Cal Spas Veranda Spa 2018 Owner's Manual

Cal Spas Veranda Spa 2018 Owner's Manual

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Cal Spas Veranda Spa 2018 Owner's Manual | Manualzz

LTR20181026, Rev. F

5/16/18

Table of Contents

Important Safety Instructions . . . . . . . 1 Cleaning and Maintenance . . . . . . . . . 32

Preparing for Your New Portable Spa . 2

Pre-Delivery Checklist. . . . . . . . . . . . . . . . . . 2

Planning the Best Location . . . . . . . . . . . . . . 2

Preparing a Good Foundation . . . . . . . . . . . . 3

Opening the Front Door Panel for Electrical

Hookup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

240 Volt Electrical Installation . . . . . . . . . . . 4

Wiring Requirement/GFCI Wiring Diagram 5

120 Volt Electrical Installation . . . . . . . . . . . 6

Testing the 240 Volt GFCI Breaker. . . . . . . . 6

Filling and Powering Up Your Portable Spa 6

Priming the Pump . . . . . . . . . . . . . . . . . . . . . 9

Operating Your Spa . . . . . . . . . . . . . . . 10

NEO Control Panel Operation . . . . . . . . . . . 10

Jets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Microsilk Therapy System . . . . . . . . . . . . . . 19

LED Lighting. . . . . . . . . . . . . . . . . . . . . . . . . 20

Diverter Knobs. . . . . . . . . . . . . . . . . . . . . . . 20

Air Venturis . . . . . . . . . . . . . . . . . . . . . . . . . 20

Waterfalls . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Water Clarity . . . . . . . . . . . . . . . . . . . . 21

Water Quality Terms and Definitions

. . . . . 21

Water Testing Methods . . . . . . . . . . . . . . . . 22

Adding Chemicals To The Spa Water . . . . . 23

1. Balancing the Water Chemistry Levels . 23

2. Sanitation and Shock . . . . . . . . . . . . . . . 25

3. Filtration . . . . . . . . . . . . . . . . . . . . . . . . . 26

4. Regularity (Maintenance Schedule). . . . 27

Generic Names for Chemicals . . . . . . . . . . . 27

Common Water Chemistry Questions . . . . 28

Do’s and Don’ts . . . . . . . . . . . . . . . . . . . . . . 29

Bather Load . . . . . . . . . . . . . . . . . . . . . . . . . 30

Pure Cure™ Water Sanitizer . . . . . . . . . . . . 30

Ozonator . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Troubleshooting Water Clarity Problems . . 31

Jet Removal and Replacement . . . . . . . . . . 32

Draining Your Portable Spa . . . . . . . . . . . . 32

Winterizing (Cold Climate Draining) . . . . . 33

Cleaning and Replacing the Filter. . . . . . . . 33

Spa Cover. . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Vacation Care. . . . . . . . . . . . . . . . . . . . . . . . 34

Cleaning Your Spa . . . . . . . . . . . . . . . . . . . . 34

Using the Freedom Sound System . . . . . . . 35

Appendix . . . . . . . . . . . . . . . . . . . . . . . 36

Replacement Parts . . . . . . . . . . . . . . . . . . . 36

Basic Troubleshooting. . . . . . . . . . . . . . . . . 46

“Thermal Creep” . . . . . . . . . . . . . . . . . . . . . 48

Limited Warranty. . . . . . . . . . . . . . . . . . . . . 49

Warranty Registration. . . . . . . . . . . . . . . . . 54

Copyright 2018 LMS. All rights reserved. Duplication without written consent is strictly prohibited.

Cal Spas

®

, Pure Cure

, and Freedom Sound System

are registered trademarks.

Due to continuous improvement programs, all models, operation, and/or specifications are subject to change without prior notice.

LTR20181026, Rev. F

5/16/18

CONTACT INFORMATION

For customer service, please contact your authorized dealer immediately. If you need additional information and/or assistance, contact:

LMS Customer Service Department

1462 East Ninth Street

Pomona, CA 91766.

Toll Free: 1-800-CAL-SPAS

Fax: 1-909-629-3890

Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS.

DANGER -- Risk of accidental drowning:

Do not allow children to be in or around a spa unless a responsible adult supervises them. Keep the spa cover on and locked when not in use. See instructions enclosed with your cover for locking procedures.

DANGER -- Risk of injury:

The suction fittings in this spa are sized to match the specific water flow created by the pump. Should the need arise to replace the suction fittings, or the pump, be sure the flow rates are compatible.

Never operate the spa if the suction fitting or filter baskets are broken or missing. Never replace a suction fitting with one that is rated less than the flow rate marked on the original suction fitting.

DANGER -- Risk of electric shock:

Install the spa at least 5 feet (1.5 meters) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently bonded by a minimum #8 AWG solid copper conductor to the outside of the spa’s control box.

Do not permit any external electrical appliances, such as lights, telephones, radios, televisions, and etc., within five feet (1.5 meters) of the spa. Never attempt to operate any electrical device from inside the spa.

Replace a damaged power cord immediately.

Do not bury the power cord.

Connect to a grounded, grounding-type receptacle only.

WARNING -- To reduce the risk of injury:

The spa water should never exceed 104˚F (40˚C). Water temperatures between 100˚F (38˚C) and 104˚F (40˚C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.

High water temperatures have a high potential for causing fetal damage during pregnancy. Women who are pregnant, or who think they are pregnant, should always check with their physician prior to spa usage.

The use of alcohol, drugs or medication before or during spa use may lead to unconsciousness, with the possibility of drowning.

Persons suffering from obesity, a medical history of heart disease, low or high blood pressure, circulatory system problems or diabetes should consult a physician before using the spa.

Persons using medications should consult a physician before using the spa since some medications may induce drowsiness while others may affect heart rate, blood pressure and circulation.

HYPERTHERMIA DANGER:

Prolonged exposure to hot air or water can induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level 3˚F to 6˚F above the normal body temperature of 98.6˚F (or 2˚C to 4˚C above 37˚C). While hyperthermia has many health benefits, it is important not to allow your body’s core temperature to rise above 103˚F (39.5˚C).

Symptoms of excessive hyperthermia include dizziness, lethargy, drowsiness and fainting. The effects of excessive hyperthermia may include:

• Failure to perceive heat

• Failure to recognize the need to exit spa or hot tub

• Unawareness of impending hazard

• Fetal damage in pregnant women

• Physical inability to exit the spa

• Unconsciousness

WARNING:

The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.

WARNING:

People with infectious diseases should not use a spa or hot tub.

WARNING:

To avoid injury, exercise care when entering or exiting the spa or hot tub.

WARNING:

Do not use a spa or hot tub immediately following strenuous exercise.

WARNING:

Prolonged immersion in a spa or hot tub may be injurious to your health.

WARNING:

Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.

CAUTION

: Maintain water chemistry in accordance with manufacturer’s instructions.

SAVE THESE INSTRUCTIONS.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

1

2

Preparing for Your New Portable Spa

Pre-Delivery Checklist

Most cities and counties require permits for exterior construction and electrical circuits. In addition, some communities have codes requiring residential barriers such as fencing and/or self-closing gates on property to prevent unsupervised access to the property by children. Your dealer can provide information on which permits may be required and how to obtain them prior to the delivery of your spa.

Before Delivery

Plan your delivery route

Choose a suitable location for the spa

Lay a 5 - 8 cm concrete slab

Install dedicated electrical supply

After Delivery

Place spa on slab

Connect electrical components

Planning the Best Location

Safety First

Do not place your spa within 10 feet (3 m) of overhead power lines.

Provide a View with Your Spa

Consider How You Will Use Your Spa

How you intend to use your spa will help you determine where you should position it. For example, will you use your spa for recreational or therapeutic purposes? If your spa is mainly used for family recreation, be sure to leave plenty of room around it for activity. If you will use it for relaxation and therapy, you will probably want to create a specific mood around it.

Think about the direction you will be facing when sitting in your spa. Do you have a special landscaped area in your yard that you find enjoyable? Perhaps there is an area that catches a soothing breeze during the day or a lovely sunset in the evening.

Keep Your Spa Clean

In planning your spa’s location, consider a location where the path to and from the house can be kept clean and free of debris.

Prevent dirt and contaminants from being tracked into your spa by placing a foot mat at the spa’s entrance where the bathers can clean their feet before entering your spa.

Plan for Your Environment

If you live in a region where it snows in the winter or rains frequently, place the spa near a house entry. By doing this, you will have a place to change clothes and not be uncomfortable.

Consider Your Privacy

In a cold-weather climate, bare trees won’t provide much privacy. Think of your spa’s surroundings during all seasons to determine your best privacy options. Consider the view of your neighbors as well when you plan the location of your spa.

Allow for Service Access

Make sure the spa is positioned so that access to the equipment compartment and all side panels will not be blocked.

Many people choose to install a decorative structure around their spa. If you are installing your spa with any type of structure on the outside, such as a gazebo, remember to allow access for service. It is always best to design special installations so that the spa can still be moved, or lifted off the ground.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Preparing a Good Foundation

Your spa needs a solid and level foundation. The area that it sits on must be able to support the weight of the spa, with water and the occupants who use it. If the foundation is inadequate, it may shift or settle after the spa is in place, causing stress that could DAMAGE YOUR

SPA SHELL AND FINISH.

Damage caused by inadequate or improper foundation support is not covered by the warranty. It is the responsibility of the spa owner to provide a proper foundation for the spa.

Place the spa on an elevated 3 to 4” / 30 cm concrete slab.

Pavers, gravel, brick, sand, timbers or dirt foundations are

not

adequate to support the spa.

We strongly recommend that a qualified, licensed contractor prepare the foundation for your spa.

If you are installing the spa indoors, pay close attention to the flooring beneath it. Choose flooring that will not be damaged or stained.

If you are installing your spa on an elevated wood deck or other structure, it is highly recommended that you consult a structural engineer or contractor to ensure the structure will support the weight of 150 pounds per square foot

(732 kg / m2).

To properly identify the weight of your new spa when full, remember water weighs 8.33 lbs. per gallon, or 1 kg per liter. For example, an average 8’ spa holds approximately

500 gallons, or 1892 liters, of water. Using this formula, you will find that the weight of the water alone is 4,165 lbs, or

1892 kg. Combined with the dry weight of the spa you will note that this spa will weigh approximately 5,000 lbs, or

2267 kg, when full of water.

