Davey DHP130 is an efficient and environmentally friendly heat pump that uses R32 gas and step-less DC inverter technology to extract heat from the surrounding air and transfer it to your pool water. This method generates substantial energy savings and provides a comfortable swimming experience. With its user-friendly interface and various operating modes, you can easily adjust the temperature and customize the settings to suit your needs.
advertisement
Pool Heat Pump
Installation and Operating
Instructions
Please pass on these instructions to the operator of this equipment.
Table of Contents:
1. FOREWARD .................................................................................................................................................
3
2. SAFETY PRECAUTIONS .............................................................................................................................
3
2.1 Warning ...................................................................................................................................................3
2.2 Attention ..................................................................................................................................................3
2.3 Safety ......................................................................................................................................................4
3. ABOUT YOUR HEAT PUMP .........................................................................................................................
4
3.1 Transportation .........................................................................................................................................4
3.2 Accessories .............................................................................................................................................4
3.3 Features ..................................................................................................................................................5
3.4 Operating range ......................................................................................................................................5
3.5 Introduction of different modes ................................................................................................................5
3.6 Technical parameter ................................................................................................................................5
3.7 Dimensions ..............................................................................................................................................6
4. INSTALLATION GUIDANCE ........................................................................................................................
7
4.1 Installation reminder ................................................................................................................................7
4.2 Wiring ......................................................................................................................................................8
4.3 Electric wiring diagram ............................................................................................................................8
4.4 References for protecting devices and cable specification .....................................................................8
5. OPERATION GUIDANCE .............................................................................................................................
9
5.1 Key function .............................................................................................................................................9
5.2 Operation instruction ...............................................................................................................................9
6. TESTING .....................................................................................................................................................
10
6.1 Inspect heat pump before use ...............................................................................................................10
6.2 Leakage detection method ....................................................................................................................10
6.3 Trial ........................................................................................................................................................10
7. MAINTENANCE ..........................................................................................................................................
11
8. TROUBLE SHOOTING FOR COMMON FAULTS ......................................................................................
12
8.1 Repairing Guidance ...............................................................................................................................12
8.2 Failure solution and code ......................................................................................................................12
9. WATER PUMP CONTROL CONNECTION .................................................................................................
14
10. WI-FI OPERATION ....................................................................................................................................
17
2
1. FOREWARD
The Davey heat pump uses eco-friendly R32 gas and step-less DC inverter technology which allows heat to be extracted from the surrounding air more efficiently. This heat is transferred to the pool water by a twisted titanium heat exchanger. This method generates substantial energy savings compared to: a conventional electric resistance heater, and natural, or propane gas pool heaters.
2. SAFETY PRECAUTIONS
We have provided important safety messages in this manual and on your heat pump.
Please always read and obey all safety messages.
Environmentally friendly R32 Refrigerant is used for this heat pump.
2.1 Warning
R32 Gas
The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury or injury to a third party. These signs are rare, butare extremely important. a. Keep the heat pump away from fire source.
b. It must be placed in well ventilated area, indoor or closed area is not suitable.
c. Repair and disposal must be carried out by trained service personnel
2.2 Attention
a. Please read the following instructions before installation, use and maintenance.
b. Installation must be done by professional staff only in accordance with this manual and any local regulations.
c. Leakage test must be performed after installation.
d. Please don’t stack substances, which will block air flow near inlet or outlet area, otherwise the efficiency of the heat pump will be reduced or even stopped.
e. Set proper temperature in order to get a comfortable water temperature to avoid overheating or overcooling.
f. In order to optimize the heating effect, please install heat preservation insulation on pipes between swimming pool and the heat pump, and please use a recommended cover on the swimming pool.
g. Connecting pipes of the swimming pool and the heat pump should be ≤10m.
h. Except for the methods recommended by the manufacturer, do not use any methods to accelerate the defrosting process or clean the frosted parts.
i. If a repair is required, please contact the nearest after-sales service centre. The repair process must be strictly in accordance with manual. All repair practice by non-professional is prohibited.
j. Don’t use or stock combustible gas or liquid such as thinners, paint and fuel to avoid fire.
3
2.3 Safety
a. Please keep the main power supply switch far away from children.
b. When a power outage happens during operation, the heat pump will start when the power is restored..
c. Please switch off the main power supply in lightening and storm weather to prevent from damage caused by lightning.
d. Safety inspection must be carried before the maintenance or repair of heat pumps with R32 gas in order to minimize the risk.
e. Installation and any repairing should be conducted in an area with adequate ventilation and with no nearby ignition sources.
f. If R32 gas leaks during the installation process, all operations must be stopped immediately and call the service centre.
