INTRODUCTION
SYSTEM DESCRIPTION
MODES OF OPERATION, FUNCTIONS AND FEATURES
ON-UNIT INDICATORS AND CONTROLS
On-unit Operation
PROTECTION MODES
CARE AND MAINTENANCE
OPERATING TIPS
PRECAUTIONS
BEFORE CALLING FOR SERVICE
INTRODUCTION
Dear customer:
The DC Inverter air conditioner you have purchased is one of the most advanced units of its kind. The DC Inverter air conditioner is a variable capacity air conditioner which uses high efficiency DC motors for the compressor and the outdoor fan. Unlike other models, it can adjust its capacity according to the user setting and the environmental condition, thus saving up to 30% of the seasonal power consumption, while keeping maximum comfort level. This modern unit is also equipped with an ionizer (optional) and an Electrostatic filter (optional) to maximize your indoor air quality.
Detailed instruction as to the DC Inverter air conditioner (including
Single & Multi Split type) functions and way of operation are provided in the following pages.
This Split Air Conditioner is designed for versatile application:
Cooling.
Dehumidifying.
Heating.
Air Filtration.
Ventilation
AUTO
OPERATING TEMPERATURE
RANGE:
IMPORTANT NOTICE:
This air conditioner must be grounded to protect against electrical shock.
Installation of the air conditioner must be performed by an experienced air conditioning installer, observing good refrigeration practice.
Electrical connections and power cord replacement should only be made by authorized electricians and in accordance with electrical regulations and local codes. The applicance must be positioned so that the plug is accessible.
Failure to comply with the manufacturer's installation and operation instructions could affect the performance of the air conditioner and the validity of the warranty.
Test Mode
Test Mode is set only for performance testing purposes, and not for user operation. Test mode can be initiated by either one of the following conditions:
1) Operating the unit with the following remote control settings and temperature conditions:
Cool Mode, SPT=16 and
RAT=27 1
OAT=35 1 for 30 minutes;
Heat Mode, SPT=30 and
RAT=20 1 ,
OAT=7 1 for 30 minutes. 2)
Entering Diagnostics with
Cool/SPT=16 or
Heat/SPT=30 .
1
2
14
1
2
3
4
5
6
AUTO
15 16 17
7
8
9
13
10
11
12
Designed to create comfortable sleeping conditions. When in COOLING mode, the temperature rises one degree centigrade after each consecutive hour, up to three hours, from the start of the mode. The temperature rise prevents the feeling of over-cooling while sleeping (when your body is at rest). In HEATING mode the reverse occurs; the air conditioner lowers its temperature one degree every hour, up to three hours, from the start of the mode. When in SLEEP mode, the air conditioner will be automatically turned off after operated for seven hours.
The result is a more comfortable and invigorating sleep, which leaves you feeling fresh and energetic in the morning.
3
4
Automatic swing of Horizontal air flow in Horizontal direction. The flap move automatically in right and left direction to spread the conditioned air evenly throughout the room.
Filter indicator on the indoor unit display is turned on when the filter requires cleaning. After cleaning and reinstalling the filter, It should be reset.
A B C D
J
K
L
I
M
N
E F
G
ESF-PWR
COOL
RESET
HEAT
MODE
ESF-EN
H
On-unit Operation
If the air-conditioner can not be operated by the Remote
Control unit, it can be turned on for cooling or heating, or completely turned off, by pressing MODE button (M) on the air-conditioner. The MODE button will change the operating status of the unit between - COOLING - HEATING -STAND BY positions. Every time MODE button (M) is pressed, (J) or (L) will light up respectively, to indicate in which mode the air-conditioner operates.
A. Stand-by Operation indicator
Lights up in red when connected to power. Lights up in green during operation.
B. ESF/ Ionizer/Fresh air indicator
Lights up during the ESF or lonizer or Fresh air operation.
(optional)
C. LCD operation display
D. Timer indicator
Lights up during timer and sleep operation.
E. Filter indicator
Lights up when air filter requires cleaning.
F. Signal receiver
Receive signals from the remote control.
G. Ionizer indicator
Lights up during ionizer operation
H. Ionizer on/off switch
Used to switch the ionizer on/off.
I. Electrostatic filter operation button
Used to switch the Electrostatic filter on or off
J. Cooling indicator
Lights up only when Mode (M) is pressed.
K. Reset button
Press to turn off the filter indicator and to reset the filter function, after the cleaned filter has been reinstalled.
Press to cancel the buzzer announcer.
L. Heating indicator
Lights up only when Mode (M) is pressed.
M. Unit mode button
Used to switch the unit off or to turn it on for cooling or heating without the remote control.
N. Electrostatic filter safety button
Turn off the Electrostatic filter when you open the grille.
5
AUTO
K
The electronic filter should be removed from the unit and cleaning once three month. The procedure is shown as following:
The air purifying filter should be removed from the
AUTO
7