3

Opening the Front Door Panel for Electrical Hookup

The following electrical connections must be performed by a licensed electrical contractor.

Unscrew and remove the two corner panels on each side of the spa’s front door.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

4

Reach in and pull the drain assembly through by a few inches. Carefully unscrew the black outer drain knob and then unscrew and remove the front door panel.

Pictured to the right is the inside of the spa behind the front door. The electrician now has access to connect the spa for power. While the front door is off, refer to page 6 for instructions on ensuring the plumbing fittings are secure

(but do not be tempted to over-torque or over-tighten these fittings).

Pull the drain pipe through the front door panel, reattach the black outer drain knob and pull the drain assembly back inside so that the knob is flush with the panel again. Reattach and screw panels back in. (Front door first, then corner panels)

240 Volt Electrical Installation

All 240V spas must be permanently connected (hard wired) to the power supply. See the GFCI and wiring requirements on page 5.

These instructions describe the only acceptable electrical wiring procedure. Spas wired in any other way will void your warranty and may result in serious injury.

When installed in the United States, the electrical wiring of this spa must meet the requirements of NEC 70 and any applicable local, state, and federal codes.

The electrical circuit must be installed by an electrical contractor and approved by a local building or electrical inspector.

www.calspas.com

Failure to comply with state and local codes may result in fire or personal injury and will be the sole responsibility of the spa owner.

The power supplied to the spa must be on a dedicated

GFCI protected circuit as required by NEC 70 with no other appliances or lights sharing the power.

Use copper wire with THHN insulation. Do not use aluminum wire.

Use the table below to determine your GFCI and wiring requirements.

Wires that run over 100 feet must increase wire gauge to the next lower number. For example: A normal 50 amp

GFCI with four #6 AWG copper wires that run over 100 feet would require you to go to four #4 AWG copper wires.

2018 Portable Spa

LTR20181026, Rev. F

Wiring Requirement/GFCI Wiring Diagram

Control System

NEO 1500 (one pump system)

GFCI Required

One 40 amp GFCI

Wires Required

Four #8 AWG copper wires

5

See the Cal Spas Pre-Delivery Guide for more information on spa placement for service access and electrical service.

www.calspas.com/manuals

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

6

120 Volt Electrical Installation

Always follow applicable local, state and federal codes and guidelines.

Use only a dedicated electrical line with a 15 amp breaker.

Cord-and-plug connections may not use a cord longer than 15 feet (4.6 m) and must be plugged into a dedicated 15 amp GFCI connection (NEC 680.42(A)

(2)). Do not use extension cords!

Always use a weatherproof-covered receptacle.

Receptacle shall be located not less than 5 feet (1.5 m) from and not exceeding 10 feet (3.0 m) from the inside wall of the spa. (NEC 680.43(A))

Do not bury the power cord. If your cord becomes damaged, replace it before next usage.

All 120V spas must have a GFCI. This can be either a

15 amp GFCI receptacle or a 15 amp GFCI cord and plug kit as shown (CKIT110 - P/N ELE09700086).

Testing the GFCI plug

Test the GFCI plug prior to first use and periodically when the spa is powered.

1. Plug in the GFCI into the power outlet. The indicator should turn on.

2. Press the TEST button.

The GFCI will trip, the indicator will turn off, and the spa will stop operating.

3. Press the RESET button. The GFCI will reset, the indicator will turn on again, and the spa will turn back on.

The spa is now safe to use.

If the GFCI trips while the spa is in use, press the RESET button.

If the GFCI does not reset, unplug the spa and call your local Cal

Spas dealer for service. DO NOT USE THE SPA!

Testing the 240 Volt GFCI Breaker

Test the GFCI breaker prior to first use and periodically when the spa is powered. To test the GFCI breaker follow these instructions (spa should be operating):

1. Press the TEST button on the GFCI. The GFCI will trip and the spa will shut off.

2. Reset the GFCI breaker by switching the breaker to the full OFF position, wait a moment, then turn the breaker back on. The spa should have power again.

Filling and Powering Up Your Portable Spa

1. Inspect the spa equipment.

Inspect all plumbing connections in the equipment area of your spa.

• Make sure unions in the equipment pack are tight. (Be careful not to over-tighten the plumbing fittings.)

• If your spa has gate valves, make sure they are all in the UP or OPEN position.

• Make sure the drain valve is closed and capped. (See page 32 for a description of drain valves.)

www.calspas.com

Never run the spa with the gate valves closed or without water circulating for long periods of time.

2018 Portable Spa

LTR20181026, Rev. F

2. Remove the cartridge from filter canister.

For your skimmer like this:

Rotate and remove the black locking ring. Remove the black skimmer cap and barrel, grip the filter by the handle and unscrew it from the canister. Replace and lock the locking ring and slide the skimmer cap and barrel back in the canister.

Note: The skimmer cap and barrel were locked in place at the factory to prevent damage during shipment. It must be unlocked and replaced in the filter canister so that it can float when the spa is filled. If you do not remove the cap and barrel, your spa’s filtration system will not perform as it was designed to.

Teleweir filter skimmer

• 50 square feet filtration

• Spoked cap

7

After you remove the filter, remove the plastic wrapper and soak it in water for 30 minutes before you replace it. A dry filter can allow air into the filtration system which can cause the pump to fail to prime.

3. Fill the spa.

Place a garden hose in the filter canister and fill your spa

.

Always fill the spa through the filter canister.

Failure to do so may cause air to be trapped in the filtration system and prevent the pumps from operating properly.

Fill the spa until water level is about six inches from the top.

If the water level is too low or too high, your spa will not operate properly.

Never fill your spa with soft water.

Soft water makes it impossible to maintain the proper water chemistry and may cause the water to foam, which will ultimately harm the finish of the spa and void your warranty.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

8

4. Turn on power to the spa.

When the spa is filled to the correct level, turn on the power at the GFCI breaker. (Ensure that the 120V spas are connected to the proper electrical outlet.)

5. Prime the pump.

The system will enter the priming mode.

Priming Mode

will display on the control panel. In Priming Mode, all devices such as jets and lights are operable. Jets can be turned on and off to help prime the pump. The system will exit Priming Mode and go to the Main display when the RETURN button is pressed, or after four minutes of inactivity.

6. Install the filter into the filter canister.

Make sure the filter has soaked at least 30 minutes before you install it.

7. Adjust water chemistry.

Test and adjust the water chemistry. See the section on page 21 for instructions on keeping your water clear.

8. Let the spa heat up.

When the spa has finished priming, the heater will activate. Put the cover on and let the spa heat to the set temperature.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Priming the Pump

New spa owners often have difficulty the first time they start their spa and the pump fails to prime. This can be frustrating, but these simple instructions can help you.

Sometimes air can become trapped in the pump while filling the spa. You will know this has happened when after you have filled and started the spa,

The pump will not work properly while air is trapped in it.

Continuing to operate the pump in this way will cause damage.

the pump does not seem to function. You will hear the pump operating, but no water will be moving.

Starting Up: Priming Mode for NEO-Pack Systems

The system will enter the priming mode.

Priming Mode

will display on the control panel. In Priming Mode, all devices such as jets and lights are operable. Jets can be turned on and off to help prime the pump. The system will exit Priming Mode and go to the Main display when the RETURN button is pressed, or after four minutes of inactivity.

9

Exiting Priming Mode for NEO-Pack Systems

If you have tried priming the pump several times unsuccessfully using the control panel, you can bleed the air from the pump manually.

Bleeding Air from the Pump

1. Shut off the power to the spa.

2. Using a Phillips screwdriver, remove the front panel from the spa and locate the pump.

3. Close the gate valve on the discharge side of the pump (if your spa is installed with one.)

4. Turn the bleeder valve counter clockwise with a small pair of pliers until the air has been released from the pump.

5. If this is unsuccessful, loosen the union nut on side of the pump with channel locks. When air is bled out, tighten the nut.

6. Turn on power to the spa and press the

JETS

button. If there is still air trapped in the pump, repeat steps 2 through 5 until the pump primes.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

10

Operating Your Spa

NEO Control Panel Operation

Primary Navigation and Functions

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

11

12

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Settings Screens

13

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

14

Error Screens

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Other Spa Systems

Several spa functions operate in the background and require no action or maintenance from you. This is for your information only.

Pumps

Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low- and high-speeds if equipped. If left running, the pump will turn off after a time-out period.

The pump 1 low-speed will time out after 30 minutes. The high-speed will time out after 15 minutes.

On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in Ready

Mode, Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa temperature (polling) and then to heat to the set temperature if needed. When the low-speed turns on automatically, it cannot be deactivated from the panel, however the high speed may be started.

Circulation Pump

The circulation pump will come on when the system is checking temperature (polling), during filter cycles, during freeze conditions, or when another pump is on.

The ozonator will run with the circulation pump during filtration cycles.

Purge Cycles

In order to maintain sanitary conditions, secondary Pumps and/or a Blower will purge water from their respective plumbing by running briefly at the beginning of each filter cycle.

15

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

16

Operating the NEO Wi-Fi App

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

17

18

Connecting to a Device or Network

1

Direct connection

Range: About 20 feet

Range limit: Limited to the range of the wi-fi module

HOW TO CONNECT TO IT:

Install the app on your phone or device -- see the following section “Installing the app”.

2

Through home network with no internet access

Allows one local connection at a time

Range: About 50 feet

Range limit: Limited to the range of your home router’s signal

HOW TO CONNECT TO IT:

1. Install the app on your phone or device.

2. Exit the app and go to wi-fi settings on your phone or device.

3. Select and enable your local router.

4. Start the app. After you connect, select Settings on the home screen.

5. On the Settings screen, select Advanced, then on the Advanced screen, select Wi-fi Settings.

6. On the Wi-fi screen, select WPA. Then select the name of your home router from the drop-down menu.

7. Enter the SSID and Key for your router, the tap Save and select OK twice.

8. Close the app and re-start it to connect to your home network.

3

Through a network with internet access, using

Cloud connection or other hotspot connection

Allows unlimited simultaneous connections

Range: Worldwide

Range limit: Limited to 3G / 4G / hotspot availability

HOW TO CONNECT TO IT:

Follow connection instructions from section (2) above. The Cloud icon appears automatically when network connection is made. You can then connect to the spa’s wi-fi module.

