Trane Cold Generator Installation, Operation And Maintenance Manual
PDF
Dokument
Reklamë
Reklamë
Installation, Operation, and Maintenance Cold Generator™ Scroll Liquid Chillers Model CGWR and CCAR 20 to 65 Tons (60 Hz) Water-Cooled and Compressor Chillers SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. September 2017 CG-SVX038A-EN Introduction Read this manual thoroughly before operating or servicing this unit. Warnings, Cautions, and Notices Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions. The three types of advisories are defined as follows: a potentially hazardous WARNING Indicates situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous CAUTIONs situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. NOTICE Indicates a situation that could result in equipment or property-damage only accidents. Important Environmental Concerns Scientific research has shown that certain man-made chemicals can affect the earth’s naturally occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs). Not all refrigerants containing these compounds have the same potential impact to the environment. Trane advocates the responsible handling of all refrigerants-including industry replacements for CFCs and HCFCs such as saturated or unsaturated HFCs and HCFCs. Important Responsible Refrigerant Practices Trane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified according to local rules. For the USA, the Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these service procedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them. © 2017 Ingersoll Rand WARNING Proper Field Wiring and Grounding Required! Failure to follow code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. WARNING Personal Protective Equipment (PPE) Required! Failure to wear proper PPE for the job being undertaken could result in death or serious injury. Technicians, in order to protect themselves from potential electrical, mechanical, and chemical hazards, MUST follow precautions in this manual and on the tags, stickers, and labels, as well as the instructions below: • Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing). ALWAYS refer to appropriate Material Safety Data Sheets (MSDS)/Safety Data Sheets (SDS) and OSHA guidelines for proper PPE. • When working with or around hazardous chemicals, ALWAYS refer to the appropriate MSDS/SDS and OSHA/GHS (Global Harmonized System of Classification and Labelling of Chemicals) guidelines for information on allowable personal exposure levels, proper respiratory protection and handling instructions. • If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPE in accordance with OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING, DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR INTENDED VOLTAGE. CG-SVX038A-EN Introduction WARNING Follow EHS Policies! Failure to follow instructions below could result in death or serious injury. • All Ingersoll Rand personnel must follow Ingersoll Rand Environmental, Health and Safety (EHS) policies when performing work such as hot work, electrical, fall protection, lockout/tagout, refrigerant handling, etc. All policies can be found on the BOS site. Where local regulations are more stringent than these policies, those regulations supersede these policies. • Non-Ingersoll Rand personnel should always follow local regulations. WARNING Refrigerant under High Pressure! Failure to follow instructions below could result in an explosion which could result in death or serious injury or equipment damage. System contains oil and refrigerant under high pressure. Recover refrigerant to relieve pressure before opening the system. See unit nameplate for refrigerant type. Do not use nonapproved refrigerants, refrigerant substitutes, or refrigerant additives. Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. Trademarks All trademarks referenced in this document are the trademarks of their respective owners. CG-SVX038A-EN 3 Table of Contents Model Number Descriptions . . . . . . . . . . . . . . 5 Unit Components . . . . . . . . . . . . . . . . . . . . . . . . 6 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Inspection Check List and Unit Identification 9 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Dimensions and Weights . . . . . . . . . . . . . . . . 11 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Unit Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . 27 Unit Controller—Software Installation and Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Unit Startup Procedures . . . . . . . . . . . . . . . . . 33 Unit Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . 35 Unit Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Electrical Schematics . . . . . . . . . . . . . . . . . . . 40 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 4 CG-SVX038A-EN Model Number Descriptions Digit 1, 2, 3, 4 — Unit Type CGWR=Water-Cooled Chiller CCAR= Compressor Chiller Digit 5, 6, 7 — Unit Nominal Tonnage 020 = 030 = 040 = 050 = 065 = 20 Nominal Tons 30 Nominal Tons 40 Nominal Tons 50 Nominal Tons 65 Nominal Tons Digit 8 — Unit Voltage A B F G = = = = 208V/60/3 230V/60/3 460V/60/3 575V/60/3 Digit 9, 10 — Design Sequence A0 = Factory Assigned Digit 11 — Agency Listing N E = = None ETL/ETL-C Listed to meet U.S. and Canadian Safety Standards Digit 12 — Condenser Water Regulating Valve 0 1 = = None With Digit 13 — Evaporator Wye Strainer 0 = None 1 2 = = Nominal Flow Wye Strainer Nominal Flow Wye Strainer with installation kit1 Digit 14 — Evaporator Temp Range 0 = 1 = Standard Cooling 42 to 60°F [4.4 to 5.5°C] Standard Cooling/Ice Making 20 to 60°F [-6.7 to 15.6°C] Digit 16 — Short Circuit Rating (SCCR) 0 1 = = Standard 5 kA Rating Optional 100 kA Rating Digit 17 — Sound Attenuator 0 3 9 = = = No Sound Attenuation Compressor Sound Blanket(s) Factory Sound Enclosure Cabinet(s) Digit 18 — Local Unit Controller Interface 0 1 = = Keypad with Dot Pixel Display Color Touchscreen Digit 19 — Remote BMS Interface (Digital Comm) 0 2 4 5 6 8 = = = = = = None LonTalk® BACnet® Ms/TP BACnet IP MODBUS® Johnson N2 Digit 20 — Power Monitor 0 1 = = None With Digit 21 — Neoprene Isolator Pads 0 1 = = None With Digit 22 — Flow Switch 0 1 = = None With Digit 23 — Evaporator Fluid Type 0 2 3 4 = = = = Water Ethylene Glycol Propylene Glycol Methanol Digit 15 — Power Connection Digit 24 — Condenser Fluid Type T D F 0 2 3 4 9 = = = Terminal Block Non-Fused Disconnect Switch Fused Disconnect Switch = = = = = Water Ethylene Glycol Propylene Glycol Methanol Not Applicable — Compressor-Chiller Digit 25 — Special Options 0 1 1 = = None With Nominal flow wye strainer installation kit includes pipe adaptors, differential pressure ports and blowdown valve. CG-SVX038A-EN 5 Unit Components Power Wiring Location Unit Nameplate (inside door) Optional Disconnect Switch Location Optional 15.4” Color Touchscreen (Keypad w/ Display comes standard) Evaporator Water Inlet (Vic) Evaporator Water Outlet (Vic) Condenser Water Outlet (FPT) Rigging Bracket Install Pockets Condenser Water Inlet (FPT) Removable Water Plate on Shell-andTube Condenser Forklift Pockets Suction Line (1 per circuit) TXV (1 per circuit) Compressor Nameplate Charging Port (1 per circuit) Sight Glass (1 per circuit) Relief Valve (1 per circuit) Solenoid Valve (1 per circuit) Filter Drier (1 per circuit) Liquid Line (1 per circuit) Hot Gas Injection Solenoid Valve (1 per circuit) 6 CG-SVX038A-EN General Data Table 1. General data for CGWR water-cooled chillers Unit Size 20 30 40 50 65 Compressor Quantity each 2 2 3 3 3 Nominal Tons tons 10/10 15/15 10/10, 20 12/12, 25 15/15, 30 Steps of Unloading % 100-50 100-50 100-75-50-25 100-75-50-25 100-75-50-25 Compressor Sound Data(a) dBA 81.0 84.0 87.2 87.5 90.2 Compressor Sound Data with Sound Blankets Only(a) dBA 75.0 78.0 82.8 83.0 85.8 Evaporator Water Storage gal 2.1 3.0 3.1 3.7 4.6 Minimum Flow gpm 30 45 66 82 104 Maximum Flow gpm 104 151 207 237 295 9.2 Condenser (each) Water Storage (each) gal 3.0 4.5 5.5 7.4 Minimum Flow (each) gpm 28 39 49 64 84 Maximum Flow (each) gpm 119 167 207 271 342 R-410A R-410A R-410A R-410A R-410A 1 1 2 2 2 General Unit Refrigerant Number of Independent Refrigerant Circuits Refrigerant Charge per Circuit (approx.) lb Oil Type Oil Charge (each compressor) oz 25 37 24, 24 26, 26 31, 31 POE 160SZ POE 160SZ POE 160SZ POE 160SZ POE 160SZ 112/112 113/113 112/112, 227 112/112, 227 112/112, 227 Notes: 1. Data containing information on two circuits formatted as follows: Circuit 1, Circuit 2 2. Nominal compressor sizes based on 60 Hz. (a) Compressor manufacturer sound power reported at rated compressor AHRI conditions measured in free space for individual compressors. Table 2. General data for CCAR compressor chillers Unit Size 20 30 40 50 65 Compressor Quantity each 2 2 3 3 3 Nominal Tons tons 10/10 15/15 10/10, 20 12/12, 25 15/15, 30 Steps of Unloading % 100-50 100-50 100-75-50-25 100-75-50-25 100-75-50-25 Compressor Sound Data(a) dBA 81.0 84.0 87.2 87.5 90.2 Compressor Sound Data with Sound Blankets Only dBA 75.0 78.0 82.8 83.0 85.8 Evaporator Water Storage gal 2.1 3.0 3.1 3.7 4.6 Minimum Flow gpm 30 45 66 82 104 Maximum Flow gpm 104 151 207 237 295 R-410A R-410A R-410A R-410A R-410A 1 1 2 2 2 General Unit Refrigerant Number of Independent Refrigerant Circuits Refrigerant Charge per Circuit (approx.) lb Oil Type Oil Charge (each compressor) oz 16 19 12,12 13,13 16,16 POE 160SZ POE 160SZ POE 160SZ POE 160SZ POE 160SZ 112/112 113/113 112/112, 227 112/112, 227 112/112, 227 Notes: 1. Data containing information on two circuits formatted as follows: Circuit 1, Circuit 2 2. Nominal compressor sizes based on 60 Hz. (a) Compressor manufacturer sound power reported at rated compressor AHRI conditions measured in free space for individual compressors. CG-SVX038A-EN 7 General Data Ambient Limits — CCAR/CAUJ Combination Minimum Ambient Temperature Limit Refer to SS-APG014*-EN Application Guide – Pairing Trane CCAR Compressor Chillers (20 to 65 tons) with Trane CAUJ Air-Cooled Condensers (20 to 80 tons). In general, the minimum outdoor ambient temperature for operation of CCAR compressor chiller in combination with a CAUJ air cooled condenser is 40°F. In some cases, with factory application approval, the CCAR/CAUJ combination can be operated down to the 20°F ambient. This minimum is primarily driven by compressor chiller starting considerations and not by effectiveness of condenser ambient controls once the system is up and running. Fan cycling and optimal low ambient dampers do not mitigate the low ambient starting challenge. On a cold day with outdoor ambient temperature below 40°F, the liquid line pressure at the expansion valve inlet, in most circumstances, is extremely low. On start, the suction pressure tends to plunge into the freezing range potentially causing a nuisance fault. Contact the factory to request application approval for applications where CCAR/CAUJ combination is intended for operation with ambient temperature below 40°F. Maximum Ambient Temperature Limit The maximum ambient temperature limit for the CCAR/ CAUJ operation is 110°F. 8 CG-SVX038A-EN Inspection Check List and Unit Identification To protect against loss due to damage incurred in transit, complete the following checklist upon receipt of the unit. • Inspect the individual pieces of the shipment before accepting the unit. Check for obvious damage to the unit or packing material. • Inspect the unit for concealed damage as soon as possible after delivery and before it is stored. Concealed damage must be reported within 15 days. • If concealed damage is discovered, stop unpacking the shipment. Do not remove damaged material from the receiving location. Take photos of the damage, if possible. The owner must provide reasonable evidence that the damage did not occur after delivery. • Notify the carrier’s terminal of the damage immediately, by phone and by mail. Request an immediate, joint inspection of the damage with the carrier and the consignee. • Notify the Trane sales representative and arrange for repair. Do not repair the unit, however, until damage is inspected by the carrier’s representative. Each unit is completely assembled with refrigerant piping, power and control wiring, and top coated with two-part epoxy. Refrigeration circuits are leak-tested and dehydrated prior to introduction of refrigerant. CGWR and CCAR units are then fully charged with compressor oil and refrigerant, and run tested prior to shipment. • CGWR units are shipped with full operating charge of compressor oil and refrigerant. • CCAR units are shipped with a nominal charge of compressor oil and a holding charge of dry nitrogen. CCAR units are to be field piped to condenser, dehydrated and charged with refrigerant by others. Note that compressor oil charge may have to be adjusted. See SS-APG014*-EN, Application Guide, Pairing Trane CCAR Compressor Chillers with Trane CAUJ Air-Cooled Condensers for application guidelines. After completing the inspection checklist, identify the unit with the unit nameplate, packing list and ordering information. The unit nameplate is mounted inside the control box. Refer to “Model Number Descriptions,” p. 5 for additional data that can be found on the nameplate. Check all items against the shipping list. Verify that it is the correct unit and that it is properly equipped. If optional neoprene or spring isolators (or other ship-loose items) are ordered, they are secured in place on the shipping skid or inside the unit control box. The Installation, Operation, and Maintenance manual can also be found in the unit control box. Be sure to read all of this literature before installing and operating the unit. Unit Description Trane CGWR water-cooled chillers and CCAR compressor chillers (condenserless chillers) are designed for installation on a prepared surface in a suitable, weatherproof location above freezing (32°F). • CGWR/CCAR 20 and 30 ton chiller units have one refrigerant circuit fitted with a manifolded scroll compressor set piped in parallel. • CGWR/CCAR 40, 50 and 65 ton chiller units have two refrigerant circuits. One refrigerant circuit is fitted with a manifolded scroll compressor set piped in parallel, and the other refrigerant circuit has a single scroll compressor. Units also have brazed plate evaporator, shell-and-tube condenser (CGWR only) and control box with integral control panel, all mounted on a common frame. CG-SVX038A-EN 9 Electrical Data Table 3. Electrical data — CGWR water cooled chillers & CCAR compressor chillers Unit Wiring Data Unit Size 20 30 40 50 65 Compressors Minimum Circuit Ampacity Maximum Fuse Size Recommended Dual Element Fuse Size 200-230/3/60 88 125 100 460/3/60 42 60 50 575/3/60 35 50 200-230/3/60 108 460/3/60 575/3/60 RLA (ea) LRA (ea) Control KW 39/39 267/267 98 19/19 142/142 98 40 15/15 103/103 98 150 125 48/48 351/351 98 56 80 60 25/25 197/197 98 50 70 60 22/22 135/135 98 200-230/3/60 162 225 175 39/39, 67 267/267, 485 159 460/3/60 78 110 90 19/19, 33 142/142, 215 159 Rated Voltage Refrig. Qty Circuits 2 2 3 1 1 2 Nom. Tons 10/10 15/15 10/10, 20 575/3/60 64 80 70 15/15, 26 103/103, 175 159 200-230/3/60 185 250 225 41/41, 82 304/304, 560 159 460/3/60 88 125 100 19/19, 40 147/147, 260 159 575/3/60 69 90 80 17/17, 29 122/122, 210 159 200-230/3/60 232 300 250 48/48, 109 351/351, 717 159 460/3/60 113 150 125 25/25, 51 197/197, 320 159 575/3/60 93 125 110 22/22, 38 135/135, 235 159 3 3 2 2 12/12, 25 15/15, 30 Notes: 1. Data containing information on two circuits formatted as follows: Circuit 1, Circuit 2 2. Add 31 VA to control power for optional water regulating valve (WRV) 3. Use copper conductors only. 4. Local codes may take precedence. 