Advertisement
Advertisement
Planning Information
Models DD45 I and DD45 R Downdraft Systems
Top cover
Model DD45I
Internal Blower
Model DD45R
In-Line or
Remote Blower
9" (229) chimney elevation
Three-speed blower control
Aluminum mesh filters
Stainless steel filter covers
Remote-mounted control module
Location of rating plate
Model DD45I 45" (1143) downdraft ventilation system includes a 500 CFM internal blower. In-line and remote blower options are available for Model DD45R.
Control module and top cover come in classic stainless steel only and are included with the downdraft.
T
he cooktop downdraft unit rises from the countertop to whisk away odors and smoke into the easy-to-clean, five-layer mesh filter. The control module and top cover come in classic stainless steel only and are included with the downdraft.
Wolf downdraft ventilation systems are recommended for use with Wolf electric and gas cooktops and integrated modules, excluding the unframed electric cooktops and electric grill, steamer and fryer modules.
Wolf downdraft systems cannot be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops.
Dimensions in parentheses are in millimeters unless otherwise specified.
9/06
1
Planning Information
Models DD45 I and DD45 R Downdraft Systems
F E A T U R E S
Control module and top cover are available in the classic stainless steel finish only
Remote-mounted control module
Internal, in-line and remote blower options
Three-speed blower control
Filter clean timer lets you know when the filter needs cleaning
Delay-off feature automatically turns unit off, chimney remains up
Stainless steel filter cover with dishwasher safe aluminum mesh filter
LED indicators
9" (229) chimney elevation
Control module, top cover, mounting brackets, DIN connector and necessary hardware included with the downdraft
UL listed to US and Canadian safety standards
Two and five year residential warranty – exclusions apply; warranty information can be found on our website, wolfappliance.com
O V E R A L L D I M E N S I O N S
45 1 / 2 "
(1156)
9 1 / 16 "
(230) 41 1 / 4 "
(1048)
1 1 / 2 " (38)
DEPTH OF
DOWNDRAFT CHIMNEY
2 3 / 8 "
(60)
Dimensions may vary by ± 1 /
8
" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
2
Planning Information
Models DD45 I and DD45 R Downdraft Systems
M O D E L O P T I O N S
Downdraft with 500 CFM
Internal Blower Included
Downdraft Only — In-Line or
Remote Blower Required
DD45I
DD45R
Control module, top cover, mounting brackets, DIN connector and mounting hardware included with the downdraft.
For Model DD45R see in-line and remote blower options below.
B L O W E R O P T I O N S
1100 CFM In-Line Blower 808332
900 CFM Remote Blower 801641
1200 CFM Remote Blower 801642
1500 CFM Remote Blower 804701
Refer to the Wolf Cooktop Ventilation
Recommendations chart at the end of this section.
A C C E S S O R I E S
Transitions in various sizes
Accessories are available through your
Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
S P E C I F I C A T I O N S
Overall Width
Overall Height (above countertop)
Overall Depth
Duct Size (Model DD45I)
Duct Size (Model DD45R)
45 1 /
2
" (1156)
9 1 /
16
" (230)
2 3 /
8
" (60)
3 1 /
4
" (83) x 10" (254)
3 1 / 4 " (83) x 14" (356)
Discharge Adjustable
Electrical Supply Requirements
Power Cord
110 /120 V AC, 60 Hz
15 amp dedicated circuit
2 1 / 2 ' (.8 m) power cord with
3-prong grounded plug
Shipping Weight 85 lbs (39 kg)
Specifications are subject to change without notice.
Dimensions in parentheses are in millimeters unless otherwise specified.
C O U N T E R T O P C U T - O U T
25 1/8 " MIN
(638)
FLAT
COUNTERTOP
SPACE
2 3/4 " (70)
42" (1067)
COOKTOP CUT-OUT
WIDTH
2 1/2 " MIN
(64)
19 1/4 "
(489)
3
Planning Information
Models DD45 I and DD45 R Downdraft Systems
1 3/4 " MIN (45)
BACK EDGE
OF COOKTOP
TO INSIDE OF
CABINET BACK*
.344"
29 5/16 "
(745)
COUNTERTOP
TO BOTTOM OF
AIR BOX
25 1/8 " MIN (638)
OF FLAT COUNTERTOP*
5/8 "
(16) 19 1/4 " (489)
COOKTOP CUT-OUT
DEPTH
2 3/8 " (60)
2 1/8 " (54)
3 1/4 "
(83)
7 11/16
(197)
"
5"
(127)
18"
(457)
3 5/8 "
(92)
2 1/2 " MIN
(64)
WITH NO
RAISED LIP*
36"
(914)
7 1/8 "
(181)
24" MIN (610)
CABINET DEPTH
*AREAS OF POTENTIAL INTERFERENCE
L O C A T I O N O F E L E C T R I C A L
24 " min (610)
CABINET DEPTH
4" min (102)
3 1 / 2 " (89) E
10" (254)
ELECTRICAL LOCATION
IN CABINET BACK
45 1 / 2 " min (1156)
E
OPTIONAL
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
D I M E N S I O N S
Downdraft Cut-Out Width
Minimum Cabinet Width
Downdraft Cut-Out Depth
Location of Electrical
See Installation Instructions shipped with unit for detailed specifications.
