CSI MN15-S2, MN25-S2, TN25-S2 Installation And Operating Manual
CSI TN25-S2 is a fully automatic demand water softener designed to remove nitrate and sulfate from water. It has a maximum raw water nitrate/sulfate capacity of 25,000 mg/l and a maximum clear iron/manganese capacity of 2.5 ppm. The unit has a 13" x 54" mineral tank and an 18" x 33" brine tank. The service flow rate is 8.0 gpm and the backwash flow rate is 2.4 gpm. The unit uses 18 lbs of salt per regeneration and has a total grain capacity of 21,250. The CSI TN25-S2 is ideal for homes with high levels of nitrate and sulfate in their water supply.
Advertisement
Advertisement
SIGNATURE 2 SERIES
Signature 2 Series
Nitrate / Sulfate
Manual
Installation / Operation Manual
Fully Automatic & Demand
Water Softeners
SIGNATURE 2 SERIES
Specifications................................................................................................................Page 3
Installation.....................................................................................................................Page 4
Control Valve Set Up.....................................................................................................Page10
Utilizing Bluetooth.........................................................................................................Page 14
Control Valve Assembly...............................................................................................Page 15
Valve Body Assembly...................................................................................................Page 16
Valve Body Parts...........................................................................................................Page 17
Bypass Assembly..........................................................................................................Page 18
Additional Information..................................................................................................Page 19
Troubleshooting............................................................................................................Page 20
Error Codes....................................................................................................................Page 22
SIGNATURE 2 SERIES
Specifications
General Specifications
Grains Capacity / Regeneration
Salt Used / Regeneration
Maximum Raw Water Nitrate / Sulfate (mg/l)
Maximum Clear Iron / Manganese (ppm)
Exchange Resin (cu ft)
Mineral Tank (Vortech ™)
Brine Tank (polyethylene with grid & safety)
Service Flow Rate (gpm)*
Backwash Flow Rate ((gpm)
Gallons Used / Regeneration
Space Required
Approximate Shipping Weight (lbs)
TN15-S2
MN15-S2
15,000
18.0
100
0
1.5
10 x 54
18 x 33
5.0
1.2
60
18 x 28 x 62
133
TN25-S2
MN25-S2
25,000
30.0
100
0
2.5
13 x 54
18 x 33
8.0
2.4
80
18 x 31 x 62
251
WARNING
Lubricants
Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants will cause swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl®. It is recommended that
Dow Corning® silicone grease be used as a lubricant for all control valves. Dow Corning® 7 Release Compound is used in the manufacture of Chandler Systems control valves. (Part # LT-150)
Sealants
Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials. It is recommended that Teflon® tape be used to seal plastic Noryl® threaded fittings.
3
SIGNATURE 2 SERIES
Installation
Note: Due to the Nitrate System abilities to remove bi-carbonate (alkalinity) from the water, a dramatic reduction in pH of the treated water may be experienced. If this occurs, a whole house or upflow filter with neutralizer or Neu-Cor media may be required.
4
Installation
Installation Requirements
• A level floor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to
back-up of hot water.
• DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur!
(See Installation Diagrams for proper placement and plumbing connections.)
• A level floor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to
back-up of hot water.
• DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur!
(See Installation Diagrams for proper placement and plumbing connections.)
Nitrate Filter Location / Other Requirements
• Locate the unit near an unswitched, 120 volt / 60 Hz grounded electrical outlet.
• Check for distance and proper drain installation (e.g. floor drain, washing machine standpipe).
• Determine type and size of piping required for nitrate filter connection (e.g. copper, galvanized, PVC plastic).
Note: If household plumbing is galvanized and you intend to make the installation with copper (or vice versa), obtain di-electric unions to prevent dissimilar metal corrosion.
Note: Where the drain line is elevated above the control valve or exceeds 20 feet in length to reach the drain, use 3/4”
I.D. drain line tubing instead of 1/2” I.D. Drain line tubing is not included.
Caution: If sweat soldering copper pipe (remember to always use lead free solder and flux), cover yoke and bypass valve
with wet rags to prevent heat damage to connections and control valve! If using PVC or plastic pipe, primers and
solvent cements specifically recommended for use with potable water are required.
Note: All plumbing lines not requiring “soft” water should be connected “upstream” of the softener.
(See Typical Installation Diagrams)
Installation Procedure
Water Supply Connections and Bypass Valve
To allow for filter servicing, swimming pool filling or lawn sprinkling, a manual bypass valve has been installed at the factory.
The bypass allows water to be manually routed around the filter.
1. Position filter at desired location for installation. (See Installation Diagram.)
2. Turn OFF main water supply and OPEN nearest faucet to relieve pressure.
3. Cut main line and install appropriate elbows and extensions. Inlet and outlet connections on the control valve are
3/4” FNPT.
Note: An optional 1” FNPT is available.
Caution: Raised arrows located on the sides of control valve body and bypass valve indicate proper direction of water
flow. Install inlet and outlet piping in direction of arrows.
