Gecko in.k19 Keypad Quick Start Card
Add to My manuals4 Pages
Gecko in.k19 offers various features to enhance your spa experience. With its two-pump system, you can control the water flow and intensity. Choose between low and high speeds for each pump, or turn them off completely. Set the desired water temperature using the Up/Down keys, and the built-in timer will automatically turn off the pumps after 20 minutes. Activate the purge or filter cycles to maintain clean and healthy spa water. The Smart Winter Mode prevents freezing by turning on the pumps periodically.
advertisement
K-19
Two pump system
Spa functions
Single pump system
The Quick Reference Card provides a quick overview of your spa’s main functions and the operations accessible from your keypad.
Key 1
Press Key 1 to turn Pump 1 on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). A third time turns pump off.
A built-in timer automatically turns pump off after 20 minutes*, unless pump has been manually deactivated first.
The “Pump 1” indicator lights up when Pump 1 is on.
With dual-speed pump, indicator will flash when Pump 1 is on at low speed.
Key 2 (2 Pump System)
(If equipped with Pump 2)
Press Key 2 to turn Pump 2 on at low speed. Press a second time to turn pump to high speed. A third time turns pump off.
A built-in timer automatically turns pump off after 20 minutes*, unless it has been manually deactivated first.
The “Pump 2” indicator lights up when Pump 2 is on.
The indicator will flash when Pump 2 is on at low speed.
* Default time
K
ey 2 (2-Pump/Blower System)
(If equipped with blower)
Press Key 2 to turn Pump 2 on at high speed. Pressing a second time turns blower on.
A third press turns Pump 2 off but leaves blower on. A final press turns blower off.
A built-in timer automatically turns Pump 2/blower off after 20 minutes*, unless
Pump 2/blower has been manually deactivated first.
The “Pump 2” indicator lights up when Pump 2 is on.
The “Blower” indicator lights up when blower is on.
Light key
Press the Light key to turn light on. Press a second time to turn light off.
A built-in timer automatically turns light off after 2 hours, unless it has been manually deactivated first.
The “Light” indicator lights up when light is on.
Up/Down keys
Use Up or Down key to set desired water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection.
The "Set Point" icon indicates that the display shows the desired temperature, NOT the current water temperature!
OFF
Off Mode
(If present)
This mode allows you to stop all outputs for 30 minutes to perform a quick spa maintenance.
Press and hold Key 1 for 5 secs to activate the Off mode. Quickly press Key 1 to reactivate the system before the expiration of the 30-minute delay.
While the Off mode is engaged, the display will toggle between OFF and the water temperature.
Programming
the purge / filter cycles
Programming filter cycles
Depending on system configuration the system performs either purge cycles or filter cycles.
To program the filter cycles, you must enter these parameters: duration and frequency.
During a filter cycle, pumps & blower run at high speed for one minute to purge the plumbing. Pump 1 or CP then runs at low speed for the remainder of the cycle.
Setting filter cycle duration
Press and hold the Light key until the display shows dxx , with "xx" representing the duration in hours. (Default: 2 hours).
Use Up or Down key to change setting.
0 = no filtration 24 = continuous filtration
Note: it's not recommended to set this to "0".
Filter cycle frequency
Press the Light key again. The display will show Fx , with "x" representing the number of filter cycles per day (up to 4). (Default: twice a day).
Use Up or Down key to change setting.
When the desired setting is displayed, press the Light key to confirm. A filter cycle will start immediately.
The “Filter” indicator lights up when a filter cycle is on.
Setting the temperature display units
Quickly press the Light key again. The display will show either °F or °C .
Use Up or Down key to change units.
Press the Light key a last time to go back to normal mode.
°F = Fahrenheit °C = Celsius
Programming purge cycles
To program the purge cycles, you must select the frequency. During a purge cycle, all pumps and the blower run for one minute. To set purge cycles:
Purge cycle frequency
Press and hold the Light key until the display shows Fx , with "x" representing the number of purge cycles per day (up to 4).
Use Up or Down key to change setting.
When the desired setting is displayed, press the Light key to confirm. A purge cycle will start immediately.
The “Filter” indicator lights up when a purge cycle is on.
Water temperature regulation
In a regulation cycle, the system first generates water flow through the heater housing and the plumbing, in order to ensure accurate water temperature readings as well as avoiding heater activation in dry conditions.
After verifying pump activation and taking a water temperature reading if required, the system automatically turns the heater on to reach and maintain water temperature at
Set Point.
The “Heater” indicator lights up when the heater is on. It flashes when there is a request for more heat but the heater has not yet started.
Smart Winter Mode
Our Smart Winter Mode protects your system from the cold by turning pumps on several times a day to prevent water from freezing in pipes.
The “Smart Winter Mode” indicator lights up when the Smart Winter Mode is on.
Cooldown
While performing this task, the heater is not allowed to turn on and its icon flashes.
Troubleshooting
Hr
An internal hardware error has been detected.
Contact dealer or service supplier.
HL
The system has shut the heater down because the temperature at the heater has reached 119°F (48°C). Do not enter the water! Remove the spa cover and allow the water to cool down, then shut power off and power your spa up again to reset the system.
AOH
Temperature inside the spa skirt is too high, causing the internal temperature to increase above normal limits.
Open skirt and wait until error clears.
FLO
The system does not detect any water flow while the primary pump is running. Check and open water valves. Check for water level.
Clean filter. If the problem persists, call your dealer or service supplier.
Prr
A problem is detected with the temperature probe.
Call your dealer or service supplier.
OH
The water temperature in the spa has reached 108°F (42°C).
Do not enter the water! Remove the spa cover and allow the water to cool down to a lower temperature. Call your dealer or service supplier if problem persists.
rLy (Present only on older software version)
The system has detected a stuck relay error.
Call your dealer or service supplier.
UPL
No low level configuration software has been installed into the system.
Call your dealer or service supplier.
© Groupe Gecko Alliance Inc., 2017
All trademarks or registered trademarks are the property of their respective owners.
www.geckoalliance.com
9919-100805-C
Rev. 11-2017