Eemax PR024240 ProSeries™ 24kW Electric Water Heater Installation Manual

Add to My manuals
12 Pages

EemaX PR024240 is a technologically-advanced electric tankless water heater designed to provide a precise and energy-efficient hot water solution. With advanced flow rate and temperature sensors, it modulates power to maintain a user-selected output water temperature between 80°F and 140°F, subject to incoming water temperature and power. Suitable for indoor installation, it features auto-resetting thermostat switches for high-temperature protection and doesn't require venting. Installation by a qualified electrician and plumber is recommended. Enjoy endless hot water with EemaX PR024240.

advertisement

Eemax PR024240 ProSeries™ 24kW Electric Water Heater Installation Manual | Manualzz

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL

PRO SERIES

IMPORTANT SAFETY INFORMATION

When installing or using any high voltage electrical appliance, basic safety precautions should always be followed. Under no circumstances should you attempt to clean, install, inspect, repair, disassemble or otherwise service this water heater, without first shutting off

all

power to the unit directly at the breaker box.

SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.

THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR PLUMBER IN ACCORDANCE

WITH ALL NATIONAL, STATE, PROVINCIAL AND LOCAL ELECTRICAL & PLUMBING CODES.

PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE.

FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH.

This manual should be given to the homeowner after installation and should be retained for future reference.

Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance.

ABOUT YOUR TANKLESS WATER HEATER

Congratulations on the purchase of your Electric Tankless Water Heater! You have purchased the most technologically-advanced electric tankless water heater on the market today.

Your new electric tankless water heater features advanced water flow rate and temperature sensors designed to modulate power to the heating elements to maintain a precise user-selected output water temperature between 80°F and 140°F (subject to incoming water temperature and power of the selected model).

To get the best performance and energy savings from your electric tankless water heater, it is important that it be installed in accordance with our instructions and the electrical and plumbing codes applicable to your area, and that you read this manual thoroughly for important operating instructions and tips.

At any time, if you have any questions, please contact us directly at:

Eemax Inc.

400 Captain Neville Drive, Waterbury, CT 06705

Toll Free: 1-800-543-6163, or 203-267-7890 Fax: 203-267-7975 [email protected]

CONTENTS

1.

BEFORE INSTALLATION

2.

SELECTING A LOCATION TO INSTALL

3.

MOUNTING YOUR WATER HEATER

4.

PLUMBING INSTALLATION

5.

ELECTRICAL INSTALLATION

6.

SIZING GUIDE

7.

GENERAL OPERATING INSTRUCTIONS

8.

MAINTENANCE

9.

TROUBLE SHOOTING GUIDE

10.

USER INTERFACE

1- BEFORE INSTALLATION

PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE.

FAILURE TO FOLLOW INSTRUCTIONS COULD CAUSE PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR

DEATH.

By installing this product, you acknowledge the terms of the manufacturer’s warranty. Once the heater is installed, do not return product to the place of purchase. If you have any questions regarding the warranty or product return policies, please contact Eemax at 800-543-6163.

Inspect all components. The contents of your box should include one of the following units:

PR008240

PR011240

PR013240

PR018240

PR024240

PR027240

PR036240

2SELECTING A LOCATION TO INSTALL

This product is designed to be installed indoors only. You may be able to install your unit in an outdoor location as long as it is mounted in a suitable enclosure that protects it from rain, splashed water, direct sunlight, debris, and insects.

DO NOT install this product in a location where it may be subject to freezing temperatures. If the water inside your tankless water heater freezes, it can cause severe and permanent damage that is not covered under your warranty.

DO NOT locate the water heater in a location that is difficult to access.

Make sure that the water heater and hot water outlet pipe are out of the reach of children so they cannot tamper with the temperature controls or injure themselves by touching the hot water outlet pipe. The outlet water pipe can get very hot.

This product does NOT require venting.

Avoid installing your tankless water heater in a location prone to excessive humidity, moisture, or dust, or in an area where it may be splashed with water or other liquids. DO NOT install under water pipes or air conditioning lines that might leak or condense moisture that could then drip onto the heater. DO NOT install above electrical boxes or junctions.

If you plan to install your water heater on a second floor or in a heated attic space, make sure that you follow all code requirements for such installations as required for your area. We recommend that you install a drip pan

(connected to a safe drain) below the water heater to avoid property damage in the unlikely event of a leak.