3. ABOUT YOUR HEAT PUMP
3.1 Transportation
a. Always keep upright b. Do not lift the water union
(Otherwisethe titanium heat exchangermay be damaged)
3.2 Accessories
Water Union
Drainage Kit
Connection of the condensate drainage kit:
4
3.3 Features
a. DC Twin-rotary inverter compressor of Mitsubishi b. DC Brushless fan motor c. EEV Technology d. Reverse cycle defrosting with 4-way valve e. High-efficiency twisted titanium heat exchanger f. Sensitive and accurate temp control and water temp display g. High pressure and low pressure protection h. Full protection on electrical systemea
3.4 Operating Range
To get the best results from your Davey heat pump please set swimming pool water temperature efficiently and economically.
The heat pump can operate in temperatures between -10°C – 43°C, and its ideal operation range is between air 15°C – 25°C.
In accordance with AS/NZS 60335.2.41 we are obligated to inform you that this Davey heat pump is not to be used by children, or infirm persons and must not be used as a toy by children. Please ensure young children are supervised to ensure that they do not play with the heat pump.
3.5 Introduction of different modes
The heat pump has two modes: Boost and Silence.
They have different strengths under different conditions.
MODE MODES
Boost mode
Silence mode
STRENGTH
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fast heating
Heating capacity: 20% to 80% capacity
Sound level: 3dB (A) lower than Boost mode
3.6 Technical parameter
MODE DHP90
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity(kW) 9.0
COP at 50% fan speed 10.5
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity(kW)
COP at 50% fan speed
TECHNICAL SPECIFICATION
Advised pool volume (m 3 ) *
Operating air temperature (°C)
6.6
6.5
20 – 45
-10°C – 43°C
Power supply
Rated input power (kW)
Rated input current (A)
Sound level at 10m dB(A)
Advised water flow (m³/h)
Water connection (mm)
0.19 – 1.38
0.83 – 5.98
16.8 – 26.1
2 – 4
230V 1Ph
40
DHP130
13.0
10.5
9.0
6.4
35 – 65
0.26 – 1.8
1.13 – 7.83
20.1 – 28.7
4 – 6
Remarks:
This heat pump is able to perform normal within air temp -10°C – +43°C, efficiency will not be guaranteed out of this range. Please take into consideration that the pool heat pump performance and parameters are different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further notice.
5
For details please refer to nameplate.
3.7 Dimensions
C E
A
D B
Model
DHP90
DHP130
A
410
410
B
645
645
DIMENSIONS (mm)
C
404
404
D
430
430
E
890
890
F
250
280
G
75
75
H
658
658
* Above data is subject to modification without notice.
NOTE: The picture above is the specification diagram of the pool heat pump, for technician’s installation and layout reference only. The product is subject to adjustment periodically for improvement without further notice.
6
4. INSTALLATION GUIDANCE
4.1 Installation reminder
The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual.
To get the best results from your Davey heat pump, its location is critical. The Davey heat pump takes hot air from its surroundings and transfers this heat through its heat exchanger, to the pool water.
Your Davey heat pump should be installed in a well ventilated area.
WARNING: Improper installation, adjustment, service, maintenance or use can cause fire, electrical shock or other conditions which may cause injury or property damage. Consult a qualified technician or service agency for information or assistance. All service calls under warranty should be authorized by Davey Water Products.
1) The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid and fastened; the bracket must be strong enough and antirust treated;
2) Please ensure 50cm of clearance around each side of the Davey heat pump or the efficiency of the heat pump will be reduced;
3) Although a bypass system is not necessary for your Davey heat pump to operate properly, we strongly recommend the installation of a bypass system to make the maintenance and winterising of the Davey heat pump easier.;
4) When the heat pump is running, there will be condensation water discharged from the bottom. Please use the drainage kit supplied.;
5) Your Davey heat pump must be connected with hard pipes.
4.2 Wiring
7
WARNING: The electrical connection should be done by a qualified electrician according to national, state and local city codes or standards.
The unit should be connected to a compatible RCD (Residual Current Device).
4.3 Electric wiring diagram
a. For power supply: 230V 50Hz
Distribution Box Swimming Pool Heater
Pump Wiring Board
Power Cord
Power Supply
230V 50Hz
Breaker
Fuse
Earthing
NOTE:
Your Davey heat pump must be hard wired and correctly earthed.
4.4 References for protecting devices and cable specification
Breaker
MODEL
Rated Current (A)
Rated Residual Action Current (mA)
Fuse (A)
Power Cord (mm 2 )
Signal Cable (mm 2 )
DHP90
10.5
30
10.5
3 x 2.5
3 x 0.5
DHP130
14.5
30
14.5
3 x 2.5
3 x 0.5
* Above data is subject to modification without notice.