42" (1067)
45 1 /
2
" (1156)
2 3 / 4 " (70)
Within shaded area
Dimensions in parentheses are in millimeters unless otherwise specified.
4
Planning Information
Models DD45 I and DD45 R Downdraft Systems
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions and installation specifics.
Wolf downdraft ventilation systems are recommended for use with Wolf electric and gas cooktops and integrated modules, excluding the grill, steamer and fryer modules. The downdraft should be at least as wide as the cooking surface.
IMPORTANT NOTE: Wolf downdraft ventilation systems cannot be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops. A Wolf Pro ventilation hood should be used.
The 45" (1143) downdraft will fit most 45"
(1143) wide cabinets. Cabinet backs may need to be removed. It is recommended that oversized cabinets be used for easier installation.
To incorporate a downdraft system and a
Wolf cooktop, you must allow for a minimum
25 1 /
8
" (638) flat counter space from front to back. A countertop with a raised lip and/or backsplash may not allow enough space for proper installation. 2 3 / 8 " (60) of flat countertop is required behind the cooktop and 1 3 /
4
" (44) is necessary between the back edge of the cooktop and inside of cabinet back. Follow dimensions given in the Countertop Cut-out illustration on page 3.
Model DD45I has a 500 CFM internal blower.
Model DD45R is shipped without the blower assembly. In-line and remote blower assemblies are available. Blower options vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for cooktop ventilation recommendations and blower options.
IMPORTANT NOTE: Install this downdraft only with a Wolf blower.
Wolf downdraft ventilation systems require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the 2' (.6 m) power cord. The specific location of the outlet is not critical, as long as it is within reach of the power cord that is located mid-way, top and bottom on the right side of the downdraft.
If the 45" (1143) downdraft is being installed in a 45" (1143) wide cabinet, the outlet cannot be located on the back wall of the cabinet. It is recommended that the outlet be placed in an adjacent cabinet within reach of the power cord. Refer to the Location of Electrical illustration on page 4.
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
This appliance must be used with a Wolf approved remote mounted control module and top cover, which is included with the downdraft.
Installation of the control module must be within 10' (3 m) of the downdraft assembly and a minimum of 4" (102) from the outer edge of cooktop element or burner. You will be required to drill three holes and connect the two units by the provided wire.
Refer to the installation instructions shipped with each Wolf product for detailed specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Planning Information
Models DD45 I and DD45 R Downdraft Systems
D U C T I N G C O N S I D E R A T I O N S
Except for Models DD30I, DD36I and DD45I, which include a 500 CFM internal blower, Wolf downdrafts are shipped without the blower assembly. In-line and remote blower assemblies are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
IMPORTANT NOTE: Install this downdraft ventilation system only with a Wolf blower.
Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles.
Three different discharge locations are available with side to side adjustment for accurate alignment of ductwork. Refer to the illustration below for discharge location options.
Discharge location options for internal and remote blower models.
CENTERLINE OF COUNTERTOP CUTOUT
16 3/8 "
(416)
INTERNAL BLOWER
21 1/2 "
(546)
REMOTE BLOWER
CL
22 1/8 "
(562)
INTERNAL BLOWER
19"
(483)
REMOTE BLOWER
LEFT
DISCHARGE
LOCATION
CENTERLINE OF COUNTERTOP CUTOUT
RIGHT
DISCHARGE
LOCATION
5
1/2
" (140)
INTERNAL BLOWER
4
1/4
" (108)
REMOTE BLOWER
DISCHARGE CUTOUT
DIMENSIONS:
10 1/4 "
(260)
x 3 1/2 "
(89)
INTERNAL BLOWER
14 1/4 "
(362)
x 3 1/2 "
(89)
REMOTE BLOWER
ADJUSTMENT:
5" MAX (127)
REMOTE BLOWER
CL
ADJUSTMENT:
1" (25) - 7" (178)
INTERNAL BLOWER
2 1/2 "
MAX (165)
REMOTE BLOWER
BOTTOM
DISCHARGE
LOCATION
5
1/2
" (140)
INTERNAL BLOWER
4
1/4
" (108)
REMOTE BLOWER
NOTE: Measurements are to centerline of duct cutouts
Dimensions in parentheses are in millimeters unless otherwise specified.
6
Planning Information
Models DD45 I and DD45 R Downdraft Systems
D U C T I N G C O N S I D E R A T I O N S
For best performance, 10" (254) round ductwork is recommended. The downdraft will operate most efficiently when ductwork does not exceed
40' (12 m) in length. Consult a qualified HVAC engineer for specific ducting applications.
