ABB EDEN is a non-contact safety sensor for use on interlocked gates and hatches. It features a dynamic signal transmission between two separate devices (Adam and Eva) with a maximum sensing distance of 15 mm +/- 2 mm. Connect up to 30 sensors to Vital or 10 sensors per input to Pluto while maintaining the same safety level. It also allows for the integration of safety light beams, Tina adaptor units, and E-stops on the same safety circuit. Ideal for harsh environments, its protective housing provides IP69K protection.
advertisement
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Original instructions
Eden
Non-contact safety sensor
ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Read and understand this document
Please read and understand this document before using the products. Please consult your ABB JOKAB SAFETY representative if you have any questions or comments.
WARRANTY
ABB JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ABB JOKAB SAFETY.
ABB JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED,
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF
THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED
USE. ABB JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED.
LIMITATIONS OF LIABILITY
ABB JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
IN NO EVENT SHALL ABB JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS ABB
JOKAB SAFETY’S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
ABB JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, ABB
JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE ABB JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
While every effort has been taken to ensure the accuracy of the information contained in this manual ABB JOKAB
SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and improvements without notice. Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of ABB JOKAB SAFETY’S test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the ABB JOKAB SAFETY Warranty and Limitations of Liability.
2TLJ172066M0201, rev. F
2015-02-09
2 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Table of Contents
Read and understand this document ........................................................................................................................ 2
1 Introduction ......................................................................................................................................... 4
Scope ........................................................................................................................................................................ 4
Audience ................................................................................................................................................................... 4
Prerequisites ............................................................................................................................................................. 4
Special notes ............................................................................................................................................................ 4
2 Overview .............................................................................................................................................. 5
General description ................................................................................................................................................... 5
Safety regulations ..................................................................................................................................................... 5
3 Connections ........................................................................................................................................ 6
Connection examples ............................................................................................................................................... 7
4 Installation and maintenance ............................................................................................................. 9
Installation precautions ........................................................................................................................................... 10
Maintenance ........................................................................................................................................................... 11
Testing of the safety functions ................................................................................................................................ 11
Troubleshooting ...................................................................................................................................................... 11
5 Operation ........................................................................................................................................... 12
LED indication ......................................................................................................................................................... 12
Information output signal attributes......................................................................................................................... 12
6 Model overview .................................................................................................................................. 13
Accessories ............................................................................................................................................................. 13
7 Technical data ................................................................................................................................... 14
8 EC Declaration of conformity ........................................................................................................... 17
2TLJ172066M0201, rev. F
2015-02-09
3 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
1 Introduction
Scope
The purpose of these instructions is to describe the non-contact safety sensor Eden and to provide the necessary information required for installation and operation.
Audience
This document is intended for authorized installation personnel.
Prerequisites
It is assumed that the reader of this document has knowledge of the following:
Basic knowledge of ABB Jokab Safety products.
Knowledge of machine safety.
Special notes
Pay attention to the following special notes in the document:
Warning!
Danger of severe personal injury!
An instruction or procedure which, if not carried out correctly, may result in injury to the technician or other personnel.
Caution!
Danger of damage to the equipment!
An instruction or procedure which, if not carried out correctly, may damage the equipment.
NB: Notes are used to provide important or explanatory information.
2TLJ172066M0201, rev. F
2015-02-09
4 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
2 Overview
General description
Eden is a non-contact safety sensor consisting of two separate devices
– Adam and Eva – for use on interlocked gates, hatches etc. A dynamic signal is transmitted from the control device Vital or safety-PLC Pluto via Adam to
Eva who sends it back again. The maximum sensing distance between Adam and Eva is 15 mm +/- 2 mm. Up to
30 Eden sensors can be connected to Vital and 10 Eden sensors per input can be connected to Pluto and still achieve the same safety level on the safety circuit. It is also possible to connect safety light beams, Tina adaptor units and E-stops on the same safety circuit.
Adam is available with an M12-connector or with an integrated cable of up to 20 m. Eden E is designed for harsh environments and with its protective housing it achieves protection class IP69K (maximum sensing distance for
Eden E is 12 mm +/- 2 mm).
The Jokab Safety branded product with articlenumber beginning with 2TLJ is fully compatible with the ABB branded product with articlenumber beginning with 2TLA.
Safety regulations
Warning!
Carefully read through this entire manual before using the device.
The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine directive.
Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions, improper installation or handling of the device can affect the safety of people and the plant.
For installation and prescribed use of the product, the special notes in the instructions must be carefully observed and the technical standards relevant to the application must be considered.
In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the product, any liability is excluded.