Alternatively, you can install an active water leak detector and shutoff valve designed to turn off your water supply in the event that a leak is ever detected.

3MOUNTING YOUR WATER HEATER

Your tankless water heater should be secured to the mounting surface with 4 screws (minimum 1 inch long) using the built-in mounting brackets on each side of the heater. Make sure that the mounting surface is solid and secure, and ensure that the unit is level prior to securing the screws. For ease of installation and servicing, we recommend that this product be installed in an upright position with the inlet and outlet water connections at the bottom of the unit for the 18, 24, 27, and 36 kW models, and with the inlet and outlet water connections on the left and right sides of the unit for the 8, 11, and 13 kW models.

Recommended Clearances:

12 inches above and below the heater

6 inches in front of and to the sides of the heater

CAUTION: Combustible materials should be kept at least 24 inches away from your water heater and the hot water outlet pipe.

4- PLUMBING INSTALLATION

Please follow all plumbing instructions carefully. We recommend that this product be installed by a licensed and qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes.

Installation Instructions

STEP 1:

Connect the HOT WATER line to the water heater marked HOT WATER OUTLET located on the left side of the heater when facing unit. Connect the COLD WATER line to the water heater marked COLD WATER INLET on the right side when facing unit.

STEP 2:

After tightening both fittings at the water heater, open several hot water faucets and allow water to run though the water heater for at least 2 to 3 minutes. This process purges all the air from the water lines and

MUST be performed prior to turning on the power at the unit. FAILURE TO FOLLOW THIS STEP CAN CAUSE

PERMANENT DAMAGE TO THE HEATING ELEMENTS. If any maintenance is performed on the water heater or the home’s plumbing system that may introduce air into the plumbing pipes, it is important to turn the power off to the water heater and purge the air out of the lines before allowing the unit to power up.

STEP 3:

Carefully inspect all connections, unions, and the pressure relief valve (if installed) for leaks.

IMPORTANT NOTES:

1.

Do not solder any pipes with unit connected to pipes – heat from soldering may damage the flow sensor. Doing so will also void the warranty.

2.

This Eemax tankless water heater is equipped with both computer-controlled and electro-mechanical auto resetting thermostat switches for high-limited temperature protection. Since this product does not use a storage tank, the use of a temperature pressure relief valve (T&P) is not required for most installations.

UL Standard 499 does NOT require that a pressure relief valve be used. However, a T&P valve may be required to meet installation codes in your area. If one is required, install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater. When connecting to Flex or High Temperature CPVC pipe, we recommend that a T&P valve be used for added safety.

Please note: Installations in the Commonwealth of Massachusetts and State of Kentucky require a pressure relief valve. Please check your local installation codes for any special requirements.

3.

The maximum operating water pressure is 150 PSI. If the water pressure is higher, a pressure reducing valve must be installed on the main incoming water supply line prior to installing the electric tankless water heater.

4.

Flexible water heater hoses can and are recommended to be used with your water heater as part of the installation. When connecting the inlet water pipe to the unit, make sure to use a wrench to hold the units connection, and another wrench to tighten, so the flow sensor on the unit is not loosened or damaged. Serious internal damage to the water heater can occur if the inlet or outlet connections are over tightened or if solder connections were made.

5.

We recommend that a manual shut-off valve (ball valve) be installed on the inlet and outlet of the water heater so there is a convenient shut-off point available in the event that future maintenance or servicing is required. Before connecting pipes to the water heater, it is extremely important to flush the lines to eliminate all plumbing paste or residue in the lines caused by any welding or soldering.

We recommend that all the water pipes or hoses within 3 feet of the inlet and outlet connections be rated for high temperature applications with a 150°F minimum.

5- ELECTRICAL INSTALLATION

Eemax recommends that this product be installed by a licensed and qualified electrician in accordance with all applicable national, state, provincial, and local electrical codes. As with all electrical appliances, under no circumstances should you attempt to install, repair or disassemble this water heater without first shutting off all power to the unit directly at the fuse or breaker box. Make sure to shut off all breakers. SERIOUS BODILY INJURY OR

DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.

