!

CAUTION: RISk OF PERSONAL INjURY OR SPA dAMAGE!

Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemical may damage components within your hot tub, burn or irritate your skin, create a rash, and void the manufacturer warranty for your spa.

14.3 CLEARRAY™ Water Purification System

Your new hot tub has our water purification system factory installed that will begin disinfecting your water instantly. CLEARRAY Water Purification System is exclusive technology utilizing natural ultraviolet technology to sanitize your water, disinfecting bacteria, viruses, and algae in portable hot tubs. The ultraviolet light otherwise know as UV-C or germicidal light inactivates the microorganisms by disrupting

WARNING!

DO NOT LOOK AT LIT BULB

SEVERE EYE DAMAGE

OR BLINDNESS CAN OCCUR the DNA so that it cannot reproduce and is considered lifeless.

The ballast is the power supply for the purification system; it has two LED indicator lights the green indicating incoming power flow and the red indicating the system is properly working.

CLEARRAY is standard for all models.

Note: The CLEARRAY System only runs when the circulation pump is running and shuts off when either jets pump is manually activated during spa use. The system will remain off for 5 minutes after both jets pumps time out or are manually turned off, then resume operations if the circulation pump is programmed to run.

After a year the lamp must be replaced. A message will appear on the

LCD display when the time allotted has expired. In order to clear the “blb” message a new UV lamp needs to be installed and the timer must be

reset (Sec. 12.8, page 59).

Page 70

880 SERIES

14.4 CLEARRAY™ Lamp Replacement and Quartz Tube

Maintenance

Important:

It is

MANdATORY

that the UV lamp is replaced and the quartz tube be cleaned every 12 months to maintain optimum performance.

9 10

1

2

4

6 7

8

3

13

5

11

Figure 1

12

!

!

!

dANGER:

TURN THE SPA BREAkER TO THE OFF

POSITION!

WARNING:

ALLOW LAMP TO COOL dOWN PRIOR TO

REMOVING FROM QUARTZ TUBE.

dANGER:

NEVER LOOk AT THE LIT BULB. THIS CAN

CAUSE SEVERE EYE dAMAGE OR BLINdNESS.

UV lamp replacement and quartz tube maintenance:

Note:

Location of CLEARRAY System and connection may vary by model.

1. Turn the breaker to the spa OFF. We recommend that you drain your spa. Disconnect the

CLEARRAY System from the controller, Figure 2.

2. Once the UV lamp has cooled off remove the

CLEARRAY System enclosure cover (10) and gasket (9) by removing the four screws (11).

SPA CONTROLLER

Connection

!

UV Unit

Figure 2

dANGER:

NEVER REMOVE COVER WITHOUT FIRST

TURNING OFF AT POWER SOURCE.

7

Figure 3

Figure 4

Figure 5

4

8

4

5

3. Remove the black lamp boot (8) by sliding it over the cable away from the quartz seal compression nut (7), Figure 3.

Page 71

880 SERIES

4. Slowly remove the UV lamp (4) out of the quartz tube.

5. Remove lamp socket (5) from the UV lamp (4), Figure 4.

6. Remove the quartz seal compression nut (7) by turning it

counterclockwise,

Figure 3. Use a pair of channel-lock pliers if needed, Figure 5. You will notice that there is a stainless steel compression washer (6) that slides over the quartz tube. Save the washer (6) for later use, Figure 6. There is also a black seal ring (13), grasp the black seal ring, slowly and carefully remove the quartz tube.

2

7

6

13

Figure 6

7. Now you are ready to clean or replace the quartz tube (2). For the cleaning of the quartz tube (2), follow steps 8 and 9 then proceed to step

10. For replacing of the quartz tube (2), skip steps 8 and 9 and proceed to step 10.

8.

Cleaning quartz tube:

Clean the quartz tube by wiping until clear using a paper towel or a dry cotton cloth . If needed a household tub and shower lime removal product can be used.

!

WARNING

:

Do not use abrasive cleaners as they can scratch the quartz tube surface.

9. Rinse the quartz tube with clean water to completely remove any cleaning products that were used in step 4.

10.

Replacing quartz tube:

You will notice that the new quartz tube does not have a black cushion on the domed end as the old quartz tube does. This is normal as the cushion was provided with the original quartz tube to protect it from breakage during transportation. Install the black seal ring (13) over the opened end of the quartz tube. Place the new quartz tube (2) into the water chamber (1) with the domed end first making sure it is inserted and seated inside the quartz end holder.