Internet

Local hotspot

3G or 4G

Wi-fi

Your spa

Wi-fi signal

Phone or other device

Your home network router

Internet cloud connection

Local wi-fi connection

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

For More Information

If you have any trouble connecting, you can find more in-depth instructions at the Balboa Water Group web site at www.

balboawatergroup.com/bwa and download the PDF document “Setting Up Your Wi-Fi”.

There are also installation and setup videos at www.youtube.com/user/balboawatergroup.

19

Jets

Almost all of the jets in your spa are adjustable. Rotating the face of an adjustable jet to the left (counterclockwise) will decrease the amount of water flow through the jet. Rotating the face of an adjustable jet to the right

(clockwise) will increase the amount of water flow through the jet. (See example shown here.)

Neck jets adjust in the opposite directions (counterclockwise to increase, clockwise to decrease).

Jets

Microsilk Therapy System

Aux

The optional Microsilk feature is available with the V-422B spa only.

The Microsilk system generates microbubbles that are 50 to 100 times smaller than ordinary air bubbles. The microbubbles are oxygen-rich and help hydrate your skin.

Warm Cool Light

it will turn white to create an ideal Microsilk environment.

The Microsilk pump will run for 15 minutes or until you press

Aux

to turn it off. When the pump cycle finishes, you can press

Aux

to start the Microsilk pump again.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

20

LED Lighting

Press the LIGHT button on the topside control panel to turn the spa light on. If your spa has perimeter LED lights, they will also light up at the same time as the spa light.

The LEDs operate in three modes:

1. Cycle:

When you continually press the LIGHT button, the LEDs will cycle through the three main LED colors

(Red, Green, and Blue) or combinations of the three that produce the following colors: light green, purple, light blue, yellow, etc.

Each time you press the button, you immediately advance to the next color in sequence or eventually a different light pattern.

2. Flashing:

When you are cycling through all the colors, the next time you push the LIGHT button, the

LED lights may start flashing. This is another normal operational pattern option.

3. Fading cycle:

The next phase of operation when you push the LIGHT button is a slow and/or fast fade random transition from one color to the next.

• If a spa is equipped with more than 100 points of light, the Slow Fading Cycle will flicker during a color change.

• Every air valve and water valve is equipped with 4 LED points.

• Every jet is equipped with 2 LED points.

• Perimeter LEDs take 9 points of light.

• The waterfall takes 4 points of light.

Spas with exterior corner LED lighting generally work in the same mode as described above. The variations in color and patterns provide you with multiple options to suit almost any lighting preference.

Diverter Knobs

Diverter knobs are 1” and 2” knobs located around the top of your spa. They allow you to divert water through jets from one side of the spa to the other, or in most cases from floor jets to wall jets. This is accomplished by rotating the diverter knob to the left (counterclockwise), decreasing the amount of water flow through a section of jets. To increase the amount of water flow through the other section of jets, rotate the handle to the right (clockwise).

Air Venturis

Air venturis are the 1” knobs located around the top of your spa. Each one will let you add a mixture of air with the jet pressure. This is accomplished by rotating the air venturi knob to the left (counterclockwise) to increase the amount of airflow through the jets. To decrease the amount of airflow through the jets, rotate the handle to the right (clockwise).

Waterfalls

This spa series includes an optional waterfall. To turn on the waterfall, press Jets and make sure the diverter valve is on. Press Jets again to turn the waterfall off.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Water Clarity

This section is intended for new spa owners with no experience with water chemistry. Everyone’s experience with maintaining water quality is different, but there are some general concepts you need to know.

Water maintenance is not difficult, although it requires regular attention. The most important thing to understand about taking care of your spa water is that preventive action is much easier than correcting water quality issues.

1

Chemical Balance

See page 23 to learn how to balance your spa water.

You will need to test and adjust the chemical balance of your spa water. Although this is not difficult, it needs to be done regularly.

You need to test the level of calcium hardness, total alkalinity, and pH.

Spa owners with a bromine generator also need to check total dissolved solids and phosphates.

3

Filtration

See page 26 for filter cleaning instructions.

Cleaning your filter regularly is the easiest and most effective single thing you can do to keep your water clear.

A clogged or dirty filter will cause the heater and pump to work harder than they need to, possibly causing them to fail.

The spa’s heating system will only function with the proper amount of water flow through the system.

Before you begin, we recommend you become familiar with some water quality terms and their definitions (see next page).

Whether you’re filling your spa for the first time (see page

6) or refilling it after draining it for regular maintenance (see page 32), start and maintain your spa water by following the plan we describe in this section.

2

Sanitation and Shock

See page 25 to learn how to use sanitizer and shock.

Sanitizers kill bacteria and viruses and keep the water clean. A low sanitizer level will allow microbes to grow quickly in the spa water. We recommend using either chlorine or bromine as your sanitizer.

You also need to add shock to the water to stimulate the chemical sanitizer. How much you use and how often depend on frequency and intensity of use.

Spa owners with an ozonator also need to add sanitizer, although their requirements are different.

4

Regularity

See page 27 for the schedule of recommended maintenance.

Clear water requires regular maintenance. Establish a routine based on a regular schedule for your spa water maintenance.

Maintaining your water quality helps the enjoyment of your spa and extends your spa’s life by preventing damage from neglect and chemical abuse.

Water Quality Terms and Definitions

The following chemical terms are used in this section. Understanding their meaning will help you to better understand clear water maintenance. Words in bold type are defined in this table.

Bromine /

Bromamines

Chlorine /

Chloramines

Bromine is an efficient sanitizer chemical for spas. When used as a

sanitizer

, bromine forms compounds called bromamines. Bromine can be added to the spa or automatically generated. See page 25 for discussion on

sanitizers

.

Bromamines are compounds formed when bromine combines with nitrogen from body oils, perspiration, etc. Unlike chloramines, bromamines have no pungent odor and are effective

sanitizers

.

Chlorine is an efficient sanitizing chemical for spas. We recommend using sodium dichlor-type granulated chlorine because it is totally soluble and nearly

pH

neutral. When used as a

sanitizer

, chlorine forms compounds called chloramines. See page 25 for discussion on

sanitizers

.

Chloramines are compounds formed when chlorine combines with nitrogen from body oils, perspiration, etc. Chloramines can cause eye irritation as well as having a strong odor. Unlike

bromamines

, chloramines are weaker, slower

sanitizers

. To remove chloramines, see the description of

shock

below.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

21

22

Calcium Hardness

Abbreviated as CH. Calcium hardness is a measure of the total amount of dissolved calcium in the water. Calcium helps control the

corrosive

nature of the spa’s water and is why soft water is not recommended. The low CH level can cause

corrosion

to the equipment and can cause staining of the spa shell. See page 24 for testing for and balancing calcium hardness.

Corrosion

The gradual wearing away of metal spa parts, usually caused by chemical action. Generally, corrosion is caused by low

pH

or by water with levels of

TA

,

CH

,

pH

or sanitizer which are outside the recommended ranges.

Dichlor

Monopersulphate or MPS

Oxidizer

Also called sodium dichlor. It is a type of chlorine and is frequently used when

shocking the water

. An effective

chlorine

-based powdered

oxidizer

and

sanitizer

. Dichlor works by oxidizing waste product in the water such as

bromamines

and

chloramines

and causing them to burn off.

Frequently used when

shocking the water

. An effective non-chlorine-based powdered

oxidizer

that works well with both

chlorine

and

bromine

. It works by oxidizing waste product in the water such as

bromamines

and

chloramines

and causing them to burn off.

Shocking the water

with an oxidizing chemical prevents the buildup of contaminants, maximizes

sanitizer

efficiency, minimizes combined

chlorine

and improves water clarity.

Ozone pH

Ozone is a powerful oxidizing agent which is produced in nature and artificially. Ozone forms no by-products of

chloramines

(ozone actually oxidizes chloramines) and will not alter the water’s

pH

.

The pH level is the measure of the balance between acidity and alkalinity. Low pH causes the water to be too acid, which will cause

corrosion

, whereas high pH causes the water to be too alkaline, which will cause

scaling

. See page 24 for testing for and balancing pH.

ppm

Sanitizer

Scale

The abbreviation of “parts per million”, the standard measurement of chemical concentration in water. Identical to mg/l (milligrams per liter).

Sanitizer is a chemical added to the water to kill bacteria and viruses and keep the water clean.

The two sanitizers we recommend are

chlorine

and

bromine

. See page 25 for discussion of sanitation.

Rough calcium-bearing deposits that can coat spa surfaces, heaters, plumbing lines and clog filters. Generally, scaling is caused by mineral content combined with high

pH

. Additionally, scale forms more readily at higher water temperatures.

Shock

Total Alkalinity

Trichlor

Also called shocking the water, shock treatment, or superchlorination. Shocking the water is adding significant doses of

dichlor

or

MPS

to

oxidize

non-filterable organic waste and to remove

chloramines

and

bromamines.

Shock treatment breaks down organic waste contaminants which cause odor and cloudy water. See page 26 for discussion of shocking the water.

Abbreviated as TA. Total alkalinity is the measure of the total levels of carbonates, bicarbonates, hydroxides, and other alkaline substances in the water. TA is important for

pH

control. If the TA is too low, the

pH

will fluctuate out of control, and if it is too high, the

pH

becomes difficult to stabilize. See page 23 for testing for and balancing total alkalinity.

Used as a pool

sanitizer

. NEVER use trichlor in a spa. Trichlor is extremely acidic and will lower the

pH

, causing corrosion to equipment. Using trichlor will void your warranty.

Water Testing Methods

There are two testing methods to choose from:

Test strips are a convenient testing method commonly used by spa owners.

The reagent test kit is a method which provides a high level of accuracy but is more expensive and more difficult to use.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Adding Chemicals To The Spa Water

IMPORTANT:

All spa water chemicals, including MPS (shock), chlorine, granulated pH increaser or decreaser, granulated total alkalinity increaser, calcium hardness increaser, liquid stain and scale inhibitor, and liquid de-foamer must always be added directly into or in front of the filter compartment while a jet pump is running, and it must run for a minimum of ten minutes.

