QUICKSTART “BASIC” GUIDELINES FOR MODEL 9100 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD
UL 325 August
2018 Standard
Model 9100 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.
h1
ON
.
ON
1 2 3 4 5 6 7 8
SW
DO NOT power up and cycle the operator without “Physical Stops”
installed to stop the gate in the open and close positions (Chain stops
are included with the operator but other physical stops can be used).
Damage could occur to the gate and operator.
Chain stop’s rubber bumpers face toward operator. They will make
contact with the operator housing during the initial automatic
open/close limits setting sequence.
ain
Ch cket
Bra
1
ire p
g wto keem
n
i
t
xis rs fro
e e ine ay ts.
Us estra es aw g par
r ir vin
w o
m
U.S.A.
High Voltage Connection
1” minimum space between the gate and the operator housing.
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
2.5”
Conduit Area
Chain Adjustment
11”
Solenoid
Lock
15”
Adjust the chain nuts to tighten the chain.
Min.
The chain should sag no more than one
(1) inch per 10 feet of chain travel.
Do not over tighten the chain.
C
120 S. Glasgow Avenue
Inglewood, California 90301
• Chain bracket MUST line up with
idler wheels!
Physical Stops MUST be Used to Stop Gate
Op
Direning
e
Sw ctio
itc
n
• Chain MUST be parallel to gate!
Chain
Bracket
4”
Tip: It is recommended that a surge suppressor be
installed on the high voltage power lines.
115 VAC
HIGH VOLTAGE
115 VAC Connection
Concrete Pad
A
Center
21” Min.
n
di
un
ro e
G at
ti- Pl
g
49
10
IT
EX OP
LO
E
Gate
Frame
LTS
PS
X GA
TE
Doo
PH
ng,
AS
E
LO
AD
rKi
Inc
.,
60
Ing
Hz
lew
ood
, CA
EN
OP ER
TIM
EXIT
LOOP
KEY
SW
H
ITC
G
KIN
OR 0
DO02-01
46
ON
2
ON
1
2
3
4
5
E
RS VITY
REVE ITI
SENS
ad
Thi
s
det dept
e
h
21
loc rmin of th
”M
al b ed
e
in
con uil by con
cre ding soil cret imum
te r co con e p
eco de dit ad
mm s (re ion is
end info s an
ed) rce d
d
.
p
Loo
SW
1
SW
NC
NO
4”
ab mini
ove mu
gro m
un
d.
Two 115 VAC Convenience Outlets
Power safety and opening devices
that require 115 VAC power.
um
M
15”nduit
o
uit
r
we
Po t
AC ndui
Co
c
ch
-in .
4
/
s
e 3 ep
Us swe
h
t
wi
SW 2
1. ON
2. OFF
3. OFF
4. OFF
5. OFF
6. OFF
7. OFF
8. OFF
Note: SW 2, switch 1 is
turned on when plug-in
exit loop detector is
installed.
Chassis
Ground
High Voltage
AC Input Wire
Neu
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
Every time the 9100 is powered up, the First open
command will automatically run “2 open/close gate cycles”
that will locate and remember the gate’s open and close
limit positions. See “Automatic Open/Close Limit Adjustment” in Installation/Owner’s manual for more information.
Plug-In Loop Detectors
B Not included - Refer to the Installation/Owner’s manual
AND Loop Information Manual (available from
www.doorking.com) for more information on loops and
Cycles the operator
plug-in loop detectors.
when pressed.
Important Note: DoorKing highly recommends that loops
and loop detectors are installed with this slide gate
operator. A loop detection system will preventing the gate
from automatically opening or closing on a vehicle when it
The 9100’s open/close limits DO NOT have to be physically is in the gate’s path.
adjusted. Every time the 9100 is powered up, the first
open command will automatically run “2 open/close
gate cycles” that will locate and remember the gate’s
open and close limit positions. These limit positions are
C Not included - Refer to a specific Radio Receiver
determined by where the physical stops have been
Manual (available from www.doorking.com) for
installed. It does not matter what position the gate is in
more information on radio receivers and antenna
before running this sequence. The gate will function
installation. (See reverse side for wiring)
normally after this automatic sequence has finished.
Entrapment Protection must be provided for the gate
Note: Auto-close timer should be on
system where the risk of entrapment or obstruction exists.
before running this sequence.
