INSTALLATION MANUAL

Type : ART COOL Mirror

LG

IMPORTANT

• Please read this installation manual completely before installing the product.

• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

• Please retain this installation manual for future reference after reading it thoroughly.

IMPORTANT!

Please read this instruction sheet completely before installing the product.

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

WARNING

• Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the National Electrical

Code NFPA 70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

CAUTION:

Improper installation, adjustment, alteration, service or maintenance can void the warranty.

The weight of the condensing unit requires caution and proper handling procedures when lifting or moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges.

Safety Precautions

• Always wear safety eye wear and work gloves when installing equipment.

• Never assume electrical power is disconnected. Check with meter and equipment.

• Keep hands out of fan areas when power is connected to equipment.

• R-410A causes frostbite burns.

• R-410A is toxic when burned.

NOTE TO INSTALLING DEALER

: The Owners Instructions and Warranty are to be given to the owner or prominently displayed near the indoor Furnace/Air Handler Unit.

Special warnings

When wiring:

Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician should attempt to wire this system.

• Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

• Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

• Ground the unit following local electrical codes.

• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When transporting:

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger.

When installing...

... in a wall:

Make sure the wall is strong enough to hold the unit's weight.

It may be necessary to construct a strong wood or metal frame to provide added support.

... in a room:

Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to wall and floors.

... in moist or uneven locatinons:

Use a raised concrete pad or concrete blocks provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

... in an area with high winds:

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

... in a snowy area(for Heat Pump Model):

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When connecting refrigerant tubing

• Keep all tubing runs as short as possible.

• Use the flare method for connecting tubing.

• Check carefully for leaks before starting the test run.

When servicing

• Turn the power OFF at the main power box(mains) before opening the unit to check or repair electrical parts and wiring.

• Keep your fingers and clothing away from any moving parts.

• Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

2

Indoor Unit

Artcool Deluxe Type Indoor Unit Installation Manual

TABLE OF CONTENTS

Installation Requirements

Installation Parts

....................4

Required Parts Required Tools

Safety Precautions

.................5

Installation ...............................7

Selection of the best location

................................................7

Installation guide map

Four type "A" screws & plastic anchors

Connecting cable

Piping Method........................8

Pipes: Gas side

Liquid side

(Refer to Product Data)

Insulation materials

Additional drain pipe

Level gauge

Screw driver

Electric drill

Hole core drill

Horizontal meter

Flaring tool set

Specified torque wrenches

(different depending on model No.)

Spanner .......Half union

Drain Piping .........................13

A glass of water

Screw driver

Wiring Connection ...............13

Installation of Wireless

Remote Controller ...............15

Installation of Wired Remote

Controller..............................15

Two type "B" screws

Hexagonal wrench

Gas-leak detector

Vacuum pump

Gauge manifold

Owner's manual

Thermometer

Holder Remote Controller

Installation Manual

3

Installation Parts

Installation Parts

S8 SE

Installation Plate Installation Plate

S8

Installation plate(1EA)

SE

Installation plate(1EA)

Type "A" screws and plastic anchors(4 EA)

Type "B" screw (2 EA)

Type "A" screws and plastic anchors(4 EA)

Type "B" screw (2 EA)

4

Indoor Unit

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Be sure to read before installing the air conditioner.

Be sure to observe the cautions specified here as they include important items related to safety.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

Installation

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

• There is risk of fire or electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service

Center.

• Do not disassemble or repair the product. There is risk of fire or electric shock.

Install the panel and the cover of control box securely.

Always install a dedicated circuit and breaker.

Always ground the product.

• There is risk of fire or electric shock.

Use the correctly rated breaker or fuse.

• There is risk of fire or electric shock.

• Improper wiring or installation may cause fire or electric shock

• There is risk of fire or electric shock.

Do not modify or extend the power cable.

• There is risk of fire or electric shock.

For installation, always contact the dealer or an Authorized

Service Center.

• There is risk of fire, electric shock, explosion, or injury.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

• Moisture may condense and wet or damage furniture.

Be cautious when unpacking and installing the product.

• Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.

Do not install the product on a defective installation stand.