4. Rotate handle on bypass valve to the bypass position
5. Turn the main supply line on to restore water service to the home.
6. OPEN nearest faucet to evacuate air and repressurize plumbing lines.
7. Check for leaks!
5
SIGNATURE 2 SERIES
Installation
Drain Line Connection
1. Pull out clip and remove drain line assembly located on the left side of control valve. Remove drain line hose barb and
wrap threads with Teflon tape. Reinstall drain line hose barb. Caution: Hand tighten only!! Replace drain line assembly
and reinstall clip.
2. Install 1/2" I.D. drain line tubing (not included) from hose barb to an open drain. A 4” gap between the end of the drain
line and the open drain is required to prevent waste water backflow. Keep the drain line as short as possible. An
overhead drain line can be used if necessary, but should discharge below the control valve. A syphon trap (taped loop)
at the outlet of the drain line is advisable to keep the drain line full and assure correct flow during regeneration. Elbows
or other fittings must be kept at a bare minimum.
Note: Where the drain line is elevated above the control valve or exceeds 20’ in length, 3/4" I.D. drain line tubing should
be used.
Brine Line and Overflow Connection
1. Position brine tank on smooth, level surface near the nitrate filter resin tank. If necessary, the brine tank can be placed
at a higher level than the resin tank, but never at a lower level.
2. Install one end of 3/8” O.D. by 1/4" I.D. brine line tubing (included with unit) to compression fitting located on left side of
control valve.
3. Remove brine tank cover.
4. Remove cap from brine well.
5. Insert opposite end of brine line through outer hole in brine tank.
6. Connect brine line to push fitting on safety brine valve located inside brine well.
7. Install 1/2" I.D. drain line tubing (not included) to the overflow fitting on brine tank located just below the brine line.
8. Run the opposite end of brine tank drain line to a suitable drain.
Note: The brine tank drain line is gravity flow and must discharge below the overflow fitting.
Caution: Do not “TEE” to the main drain line from control valve.
Notice: The brine overflow is provided as a back-up in the event the safety float shut-off should fail, allowing the brine tank to overfill. This drain connection would then carry the excess water to the drain and prevent flooding of the floor. Therefore, no liability will or can be assumed by the manufacturer of the nitrate filter should this occur.
Electrical Connection
1. Connect the power supply to the control valve and plug into a 115 volt / 60 Hz receptacle.
Note: Do not plug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off.
Installing Battery Back-Up
1. Remove the valve cover.
2. Install a 9 volt battery.
Pressurizing The System
1.Slowly rotate handle of the bypass valve to the SERVICE position.
2.Open the nearest faucet to evacuate air from plumbing lines.
3. Check for leaks!
6
Installation
How To Calculate Regeneration Frequency
Note: The quantity of both nitrate and sulfate must be known for proper regeneration calculation.
Step 1: Convert Nitrate (NO3) and Sulfate (SO4) to Calcium Carbonate (CaCO3).
Nitrate Divide ppm (mg/l) of Nitrate by 62
NO
3
and multiply by 50.1
Example : (50 ppm NO3/62) x 50.1 = 40.4 ppm as CaCO3
Sulfate Divide ppm (mg/l) of Sulfate by 48
(SO
4
) and multiply by 50.1
Example : (75 ppm SO4/48) x 50.1 = 78.28 ppm as CaCo3
Step 2: Calculate the Nitrate / Sulfate ration (as CaCO3).
NO
NO
3
(Nitrate) = Ratio
3
(Nitrate) + SO4 (Sulfate)
Example : 40.4 ppm = .34 Ratio
40.4 ppm + 78.28 ppm
Step 3: Calculate the operating capacity per cubic foot of resin at 12 lbs. per cubic foot salting (factory setting).
Figure 3 OPERATING CAPACITY
Note: DO NOT REDUCE SALT BELOW THIS LEVEL!
Operating Capacity = 8,500 grain / cu. ft. of media
7
SIGNATURE 2 SERIES
Installation
Step 4: Calculate the grains capacity for the system being installed.
Example : MN15 = 1.5 cu. ft. x 8,500 grains / cu. ft.
= total capacity
Step 5: Calculate total grains of nitrate.
NO
3
ppm as CaCO
17.1
3
= grains of Nitrate
Example: 40.4 ppm NO
3
as CaCO
3
17.1
= 2.36 grains (or 3 grains)
Step 6: Enter meter programming mode and set system capacity (items) to answer in step 4.
Example: capacity
Step 7: Program the Signature Series Control Valve for grains of nitrate calculated in step 5.
Example: 3 grains (always round the number up)
- Control Valve Operation -
1. Advance control valve to BACKWASH (cycle 1) position and allow water to run to drain for 3 to 4 minutes.
Warning : Close valve on bypass prior to selecting the backwash position. After backwash position has been
established, slightly open bypass to evacuate air from the media tank. Fully open valve when all air
is depleted. This procedure will prevent media from being uplifted into control valve.
2. Advance control valve to BRINE REFILL (cycle 4) position and allow the brine tank to fill just over the salt grid plate.
3. Advance control valve to BRINE & RINSE (cycle 2) and allow the control valve to draw water from the brine tank until it
stops. If no draw is observed, check tightness of brine line compression fittings.
