Operator's
Manual aero / SQ
Wet/Dry
Vacuum
READ THIS BOOK
This book has important information for the use and safe operation of this machine. Failure to read this book prior to operating or attempting any service or maintenance procedure to your ALTO machine could result in injury to you or to other personnel; damage to the machine or to other property could occur as well. You must have training in the operation of this machine before using it. If your operator(s) cannot read English, have this manual explained fully before attempting to operate this machine.
All directions given in this book are as seen from the operator’s position at the rear of the machine.
For new books write to: ALTO U.S. Inc., 2100 Highway 265, Springdale, Arkansas 72764.
Form No. 70204A 3/00 WAP TECHNOLOGY Printed in the U.S.A.
Table of Contents
Important Safety Instructions .................................................................................... 3
Specifications and Accessories .............................................................................. 5
Grounding Instructions ............................................................................................. 6
How To Assemble the Machine ................................................................................ 7
How To Prepare The Machine For Operation ........................................................... 7
Machine Operation .................................................................................................. 8
Maintenance and Repair ......................................................................................... 9
Troubleshooting....................................................................................................... 10
Section II Parts and Service Manual
Assembly Drawing for aero 5 Gallon and aero 7 AS/E ............................................ 12
Parts List ....................................................................................................... 13
Assembly Drawing for SQ 10 and 15 Gallon ............................................................ 14
Parts List ....................................................................................................... 15
Assembly Drawing for SQ 17 Gallon ....................................................................... 16
Parts List ....................................................................................................... 17
Page -2 WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
WARNING
IMPORTANT SAFETY INSTRUCTIONS
AVERTISSEMENT ADVERTENCIA
DANGER:
WARNING:
CAUTION:
Failure to read and observe all DANGER statements could result in severe bodily injury or death. Read and observe all DANGER statements found in your Owner's Manual and on your machine.
Failure to read and observe all WARNING statements could result in injury to you or to other personnel; property damage could occur as well. Read and observe all WARNING statements found in your Owner's Manual and on your machine.
Failure to read and observe all CAUTION statements could result in damage to the machine or to other property. Read and observe all CAUTION statements found in your Owner's Manual and on your machine.
WARNING:
To reduce the risk of fire, electric shock, or injury:
1. Do not leave machine when plugged in. Unplug from outlet when not in use and before servicing.
2. To reduce the risk of electric shock use indoors only.
3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
4. Use only as described in the manual. Use only manufacturer's recommended atattachments.
5. Do not use with damaged cord or plug. If machine is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run machine over cord. Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
8. Do not handle plug or machine with wet hands.
9. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair and anything that may reduce air flow.
10. Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
11. The following materials must not be picked up with the machine: Hot materials
(glowing cigarettes, hot ashes, etc.); Inflammable, explosive or aggressive fluids (e.g.
gasoline, solvents, acids, alkalines, etc.); Inflammable, explosive dusts (e.g.
magnesium or aluminum dust, etc.).
12. Do not use without dust bag and/or filters in place. Use the machine only with an undamaged filter element.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
16. Connect to properly grounded outlet. See "Grounding Instructions".
SAVE THESE INSTRUCTIONS
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual Page -3-
DANGER:
DANGER:
WARNING:
WARNING:
CAUTION:
CAUTION:
CAUTION:
CAUTION:
CAUTION:
Failure to read the Owner's Manual prior to operating or attempting any service or maintenance procedure to your Wap Technology machine could result in injury to you or to other personnel; damage to the machine or to other property could occur as well. You must have training in the operation of this machine before using it. If your operator(s) cannot read English, have this manual explained fully before attempting to operate this machine.
Operating a machine that is not completely or fully assembled could result in injury or property damage. Do not operate this machine until it is completely assembled. Inspect the machine carefully before operation. Use only as described in this manual. Use only Wap Technology's recommended attachments and replacement parts.
Operating a machine without observing all labels, decals, etc., could result in injury or damage. Read all machine labels before attempting to operate the machine. Make sure all of the labels are attached or fastened to the machine.
Get replacement labels and decals from your Wap Technology distributor.
Before connecting any appliance to the appliance plug socket, the machine must always be switched off. If appliances are connected to the appliance plug socket, ensure that these appliances are also switched off when being connected to the appliance plug socket. See "Appliance Plug Socket" in the
"Grounding Instructions" section in of this manual.
Making technical modifications to the machine could endanger your safety. Do not make any technical modifications to the machine.