Only a small portion will be exposed when it is seated correctly.

11. Reinstall the compression washer (6) over the open end of the quartz tube (2). Push it against the quartz black seal ring (13).

12. Reinstall and hand tighten the quartz seal compression nut (7) by turning it

clockwise

.

13. Refill your spa.

14.

System Test 1:

Assure there is no water dripping from the seal compression nut (7). If water is visible, STOP and tighten the compression nut (7) using a pair of channel lock pliers to a maximum of 1/4 turn. If that does not fix the leak, then repeat quartz tube maintenance process from step 1 through step 13. Make sure there is no water leaking before proceeding to step 15.

15.

System Test 2:

Turn breaker back ON. Turn on the pump to circulate the water through the CLEARRAY System. Wait for 5 minutes and assure no water is dripping. If water is visible, STOP, fix the leak by repeating quartz tube maintenance process from step 1 through step 14.

Make sure there is no water visible and turn the pump and breaker OFF BEFORE proceeding to step 16.

Page 72

880 SERIES

16. Reconnect the lamp socket (5) to the new UV lamp (4) make sure you use the latex glove provided when handling the UV lamp.

Note:

Align pins on UV lamp (4) to the receptacle holes on the lamp socket (5) before inserting the pins completely into socket holes. Fail ure to do so will damage the UV lamp.

!

WARNING:

DO NOT TOUCH THE NEW UV LAMP WITH

YOUR BARE HAND. Oil on your skin will cause hot spot on the UV lamp and shorten the life of your UV lamp. Use the provided latex glove to handle the UV lamp.

17. Slide the new UV lamp (4) back inside the quartz tube, Figure 3.

18. Reinstall the black lamp boot (8) back over the quartz seal compression nut (7).

19. Reinstall the enclosure cover (10) with gasket (9) and secure with the screws.

20. Reconnect the CLEARRAY System to the controller and turn on the power to the spa.

21. Properly dispose of the old UV lamp.

!

WARNING:

This CLEARRAY System includes a UV lamp, which contains mercury. Dispose of the lamp in accordance with disposal laws. See www.lamprecycle.org.

22. Once power is activated you can check the ballast

(12), Figure 7, to see if the CLEARRAY System is functioning. A solid green light indicates that the

CLEARRAY System is being provided power and should always be on. A solid red light indicates that

UV lamp is activated.

Indicator

Lights

Figure 7

14.5 Other Additives

Many other additives are available for your hot tub. Some are necessary to compensate for out-of-balance water, some aid in cosmetic water treatment and others simply alter the feel or smell of the water. Your Authorized

Sundance Spas dealer can advise you on the use of these additives.

14.6 Handrail Maintenance

The handrails in your Sundance hot tub are manufactured from a high quality 316 stainless steel alloy. Many people are familiar with the term

“stainless steel” and are surprised to learn that it does indeed rust and corrode in the presence of chloride salts, free chlorine, or sulfide gasses.

The bad news is the environments that produce these elements are ocean spray, salted highways, chemical treatments added to swimming pools and hot tubs, and ground water in numerous coastal areas. The good news is with proper care, your hot tub’s handrails can maintain their original finish.

Page 73

880 SERIES

If your stainless handrails shows signs of rusting you should:

Wash with fresh water (a good detergent won’t hurt).

Clean with a good car chrome polish.

Wax with an automotive or fiberglass wax.

You should never:

Clean with chlorinated cleaners or scouring powders.

Use sand paper, “Scotch Brite”, Brillo pads, or similar abrasive products.

Clean with muratic or hydrochloric acids. Vinegar is ok, but it won’t do much to remove rust.

15.0 Troubleshooting - display Messages

There are a number of unique functions designed into your

Sundance hot tub to protect it from damage and/or to aid in troubleshooting. The indicator light located on the front cabinet panel of the spa is an early detection system that will notify you when the spa needs immediate attention. A solid white light indicates that all operations are normal. A solid red light indicates that immediate attention is required to clear or fix an error code. Following is a listing of all the possible messages along with their meanings. Always insist on genuine Sundance replacement parts.