NB: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
2TLJ172066M0201, rev. F
2015-02-09
5 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
3 Connections
Eden electrical connections
M12-connector:
(5-pole male)
1 ) Brown:
2 ) White:
3 ) Blue:
4 ) Black:
5 ) Grey:
+24 VDC
Dynamic signal input
0 VDC
Dynamic signal output
Information output
M12 5-pole male seen from cable side
M12 5-pole female seen from cable side
NB: Shielded cable is recommended between this unit and the rest of the safety circuit.
Caution! All cable colours according to ABB Jokab Safety standard cables.
Warning! Eden is equipped with an information output able to indicate the status of the sensor. The information channel output is non-safe and should never be used for the safety function. The only signals intended for safety functions are the safe dynamic signals.
2TLJ172066M0201, rev. F
2015-02-09
6 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Connection examples
Connection example: Two Eden and one Spot T/R connected to Pluto safety-PLC
ABB
Caution! All cable colours according to ABB Jokab Safety standard cables.
2TLJ172066M0201, rev. F
2015-02-09
7 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Connection example: Different sensors connected to Vital 1 safety module
Caution! All cable colours according to ABB Jokab Safety standard cables.
2TLJ172066M0201, rev. F
2015-02-09
8 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
4 Installation and maintenance
Eva can be turned in a number of different ways relative Adam, see details in the figure below. Depending on the cable connector used to connect to Eden, different distance plates can be necessary in order to avoid damage to
Adam. The protection plates (DA1) supplied with Adam M12-models are recommended for this, see figure below.
Also, the mounting spacers supplied must be used in order to physically protect Eden from damage.
Use two M4-screws to fasten each sensor. Safety screw SM4x20 (Eden) and SM4x25 (Eden E) are recommended.
Use max tightening torque 2 Nm. Lock screw using Loctite or similar to prevent easy dismounting if necessary
(refer to risk assessment).
Eden installation
Mounting tolerances
The DA2 mounting spacer must be used in order to physically protect Eden from damage.
Mounting Adam with integral cable.
Mounting with one protection plate (DA1) for Adam M12 using prewired moulded M12 connector
Mounting with two protection plates (DA1) for Adam M12 using M12 connector with glanded cable.
Incorrect mounting without protection plate may cause permanent damage to sensor.
Maximum sensing distance between Adam and Eva:
Minimum distance between two Eden pairs:
Eden: 15 mm +/- 2 mm
Eden E: 12 mm +/- 2 mm
50 mm
2TLJ172066M0201, rev. F
2015-02-09
9 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Cable mounting
The cable should be mounted so there is no force on Adam sensor in any directions. The cable should be fixed if it’s connected to a moving object, for example a cable chain or a door. This can be done with for example two cable clamps. This applies to all versions of Adam, including Adam E and Adam with M12-contact.
An improperly installed cable can damage the sensor.
Minimum safety distance
When using interlocking guards without guard locking to safeguard a hazard zone, the minimum allowed safety distance between the guarded opening and the hazardous machine must be calculated. In order to ensure that the hazardous machine motion will be stopped before it can be reached, the minimum safety distance is calculated according to EN ISO 13855 (“Positioning of safeguards with respect to the approach speeds of parts of the human body”).
The minimum safety distance is calculated according to the formula:
S = (K x T) + C
Where
S = minimum safety distance (mm)
K = approach speed of a human body; 1600 mm/s
T = the total time from opening of the guard until the hazardous machine movement has stopped, i.e. including control system reaction times and other delays (s)
C = a safety distance taken from Table 4 or Table 5 of EN ISO 13857:2008, if it is possible to push fingers or a hand through the opening towards the hazard before a stop signal is generated
NB: In some cases, T might be reduced by the opening time of the guard until the opening size permits access of the relevant parts of the body. Refer to EN ISO 13855 for further details and EN ISO 13857 for specified values.
Installation precautions
Note that the sensing distance may change when the sensor is fitted onto metals. Mount Adam and Eva to the intended operating position and test and adjust the sensing distance. Distance plates DA1 can also be used between the sensor and mounting bracket to avoid direct contact with the metal.
Use max tightening torque 2 Nm when mounting the sensors.
Control that Adam and Eva are aligned in parallel to each other.
The cable to Adam should be U-shaped if the units are mounted in wet areas.
Warning!
All the safety functions must be tested before starting up the system.
2TLJ172066M0201, rev. F
2015-02-09
10 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Maintenance
Warning!
The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safety functions are working properly (EN 62061:2005).
In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety Service Office or reseller.
Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
Testing of the safety functions
Make sure the safety unit is working properly by following these steps:
Interrupt protection by moving Eva away from Adam. The LED will light red when Eva is out of position relative Adam.
Interrupt the dynamic safety circuit before this unit. The LED will flash between green and red.
Move Eva to position next to Adam. The LED will light green if the safety circuit(s) before this unit is not interrupted.
An additional function test can be made by slowly moving Eva away from Adam. The LED will flash fast between green and red when Eva is 2 mm from max sensing distance to Adam.
Troubleshooting
LED indication
Lights red
Expected causes of faults Checking and measures to take
Eva away
Metal (iron) between Eden
Move Eva closer to Adam
Remove the metal
24 VDC input to pin-2 (no dynamic signal)
Check if there is 24 VDC to input (pin-2). If Yes, check cable or unit before and fix it.
No lights
Lights green (but no dynamic output detected)
Loss of power supply
Defected dynamic signal input to unit
(asymmetric pulses)
Check 24 VDC / 0 VDC power supply
Check the dynamic input or the unit before
Lights green/red (flashing)
Weak lights or red and green lights at the same time
No dynamic input (Eva in position with
Adam), or info-output (pin-5) connected to
0 VDC
Check the unit before (make it active). Check the infooutput, fix it.
The unit is defect
The unit needs to be replaced. Contact ABB Jokab
Safety.
Warning! Replace a defected unit with a new one and never bypass the safety circuit using Tina 1A or any other solution.
2TLJ172066M0201, rev. F
2015-02-09
11 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
5 Operation
LED indication
Operation status LED
LED
LED on Adam
Indication
Green
Green-Red (flash)
Green-Red (flash fast)
Red
Description
Eva close, safety circuit closed
Eva close, safety circuit broken by a previous unit
Eva within ~2 mm of max sensing distance
Eva distant, safety circuit broken
Information output signal attributes
When Eva is in contact with Adam, the information output of the unit (pin-5) is set either high (+24 VDC) or low (0
VDC) depending on four different input signals (pin-2):
Dynamic signal - Dynamic signal input exist, i.e. the safety circuit is OK up until this unit
No dynamic signal - Dynamic signal input does not exist, i.e. the safety circuit is interrupted before this unit.
+24 VDC - A constant +24 VDC signal is applied = high (H)
0 VDC - The pin is connected to 0 VDC = low (L)
The information output signal depends on the input signal according to the table below. Note that if the safety is interrupted, i.e. if Eva is away from Adam, the information output signal is always low (L).
Input signal (pin-2) Dynamic signal No dynamic signal +24 VDC 0 VDC
Info output signal (pin-5) High High Low High
The delay for switching the information signal output from high to low (H
L) and low to high (L
H) is given in the table below.
Info output signal switch H L
Delay ~ 135 ms
L H
~ 2 ms
Warning! The information output signal is not a failsafe signal and should never be used for the safety purpose(s).
2TLJ172066M0201, rev. F
2015-02-09
12 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
6 Model overview
Type
Eva
Eva E
Adam M12
Adam 3 m
Adam E 5 m
Adam 10 m
Adam 20 m
Adam E 10 m
Adam E 0.5 m M12
Adam E 20 m
Article number Description
2TLA020046R0000 Eva
2TLA020046R0600 Eva E, protective housing (IP69K)
2TLA020051R0000 Adam, 5-pole M12 connector, 4x protection plates (DA1)
2TLA020051R0200 Adam, 5-pole cable, 3 m
2TLA020051R0300 Adam E, 5-pole cable, 5 m, protective housing (IP69K)
2TLA020051R0400 Adam, 5-pole cable, 10 m
2TLA020051R0500 Adam, 5-pole cable, 20 m
2TLA020051R0600 Adam E, 5-pole cable, 10 m, protective housing (IP69K)
2TLA020051R0700 Adam E, 5-pole cable with M12 connector, 0.5 m, protective housing (IP69K)
2TLA020051R0800 Adam E, 5-pole cable, 20 m, protective housing (IP69K)
Adam
Integrated cable
Eva * Available cable lengths depending on model
Adam M12
M12 connector
(5-pole, male)
Eden E
Protective housing for extreme surroundings
(IP69K) Cable length:
3 / 10 / 20 m *
Some Eden models are available in grey; refer to your ABB Jokab Safety sales representative for more information.