Never spray the top section of the machine with water. Can cause danger to persons or danger of short circuits.
Wrap cord around handle when machine is not in use. Use caution not to run over cord while machine is in use.
This machine is not suitable for picking up health endangering dust.
If foam/liquid comes out, switch off immediately.
Page -4 WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
SPECIFICATIONS & ACCESSORIES
Model SQ 10 Gal.
Voltage
Frequency
Power
Connected load for appliance plug socket
Volume Flow (air)
Static Water Lift
Filter Surface Area
Sound Level
Cord Length
Tank Volume
Width
Depth
Height
Weight
Order # for bag-type filter elements
(pack of 5 elements)
Order # for filter element
H.E.P.A. Filter
Clothe Filter Liner /
Washable
Filter Element Cover
Squeegee Floor Tool
Replacement
Squeegee Blades
120 V
60 Hz
1200 Watts
600 Watts
120 CFM
90"
3.5 sq. ft.
58 db(A)
22'
10 gal.
18"
17"
20"
26 lbs.
29739
29747
40181
17081
11801
5149
6114
(set of 2)
NA = Not available
SQ 15 Gal.
120 V
60 Hz
1200 Watts
600 Watts
120 CFM
90"
3.5 sq. ft.
58 db(A)
22'
15 gal.
17"
17"
26"
33 lbs.
14895
29747
40181
17081
11801
5149
6114
(set of 2)
SQ 17 Gal.
120 V
60 Hz
1200 Watts
600 Watts
120 CFM
90"
3.5 sq. ft.
58 db(A)
22'
17 gal.
23"
22"
37"
55 lbs.
47429
29747
40181
8726
11801
5149
6114
(set of 2)
11753
40181
NA
NA
60908
NA aero 5 Gal.
120 V
60 Hz
1200 Watts
NA
120 CFM
65"
3.5 sq. ft.
62 db(A)
15'
5 gal.
14.5"
14"
18"
13 lbs.
61156
11753
40181
NA
NA
60908
NA aero 7 Gal.
120 V
60 Hz
1200 Watts
600 Watts
120 CFM
65"
3.5 sq. ft.
62 db(A)
15'
7 gal.
14.5"
14"
21"
14 lbs.
60910
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual Page -5-
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipmentgrounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit and has a ground plug that looks like the plug illustrated in figure
1. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.
WARNING: To prevent possible electric shock, protect the machine from rain. Keep the machine in a dry building.
WARNING: To prevent possible electric shock, always use a 3-wire electrical system connected to the electrical ground. For maximum protection against electrical shock, use a circuit that is protected by a ground fault circuit interrupter. Consult your electrical contractor.
WARNING: Do not cut, remove or break the ground pin. If the outlet does not fit the plug, consult your electrical contractor.
WARNING: Have worn, cut or damaged cords replaced by an authorized service person.
Grounding
Pin
Grounded
Outlet
(A)
Figure 1
Grounded
Outlet
Box
EXTENSION CORDS
Use only an approved extension cord with three conductors, a plug with three terminals, and a connector body with three holes. The machine has a power cord with wire size 16
AWG (AWG means American Wire Gauge).
WARNING: If you use an extension cord, use an extension cord with minimum wire size 14 AWG.
Do not use an extension cord longer than 50 feet.
Do not join two extension cords.
APPLIANCE PLUG SOCKET
Before connecting any appliance to the appliance plug socket, the machine must always be switched off. If appliances are connected to the appliance plug socket, ensure that these appliances are also switched off when being connected to the appliance plug socket.
CAUTION: The operating instructions and the safety precautions contained therein must be observed when using appliances connected to the appliance plug socket of the machine.
Page -6 WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
HOW TO ASSEMBLE THE MACHINE
CAUTION!
On delivery, the accessories - are lying in the tank and must be removed before the machine is used for the first time. See figure 2.
To assemble the machine, remove the machine top section:
The power cord must not yet be inserted into a plug socket.
1. Open the retaining clamps and lift off the machine top section (Figure 3).
2. Place a bag-type filter into the tank as described in the instructions printed on the filter.
3. Fit the machine top section back on the tank, and close the retaining clamps.
4. Connect the suction hose. The "Wap Multifit" enables any Wap Technology suction hoses (27, 32, 36, 50 mm diameter) to be connected to the machine (Figure 4).
HOW TO PREPARE THE MACHINE FOR OPERATION
Electrical Compressed Air Connection
The operating voltage shown on the rating plate must correspond to the voltage of the main power supply.