5. Voltage Utilization Range: Rated Voltage 208-230/3/60 460/3/60 380/3/60 575/3/60 10 Utilization Range 187-253 414-506 342-418 518-632 CG-SVX038A-EN Dimensions and Weights Dimensions Refer to name plate on control box door (inside) for specific unit electrical data. The Trane application manual and/or project submittals contain dimensional data, application data, and electrical data as required. These documents can be forwarded for specific jobs as part of a job submittal package upon request. Figure 1. CGWR/CCAR 20 to 30 ton mechanical drawing J 10 9 15 13 K H 14 L I G F T (4 PLACES) D E A 12 1 5 8 M 6 2 B* N* B N 4 R* 16 7 R W 11 U 3 V C S CG-SVX038A-EN 11 Dimensions and Weights Table 4. CGWR/CCAR 20 to 30 ton — in (mm) Dimension CGWR 20 CGWR30 CCAR 20 CCAR30 A(a) 76.6 (1946) 77.5 (1969) 70.4 (1788) 70.4 (1788) 45.8 (1163)* B 59.8 (1519) 59.8 (1519) 45.8 (1163)* C 19.3 (490) 20.1 (511) N/A N/A D 26.7 (678) 26.7 (678) 26.7 (678) 26.7 (678) E 28.9 (734) 28.9 (734) 28.9 (734) 28.9 (734) F 37.0 (940) 37.0 (940) 37.0 (940) 37.0 (940) G 17.0 (432) 17.0 (432) 17.0 (432) 17.0 (432) H 20 (508) 20 (508) N/A N/A I 36 (914) 36 (914) 36 (914) 36 (914) J(b) 36 (914) 36 (914) 36 (914) 36 (914) K(b) 36 (914) 36 (914) 36 (914) 36 (914) L 24 (610) 24 (610) 24 (610) 24 (610) M 36 (914) 36 (914) 36 (914) 36 (914) N 53.5 (1359) 53.5 (1359) 39.5 (1003)* 39.5 (1003)* R 33.1 (841) 33.1 (841) 19.1 (485)* 19.1 (485)* S 13.4 (240) 13.4 (240) N/A N/A T 0.6 (15) 0.6 (15) 0.6 (15) 0.6 (15) U 10.2 (259) 10.2 (259) 10.2 (259) 10.2 (259) V 10.3 (262) 10.4 (264) N/A N/A W 13.9 (353) 15.3 (389) N/A N/A 1 2 (51) VIC 2.5 (64) VIC 2 (51) VIC 2.5 (64) VIC 2 2 (51) VIC 2.5 (64) VIC 2 (51) VIC 2.5 (64) VIC 3 2 (51) FPT 2.5 (64) FPT N/A N/A 4 2 (51) FPT 2.5 (64) FPT N/A N/A Reference 1 Evaporator Water Inlet 9 Condenser Return Waterbox End (CGWR only)- minimum clearance (for maintenance) 2 Evaporator Water Outlet 10 Condenser Inlet/Outlet End (CGWR only) minimum clearance (for maintenance) 3 Condenser Water Inlet (CGWR only) 11 Condenser (CGWR only) 4 Condenser Water Outlet (CGWR only) 12 Evaporator 5 Power Disconnect (Optional) 13 Panel Power Section — door swing 24 in (610 mm) 6 Power Wire Entry 14 Panel Control Section — door swing 24 in (610 mm) 7 Control Wire Entry 15 Additional minimum clearance needed for units with water regulating valve option 8 Control Panel 16 Location of CCAR refrigerant line connections, 7/8 in liquid line and 1-3/8 in discharge lines (a) For CGWR020 and 030: If water regulating valve option is ordered, the overall length is 90.9 in and 93.1 in, respectively. (b) Exceptions: 1. A minimum clearance of 42 in (1067mm) is required to other electrically grounded parts. 2. A minimum clearance of 48 in (1220mm) is required between two units opposite each other (front-to-front or back-to-back) or to other electrically live parts. See Section 110.26 of National Electrical code (NEC). 12 CG-SVX038A-EN Dimensions and Weights Figure 2. CGWR/CCAR 40 to 65 ton mechanical drawing J 15 9 10 13 K H 14 L I G T (4 PLACES) F D E A 12 5 8 6 M 1 7 2 B* N* 4 N B R* 16 R W V 11 U S CG-SVX038A-EN 3 C 13 Dimensions and Weights Table 5. CGWR/CCAR 40 to 65 ton — in (mm) Dimension CGWR40 CGWR50 CGWR65 CCAR40 CCAR50 CCAR65 A(a) 83.8 (2128) 83.8 (2128) 83.8 (2128) 87.6 (2225) 87.6 (2225) 87.6 (2225) 45.8 (1163)* B 59.8 (1519) 59.8 (1519) 59.8 (1519) 45.8 (1163)* 45.8 (1163)* C 13.1 (333) 13.6 (345) 13.6 (345) N/A N/A N/A D 26.7 (678) 26.7 (678) 26.7 (678) 26.7 (678) 26.7 (678) 26.7 (678) E 29.6 (752) 29.9 (759) 29.9 (759) 29.0 (737) 29.0 (737) 29.0 (737) F 51.0 (1295) 51.0 (1295) 51.0 (1295) 51.0 (1295) 51.0 (1295) 51.0 (1295) G 19.2 (488) 19.2 (488) 19.2 (488) 19.2 (488) 19.2 (488) 19.2 (488) H 20 (508) 20 (508) 20 (508) N/A N/A N/A I 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) J(b) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) K(b) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 24 (610) L 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) M 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) N 49.6 (1260) 49.6 (1260) 49.6 (1260) 35.6 (904)* 35.6 (904)* 35.6 (904)* R 34.0 (864) 34.0 (864) 34.0 (864) 20.0 (508)* 20.0 (508)* 20.0 (508)* S 13.4 (340) 13.4 (340) 13.4 (340) N/A N/A N/A T 0.6 (15) 0.6 (15) 0.6 (15) 0.6 (15) 0.6 (15) 0.6 (15) U 12.2 (310) 12.2 (310) 12.2 (310) 12.2 (310) 12.2 (310) 12.2 (310) V 10.6 (269) 11.0 (279) 11.0 (279) N/A N/A N/A W 15.5 (394) 16.8 (427) 16.8 (427) N/A N/A N/A 1 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 2 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3.0 (76) VIC 3 2.5 (64) FPT 3.0 (76) FPT 4.0 (102) FPT N/A N/A N/A 4 2.5 (64) FPT 3.0 (76) FPT 4.0 (102) FPT N/A N/A N/A Reference 1 Evaporator Water Inlet 9 Condenser Opposite Inlet/Outlet End (CGWR only) — minimum clearance (for maintenance) 2 Evaporator Water Outlet 10 Condenser Inlet/Outlet End (CGWR only) — minimum clearance (for maintenance) 3 Condenser Water Inlet (CGWR only) 11 Condenser (CGWR only) 4 Condenser Water Outlet (CGWR only) 12 Evaporator 5 Power Disconnect (Optional) 13 Panel Power Section — door swing 31.3 in (795 mm) 6 Power Wire Entry 14 Panel Control Section — door swing 31.3 in (795 mm) 7 Control Wire Entry 15 Additional minimum clearance needed for units with water regulating valve option 8 Control Panel 16 Location of CCAR refrigerant line connections, (2) 1-1/8 in liquid line and (2) 1-3/8 in discharge lines (a) For CGWR040, 050 and 065: If water regulating valve option is ordered, the overall length is 93.8 in, 95.0 in, and 96.2 in respectively. (b) Exceptions: 1. A minimum clearance of 42 in (1067mm) is required to other electrically grounded parts. 2. A minimum clearance of 48 in (1220mm) is required between two units opposite each other (front-to-front or back-to-back), or to other electrically live parts. See Section 110.26 of National Electrical code (NEC). 14 CG-SVX038A-EN Dimensions and Weights Weights Table 6. Weights Shipping Unit CGWR CCAR CG-SVX038A-EN Operating Size lbs kg lbs kg 20 1116 506 1042 473 30 1252 568 1242 563 40 1659 753 1577 715 50 1847 838 1833 831 65 2039 925 2005 909 20 846 384 732 332 30 909 412 809 367 40 1265 574 1110 503 50 1304 591 1152 523 65 1484 673 1336 606 15 Installation General Installation Information • Where specified, supply and install valves in the water piping upstream and downstream of the evaporator and condenser, to isolate the heat exchangers for maintenance and to balance/trim the system. • Supply and install condenser water control valve. Refer also to Trane publication RLC-PRB021-EN available from Trane Sales Offices for additional technical assistance. Provisions must be made for the control of condenser water that results in stable Saturated Discharge Pressure between 80°F and 128°F through all steady state, part load and transient operating conditions. Trane recommends optional factory installed integral Water Regulating Valve operated by onboard controller. • Optional Water Regulating Valve — Trane offers a fully installed and integrated water regulating valve designed to stabilize discharge pressure at all full and part load conditions. Factory installed water regulating valve is controlled by the chiller’s unit controller and is available on all models. • Supply and install an approved flow switch, or suitable flow proving device, in the chilled water line as shown in Figure 3, p. 21. Flow switch must be interlocked with chiller’s unit controller to ensure the unit cannot operate when chilled water flow through the unit is below the minimum chilled water flow limit. See fieldwiring diagram for flow proving device connection points. A factory approved flow switch may be ordered with the unit as a shipped-loose option, for field installation by others. • • Supply and install drain vent points with valves on both chilled and condenser water line to vent air and drain lines and equipment for service. Install a wye strainer ahead of all system pumps and control valves. Note: A wye strainer with twenty mesh screen must be installed in the chilled water pipe immediately adjacent to the evaporator inlet. See Figure 3, p. 21. A factory approved wye strainer may be ordered with the unit as a shipped-loose option, for field installation by others. • Supply and install suitable refrigerant pressure relief piping from the pressure relief to the atmosphere if required. Follow ANSI/ASHRAE 15-2007 guidelines, relief manufacturer’s guidelines, and industry standards when working with relief piping. • If necessary, supply enough refrigerant and dry nitrogen (150 psig) for pressure testing (CCAR). • Start the unit under supervision of a qualified service technician. • Where specified, supply and insulate the chilled water piping as required, to prevent sweating under normal 16 operating conditions. Trane provides factory insulation on evaporator and related components. Storage NOTICE: Store Units Above Freezing! Store these units in a protected area above freezing (32°F) only. Do not store outdoors with a protective covering such as a plastic shroud. This can result in excessive water condensation that could damage controls and other components. These units are designed for indoor installation above freezing (32°F) only. Store the unit in a suitable weatherproof location above 32°F, vibration free, and secure area. Periodically check the pressure in each refrigerant circuit to verify that the refrigerant charge is intact. If it is not, contact a qualified service organization and the appropriate sales office. If the unit is still under factory warranty, you must follow warranty procedure prior to calling for service. Noise Considerations Locate the unit away from sound-sensitive areas. If necessary, install the optional isolators under the unit and/ or the optional factory sound attenuation compressor blankets or attenuation cabinet. Install vibration isolators in all piping and use flexible electrical conduit. Consult an acoustical engineer for critical applications. Foundation A base or foundation is recommended for most installations. Provide a level surface strong enough to support the unit. Refer to “Dimensions and Weights,” p. 11 for dimensions and weights. A flexible (isolated) concrete foundation or footings at each loading point will reduce transmission of vibration. Install anchor bolts in the concrete to secure the unit. If the floor is warped, uneven or in poor condition, make necessary repairs before positioning the unit. Once the unit is in place, it should be level, within 1/4 inch over its entire length and width. Clearances Provide enough space around the unit to allow the installation and maintenance personnel unrestricted access to all service points. Unit dimensions are given in “Dimensions and Weights,” p. 11. There should be adequate clearance for condenser and compressor servicing. A minimum of three feet is recommended for effective compressor service. A minimum clearance of 3 ft.