Be sure the installation area does not deteriorate with age.

• It may cause injury, accident, or damage to the product.

• If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

Installation Manual

5

Safety Precautions

Operation

Do not store or use flammable gas or combustibles near the product.

• There is risk of fire or failure of product.

Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

Install the drain hose to ensure that water is drained away properly.

Keep level even when installing the product.

• Low refrigerant levels may cause failure of product.

• A bad connection may cause water leakage.

• To avoid vibration or water leakage.

Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.

• It may cause a problem for your neighbors.

Use two or more people to lift and transport the product.

• Avoid personal injury.

Do not install the product where it will be exposed to sea wind

(salt spray) directly.

• It may cause corrosion on the product.

Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.

• The chemicals in batteries could cause burns or other health hazards.

6

Indoor Unit

Installation

Installation

Read completely, then follow step by step.

Selection of the best location

There should not be any heat source or steam near the unit.

• There should not be any obstacles to prevent the air circulation.

• A place where air circulation in the room will be good.

• A place where drainage can be easily obtained.

• A place where noise prevention is taken into consideration.

• Do not install the unit near the door way.

• Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles.

The mounting wall should be strong and solid enough to protect it from the vibration.

Mount the installation plate on the wall with four

Type "A" screws.

(If mounting the unit on the concrete wall, consider using anchor bolts.)

• Always mount the Installation plate horizontally by aligning the marking-off line by means of the thread and a level.

More than

100mm(3-15/16 inch)

More than

2300mm

(90-9/16 inch)

More than

200mm(7-7/8 inch)

More than

100mm(3-15/16 inch)

S8 chassis

Chassis

Hook

SE chassis

Installation Plate

Type “A”

Installation Plate

Chassis

Hook

Type “A”

The lower left and the right side of Installation Plate

S8 chassis SE chassis

Ø70mm

(2-3/4 inch)

133mm

(5-1/4inch)

Left rear piping

Ø70mm

(2-3/4 inch)

Installation plate

100mm

(3-15/16inch)

Right rear piping

Ø70mm

(2-3/4 inch)

85mm(3-3/8 inch)

Left rear piping

Installation plate

65mm(2-9/16 inch)

Ø70mm

(2-3/4 inch)

Right rear piping

CAUTION : In case that the unit is installed near the sea, the installation parts may be corroded by salt. The installation parts (and the unit) should be taken appropriate anti-corrosion measures.

Installation Manual

7

Installation

Drill a Hole in the Wall

• Drill the piping hole with a ø70mm hole core drill.

Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.

Indoor

WALL

Outdoor

Piping Method

Preparing the indoor unit's piping and drain hose for installation through the wall.

Remove the plastic tubing retainer(see illustration below) and pull the tubing and drain hose away from chassis.

Replace the plastic tubing holder in the original position.

3. Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.

For right rear piping

1. Route the indoor tubing and the drain hose in the direction of rear left.

Drain hose

2. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

Tape

Connecting pipe

Drain hose

Connecting cable

NOTICE

: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

*Foamed polyethylene or equivalent is recommended.

4. Indoor unit installation

Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.

Connecting cable

Drain hose

Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

8

Indoor Unit

5. Connecting the pipings to the indoor unit and drain hose to drain pipe.

Align the center of the pipings and sufficiently tighten the flare nut by hand.

Indoor unit tubing

Flare nut Pipings

Tighten the flare nut with a wrench.

Torque wrench

Indoor unit tubing

Spanner (fixed)

Flare nut

Connection pipe

Mount the clamp on the boss with a type "B" screw.(optional)

Type "B" screw

Clamp

Boss

Drain hose

Installation

Wrap the area which accommodates the rear piping housing section with vinyl tape.

Connection pipe

Vinyl tape

(wide)

Indoor unit pipe

Wrap with vinyl tape

Connecting cable

Pipe

Vinyl tape(narrow)

Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section.

Wrap with vinyl tape

Pipe

Vinyl tape(wide)

Drain hose

For left rear piping

1. Route the indoor tubing and the drain hose to the required piping hole position.

When extending the drain hose at the indoor unit, install the drain pipe.