The operator will NOT run without one or more monitored
Automatic Limits
Radio Receiver
m
ini
nd
Co
Key Switch
ON
VO
AM
MA
eP
”
x2
/8” rs
3
4) cho
e(
Us ve An lied).
e
p
Sle t sup
o
(N
SW 1
1. Opening Direction (See Illustration)
2. ON
Auto-Close Timer
3. OFF
4. OFF
1
23
5. OFF
Adjust 1 to
6. OFF
OPEN 23 sec.
7. OFF
TIMER
8. OFF
1 2 3 4 5 6 7 8
E
VERS
REOP
LO
OR
ret
1
ON
SW
FF.
1 2 3 4 5 6 7 8
2
AT
Op
Dir enin
Sw ec g
itch tio
1O n
ON
5338
ER
HP
“Basic” Setting of DIP-Switches
1 2 3 4 5 6 7 8
OP
Chain brackets
MUST be mounted
the same height as
the chain on the
idler wheels!
l
d l!
pa ve
te le
re e
nc T b
Co US
M
GA
TE
L
IAL
SW 1, Switch 1 - Must OPEN the gate upon initial AC
power up and open command. If the open command
begins to close the gate, turn AC power off and
reverse this switch. (See reverse side)
RS
VE
RE OP
LO
DE
10
E IT Y
RS IV
VE IT
RE ENS
S
tion in
n to
pat not stan e.
s. sigh
h whi
play
t
d
in
le in gat
gat
gat
e are
e is e pat
d own
mo h
a
er’s
ving or wal
ma
.
k thro
nua
l and
ugh
safe
ty
inst
ruc
tion
s.
Rea
CO
NF
AN OR
SI/ MS
UL TO
-32
CER
5
N/C TIF
SA IED
C22 TO
.2
HI
NO
CU
. 247
LA
R
SS
MO
SER
49
EN R
OP IME
T
2
SW
G
MO
SE VING
RI
OU GA
Ope
S IN TE
and rate
JU CAN
free gate
RY CA
of onl
Do
OR US
peo y whe
ple
or not allo
DE E
andn gat
ope
AT
rate w chil
obs e are
H
truc a is
Do
gat dre
CLA
Idl
e
Wh r
ee
Chain nut and chain bolt
should not protrude
past gate frame.
r
ste
Ma ink
L
WA
R
VE
A
r
nc
CA
B
re ine
Wi estra
R
Co
NIN
Circuit Board Settings
1
n2
tio
Chain
Nut
Chain
Bolt
H
SW
n
Op
B
ITC
Lo
ele osen
ctr th
oni e 2
c b nu
ox ts u
to
sw nder
ing the
box
up.
tio
Op
SW
NG
KI 18
OR 2-0
DO 60
4
Connect Chain
Bracket
and
Chain
to Gate 1
KEY
Hot
Concrete Pad and Conduit Area
An
IMPORTANT:
Electronic box MUST
be in the down position
and secured for
operator to function.
DANGER
Warning Signs
Permanently mount signs on BOTH sides of the
gate area and make sure they are easily visible.
Copyright 2021 DoorKing®, Inc. All rights reserved.
type B1 or B2 external entrapment protection devices in
EACH direction of gate travel (minimum of 2 external
devices required). See manual for more information.
9100-066-R-1-21
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9100 - DIP-SWITCH AND WIRING REFERENCE
Model 9100 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.
Function
Setting
Opening
direction
using OFF
setting.
Opening
direction
using OFF
setting.
Post
Mounts
Opening
direction
using ON
setting.
Opens
with
Mounts
Left
Mounts
Right
OFF
setting.
Opens
with
ON
setting.
OFF Auto-close timer is OFF. Manual input required to close gate.
ON Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
Auto-Close
Timer
Relay Activation 4-OFF 5-OFF Relay activates and LED is ON when the gate is fully open.
and
4-OFF 5-ON Relay activates and LED is ON when the gate is not closed.
4 and 5
LED Indicator 4-ON 5-OFF Relay activates and LED is ON when the gate is opening and open.
Light Activation
4-ON 5-ON Relay activates and LED is ON when the gate is opening and closing.
OFF Normal Setting.
6
Self-Test
ON Runs self-test. Caution: Bench testing ONLY!