-6 inches is required to open the control panel doors. CG-SVX038A-EN Installation A minimum clearance of 42 in (2067 mm) is required to other electrically grounded parts. A minimum clearance of 48 in (1220 mm) is required between two units opposite each other (front-to-front or back-to-back) or to other electrically live parts. See Section 110.26 of National Electrical Code (NEC). Important: In all cases, local codes will take precedence over these recommendations. Rigging/Lifting Procedure If the CGWR/CCAR is not moved using a forklift and the forklift pockets provided as part of the chiller's frame, then the chiller should be lifted and moved by using the lifting rails as outlined in Step 1 through Step 8. A set of lifting rails is shipped loose and attached to the unit skid. Install the lifting rails and lift as shown below: Ventilation Provisions must be made to remove heat generated by unit operation from the equipment room. Ventilation must be adequate to maintain an ambient temperature lower than 125°F. The condenser relief valve on these units must be vented in accordance with all local and national codes. Drainage Locate the unit near a large capacity drain for condenser drain-down during shutdown or repair. Handling BACK VIEW WARNING Heavy Objects! Failure to follow instructions below or properly lift unit could result in unit dropping and possibly crushing operator/technician which could result in death or serious injury, and equipment or property-only damage. Ensure that all the lifting equipment used is properly rated for the weight of the unit being lifted. Each of the cables (chains or slings), hooks, and shackles used to lift the unit must be capable of supporting the entire weight of the unit. Lifting cables (chains or slings) may not be of the same length. Adjust as necessary for even unit lift. CCAR and CGWR units are shipped stretch-wrapped and bolted to a shipping skid (unless other than standard shipping is selected). The skidded unit can be moved by using a fork truck of suitable capacity. Refer to “Dimensions and Weights,” p. 11 for unit weights. When moving the unit, the lifting forks must be positioned under the shipping skid as wide as possible where labeled. Lift the unit and move it to the desired location. Once the unit is at the installation location, remove the stretch wrap. Inspect the unit for damage and report if damage is found. The optional unit isolators (if ordered) are secured to the shipping skid or in the unit control panel. Other optional “ship loose” items may be attached to the skid or shipped separately depending on options selected. CG-SVX038A-EN 40" LEFT END VIEW WARNING Heavy Objects! Failure to follow instructions below or properly lift unit could result in unit dropping and possibly crushing operator/technician which could result in death or serious injury, and equipment or property-only damage. Ensure that all the lifting equipment used is properly rated for the weight of the unit being lifted. Each of the cables (chains or slings), hooks, and shackles used to lift the unit must be capable of supporting the entire weight of the unit. Lifting cables (chains or slings) may not be of the same length. Adjust as necessary for even unit lift. 17 Installation 1. Remove the stretch wrap from the unit as described In the Handling section, leaving the unit mounted to the skid. The lifting rails should be mounted to the skid. Remove the rails from the skid. 2. The hardware used to secure the lifting rails to the unit frame can be found in a box in the unit control panel. Insert the lifting rails as shown in the above figure. Using the mounting hardware, secure the lifting rails to the unit frame by torquing the 1/2” bolts to 70 ft-lbs. 3. Install clevis connectors or equivalent in the 1-1/4 inch lifting holes provided at each end of the lifting rails. 4. Attach certified lifting chains (cables) to these points. Each chain (cable) alone must be strong enough to lift the unit. 5. Attach chains (or cables) to a lifting beam. Position the chains (cables) so that they do not contact the unit piping or the unit control panel. Use a suitable spreader bar to insure proper weight distribution. NOTICE: Equipment Damage! To prevent damage to the unit, position the lifting beam and chains (cables) so that they do not contact the unit piping or the unit control panel. 6. Remove the bolts that secure the unit to the shipping skid. 7. Raise the unit just off the skid to make sure that the unit is level when lifted. Adjust chain (cable) lengths as required for level lifting. 8. Lift the unit off of the skid and place in the installation location. Access Restrictions All CCAR/CGWR units are designed to pass through a standard 36-inch doorway. Refer to outline drawings for other important dimensions. Direct Mounting The unit can be installed directly on an isolated, rigid mounting surface as long as the surface is level and will support the weight of the unit. A mounting hole is provided at each of the unit mounting locations. Provide a means of securely anchoring the unit to the mounting surface. Level the unit carefully. Neoprene Isolator Pad Mounting (Optional) The optional neoprene isolator pads are to be placed between the direct mounting surface and each of the chiller's mounting locations. To help distribute the chiller's load to the neoprene pads, place the 6" x 6" mounting plates between each pad and the chiller. Provide a means of securely anchoring the chiller to the mounting surface. Level the unit carefully as instructed in “Unit Leveling,” p. 18. Compressor Mounting All compressors are rigidly bolted with compressor isolation mounts to compressor mounting rails (tandem compressor sets) or directly to the unit base. No additional isolation or leveling is required. Inspect prior to start up to insure bolts are present and tight, and that no shipping damage has occurred. Unit Leveling Before tightening the mounting bolts, level the unit frontto-back and end-to-end. Unit must be level within 1/4” from front-to-back and within 1/4” over the length of the unit. The unit’s base deck can be used for leveling. Use shims as required to properly level unit base. Compressor Nameplate Trane does not recommend disassembling a CGWR/CCAR to gain access through challenging rigging paths and installation locations. If disassembly/reassembly of a chiller does take place, please note the following: The nameplate for the hermetic scroll compressor is mounted on the compressor housing, near the motor terminal junction box. 1. A qualified Trane technician must perform the task Evaporator Nameplate 2. Use technical support for any questions that may arise during the task 3. Be aware that disassembly/reassembly could possibly affect warranty status of the chiller, especially if failure/ issues occur that point toward improper reassembly & installation 4. All required installation and startup checklists are still required to be completed and promptly returned for review, including the required running data log as instructed in the startup checklist 18 The evaporator nameplate is mounted on evaporator under the insulation. To view the evaporator nameplate, remove the insulation over the area if covered and spread the insulation. The serial number information is also on record at the factory. Condenser Nameplate The condenser ASME nameplate is mounted on the side of the condenser. CG-SVX038A-EN Unit Piping Water Piping — General Make water piping connections to the evaporator and condenser (CGWR only). Isolate and support piping to prevent stress on the unit. Use unions, flanges or grooved lock type fittings to simplify disassembly and facilitate service procedures. Use vibration eliminators to prevent transmitting vibrations to the water lines. Install thermometers in the lines to monitor evaporator and condenser water temperatures. Install balancing cocks in both the leaving chilled water and condenser water lines. These valves can be used to establish a balanced water flow. Entering and leaving chilled and condenser water lines should have shutoff valves installed to isolate the heat exchanger for service. See Figure 3, p. 21 for chilled water piping schematic and Figure 4, p. 22 for condenser water piping schematic. Do not overtighten connections. Use a pipe sealant such as Teflon® tape on all threaded water connections. Flush all piping before attaching to the unit. Unit MUST be bypassed if using a flushing agent. NOTICE: Equipment Damage! To prevent equipment damage, you MUST follow instructions below: • Bypass unit if using a flushing agent. • Chilled water piping must rise above the chiller to insure the evaporator is full of water and void of air at all times. • Do not overtighten connections. Piping and specialties must be installed in accordance with national and local codes. Water Flow Rates Establish balanced water flow through both the evaporator and condenser. Flow rates should fall between the minimum and maximum values given in General Data Table 1 and Table 2, p. 7. Flow rates above or below these values can cause equipment damage or improper unit operation. Measure the evaporator and condenser water pressure drop at the gauge ports located adjacent to the heat exchanger, before any piping specialty components, such as wye strainer. Evaporator water pressure drop curves are shown in Table 5, p. 23. Condenser pressure drop curves are shown in Table 6, p. 23. Optional inlet wye strainer has an outlet port that can be used for measuring inlet evaporator water pressure, if it is installed immediately adjacent to the evaporator inlet. Note: Evaporator and condenser pressure drop measurement is for an approximation and is to be used as a tool to estimate flow rate and as an aid in CG-SVX038A-EN waterside system design. If an accurate measurement of flow rate is required, an accurate flow measurement device must be installed in the water line. Water Treatment NOTICE: Proper Water Treatment Required The use of untreated or improperly treated water in this unit could result in scaling, erosion, corrosion, algae or slime. It is recommended that the services of a qualified water treatment specialist be engaged to determine what water treatment, if any, is required. Trane assumes no responsibility for equipment failures which result from untreated or improperly treated water, or saline or brackish water. Using untreated or improperly treated water in these units may result in inefficient operation and possible tube and/ or brazed plate damage. Consult a qualified water treatment specialist to determine if treatment is needed. NOTICE: Waterborne Debris! To prevent evaporator or condenser damage, evaporator and condenser strainers must be installed in the water supplies to protect components from water born debris. Removal of wye strainer or screen will void the warranty on the brazed plate evaporator. Chilled Water Piping Chilled water piping and associated components shall be installed in accordance with Figure 3, p. 21. Chilled water inlet and outlet types, sizes and locations are provided in Table 4, p. 12 and Table 5, p. 14. Chilled water piping must rise above the chiller to ensure the evaporator is full of water and void of air at all times. All chilled water lines must be insulated to minimize heat gain and prevent condensation. Brazed Plate Evaporator Trane CGWR/CCAR chillers are equipped with brazed plate evaporators made of stamped stainless steel plates, furnace brazed together with copper to form a durable high efficiency heat exchanger. Because of the small complex geometry of the flow passages, it is imperative customers take all precautions to ensure these evaporators are not fouled by large particles or internal mineral deposits. For this reason, a 20 mesh wye strainer is required in the inlet chilled water line. Operation of the chiller without this wye strainer or the wye strainer 20 mesh screen will void the chiller warranty. Chemical 19 Unit Piping treatment of the chilled water loop is required and must be performed by a qualified water specialist. unacceptable system control problems and the potential for evaporator failure. Table 7. NOTICE: Proper Water Treatment! The use of untreated or improperly treated water could result in scaling, erosion, corrosion, algae or slime. It is recommended that the services of a qualified water treatment specialist be engaged to determine what water treatment, if any, is required. Trane assumes no responsibility for equipment failures which result from untreated or improperly treated water, or saline or brackish water. Wye Strainer — Required A wye strainer with 20 mesh screen must be installed immediately adjacent to the inlet water connection to the evaporator. Important: Operation of the chiller without this wye strainer AND 20 mesh screen in place will void the unit warranty. Minimum system volumes CGWR/CCAR Unit Size (tons) Minimum System Volume (gal) 20 157 30 226 40 311 50 355 65 442 Condenser Water Piping Condenser water piping and associated components shall be installed in accordance with condenser water piping schematic Figure 4, p. 22. Condenser water inlet and outlet types, sizes and locations are provided in Table 4, p. 12 and Table 5, p. 14. NOTICE: Excessive Water Pressure! Flow Proving Device — Required To prevent condenser or regulating valve damage, do not exceed nameplate condenser water pressure. NOTICE: Unexpected Chiller Start! Discharge Pressure Control/ Optional Factory-Installed Water Regulating Valve Failure to follow instructions could cause the chiller to start unexpectedly which could result in equipment or property damage. An external source (EMS, time clock or any other means) should not be allowed to bring on a pump that would trigger the flow switch to start the chiller. The flow switch is meant to act as a safety switch and not a start/stop mechanism. Optional chilled water flow switch or other factory approved flow proving device is mandatory. It is fieldinstalled by others. Flow switch is to be installed and maintained in accordance with manufacturer’s recommendations and interconnected to the unit control panel as described in the field-wiring diagram. To provide additional chiller protection, wire the flow proving device control circuit in series with a chilled water pump starter normally open auxiliary contact to create a chilled water pump interlock. See “Chilled Water Flow Switch,” p. 28. Chilled Water System Volume Trane requires minimum system volumes as indicated in Table 7. Special applications may allow deviation from these volumes, but only with approval of Trane engineering. Operation below these volumes will cause 20 A means of maintaining stable discharge pressure during full-load, part-load and transient conditions is required. Saturated discharge temperature must be maintained between 80°F and 128°F. Trane offers an optional factory installed water regulating valve that is controlled by the unit controller. The optional water regulating valve maintains condensing pressure and temperature by throttling water flow leaving the condenser in response to compressor discharge pressure. Field-supplied water regulating valves must be adjusted for proper operation during full-load, part-load and transient conditions. Fieldsupplied water regulating valves must also be adjusted for proper positioning when unit is off. Alternative field-supplied methods for condensing pressure/temperature control include the use of cooling tower