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is >10m, wire diameter must be increased. The signal cable can be extended to 50mm maximum.
8
5. OPERATION GUIDANCE
5.1 Key Function
SYMBOL HEATING ONLY MODELS
1. Power On/Off
2. Wi-Fi setting
Lock/Unlock screen
1. Boost
2. Silence
Temperature Setting
From 18 – 40°C
ATTENTION: i. The controller has power-down memory function.
ii. The buttons will turn dark when it’s locked.
5.2 Operation Instruction
a. Screen Lock
1) Press for 3 seconds to lock or unlock the screen.
2) Automatic Lock Period: 30 seconds if no operation.
b. Power On
Press for 3 seconds to unlock screen. Press to power on machine.
c. Temperature Setting
Press to display and set temperature.
d. Mode Selection
1) Silence/Boost mode selection.
Press to switch among boost mode , silence mode .
Default mode: boost
Please choose boost mode for initial heating
9
e. Wi-Fi
When the screen is on, press
for 3 seconds, after flashing, enter Wi-Fi connection. Connect Wi-Fi successfully lights on.
f. Defrosting
1) Automatic defrosting: When machine is auto defrosting, will flash, and return to previous working mode when it finishes.
2) Manual Defrosting: To enter forced defrosting mode, the compressor must be on for more than 10 minutes. In heating mode, hold and on touch controller simultaneously for 5 seconds to start forced defrosting, is flashing and defrost starts, stop flashing and defrosting stops.
(Remarks: the interval between manual defrosting should be more than 30 minutes).
6. TESTING
6.1 Inspect heat pump before use
a. Ensure the ventilation is adequate and there are no obstructions.
b. Ensure your Davey heat pump is not close to any corrosive substances.
c. Verify that the electrical wiring has been completed as per instructions.
6.2 Leakage detection notice and method
a. Keep away from any sources of ignition. A halide torch
(or any other detector using a naked flame) shall not be used.
R32 Gas b. Leakage detection fluids can be applied with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe.
c. If a gas leak occurs, cease operation and contact a Davey service centre.
6.3 Trial
a. Your water circulation pump must be running before your Davey heat pump starts and needs to continue running until after your heat pump stops. This will avoid damage to your heat pump.
b. Please check for any water leaks before starting your Davey heat pump.
c. For protection, your Davey heat pump is equipped with a time lag starting function, the fan will run 1 minute earlier than the compressor on start-up, and it will stop running 1 minute later than the compressor when your heat pump is stopped.
d. If you notice any abnormal noises from your heat pump, please turn it off and contact Davey.
10
7. MAINTENANCE
Disconnect the power to the heat pump before any inspection, cleaning or service.
1. Winterising your heat pump:
Winterising is required in conditions where any water inside the heater can drop below 0°C. In this situation, if not carried out, severe damage is likely to occur to the Davey heat pump.
a. Turn off the circuit breaker, or isolation switch; b. Drain the Davey heat pump. Loosen all water connections; c. Rinse the interior of the heat exchanger cylinder with a stream of tap water for about 15 minutes to remove any chlorine residue that could cause damage to the heat exchanger. d. Tilt the unit towards the back to remove all water from the unit.
e. Block water inlet and outlet with a cloth or plastic to prevent mice, or other animals from entering the unit.
WARNING: All water connections to the pool should be disconnected for winter to allow complete drainage of the Davey heat pump. The winterising must be done before air temperatures reach freezing point.
WARNING: The Davey heat pump should never be tilted more than 30-35º, even during transportation. Should this occur, allow the Davey heat pump to sit for
4 hours before turning on.
2. Please clean this machine with household detergents or clean water, NEVER use gasoline, thinners or any similar fuel.
3. Always disconnect the Davey heat pump before:
Opening the access door;
Cleaning the cabinet, or evaporator.
To avoid the risk of injuries, or damage to the unit, never:
Sit on the Davey heat pump, or place a heavy object on it;
Put objects in, or on the protective grid.
The Davey heat pump requires professional maintenance and repair. Any “do-it-yourself” repairs on a unit within warranty period, may void the remainder of the manufacturer’s warranty. Maintenance, or adjustments other than those recommended in this owner’s manual should not be attempted. Contact
Davey for any questions, or problem you may have with your unit.
11
8. TROUBLE SHOOTING FOR COMMON FAULTS
8.1 Repairing Guidance
WARNING: Improper installation, adjustment, service, maintenance or use can cause fire, electrical shock or other conditions which may cause injury or property damage.