Ensure that the machine is switched off and insert the plug of the power cord into a properly installed and fused plug socket with ground.
Connecting Electric Tools aero 7 AS/E:
Connect the electric tool to the appliance plug socket on the control panel (Figure 5).
Before connecting a tool, ensure that both the machine and the tool are switched off.
For maximum power consumption of the electric tool to be connected, see the Specification Table on page 5.
Figure 3
Figure 4
Figure 2
Figure 5
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual Page -7-
MACHINE OPERATION
Picking Up Dry Substances
Before picking up dry substances, the bag-type filter should always be installed in the tank. It is then easy to dispose of the material picked up and the service life of the main filter element is significantly increased. Dry cleaning without bag-type filter is also possible.
WARNING: Inflammable substances must not be picked up with the machine!
After picking up liquids, the filter element is damp.
Damp filter elements can clog more quickly when dry substances are picked up. For this reason, the filter element should be dried or replaced before picking up any dry substances.
Picking Up Liquids
Before picking up liquids, the bag-type filter must always be removed from the tank.
WARNING: Inflammable liquids must not be picked up with the machine!
If foaming is observed, stop work immediately and empty the tank.
Switching On The Machine (SQ 10/15/17 & aero 5)
Turn the switch to position "I" (Figure 6).
Switching On The Machine (aero 7 AS/E)
Two operating modes are possible.
1. Switch position "I":
The machine motor starts immediately.
2. Switch position "auto":
The machine motor starts only when the tool connected to the appliance plug socket is switched on (Figure 7).
CAUTION: Before turning the switch to position
"auto", ensure that the tool connected to the appliance plug socket is switched off.
The motor speed and thus the suction power can be varied at the suction force regulator. This permits a precise adaptation to different substances to be picked up (Figure 7).
After Finishing Work
1. Switch off the machine and pull the plug of the power cord out of the plug socket.
2. Wind up the power cord around the handle (Figure
8).
Page -8-
Figure 6
Figure 7
Figure 8
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
MACHINE OPERATION
Changing The Bag Type Filter
1. Close the bag-type filter sleeve with the slide
(Figure 9).
2. Pull the bag-type filter sleeve off the inlet fitting.
3. Dispose of the used bag-type filter in accordance with the local waste disposal regulations.
4. Place a new bag-type filter into the tank as described in the instructions printed on the filter.
IMPORTANT!
Push the bag-type filter sleeve completely onto the inlet fitting.
Replacing The Filter Element
1. Switch off the machine and pull the plug of the power cord out of the plug socket.
2. Remove the machine top section from the dirt tank and place to one side with the filter element facing upwards (Figure 10).
3. Unscrew the filter retaining nut (1) and remove together with the retaining washer (2).
4. Pull off the filter element (3).
5. Push on a new filter element.
6. Fit the filter retaining washer and tighten the retaining nut.
7. Dispose of the used filter element in accordance with the local waste disposal regulations.
MAINTENANCE AND REPAIR
CAUTION: Before cleaning and servicing the machine, always remove the power cord.
Carry out only maintenance operations described in these operating instructions. Use only original Wap
Technology spare parts.
CAUTION: Do not make any technical modifications to the machine. Your safety could be endangered as a result!
For all other maintenance and repair work, please contact and authorized Wap
Technology Service department.
Page -9-
Figure 9
Figure 10
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
Problem
Motor does not start.
Reduced suction power.
TROUBLESHOOTING
Cause
1. The fuse or plug socket has blown.
2. Overload protection switch has tripped.
1. Reset the fuse
Action
2. Allow the machine to cool down approximately
5 minutes; if the machine does not start again automatically, contact the Service Dept.
1. Bag-type filter full.
2. Suction hose clogged.
3. Filter element clogged.
1. Replace bag-type filter.
2. Clean suction hose.
3. Clean and replace filter element.
No suction power during wet cleaning.
1. Tank full (float switch closing off the suction opening).
1. Empty tank.
NOTES
Page -10 WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
aero / SQ
Wet/Dry Vacuum
Section II
Parts and Service
(70204A)
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
Page -11-
Page -11-
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
27
26
22
23
Page -12-
23
25
24
19
20
21
20
WAP TECHNOLOGY aero 5 Gallon aero 7 AS/E
Assembly Drawing 3/00
1
28
29
30
33
31
32
2
3
17
16 10
8
9
4
5
6
7
18
15
14
13
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
11
12
WAP TECHNOLOGY aero 5 Gallon aero 7 AS/E
Assembly Parts List 3/00
30
31
32
33
27
28
29
23
24
25
26
19
20
21
22
15
16
17
18
11
12
13
14
8
9
10
5
6
7
Ref.
