INSTALLATION INSTRUCTION
EH-17
Outer ventilation hood
EH-17
PURPOSE
The outer ventilation hood is designed to prevent ingress of water and foreign objects into the ventilation equipment from outside.
THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED
PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT
THE APPROPRIATE TRAINING.
THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED
PERSONNEL AFTER THE APPROPRIATE BRIEFING.
THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED
ACCESS BY UNATTENDED CHILDREN.
OVERALL DIMENSIONS
A B
A1
øD
H
H1
Model
EH-17
øD1
Ø D Ø D1
Dimensions [mm]
A A1 B H H1
106 (4 3 /
16
") 164 (6 7 /
16
") 212 (8 3 /
8
") 160 (6 5 /
16
") 60 (2 3 /
8
") 260 (10 1 /
4
") 160 (6 5 /
16
")
OUTER VENTILATION HOOD MOUNTING
1. Insert the air duct from indoor to protrude from outside on the outer wall surface. Cut the air duct excess and a stream spreader with a hack saw or with any other suitable tool.
WARNING! If the mounting place is located at high altitude, please refer to a mounting.
( 1 /
8
’’)
2 www.ventilation-system.com
2. Mark the fastening holes for the outer ventilation hood and drill
4 holes, 50 mm (1 15/16”) deep to suit the expansion anchors (6x40).
Use the back wall of the ventilation hood to facilitate the marking.
155
(6 1 /
8
")
3. Insert the supplied expansion anchors 6x40 into the holes.
Remove the outer ventilation hood to enable access to the fastening holes. Pull the front part below toward you.
155
(6 1 /
8
")
ø6 ( 1 /
4
")
4 holes
4. To install an air duct with a diameter of 160 mm (6 5/16”), remove the adapter on the back wall.
5. Fix the rear part and the rainwater inlet of the ventilation hood to the wall using the supplied 4 x 40 screws.
6. Cover the ventilation hood with the front part.
www.ventilation-system.com