All wiring (wire gauge) and circuit protection (breakers) must comply with the U.S. National Electrical Code (NEC) in the U.S.A., or the Canadian Electrical Code (CEC) in Canada. Failure to do so could result in property damage and/or personal injury, and void your warranty. Note: the Canadian Electrical Code generally requires that all supply wires and corresponding circuit protection used for domestic hot water heating and hydronic heating applications be sized to a minimum of 125% of the maximum current rating of the heater (see model specifications below for details).

Before installing this product, ensure that the home has sufficient electrical power available to handle the maximum amperage load of the applicable model.

IMPORTANT NOTES:

Model PR008240, PR011240, and PR013240 require 1 set of wires and ground

(see wiring diagram)

Model PR018240 requires 2 sets of wires and ground

(see wiring diagram)

Model PR024240 and PR027240 require 3 sets of wires and ground

(see wiring diagram)

Model PR036240 requires 4 sets of wires and ground

(see wiring diagram)

Please see required wire gauge on the next page

Each set of wires must be connected to its own individual double pole breaker

Installation Instructions

STEP 1:

Take each wire pair and connect them to one breaker (see wiring diagram). Make sure that each breaker is connected with one black wire and one red wire

STEP 2:

Using a suitable wire gauge that meets all applicable electrical codes for the size of the breakers used, run the correct sets of wire from the home’s main breaker panel to the tankless water heater.

STEP 3:

A separate ground conductor for each incoming circuit is required.

STEP 4:

DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connections are tight and secure. Also confirm that the correct breaker size and wire gauge has been used and confirm that the unit has been connected to a ground in accordance with applicable codes.

STEP 5:

Confirm that all the air has been purged from the water lines prior to turning on power to the unit. Refer to

STEP 2 in the plumbing installation section.

CAUTION

: Ensure that you have made the correct connections. You must follow the wire connection as shown to ensure proper operation of the unit. If you mix up one set of wires with another, the unit will not operate correctly even though it turns on and otherwise appears to function properly.

The water heater is now installed and ready to use! Follow the General Operating Instructions to complete the set up. We highly recommend that this is done with the homeowner present.

MODELS

ELEMENTS

VOLTAGE

MAX kW kW PER ELEMENT

MAX AMPERAGE DRAW

REQUIRED BREAKERS

REQUIRED WIRE GAUGE

Electrical Specifications by Model

PR008240 PR011240 PR013240 PR018240 PR024240 PR027240 PR036240

1

240 V

8 kW

8 kW

33 AMPS

1 x 40 AMP

1 x 8 AWG

2

240 V

11 kW

5.5 kW

46 AMPS

1 x 50 AMP

1 X 6 AWG

2

240 V

13 kW

6.5 kW

54 AMPS

1 X 60 AMP

1 X 6 AWG

2

240 V

18 kW

9 kW

75 AMPS

2 X 40 AMP

2 X 8 AWG

3

240 V

3

240 V

24 kW

8 kW

100 AMPS

3 x 40 AMP

3 x 8 AWG

27 kW

9 kW

112.5 AMPS

3 X 40 AMP

3 X 8 AWG

4

240 V

36 kW

9 KW

150 AMPS

4 X 40 AMP

4 X 8 AWG

Red

Bla

Circuit Breaker #1

L1 L1

Black

Circuit Breaker #2

L2 L2

Red

Bla

Black

Circuit Breaker #3

L3 L3

Red

Bla

Black Red

Bla

Circuit Breaker #4

L4 L4

Black

PR008240-PR011240-

PR013240 require 1 set of breakers and wires

PR018240 requires 2 sets of breakers and wires

PR024240-PR027240 require 3 sets of breakers and wires

PR036240 requires 4 sets of breakers and wires

6- SIZING GUIDE

Please use the chart below to see how many gallons per minute your tankless water heater can produce with your incoming water temperature. The gallons per minute is calculated assuming 105°F outlet temperature.