4. Advance control valve to RAPID RINSE (cycle 3) position and let run to drain for 3 - 4 minutes.
5. Advance control valve to BRINE TANK REFILL (cycle 4) position and allow the control valve to automatically fill the
brine tank.
Note : Control valve will advance to service position automatically.
8
Installation
Filling The Brine Tank With Salt
To expect a high level of performance and reliability, a salt manufactured specifically for water softeners must be used.
Salt of this grade is virtually free from dirt and other particulate that would eventually cause the nitrate filter to malfunction.
A pellet type salt is recommended, although any high quality water softener salt (such as solar salt) will suffice. The salt level will decrease after each regeneration cycle. Consequently, the brine tank will need to be checked and replenished periodically.
1. Fill the brine tank with water softener salt as described above. This will be approximately 250 pounds of salt.
Warning: Do not fill above level of the brine well.
2. Replace brine tank lid.
Final Check
1. Be certain the bypass valve is in the SERVICE position.
2. Make sure the power supply is connected to an uninterrupted 115 volt outlet.
3. Check that the time of day is set.
4. Double check regeneration schedule.
5. Make final check for leaks!
6. Fill out and mail warranty card.
7. Leave all manuals with unit.
Operation, Care and Cleaning
When the inlet/outlet knobs on the bypass valve are in the SERVICE position (position of bypass knobs are parallel to the inlet/outlet piping), water is directed through the nitrate filter. Water may be bypassed by turning the inlet/outlet knobs to the bypass position (position of bypass knobs are at right angles to inlet/outlet piping). Water to the home will bypass the nitrate filter and be untreated.
You should manually bypass the nitrate filter if:
1. The outside lines do not bypass the nitrate filter and water is to be used for lawn sprinkling or other similar uses.
2. Servicing the nitrate filter.
3. A water leak from the nitrate filter is evident.
4. Shock treating water well and piping with chlorine or other disinfectant.
Extra Regeneration
If soft water demands are usually heavy, an extra regeneration can be initiated manually:
To Skip A Regeneration
1. For vacations, or extended periods of absence, the power supply can be disconnected from the control valve.
2. Upon return, plug in cord and reset the time of day, if 9 volt battery was not installed. If battery was installed, replace
battery.
9
SIGNATURE 2 SERIES
Control Valve Start Up
- Programming The Control Valve For “MS” Units -
1. Set time of day.
2. Set a.m. or p.m.
3. Set water hardness in grains per gallon (gpg).
Note : If the water contains iron and / or manganese, multiply the total parts per million (ppm) by “four” (4) and then add to the grains per gallon (gpg) of hardness. Use this COMPENSATED HARDNESS level when programming the regeneration frequency.
1. Set regeneration day override if other than (7) days is desired. (This is particularly useful when iron is being treated to
prevent fouling of the resin.)
2. Set regeneration time, if other than 2:00 a.m. is desired.
Note : Salt settings are pre-set at the factory for the maximum shown on the capacity charts.
Warning : Do not reduce salt settings below 9 lbs. as the water level in the brine tank will not reach the grid plate.
10
SIGNATURE 2 SERIES
Control Valve Start Up
Main Menu
12 : 00
1. To enter Main Menu, press the Menu/Enter button.
(Time of Day will flash)
4.
3.
2.
(First
To set the Time of Day , press the Set/Change button.
-
-
-
-
To change digit value, press the Set/Change button.
To accept the digit value, press the Menu/Enter button.
Next digit will flash to begin setting.
Once the last digit display is accepted, all digits will flash.
-
-
To set A.M.
or P.M
., press the Menu/Enter button.
- To change digit value, press the Set/Change button.
To accept the digit value, press the Menu/Enter button.
Once A.M. or P.M. is accepted, the next menu item will flash.
a. To set the
Softeners
-
)
Number of Days between Regeneration
Repeat instructions from step (2).
Notes: 1) Maximum value is 29.
(A), press the
2) If value set to 0, Regeneration will never occur.
3) Default setting is 4 days for softeners.
Example [
Set/Change
A ]
button. (
Example [ A - 07 ] b. To set Hardness ( Metered Softeners Only ) an “H” will appear to enter Compensated
Hardness in grains per gallon (gpg) Default setting is 25 gpg. Example [ H - 25 ]
Time Clock
5. To Exit Main Menu, press the Menu/Enter button.
Note: If no buttons are pressed for 60 seconds, the Main Menu will be exited automatically.
11
SIGNATURE 2 SERIES
Control Valve Start Up
Normal Operation
2.
1.
1. Home Display a. Time Clock Softeners Alternates between the display of Time of Day and Number of Days until the Next
Regeneration.
- Days Remaining until the Next Regeneration will count down from the entered value until it reaches
1 day remaining.
b.
- A Regeneration Cycle will then be initiated at the next designated regeneration time.
Metered models alternate the Time of Day and Gallons left until the next regeneration. The meter will count
down to zero (0000) and then regenerate at the scheduled time set.