control strategies. Cooling tower systems may include a manual or automatic bypass valve that can alter water flow rate and basin temperature to maintain stable condensing temperature at the chiller. Well or city water condensing systems should include a water regulating valve and potentially a pressure reducing valve. A pressure reducing valve should be installed to reduce water pressure entering the condenser if water pressure can exceed tube-side maximum allowable working pressure as indicated on the condenser nameplate. This is also necessary to prevent damage to CG-SVX038A-EN Unit Piping disc and seat type water regulating valves caused by excessive pressure drops through the valve. Under full load AHRI standard conditions, and with approximately 3 gpm/ton cooling water flow through the condenser, the temperature rise across the condenser will be approximately 10°F. In all cases, the minimum inlet condenser water temperature is 65°F. Figure 3. Chilled water piping schematic 8 6 4 T2 7 5 FT 3 2 T4 1 Pi B A 6 T1 T3 5 3 UNIT 2 T5 CUSTOMER PIPING (c) Chilled water flow-proving device is required. Table 8. Reference numbers Item Description 1 Bypass Valve 2 Isolation Valves 3 Vibration Eliminators 4 Evaporator Heat Exchangers 5 Inlet and Outlet Chilled Water Lines 6 Valves for Pressure Measurement 7(a) Strainer with 20 mesh screen 8 Evaporator Manual Air Vent Valve w/Plug A Isolator Unit for initial water loop cleaning B(b) Arrangement for Measuring Differential Pressure FT(c) Water Flow Switch Pi Pressure Gauge T1 Evaporator outlet temperature sensor T2 Evaporator inlet temperature sensor T3 Evaporator core temperature sensor T4 Chiller inlet temperature gauge T5 Chiller outlet temperature gauge (a) Strainer with 20 mesh screen is required. (b) Must account for water head difference when calculating total unit pressure differential. CG-SVX038A-EN 21 Unit Piping Figure 4. Condenser piping schematic Optional Water Regulating Valve Vibration Eliminator Temperature Gauge Valve for Pressure Measurement Isolation Valve T Condenser Out Pressure Gauge Bypass Valve P T Condenser In Isolation Valve Valve for Pressure Measurement Temperature Gauge Vibration Eliminator UNIT FACTORY INSTALLED OPTIONS CUSTOMER PIPING (IF ORDERED) 22 CG-SVX038A-EN Unit Piping Water Pressure Drop Curves Figure 5. Evaporator water pressure drop p p 20.00 20 TON 35 18.00 30 TON 30 16.00 Pressure Drop, psi 65 TON 25 12.00 40 TON 20 10.00 15 8.00 6.00 10 Pressure Drop, ft of H2O 50 TON 14.00 4.00 5 2.00 0 0.00 0 50 100 150 200 250 Flow, GPM Figure 6. Condenser water pressure drop 25.00 18.00 20 TON 16.00 30 TON 20.00 Pressure Drop, psi 12.00 50 TON 15.00 10.00 40 TON 65 TON 8.00 10.00 6.00 4.00 Pressure Drop, ft of H2O 14.00 5.00 2.00 0.00 0.0 50.0 100.0 150.0 200.0 0.00 250.0 Flow, GPM CG-SVX038A-EN 23 Unit Piping Low Suction Temperature and Pressure Cutouts/ Percent Glycol Recommendations Table 9 shows the low suction temperature and pressure cutouts for different glycol levels. For some operating conditions this effect can be significant. Additional glycol beyond the recommendations will adversely affect unit performance. The unit efficiency will be reduced and the saturated evaporator temperature will be reduced. If additional glycol is used, then use the actual percent glycol to establish the Low and Unsafe refrigerant suction pressure cutout set points. Table 9. Minimum recommended setpoints Ethylene Glycol/Water Glycol Solution % Freeze LOW UNSAFE (By Point SUCTION(a) SUCT(b) (psig) Mass) (°F) (psig) Propylene Glycol/Water FREEZE(c)(d) (°F) CORE FREEZE(e) (°F) Glycol Solution % Freeze LOW UNSAFE (By Point SUCTION(a) SUCT(b) (psig) Mass) (°F) (psig) FREEZE(c)(d) (°F) CORE FREEZE(e) (°F) 0 2 4 32.0 30.9 29.9 101.12 98.87 96.86 71.58 69.79 68.18 38.0 36.9 35.9 0 2 4 32.0 30.9 29.7 101.12 98.87 96.46 71.58 69.79 67.86 38.0 36.9 35.7 5 6 8 29.4 28.8 27.5 95.86 94.67 92.13 67.39 66.44 64.42 35.4 34.8 33.5 5 6 8 29.1 28.5 27.3 95.26 94.08 91.75 66.91 65.97 64.12 35.1 34.5 33.3 10 12 14 26.2 24.6 23.0 89.64 86.63 83.69 62.44 60.06 57.73 32.2 30.6 29.0 10 12 14 26.1 24.8 23.6 89.45 87.00 84.78 62.29 60.35 58.60 32.1 30.8 29.6 15 16 18 22.2 21.3 19.6 82.24 80.63 77.65 56.59 55.32 52.98 28.2 27.3 25.6 15 16 18 22.9 22.1 20.7 83.51 82.06 79.57 57.59 56.45 54.49 28.9 28.1 26.7 20 22 24 17.9 15.9 13.7 74.75 71.42 67.86 50.69 48.08 45.30 23.9 21.9 19.7 20 22 24 19.2 17.5 15.6 76.96 74.07 70.92 52.43 50.16 47.69 25.2 23.5 21.6 25 26 28 12.7 11.4 9.2 66.28 64.27 60.95 44.07 42.50 39.91 18.7 17.4 15.2 25 26 28 14.6 13.7 11.5 69.30 67.86 64.42 46.42 45.30 42.62 20.6 19.7 17.5 30 32 34 6.7 4.2 1.4 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 30 32 34 9.2 6.6 3.9 60.95 60.65 60.65 39.91 39.68 39.68 15.2 15.0 15.0 35 36 38 -0.2 -1.5 -4.6 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 35 36 38 2.5 0.8 -2.5 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 40 42 44 -8.1 -11.7 -15.5 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 40 42 44 -6.0 -9.8 -14.0 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 45 46 48 -17.6 -19.7 -24.0 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 45 46 48 -16.1 -18.3 -23.1 60.65 60.65 60.65 39.68 39.68 39.68 15.0 15.0 15.0 50 -28.9 60.65 39.68 15.0 50 -28.3 60.65 39.68 15.0 (a) “LOW SUCTION” refers to the low suction pressure cutout. (b) “UNSAFE SUCT” refers to the unsafe suction pressure cutout. (c) “FREEZE” refers to the low leaving fluid temperature cutout. (d) The minimum leaving fluid temperature set point, “CW OUT TRGT,” should not be less than 5°F above the low fluid temperature cutout, “FREEZE,” and the core fluid temperature cutout, “CORE FREEZE.” (e) “CORE FREEZE” refers to the evaporator core fluid temperature cutout. 24 CG-SVX038A-EN Unit Piping Refrigerant Piping (CCAR only) Note: If using a Trane CAUJ air-cooled condenser with a Trane CCAR compressor chiller, please refer to the Application Guide - Pairing Trane CCAR Compressor Chillers with Trane CAUJ Air-Cooled Condensers SS-APG014*-EN. This guide provides line sizing, field-component selection, application considerations and more. If not using a Trane CAUJ air-cooled condenser, please consider the following general guidelines and recommendations when designing your split system. Refer to the industry standards for refrigerant piping selection information; contact the factory if you do not have access to this data. Refrigerant pipe size selected must be within the velocity and pressure drop limitations required for proper system operation. It is essential that refrigerant piping be properly sized and applied since these factors have a significant effect on performance. Note: Use Type K refrigerant-grade copper tubing only. The use of a lower grade tubing can cause operating problems. General Guidelines Keep these general guidelines in mind as you review the recommendations specific to field piping refrigerant lines: • Limit overall line length. Enough sub-cooling may be lost as refrigerant travels up the liquid riser to cause flashing. Review any questionable applications with the factory. • Pipe sizing software such as Trane Engineering Toolbox can help to quickly determine proper sizes for refrigerant lines based on current engineering data. Liquid Line Sufficient sub-cooling must be maintained at the expansion valve. To provide proper operation throughout the range of operating conditions, the liquid-line pressure drop should not exceed the unit’s minimum sub-cooling value less 5°F. To achieve this objective, keep these liquidline considerations in mind: 1. Select the smallest, practical line size for the application. Limiting the refrigerant charge improves compressor reliability. 2. When designing the liquid line for a typical airconditioning application (i.e., one with an operating range of 40°F to 110°F), remember that every 10 feet of vertical rise will reduce sub-cooling by 2.8°F, while every 10 feet of vertical drop will add 1.1°F of subcooling. 3. Provide a 1-inch pitch toward the evaporator for every 10 feet of run. CG-SVX038A-EN 4. If the liquid line must be routed through an area warmer than outdoor air temperature, insulate the line to prevent the refrigerant from flashing. 5. A replaceable core liquid line filter drier must be installed as close as possible to the compressor chiller. The core should be changed whenever the system is opened for service. Trane compressor chillers do not include a filter-drier as standard, but one may be ordered if the installing contractor desires a factory type. 6. A moisture-indicating sight glass permits a visual check of the liquid column for bubbles. Sight glasses are included on the Trane compressor-chiller. However, never use the sight glass to determine whether the system is properly charged! Instead, either charge the system based on the required sub-cooling or calculate the amount of refrigerant needed and add it based on weight. Discharge (Hot Gas) Line Limit the pressure drop in the discharge line to 6 psid whenever possible to minimize the adverse effect on unit capacity and efficiency. While a pressure drop of as much as 10 psid is usually permissible, note that a 6-psid pressure drop reduces unit capacity by 0.9 percent and efficiency by 3 percent. Pitch discharge lines in the direction of hot gas flow at the rate of 1/2-inch per each 10 feet of horizontal run. Discharge line sizing is based on required velocity to provide good oil movement. Basic discharge line parameters are: Max allowable pressure drop 6 psig (1F) Maximum Velocity 3500 fpm Minimum Velocity (at minimum load) Horizontal lines 500 fpm Vertical lines (up flow) 1000 fpm To design the discharge line properly, follow the recommended guidelines: • Choose the shortest route from the compressor to the condenser. • Use different pipe sizes for horizontal and vertical lines to make it easier to match line pressure drop and refrigerant velocity to discharge-line requirements. • To assure proper oil entrainment and avoid annoying sound levels, size the discharge line so refrigerant velocity equals or exceeds the minimum velocity in Table 10 and remains below 3,500 fpm. • Prevent oil and condensed refrigerant from flowing back into the compressor during “off” cycles by: a. pitching the discharge line toward the condenser, and b. routing the discharge line so that it rises to the top of the condenser, then drops to the level of the condenser inlet, creating an inverted trap. 25 Unit Piping • Double risers are generally unnecessary. The scroll compressors in Trane units unload to the extent that a single, properly sized riser can transport oil at any load condition. Table 10. Minimum discharge-line velocities for oil entrainment Refrigerant Velocity, fpm Nom. Pipe Size, in. Riser Horizontal 7/8 375 285 1-1/8 430 325 1-3/8 480 360 1-5/8 520 390 2-1/8 600 450 • Riser traps are also unnecessary. Avoid using riser traps. If the discharge riser is sized to maintain the proper refrigerant velocity, adding a trap will only increase the pressure drop. Reliability determines the success of a split airconditioning system. Interconnecting refrigerant lines play an instrumental role in that success. It’s up to us to ensure that our system design practices evolve with equipment technologies. This can be summarized as five fundamental “rules”: 1. Choose the right system (i.e., don’t specify splitsystem equipment when a packaged chiller is best suited for the job). Final Leak Test WARNING Hazard of Explosion! Failure to follow instructions below could result in death or serious injury or equipment or property-only damage. Use only dry nitrogen with a pressure regulator for pressurizing unit. Do not use acetylene, oxygen or compressed air or mixtures containing them for pressure testing. Do not use mixtures of a hydrogen containing refrigerant and air above atmospheric pressure for pressure testing as they may become flammable and could result in an explosion. Refrigerant, when used as a trace gas should only be mixed with dry nitrogen for pressurizing units. Once refrigerant piping is completed, thoroughly test the system for leaks. System Evacuation WARNING Risk of Internal Arc Flash! Failure to follow instructions could result in death, serious injury and compressor damage. Do not use a megohmmeter or apply power to compressor windings under vacuum as it could result in an arc flash inside the compressor. 4. Minimize the length of the interconnecting tubing. For field evacuation after leak checking, use a vacuum pump capable of pulling a vacuum of 100 microns or less. Follow the pump manufacturer’s instructions for proper use of the pump. Insure that all sections of the system are properly evacuated before proceeding. 5. Keep the system clean. Refrigerant Charging 2. Size the interconnecting lines to avoid the use of traps and double risers. 3. Slope the liquid lines toward the evaporator. Initial Leak Test As shipped, Trane compressor-chillers contain a holding charge of nitrogen only. Before connecting refrigerant piping, momentarily crack open a Schraeder valve on the liquid line to insure that the unit is still pressurized. If no gas escapes thru the valve, leak test the unit to determine the source of the refrigerant leak prior to installation and repair any leaks located. Refrigerant Piping Sizes Refer to the Trane guide TRG-TRC006-EN and/or ASHRAE publications to determine piping selection information. Refrigerant pipe sizes selected must be within the velocity and pressure drop limitations required for proper system operations. It is essential that refrigerant piping be properly sized and applied since these factors have a significant effect on system performance and reliability. NOTICE: Equipment Damage! To prevent damage to the evaporator and condenser, never charge liquid refrigerant into either of these vessels without adequate flow to prevent the temperature/pressure relationship to fall below 35°F. Once the system is properly installed, leak tested and evacuated, refrigerant charging can begin. Liquid refrigerant must be charged into each circuit through the liquid line access with the compressor(s) off. Charge refrigerant into the system by weight. Use an accurate scale or charging cylinder to determine the exact charge entering the system. Failure to charge the system accurately can lead to under or over-charging and result in unreliable operation. If system pressure equalize before the full charge enters the system, close the charging port and proceed to start-up procedure. 