1. Fold back the cover.

2. Press the

Jets

or

Jets 1

button.

3. Carefully measure the recommended amount of chemical and slowly pour it into the filter area. Use care not to splash chemicals on your hands, in your eyes, on the spa surface, or on the siding.

4. Close the spa cover.

Warning:

High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended range before using the spa.

IMPORTANT NOTE REGARDING SHOCK TREATMENT:

After administering shock to your spa, leave the cover open for a minimum of 20 minutes to allow the oxidizer gas to vent. A high concentration of trapped oxidizer gas which may exist as a result of the shock treatment (not daily sanitation) may eventually cause discoloration or vinyl degradation to the bottom of the cover. This type of damage is considered chemical abuse and is not covered under the terms of the limited warranty.

1. Balancing the Water Chemistry Levels

Maintaining spa water chemistry can be tricky, especially since there are many methods of keeping your water clear and clean. Follow the maintenance schedule on page 27 to determine how often you should test your water.

We do not recommend any brand of chemical. See page 27 for a table of common chemicals used in spas and their generic equivalents.

See a spa dealer for guidance and recommendations on spa chemicals and supplies. Various chemicals often sold under brand names, but a spa dealer can advise you on generic chemicals that are often much less costly than proprietary brands.

Balancing the Total Alkalinity (TA)

Total Alkalinity is a measure of the total levels of carbonates, bicarbonates, hydroxides, and other alkaline substances in the water.

TA is referred to as the water’s “pH buffer”. In other words, it’s a measure of the ability of the water to resist changes in pH level.

TA too high

pH will be too high and may be difficult to stabilize pH

180

160

140

Add an alkalinity decreaser

If the TA is too low, the pH level will fluctuate widely from high to low. Fluctuations in pH can cause corrosion or scaling of the spa components. Low TA can be corrected by adding sodium carbonate

(pH/Alkalinity Up).

TA balance

120

100

80

Ideal TA balance

If the Total Alkalinity is too high, the pH level will tend to be high and may be difficult to bring down. It can be lowered by using sodium bisulfate(pH/Alkalinity Down).

TA too low

pH will fluctuate wildly

60

40

20

Add an alkalinity increaser

Once the TA is balanced, it normally remains stable, although the addition of more water with a high or low alkalinity will raise or lower the TA reading of the water.

Causes scale to deposit on spa and

When the Total Alkalinity is within the recommended range, proceed to the next step.

275

250

225

Dilute the spa with soft water

200

CH balance

175

150

Ideal CH balance

2018 Portable Spa

LTR20181026, Rev. F

CH too low

Causes equipment corrosion

125

100

75

Add a calcium hardness increaser

www.calspas.com

pH too high

Too alkaline, causes scaling

pH balance pH too low

Too acidic, causes corrosion

7.2

7.0

6.8

6.6

8.2

8.0

7.8

7.6

7.4

Add a pH decreaser

Ideal pH balance

Add a pH increaser

23

24

TA too high

pH will be too high and may be difficult to stabilize pH

TA balance

180

160

140

120

100

80

Add an alkalinity decreaser

Ideal TA balance

Balancing the Calcium Hardness (CH)

Calcium Hardness is a measure of the total amount of dissolved calcium in the water. Calcium helps control the corrosive nature of the spa’s water. That’s why calcium-low water (commonly known as “soft” water) is not recommended. It is very corrosive to the equipment, and can cause staining of the spa shell.

If the CH is too high (commonly known as “hard water”), formation of scale on the spa’s shell surface and equipment can result. You can use a generic calcium remover to remove hardness from water. CH can also be decreased by dilution – a mixture of 75% hard and 25% soft water will usually yield a reading within the correct range. If soft water is not available or practical for you, a stain and scale inhibitor should be added to the spa water, according to label instructions.

If the CH is too low add CH Increaser.

Balancing the pH

8.0

Add an alkalinity decreaser

Dilute the spa with soft water

Ideal TA balance

Dilute the spa with soft water

Add a pH decreaser

Once the CH is balanced, it normally remains stable, although the addition of more water with a high or low calcium content will raise or lower the CH reading of the water.

When the CH is within the recommended range, proceed to the next step.

The pH level is the measure of acidity and alkalinity. Values above

7.8 are alkaline; those below 7.2 are acidic. Maintaining the proper pH level is extremely important for optimizing the effectiveness of the sanitizer, maintaining water that is comfortable for the user, and preventing equipment deterioration.

If the spa water’s pH level is too low, the following may result:

• The sanitizer will dissipate rapidly.

The water may become irritating to spa users.

The spa’s equipment may corrode.

TA too low

pH will fluctuate wildly

TA too high

and may be difficult to stabilize pH deposit on spa and

TA balance

CH balance

TA too low

pH will fluctuate wildly

Causes equipment

CH too high

deposit on spa and

Too alkaline, causes scaling

CH balance pH

CH too low

Too acidic, causes corrosion

pH too high

Too alkaline, causes scaling

pH balance pH too low

Too acidic, causes corrosion

60

40

200

175

150

125

250

225

7.6

7.4

7.2

7.0

8.0

7.8

7.6

7.4

7.2

7.0

6.8

6.6

Add an alkalinity increaser

Ideal CH balance

Add an alkalinity increaser

Add a calcium hardness increaser

Ideal CH balance

Ideal pH balance

Add a calcium hardness increaser

Add a pH increaser

Add a pH decreaser

Ideal pH balance

Add a pH increaser

If the pH is too low, it can be increased by adding sodium hydrogen carbonate (pH/Alkalinity Up) to the spa water.

If the pH level is too high, the following may result:

• The sanitizer is less effective.

• Scale will form on the spa shell surface and the equipment.

• The water may become cloudy.

• The filter cartridge pores may become obstructed.

If the pH is too high, it can be decreased by adding sodium bisulfate (pH/Alkalinity Down) to the spa water.

NOTE: After adding sodium hydrogen carbonate or sodium bisulfate, wait two hours before testing the water for pH.

Measurements taken too soon may not be accurate.

It is important to check the pH on a regular (weekly) basis. The pH will be affected by the bather load, the addition of new water, the addition of various chemicals, and the type of sanitizer used.

When the pH is within the recommended range, proceed to sanitation.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

2. Sanitation and Shock

Sanitizers kill bacteria and other organic waste by breaking them down to non-harmful levels which are filtered out.

Before you fill your spa, you need to decide which chemical sanitizer you wish to use. Consult your Cal Spas dealer for the right decision with regards to your lifestyle and spa usage.

We recommend either

bromine

or

chlorine

as your sanitizer. Both work well when maintained regularly.

DO NOT use Trichlor. Trichlor is very acidic and the hot temperature of the spa causes it to dissolve too quickly. It will cause damage to your spa and will void your warranty.

Whichever plan you decide on, follow it completely and don’t take shortcuts. It will provide you with clean, safe, clear spa water with a minimum of effort. Spa owners with an ozonator still need to use a chemical sanitizer. See page 30 for a description of how the ozonator works.

Whenever you test your chemical levels, your test strip will likely have a test for chlorine or bromine. Make sure your sanitizer falls within the range shown below.

Testing For:

Chlorine Level

Without ozonator

With ozonator

Bromine Level

Without ozonator

With ozonator

Ideal Range (ppm)

Minimum Maximum

3.0 5.0

2.0 4.0

6.7 11.0

5.7 10.0

Starting and Maintaining Sanitizer Levels

Sanitizing your spa with chlorine or bromine is very similar.

Each sanitizer has its advantages and disadvantages.

Starting with fresh water:

Bromine:

Whereas chlorine can sometimes cause offensive odors and skin irritation, bromine is less likely to do so. Additionally, unlike chlorine, when bromine combines with bather waste and other contaminants in the water, it remains a very effective sanitizer. Bromine is also far less pH-dependent than chlorine.

Always remember that bromine by itself is not a sanitizer, and it needs to be activated by shock in order to be effective.

1. Establish a baseline by adding either granulated chlorine or bromine.

• Use half an ounce of chlorine for every 500 gallons of water.

• Use half an ounce of bromine for every 100 gallons of water.

2. Run the jets for 10 minutes.

3. Test the water. Make sure the pH, TA, and CH levels all fall within the ranges shown on the previous page.

Make adjustments where they are needed.

Chlorine:

The most commonly recognized sanitizer is chlorine. However, the effectiveness of chlorine depends heavily on the pH level of the spa water. In order to get the most effective and economical benefit of chlorine, you must maintain a consistent pH level of between 7.2 to 7.6.

A disadvantage of using chlorine is that when chlorine combines with bather waste and other contaminants in the water, not only does it lose its sanitizing ability, it can cause odors and irritate eyes and skin.

4. At this point, if you use bromine, it is not yet activated and

it will not sanitize the water

. You need to shock-oxidize the spa water. Depending on the size of your spa, add one to two ounces of shock. You can use any kind of shock you want.

5. Test the water again. When the water is balanced, your spa is ready to use.

After you choose a sanitizer, you will need to establish a baseline and maintain it regularly.

Note: If you choose to use bromine, we do not recommend using a floater. You have more control over the bromine level by adding bromine as needed. For more discussion on this, see page 28, “Common Water Chemistry Questions”.

25

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

26

Shocking the Water

In addition to using a chemical sanitizer, you will periodically need to shock the water. Shocking helps refresh the water by breaking down organic waste contaminants which cause odor and cloudy water. After treatment, water quality and clarity is often completely restored.

The two types of shock are sodium dichlor and potassium monopersulfate (MPS). You can use either type of shock regardless of which sanitizer you use. Even if you use bromine, you can use a chlorinated shock if you wish -- in fact, you may find a chlorinated shock is more effective than dichlor or MPS alone.

If irritating chloramines are present, shocking also converts them back to active chlorine. If you use bromine sanitizer, shocking activates the bromide ion (which by itself has no disinfecting capability) which becomes hypobromous acid in water, a good sanitizer.

Add one ounce of oxidizer shock once a week, after heavy bather loads, or if water has a strong odor.

Spa must be running with all of the jets on high for 30 minutes with the cover open. If necessary, repeat shock in

30 minute intervals.

3. Filtration

The filter is the part of your spa that removes the debris from the water and needs to be cleaned on a regular basis to maximize your spa’s filtering performance and heating efficiency.