Part No. Description Qty
3
4
1
2
11753
60606
60607
61156
Filter Element, Short
Float
Cage, Float
Filter Bag, aero 5 (pkg. of 5)
1
1
1
1
60910
2364
2793
65246
65247
61276
60608
60897
Filter Bag, aero 7 (pkg. of 5)
Cap Nut
U-Disc 8.4mm Zinc
Canister, aero 5
Canister, aero 7
Washer
Caster
Hose, vac
60609
40696
60916
14295
6084
60911
62352
11253
Wand Holder
2 pc. Wand Ext., Plastic
Cuff, Powertool
Universal Nozzle
Crevice Tool 9.5"
Curved Wand, Plastic
Floor Tool, 36mm
Screw 50 x 20
1
1
1
1
1
1
1
4
1
1
4
4
1
1
4
60605
60610
60933
46248
46297
49267
60867
11992
48338
60603
60601
60602
26797
60604
60285
60611
Bottom Housing
Motor Ring, Vac
Vac Motor, 120V 1000W
Automatic Start
Screw
Plug Cover, aero 7
Plug Socket
Switch, aero 5
Switch Complete
Screening Filter, aero 5
Handle
Top Cover, aero 5
Top Cover, aero 7
Clamp
Upper Housing
Power Cord
Foam
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual Page -13-
47
41
40
38
37
39
41
42
43
44
45
5
46
36
35
34
WAP TECHNOLOGY
SQ 10 & 15 Gallon
Assembly Drawing 3/00
32
33
1
2
48
3
4 12
5
6
8
7
12
10
14
13
15
16
31
Page -14-
9
11
17
28
18
19
29
30
27
26
25
24
23
22
20
21
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
WAP TECHNOLOGY
SQ 10 &15 Gallon
Assembly Parts List 3/00
46
47
48
42
43
44
45
38
39
40
41
34
35
36
37
30
31
32
33
26
27
28
29
22
23
24
25
19
20
21
10
11
12
13
8
9
6
7
14
15
16
17
4
5
2
3
Ref.
Part No. Description Qty
1 47014 Ring, Foam Rubber 1
47006
44239
26792
11253
Silencer
Lower Housing, SQ.
Ground Contact SQ. 10
Screw, 50mm x 20mm
1
1
1
1
18
11222
11256
48421
11835
45692
46418
11565
29747
47025
29753
31972
29739
Packing Ring, Gasket
Screw, 35mm x 18mm
Terminal Block
Float, Short
Deflector
Filter Frame
Screw, 50 x 18
Fleece Filter, SQ.
Covering
Filter Holder Disc, SQ.
Rubber Seal, Vac Motor
Filter Bags, 10 Gallon
14896
65243
Filter Bags, 15 Gallon
Canister, SQ 10 Blue
100006 Canister, SQ 15 Blue
29191 Packing Ring SQ
1
1
1
1
1
1
1
1
1
1
2
26797
43975
43435
43433
46298
15102
15805
11597
Clamp
Retaining Pin (Wheel)
Cap (Wheel)
Wheel
Cater Swivel
Swivel, Hose
Suction Hose 1.5" x 10'
Hose Cuff
2
2
2
2
1
1
1
29758
5103
15546
26774
26785
47035
44240
47015
Wand Bracket Set
Curved Wand, Chrome
Straight Wand EXT. (2 Pcs.)
Carbon Brush (Pair)
Vac, Motor Complete
Rubber Seal, Vac Motor
Upper Housing, SQ
Motor Ring
1
1
1
1
1
1
1
25700
29989
48338
29755
46297
46248
Air Diverter, SQ.
Rotary Switch, SQ.
Screening Filter
Control Panel
Plug Cover
Screw
49267 Plug Socket
243606 Knob, SQ.
1
1
1
1
1
1
1
1
1
1
1
1
1
9868
18274
11254
26801
26803
O Ring 10 x 2.5 mm
Screw
Screw
Handle
Cover SQ.
