protech QM1527 Manual
Protech QM1527 is a versatile digital multimeter with NCV detection, voltage, current, and resistance measurement capabilities. It features a large backlit LCD display, data hold and auto-ranging functions, and can perform diode, continuity, and live wire recognition tests. With its compact size and rugged construction, it's ideal for both professional and DIY electrical work.
Werbung
Werbung
Non-Contact
Voltage Detection
Digital Multimeter
HOBBYIST
2 YEAR
WARRANTY
DATA
HOLD
CAT III
500V
AUTO
BACKLIGHT
THIS PAGE INTENTIONALLY LEFT BLANK
2
QM1527
Non-Contact
Voltage Detection
Digital Multimeter
Thank you for purchasing this Non-Contact Voltage Detection Digital
Multimeter. This multimeter includes an internal buzzer and LED warning light to indicate when power is earthed, voltage is detected, the circuit is leaking or resistance is lower than around 70Ω. Manual range selection allows you to work with preferred ranges. Equipped with a data hold option which allows you to lock your readings on-screen for data analysis, as well as an LCD backlight which activates automatically in low light conditions.
Please familiarise yourself with the functions of the multimeter before use. We recommend retaining this manual for ease of reference.
• Improper use of this meter can cause damage, shock, injury or death.
• Always remove the test leads before replacing the battery or fuses.
• Before using the meter, please inspect the condition of the test leads and the meter itself for any damage. If damage is present, please discontinue use.
• Do not measure voltage if the voltage on the terminals exceeds 1000V above earth ground.
• Use great care if voltages are greater than 30VAC RMS. Anything above this is considered a shock hazard.
• Always discharge capacitors and disconnect power before performing diode, resistance or continuity tests.
• Do not exceed the maximum limits of the input values shown in the specification tables on pages 9 & 10 of this manual.
• Remove the batteries from the meter if it will be unused for an extended period of time.
3
FUNCTIONS
Max. Display
Basic Accuracy
DC Voltage Range
AC Voltage Range
DC Current Range
Resistance
Square Wave Output
Diode Test
Continuity Check
NCV (Non-Contact Voltage)
Detection
LINE (Live Wire Recognition)
Test
LCD Backlight
Data Hold
Manual Range
Yes
Yes
Yes
Yes
2000 Count
0.5%
200mV - 500V
200V - 500V
200µA - 10A
200Ω - 2MΩ
Yes
Yes
Yes
Yes
4
Power Button
Data Hold
Button
LCD Display
NCV/LINE LED
Indicator
Induction Indicator
Backlight Button
Rotary Switch
COM Input Jack
Input Jack 10A Input Jack
The tilt stand & battery compartment are at the rear of the multimeter.
5
FUNCTIONS
NCV Detection
Hold Button
LED Indicator
LCD Display
Backlight Button
Auto Backlight
Low Battery
Rotary Switch
Input Jacks
Move the rotary switch to NCV. When voltage is detected, the alarm will sound and the LED indicator will flash.
Press the button to lock readings as displayed on screen. Press again to unlock.
Flashes when voltage is detected.
Readings and measurements taken by the multimeter appear in this area.
Press to turn the backlight on. Light will remain on for approximately 10 seconds.
In low light conditions, the LCD Display backlight will automatically turn on.
The battery icon will appear on screen when battery power is low and the battery needs replacing.
Select a measurement range by turning the switch to the preferred option.
• V/ΩmA
• COM
• 10A: Input terminal for 10A current.
6
AC & DC VOLTAGE MEASUREMENT
To avoid electric shock and/or damage to the multimeter - do not attempt to take any voltage measurements that might exceed 600VDC and do not apply more than 600VDC between the common terminal and the earth ground. Unstable display may occur, especially at the low voltage range measurement. If an erroneous reading is suspected, short the V/ΩmA jack and COM jack, and make sure zero is displayed on screen.
1) Set the rotary switch to the voltage position (V /V~).
2) Insert the black test lead banana plug into the negative COM jack.
3) Insert the red test lead banana plug into the positive V/ΩmA jack.
4) Touch the black test probe tip to the negative side of the circuit.