2. Battery Back-Up (Uses a standard 9-volt alkaline battery.)
Features of Battery Back-Up:
• During power failures, the battery will maintain the time of day as long as the battery has power. The
display is turned off to conserve battery power during this time. To confirm that the battery is working,
press either button and the display will turn on for five (5) seconds.
• If power failure occurs while system is regenerating, the Signature 2 will motor to a shut off position
to prevent constant flow to drain. Depending upon system pressure and other factors, it is possible to
observe a reduced flow to drain during this step. After power is restored, the Signature 2 will return
and finish the cycle where it left off prior to the power interruption.
• When used without battery back-up, during a power failure, the unit stops at its current point in the
regeneration position and then restarts at that point when the power is restored. The time will be
offset by the increment of time the unit was without power, so it is necessary to reset the time of day
on the unit. No other system will be affected.
Starting Extra Regeneration Cycle
To Start Delayed Extra Cycle Example
-
-
If Days Remaining Until Next Regeneration does not read ‘1’, press and hold the Set/Change button for 3 seconds until the display reads ‘1’, or ‘0000’ on metered models.
Regeneration cycle will initiate at the next designated regeneration time.
-
-
To start Immediate Extra Cycle First complete above step.
- With Days Remaining Until Next Regeneration at ‘1’ or ‘0000’,
Press and hold the Set/Change button.
After 3 seconds, the regeneration cycle will begin.
3. To thru regeneration First complete above 2 steps.
Note : Press and hold the Set/Change button for 3 seconds to advance to the next cycle step. Fast Cycle is not
necessary unless desired to manually step through each cycle step. (Repeat until valve returns to the home
display)
Softeners
Step 1
Step 2
Step 3
Step 4
Default (Min)
Backwash 10
Brine & Rinse
Rapid Rinse
Brine Refill
60
10
9 lbs/ cu ft
12
SIGNATURE 2 SERIES
Control Valve Start Up
Master Programming Mode
To enter Master Programming Mode, press and hold both buttons for 5 seconds.
Note: All Master Programming functions have been preset at the factory. Unless a change is desired, it is NOT necessary to enter Master Programming Mode.
1. Regeneration Time ( r ) [
- The time of day at which regeneration may take place is designated by the letter “ r ”.
- Default regeneration time setting for
- Press Menu/Enter
- Change the digits with the
SOFTENERS is 2a
- The first display digit indicates A.M. or P.M. To change the value, press the
button to accept the value and move to the next digit.
- The second and third display digits indicate the hour at which the regeneration will occur.
Set/Change button and accept with the
- After the entire display flashes, press the Menu/Enter
Set/Change
Menu/Enter button.
button.
button to move to the next menu item.
2. Regeneration Day Override (A) – Meter (Demand) Mode Only
- Press Menu/Enter button. This display is used to set the maximum amount of time (in days) the unit can be in
service without regeneration. This setting is identified by the letter “A” in the left digit. Regeneration will begin at
the scheduled time. A setting of zero will cancel this feature.
- Example: Override every 7 days ( A-07 ), default setting, or cancel setting ( A-00 ). Maximum is 29.
3. Regeneration Cycle Step Times (Steps 1, 2, 3, 4)
Example ]
- The next 4 displays set the duration of time in minutes for each regeneration cycle step.
- The step number which is currently modifiable is indicated on the far left of the display screen.
- The number of minutes allotted for the selected backwash step is displayed on the far right.
- Change the digit values using the Set/Change and Menu/Enter buttons as described above.
4. System Capacity in Grains ( c ) – Meter (Demand Mode Only)
- Press the Menu/Enter button. This display is used to set the system capacity in grains and is used in
conjunction with the hardness setting to calculate total gallons of treated water available between regenerations.
This option is identified by the letter “c” in the left digit. The maximum value for this item is 399. Example: 32,000
grain capacity ( c 032 ).
5. Reserve Capacity Setting % ( p - 25 )
6. Bluetooth Enabled BE - 1 (ON)
BE - 0 (OFF)
7. Bluetooth Password BBPP is displayed for one second, then password is displayed.
8. To Exit the Master Programming Mode, press the Menu/Enter button until time of day returns.
Note : If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically.
13
SIGNATURE 2 SERIES
Utilizing Bluetooth Control
To take advantage of the Bluetooth interface this feature must be set up on a compatible Bluetooth enabled smart phones or tablets.
Note: Valves with a revision number greater or equal to “C2.00” are only compatible with Bluetooth 4.0+ (a.k.a.
Bluetooth LE) Smartphones and tablets. If you have an Android or Apple device with a compatible Bluetooth radio it can be used to connect to the valve. Valves with a revision number less than “C2.00” are only compatible with Android devices and these valves use a Bluetooth 2.0 radio. In the rest of this section valves with a revision number greater or equal to “C2.00” will be referred to as BTLE, valves with a revision number less than “C2.00” will be referred to as BT.
(The firmware revision of the valve can be viewed on the valve display for 2 seconds after the valve is powered up.)
Unfortunately due to changing Bluetooth and Tablet / Phone manufacturing standards, not all tablets and smart phones are compatible with all valve versions. In general, the below table should guide you in compatibility.