SW 2
1
Exit Loop Port
Output
Setting
Jumper Wire
Needed
See Manual
3
Partial Open
(14 Ft)
4
Built-in
Solenoid
Lock
5
OFF Normal Setting. Switch must be OFF for terminal #5 input to open gate 14 Ft.
ON DO NOT use ON setting. NOT associated with partial open feature for the 9100.
OFF Normal Setting. Fail-safe logic. Lock engages only if attempt is made to force gate
open (Factory setup).
ON Fail-secure logic. Lock engages after each gate cycle (2600-862 Lock kit required).
7 and 8
Gate Close
Back-Off
Position
7-OFF
7-OFF
7-ON
7-ON
8-OFF
8-ON
8-OFF
8-ON
Doo
Normal Setting. Timer will function normally.
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
Normal Setting. Gate fully closes.
Gate stops short 1” from full close position. Used for a reversing edge device.
Gate stops short 2” from full close position. Used for a reversing edge device.
Gate stops short 3” from full close position. Used for a reversing edge device.
ATO
R
PHA
E LOA
rKin
g,
60
D
REVER
P
LOO
SE
SE
Hz
Inc.
, Ing
lew
ood
, CA
T
EXI P
LOO
KEY
EN
OP ER
TIM
H
ITC
SW
G
KIN
OR 0
DO02-01
46
1
2
3
4
5
2
Terminal #3 Note:
Exceeding 250 mA of power from this terminal may cause the circuit
board transformer to overheat, causing intermittent problems.
SE TY
IVI
REVER
SIT
SEN
SW
SW
1
NC
NO
#4-Connected device fully opens gate.
#5-Connected device opens gate 14-feet.
4-Wire 3-Button
Control Station
3-Button Control
Station Jumper 1
Jumper Pins 1 & 2 ONLY when
using a 4-wire control station
to enable stop terminal #7.
2
3
Telephone
Entry
External Entrapment
Protection Devices
Close Beam
Open Edge
Closed Gate
Key Switch
Filler Post If necessary
N
Full Open
SE
Close
E
OP
CLO
OP
ST
Com
1
Common
2
3
4
5
Full Open
6
7
8
9
ENABLE STOP
S 1&2
&2
SHORT PINS
1
2
3
3-Button Control
Station Jumper
DOORKING
UL 325
4602-018 DIP-Switches
1
2
3
4
5
6
13
UL 325 78
14
Terminal 9
10
15
16
17
18 Common
Open Beam
1 - OPEN Beam
2 - Ground (Common)
3 - CLOSE Beam
4 - Ground (Common)
5 - 24 VAC 250 ma. Max
6 - Ground (Common)
7 - OPEN Edge
8 - Ground (Common)
9 - CLOSE Edge
10 - Ground (Common)
Connect ONLY MONITORED
Devices
Stand-Alone
Card Reader
NC
NO
Fire Dept
Open
SW3
SW1
SW2
2-Pin Supplied
Wire Harness
Gate will ONLY OPEN when this device is activated by authorized
personnel ONLY (fire, police, EMS) and operator has power.
Alarm will sound during entire open cycle. Operator will then go
into a hard shutdown once fully opened. Operator MUST be reset
to function normally again. This device MUST be mounted in the
line-of-site of gate so authorized personnel can monitor gate
movement.
UL 325 DIP-Switches
DIP-switches MUST be turned ON for each device wired to terminal.
IMPORTANT: Monitored Photo and
Edge sensors must be end-of-line
resistive types. See specific
manufacturer's wiring manual for
more information.
OPEN
TIMER
Partial Open
10
11
12
Wall
EXIT
LOOP
24 V Power
FULL
ULL OPEN
Full Open
UL 325 Terminal
Stand-Alone
Keypad
Note:
All stand-alone
and telephone
entry devices
must use a
separate power
source.
Stop
IMPORTANT: Only 1 monitored Device can be connected
to each input. An OPTIONAL Expansion Kit (sold
separately) will allow connection for additional devices.
ON
6
Quick-Close
Timer Override
Normal Setting. Switch must be OFF for Model 9100.
DO NOT use ON setting for Model 9100.
ER
HP
AM
PS
MA
X GAT
1 2 3 4
OFF
ON
OFF
ON
Operator Model
Select
24 Volt Com
.
5338
2
OP
VOL
TS
Open Edge
ON
1 2 3 4 5 6 7 8
SW 2
Stops Gate
GA
TE
MO
DEL
Close Edge
OFF Normal Setting. Input to terminal #6 and/or reverse loops will reverse gate
during close cycle.