Error Logo Light Error

OH Red - - - -

COOL

FLO

White

Red

SN1

SN3

HOT

ICE

PNL

White

White

Red

FLO2

ICE2

Logo Light

Red

Red

Red

Red

Red

Page 74

880 SERIES

MESSAGE MEANING

!

WARNING: RISk OF HYPERTHERMIA

(OVER-HEATING) CAUSING SEVERE

INjURY, BURNS, OR WELTS.

Overheat Protection (Heater is deactivated, filter/ circulation pump is activated). Water temperature is above acceptable limits.

dO NOT ENTER THE

WATER

! Remove hot tub cover to speed cooling.

See “Water is too hot” (

page 78)

. If condition persists, contact your Sundance Spas dealer or qualified service technician.

If the hot tub water is more than -7°C cooler than the temperature setpoint, jets pump #1 and heater will automatically activate to provide freeze protection.

The hot tub will stay in this mode until the water temperature reaches 15 degrees below the set temperature. No corrective action is necessary.

*

F LOW SWITCH (Heater is deactivated. The filter/ circulation may also be deactivated). Proper flow of water is inhibited or a flow switch has malfunctioned.

Check for proper water level and for clogged filter

(pages 61

6 2 ). Contact your Sundance Spas dealer

or qualified service technician.

*Note:

This message can also appear if the pump has not regained prime after the hot tub has been drained and refilled. If you suspect that

this is the case, see the instructions on page 77 under “pump does not

operate and icon does”.

Circuit board temperature has exceeded acceptable limit. This message will disappear when the circuit board temperature drops below acceptable limit. If condition persists, provide shade for equipment side of hot tub.

FREEZE PROTECTION

A potential freeze condition has been detected. No action is required. Jets pump(s) operate until the hot tub is out of danger.

Note:

This error commonly occurs when the hot tub is first filled because tap water is often very cold.

Page 75

880 SERIES

Power failure. Power fluctuation in the secondary power line is causing the DC voltage to be low. Try to reset power to spa. Should the power level return to normal, the PF error will reset itself. If the error returns, contact your Sundance Spas dealer or qualified service technician.

Power failure. Power fluctuation in the secondary power line is causing the DC voltage to be low. Try to reset power to spa. Should the power level return to normal, the PF error would reset. If the error returns, contact your Sundance Spas dealer or qualified service technician.

!

WARNING: RISk OF HYPERTHERMIA

(OVER-HEATING) CAUSING SEVERE

INjURY, BURNS, OR WELTS.

“WATCHDOG” (hot tub is deactivated). Water temperature is above acceptable limits.

dO NOT

ENTER THE WATER

! Remove hot tub cover to speed cooling. A problem has been detected which could cause damage to the hot tub or its components. Contact your Sundance Spas dealer or qualified service technician.

OPEN SENSOR (heater disabled) or SHORTED

SENSOR (hot tub is deactivated)

The high-limit temperature sensor is non-functional.

This must be repaired only by an Sundance Spas dealer or qualified service technician.

OPEN or SHORTED SENSOR (heater disabled)

The main temperature sensor is non-functional. This must be repaired only by an Sundance Spas dealer or qualified service technician.

CLOSED or SHORTED FLOW SWITCH ON

SYSTEM STARTUP (system disabled) Flow switch is non-functional. This must be repaired only by an

Sundance S pas dealer or qualified service technician.

UV lamp needs to be replaced. The message will flash between “blb” and the water temperature. The countdown timer for the UV lamp needs to be reset

(Section 12.8, page

59 ). A new UV lamp can be

purchased from a local Sundance Spas dealer.

Page 76

880 SERIES

16.0 Troubleshooting - Procedures

In the unlikely event your hot tub is not working the way you believe it should, please first review all the installation and operating instructions in this manual and check the message on the panel display; second, if you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions.

PROBLEM

None of the components operate ( i.e. pump, blower, light)

Pump does not operate and icon does

PROCEdURE

Check the control panel lights.

1. If there are letters or symbols displayed on the screen, refer to the previous section to determine meaning and action required.

2. If nothing appears on the screen:

A. Check the household circuit breaker.

B. Contact you Sundance Spas dealer or qualified service technician.

Depress JETS Button.

1. If no sound is detected or if a buzzing sound is detected, turn off power to the spa and contact your authorized dealer or qualified service technician.