Incoming

Water

Temperature

PR008240 PR011240 PR013240 PR018240 PR024240 PR027240 PR036240

40°F

45°F

50°F

55°F

60°F

65°F

70°F

75°F

80°F

0.8

0.9

1.0

1.1

1.2

1.4

1.6

1.8

2.2

1.2

1.3

1.4

1.5

1.7

1.9

2.2

2.5

3.0

1.4

1.5

1.6

1.8

2.0

2.2

2.5

3.0

3.6

1.9

2.0

2.2

2.5

2.7

3.1

3.5

4.1

4.9

2.5

2.7

3.0

3.3

3.6

4.1

4.7

5.5

6.6

2.8

3.1

3.4

3.7

4.1

4.6

5.3

6.1

7.4

3.8

4.1

4.5

4.9

5.5

6.1

7.0

8.2

9.8

(Gallons per Minute)

FLOW RESTRICTOR – OPTIONAL

In order to ensure the optimal temperature output and overall performance of your tankless water heater you may require a flow restrictor. These flow restrictors are installed on the outlet connection of your tankless water heater and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit temperature from becoming too cool. To learn more about flow restrictors or find out how to purchase one for your tankless water heater visit us online at Eemax.com or contact us at 1-800-543-6163.

Steps for Choosing a Flow Restrictor

1.

Find your model in the chart on the left

2.

Choose the column with the inlet water temperature closest to your geographical location

3.

Take the GPM or gallons per minute you find and match it with the corresponding flow restrictor on the right

Inlet Water Temperature

40°F 50°F 60°F 70°F

Eemax Part Number Maximum Flow Rate Connection Size

PR008240

1.0

PR011240

1.0

PR013240

1.0

PR018240

2.0

1.0

1.0

1.5

2.0

1.0

1.5

2.0

2.0

1.5

2.0

2.0

3.0

IFR 1-2

PR024240

2.0

PR027240

2.0

2.0

3.0

3.0

4.0

4.0

5.0

IFR 3-4

PR036240

3.0 4.0 5.0 5.0

*Selection based on inlet temperature above and outlet temperature of 105°F

1.0 GPM

1.5 GPM

2.0 GPM

2.0 GPM

3.0 GPM

4.0 GPM

5.0 GPM

1/2" Compression

1/2" Compression

1/2" Compression

3/4" NPT

3/4" NPT

3/4" NPT

3/4" NPT

7GENERAL OPERATING INSTRUCTIONS

Operating your new tankless water heater is very similar to using any traditional water heating system.

However, it is very important that you carefully read all of the set-up procedures and operating instructions and tips to ensure the maximum performance and energy savings from your new water heater. We recommend that all members of the household read these General Operating Instructions.

6-

How your new water heater works:

Your tankless water heater does not store hot water like a conventional tank-type water heater. It contains very high powered heating elements that are capable of heating water ondemand. As soon as you turn on a hot water faucet, a sophisticated flow sensor recognizes that you have turned on the water. This sensor measures flow rate while another sensor measures the incoming water temperature. This information is transmitted continually to the computer logic controls which decide how much power to send to the heating elements to heat the water to your desired temperature. Once the water faucet is turned off your water heater will turn off as well.

7-

8-

8MAINTENANCE

To ensure maximum performance of your water heater and to reduce the risk of a water leak, we recommend the following maintenance:

You should inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure. Any signs of damage, cracks, leakage or weakness should be addressed. Take care not to over-tighten the connections. Serious internal damage to your water heater can occur if you over- tighten the water heater connections at the unit.

IMPORTANT NOTES:

As with all electrical appliances, under no circumstances should you attempt to install, repair or disassemble this water heater without first shutting off all power to the unit directly at the fuse or breaker box. SERIOUS BODILY

INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.

When any maintenance is performed on the water heater or the home’s plumbing system that may introduce air into the plumbing pipes, it is important to turn the power off to the water heater and purge the air out of the lines before allowing the unit to power up. FAILURE TO DO SO COULD CAUSE PERMANENT DAMAGE TO THE HEATING

ELEMENT AND VOID YOUR WARRANTY.

If you have a water supply with a high level of mineralization (hard water), you should increase the frequency of your maintenance.

9TROUBLE SHOOTING GUIDE

Are you having problems with your water heater?

Please call or email our customer service and technical support team for any help you may need

TOLL FREE 1-800-543-6163 [email protected]

The following table represents some of the most common technical support questions we receive. Before calling us, please read thoroughly to see if your question or problem is addressed.

PROBLEM POSSIBLE CAUSE SOLUTION

Water heater is not heating at all (water is flowing but the unit is not heating at all —the outgoing water temperature is the same as my cold water supply) - the digital display does NOT light up.