IMPORTANT NOTE: All Wolf downdrafts must be vented to the outside. Use only metal ductwork.
Choose the ducting option that allows the shortest length of ductwork and a minimum number of elbows and transitions. Refer to the illustration below for ducting options.
Refer to the cooktop ventilation charts at the end of this section for recommendations and blower options.
Ducting options for downdraft Models DD45I and DD45R.
10"
ROUND
REMOTE
BLOWER
WALL CAP
12"
MIN
TO
GROUND
INTERNAL BLOWER
INSTALLATION THROUGH WALL
REMOTE
BLOWER
10"
ROUND
REMOTE BLOWER
ROOF MOUNT INSTALLATION
12" MIN
TO
GROUND
12" MIN
TO
GROUND
INTERNAL BLOWER
INSTALLATION THROUGH WALL
REMOTE BLOWER
INSTALLATION THROUGH WALL
Dimensions in parentheses are in millimeters unless otherwise specified.
7
Planning Information
Wolf Ventilation Recommendations
W O L F B L O W E R A S S E M B L I E S
A ventilation system must include a blower assembly. With a few exceptions where internal blowers are included, Wolf ventilation hoods and downdrafts are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer.
Wolf internal, in-line and remote blowers are for use with Wolf cooktop hoods, downdraft systems and Pro ventilation hoods and hood liners.
IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products.
Internal blowers are mounted inside the hood canopy or downdraft blower box. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers.
Ventilation recommendation charts on the following pages provide minimum CFM recommendations according to the cooking appliance and ventilation system used and blower options for each specific ventilation hood or downdraft.
24 3 / 8 "
(619)
11 3 /
4
"
(298)
18 1 / 2 "
(470)
4
1
/ 2 "
(114)
21
1
/ 2 "
(546) 12
1
/ 4 "
(311)
24
7/8
"
(632)
18"
(457)
12"
(305)
22"
(559)
8"
(203)
18"
(457)
In-line BLOWER-60IL In-line BLOWER-110IL
28 1/4 "
(718)
15
1/2
"
(394)
10" (254)
Diameter
20 3/4 "
(527)
24 1/2 "
(622)
29
1/2
"
(749)
14 3/4 "
(375)
10" (254)
Diameter
18"
(457)
10"
(254)
29 1/2 "
(749)
14"
(356)
24 3/4 "
(629)
4
3/4
"
(121)
10
1/8
"
(257)
22"
(559)
Remote BLOWER-60REM and
BLOWER-90REM
Dimensions may vary by ± 1 /
8
" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
Remote BLOWER-120REM
7 1/4 "
(184)
29 1/2 "
(749)
14
3/4
"
(375)
10"
(254)
Diameter
21"
(533)
10"
(254)
29 1/2 "
(749)
10
3/8
"
(264)
25"
(635)
Remote BLOWER-150REM
7 1/4 "
(184)
8
Planning Information
Wolf Cooktop Ventilation Recommendations
C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O N S
Cooktop Hoods, Downdrafts and Pro Hoods
CTWH30 CTWH36
Electric Cooktops
Model CT15E
Model CT30E
Model CT30EU
Model CT36E
Model CT36EU
215*
450
450
215*
600
600
600
600
IH4227
215*
600
600
600
600
DD30
215*
500
Gas Cooktops
Model CT15G
Model CT30G
Model CT36G
CTWH30 CTWH36 IH4227
215*
450
215*
600
600
215*
600
600
DD30
215*
500
DD36
500
DD36
DD45
150*
350
Pro Hoods
215*
600
600
600
600
DD45 Pro Hoods
150*
350
215*
600
600 500
CTWH30 CTWH36 IH4227 DD30 DD36
Modules
Model CT15I
Model IG15
Model IS15
Model IF15
Model IM15
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
*Use these requirements to determine total CFM when installing multiple cooktops or modules.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW).
Additional CFM may be required for long duct runs.
DD45
150*
150*
Pro Hoods
215*
215*
215*
215*
215*
C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S
Downdraft Systems
Blower Description
500 CFM Internal
1100 CFM In-Line
900 CFM Remote
1200 CFM Remote
1500 CFM Remote
Blower Number
Included with (I) Models
BLOWER-110IL (808332)
BLOWER-90REM (801641)
BLOWER-120REM (801642)
BLOWER-150REM (804701)
Downdraft Models
DD30I / DD36I / DD45I
DD30R / DD36R / DD45R
DD30R / DD36R / DD45R
DD30R / DD36R / DD45R
DD30R / DD36R / DD45R
Adjustable discharge. 3 1 /
4
" (83) x 10" (254) duct for internal blower, no transition required. 3 1 /
4
" (83) x 14" (254) duct for in-line and remote blowers. TRANS-14-10 required for remote blowers.
Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product.
Always consult a qualified HVAC Engineer for specific applications.
Dimensions in parentheses are in millimeters unless otherwise specified.
9
Advertisement