Consult a qualified technician or service agency for information or assistance. All service calls under warranty should be authorized by Davey Water Products.
c. Any person who is involved with working on a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with national, state and local city codes and standards.
d. Do not attempt to work on the equipment by yourself. Improper operation may cause danger.
e. Strictly comply with the manufacturer’s requirements when charging R32 gas and equipment maintenance.
8.2 Failure solution and code
Failure Reason
No power
Power switch is off
Solution
Wait until the power recovers
Switch on the power
Heat pump doesn’t run
Fuse burned
The breaker is off
Evaporator blocked
Check and change the fuse
Check and turn on the breaker
Remove the obstacles
Fan running but with insufficient heating
Air outlet blocked
3 minutes start delay
Set temp. too low
Remove the obstacles
Wait patiently
Set proper heating temp.
Display normal, but no heating
3 minutes start delay Wait patiently
If above solutions don’t work, please contact your installer or Davey service agent with detailed information and your model number. Don’t try to repair it yourself.
NOTE: If the following conditions happen, please stop the machine immediately, and cut off the power supply immediately, then contact your dealer or Davey:
1. Inaccurate switch action.
2. The fuse is frequently broken or leakage circuit breaker jumped.
12
10
11
12
13
6
7
8
9
14
15
16
17
18
2
3
4
5
4
5
No.
1
23
24
25
26
19
20
21
22
27
28
P3
P4
P5
P6
EA
P0
P1
P2
P7
P8
P9
PA
F1
Eb
Ed
Display
E1
E2
E4
E7
E8
F6
F7
F8
F9
F2
F3
F4
F5
Fb
FA
Protection and Failure Codes
No.
1
2
3
Display
E3
E5
E6
Protection Code Description
No water protection
Power supply exceeds operation range
Excessive temp difference between inlet and outlet water
(Insufficient water flow protection)
Ambient temperature too high or too low protection
Anti-freezing reminder
Failure Code Description
High pressure protection
Low pressure protection
3 phase sequence protection (three phase only)
Water outlet temp too high or too low protection
High exhaust temp protection
Evaporator overheat protection (only at cooling mode)
Controller communication failure
Water inlet temp sensor failure
Water outlet temp sensor failure
Gas exhaust temp sensor failure
Evaporator coil pipe temp sensor failure
Gas return temp sensor failure
Cooling coil pipe temp sensor failure
Ambient temp sensor failure
Cooling plate sensor failure
Current sensor failure
Restart memory failure
Compressor drive module failure
PFC module failure
Compressor start failure
Compressor running failure
Inverter board over current protection
Inverter board overheat protection
Current protection
Cooling plate overheat protection
Fan motor failure
Power filter plate No-power protection
PFC module over current protection
13
connection
Water pump: 230V voltage, ≤ 500W capacity
Breaker/fuse
(Customer prepare)
Earthing
Powercord
Power Supply
230V~/50Hz
Customer remote control connector switch
Water Pump
Breaker/fuse
(Customer prepare)
Power Supply
230V~/50Hz
Earthing
Option 1 - for use with the main pool filtration pump - when the heat pump power is on, the water pump will run continuously even when the heat pump reaches its set temperature and goes into standby mode.
Option 2 - for use only when there is a dedicated pump for the pool heating - when the pool water reaches the set temperature, the heat pump will stop, the water pump will turn off 1 minute later.
Inverter heat pump solution 16
14
Water pump: 230V voltage, > 500W capacity
Breaker/fuse
(Customer prepare)
Earthing
Powercord
Power Supply
230V~/50Hz
Power Supply
230V~/50Hz
Earthing
Breaker/fuse
(Customer prepare)
Contactor
Customer remote control switch connector
Water Pump
Inverter heat pump solution
15
17
J. Wi-Fi operation
Inverter heat pump solution
16
20
Inverter heat pump solution
17
21
Inverter heat pump solution 18
22
Inverter heat pump solution
19
23
Inverter heat pump solution 20
24
Inverter heat pump solution
21
25
NOTES
22
23
Davey Warranty
Davey Water Products Pty Ltd (Davey) warrants all products sold will be (under normal use and service) free of defects in material and workmanship for a minimum period of one (1) year from the date of original purchase by the customer as marked on the invoice, for specific warranty periods for all Davey products visit daveywater.com.