1
1
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual Page -15-
67
65
67
66
60
59
58
57
56
41
54
41
44
43
41
38
36
36
34
Page -16-
50
48
WAP TECHNOLOGY
SQ 17 Gallon
Assembly Drawing 3/00
68
69
63
70
64
62
61
2
1
4
5
41
41
55
53
52
51
49
6
7
12
13
14
9
10
11
3
8
18
19
20
46
45
21
42
22
23
24
40
23
21
39
37
35
33
26
27
28
30
29
28
30
29 32
31
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
25
25
15
16
17
WAP TECHNOLOGY
SQ 17 Gallon
Assembly Parts List 3/00
31
32
33
34
35
27
28
29
30
23
24
25
26
19
20
21
22
15
16
17
18
11
12
13
14
7
8
9
10
5
6
3
4
Ref.
Part No. Description Qty
1
2
5103
5067
Curved Wand, Chrome
Rubber Nozzle
47429
15365
11597
15102
Filter Bag, SQ. 17 (5 pcs.)
Hose, Vac 13' x 36 mm
Hose Cuff
Swivel, Hose
1
1
1
60738
60737
17847
17849
11565
46073
46223
29191
Belt, Front
Belt, Rear
Screw, 6mm x 20mm
Washer, 6.4 x 1.6
Screw, 50 x 18
1
1
19880
15889
60739
46134
17737
12496
60767
60746
Packing Ring SQ
Clamp
Rivet
Canister 17 Gal.
Handle Bar SQ.
Screw, Countersunk
Nut
1
2
4
1
1
60771
60744
7895
60741
46301
2758
30738
11474
End Cap
Panel, Side R.H.
Screw, Self Threading
Panel, Side L.H.
End Cap, Carriage Frame
Frame
Bracket, Frt. Carriage
Nut M8
1
1
2
2
4
1
2
1
46490
48647
29753
47025
29747
Screw, M8 x 30
Caster, Locking
Cap, Wheel
Wheel
Filter Holder Disc
Covering
Fleece Filter
1
3
1
2
2
2
62
63
64
65
58
59
60
61
66
67
68
69
70
54
55
56
57
50
51
52
53
46
47
48
49
42
43
44
45
38
39
40
41
Ref.
Part No. Description Qty
36
37
11565
46418
Screw, 50 x 18
Filter Frame 1
45692
11835
11222
11253
Deflector
Float, Short
Packing Ring Gasket
Screw, 50 x 20
1
1
1
26792
44239
48414
46640
47014
28875
26774
26785
Ground Contact
Lower Housing
Plug
Washer
Foam Ring
Motor Seal
Carbon Brushes (Pair)
Vacuum Motor Complete
1
1
2
1
1
1
2
1
1
47036
5697
11256
48421
44240
60285
25700
24738
Rubber Ring
Strain Relief
Screw 35 x 18
Terminal Block
Upper Housing SQ
Power Cord
Air Diverter
Screw
1
1
1
1
1
1
1
29989
48338
29755
11254
Rotary Switch
Screening Filter
Control Panel
Screw
18274
9868
Screw
O Ring 10 x 2.5
243606 Knob, SQ.
46297 Plug Cover, SQ
49267
46428
26801
26803
10029
Plug Socket
Screw
Handle SQ.
Cover SQ.