Android Device with BT 4.0+
Android Device with older BT
Apple Device with BT 4.0+
BT Legacy View Valve
Yes
Yes
No
BTLE Legacy View Valve
Yes
No
Yes
1. Download and install the Legacy View app from the Google Play Store, Apple App Store or
www.ChandlerSystemsInc.com
2. If your valve revision is a BTLE valve you can skip this step. Otherwise, if it is a BT valve the following steps must be followed to pair your smart phone or tablet to the control valve.
• Open the settings menu on your smart phone or tablet and click on Bluetooth.
• Look for the softener or filter valve you want to connect to under the list of available Bluetooth devices.
• Select the device and pair (Default password is: 1234)
3. Open the Legacy View app
• Choose a valve device at any time from the list of available devices to connect to by clicking on it.
• If the valve you want to connect to doesn’t show up, or there is a problem connecting to a device you can
press the “Scan for Devices” button or the Legacy View logo at any time to refresh the list and start the
process over.
• If the valve device is a BTLE valve and it has a password other than the default password, the first time you
connect to it the app will ask you to enter the password. After entering it the first time you should not need to
enter it again unless it changes.
4. BTLE Valve devices can be updated by the App. When the app is updated from the Google Play Store or the
Apple App Store, it may contain an updated firmware program for the valve devices. These updates could contain new features or operational improvements. It is up to the user to allow these updates to be sent to the valve device.
Uploading a new program takes approximately 1 minute.
FCC ID:
Name of Grantee:
SWPLV-019 or SWPEV-019-BLE
CHANDLER SYSTEMS, INC.
Equipment Class:
Notes:
Part 15 Low Power Communication Device
Legacy
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
14
SIGNATURE 2 SERIES
Control Valve Assembly
1
4 6
5
F
P
M
E
E
3
13
P
16
8
19
18
7
15
12
9
M
17
LETTERS IN DIAGRAM REPRESENT WIRING CONNECTIONS
* "F" Port is for softener flow meter connection (flow meter not shown)
14
10
11
12
13
14
9
10
11
15
16
17
21
4
5
6
7
8
1
2
3
Ref
0
0
Description
Timered Power Head Assy.
Metered Power Head Assy.
Softener Circuit Boad Assy.
Encoder
Front Plate
Encoder Wheel
Main Gear
Power Supply
Back Plate
Lower Front Base For Cover
Motor
Lower Back Base for Cover
Valve Cover
Piston Screw
Screw
Screw
Piston Washer
Washer Circuit Board
Screw Motor
Valve Hex Screw
1
3
3
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
Qty
1
1
Part Number
21001X100
21003X100
21001X102
20001X124
20001X004
20001X007
20001X120
20001X125
20001X005
20111X002
20016X006
20111X003
20111X000
20001X003
SC10
SC9
20001X002
20111X014
SC2
20001X001
15
SIGNATURE 2 SERIES
Valve Body Assy. (Softener Version)
2
1
10
11
13
14
12
15
16
17
18
9
4
3
5
6
7
8
6A
23
20
19
17
22
21
24
16
SIGNATURE 2 SERIES
Valve Body Assy. Parts List(Softener Version)
Ref
#
Description
1 Piston Assembly
Part # Qty.
2 10-24 x 13/16 Screw
3 Seal & Spacer Kit
4 End Spacer
5 Flow Control Button 1.5 GPM
Flow Control Button 2.0 GPM
Flow Control Button 2.4 GPM
Flow Control Button 3.0 GPM
Flow Control Button 3.5 GPM
Flow Control Button 4.0 GPM
20001X231
20001X226
20561X253
N/S
20251X266
20251X267
20251X268
20251X269
20251X270
20251X271
Flow Control Button 5.0 GPM
Flow Control Button 7.0 GPM
20251X272
20251X274
1
1
6 Plastic Flow Control Housing
Flow Control Assy. 1.5 GPM-
PVC
20251X100 1
6a Flow Control Assembly – Specify GPM Incl. (1) each #20 thru #23
20251X256 1
20251X257 1 Flow Control Assy. 2.0 GPM-
PVC
Flow Control Assy. 2.4 GPM-
PVC
20251X258
1
1
1
1
1
1
1
1
1
3
20251X259 1 Flow Control Assy. 3.0 GPM-
PVC
Flow Control Assy. 3.5 GPM-
PVC
Flow Control Assy. 5.0 GPM-
PVC
Flow Control Assy. 7.0 GPM-
PVC
7 Drain Line Fitting 90º Elbow
1/2” NPT X 1/2” Tubing
8 Drain Retainer
9 Brine Assembly
10 BLFC Assembly .5 GPM
20251X260
20251X262
20251X264
20251X255
20001X214
20561X225
20001X228
1
1
1
1
1
1
1
N/S indicates non-stocked item
Shaded Ref # indicates assembly or kit
Ref
#
Description
11 Brine Line Ferrule
Part # Qty.
12 Brine Line Compression Nut
13 10-24 X 1 Hex Screw
14 Injector Cap
14a Injectory Kit-Specify Size- Inc.