Accessories
Type Article number
-
-
DA1
DA2
-
2TLA020053R0000
2TLA020053R0100
2TLA020053R4200
2TLA020053R4300
2TLA020053R5000
Description
Protection plate
Mounting spacer
Safety screw SM4 x 20, for mounting Adam and Eva
Safety screw SM4 x 25, for mounting Adam E and Eva E
Safety screwdriver bit SBITS
Protection plate (DA1)
Safety screws and screwdriver bit
2TLJ172066M0201, rev. F
2015-02-09
13 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
7 Technical data
Manufacturer
Address ABB JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Power supply
Operating voltage
Total current consumption
24 VDC +15 %, -25 %
45 mA (55 mA with max information output)
Information output: Max 10 mA t < 60 µs Time delay t (in/out) Eden
General
Protection class
Ambient temperature
Eden
Eden E
Humidity range
Housing material
Connector
Size
Mechanical life
Weight
Colour
Maximum detection distance
(Hysteresis approx 1 mm)
Assured release distance (S ar
)
Assured operating distance (S ao
)
Chemical resistance
Macromelt
(Eden and Eden C)
Polyurethane (PU)
(Eden E and Eden EC)
Eden: IP67
Eden E: IP69K
Storage: 25…+70°C
Operation: 25…+70°C
Storage: -40 …+70°C
Operation: -
25…+70°C
35 to 85 % (with no icing or condensation)
Eden: Based on polyamide, Macromelt OM646 (V0)
Protective housing (Eden E): Polyurethane (PU)
M12 5-pole male (Adam M12, Adam E 0.5 m M12)
5-pole cable 3 m (Adam 3 m)
5-pole cable 10 m (Adam 10 m, Adam E 10 m)
5-pole cable 20 m (Adam 20 m, Adam E 20 m)
Cables (5-pole + screen):
Material: PVC, UL2464
Cable size: ø5.7 mm
Conductor size: 0.34 mm 2
See drawings below
10
7
cycles
Eva: 26 g
Eva E: 36 g
Adam M12: 30 g
Yellow or grey depending on model, black text
Eden: 15 +/- 2 mm
Eden E: 12 +/- 2 mm
Eden: 45 mm
Eden E: 36 mm
Eden: 7.5 mm
Eden E: 6 mm
Cutting oils, vegetable and animal oils, hydrogen peroxide, diluted acids and bases: Good.
Alcohol and strong acids: Not recommended.
Cutting oils, vegetable and animal oils, hydrogen peroxide, diluted acids and bases, alcohol: Good.
Strong oxidation acids: Not recommended.
2TLJ172066M0201, rev. F
2015-02-09
14 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Safety / Harmonized standards
Conformity
IEC/EN 615081…7
EN 62061
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2010, EN 954-1:1996, EN ISO 13849-1:2008, EN 62061:2005,
EN 62061:2005, EN 61508:2010, EN 60204-1:2006+A1:2009, EN 60664-1:2007,
EN 61000-6-2:2005, EN 61000-6-4:2007, EN 60947-5-1:2004, EN 1088+A2:2008
SIL3, PFH d
: 4.50*10 -9
SIL3
EN ISO 13849-1 Performance level: Pl e, category 4
Certificates TÜV Nord
The Jokab Safety branded product with article number beginning with 2TLJ is fully compatible with the ABB branded product with article number beginning with 2TLA.
Intended use
NB! These restrictions are only according to certification for CSA (Canada/USA).
Pollution degree, 2
Installation category N/A
Altitude, 2000 m (max)
Humidity, 80 % max for temperatures up to 31 °C and 35-85 % without condensation
Electrical supply < 2 W, 24 VDC
Indoor use statement
Temperature, -10 to 55 °C.
Dimensions
Eden dimensions
2TLJ172066M0201, rev. F
2015-02-09
15
Eden M12, contact seen from outside. www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
Eden E dimensions
NB: All measurements in millimetres.
2TLJ172066M0201, rev. F
2015-02-09
16 www.abb.com/jokabsafety
Please note!
This model of Eden is obsolete and has been replaced by Eden DYN
8 EC Declaration of conformity
2TLJ172066M0201, rev. F
2015-02-09
ABB JOKAB SAFETY Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety
17 www.abb.com/jokabsafety
advertisement
Related manuals
advertisement
Table of contents
- 2 Read and understand this document
- 4 Introduction
- 4 Scope
- 4 Audience
- 4 Prerequisites
- 4 Special notes
- 5 Overview
- 5 General description
- 5 Safety regulations
- 6 Connections
- 7 Connection examples
- 9 Installation and maintenance
- 10 Installation precautions
- 11 Maintenance
- 11 Testing of the safety functions
- 11 Troubleshooting
- 12 Operation
- 12 LED indication
- 12 Information output signal attributes
- 13 Model overview
- 13 Accessories
- 14 Technical data
- 17 EC Declaration of conformity