Drain pipe

Indoor unit drain hose

Adhesive

Vinyl tape(narrow)

6. Wrap the insulation material around the connecting portion.

Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap.

Plastic bands

Insulation material

2. Insert the piping, drain hose and the connecting cable into the piping hole.

Connecting cable

Drain pipe

Installation Manual

9

Installation

3. Insert the connecting cable into the indoor unit.

Don't connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

4. Tape the drain hose and the connecting cable.

• Connecting cable

5. Indoor unit installation

Hang the indoor unit from the hooks at the top of the installation plate.

Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall.

When extending the drain hose at the indoor unit, install the drain pipe.

Drain hose

Indoor unit drain hose

Vinyl tape (narrow)

Adhesive

7. Wrap the insulation material around the connecting portion.

Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap.

Plastic bands

Insulation material

Indoor unit

Spacer

Installation plate

80mm

6. Connecting the pipings to the indoor unit and the drain hose to drain pipe.

Align the center of the pipings and sufficiently tighten the flare nut by hand.

Wrap the area which accommodates the rear piping housing section with vinyl tape.

Connection pipe

Vinyl tape

(wide)

Indoor unit piping

Wrap with vinyl tape

Connecting cable

Pipe

Vinyl tape

(narrow)

Indoor unit tubing Flare nut Pipings

Tighten the flare nut with a wrench.

Torque wrench

Indoor unit tubing

Spanner (fixed)

Flare nut

Connection pipe

10

Indoor Unit

Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section.

Drain hose

Pipe

Vinyl tape

(narrow)

Wrap with vinyl tape(wide)

Installation

9. Set the pipings and the drain hose to the back of the chassis with the tubing holder.

Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis.

Tubing holder

8. Reroute the pipings and the drain hose across the back of the chassis.

Piping for passage through piping hole

10. Indoor unit installation

Remove the spacer.

Ensure that the hooks are properly seated on the installation plate by moving it left and right.

Connecting cable

Drain hose

Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Installation Manual

11

Installation

CAUTION

Installation Information (For left piping)

• Good case

For left piping. Follow the instruction below.

Press on the upper side of clamp. ( )

CAUTION

• Bad case

Following bending type from right to left could cause problem of pipe damage.

Unfold the tubing to downward slowly. ( )

12

Indoor Unit

Installation

Drain Piping

1. To remove the front panel from the indoor unit, remove the front panel from the indoor unit cabinet.

Set the air direction louvers up-and-down to the position(horizontally) by hand.

Remove the securing screws that retain the front panel. Pull the lower left and right sides of the grille toward you and lift it off.

Connecting area drain hose

Leakage checking

Drain pan

Front panel

2. To check the drainage.

Pour a glass of water on the evaporator.

Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit.

Leakage checking

Drain hose

The drain hose should point downward for easy drain flow.

Downward slope

Do not make drain piping.

Do not raise

Accumulated drain water

Air

Water leakage

Water leakage

Waving

Water leakage

Tip of drain hose dipped in water

Ditch

Less than

50mm gap

Wiring Connection

Connect the wires to the terminals on the control board individually according to the outdoor unit connection.

• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.

Connecting caable

Terminal Block Indoor

1(L1) 2(L2) 3 4

SODU

B A -

IDU

-

INTERNET DRY1 DRY2 GND 12V

B A -

Outdoor unit

INDOOR POWER INPUT

Installation Manual

13

Installation

Connection method of the connecting cable(Example)

Conduit

Lock nut

Conduit mounting plate

1(L1) 2(L2)

3(A) 4(B)

Power Supply

High Voltage

(208/230V)

Transmission

Conduit

Lock nut

Conduit mounting plate

WARNING : Loose wiring may cause the terminal to overheat or result in unit malfunction.

A fire hazzard may also exist.

Therefore, be sure all wiring is tightly connected.

CAUTION:

After the confirmation of the above conditions, prepare the wiring as follows:

1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.

2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)

3) Specification of power source.

4) Confirm that electrical capacity is sufficient.

5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.

6) Confirm that the cable thickness is as specified in the power source specification.

(Particularly note the relation between cable length and thickness.)