26 CG-SVX038A-EN Electrical Wiring WARNING Proper Field Wiring and Grounding Required! Failure to follow code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. General Recommendations WARNING Hazardous Service Procedures! Failure to follow all precautions in this manual and on the tags, stickers, and labels could result in death or serious injury. Technicians, in order to protect themselves from potential electrical, mechanical, and chemical hazards, MUST follow precautions in this manual and on the tags, stickers, and labels, as well as the following instructions: Unless specified otherwise, disconnect all electrical power including remote disconnect and discharge all energy storing devices such as capacitors before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. When necessary to work with live electrical components, have a qualified licensed electrician or other individual who has been trained in handling live electrical components perform these tasks. NOTICE: Use Copper Conductors Only! Failure to use copper conductors could result in equipment damage as the equipment was not designed or qualified to accept other types of conductors. The wiring procedures, as described in this portion of the manual, must be accomplished to obtain proper operation of the unit. All wiring must comply with National Electrical Code (NEC) and state and local requirements. Outside the United States, the national and/or local electrical requirements of other countries shall apply. The installer must provide properly sized system interconnecting and power supply wiring with appropriate fused disconnect switches. Type and locations of disconnects must comply with all applicable codes. Minimum circuit ampacities, recommended fuse sizes and other unit electrical data are provided on the unit nameplate. CG-SVX038A-EN Power and Control Wiring Unit Power Wiring The installing contractor must connect appropriate power wiring (with fused disconnects) to the terminal block or non-fused, unit-mounted disconnect in the power section of the unit control panel. Electrical schematics and component location drawings are also mounted on the inside of the control panel door. The unit power fused disconnect switch should be located in the general area of the unit, to comply with NEC or local codes. Some codes require line-of-sight disconnect locations. The optional unit unfused disconnect can be used as an emergency shutdown device. Scroll Compressor Electrical Phasing General WARNING Hazardous Voltage! Failure to disconnect power before servicing could result in death or serious injury. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. NOTICE: Compressor Damage! Operating compressors in reverse rotation will cause damage or failure of the compressor. It is critical that proper rotation of the scroll compressors be established before the machine is started. Proper motor rotation requires confirmation of the electrical phase sequence of the power supply. The motor is internally connected for clockwise rotation with the inlet power supply phased “ABC” or “L1, L2, L3”. The order in which the three voltages of a three-phase system succeed one another is called phase sequence or phase rotation. When rotation is clockwise, phase sequence is usually called “ABC” and when counterclockwise, “CBA”. This direction may be reversed by interchanging any two of the line wires. It is this possible interchange of wiring that makes a phase sequence indicator necessary, if the operator is to quickly determine the phase rotation of the motor. Setting Proper Electrical Phase Sequence Proper compressor motor electrical phasing can be quickly determined and, if necessary, corrected before starting the unit. Use a quality instrument, such as an Associated 27 Electrical Wiring Research Model 45 Phase Sequence indicator or equivalent and follow this procedure. 1. Verify that all operating controls for the unit are in the “Off” position. 2. Disconnect power to the power distribution block in the unit control panel 3. Connect the phase sequence indicator leads to the power distribution block as follows: Voltage Imbalance Excessive voltage imbalance between phases in a threephase system will cause motors to overheat and eventually fail. Maximum allowable imbalance is 2 percent. Voltage imbalance is defined as 100 times the maximum deviation of the three voltages (three phases) subtracted from the average (without regard to sign), divided by the average voltage. Example: Phase Seq. Lead Terminal ID Black (Phase A) L1 Red (Phase B) L2 If the three voltages measured at the line voltage fused disconnect are 221 volts, 230 volts and 227 volts, the average would be: Yellow (Phase C) L3 221 + 230 + 227 = 226 volts 4. Turn power on by closing the unit supply power fused disconnect switch. 5. Read the phase sequence displayed on the indicator. The “ABC” LED on the face of the phase indicator will glow if phase sequence is ABC. 6. If the “CBA” indicator glows instead, open the unit main power disconnect and switch two line leads on the power distribution block in the unit control panel. Close the main power disconnect and recheck phasing. 7. Open the unit disconnect and remove the phase indicator. 3 The percentage of imbalance is then: 100 (226-221) = 2.2% 226 In the preceding example, 221 is used because it is the farthest from the average. The 2.2 percent imbalance that exists exceeds maximum allowable imbalance by 0.2 percent. This much imbalance between phases can equal as much as 20 percent current imbalance with a resulting increase in winding temperature that will decrease compressor motor life. Unit Voltage Control Power Supply Electrical power to the unit must meet stringent requirements for the unit to operate properly. Total voltage supply and voltage imbalance between phases should be within the tolerances discussed below. A fused, panel-mounted control power transformer is standard on all units. Replacement fuses are listed on the “Fuse Schedule” decal located adjacent to the transformer inside the control box. Voltage Supply External Contacts WARNING Live Electrical Components! Chilled Water Flow Switch Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. When necessary to work with live electrical components, have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Measure each leg of supply voltage at the line voltage disconnect switches. Readings must fall within the range of 187-254 volts for units with a nameplate voltage of 208/230 volt and 414-508 volts for units with a nameplate voltage of 460 volts. If voltage on any leg does not fall within tolerance, notify the power company and request correction of this situation before operating the unit. Inadequate voltage to the unit will shorten the life of relay contacts and compressor motors. 28 The unit controller has an input that accepts a contact closure from a proof-of-flow device such as a flow switch or other factory approved flow proving device. When this input does not prove flow within a fixed time relative to transition from enabled to run modes of the chiller, or if the flow is lost while the chiller is in the running mode of operation, the chiller will be prohibited from running. The installer must provide and install this flow proving device. See also wiring diagrams attached to the inside of the control panel door. Failure to provide this flow proving device voids unit warranty. CG-SVX038A-EN Electrical Wiring NOTICE: Unexpected Chiller Start! Failure to follow instructions could cause the chiller to start unexpectedly which could result in equipment or property damage. An external source (EMS, time clock or any other means) should not be allowed to bring on a pump that would trigger the flow switch to start the chiller. The flow switch is meant to act as a safety switch and not a start/stop mechanism. CCAR Condenser Fan Staging or VFD Control The CCAR compressor chiller unit controller has the ability to control fan staging, fan VFDs and damper control in order to improve the stability of discharge pressure at various ambient conditions. Unit controller capability single circuit compressor chillers (CCAR 20, and 30) have three dry contact relays to cycle condenser fan motors to control discharge pressure, as well as one 0 to 10 Vdc analog output to control a VFD or fan damper. Dual circuit compressor chillers (CCAR 40, 50, and 65) have six dry contact relays to cycle condenser fan motors to control discharge pressure, as well as two 0 to 10 Vdc analog output to control a VFD or fan damper. CCAR unit controller must control condenser ambient control devices such as fan cycling and optional low ambient dampers. As a result the interconnecting field wiring must be done by others. For pairing CCAR compressor chiller with CAUJ air cooled condenser, the following field wiring is to be done by others. • Fan cycling control • One control wire for each condenser fan plus a common must be run between CCAR compressor chiller and CAUJ condenser. • Required fan control wiring for CCAR compressor chillers matched with CAUJ condensers utilizing fan control are covered by schematic, instructions, and associated footnotes on Figure 21, p. 53 and Figure 22, p. 54. • Low Ambient Dampers (when applicable) • One shielded pair for each condenser damper assembly must be run between CCAR compressor chiller and CAUJ air cooled condenser. • Required damper control wiring for CCAR compressor chillers matched with CAUJ condensers utilizing low ambient control damper assembly are covered by schematic, instructions and associated footnotes on Figure 23, p. 55 and Figure 24, p. 56. CG-SVX038A-EN CGWR Condenser Water Loss of Flow Protection The controller logic will sense a loss of flow through the condenser. No flow switches are necessary with the standard unit controller configuration. CGWR Condenser Control CGWR units have one dry contact relay to start a condenser pump. These chillers also have one 0 to 10 Vdc analog output to control a head pressure control valve. Consult wiring diagram located inside the control box door for connection point(s). Equipment Grounds NOTICE: Use Copper Conductors Only! Failure to use copper conductors could result in equipment damage as the equipment was not designed or qualified to accept other types of conductors. Provide proper grounding at the connection point provided in the unit control panel. Unit Controller Note: The unit controller section in this IOM contains only a brief overview of the unit controller. Please consult the Unit Controller Version 17 Manual Rev. 3.0 for Cold Generator™ Chillers (CG-SVX030*-EN) which documents the function of the unit controller including setpoint definitions, points lists and much more. The unit controller is a rugged microprocessor based controller designed for the hostile environment of the HVAC/R industry. It is designed to be the primary manager of the CCAR/CGWR product. The unit controller provides flexibility with setpoints and control options that can be selected prior to commissioning a system or when the unit is live and functioning. Displays, pressures, temps, alarms and other interfaces are accomplished in a clear and simple language that informs the user as to the status of the controller. Refer also to the wiring diagram attached to the inside of the control panel door. A password is required to access controller setpoints. Use password code 2112 to access many of these features. A factory code may be required to allow access to critical areas, and can only be entered by a factory representative. A RS-485 port is provided for communication with other manufacturers’ systems. Additionally, a built-in RS-485 to RS-232 converter allows communication over the RS-485 port via the RS-232 port. Other features include the integration of BACnet® IP and MODBUS® into the unit controller. An optional gateway card allows 29 Electrical Wiring communication via BACnet® MSTP, Johnson N2, and LONWORKS®, and this should be ordered with the chiller if required. An ethernet connection is also provided on each unit. While field changes can be made, please insure that the unit is ordered set up for required communications to insure that factory testing includes end user configuration. A complete software support package is available for your PC allowing for system configuration, dynamic on-line display screens, remote communication, graphing and more. See “Downloading and Installing Unit Controller (MCS-Connect) Software,” p. 31 for download instructions. All information needed to run the unit is available from the unit display; however, a laptop computer is invaluable for ease of use of diagnosing or changing the unit setpoints. Note: Not all setpoints can be changed with MCS-Connect; some require a configuration change. A serial cable is included in each shipment for the convenience of the field tech. If you do not have a laptop with a serial port, you will require a converter such as a Black Box item number #IC199A-R3 serial-to-USB adaptor. The standard configuration allows for unit to start at lowest stage possible, then add compressors as needed to meet demand. Important: 30 All configuration changes need to be done by factory representatives to ensure proper operation of the unit within design parameters. Refer to MCS unit controller manual for sequence of operation and additional details. CG-SVX038A-EN Unit Controller—Software Installation and Setup Downloading and Installing Unit Controller (MCS-Connect) Software Go to www.nappstech.com. Click on Downloads in the grey bar