(1) ea #14, #15, #16, #17 & (2)
#13
15
16
17
Injector Seal
Injector Assy. Specify Size
Injector Screen
20251X305
N/S
20001X226
20001X223
20001X220
20001X224
20001X219
20001X222
18 Injector Plug & O-Ring Assy.
19 O-Ring
20 O-Ring 20561X204 1
Items #21 thru #24 used ONLY with clock regeneration
21 Mounting Clip 20561X201 2
22 8-18 X 5/8” Screw
23 Adapter Coupling
20001X217
2000X215
20561X217
N/S
20561X215
1
1
23a Adapter Coupling & O Ring
Assy. Incl. (1) #40 & (2) # 41
24 O-Ring 20561X216
2
2
1
4
1
1
1
1
1
1
1
1
17
SIGNATURE 2 SERIES
Bypass Assembly
(1A)
18
(2)
(1)
Ref #
1A
1
2
Description
Meter Assembly, Turbine Complete
Plastic Bypass Valve Assembly
Bypass Valve 3/4” Stainless Steel
Bypass Valve 1” Stainless Steel
Part #
20003X200
20561X292
20561X270
20561X283
Qty
1
1
1
1
Service Instructions / Instructional Videos Available at www.csiwater.com
A.
B.
General Preliminary Instructions
PERFORM BEFORE ALL SERVICING OPERATIONS
1. Turn off water supply to conditioner.
-If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then
close the valves at the conditioner inlet and outlet.
-If the conditioner has an integral bypass valve, put it in the bypass position.
-If there is only a shut off valve near the conditioner inlet, close it.
2. Remove cover and relieve water pressure in the conditioner by stepping the control into the backwash
position momentarily. Return the control to the service position.
3. Unplug electrical cord from outlet.
To Replace Injectors & Screen
1. Follow steps A1 - A3 (above)
2. Remove injector cap screws and remove cap.
3. Remove injector assembly. Apply silicone lubricant to new injector assembly O rings and install. Be sure to
push injector assembly tightly so O rings are seated. Install a new screen.
4. Apply silicone lubricant to new gasket and install on injector cap.
5. Follow D7 - D14.
C. To Replace Powerhead
1. Remove the control valve cover and disconnect the power supply.
2. Disconnect the meter cable from circuit board and feed back through control (if existing meter is being re-used)
3. Remove screw and washer at drive yoke. Remove powerhead mounting screws. The entire powerhead
assembly will now lift off easily.
4. Put new powerhead on top of the valve. Be sure the drive pin on main gear engages slot in drive yoke (wide
side of drive yoke upright must face to the left away from the motor).
5. Replace powerhead mounting screws. Replace screw and washer at drive yoke.
6. Reconnect meter signal, optical sensor, power supply, and circuit board signal wires.
7. Reinstall cover.
D.
To Replace Brine Valve
1 . Follow steps A1 - A3
2. Remove the control valve cover. Disconnect the meter cable from the meter assembly.
3. Remove screw and washer at piston drive yoke. Remove powerhead mounting screws. The entire powerhead
assembly will now lift off easily.
4. Remove piston retaining plate screws and pull upward on end of piston yoke until assembly is out of valve.
5. Pull brine valve from valve body.
6. Apply silicone lubricant to O ring on new brine valve assembly and press into brine valve hole, shoulder on
bushing should be flush with injector body.
7. Reinstall piston and powerhead assembly.
8. Reconnect brine tube and drain line.
9. Return bypass or inlet valving to normal service position. Water pressure should now be applied to the
conditioner, and any bypass line shut off.
10. Check for leaks at all seal areas. Check drain seal with the control in the backwash position.
11. Plug electrical cord into outlet.
12. Set time of day and cycle control valve manually to assure proper function. Make sure control valve is
returned to the service position.
13. Make sure there is enough salt in the brine tank.
14. Start regeneration cycle manually if water is hard.
15. Replace control valve cover.
19
SIGNATURE 2 SERIES
Service Instructions / Instructional Videos Available at www.csiwater.com
G.
E. To Replace Piston Assembly
1. Follow steps A1 - A3
2. Remove control valve back cover. Disconnect the meter signal wire from the meter.
3. Remove screw and washer at piston drive yoke. Remove powerhead mounting screws. The entire powerhead
assembly will now lift off easily.
4. Remove piston retaining plate screws.
5. Pull upward on end of piston yoke until assembly is out of valve.
6. Inspect the inside of the valve to make sure that all spacers and seals are in place, and that there is no foreign
matter that would interfere with the valve operation.
7. Take new piston assembly and push piston into valve by means of the end plug. Twist drive yoke carefully in a
clockwise direction to properly align it with drive gear. Reinstall piston retaining plate screws.
8. Place powerhead on top of valve. Be sure drive pin on main gear engages slot in drive yoke (wide side of drive
yoke upright must face to the left away from the motor).
9. Replace powerhead mounting screws. Replace screw and washer at drive yoke.
10. Follow steps D9 - D14.
F. To Replace Seals and Spacers
1. Follow steps A1 - A3 .
2. Remove the control valve cover. Disconnect the meter signal wire from the meter.
3. Remove screw and washer at piston drive yoke. Remove powerhead mounting screws. The entire powerhead
assembly will now lift off easily. Remove piston retaining plate screws.