EJOT - Screw 5.0 x 25
1
1
1
1
1
1
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual Page -17-
NOTES
Page -18 WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
U. S. A. Locations
ALTO
®
PRODUCT SUPPORT BRANCHES
European Locations
HEAD OFFICE
ALTO U.S. Inc., St. Louis, Missouri
390 S. Woods Mill Rd., Suite 300
Chesterfield, Missouri 63017-3433
PRODUCTION FACILITIES
ALTO Danmark A/S, Aalborg
Blytaekkervej 2
DK-9000 Aalborg
+45 72 18 21 00
ALTO Danmark A/S, Hadsund
Industrikvarteret
DK-9560 Hadsund
+45 72 18 21 00
PRODUCTION FACILITIES
ALTO U.S. Inc., Springdale, Arkansas
2100 Highway 265
Springdale, Arkansas 72764
(501) 750-1000
Customer Service - 1-800-253-0367
Technical Service - 1-800-356-7274
ALTO U.S. Inc., Bowling Green, Ohio 43402
1100 Haskins
ALTO U.S. Inc., Clearwater, Florida 33765
1500 N. Belcher Road
SERVICE FACILITIES
ALTO U.S. Inc., Carlstadt, New Jersey 07072
150 Commerce Road
(201) 460-4774
ALTO U.S. Inc., Elk Grove, Illinois 60007
2280 Elmhurst Road
(847) 956-7900
ALTO U.S. Inc., Denver, Colorado 80211
4640 Lipan
(303) 455-2413
ALTO U.S. Inc., Houston, Texas 77040
7215 North Gessner Road
SALES AND SERVICE FACILITIES
ALTO U.S. Inc., Madison Heights, Michigan 48071-0158
29815 John R.
(810) 544-6300
ALTO U.S. Inc., Marietta, Georgia 30062
1355 West Oak Common Lane
(770) 973-5225
WAP TECHNOLOGY
Customer Service Headquarters
1500 N. Belcher Road
Clearwater, FL 33765
Technical Service
1-877-322-2586
WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
SALES SUBSIDIARIES
ALTO Canada Ltd., Rexdale Ontario
24 Constellation Ct.
(416) 675-5830
ALTO Overseas Inc., Sydney (Australia)
1B/8 Resolution Drive
Caringbah NSW 2229
+61 2 9524 6122
ALTO Cleaning Systems Asia Pte Ltd., Singapore
271 Bukit Timah Rd.
#04-11 Balmoral Plaza
Singapore 259708
+65 8366 455
ALTO Deutschland GmbH, Frondenberg (Germany)
Ardeyer Str. 15
D-58730 Frondenberg
+49 2373 754 200
ALTO Cleaning Systems (UK) Ltd., Penrith
Gilwilly Industrial Estate
Penrith
Cumbria CA11 9BN
+44 1768 868 995
ALTO France S.A. Strasbourg
B.P. 44, 4 Place d’Ostwald
F-67036 Strasbourg
Cedex 2
+33 3 8828 8400
ALTO Nederland B.V. Vianen
Stuartweg 4C
NL-4131 NJ Vianen
+31 347 324000
ALTO Sverige AB, Molndal (Sweden)
Aminogatan 18
Box 4029
S-431 04 Molndal
+46 3127 1600
ALTO Norge A/S, Oslo (Norway)
Bjornerudveien 24
N-1266
+47 2275 1770
Page -19-
WAP TECHNOLOGY WARRANTY
This Wap Technology Industrial/Commercial Product is warranted to be free from defects in materials and workmanship under normal use and service for a period of two years from the date of purchase, when operated and maintained in accordance with Wap Technology's Maintenance and Operations instructions.
This warranty is extended only to the original purchaser for use of the product. It does not cover normal wear parts such as electrical cable, rubber parts, hoses and motor brushes.
If difficulty develops with the product, you should:
(a). Contact the nearest authorized Wap Technology repair location or contact the Wap Technology Service
Operations Department, 1500 N. Belcher Road, Clearwater FL 33765, for the nearest authorized Wap Technology repair location. Only these locations are authorized to make repairs to the product under this warranty.
(b). Return the product to the nearest Wap Technology repair location. Transportation charges to and from the repair location must be prepaid by the purchaser.
(c). Wap Technology will repair the product and or replace any defective parts without charge within a reasonable time after receipt of the product.
Wap Technology's liability under this warranty is limited to repair of the product and/or replacement of parts and is given to purchaser in lieu of all other remedies, including INCIDENTAL AND CONSEQUENTIAL
DAMAGES.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE SPECIFIED HEREIN. THERE ARE NO
WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. NO WARRANTIES,
INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY, SHALL BE IMPLIED. A warranty registration card is provided with your Wap Technology product. Return the card to assist Wap Technology in providing the performance you expect from your new floor machine.
WAP TECHNOLOGY reserves the right to make changes or improvements to its machine without notice.
Always use genuine Wap Technology Parts for repair.
WAP TECHNOLOGY
1500 N. Belcher Road
Clearwater, FL 33765
Page -20 WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
advertisement
Related manuals
advertisement
Table of contents
- 3 Important Safety Instructions
- 5 Specifications and Accessories
- 6 Grounding Instructions
- 7 How To Assemble the Machine
- 7 How To Prepare The Machine For Operation
- 8 Machine Operation
- 9 Maintenance and Repair
- 10 Troubleshooting
- 12 Assembly Drawing for aero 5 Gallon and aero 7 AS/E
- 13 Parts List
- 14 Assembly Drawing for SQ 10 and 15 Gallon
- 15 Parts List
- 16 Assembly Drawing for SQ 17 Gallon
- 17 Parts List