5) Touch the red test probe tip to the positive side of circuit.
6) Read the voltage on screen. The polarity of the red test lead will display when taking the DC Voltage measurement.
CURRENT MEASUREMENT
Use the proper terminals, function and range for any current measurement. Never attempt measurement if potential for an open circuit to earth is greater than 250V. Do not place the test leads in parallel with a circuit or component when the test leads are plugged into the current terminals.
1) Disconnect power from the circuit to be tested and discharge the capacitors.
2) Set the rotary switch to current measuring range.
3) For current measurements:
• less than 200mA, insert the black test lead banana plug into the negative COM jack.
• between 200mA to 10A, insert the red test lead banana plug into the mA jack.
4) To break the circuit under test, connect the black test lead to the more negative side of the break, and connect the red test lead to the more positive side of the break.
5) Connect power to the circuit being tested and read the value on screen. If OL displays, the input is over range - so you will need to select the higher range.
6) Disconnect power from the circuit to be tested, then discharge all capacitors. Remove the test leads and recover the measured circuit.
7
DIODE TEST & CONTINUITY CHECK
To avoid electric shock - disconnect power to the unit under test and discharge all capacitors before taking the diode test, and never measure continuity on circuits of wires that have voltage on them. In a circuit, a good diode should produce a forward bias reading of voltage. However, the reverse-bias reading can be variable based on the resistance of other pathways between the probe tips.
DIODE TEST
1) Set the rotary switch to the position.
2) Insert the black test lead banana plug into the negative COM jack.
3) Insert the red test lead banana plug into the positive VΩmA jack.
4) Place the red test lead on the anode of diode and black test lead on the cathode of the diode. The meter will show the approx. forward voltage of the diode. Reverse voltage will indicate OL.
CONTINUITY CHECK
Touch the test probe tips to the circuit or wire you wish to check. The maximum value of resistance under check will appear on the screen. If the resistance is less than 30Ω, the audible signal will sound.
RESISTANCE MEASUREMENT
To avoid electric shock - disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements.
Remove the batteries and unplug the line cords. The measured value of a resistor in a circuit is usually different from the rated value of a resistor. This is because the test current of the meter flows through all possible paths between the probe tips. In order to ensure the best accuracy when measuring low resistance, short the test leads before the measurement and subtract this resistance value from the total. For high resistance measurements, the meter may take a few seconds to stabilise the readings. In an open circuit, the meter will display OL to indicate over range.
1) Set the rotary switch to the Ω position.
2) Insert the black test lead banana plug into the negative COM jack.
3) Insert the red test lead banana plug into the positive VΩmA jack.
8
4) Touch the test probe tips across the circuit or the part under test. It’s best to disconnect one end of the circuit, so the rest of the circuit will not interfere with the resistance reading.
5) Read the resistance displayed on-screen.
SQUARE WAVE OUTPUT
1) Set the rotary switch to range position.
2) Insert the black test lead banana plug into the negative COM jack.
3) Insert the red test lead banana plug into the VΩmA jack.
4) The meter output square wave: frequency = 50Hz ±10Hz, Vp-p =
5V±2V, output impedance = 560kΩ.
NCV (NON-CONTACT VOLTAGE) DETECTION
Due to external interference sources, this test may detect the wrong voltage. Please use as an estimate only. Socket design, insulation thickness and other variable conditions may interfere with detection.
External sources such as flashlights, motors, etc may interfere with reading and cause the wrong detection.
1) Set the rotary switch to NCV position and wait for EF to display
on screen.
2) Contact the top part of the meter with the circuit being tested.
3) The LED light will flash and an audible signal will sound, with the signal strength displayed on screen.
LINE (LIVE WIRE RECOGNITION) TEST
When serious circuit leakage is detected (approx. over 15V) and the red test lead is in contact with the earth line, the meter will buzz and the LED light will flash.
1) Set the rotary switch to LINE position.
2) Connect the black test lead to the COM jack and red test lead to the
VΩmA jack. Make sure to hold the insulation part of the black test lead and not plug it into the circuit under measurement.
3) Contact the red test lead to the wire. If it’s live, the meter’s buzzer will sound and the red LED will flash.