This warranty does not cover normal wear and tear or apply to a product that has:
• been subject to misuse, neglect, negligence, damage or accident
• been used, operated or maintained other than in accordance with Davey’s instructions
• not been installed in accordance with the Installation Instructions or by suitably qualified personnel
• been modified or altered from original specifications or in any way not approved by Davey
• had repairs attempted or made by other than Davey or its authorised dealers
• been subject to abnormal conditions such as incorrect voltage supply, lightning or high voltage spikes, or damages from electrolytic action, cavitation, sand, corrosive, saline or abrasive liquids,
The Davey warranty does not cover replacement of any product consumables or defects in products and components that have been supplied to Davey by third parties (however Davey will provide reasonable assistance to obtain the benefit of any third-party warranty).
To make a warranty claim:
• If the product is suspected of being defective, stop using it and contact the original place of purchase. Alternatively, phone
Davey Customer Service or send a letter to Davey as per the contact details below
• Provide evidence or proof of date of original purchase
• If requested, return the product and/or provide further information with respect to the claim. Returning the product to the place of purchase is at your cost and is your responsibility.
• The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if:
- a relevant defect is found
- the warranty claim is made during the relevant warranty period; and
- none of the excluded conditions listed above apply
• The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organise collection of the product at their expense or authorise its disposal.
If the claim is found to be valid Davey will, at its option, repair or replace the product free of charge.
The Davey warranty is in addition to rights provided by local consumer law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
For any internet connected products the consumer is responsible for ensuring a stable internet connection. In the event of a network failure the consumer will need to address the concern with the service provider. Use of an App is not a substitute for the User’s own vigilance in ensuring the product is working to expectation. Use of a Smart Product App is at the User’s own risk. To the fullest extent permitted by law Davey disclaims any warranties regarding the accuracy, completeness or reliability of App data. Davey is not responsible for any direct or indirect loss, damage or costs to the User arising from its reliance on internet connectivity. The User indemnifies Davey against any claims or legal actions from them or others relying on internet connectivity or App data may bring in this regard.
Products presented for repair may be replaced by refurbished products of the same type rather than being repaired.
Refurbished parts may be used to repair the products. The repair of your products may result in the loss of any user-generated data. Please ensure that you have made a copy of any data saved on your products.
To the fullest extent permitted by law or statute, Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under local laws and does not affect any rights or remedies that may be available to you under local laws.
For a complete list of Davey Dealers visit our website (daveywater.com) or call:
NEW ZEALAND
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph:
Fax:
0800 654 333
0800 654 334
Email: [email protected]
NORTH AMERICA
Ph: 1-877-885-0585
Email: [email protected]
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517 daveywater.com
AUSTRALIA
ce
6 Lakeview Drive,
Scoresby, Australia 3179
Ph:
Fax:
1300 232 839
1300 369 119
Email: [email protected]
EUROPE
ZAC des Gaulnes
355 Avenue Henri Schneider
69330 Meyzieu, France
Ph:
Fax:
+33 (0) 4 72 13 95 07
+33 (0) 4 72 33 64 57
Email: [email protected]
MIDDLE EAST
Ph:
Fax:
® Davey is a trademark of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2020.
* Installation and operating instructions are included with the product when purchased new.
They may also be found on our website.
+971 50 6368764
+971 6 5730472
Email: [email protected]
P/N DWP1982
advertisement
Key Features
- Uses eco-friendly R32 gas for energy efficiency and environmental protection
- Step-less DC inverter technology for precise temperature control and energy savings
- Twisted titanium heat exchanger for efficient heat transfer and durability
- Multiple operating modes (heat, cool, auto, sleep) for customized comfort
- User-friendly interface with LED display for easy operation and monitoring
- Built-in Wi-Fi for remote control and monitoring via a smartphone app
- Suitable for both indoor and outdoor pools, providing year-round swimming enjoyment
Related manuals
Frequently Answers and Questions
What is the operating range of the Davey DHP130 heat pump?
What is the recommended pool size for the Davey DHP130 heat pump?
Can the Davey DHP130 heat pump be used in both indoor and outdoor pools?
advertisement
Table of contents
- 3 2.1 Warning
- 3 2.2 Attention
- 4 2.3 Safety
- 4 3.1 Transportation
- 4 3.2 Accessories
- 5 3.3 Features
- 5 3.4 Operating range
- 5 3.5 Introduction of different modes
- 5 3.6 Technical parameter
- 6 3.7 Dimensions
- 7 4.1 Installation reminder
- 8 4.2 Wiring
- 8 4.3 Electric wiring diagram
- 8 4.4 References for protecting devices and cable specification
- 9 5.1 Key function
- 9 5.2 Operation instruction
- 10 6.1 Inspect heat pump before use
- 10 6.2 Leakage detection method
- 10 6.3 Trial
- 12 8.1 Repairing Guidance
- 12 8.2 Failure solution and code