ON Input to terminal #6 and/or reverse loops will stop gate during close cycle – gate
will continue to close after input to terminal #6 and/or reverse loops are cleared
(Helps prevent tailgating vehicles from unauthorized entry).
Reverses Gate
2
OFF A plug-in exit loop detector plugged into the EXIT Loop port will partially open single
operator or fully open dual operators depending on type of loop detector used).
ON Normal Setting. Plug-in exit loop detector will fully open gate (Single operator).
I/
CAN CER
/CS TIF
A C22IED
VE
.2 TO
HIC
NO
. 247
CLA ULAR
SS
FIRE
Full Open Input
Description
TO
ANS
ON
Function
Relay Com
tion in
pathnot stan .
to
s. sigh
play
whi d
t
in
le in gate
gate
Rea
gate
d own
area
is path
mov
er’s
ing.or walk
man
thro
ual
ugh
and
safe
ty
inst
ruct
ions
ON
Switch
CON
FOR
MS
Entrapment Protection must be provided
for the gate system where the risk of
entrapment or obstruction exists.
The operator will NOT run without one or
more monitored type B1 or B2 external
entrapment protection devices in EACH
direction of gate travel (minimum of 2
external devices required). See manual
for more information.
4-Wire
Receiver
NIN
G
SER
IAL
Normal Setting. Gate fully opens.
Gate stops short 1” from full open position. Used for a reversing edge device.
Gate stops short 2” from full open position. Used for a reversing edge device.
Gate stops short 3” from full open position. Used for a reversing edge device.
Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect.
WA
R
MO
SE VIN
RIO G
US GATE
Ope
INJ CA
and rate
UR N
free gate
Y ORCA
of only
Do
peo whe
US
ple
or not allo
DE E
andn gate
ope
AT
rate w chil
obs area
H
truc is
Do
gate dren
1 2 3 4
8-OFF
8-ON
8-OFF
8-ON
Relay N.O. - #2 - Full Open.
#5 - Opens gate 14-feet.
ON
7 and 8
Gate Open
Back-Off
Position
7-OFF
7-OFF
7-ON
7-ON
24 Volt - 250 mamp. max.
SW 2,
switch 3
must be
OFF.
ON
OFF Normal Setting. No voltage to motor when gate is stopped (Level gate).
ON Voltage applied to motor always. Keeps inclined gate from coasting when stopped.
Motor
Hold
#5 Terminal Note (Single
Operator Only): Any opening
device connected to terminal #5 will
open the gate to the partial open
14-ft setting. External entrapment
protection devices will also open the
gate to the partial open setting. If the
Inherent Reverse Sensor gets
activated during the close cycle, it
SW 2
will always fully open the gate.
24 volt
250 mamp.
max.
ON
3
Mount
All Rear
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
2
Opening
direction
using ON
setting.
All Rear
U.S.A.
#5 - Opens gate 14-feet.
Com
3-Wire Radio
Receiver
ON
1
SW 1
Description
Center or
120 S. Glasgow Avenue
Inglewood, California 90301
Relay - #2 - Full Open.
Changes the direction the operator will open/close the gate depending on the different chain configurations.
Front
Important: Controls intended for user activation must be located at least six (6) feet away from any
moving part of the gate and where the user is prevented from reaching over, under, around or
through the gate to operate the controls. Emergency access controls only accessible by authorized
personnel (e.g., fire, police, EMS) may be placed at any location in the line-of-sight of the gate.
UL 325 LEDs
SW 1
Switch
UL 325 August
2018 Standard
Dual Gate Operators Note: Connect device to BOTH operators,
both gates will fully open.
1 - OPEN Beam (UL 325 Terminal 1)
2 - CLOSE Beam (UL 325 Terminal 3)
3 - OPEN Edge (UL 325 Terminal 7)
4 - CLOSE Edge (UL 325 Terminal 9)
Activation Note: Activation of this device will OPEN gate
regardless of the status of the open direction monitored external
entrapment protection device(s). If gate is opening, and the
operator’s inherent entrapment protection system detects an
obstruction, the operator will reverse approx. 2 inches and go
into a hard shutdown. Operator reset button MUST be pushed to
function again OR cycle operator’s power.
Com