4. Pull upward on end of piston rod yoke until assembly is out of valve. Remove seals and spacers. (Note: Special
end spacer must be reused)
5. Lubricate new seals with silicone lubricant included in the seal and spacer kit. Make sure the special end
spacer is properly seated in the valve body. Install new seals and spacers individually, pressing around the
outer edge of each seal to make sure it is seated. (When all seals and spacers are seated properly, you will
have a 1/4” of space between the top seal the the top of the valve body)
6. Follow Steps E7 - E10 .
To Replace Meter
1. Follow steps A1 - A3
2. Remove two screws and clips at bypass valve or yoke. Pull softener tank away from plumbing connections.
3. Remove meter cable from meter.
4. Remove two screws and clips at meter and pull the meter out of the control valve.
5. Apply silicone lubricant to O rings on new meter.
6. Attach meter to control valve. Note: meter portion of module must be assembled on valve outlet. Install two
screws and clips.
7. Plug meter cable into new meter.
8. Attach two clips and screws at bypass valve or yoke. Be sure clip legs are firmly engaged with lugs.
9. Follow steps D9 - D14.
20
SIGNATURE 2 SERIES
Troubleshooting Guide
SYMPTOM
1.Softener Fails to
Regenerate
Automatically
2. Regeneration at
Wrong Time
3. Loss of Capacity
4. Poor Water Quality
5. High Salt Usage
6. Loss of Water Pressure
PROBABLE CAUSE
Power supply plugged into intermittentent or dead power source
Disconnected meter cable
CORRECTION
Connect to constant power source
Improper control valve programming
Defective power supply
Meter is dirty or defective
Defective Drive motor
Reconnect cable
Reset program settings
Replace power supply
Clean or replace meter assembly
Replace motor
Time of day improperly set, due to power failure
Regeneration time set improperly
Increased raw water hardness
Reset time of day programming and install 9-volt battery.
Reset regeneration time programming
Increase hardness setting or decrease days between regeneration
Brine concentration and or / quantity Keep brine tank full of salt at all times.
Clean it yearly. Salt may be bridged.
If using a salt grid plate, ensure refill water is over it.
Resin fouling Call dealer. Find out how to confirm it. Clean the resin and prevent future fouling.
Poor distribution, channeling (uneven bed surface)
Internal valve leak
Resin age
Resin loss
Call dealer. Check backwash flow.
Regenerate more frequently
Call dealer. Replace spacers, seals and / or piston
Call dealer. Check for resin oxidation caused by chlorine. Mushy resin.
Call dealer. Check for correct bed depth. Broken distributor tube. Air or gas in bed: well gas eliminator. Loose brine line.
Check items listed in #1, #2, and #3
Bypass valve open
Channeling
High salt setting
Excessive water in brine tank
Constant flow through the unit
Regenerating too frequently
Scaling / fouling of inlet pipe
Fouled resin
Improper backwash setting
Close bypass valve.
Check for too slow or high service flow. Check for media fouling.
Lower brine tank refill time
See symptom #7
Indicates plumbing leak (e.g. toilet tank)
Lower hardness setting or increase days between regeneration.
Clean or replace pipline. Pretreat to prevent.
Clean resin. Pretreat to prevent.
Backwash more frequently
21
SIGNATURE 2 SERIES
Troubleshooting Guide
8. Softener Fails to Use
Salt
9. Continuous Flow to
Drain
SYMPTOM
7. Excessive Water in
Brine Tank and / or
Salty Water to Service
PROBABLE CAUSE CORRECTION
Plugged drain line or drain line control Check flow to drain. Clean drainline flow control button
Dirty or damaged brine valve Clean or replace brine valve.
Plugged injector or screen
Low inlet pressure
Excessive brine refill cycle time
Plugged / restrict drain line
Injector and / or screen is plugged
No water in brine tank
Clean or replace injector screen.
Increase pressure to allow injector to perform properly. (20 psig minimum)
Lower brine refill time.
Check items listed in #1
Improper control valve programming Check and reset programming
Clean drain line and / or flow control button
Clean or replace injector and screen
Water pressure is too low
Check for restriction in BLFC. Ensure safety float is not stuck. Check brine tank for leaks.
Line pressure must be at least 20 psi.
Brine line injects air during brine draw Check brine line connectionsfor air leaks
Internal control leak Call dealer. Check piston, seals and spacers for scratches and dents.
Foreign material in control piston and seals
Internal control leak
Valve jammed in backwash, brine or rapid rinse position
Motor stopped or jammed
Call dealer. Clean valve and replace piston and seals.
Same as above.
Same as above.
Check for jammed piston. Replace piston and seals. Replace motor if motor is unresponsive.
Error Codes
There are five (5) error codes which could indicate a possible problem with the control valve:
Error 2 Valve is searching for homing slot.
Allow valve to run until homing slot is found or new error code appears.
Error 3 No encoder slots are being seen.
Check encoder connection. If encoder is connected. Check valve body for debris
and replace seals. Inspect piston and replace if worn.