7) In a wet or moist area, always install an earth leakage circuit breaker.

8) The following would be caused by voltage drop.

• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload.

9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors.

14

Indoor Unit

Installation of Wireless Remote Controller

How to mount onto a wall

Installation

How to insert the batteries

1. Remove the battery cover by pulling it according to the arrow direction.

2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.

3. Reattach the cover by sliding it back into position.

NOTICE

1. Always use/replace both batteries of same type.

2. If the system is not to be used for a long time, remove the batteries to save their working life.

3. If the display screen of remote controller starts, fading replace both of the batteries.

Installation of Wired Remote Controller

1. Connect the wired remote controller cable to the wired remote controller installation board as shown in the right picture.

12V SIG GND

12V

SIG

GND

Red wire

Yellow wire

Black wire

The wired remote controller cable is connected as factory default.

Red

Yellow

Black

2. After fixing the cable to the guide slot, attach the wired remote controller installation board at the desired location.

• Before fixing the wired remote controller cable to the guide slot, remove any clogged part of the case in the direction to install before the installation.

<Front side of installation board>

Remote Controller

Cable

Guide slot

<Rear side of installation board>

Installation Manual

15

Installation

3. After locating the wired remote controller installation board at the desired location, screw the unit firmly. (When there is a buried box, install the wired remote controller board to fit the buried box.)

• Use the screw provided.

4. After fixing the top part of the wired remote controller to the installation board as shown in beside picture, press the bottom part to assemble the controller to it’s board.

When disassemble the wired remote controller from the installation board, use the driver as shown in the right picture and insert it into the hole with the arrow. And when you pull the driver in the front direction, the wired remote controller will be separated.

Top

Bottom

Fixate the remote controller cable to the guide slot.

Use the screws for fixate the unit firmly on the wall.

Installation board

Wall

Side

Wall

Side

Wall

Side

Wall

Side

Wall

Side

5. Use the connecting cable to connect the indoor unit and the wired remote controller.

Check whether the connector is connected correctly.

Indoor unit side

Connecting cable

6. When the distance between the wired remote controller and the indoor unit is 10m and above, use the extension cable.

16

When installing the wired remote controller, do not bury it in the wall.

(It can cause damage in the temperature sensor.)

Do not install the cable to be 50m or above.

(It can cause communication error.)

• When installing the extension cable, check the connecting direction of the connector of the remote controller side and the product side for correct installation.

• If you install the extension cable in the opposite direction, the connector will not be connected.

• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.

Indoor Unit

P/No.: MFL61995002

Printed in Korea

After reading this manual, keep it in a place easily accessible to the user for future reference.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What are the required tools for the installation of the LG ARNU243S8R2 indoor unit?
You will need an installation guide map, four type 'A' screws and plastic anchors, a connecting cable, a level gauge, a screw driver, an electric drill, a hole core drill, a horizontal meter, pipes for the gas and liquid sides, insulation materials, additional drain pipe, a flaring tool set, specified torque wrenches, and a spanner.
What important safety instructions should be followed during installation?
Always wear safety eye wear and work gloves during installation. Never assume that electrical power is disconnected. Check with a meter and equipment. Keep hands out of fan areas when the power is connected to equipment. R-410A refrigerant liquid causes frostbite burns. R-410A refrigerant gas is toxic when burned.
What are the steps involved in installing the LG ARNU243S8R2 indoor unit?
1. Select the best location for installation. 2. Install the installation plate on the wall. 3. Connect the refrigerant tubing. 4. Install the drain piping. 5. Make the electrical wiring connections. 6. Install the wireless or wired remote controller.
What precautions should be taken when installing the indoor unit in different locations?
When installing in a wall, ensure that the wall is strong enough to hold the unit's weight. When installing in a room, properly insulate any tubing run inside a room to prevent 'sweating'. When installing in moist or uneven locations, use a raised concrete pad or concrete blocks to provide a solid foundation for the outdoor unit. When installing in an area with high winds, securely anchor the outdoor unit with bolts and use a metal frame. When installing in a snowy area, install the outdoor unit on a raised platform and provide snow vents.
Download PDF

advertisement