It is extremely important that you never run the spa without a filter. There is a possibility that debris may be sucked into the plumbing through the filter well.

Changing the Default Filtration Setting

See page 13 for instructions on using the control panel to change filtration settings.

When your spa is first powered up, the filtration setting defaults to the factory setting, which is one two-hour filtration cycle per day. This is adequate for light to moderate usage (see the topic “Bather Load” on page 30), but if you use your spa frequently or have a large number of people using it, you will need to increase the filtration.

You have two filtration cycles available, although the second one is off by default. You can turn the second cycle on if you want additional filtration time, or if you want to divide the filtration times. You can also set filter cycles 1 and 2 for different durations if you wish. Some spa owners set a long second filtration cycle to run at night when electrical power rates are lower.

If you set the spa in READY Mode (see page 13), the circulation pump will run as the spa maintains the set temperature.

However, if you set it to REST Mode, the spa will heat only during filtration cycles. If this is the case, if you use the spa in the last afternoon, you may want to set the first filter cycle to run a few hours before you use it so the water will be warm.

We recommend you trying different times and durations for the filter cycles until you find a filtration plan that works for you.

Cleaning the Filter

In addition to spraying off the filter weekly to remove surface debris, your filter should be deep cleaned periodically to dissolve scale and particles that get lodged deep within the filter fibers and impede the filtration process. Even if the filter looks clean, scale and particles can clog the fibers and prevent water from flowing through the filter resulting in the most common spa problem—no heat, caused by a dirty filter.

We recommend you clean your filter at least once a month, possibly every two weeks depending on how frequently you use your spa, and replace it once a year or as necessary. See page 33 for instructions on removing and cleaning the filter.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

4. Regularity (Maintenance Schedule)

Prior to each use

Test the spa water. Adjust chemical levels as necessary.

Shock the water by adding ½ teaspoon of sodium dichlor per 250 gallons or 1 teaspoon of MPS per 250 gallons.

After each use

Once a week

Add an ounce of oxidizer after heavy bather loads (see page 26 on shocking the water).

Check the filter well and inside the filter pipe for leaves and foreign matter.

Every two to four weeks

Every two to four months

Test the spa water. Adjust chemical levels as necessary.

Shock the water by adding ½ teaspoon of sodium per 250 gallons or 3 teaspoons of

MPS per 250 gallons.

If your water source is high in calcium, add stain and scale preventer.

Deep clean your spa’s filter (see page 33). How often you clean your filter depends on how much you use your spa. There is no harm in frequently cleaning your filter and will only help your spa’s efficiency.

Change the spa water. How often you change the water depends on how much you use the spa. When you change the water, you will need to:

• Clean and polish the acrylic surface (see page 34)

• Clean and treat the spa cover and pillows (see page 34)

• Deep clean the filter (see page 33)

• Refill your spa (see page 6)

Each time you refill the spa

Follow the section “Filling and Powering Up Your Portable Spa” on page 6

.

Once a year

Replace filter cartridges if the pleats appear frayed (see page 33).

Generic Names for Chemicals

Water Chemistry

Common name

pH Up pH Down

Alkalinity increaser

Alkalinity decreaser

Calcium increaser

Calcium decreaser

Usual chemical name

sodium hydroxide sodium bisulfate sodium bicarbonate (baking soda) sodium carbonate sodium carbonate sodium bicarbonate (baking soda)

Common brand names

pH Increaser, pH Up, pH Plus, pH Booster pH Decreaser, pH Down, pH Minus, pH

Subtractor, Dry Acid

Alkalinity Increaser, Alkaline Up sodium bisulfate calcium chloride

Alkalinity Decreaser, Alkaline Down

Calcium Increaser, Calcium Up, Calcium Plus,

Hardness Increaser

N/A To decrease calcium hardness, drain several gallons of water from the spa and refill using a mixture of 75% hard water and 25% soft water, or use a stain and scale inhibitor.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

27

28

Sanitizers

Common name

Chlorine

Bromine

Usual chemical name

sodium dichlor sodium bromide

Common brand names

Both chlorine and bromine are available under numerous brand names

Shock

Common name

MPS

Dichlor

Usual chemical name

monopersulphate sodium dichlor

Common brand names

MPS Shock, Oxy-Spa, SeaKlear

Dichlor Shock

Note: Dichlor (chlorine) is both a sanitizer and a shock. Monopersulphate (MPS), when used as a shock, can be purchased alone as non-chlorinated shock or combined with dichlor, which makes it significantly more effective than MPS alone.

Other chemical additives

Common name

Stain and scale inhibitor

Foam inhibitor

Clarifier

Do NOT use these in your spa:

Usual chemical name

These are usually proprietary chemical formulations and cannot be purchased as a single generic chemical.

Common brand names

Metal Stain Gone, Scale Inhibitor, Stain and

Scale Preventer, Stain and Scale Defense

Foam Gone, Foam Down, Defoamer

Water Brite, Spa Bright, Water Clarifier, Clear

Water, Natural Clarifier, Brite & Clear

Sodium hypoclorite (household bleach)

Trichlor

• Chemical floaters

• Bromine tablets

• Muriatic acid

• Borax or boric acid in any form, including brand names such as 20 Mule Team Borax or generic as sodium tetraborate

• Cyanuric acid, also called sun protector or chlorine protector

Common Water Chemistry Questions

Question:

Why is the use a floater not recommended to sanitize my spa water?

Answer:

We do not recommend the use of a floater for three reasons:

• The floater is unable to control the rate at which the sanitizer is dissolved into the water. When a floater is first placed in a spa, the sanitizer level can be extremely high. High sanitizer levels can chemically burn or discolor the spa’s shell or the underside of the cover. Then, after a period of time, the sanitizer level dispensed by the floater will fall to near zero. A low sanitizer level will allow viruses, bacteria or algae to grow.

• Floaters tend to stay in one area of the spa most of the time, causing this area to be exposed to extreme sanitizer levels.

• The floater may allow pieces of the highly concentrated sanitizer to fall out and settle on the floor or seat of the spa shell. These pieces of sanitizer will chemically burn (blister) the spa shell. Although your spa shell is specifically designed to resist the effects of spa chemicals, no spa surface can withstand this type of highly concentrated chemical. Remember, chemical abuse is specifically not covered under the terms of the warranty.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Question:

When I open my spa, I smell chlorine. How do I get rid of this smell?

Answer:

There are two types of chlorine in your spa. The first is the Free Available Chlorine, which is the chlorine available to sanitize your spa. This free Available Chlorine does not have an odor. The second is Chloramine, which is residue from chlorine already expended. Chloramines have a strong chlorine odor. The smell from

Chloramines can be eliminated by shocking the water. If you smell chlorine in the water, your spa is reminding you to add a shock treatment.

Question:

Why can’t I fill my spa with soft water?

Answer:

Soft water is essentially the same as regular water, except that most or all of the calcium has been replaced by sodium. Soft water may be corrosive to the heater and other components. Replacement of spa components damaged by soft water is extremely expensive.

Question:

I am trying to reduce the number of chemicals to which my family is exposed. Do I really need to use so many chemicals and in such large amounts?

Answer:

While over-exposure to any chemical can be unhealthy, many low levels of chemicals are effective and beneficial. In the case of spa water, the chemicals we recommend are needed to protect the user from waterborne pathogens (disease-causing microbes) and to prevent corrosion of spa components.

Question:

Why isn’t water chemistry damage covered by the warranty?

Answer:

The chemical levels and water quality of the water in the spa are under your direct control. With proper basic care, the spa will provide many years of hot water relaxation. If you are unsure about any chemical or its usage in the spa, contact your spa dealer.

Do’s and Don’ts

• DO add all chemicals slowly into or in front of the filter compartment with the jet pump operating for ten minutes.

• DO use special care if using baking soda to clean either the interior or exterior plastic surfaces.

• DO use only a granular form of bromine sanitizer.

• DON’T use swimming pool (muriatic) acid to lower pH.

• DON’T splash pH increaser additives on the siding.

• DON’T use compressed sanitizers.

The use of bromine sticks or tablets in floaters, which may become trapped in a lounge or cooling seat (or sink to the spa floor), have been shown to cause discoloration of or surface distress to a spa’s shell.

• DON’T use a floater type sanitization system as a low or no maintenance solution to your spa maintenance program.

Floating dispensers can become trapped in one area and cause an over-sanitization (or chemical burn) of that particular area.

If the dispenser setting is too high, the high concentration can discolor the spa shell and damage the underside of the cover.

Automatic floating dispensers have a tendency to either over-brominate or under-brominate as the rate of erosion varies greatly. Damage to the spa and cover can occur very quickly.

• DON’T use a sanitizer which is not designed for spas.

• DON’T use household bleach (liquid sodium hypochlorite).

• DON’T broadcast or sprinkle the chemicals onto the water surface. This method may cause chemically-induced spa surface blistering (chemical abuse).

29

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

30

Bather Load

“Bather Load” is the term used to describe the number of people using a spa, combined with the length of usage, and the frequency of usage. All these factors have a great effect on the spa water. The higher the bather load, the more chemicals need to be added and a longer filtration time will be needed.

Recommendations are designed for spas with average bather load (3 to 4 people, 15 minutes of usage, three times a week at 100 degrees) If your bather load exceeds these guidelines, and you experience water quality problems, increase the amount of filtration first, (go to the next higher filtration number) then if water quality is still not adequate, consult the advice of your Cal Spas dealer for additional chemical or system recommendations. Be sure to give them your bather load information.

Pure Cure™ Water Sanitizer

The Pure Cure™ water sanitizer is an optional water purification system installed at the factory. It eradicates germs in the water that are resistant to chlorine-based chemicals using high intensity UV light. Although the water sanitizer works automatically with your spa, you will still need to test for chlorine or bromine and occasionally replenish it to return the sanitizer level to the baseline. See page 25.

For spas without a circulation pump, pump 1 will run at low speed and the water sanitizer will run during filtration.

For spas with a circulation pump, the water sanitizer will run with the circulation pump.

The spa’s control system is factory-programmed with one filter cycle that will run in the evening when energy rates are often lower. The time and duration of the filter cycle can be set according to your needs. In addition, a second filter cycle can be enabled. Filtration time may need to be increased with heavy bather load.