2. If motor operates, but now water flows to jets:

A. Pump may not be properly primed. See instructions below.

B. Contact your Sundance Spas dealer or qualified service technician.

Pump Priming Instructions:

This method must be used for the jets pumps because these pumps are not connected to the main filter system in any way.

1. Turn off the power to the spa.

2. Remove the handle from the massage selector supplied by the pump you are priming.

3. Loosen the massage selector’s cap slightly (counterclockwise), listening for the air to seep out.

4. Tighten the cap finger tight, replace the handle, and turn the spa’s power back on.

CAUTION:

If freezing conditions exist and pump is not operational, take measures to protect the system from freeze damage. See Section titled “Winterizing”,

page 67.

Page 77

880 SERIES

PROBLEM

Poor jet action

(Sections

9.4-9.25, pages 2 5 -4 6)

Water is too hot

No heat

Filter/ circulation pump off

PROCEdURE

1. Make certain the jets pump is turned on.

2. Check position of massage selectors.

3. Open air control for selected jet system.

4. Check for adequate water level.

5. Check for dirty filter (pages

61

6 2 ).

1. Reduce thermostat setting (page

18).

2. Switch hot tub to “Economy” mode to turn heater on

only during programmed filter cycles (page 55).

1. Check thermostat setting.

2. Keep the cover in place while heating.

3. If “heater on” indicator is lit but no temperature rise is experienced after a reasonable period of time, con tact your Sundance Spas dealer or qualified service technician.

1. Verify filter/circulation pump is programmed to run 8

hours a day (page 55).

2. Filter/circulation pump cycle canceled by power interruption. Wait 24 hours for hot tub to reset or press select button for manual activation.

3. Hot tub water is warmer than 95°F (35°C) and two degrees warmer than the set temperature. The

“Summer Logic” safety feature has activated. See

note on page 56 for details.

Should checking the above steps fail to correct the problem, please call your authorized dealer so that he may arrange service.

Sundance builds the best hot tubs in the industry. Nonetheless, we are always striving to improve the quality and features of our products. Your input as a Sundance hot tub owner is a cherished part of this process. If you have any comments or suggestions, or if you wish to be informed on any new products for your hot tub, please write to us.

CONGRATULATIONS

on your good taste and welcome to the happiest and most relaxed family in the world!

Page 78

880 SERIES

17.0 North American 60 Hz Electrical Wiring diagram

17.1 North American 60 Hz Maxxus/Aspen Electrical Wiring diagram

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

STEREO (Optional)

30A, 250V SC-30

To Pump 2 Relay & Heater Relay

To Contactor KX-1 (2 Wires) & Fuse FX (1 Wire)

75ºC WIRE SIZE. WIRE SIZE MUST BE APPROPRIATE PER NEC AND/OR LOCAL CODES. THE MAX SUPPLY CONNECTOR AMPACITY IS 60A. THE AMPERE RATING OF SUPPLY CONDUCTOR OVERCURRENT PROTECTIVE DEVICE IS 60A.

From Contactor KX-3

Light DCU

Accessories Air control light rings W Footwell Grab bars

constant voltage (connect to the yellow wires on the

See Jumper Settings in owners manual

1 3 5 7 9 11 1 3 5 7 9 11 13 15

From TB1

T92 Pump 2 Relay

From Contactor KX-2

EXTERNAL SERVICE PANEL BOX DISCONNECT MEANS MUST BE LOCATED NO CLOSER THAN 5 FT. (1.52m) FROM THE INSIDE WALLS OF THE SPA AND WITHIN SIGHT OF SPA

20A, 250V MDA20

To Fuse F2 & Heater Relay (2 Locations)

Page 79

880 SERIES

17.2 North American 60 Hz Altamar/Cameo/Capri/Majesta/Marin

Electrical Wiring diagram

01 TB5 403 TB 02 TB4 04 TB4 01 TB4

Aquaterrace Light Control Panel (Capri Model only)

Accessories Air control light rings W

Light DCU

Aquaterrace Light Control Panel (for Capri) or Control Panel (for other 880 models)

constant voltage (connect to the yellow wires on the

ANEL

1 3 5 7 9 11

1 3 5 7 9 11 13 15

LCDP 800

See Jumper Chart In owners manual

Page 80

EXTERNAL SERVICE PANEL BOX DISCONNECT MEANS MUST BE LOCATED NO CLOSER THAN 5 FT. (1.52m) FROM THE INSIDE WALLS OF THE SPA AND WITHIN SIGHT OF SPA