and select MCS-CONNECT. Select SAVE. After downloading, open and select RUN. Follow prompts and software will be installed on your computer. If your computer does not have a serial port, you will need to purchase a USB to Serial adapter. (Computer stores should have this.) Install the software for the adapter. If your computer has a serial port, you will not need an adapter. You will need to know which Port your computer uses as the COM PORT. In Microsoft® Vista, go to the CONTROL PANEL and select DEVICE MANAGER. Look for PORTS (COM & LPT), expand and you should see a COM PORT number. Windows® 7 is similar. Start the MCS-CONNECT software. Select SETUP>COMMUNICATIONS and then change LOCAL COM PORT to match your computer. Select SAVE and then OK. Connecting to the Chiller Connect the supplied NULL MODEM cable between your USB adapter or serial port to the chiller. A standard serial cable will not work. Start the MCS-CONNECT software and select LOCAL SERIAL. You will see the site info page. The software should scan and find the chiller. (If you see a Failed to open comm port error, or it scans and does not find the chiller, your comm port settings are not correct.) Click the 1-CCAR/CGWR tab. The screen shows real time data. Set Point Changes Click the VIEW ONLY button. Enter the password code 2112. Select OK. Button should say SERVICE. Go to set points and double-click on a value. Change and select OK. Viewing and Troubleshooting ALARMS The unit controller will record and store 30-second sensor input data prior to and up to any LOCKOUT ALARM. Select the ALARM tab, then INFO next to the alarm you want to analyze. This will pop up a screen that shows operating conditions just prior to the trip. You can easily determine if the fault was caused by a sudden or gradual change. For instance, a sudden increase in discharge pressure might suggest a condenser pump or fan failure etc. (This data can also be viewed from the chiller LCD screen. Select LOCKOUT ALARMS.) CG-SVX038A-EN Downloading and Viewing Graphs The unit controller continuously records and stores sensor input and relay/analog output data. This data is collected in 10-second (default) intervals. The controller stores 1008 packets of data replacing the oldest with the newest. With the time interval set at 10 seconds, you can download graph data with a time span of 168 minutes. The time interval is adjustable. In the MCS-CONNECT software, select GRAPH. Data will be downloaded and then a graph setup page will appear. Select the input and output data you want to look at. Type in Y-axis parameters and select OK. Use the scroll bar at the bottom of the graph to view. You can go back to the setup page at any time to change selections. You may save the graph to view later. You don’t have to be connected to view a saved graph file. Your saved graph will be located in a folder called GRAPH inside another folder called MCS on your C: drive. To change the default 10-second interval, make changes and select SAVE and then OK on the setup page. The controller will now record data at this new interval. To view a saved graph, select LOAD A GRAPH FILE. These files can be e-mailed to us for analysis if needed. Updating Chiller Software and Configuration Files Trane chillers are programmed, set up, and tested prior to shipment. Sometimes after a unit arrives at the jobsite, the customer may want to enable an option such as 0–5 Vdc target reset or chilled water pump control etc. These options require a configuration change. We will either have you download the configuration file from the chiller and e-mail it to us where we will modify it and return it to you, or we will modify a default configuration file we have here at the factory and send it to you. Modifying a configuration file you send us will save any setpoint changes that have been made on site. Otherwise, the controller will be set back to default factory settings. To e-mail us a copy of your chiller’s configuration file, in the MCS-CONNECT software, establish communication with the chiller and select RECEIVE CFG. Name it something and e-mail it to [email protected]. To load a configuration file, turn off circuit enable switches and select TRANSMIT CFG. Locate the new file and press OPEN. The file will be uploaded to the controller. The controller will reboot itself. Routine software (HEX FILE) updates are NOT necessary. However, if we think a software update is necessary to resolve an operating issue you may be having, we will e-mail the hex file in a zipped folder. Save the zipped folder to your desktop. Right click folder and select EXTRACT ALL. This will create another folder by the same name on your desktop. Inside this folder you’ll find the hex file. It should be about 2300 KB large. 31 Unit Controller—Software Installation and Setup In the MCS-CONNECT software, select TRANSMIT SW. Locate the extracted hex file and select Transmit. Watch the chiller LCD screen. After the file is uploaded, the Trane MCS Digital Controller will verify that it’s a valid file and then erase the flash memory. Next, it will write the new hex to memory. When completed, the controller will reboot itself. This process may take 15 or 20 minutes. After the reboot is completed, close and restart the MCS-CONNECT software to reestablish communication with the chiller. 32 CG-SVX038A-EN Unit Startup Procedures NOTICE: Compressor Failure! NOTICE: Equipment Damage! To protect compressors from premature failure the unit must be powered and crankcase heaters energized at least 24 hours BEFORE compressors are started. • To prevent overheating at connections and undervoltage conditions at the compressor motor, check tightness of all connections in the compressor power circuit. • To prevent compressor damage, do not operate the unit with discharge or liquid line service valves closed. • The use of untreated or improperly treated water in a Chiller may result in scaling, erosion, corrosion, algae or slime. It is recommended that the services of a qualified water treatment specialist be engaged to determine what water treatment, if any, is required. The Trane Company assumes no responsibility for equipment failures which result from untreated or improperly treated water, or saline or brackish water. • To prevent evaporator or condenser damage, pipe strainers must be installed in the water supplies to protect components from water born debris. Trane is not responsible for equipment damage caused by water born debris. Prior to calling for start-up services or commissioning, CG-ADF005*-EN (CGWR Installation Completion Check List and Request for Trane Service) or CG-ADF006*-EN (CCAR Installation Completion Check List and Request for Trane Service), as appropriate, must be completed and submitted. Once CG-ADF005*-EN or CG-ADF006*-EN has been submitted, CG-ADF007*-EN (Start-up Check List for CGWR and CCAR Chillers) must be followed and submitted. Pre-Start Up Procedures Check List Complete each step in the “Pre-Start Up Procedures” check list included in CG-ADF007*-EN (Start-up Check List for CGWR and CCAR Chillers) and check off each step as completed. WARNING Hazardous Voltage! Failure to disconnect power before servicing could result in death or serious injury. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. Sequence of Operation Power Applied to Unit Controller Call for Cooling Auto (Power up Start Delay) Auto Unit Controller Boot Time Enforce Power Up Start Delay Time Confirm Evaporator Water Flow (24 to 90 Sec) (30 to 120 Sec) (6 to 600 Sec) Chiller Level Auto Waiting to Start Running (0 to 5 Sec) Energize Condenser Water Pump Relay (Only if Chiller Controls Pump) Lead Circuit Auto Auto Auto Running Enforce Restart Inhibit Timer (0 to 5 Mins) Lag Circuit CG-SVX038A-EN Open Solenoid Valve Energize Lead Compressor Auto 33 Unit Startup Procedures Checking Operating Conditions NOTICE: Evaporator/Condenser Damage! Water (fluid) flow must be established in evaporator and condenser before adding refrigerate, removing refrigerate, or pulling vacuum, to protect heat exchangers from freezing. NOTICE: Compressor Damage! Do not allow liquid refrigerant to enter the suction line as excessive liquid accumulation in the liquid lines could result in compressor damage. To prevent compressor damage and ensure full cooling capacity, use refrigerants specified on the unit nameplate only. • If operating conditions indicate an overcharge, slowly (to minimize oil loss) remove refrigerant at the liquid line Schrader fitting. Do not discharge refrigerant into the atmosphere. • If the remote condenser (CCAR) is equipped with low ambient dampers, check for proper actuator and blade travel in relation to condensing pressure. • Once proper unit operation is confirmed, inspect for debris, misplaced tools., etc. Secure control panel doors in place. Once the unit has been operating for about 10 minutes and the system has stabilized, check operating conditions and complete the checkout procedures that follow. • Recheck evaporator water and condenser (CGWR) water flows and pressure drops. These readings should be stable at proper levels. • Check suction pressure and discharge pressure of the unit. restriction can often be identified by a noticeable temperature differential on either side of the restricted area. Frost often forms on the outside of the liquid line at this point also. The system may not be properly charged although the sight glass is clear. Also consider superheat, sub-cooling and operating pressure. • Once oil level, amp draw and operating pressures have stabilized, measure system suction superheat. • Measure system liquid line sub-cooling. • If operating pressure, sight glass, superheat and subcooling readings indicate refrigerant shortage, charge refrigerant into each circuit. Refrigerant shortage is indicated if operating pressures are low and subcooling is also low. If suction and discharge pressures are low but subcooling is normal, no refrigerant shortage exists. Adding refrigerant, will result in overcharging. Add refrigerant with the unit running by metering liquid refrigerant through the Schrader valve between the expansion valve and the evaporator refrigerant inlet until operating conditions are normal. System Superheat Normal superheat for each circuit is 10°F–16°F at full load. If superheat is not within this range, adjust expansion valve superheat setting. Allow 5–10 minutes between adjustments for the expansion valve to stabilize on each new setting. System Sub-cooling Normal sub-cooling for each circuit is 5°F to 10°F at full load where saturated discharge pressure and liquid line temperature are measured at chiller liquid line. Discharge pressures—take at Schrader fitting provided on the discharge line. Normal discharge pressures are: CCAR units: 315 psig to 500 psig CGWR units: 275 psig to 430 psig Suction pressures— take at Schrader fitting provided on the suction line. Normal suction pressures are: 42°F–60°F LWT: 104–155 psig 15°F–39°F LWT: 60–103 psig • Check compressor oil levels. At full load, oil level should be visible in the oil level sight glass on the compressor. If it is not, add or remove oil as required. • Check the liquid line sight glasses. Refrigerant flow past the sight glasses should be clear. Bubbles in the liquid line indicate either low refrigerant charge or excessive pressure drop in the liquid line. Such a 34 CG-SVX038A-EN Unit Shutdown Normal Unit Shutdown Local Stop Normal Latching Diagnostic Chiller Level Non-Latching Diagnostic Tracer Stop External Auto-Stop Chiller Level Running Stopped Run Inhibit Shutting Down Stopped or Run Inhibit Evap Pump Off Delay Timer (0 to 30 Minutes) De-Energize Condenser Water Pump Relay (If Chiller Controls Pump) Circuit 1 Auto Shutting Down (1 to 5 Sec) De-Energize Current Lead Cprsr De-Energize Current Lag Cprsr Close Liquid Solenoid Valve Circuit 2 Auto Shutting Down (1 to 5 Sec) De-Energize Cprsr Close Liquid Solenoid Valve Extended Shutdown Procedure If the system is taken out of operation for long periods of time, use this procedure to prepare the system for shutdown. 1. Test condenser and high side piping for refrigerant leakage. 2. Open electrical disconnect switches for evaporator water pump. Lock the disconnect in an open position. 3. Open the unit main electrical disconnect and unitmounted disconnect (if used) and lock in open position. CG-SVX038A-EN 35 Unit Restart Unit Restart After Extended Shutdown Use this procedure to prepare the system for restart after an extended shutdown. NOTICE: Compressor Failure! To protect compressors from premature failure the unit must be powered and crankcase heaters energized at least 24 hours BEFORE compressors are started. NOTICE: Compressor Damage! To prevent compressor damage, be certain that all refrigerant valves are open before starting the unit. 1. Close the unit main disconnect(s) and the unitmounted disconnect (if used). 2. Check compressor crankcase oil levels. Oil should be visible in the compressor oil level sight glass. 3. Fill the chilled water circuit(s) if drained during shutdown. Vent the system while filling it. 4. Close the fused disconnect switch(es) for the water pumps. 5. Start the water pump(s). With water pumps running, inspect all piping connections for leakage. Make any necessary repairs. 6. With water pump(s) running, adjust chilled water flow and check water pressure drop through the evaporator. 7. Check the flow switch on the evaporator outlet piping for proper operation. 8. Stop the water pump(s). 9. Complete each step in Trane literature CGWR-ADF002*-EN (Start-up Check List for CGWR and CCAR Chillers). 10. Energize Crankcase Heaters (Must be energized 24 hours before startup). 