See instructions for setting filtration cycles on page 13.

Ozonator

The ozone generator releases ozone into the spa water. You will still need to test for chlorine or bromine and occasionally replenish it to return the sanitizer level to the baseline. See page 25.

For spas without a circulation pump, pump 1 will run at low speed and the ozonator will run during filtration. You will need to increase your filtration to a minimum of six hours per day.

For spas with a circulation pump, the ozonator will run with the circulation pump.

The spa’s control system is factory-programmed with one filter cycle that will run in the evening when energy rates are often lower. The time and duration of the filter cycle can be set according to your needs. In addition, a second filter cycle can be enabled. Filtration time may need to be increased with heavy bather load.

See instructions for setting filtration cycles on page 13.

Always make sure water diverter valves are turned all the way to the left or right and never left in the center position during filtration cycles. When the diverter valve is in the center position, there is not enough suction from the pump in order to inject ozone into the spa. The ozonator will generate ozone, but it will not be injected into the water.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Troubleshooting Water Clarity Problems

Problem

Cloudy Water

Water Odor

Probable Causes

Dirty filter

Excessive oils / organic matter

Improper sanitization

Suspended particles / organic matter

Overused or old water

Excessive organics in water

Improper sanitization

Low pH

Chloramine level too high

Low pH

Bacteria or algae growth

Buildup of oils and dirt

Chlorine Odor

Musty Odor

Organic Buildup /

Scum Ring Around

Spa

Algae Growth

Eye Irritation

Skin Irritation /

Rash

Stains

Scale

High pH

Low sanitizer level

Low pH

Low sanitizer level

Unsanitary water

Free chlorine level above 5 ppm

Total alkalinity and/or pH too low

High iron or copper in source water

High calcium content in water – total alkalinity and pH too high

Possible Solutions

Clean filter and run jet pump

Shock spa with sanitizer

Add sanitizer

Adjust pH and/or alkalinity to recommended range

Drain and refill the spa

Shock spa with sanitizer

Add sanitizer

Adjust pH to recommended range

Shock spa with sanitizer

Adjust pH to recommended range

Shock spa with sanitizer – if problem is visible or persistent, drain, clean and refill the spa

Wipe off scum with clean rag – if severe, drain the spa, use a spa surface and tile cleaner to remove the scum and refill the spa

Shock spa with sanitizer and adjust pH

Shock spa with sanitizer and maintain sanitizer level

Adjust pH

Shock spa with sanitizer and maintain sanitizer level

Shock spa with sanitizer and maintain sanitizer level

Allow free chlorine level to drop below 5 ppm before spa use

Adjust total alkalinity and/or pH

Use a stain and scale inhibitor

Adjust total alkalinity and pH – if scale requires removal, drain the spa, scrub off the scale, refill the spa and balance the water

Use a stain and scale inhibitor

31

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

32

Cleaning and Maintenance

Jet Removal and Replacement

Jets can be easily removed for cleaning.

Snap-in SQR jet removal

Grasp the outer rim of the jet and turn it counterclockwise until it completely stops. You may feel it slightly loosen pop out a bit from the fixture. Pull the jet out from the jet fixture. The jet will be very snug and may require some force to remove it. DO NOT PRY OUT JETS.

To replace any jet, place it in the fitting and turn it clockwise until it snaps in and can be rotated freely about half a turn. Do not overtighten the jet.

Draining Your Portable Spa

1. Remove the cap.

Make sure the valve is in the closed position, then unscrew and remove the cap. Unscrew the cap.

2. Connect valve to a garden hose.

Attach a garden hose to the hose-bib fixture. Place the other end of the garden hose where you would like the water to drain.

3. Drain the spa.

Turn the valve on the hose-bib fixture to open the drain.

When the spa has drained completely, turn the valve on the hose-bib fixture, remove garden hose, and replace the cap.

Draining the spa using valve

Connect hose and turn valve to open position

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

Winterizing (Cold Climate Draining)

In many areas of the country, the temperature drops below 32˚F (0°C). We recommend that you always have your spa full of water and running at normal spa temperatures (80˚F to 100˚F, 26.7°C to 37.8°C). This will help reduce the risk of freezing in your spa and your spa’s equipment.

Warning: If you find the need to drain your spa, be aware of the potential of freezing in your spas equipment and plumbing. Even if the directions below are followed perfectly, there is no guarantee that your spa will not suffer freeze damage. Freeze damage is not covered by your warranty.

1. Remove the filter baskets and filters.

2. Drain your spa completely as described in the instructions above.

3. Vacuum water from the spa’s main drain and from the jets with a wet/dry vacuum.

4. Open the bleeder valves on the pumps.

5. Disconnect the unions from both sides of all pumps.

6. Blow any remaining water out of the jets and equipment area with the wet/dry vacuum.

7. When the spa has completely finished draining, close the bleeder valves and re-connect the unions on all pumps.

Replace the filters and filter baskets.

8. Cover your spa with a good spa cover and an all-weather tarp to ensure that neither rain nor snow enters the spa.

Cleaning and Replacing the Filter

Filtration is one of the most important steps you can take to ensure clean, clear water. It is far less expensive to fix water clarity problems by filtering your spa than by using excessive amounts of chemicals, excessive filtration times, or by water replacement.

See the section “Cleaning the Filter” on page 26 for more information.

Set the spa in Hold Mode before you remove the filter. Hold Mode pauses all spa operations for 60 minutes for service functions like cleaning or replacing the filter. See page 13 for instructions on using Hold Mode.

1. Remove the filter by unscrewing it and pulling it up and out.

3. Soak the filter for a minimum of 24 hours.

2. Place the dirty filter into a bucket of water deep enough to cover the filter. Add 8 oz. of liquid filter cleaner to the bucket of water.

4. Spray the filter with a water hose. Spray each pleat carefully.

5. Reinstall the filter. Do not overtighten.

Note:

It is a good idea to keep a spare filter to use in the spa while the dirty filter is being deep cleaned. This way, you can rotate the filters and both will last longer.

Spa Cover

Important! Keep the spa covered when not in use!

• Covered spas will use less electricity in maintaining your set temperature.

• Covering your spa will protect your spa’s finish from the sun’s ultraviolet rays.

• You are required to keep the spa covered to maintain warranty coverage.

• Covering your spa helps prevent children from drowning in the spa.

See the manual enclosed with your cover for instructions on mounting the locks and how to lock and unlock the cover.

In addition, while the spa cover is rigid, it is not designed to support any weight. Therefore, as a safety precaution and to preserve the life of your cover, you must not sit, stand, or lie on it, nor should you place objects of any kind on top of it.

33

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

34

Vacation Care

You can leave your spa unattended for up to two weeks if you follow these instructions.

ALWAYS lock your cover using the cover locks if you plan to be away from home and the spa is filled with water.

1. Select the Low Range temp choice used for vacation mode. (See instructions on page 12 for vacation setting.)

2. Following the water quality instructions starting on page 21, adjust the pH.

3. Shock the water (add either chlorine or bromine sanitizer).

4. When you return, check and adjust the pH and shock the water.

If you will not be using your spa for longer than 14 days and a spa maintenance service is not available, we strongly recommend you drain or winterize your spa.

Cleaning Your Spa

Spa Cover and Pillows

Due to the constant punishment your spa cover and pillows receive, you should protect them by applying a vinyl and leather cleaner as part of your monthly maintenance plan. Use a product that is specifically designed to protect spa covers and pillows from chemical and ultraviolet light damage without leaving an oily residue behind that is normally associated with common automotive vinyl protectants.

Warning:

Do not

use automotive vinyl protectants on spa covers or pillows. These products are generally oil-based and will cause severe water clarity issues that are difficult to correct.

Spa Shell

Each time you drain your spa, before you refill it you should clean your spa shell with an all-purpose cleaner and apply a coat of surface protectant.

Use a low detergent, non-abrasive cleaner specifically formulated to clean the spa without damaging its acrylic finish.

Use a non-oil based surface protectant that is specifically formulated to protect the spa’s finish from the chemicals and minerals associated with normal spa use.

Slide the clasp down to lock the door as shown at right. Make sure the door is firmly pressed into the watertight seal before you slide the lock into place.

Water damage caused by negligence or improper use is not covered under warranty.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Using the Freedom Sound System

The Freedom Sound System

entertainment option contains a Bluetooth-enabled speaker system that is available for certain

Cal Spa models. Any Bluetooth-enabled device can be used to play audio through your spa.

Before you can use the sound system, you need to pair the Bluetooth module with your device. The Bluetooth module is installed within the spa cabinet. Everything can be done with your device. The example shown below is from an iPhone device. Your device may appear differently. Before you begin, make sure Bluetooth in enabled on your device.

1. Select Bluetooth from your device’s option list.

2. Select

SWA8-1BT...

from the list of available devices to pair.

3. Allow your device to pair with the spa’s Bluetooth module.

4. When the devices have been connected, the device

SWA8-1BT...

will be highlighted.

Only one Bluetooth device can be paired with the Freedom Sound System

at any time.

Once your device is paired and connected, all sounds from your device will be played through the sound system, including system sounds and telephone.

1 2 3 4

35

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

36

Appendix

Replacement Parts

Snap-in SQR Jet Inserts

Description Used by

Velocity 5VTX Blue Jet

Symbol: 5VTX

Part #:

PLU29950-011-400

Size: 5”D x 5.5”L

Veranda

Snap-in SQR Jet Inserts

Description Used by

Velocity Roto Blue Jet

Symbol: 5R

Part #:

PLU29950-081-400

Size: 5”D x 5.5”L

Veranda

Velocity Roto LED Jet

Symbol: 5R

Part #:

PLU29950-081-100

Size: 5”D x 5.5”L

Veranda

Velocity 5VTX LED Jet

Symbol: 5VTX

Part #:

PLU29950-011-100

Size: 5”D x 5.5”L

Veranda

Velocity Directional Blue Jet

Symbol: 5D

Part #:

PLU29950-012-400

Size: 5”D x 5.5”L

Veranda

If you need jet bodies, go to www.quickspaparts.com or refer to the Cal Spa Replacement Parts Catalog, which can be downloaded from www.calspas.com/replacementparts.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Snap-in SQR Jet Inserts

Description Used by

Velocity Directional LED Jet

Symbol: 5D

Part #:

PLU29950-012-100

Size: 5”D x 5.5”L

Veranda

Please visit www.quickspaparts.com to order your replacement parts.