4) If an earth connection is detected, the buzzer will not sound and the
LED light will not flash.
9
MEASUREMENT SPECIFICATIONS
The following guide is based on an environmental temperature of
18-28°C and humidity <80%.
DC VOLTAGE
RANGE
200mV
2V
20V
200V
500V
RESOLUTION
100µV
1mV
10mV
100mV
1V
ACCURACY
±(0.5% reading + 2 digits)
±(0.5% reading + 3 digits)
±(0.8% reading + 3 digits)
±(0.8% reading + 5 digits)
Overload Protection: 200mV range at 250VDC or 250VAC RMS
Other ranges at 600VDC or 600VAC RMS
AC VOLTAGE
RANGE
200V
500V
RESOLUTION
0.1V
1V
ACCURACY
±(1.8% reading + 10 digits)
Overload Protection: 500VDC or 500VAC RMS
Frequency Range: 40~400Hz
10
DC CURRENT
RANGE
200µA
2mA
20mA
200mA
10A
RESOLUTION
0.1µA
1µA
10µA
100µA
10mA
Overload Protection: Fuse F200mA/250V
No fuse for 10A range
ACCURACY
±(1.0% reading + 5 digits)
±(2.0% reading + 5 digits)
±(3.0% reading + 5 digits)
SQUARE WAVE OUTPUT
OUTPUT
FREQUENCY
50Hz ±10Hz
VP-P
5V±2V
IMPEDENCE
560kΩ
RESISTANCE
RANGE
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
RESOLUTION
0.1Ω
0.001kΩ
0.01kΩ
0.1kΩ
0.001MΩ
ACCURACY
±(1.0% reading + 2 digits)
Overload Protection: 250VDC or 250VAC RMS
Maximum Open Circuit Voltage: <3.2V
11
DIODE & CONTINUITY
RANGE FUNCTION
Display approximate forward voltage of diode
Built-in buzzer will sound if resistance is less than 70Ω ± 30Ω
MAINTENANCE
BATTERY INSTALLATION
To avoid false readings, replace the battery as soon as the low battery power indicator appears.
1) Turn power off and disconnect the test leads from the meter.
2) Open the rear battery cover with a screwdriver.
3) Remove the old battery and insert the new battery into the battery holder, observing the correct polarity.
4) Put the battery cover back in place and secure with the screws.
REPLACING THE FUSES
1) Turn power off and disconnect the test leads from the meter.
2) Remove the battery cover and battery.
3) Remove the screws securing the rear cover.
4) Gently remove the old fuse and install the new fuse into fuse holder.
5) Replace and secure the rear cover, battery and battery cover.
12
SPECIFICATIONS
Protection: Overload, Full Range
Max. Input Voltage: 600VDC
Operating Temperature: 0°C~40°C
Operating Humidity: < 80%RH
Storage Temperature: -10°C~60°C
Storage Humidity: < 70%RH
Power Supply:
Dimensions:
Weight:
1 x 9V Battery
145(H) x 70(W) x 32(D)mm
200g (including battery)
BOX CONTENTS
1 x Non-Contact Voltage Detection Multimeter
1 x Test Leads
1 x Holster
1 x 9V Battery
1 x User Manual
13
WARRANTY
This product is protected by a 2 year warranty (from the date of purchase) covering all product manufacturing defects/faults that may occur within this timeframe. This warranty does not cover damage caused by neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or handling, including failures caused by use outside of the product’s specifications, or the normal wear and tear of mechanical components.
In the event that you suspect your product is defective/faulty, cease using the product when the suspected defect/fault arises and return the product along with proof of purchase to the place of purchase or distributor for assessment. Distributor contact details are available on the last page of this manual.
If the assessment concludes that the product is indeed defective/faulty, the product will either be repaired or replaced at no cost to you.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
14
THIS PAGE INTENTIONALLY LEFT BLANK
15
Distributed by:
Electus Distribution Pty. Ltd.
320 Victoria Rd, Rydalmere
NSW 2116 Australia www.electusdistribution.com.au
Made in China
Herunterladen
Werbung