36 CG-SVX038A-EN Maintenance WARNING Hazardous Service Procedures! Failure to follow all precautions in this manual and on the tags, stickers, and labels could result in death or serious injury. Technicians, in order to protect themselves from potential electrical, mechanical, and chemical hazards, MUST follow precautions in this manual and on the tags, stickers, and labels, as well as the following instructions: Unless specified otherwise, disconnect all electrical power including remote disconnect and discharge all energy storing devices such as capacitors before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. When necessary to work with live electrical components, have a qualified licensed electrician or other individual who has been trained in handling live electrical components perform these tasks. Because scroll compressors are a uniquely different design from traditional reciprocating compressors, their operating characteristics and requirements are a departure from the reciprocating compressor technology. Compressor Oil The R-410A scroll compressor uses POE oil as required by the manufacturer of the compressor. Refer to compressor manufacturer for exact type and amount of oil in the specific model in question. Scroll Compressor Functional Test Since the scroll compressor does not use discharge or suction valves, it is not necessary to perform a pumpdown capability test, i.e. a test where the liquid line valve is closed and the compressor is pumped in a vacuum to see if it will pump-down and hold. If fact, this kind of test may actually damage the scroll compressor! NOTICE: Compressor Damage! Do not pump the scroll compressor into a vacuum. Scroll compressors can pull internal low vacuums when the suction side is closed or restricted. This, in turn, may cause the internal Fusite® terminal to arc, resulting in compressor damage or failure. It may also trip the circuit breakers, blow fuses, or trip the discharge thermostat. The proper procedure for checking scroll compressor operation is outlined below: 1. Verify that the compressor is receiving supply power of the proper voltage. 2. With the compressor running, measure the suction and discharge pressures/temperatures to determine whether or not they fall within the compressor operating map shown in figure below. See “Checking Operating Conditions,” p. 34 for normal operating pressure ranges for the unit. Oil Level. While the compressor is running, the oil level may be below the sight glass but still visible through the sight glass. The oil level should NEVER be above the sight glass! Oil Appearance. If the oil is dark and smells burnt, it was overheated because of compressor operation at extremely high condensing temperatures, a compressor mechanical failure, or occurrence of a motor burnout. If the oil is black and contains metal flakes, a mechanical failure has occurred. This symptom is often accompanied by a high amperage draw at the compressor motor. Notes: • If a motor burnout is suspected, use an acid test kit to check the condition of the oil. If a burnout has occurred, test results will indicate an acid level exceeding 0.05 mg KOH/g. • The use of commercially available oil additives is not recommended. Liability for any detrimental effects that the use of non-approved products may have on equipment performance or longevity must be assumed by the equipment owner, equipment servicer, or the oil additive manufacturer. CG-SVX038A-EN 37 Maintenance Figure 7. Compressor operating map Compressor Operating Map Saturated Condensing Temperature (°F) 150 140 130 120 110 100 90 80 70 -10 0 10 20 30 40 50 60 70 80 Saturated Evaporating Temperature (°F) Compressor Operational Noises Because the scroll compressor is designed to accommodate liquids (both oil and refrigerant) and solid particles without causing compressor damage, there are some characteristic sounds that differentiate it from those typically associated with a reciprocating compressor. These sounds, which are described below, are normal and do not indicate that the compressor is defective. At low ambient startup: When the compressor starts up under low ambient conditions, the initial flow rate of the compressor is low. Under these conditions, it is not unusual to hear the compressor rattle until the suction pressure climbs and the flow rate increases. These sounds are normal and do NOT affect the operation or reliability of the compressor. Note: Operation of the chiller with saturated suction temperatures below freezing will cause damage to the evaporator. If this occurs immediately stop the machine, diagnose and correct the problem. Periodic Maintenance Perform all of the indicated maintenance procedures at the intervals scheduled. This will prolong the life of the unit and reduce the possibility of costly equipment failure. Weekly Maintenance Once the unit has been operating for about 10 minutes and the system has stabilized, check operating conditions and complete the checkout procedures that follow. • Check compressor oil levels. Oil should be visible in the sight glass when the compressor is running. Operate the compressors for a minimum of three to four hours when checking oil level, and check level every 30 minutes. If oil is not at proper level after this period, have a qualified service representative add or remove oil as required. • Check suction pressure and discharge pressure. • Check the liquid line sight glasses. • If operating pressures and sight glass conditions seem to indicate refrigerant shortage, measure system superheat and system sub-cooling. • If operating conditions indicate an overcharge, slowly (to minimize oil loss) remove refrigerant at the liquid line service valve. • Inspect remote condenser coils for cleanliness (CCAR only) and clean if required. Refer to the condenser manufacturer’s recommendations. Excessive Amp Draw Excessive Amp Draw occurs either because the compressor is operating at an abnormally high condensing temperature OR because of low voltage at the compressor motor. Motor amp draw may also be excessive if the compressor has internal mechanical damage. In this situation, vibration and discolored oil can also be observed. Low Suctions Continuous low suction pressures are most likely caused by low evaporator load coupled with a system anomaly. Symptoms that may accompany low suctions include a rattling sound emitted from the compressor or an open motor winding thermostat or discharge thermostat. 38 CG-SVX038A-EN Maintenance Inspect the entire system for unusual conditions. Use an operating log to record a weekly operating conditions history for the unit. A complete operating log is a valuable diagnostic tool for service personnel. Monthly Maintenance Once the unit has been operating for about 10 minutes and the system has stabilized, check operating conditions and complete the checkout procedures that follow. • Perform all weekly maintenance procedures. • Check refrigerant superheat at the compressor suction line. Superheat should be in the range of 10°F–20°F. Note: A superheat calculated value is incorporated into the unit controller. • Inspect the entire system for unusual conditions. Review the weekly operating log for conditions history for the unit and take note of any unusual trends in performance. Take appropriate preventative actions if necessary. Annually Perform all weekly and monthly maintenance procedures. • Have a qualified service technician check the setting and function of each control and inspect the condition of and replace compressor and control contacts if needed. • If chiller is not piped to drain facilities, make sure drain is clear to carry away system water. • Drain water from condenser (CGWR only) and evaporator and associated piping systems. Inspect all piping components for leakage, damage, etc. Clean out required evaporator strainer. • Inspect condenser tubes and clean, if needed. • Clean and repaint any corroded surface. • Clean remote condenser coils (CCAR only). Refer to the condenser manufacturer’s recommendations. CG-SVX038A-EN 39 Electrical Schematics CGWR Water-Cooled Chillers CGWR Field Wiring Figure 8. Field wiring for 20 to 65 ton, R-410A CGWR water-cooled chillers Control Panel Representation L1 L2 L3 PDB1 A-1 GND A-2 UNIT CONTROLLER Optional: Disconnect (Factory Installed) PANEL GROUND 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Optional : For CGWR 20-30 ton, Cooling Tower Pump Enable 4 WARNING Hazardous voltage! Disconnect all electrical power including remote disconnects before servicing unit. Follow proper lockout/ tagout procedures to ensure power cannot be inadvertently energized. Failure to do so can cause death or serious injury. 1 TBA DSW1 Optional : For CGWR 40-65 ton, Cooling Tower Pump Enable Optional : Alarm Dry Contacts 5 REQUIRED: Flow Switch (flow proving device) Optional: Remote Run/Stop Interface CAUTION Use copper conductors only! Unit terminals are not designed to accept other type conductors. Failure to use copper conductors may cause equipment damage. CAUTION Do not energize the unit until checkout and start-up procedures have been completed. Notes: 1. All three-phase motors supplied with the unit are protected under primary single-phase failure conditions. 2. All customer control-circuit wir ing must have a minimum rating of 150V. 3. All field wiring must be in accordance with applicable local codes. 4 4. Line voltage options. Single or dual source power may be specified. Drawing covers single source power only. All field wiring must be in accordance with National Electric Code and State & Local requirements. 5. (Required) Factory supplied or approved alternate field installed flow 5 proving device connection. NAME DATE DRAWN SMH 3/22/17 CHECKED BAR 3/22/17 ENG APPR. MFG APPR. Q.A. CGWR Field Wiring Diagram COMMENTS: SIZE DWG. NO. 40 REV. A CGWR Field Wiring 0 SCALE:1:5 WEIGHT: SHEET 1 OF 1 CG-SVX038A-EN 5 6 F3 3 CG-SVX038A-EN AMPS COMP 2 (CT 2) DIGITAL ANALOG (Shield tied at this end) MCS IORS485 +12V Termination + - GND DIGITAL ANALOG GND SI SENSOR 12 ETHERNET +5 UNIT CONTROLLER To Optional Exp Board Comm to SI16 or eq To Customer Interface or Communications Board WHITE BLACK SHIELD 115v Voltage ALARM RELAY M-10 SPARE RELAY M-9 NC Com NO CORE TEMP SENSOR M-12 WHITE DIGITAL ANALOG +5 GND SI SENSOR 11 BLACK SHIELD (PUMP) CND ENBL1 RELAY M-8 SPARE RELAY M-7 Com NO CKT 1 SUC TMP SENSOR M-11 GND SI SENSOR 10 DIGITAL ANALOG GND SI SENSOR 9 DIGITAL ANALOG GND SI SENSOR 8 DIGITAL ANALOG C2 RELAY M-6 NC SPARE +5 +5 DIGITAL ANALOG GND SI SENSOR 7 SPARE NC Com NO SENSOR M-10 SPARE +5 +5 GND SI SENSOR 6 RELAY M-5 SPARE NC Com NO SENSOR M-9 SPARE WHITE +5 DIGITAL ANALOG GND SI SENSOR 5 NC Com NO SENSOR M-8 SPARE BLACK & SHIELD WHITE +5 Com NO SENSOR M-7 WHITE BLACK & SHIELD GND N L/L1 20 19 18 17 16 15 9 5B 8 NC SENSOR M-6 AMPS COMP 1 (CT 1) 7 Com NO SENSOR M-5 DIGITAL ANALOG 6 NC RELAY M-4 HGS 1 RELAY M-3 LLS 1 RELAY M-2 C1 RELAY M-1 NC Com NO GND SI SENSOR 4 DIGITAL ANALOG GND SI SENSOR 3 DIGITAL ANALOG GND SI SENSOR 2 A-4 A-3 A-2 A-1 ANALOG OUTS NC Com NO +5 RED BLACK & SHIELD 24 Com NO CKT 1 DIS PSI TBA24 DIGITAL ANALOG 5A TBA20 TBA19 TBA18 TBA17 TBA16 TBA15 3A 8A TBA11 7A TBA10 4A HP1SW LP1SW 3D Comp 1 CONTACTOR C1 TBA1 TBA2 3 TBA5 TBA4 THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE IMPORTANT WHITE Comp 2 CONTACTOR C2 HOT GAS SOLENOID HGS 1 LIQUID SOLENOID LLS 1 3A 4 3 3G FU3 RED 1 TBC1 WHITE V+ VN ETHERNET L BY DA T E (OPTIONAL TOUCHSCREEN POWER SOURCE) # Y1 U + - 120 VAC TR1 POWER IN +12V GND ?? L1 L2 L3 PWM FU2 FU1 R E V I S I ON FU4 FU5 FU6 (OPTIONAL TOUCHSCREEN CONNECTIONS) TO AO1 TBC3 24 VAC TBC2 (OPTIONAL) To Unit Controller Ethernet Connection or Ethernet Switch E NGI NE E R ' S S E A L GND 3G TR3 120 VAC RED 3B TBA-4 WHITE TBA-2 2 (OPTIONAL) WHITE 22 23 +5 RED BLACK & SHIELD TBA23 CKT 1 SUC PSI OPTIONAL FIELD KEYPAD LCD TBA7 5 3 Bellimo WRV SENSOR M-4 REM RUN/STOP SENSOR M-3 SENSOR M-16 21 +5 TBA22 WHITE PWR MONITOR BLACK SHIELD OPT PWM CW OUT BLACK/ +5 SENSOR M-14 SHIELD +5 CMP1&2 ENABLE SENSOR M-2 FLOW-Field +5 +5 gnd DI-16 DI-15 DI-14 DI-13 DIGITAL INPUTS GND SI SENSOR 1 SENSOR M-13 WHITE +5 SENSOR M-15 TBA21 gnd WHITE BLACK SHIELD TO UNIT CONTOLLER KEYPAD/LCD CONNECTOR OPTIONAL WHITE TO TBC3 WRV SHIELD +12V GND SCL SDA +485 -485 CW IN +12v Gnd SCL SDA +485 -485 TO KEYPAD / DISPLAY SENSOR M-1 7 4 F2 2 RED C1 12 CCH 1 COMPRESSOR MOTOR T3 L3 L3 PDB1 2 T2 L2 C2 12 P.O. BOX 3066 LONGVIEW, TX 75606-3066 L3 T3 CCH 2 COMPRESSOR MOTOR COMPR C2 AUX 2 11 T1 L1 PANEL GROUND DISCONNECT (OPTIONAL) DRAWN BY: S MH BAR CHECKED BY: R80500011 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. B DWG. SIZE APP'D BY: S MH NAPPS JOB NO. R410A CGWR CHILLERS SCALE: NA DATE: 07/26/17 20 - 30 TON WATER-COOLED CHILLERS POWER/CONROL WIRING DIAGRAM TITLE: 1 T2 L2 L2 COMPR C1 AUX 1 11 T1 L1 L1 DSW1 Figure 9. Menu 8 F1 1 TBA6 TBA3 Electrical Schematics CGWR Power/Control Wiring Refer to name plate on control box door (inside) for electrical data and wiring diagram. Power/control wiring schematic for 20 to 30 ton, R-410A CGWR water-cooled chillers (OPTIONAL) NC 41 42 AMPS COMP 3 (CT 3) CKT 2 SUC PSI To Customer Interface or Communications Board or Optional Touchscreen - GND MCS IORS485 +12V + Termination DIGITAL ANALOG GND SI SENSOR 12 ETHERNET +5 ALARM NC Com NO WHITE BLACK SHIELD RELAY M-10 GND N L/L1 20 TBA20 TBA19 TBA18 TBA17 3 WHITE 3 BLACK IMPORTANT ADDRESS E NGI NE E R ' S S E A L # 1 2 3 4 5 6 7 8 THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. WHITE DIGITAL ANALOG Termination BY TRANSFORMER DIGITAL ANALOG CKT 2 SUC TMP 115v 19 18 17 SENSOR 8 S1 GND +5+12 +12 +12 SENSOR M-12 DIGITAL ANALOG Com NO WHITE (PUMP) CND ENBL RELAY M-9 NC CKT 1 SUC TMP Voltage Com NO NC GND SI SENSOR 11 DIGITAL ANALOG DIGITAL ANALOG DIGITAL ANALOG +5 DIGITAL ANALOG SPARE2-8 DIGITAL ANALOG BLACK SHIELD A3 GND A4 +5 GND SI A1 GND A2 SENSOR 16 ANALOG OUTPUTS SENSOR 2-8 DIGITAL ANALOG SPARE +5 GND SI SENSOR 15 SPARE2-7 DIGITAL ANALOG SENSOR M-11 +5 GND SI SENSOR 14 SENSOR 2-7 DIGITAL ANALOG GND SI SENSOR 10 +5 GND SI SENSOR 13 SPARE2-6 DIGITAL ANALOG +5 DIGITAL ANALOG SENSOR 2-6 SENSOR 7 S1 GND +5 SENSOR M-10 CKT 1 Comp 3 CONTACTOR DIGITAL ANALOG SPARE2-5 DIGITAL ANALOG SENSOR 2-5 SENSOR 6 S1 GND +5 DIGITAL ANALOG C3 WHITE SENSOR 5 S1 GND +5 SPARE RELAY M-8 C3 HOT GAS SOLENOID HGS 2 BLACK SHIELD SENSOR 4 S1 GND +5 WHITE GND SI SENSOR 