No power or incorrect wiring. Make sure the breakers at main electrical panel are ON. You may have a faulty breaker or unit may be wired incorrect.

Flow rate is too low / water pressure is too low.

Your water heater has an activation flow rate of approximately 0.3 GPM. If your water flow rate is less than this level, your unit will not activate. Increase the flow rate.

Please call us for technical assistance.

Water heater is not heating at all (water is flowing but the unit is not heating at all - the outgoing water temperature is the same as my cold water supply)

The digital display DOES light up.

Internal part failure.

Water heater is heating but the water temperature is not hot enough.

User temperature setting too low.

Flow rate is too high.

Turn up the temperature setting on the unit.

Depending on your incoming water temperature and the power output of your model, your water flow rate may exceed the physical heating capacity of your water heater.

Reduce the flow rate by installing an Eemax Flow Restrictor.

Use the chart in section 6 to find out which flow restrictor works best for your particular model.

Crossed wires.

Voltage less than 240 volts.

If it’s a new installation, have your electrician double check the wiring. Is possible that the wiring is incorrect.

The heating elements on your water heater are design for

240 volts. When use with a lower voltage, they produce less heating power. You may need to upgrade to a larger model.

Mixing too much cold water.

You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater. You may also have an anti-scald feature on your faucet that is mixing cold water. These types of faucets can usually be adjusted to reduce the amount of cold water mixed.

The water temperature at my faucet is less than the temperature setting of my water heater.

Voltage less than 240 volts.

Anti-Scald pressure/balancing valve or tempering valve.

Thermal loss due to long pipe run

The computer chips in your tankless water heater are programmed with the expectation that your incoming line voltage is 240 volts. If you have less than 240 volts, it may affect the reading on your water heater’s digital display and cause it to read slightly higher than the actual output temperature. To compensate for this, increase the setting on your water heater if you need / want hotter water.

Your faucet may have an anti-scald feature or a tempering valve that automatically mixes cold water even when you turn your control lever or handle to full hot. These devices are usually adjustable so you can turn off the cold mix completely. You can compensate for this by increasing the setting on your water heater if you need/want hotter water.

As the hot water from the heater runs through the hot water delivery system to you faucet, some heat will be lost especially if it has long distance to travel or the pipes are cold. This is normal. You can compensate for this by increasing the setting on your water if you need/want hotter water.

10USER INTERFACE

Power

Click adjustment stem, the display will turn on

Click the adjustment stem again, the display will turn off

C/F Conversion

Press the stem for 3 seconds, the display will change from Fahrenheit to Celsius or vice versa

Temperature Control

Turning the stem clockwise increases the set output water temperature

Turning the stem counter clockwise decreases the set output water temperature

You can set or adjust your temperature at any time between 80°F – 140°F (4°C – 60°C). The temperature can be changed to your desired setting. The display will only stay on when the unit is in use or when you are setting the temperature.

CAUTION

– removing the cover to change the temperature set point exposes electrical shock and burn hazards, which can cause INJURY or DEATH. Adjustment should only be done by a licensed plumber or electrician.

PR008240 – PR011240 – PR013240 PR018240 – PR024240 – PR027240 – PR036240

1.

Hot Water Outlet

2.

Cold Water Inlet

3.

Celsius/Fahrenheit Conversion

(Remove Cover to Access - Press & Hold 3 sec.)

Model Number

PR008240

PR011240

PR013240

PR018240

PR024240

PR027240

PR036240

4. Temperature Set Point Display

(Remove Cover to Access)

5. Adjustment Stem & Temperature Control

(Remove Cover to Access)

Depth

3.75 inches

3.75 inches

3.75 inches

4.5 inches

4.5 inches

4.5 inches

4.5 inches

Width

9.75 inches

9.75 inches

9.75 inches

14 inches

17 inches

17 inches

21 inches

6. Wire Connection

7. Brass Compression Nut

8. Brass Compression Ferrule

Height

12 inches

12 inches

12 inches

17.75 inches

17.75 inches

17.75 inches

17.75 inches

Eemax Inc.

400 Captain Neville Drive, Waterbury, CT 06705

Toll Free: 1-800-543-6163 or 203-267-7890 Fax: 203-267-7975 [email protected]

advertisement