Turn power off before servicing. This task should only be performed by a quali

880 SERIES

18.0 Export 50 Hz Electrical Wiring diagram

18.1 Export 50 Hz Maxxus/Aspen Electrical Wiring diagram

Light DCU

Accessories Air control light rings W Footwell Grab bars constant voltage (connects to the

See Jumper Chart in owners manual

1 3 5 7 9 11 1 3 5 7 9 11 13 15

This equipment was tested and found to be fully compliant with EN55014-1 (1997), EN55014-2 (1997), EN61000-3-2 (1995), EN61000-3-3 (1995), EN55022 Class B, and EN50082-1 (1992) Standards.

30A, 250V SC-30

To Heater Relay

Turn power off before servicing. This task should only be performed by a quali

Page 81

880 SERIES

18.2 Export 50 Hz Altamar/Cameo/Capri/Majesta/Marin Electrical

Wiring diagram

Aquaterrace Light Control Panel (Capri Model only)

(Not available in Capri models)

20A, 250V SC-20

STEREO (Optional)

1 Pump = 12A/24A; 2 Pump = 18A/30A USE MIN. 8 mm

See Jumper Chart in owners manual

1 3 5 7 9 11 1 3 5 7 9 11 13 15

Light DCU

Accessories Air control light rings W Footwell Grab bars

Aquaterrace Light Control Panel (for Capri) or Control Panel (for other 880 models)

constant voltage (connect to the yellow wires on the

Page 82

RISK OF SHOCK OR ELECTROCUTION!

Turn power off before servicing. This task should only be performed by a quali

880 SERIES

19.0 Circuit Board Pin Assignments

!

DANGER

RISK OF SHOCK OR

ELECTROCUTION!

850 LCD

REVX.XX

JP19

1

3

7

9

11

15

5

7

1

3

JP19

JP9

JP9

Turn power off before servicing. This task should only be performed by a qualified technician.

Refer to pages

15 -

16

for additional jumper configuration details.

JP19-1 On = °C Off = °F

JP19-3 On = 50 Hz Off = 60 Hz

JP19-5

On = Enables the logic for the Incandescent Light

Off = Enables the logic for the Multi-Color LED Light

JP19-7 Not used

JP19-9 On = Enables Pump 1, 2-Spd logic

Off = Enables Pump 1, 1-Spd logic

JP19-11 Not used

JP9-1

JP9-3

JP9-5

JP9-7

On

Not Used

Not used

On = 60A Logic Off = 50A Logic (See Section 7.0 pages

15

16 for logic details)

JP9-9

JP9-11

On = 2 or 3-Pump Logic Off = 1 Pump Logic

On = 40A Logic (See pages

15

16 for logic details)

JP9-13 Not used

JP9-15 Off

Page 83

880 SERIES

20.0 Typical Hot Tub Wiring diagrams A-B (North American 60 Hz Models Only)

!

DANGER

RISK OF SHOCK OR

ELECTROCUTION!

Turn power off before servicing. This task should only be performed by a qualified technician.

A

2-Pole Circuit Breaker with 2-Wire Grounded Load Connection

(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)

240 VAC

White (N)

Black (L1)

Red (L2)

2-Pole

GFCI

Breaker

R

TB1

B

SPA CONROLLER

Main

Service

Panel with

GFCI

Red (L2)

Black (L1)

TB2

Green

No Load Neutral Wire

Pigtail

Neutral Bus

Ground

Ground/Bonding Lug**

Note: service disconnect not shown in this diagram.

The control box TB1 terminal position varies between models.

Page 84

B

Main Panel with Secondary GFCI Shut-Off Box Using a

2-Pole GFCI Breaker with 2-Wire Grounded Connection

(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)

Main Panel*

Red (L2)

Black (L1)

GFCI Sub Panel*

2-Pole

GFCI

Breaker

TB1

R B

SPA CONROLLER

240 VAC

White (N)

Green (Ground)

*GFCI Sub Panel commonly used when recommended GFCI does not install in Main Panel.

Red (L2)

Black (L1)

Green

TB2

Ground/Bonding Lug**

Pigtail

Neutral Bus

Ground

No Load Neutral Wire

Note: service disconnect not shown in this diagram.

The control box TB1 terminal position varies between models.

advertisement