Error 4 Unable to find homing slot.
Check encoder wheel for debris.
Error 5 Motor overload.
Check valve body for debris. Replace seals. Inspect piston and replace if worn.
Check motor operation and replace motor if unresponsive.
Error 6 - No power to motor. Check motor connections, replace motor if unresponsive.
22
SIGNATURE 2 SERIES
WATER TREATMENT EQUIPMENT
This warranty cannot be transferred - it is extended only to the original purchaser or first user of the product. by accepting and keeping this product, you agree to all of the warranty terms and limitations of liability described below.
Important Warning: Read carefully the CSI Water Treatment Systems
Equipment Installation, Operating and Maintenance Instructions Manual to avoid serious personal injury and property HAZARDS and to ensure safe and proper care of this product.
Model Numbers Covered:
Water Softeners, Media Filters and Upflow Filters
*FOR AS LONG AS YOU OWN AND LIVE IN YOUR SINGLE FAMILY
HOME, this warranty covers your water treatment equipment, if you are the first user of this CSI Water Treatment Systems equipment and purchased it for single family home use - subject to all of the conditions, limitations and exclusions listed below. Purchasers who buy the CSI Water
Treatment Systems equipment for other purposes, and other component parts are subject to more limited warranties and you should read all of the terms included in this form to make sure you understand your warranty.
What is covered by this warranty?
CSI Water Treatment Systems warrants that at the time of manufacture, the water treatment equipment shall be free from defects in material and workmanship as follows :
Product
Residential Mineral Tank
Proprietary Control Valves
Other Softener / Filter Control Valves
Brine Tank
Residential Reverse Osmosis System
Other Accessoreis and Parts
Brine Tank Compoents
REVERE Wireless Low Salt Alarm
Warranty
10 Years
7 Years
5 Years
5 Years
5 Years
1 Year
1 Year
90 Days
* This warranty does not include media and/or cartridge filter elements.
Additional Terms & Conditions
What CSI Water Treatment Systems will do if you have a covered warranty claim CSI will at its option either make repairs to correct any defect in material or workmanship or supply and ship either new or used replacement parts or products. CSI will not accept any claims for labor or other costs.
Additional Exclusions and Limitations
This warranty is non-transferable and does not cover any failure or problem unless it was caused solely by a defect in material or workmanship.
In addition, this warranty shall not apply :
• If the water treatment equipment is not correctly installed, operated, repaired and maintained as described in the Installation, Operating &
Maintenance Instructions Manual provided with the product.
• Defects caused as a direct result of the incoming water quality
• If the tank is not the size indicated for the supply line size of the installation, as described in the manual.
• To any failure or malfunction resulting from abuse (including freezing), improper or negligent; handling, shipping ( by anyone
• If the unit has not always been operated within the factory calibrated temperature limits, and at a water pressure not exceeding 125 psi other than CSI), storage, use, operation, accident; or alteration, lightning, flooding or other environmental conditions;
• To any failure or malfunction resulting from failure to keep the unit full of potable water, free to circulate at all times; and with the tank free of damaging water sediment or scale deposits;
• This warranty does not cover labor costs, shipping charges, service charges, delivery expenses, property damage, administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment.
• The warranty does not cover any claims submitted to CSI more than
30 days after expiration of the applicable warranty, and does not apply unless prompt notice of any claim is given to an authorized CSI
Dealer or to CSI or a designated contractor is provided access to the installation and to the water treatment equipment.
THESE WARRANTIES ARE GIVEN IN LIEU OF ALL OTHER EXPRESS
WARRANTIES. NO CSI REPRESENTATIVE OR ANY OTHER PARTY
IS AUTHORIZED TO MAKE ANY WARRANTY OTHER THAN THOSE
EXPRESSLY CONTAINED IN THIS WARRANTY AGREEMENT.
Additional Warranty Limitations
ANY IMPLIED WARRANTIES THE PURCHASER MAY HAVE, IN-
CLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BE-
YOND THE APPLICABLE TIME PERIODS SPECIFIED ABOVE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
Limitations of Remedies
The remedies contained in this warranty are the purchaser’s exclusive remedies. In no circumstances will CSI or the seller of the product be liable for more than, and purchaser-user’s remedies shall not exceed, the price paid for the product. In no case shall CSI or seller be liable for any special, incidental, contingent or consequential damages. Special, incidental, contingent and consequential damages for which CSI is not liable include, but are not limited to, inconvenience, loss or damage to property, consequential mold damage, loss of profits, loss of savings or revenue, loss of use of the products or any associated equipment, facilities, buildings or services, downtime, and the claims of third parties including customers. Some states do not allow the exclusion or the limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you.
What to do if you have a problem covered by this warranty
Any warranty coverage must be authorized by CSI. Contact the person from whom you purchased the product, who must receive authorization from a CSI Dealer .
If your product is new and not used and you wish to return it, contact your
CSI Dealer.
SIGNATURE 2 SERIES
CSI WATER TREATMENT SYSTEMS
710 Orange St, Ashland, OH 44805 l PH 419-281-6829 l FAX 419-281-2375
www.csiwater.com
Advertisement