Snap-in SQR Jet Inserts

Description Used by

Velocity Tornado/WP Blue Jet

Symbol: 5T

Part #:

PLU29950-501-400

Size: 5”D x 5.5”L

Veranda

37

Velocity Massage-14 Blue Jet

Symbol: 5MM

Part #:

PLU29950-071-400

Size: 5”D x 5.5”L

Veranda

Velocity Tornado/WP LED Jet

Symbol: 5T

Part #:

PLU29950-501-100

Size: 5”D x 5.5”L

Veranda

Velocity Massage-14 LED Jet

Symbol: 5MM

Part #:

PLU29950-071-100

Size: 5”D x 5.5”L

Veranda

Velocity Double Roto Blue Jet

Symbol: 5DR

Part #:

PLU29950-032-400

Size: 5”D x 5.5”L

Veranda

2018 Portable Spa

LTR20181026, Rev. F

If you need jet bodies, go to www.quickspaparts.com or refer to the Cal Spa Replacement Parts Catalog, which can be downloaded from www.calspas.com/replacementparts.

www.calspas.com

38

Please visit www.quickspaparts.com to order your replacement parts.

Snap-in SQR Jet Inserts

Description Used by

Velocity Double Roto LED Jet

Symbol: 5DR

Part #:

PLU29950-032-100

Size: 5”D x 5.5”L

Veranda

Snap-in SQR Jet Inserts

Description Used by

Velocity Roto Blue Jet

Symbol: 4R

Part #:

PLU29940-122-400

Size: 4”D x 4.5”L

Veranda

Velocity Directional Blue Jet

Symbol: 4D

Part #:

PLU29940-112-400

Size: 4”D x 4.5”L

Veranda

Velocity Roto LED Jet

Symbol: 4R

Part #:

PLU29940-122-100

Size: 4”D x 4.5”L

Veranda

Velocity Directional LED Jet

Symbol: 4D

Part #:

PLU29940-112-100

Size: 4”D x 4.5”L

Veranda

Velocity Double Roto Blue Jet

Symbol: 3DR

Part #:

PLU29930-191-400

Size: 3”D x 3.25”L

Veranda

If you need jet bodies, go to www.quickspaparts.com or refer to the Cal Spa Replacement Parts Catalog, which can be downloaded from www.calspas.com/replacementparts.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Snap-in SQR Jet Inserts

Description Used by

Velocity Double Roto LED Jet

Symbol: 3DR

Part #:

PLU29930-191-100

Size: 3”D x 3.25”L

Veranda

Please visit www.quickspaparts.com to order your replacement parts.

Snap-in SQR Jet Inserts

Description Used by

Velocity Directional Blue Jet

Symbol: 3D

Part #:

PLU29930-112-400

Size: 3”D x 3.25”L

Veranda

39

Velocity Massage-7 Blue Jet

Symbol: 3M

Part #:

PLU29930-142-400

Size: 3”D x 3.25”L

Veranda

Velocity Directional LED Jet

Symbol: 3D

Part #:

PLU29930-112-100

Size: 3”D x 3.25”L

Veranda

Velocity Massage-7 LED Jet

Symbol: 3M

Part #:

PLU29930-142-100

Size: 3”D x 3.25”L

Veranda

Velocity Roto Blue Jet

Symbol: 2R

Part #:

PLU29920-022-400

Size: 2”D x 3”L

Veranda

2018 Portable Spa

LTR20181026, Rev. F

If you need jet bodies, go to www.quickspaparts.com or refer to the Cal Spa Replacement Parts Catalog, which can be downloaded from www.calspas.com/replacementparts.

www.calspas.com

40

Please visit www.quickspaparts.com to order your replacement parts.

Snap-in SQR Jet Inserts

Description Used by

Velocity Roto LED Jet

Symbol: 2R

Part #:

PLU29920-022-100

Size: 2”D x 3”L

Veranda

Snap-in SQR Jet Inserts

Description Used by

Jets

Flex Jet

PLU23120333

Velocity Directional Blue Jet

Symbol: 2D

Part #:

PLU29920-012-400

Size: 2”D x 3”L

Veranda

Duo Jet

PLU23120332

Precision Jet

PLU23120331

Velocity Directional LED Jet

Symbol: 2D

Part #:

PLU29920-012-100

Size: 2”D x 3”L

Veranda

If you need jet bodies, go to www.quickspaparts.com or refer to the Cal Spa Replacement Parts Catalog, which can be downloaded from www.calspas.com/replacementparts.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Velocity Diverter Valves

Velocity

1” Blue Diverter Valve

Symbol: D1

Part #:

PLU25056-202-400

Size: 2.5” x 5”L

Please visit www.quickspaparts.com to order your replacement parts.

Velocity Diverter Valves

Velocity Air Control LED

Symbol: A

Part #:

PLU25059-202-100

Size: 3.125” x 5”L

41

Velocity

1” LED Diverter Valve

Symbol: D1

Part #:

PLU25056-202-100

Size: 2.5” x 5”L

Velocity

2” Diverter Valve Blue

Symbol: D2

Part #:

PLU25058-202-400

Size: 4.5” x 7.75”L

Velocity Air Control Blue

Symbol: A

Part #:

PLU25059-202-400

Size: 3.125” x 5”L

Velocity

2” Diverter Valve LED

Symbol: D2

Part #:

PLU25058-202-100

Size: 4.5” x 7.75”L

If you need jet bodies, go to www.quickspaparts.com or refer to the Cal Spa Replacement Parts Catalog, which can be downloaded from www.calspas.com/replacementparts.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

42

Please visit www.quickspaparts.com to order your replacement parts.

Velocity Diverter Valves

Velocity Underwater

2” Diverter Valve Blue

Symbol: D2

Part #:

Size:

Velocity Underwater

2” Diverter Valve LED

Symbol: D2

Part #:

Size:

Velocity

1” Diverter Valve Wall Fitting LED

Part #:

PLU25030-089-200

Velocity Diverter Valves

Velocity

Wall Fitting 2” Black (#25048-004-200)

(for Diverter Valve)

Part #:

PLU21701738

Velocity

Wall Fitting 1” Black (#25030-004-200)

(for On-Off Valve)

Part #:

PLU21701739

Velocity

Air Control Wall Fitting LED

Part #:

PLU25090-089-200

Velocity

2” Diverter Valve Wall Fitting LED

Part #:

PLU25048-089-200

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Water Diverter Valves

Diverter Valve 1” Titanium

Black (CS600426T1-TT)

PLU21300453

Air Control Valve

Air Control with Titanium

Black CS660350T1-TT

PLU21300504

Drains

Drain Hi Flo Suction 1½” Black

(640-3251 VP)

PLU21400148

50 sq ft

Please visit www.quickspaparts.com to order your replacement parts.

Filters

FIL50-5D13H15FCT-3

43

50 square foot teleweir skimmer:

Teleweir Skimmers

Filter attaching cap assembly

FIL11700013

Filter skimmer inner pipe

FIL11700012

Waterfalls

Aqua Rail 12½” LED

(Blk/Clear)

FIX25262-014-000

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

44

Please visit www.quickspaparts.com to order your replacement parts.

LED Lights

1-LED light string

LIT16100330

2-LED light string

LIT16100331

4-LED light string

LIT16100332

1 to 3 ext. cord

LIT16100335

LED Lights

1 to 1 port ext. cord

LIT16100338

Interior light with logic

(7 LED)

LIT16100333

Main light housing, LED lens, fitting nut

LIT16100336

Replacement Cabinet Panels

The complete selection of replacement cabinets for all models is very extensive and too lengthy for this owner’s manual. To order replacement panels for your spa, visit www.quickspaparts.com.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Please visit www.quickspaparts.com to order your replacement parts.

Covers

All spa covers are designed with a tapered height, angling downward from the center to the sides to drive off rain and prevent water from pooling. The covers listed below are filled with either 1.5 lb or 2.0 lb foam.

Standard

4” - 2.5”

1.5 Lb. foam

Deluxe

5” - 3”

2.0 Lb. foam

45

86” x 48”

Fits spa models: V418B, V420B, V422B

Gray

Standard

OPT86480B42G

Slate

Standard

OPT86480B42S

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

46

Basic Troubleshooting

The troubleshooting guidance provided here is intended to cover the most common problems a spa owner may encounter.

For more in-depth troubleshooting, go to www.calspas.com/troubleshooting.

Possible Solutions Symptom

Problems starting up

Pump won't prime

Breaker keeps shutting off

See priming instructions on page 9.

Reset the GFCI breaker. If this continues, contact your dealer or a qualified spa technician.

Power and system problems

System won’t start up or breaker keeps shutting off

Control panel doesn’t respond

Spa does not turn off

Power may be shut off. Turn on GFCI circuit breaker. If this continues, contact your dealer or a qualified spa technician.

Turn on or reset the GFCI circuit breaker. If this does not solve the problem, contact your dealer or a qualified spa technician.

If you hear the pump running but the control panel doesn’t respond, contact your dealer

Spa may be trying to heat up. Check if spa is in Ready or Rest mode (see page 13)

In cold climates, if spa is not equipped with full foam or any kind of insulation, it will try to maintain the set temperature. Set the spa to low temperature range and set the temperature to 80°F.

Spa may be in filter cycle. If it is, this is normal and no adjustment is necessary.

There may be a problem. See Error Screens on page 14.

Message on the control panel

Heat problems

Spa water does not get hot Spa may be in low temperature range. Set the spa to high temperature range.

The filter may be dirty or may need to be replaced. Clean or replace the filter.

The water level may be too low. Fill the spa with water level at 4 to 6 inches from the top.

The temperature is not turned up high enough. Raise temperature on topside control.

Cover the spa. The cover will keep heat in the spa and help keep heat from escaping. Make sure cover is on at all times when spa is not in use.

The heater element may be old, deteriorated, coated with scale, or defective.

Contact your dealer for more assistance.

The gate valves may be partially or completely closed. NEVER OPERATE YOUR

SPA WITH THE GATE VALVES CLOSED!

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Symptom

Spa overheats - temperature greater than 110°F / 43°C

Possible Solutions

Overheating can occur during summer months and may not necessarily indicate a malfunction. When it occurs, a message code may also appear on the control panel.

Temperature may be set too high. Turn the set temperature down to a lower temperature.

Filtration time may be too long. Turn the filtration cycles down during the warm months.

The spa may not be properly ventilated. Make sure the front of the spa is not blocked to allow air flow.

High speed pumps may have been running too long. Limit pump running time to no more than 15 to 30 minutes.

Water pressure problems

Low water pressure

No water pressure (no water stream from any jets)

Jets surge on and off

Pump problems

Pump runs constantly – will not shut off

Noisy pump

Jet valves may be partially or fully closed. Open the jet valves.

Filter cartridge may be dirty. Clean or replace the filter.

Pump may have airlock. Remove airlock by priming spa (page 9)

The suction fittings may be blocked. Remove any debris that may be blocking them.

The filter skimmer may be blocked. Remove the blockage.

Gate valves may be closed. Open gate valves. Note: Never operate your spa with the gate valves closed!

Spa may be running in filtration mode. Press JETS or JETS 1 button to turn on high speed pump.

Power may be switched off. Turn the power back on.

The pump may be defective. After you have tried all other troubleshooting, contact your dealer for assistance.

Water level may be too low. Add water to normal level.

There may be a problem with circuit board. Contact your dealer.

The water level may be too low. Fill the spa with water level at 4 to 6 inches from the top.

Filter cartridge may be dirty. Clean or replace the filter.

Pump may have airlock. Remove airlock by priming spa (page 9)

The suction fittings may be blocked. Remove any debris that may be blocking the suction fittings.

Gate valves may be closed. Open gate valves. Note: Never operate your spa with the gate valves closed!

Air may be leaking into the suction line. Contact your dealer for assistance.

Debris may be inside the pump. Contact your dealer for assistance.

Noise may be a sign of damage. Contact your dealer for service.

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

47

48

Symptom

Pump turns off during operation

Pump has a burning smell while running

Pump does not run

Possible Solutions

Automatic timer may have completed its cycle. Press JETS or JETS 1 button to start the cycle again.

Pump may have overheated due to the vents on the equipment door being blocked. Make sure the front of the spa is not blocked to allow air flow.

The pump motor may be defective. Contact your dealer for assistance.

A burning smell may be a sign of damage. Contact your dealer for service.

Pump may have over heated. Let it cool for an hour and try operating the spa for a shorter time.

Power to the spa may be shut off. Turn on or reset the GFCI circuit breaker.

If this does not solve the problem, contact your dealer or a qualified spa technician.

“Thermal Creep”

Cal Spas are designed with energy-efficient components and systems that are meant to sustain heat generated by the equipment, which is then cycled back into the spa water. In hot weather or in situations where the spa is set to extended run times, Thermal Creep may occur. Thermal Creep is a condition where the measured water temperature can be higher than the set temperature. To manage Thermal Creep you may:

Vent your cover.

This means placing a folded cloth about ¾” (2cm) thick under all four corners of the cover before you lock the cover down.

Open your cover.

Opening the cover at night will also quickly cool the water down if desired.

Open all air controls.

Set your filtration cycles to run during the cooler times of the day or night.

Reduce the length of your filter cycles.

Visit your local dealer for additional guidance.

Since Thermal Creep only occurs in well-insulated hot tubs, it is not indicative of something that is wrong with your spa or its equipment.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

Limited Warranty

This Limited Warranty is extended to the original purchaser of a Cal Spa brand portable spa manufactured after

January 1, 2018 and installed for residential use in the United States of America and Canada. This warranty begins on the date of delivery of the spa, but in no event later than one year from the date of manufacture.

This warranty applies only to this spa line:

Veranda

Shell Structural

Warranted against water loss due to defects in the spa shell.

Shell Finish

Warranted against blistering, cracking, or delaminating of the interior surface of the spa shell.

Equipment and Controls

Electrical equipment components – specifically limited to the pumps, standard titanium heater, and control system – are warranted against malfunctions due to defects in workmanship or materials.

Plumbing

Warranted against leaks due to defects in workmanship or materials.

Cabinet - Synthetic, Fiberglass, or Wicker

Warranted against defects in workmanship or materials. Normal wear and weathering of the finish will occur naturally over time and are not defects.

5 years

2 years

2 years

2 years

1 year

Warranties for Other Components

The fuses, headrests, cabinet finish, and filters are warranted to be free of defects in workmanship and material at the time of delivery. The factory installed water purification system is warranted against malfunction due to defects in workmanship or material for one year from the original date of delivery, except for the UV bulb and quartz tube, which are warranted for

90 days from the original date of the spa delivery. All stereo-related components (receiver, speakers, sub-woofer, stereo media locker, power supply, wireless remote control etc.) are warranted against malfunction due to defects in workmanship or material for one year from the original date of delivery. All other factory-installed components not mentioned specifically, including, but not limited to the wood frame, jets, diverter valves, LED lighting systems, filter lids, and mechanical components, are warranted against malfunction due to defects in workmanship and material for two years from the original date of delivery. The spa cover delivered with the spa is warranted for one year for Escape and Special Edition spas, 90 days for Zone, Connect, and New Age spas.

Genuine Cal Spas Parts & Accessories

This Limited Warranty is void if Cal Spas (the “Manufacturer”) or its designated representative determines that the spa has been subjected to damage or failure due to installation of aftermarket parts that are not genuine Cal Spas branded parts and accessories. This disclaimer includes, but is not limited to filters, UV bulbs, ozone systems, salt systems, repair parts and other accessories. Genuine Cal Spas brand parts and accessories are built to our highest standards of quality, durability and performance, and they are designed to work with your spa to ensure optimal performance and function.

49

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

50

Performance

This warranty begins on the date of delivery of the spa, but in no event later than one year from the date of manufacture.

To obtain service in the event of a defect covered by this Limited Warranty, notify your Cal Spa dealer or Cal Spas as soon as possible and use all reasonable means to protect the spa from further damage. Upon proof of purchase, a designated service representative will correct the defect subject to the terms and conditions contained in this Limited Warranty. There will be no charge for parts or labor to repair the defect, although providing access to affect the repair is your responsibility as the spa owner. Freight charges for replacement parts is the responsibility of the spa owner. You may be assessed reasonable repairman travel mileage charges.

In the event that the spa is removed to a repair facility for repair and reinstalled, the cost of removal and reinstallation will be your responsibility as the spa owner. If the Manufacturer determines that repair of the covered defect is not feasible, it reserves the right to provide a replacement spa instead, equal in value to the purchase price of the original spa. In such an event, reasonable costs for removal of the original spa, shipping costs from the factory for the replacement spa and delivery and installation of the replacement will be your responsibility as the spa owner. The replacement spa will carry the balance of the original spa’s warranty. Spa covers are not included.

This warranty ends either by specified time frame, owner-transfer, relocation, or installation of any component other than by manufacturer.

Warranty Limitations

This Limited Warranty is void if Cal Spas or its designated representative determines that the spa has been subjected to alteration, neglect, misuse or abuse, or freight damage caused by the common carrier; any repairs have been attempted by anyone other than a designated representative; the failure is caused by accident, acts of God or other causes beyond the control of the Manufacturer; neglect, misuse and abuse include any installation, operation or maintenance of the spa other than in accordance with the instructions contained in the owner’s manual provided with the spa, including but not limited to the failure to maintain proper water chemistry and chemical balance and the use of abrasive or improper cleaners or non-genuine parts and accessories. This Limited Warranty does not provide coverage for any item attached to or installed on the spa after the date of manufacture or for gaining access to any component for repair or replacement. Spa units in commercial use are excluded from any coverage whatsoever. The spa owner accepts liability for repair work performed by anyone other than the Manufacturer or a designated Cal Spa representative.

Limitations

The Manufacturer disclaims all warranties, expressed or implied, in fact or in law, to the extent allowed by your State’s

Law, including the warranty of merchantability and fitness for use, except as stated specifically herein. All warranty service must be performed by the Manufacturer or its designated representative using authorized Cal Spa parts. No agent, dealer, distributor, service company or other party is authorized to change, modify or extend the terms of this limited warranty in any manner whatsoever. The Manufacturer will not be responsible for any statements or representations made in any form that go beyond, are broader than, or are inconsistent with any authorized literature or specifications furnished by Cal Spas.

Disclaimers

The Manufacturer and its representatives shall not be liable for any injury, loss, cost or other damage, whether incidental or consequential, arising out of any defect covered by this limited warranty, including without limitation, loss of use of the spa and cost for removal of defective product even if the Manufacturer was advised of the possibility of damage. The liability of the Manufacturer under this limited warranty, if any, shall not exceed the original amount paid for the defective product.

Coverage under this limited warranty shall commence as of the original date of delivery and the duration of such coverage shall not extend for any reason whatsoever beyond the stated time periods. These disclaimers shall be equally applicable to any service provided by the Manufacturer and its designated representatives.

Legal Rights

This Limited Warranty gives you specific legal rights. You may also have other rights that vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you.

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

51

52

www.calspas.com

2018 Portable Spa

LTR20181026, Rev. F

2018 Portable Spa

LTR20181026, Rev. F

www.calspas.com

53

54

Warranty Registration

Registering your new Cal Spas product is quick and easy. It is important that you register your Cal Spas product as soon as possible. By taking just a few quick minutes to register, you can enjoy product alerts, more efficient support, and quicker service.

Go to www.calspas.com/warranty . Fill in your information and click “Send Warranty Info”

Locating the product serial number:

The serial number of your spa is located on a metal plate attached to the inside of the door for the equipment area. You will need this number to properly register your spa and activate coverage. Write this information in the space provided below.

Spa Model: ___________________________________________________________________________________

Spa Serial Number: ____________________________________________________________________________

Date Purchased: _______________________________________________________________________________

Date Installed: ________________________________________________________________________________

Dealer’s Phone Number: ________________________________________________________________________

Dealer’s Address: ______________________________________________________________________________

Please visit www.quickspaparts.com to order your replacement parts.

www.calspas.com

LTR20181026, Rev. F

5/16/18

2018 Portable Spa

LTR20181026, Rev. F

advertisement

Related manuals

Download PDF

advertisement