9 DIGITAL ANALOG 9 5B LIQUID SOLENOID LLS 2 SPARE2-4 SENSOR 2-4 MTR MOD 2 SENSOR 2-3 SENSOR 3 S1 GND +5 BLACK & +5 SHIELD NCCom NO WHITE RELAY M-7 16A TBA13 13A TBA12 CKT2 Comp 2 CONTACTOR C2 HOT GAS SOLENOID HGS 1 LIQUID SOLENOID LLS 1 SENSOR 2-2 SPARE2-2 Y1 U + - SENSOR 2 S1 GND +5 AMPS COMP 2 (CT 2) GND SI SENSOR 8 DIGITAL ANALOG 16 3A 8A TBA11 7A TBA10 SENSOR 2-1 SPARE2-1 TBC-3 TBC-2 TBC-1 RED 1 DA T E WHITE 3C BLACK SHIELD WHITE BLACK SHIELD WHITE EXPANSION BOARD INTERFACE TO AO1 (OPTIONAL) 24 VAC TR3 120 VAC TBA-4 WHITE TBA-2 3B FU3 WHITE SENSOR 1 S1 GND +5 SENSOR M-9 CKT 2 DIS PSI +5 24 RED BLACK & SHIELD HGS 2 RELAY M-6 13 3A NC Com NO WHITE DIGITAL ANALOG GND SI SENSOR 7 LLS 2 RELAY M-5 12 11A 8 Com NO SENSOR M-8 WHITE +5 RED BLACK & SHIELD DIGITAL ANALOG C2 NC GND SI SENSOR 6 RELAY M-4 HGS 1 7 C1 TBA1 CKT1 Comp 1 CONTACTOR 3E TBA2 DIGITAL ANALOG SENSOR M-7 +5 RELAY M-3 LLS 1 3A LP2SW 3D +5 GND SI +5 GND SI SENSOR 11 SENSOR 12 WHITE RELAY M-2 6 TBA9 10 LP1SW RED ON/OFF 2 COM ALARM TBA3 TBA2 3G SPARE1-8 SENSOR 1-8 SPARE 1-7 SENSOR 1-7 SPARE 1-6 SENSOR 1-6 SPARE 1-5 SENSOR 1-5 SPARE 1-4 SENSOR 1-4 CORE TEMP SENSOR 1-3 TRGT RST Opt SENSOR 1-2 PWR MONITOROpt SENSOR 1-1 FU4 FU5 FU6 L1 L2 L3 PWM TR1 120 VAC R E V I S I ON FU2 FU1 COMPR 2 T2 C2 L2 12 T1 T3 MTR MOD 2 CKT 2 11 12 C1 AUX 1 CCH 1 CKT 1 T3 L3 N L 3G P.O. BOX 3066 LONGVIEW, TX 75606-3066 POWER IN +12V GND ?? DRAWN BY: S MH BAR CHECKED BY: R80500012 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. T3 B DWG. SIZE APP'D BY: S MH NAPPS JOB NO. R410A CGWR CHILLERS SCALE: 1.5"=12" DATE: 08/30/13 POWER/CONTROL WIRING SCHEMATIC 40 - 65 TON WATER-COOLED CHILLERS TITLE: (OPTIONAL TOUCHSCREEN POWER SOURCE) V+ V- ETHERNET 12 COMPRESSOR MOTOR COMPR 3 T2 L3 C3 AUX 3 CCH 3 11 T1 C3 L2 PANEL GROUND DISCONNECT (OPTIONAL) L1 L3 PDB1 DSW1 (OPTIONAL TOUCHSCREEN CONNECTIONS) TBC-2 To Unit Controller Ethernet Connection or Ethernet Switch TBC-1 COMPR 1 T2 C1 L2 L2 COMPRESSOR MOTOR L1 L1 L3 C2 AUX 2 CCH 2 11 COMPRESSOR MOTOR T1 L1 BLUE BLACK & SHIELD RELAY M-1 11A 10A HP2SW 11 TBA8 4 TBA6 3C 3 CONTROL PWR SWITCH YELLOW SENSOR M-6 NC Com NO GND SI SENSOR 5 DIGITAL ANALOG NC Com NO BLACK & SHIELD +5 GND SI SENSOR 4 DIGITAL ANALOG GND SI SENSOR 3 DIGITAL ANALOG NC Com NO C1 Com NO AMPS COMP 1 (CT 1) WHITE +5 RED BLACK & SHIELD DIGITAL ANALOG GND SI SENSOR 2 A-4 A-3 A-2 A-1 ANALOG OUTS KEYPAD LCD 5A TBA7 5 4A HP1SW To SI Board DIGITAL ANALOG SENSOR M-5 TBA24 WHITE 22 23 CKT 1 DIS PSI OPTIONAL FIELD 21 +5 GND SI SENSOR 10 SENSOR M-4 REM RUN/STOP TBA23 +5 GND SI SENSOR 9 +5 RED BLACK & SHIELD TBA22 DIGITAL ANALOG CKT 1 SUC PSI FLOW-Field DIGITAL ANALOG SENSOR M-3 SENSOR M-16 WHITE BLACK/ +5 SENSOR M-15 TBA21 DI-16DI-15 DI-14 DI-13 DIGITAL INPUTS GND SI SENSOR 1 gnd BLACK SHIELD SENSOR M-14 SHIELD gnd +5 CMP1&3 ENABLE +5 } WHITE (TO TBC3) SHIELD (TO TBC1) +12V GND SCL SDA +485 -485 WHITE BLACK SHIELD CMP2 ENABLE +5 OPTIONAL WRV +5 +5 TO KEYPAD / DISPLAY CW IN F3 3 RED 3 WHITE (OPTIONAL) SENSOR M-2 7 6 TBA3 Bellimo WRV #1 SENSOR M-1 F2 2 4 To SI Board (OPTIONAL) CW OUT 5 Menu 8 F1 1 TO UNIT CONTOLLER KEYPAD/LCD CONNECTOR Figure 10. } +12v Gnd SCL SDA +485 -485 Electrical Schematics Power/control wiring schematic for 40 to 65 ton, R-410A CGWR water-cooled chillers 120 VAC POWER IN LINE NEUT GND + - GND MCS I/O NC SENSOR M-13 WHITE UNIT CONTROLLER CG-SVX038A-EN CG-SVX038A-EN * TBC DSW1 * PDB1 1 2 3 4 1 2 3 4 IMPORTANT GND THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. TBC WRV C1 * ENGINEER'S SEAL C2 100-5563 600 600 VOLTS FOR 208-230V UNITS 3 1/2 3 1/2 AMPS # BY DATE FU1,2 FUSE SCHEDULE CC CC LITTELFUSE KLDR3 /1 2 TRANSFORMER SECONDARY FU3 CLASS FUSE TYPE LITTELFUSE KLDR3 1/2 LOCATION TRANSFORMER PRIMARY FU1, FU2 TRANSFORMER FUSE SCHEDULE CT2 DESIGNATION CT1 1 TR1 2 SW 2 2 RELAY M-2 3 3 4 4 RELAY M-3 5 5 6 6 RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 7 7 8 8 9 9 10 10 11 11 12 13 12 13 14 14 15 15 16 16 17 17 UNIT CONTROLLER REVISION FU3 1 1 RELAY M-4 RELAY M-1 FU4-6 1 - CPS On/Off 2 - CKT1 Enable 18 18 RELAY M-9 19 19 Voltage 20 20 115v RELAY M-10 21 21 22 22 23 23 24 24 GROUND LUG TERMINAL BLOCK TBA R 8 05 0002 0 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. B DWG. SIZE BAR P R ODUC T I ON NAPPS JOB NO. 20-30TON WATER-COOLED CHILLER 208-230V APP'D BY: P.O. BOX 3066 LONGVIEW, TX 75606-3066 ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS TOOGLE SWITCHES SW GND TBC SCROLL 410A WATER-COOLED CHILLER TBA PWM CIRCUIT FUSES - KTK OR EQ * * 120/24 VAC TRANSFORMER FOR WRV * TERMINAL BLOCK FOR WATER REGULATING VALVE CURRENT TRANSFORMER MODULES TR3 FU4,5,6 * COMMUNICATIONS MODULE CT1-CT2 COM UNIT CONTROLLER 208,240,480/120 VAC 250 VA TRANSFORMER UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ POWER DISTRIBUTION BLOCK PDB1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ TR1 SCALE: 1:1 DRAWN BY: CHECKED BY: SMH DATE: 10/2/13 SMH TITLE: CONTROL PANEL LAYOUT * PWM COM * UC COMPRESSOR CONTACTORS * DISCONNECT SWITCH * TR3 LEGEND * DIGITAL POWER MONITOR FU3 FU1, FU2 DSW1 C1-C2 PWM Figure 11. TBA TR3 * Electrical Schematics Control panel layout for 20 to 30 ton, 208V, R-410A CGWR water-cooled chillers 43 * TBC DSW1 * WRV 2 3 4 1 2 3 4 IMPORTANT GND C1 CC CC CLASS 3 1/2 1 1/2 100-5564 600 600 VOLTS FOR 460V UNITS AMPS # BY DA T E FU1,2 FUSE SCHEDULE TRANSFORMER SECONDARY FU3 E NGI NE E R ' S S E A L C2 FUSE TYPE LITTELFUSE KLDR1 1/2 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY FU1, FU2 1 TR3 * 2 TR1 3A THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. 1 DESIGNATION TRANSFORMER FUSE SCHEDULE CT2 SW 2 2 RELAY M-2 3 3 4 4 5 5 6 6 RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 7 7 8 8 9 9 10 10 11 11 12 13 12 13 14 14 15 15 16 16 17 17 UNIT CONTROLLER R E V I S I ON FU3 1 1 1 - CPS On/Off 2 - CKT1 Enable RELAY M-1 TBA PDB1 * CT1 RELAY M-3 44 RELAY M-4 FU4-6 18 18 RELAY M-9 19 19 Voltage 20 20 115v RELAY M-10 21 21 22 22 23 23 24 24 UNIT CONTROLLER CURRENT TRANSFORMER MODULES * COMMUNICATIONS MODULE GROUND LUG TERMINAL BLOCK TBA R 8 05 0002 1 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. P R ODUC T I ON NAPPS JOB NO. B DWG. SIZE BAR APP'D BY: P.O. BOX 3066 LONGVIEW, TX 75606-3066 ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS TOOGLE SWITCH SW GND FU4,5,6 TR3 * 120/24 VAC TRANSFORMER FOR WRV * PWM CIRCUIT FUSES - KTK OR EQ TBC * TERMINAL BLOCK FOR WATER REGULATING VALVE CT1-CT2 COM UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ POWER DISTRIBUTION BLOCK PDB1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ 208,240,480/120 VAC 250 VA TRANSFORMER TR1 CGWR SCROLL 410A WATER-COOLED CHILLER TBA COMPRESSOR CONTACTORS * DISCONNECT SWITCH SCALE: NA DRAWN BY: CHECKED BY: SMH DATE: 8/11/17 SMH CONTROL PANEL LAYOUT TITLE: 20 - 30 TON WATER-COOLED CHILLER 460V * PWM COM * UC LEGEND * DIGITAL POWER MONITOR FU3 FU1, FU2 DSW1 C1-C2 PWM Electrical Schematics Figure 12. Control panel layout for 20 to 30 ton, 460V, R-410A CGWR water-cooled chillers CG-SVX038A-EN CG-SVX038A-EN * TBC DSW1 * 1 2 3 4 1 2 3 4 IMPORTANT GND THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. TBC WRV C1 FU3 E NGI NE E R ' S S E A L C2 CC FU1, FU2 3 1/2 1 1/4 100-5564A 600 600 VOLTS FOR 575V UNITS AMPS # BY 1 TR3 * DA T E FU1,2 FUSE SCHEDULE CC CLASS FUSE TYPE LITTELFUSE KLDR1 1/4 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY TRANSFORMER SECONDARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT2 TR1 2 SW 2 2 RELAY M-2 3 3 4 4 RELAY M-3 5 5 6 6 RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 7 7 8 8 9 9 10 10 11 11 12 13 12 13 14 14 15 15 16 16 17 17 UNIT CONTROLLER R E V I S I ON FU3 1 1 1 - CPS On/Off 2 - CKT1 Enable RELAY M-1 TBA PDB1 * CT1 RELAY M-4 FU4-6 18 18 RELAY M-9 19 19 Voltage 20 20 115v RELAY M-10 21 21 22 22 23 23 24 24 COM CURRENT TRANSFORMER MODULES * COMMUNICATIONS MODULE GROUND LUG TERMINAL BLOCK TBA P.O. BOX 3066 LONGVIEW, TX 75606-3066 R 8 05 0002 2 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. P R ODUC T I ON NAPPS JOB NO. B DWG. SIZE APP'D BY: ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS TOOGLE SWITCH SW GND TR3 * 120/24 VAC TRANSFORMER FOR WRV FU4,5,6 * PWM CIRCUIT FUSES - KTK OR EQ TBC * TERMINAL BLOCK FOR WATER REGULATING VALVE CT1-CT2 UNIT CONTROLLER 600 VAC 250 VA TRANSFORMER UC POWER DISTRIBUTION BLOCK TR1 TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ PDB1 FU3 * DISCONNECT SWITCH SCROLL 410A WATER-COOLED CHILLER TBA DSW1 FU1, FU2 LEGEND COMPRESSOR CONTACTORS * DIGITAL POWER MONITOR SCALE: 1:1 DRAWN BY: CHECKED BY: DATE: 10/25/2011 PMK TITLE: CONTROL PANEL LAYOUT 20-30 TON WATER-COOLED CHILLER 575V * PWM COM * UC PWM C1-C2 Electrical Schematics Figure 13. Control panel layout for 20 to 30 ton, 575V, R-410A CGWR water-cooled chillers 45 * TBC DSW1 * TBC WRV PDB1 1 2 3 4 1 2 3 4 IMPORTANT C1 THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. GND * C2 E NGI NE E R ' S S E A L C3 CT1 # BY FUSE SCHEDULE CC LITTELFUSE KLDR3 /1 2 TRANSFORMER SECONDARY FU3 10 0 - 5 5 6 3 3 1/2 600 600 CT2 DA T E VOLTS F O R 2 0 8 - 2 3 0 V U NITS 3 1/2 AMPS TR3 * CC FU1, FU2 CLASS FUSE TYPE LITTELFUSE KLDR3 1/2 LOCATION TRANSFORMER PRIMARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT3 FU1,2 PWM * TR1 1 2 TBA 1 1 2 2 R E V I S I ON FU3 3 3 3 4 4 5 5 6 6 7 7 COM * RELAY M-2 FU4-6 8 8 RELAY M-3 RELAY M-1 46 9 9 10 10 RELAY M-4 1 - CPS On/Off SW 2 - CKT1 Enable 3 - CKT2 Enable RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 11 11 12 13 12 13 14 14 15 15 16 16 17 17 18 18 19 19 UNIT CONTROLLER 20 20 RELAY M-9 21 21 Voltage 22 22 RELAY M-10 115v 24 24 EXPANSION BOARD SI 16-A04 EXP1 L I MI T R ON K T K 1 1 3 1/2 3 1/2 AMPS P.O. BOX 3066 LONGVIEW, TX 75606-3066 CC CC CLASS SCROLL 410A WATER-COOLED CHILLER DIGITAL POWER MONITOR * SECONDARY TRANSFORMER FU3 FUSE TYPE LITTELFUSE 1 KLDR3 2 LITTELFUSE 1 KLDR3 2 FOR 208-230V UNITS 1. ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS. FUSE SCHEDULE LOCATION GROUND LUG NOTES: GND FU4,5,6 B 6 00 600 600 VOLTS * TERMINAL BLOCK FOR WATER REGULATING VALVE * PWM CIRCUIT FUSES - KTK OR EQ TERMINAL BLOCK TBC TOGGLE SWITCHES SW TBA PRIMARY TRANSFORMER FU4, FU5, FU6 * CURRENT TRANSFORMER MODULES COMMUNICATIONS MODULE 120/24 VAC TRANSFORMER FOR WRV DIGITAL POWER MONITOR TR3 * PWM * CT1-CT3 FU1, FU2 DESIGNATION TBA EXP1 POWER DISTRIBUTION BLOCK COM UNIT CONTROLLER 208,240,480/120 VAC 250 VA TRANSFORMER PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ DISCONNECT SWITCH FU3 * LEGEND COMPRESSOR CONTACTORS R 8 05 0002 3 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. P R ODUC T I ON NAPPS JOB NO. APP'D BY: SCALE: 1:1 DRAWN BY: CHECKED BY: DATE: 9/26/13 SMH SMH BAR DWG. SIZE TITLE: CONTROL PANEL LAYOUT 208/230V 40 - 65 TON WATER-COOLED CHILLER 23 23 230V UC * FU1, FU2 DSW1 C1-C3 Electrical Schematics Figure 14. Control panel layout for 40 to 65 ton, 208V, R-410A CGWR water-cooled chillers CG-SVX038A-EN * TBC WRV 1 2 3 4 1 2 3 4 IMPORTANT THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. GND * FU4-6 C1 C2 ENGINEER'S SEAL C3 CC CC FU1, FU2 FU3 # BY 3 1/ 2 1 1/2 10 0 - 5 5 6 4 600 600 VOLTS F O R 4 6 0 V U NITS AMPS DATE TR3 * CLASS FUSE TYPE LITTELFUSE KLDR1 1/2 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY TRANSFORMER SECONDARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT3 FUSE SCHEDULE CT1 FU1,2 PWM * TR1 1 2 TBA 1 1 2 2 3 3 REVISION FU3 3 4 4 5 5 6 6 7 7 COM * RELAY M-2 CT2 8 8 RELAY M-3 CG-SVX038A-EN TBC DSW1 * PDB1 9 9 10 10 RELAY M-4 RELAY M-1 1 - CPS On/Off SW 2 - CKT1 Enable 3 - CKT2 Enable RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 11 11 12 13 12 13 14 14 15 15 16 16 17 17 18 18 19 19 UNIT CONTROLLER 20 20 RELAY M-9 21 21 Voltage 22 22 RELAY M-10 24 24 CURRENT TRANSFORMER MODULES COMMUNICATIONS MODULE TBC LITTELFUSE 1 KLDR3 2 L I MI T R ON K T K 1 SECONDARY TRANSFORMER DIGITAL POWER MONITOR * LITTELFUSE KLDR1 FUSE TYPE FUSE SCHEDULE PRIMARY TRANSFORMER LOCATION CC CC CLASS 1 3 1/2 1 1/2 AMPS FOR 460V UNITS 6 00 600 600 VOLTS B DWG. SIZE APP'D BY: BAR P.O. BOX 3066 LONGVIEW, TX 75606-3066 2 1 1. ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS. GROUND LUG * PWM CIRCUIT FUSES - KTK OR EQ NOTES: GND FU4,5,6 TERMINAL BLOCK FOR WATER REGULATING VALVE TERMINAL BLOCK SW TBA * EXPANSION BOARD SI 16-A04 TOGGLE SWITCHES EXP1 TR3 * 120/24 VAC TRANSFORMER FOR WRV PWM * DIGITAL POWER MONITOR CT1-CT3 CGWR SCROLL 410A WATER-COOLED CHILLER FU4, FU5, FU6 * FU3 FU1, FU2 DESIGNATION TBA EXP1 POWER DISTRIBUTION BLOCK COM UNIT CONTROLLER 208,240,480/120 VAC 250 VA TRANSFORMER PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ DISCONNECT SWITCH FU3 * LEGEND COMPRESSOR CONTACTORS SCALE: 1:1 DRAWN BY: CHECKED BY: DATE: 9/27/13 SMH SMH TITLE: CONTROL PANEL LAYOUT 115v R 8 05 0002 4 0 1 OF 1 P R ODUC T I ON 40-65 TON WATER-COOLED CHILLER 460V DRAWING NUMBER REV.SHEET NO. NAPPS JOB NO. 23 23 230V UC * FU1, FU2 DSW1 C1-C3 Electrical Schematics Figure 15. Control panel layout for 40 to 65 ton, 460V, R-410A CGWR water-cooled chillers 47 * TBC DSW1 * TBC WRV PDB1 1 2 3 4 1 2 3 4 IMPORTANT THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. GND * FU4-6 C1 C2 E NGI NE E R ' S S E A L C3 FUSE TYPE LITTELFUSE KLDR1 1/4 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY TRANSFORMER SECONDARY DESIGNATION FU1, FU2 FU3 TRANSFORMER FUSE SCHEDULE # BY 3 1/ 2 1 1/4 10 0 - 5 5 6 4 600 600 FU1,2 PWM * TR1 1 2 TBA R E V I S I ON FU3 3 1 1 2 2 3 3 4 4 5 5 6 6 7 7 COM * RELAY M-2 CT2 DA T E VOLTS F O R 4 6 0 V U NITS AMPS TR3 * CC CC CLASS CT3 FUSE SCHEDULE CT1 8 8 RELAY M-3 RELAY M-1 48 9 9 10 10 RELAY M-4 1 - CPS On/Off SW 2 - CKT1 Enable 3 - CKT2 Enable RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 11 11 12 13 12 13 14 14 15 15 16 16 17 17 18 18 19 19 UNIT CONTROLLER 20 20 RELAY M-9 21 21 Voltage 22 22 RELAY M-10 115v 24 24 DIGITAL POWER MONITOR EXPANSION BOARD SI 16-A04 EXP1 TOGGLE SWITCHES TERMINAL BLOCK GND TBC P.O. BOX 3066 LONGVIEW, TX 75606-3066 1. ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS. NOTES: GROUND LUG B * TERMINAL BLOCK FOR WATER REGULATING VALVE FU4,5,6 * PWM CIRCUIT FUSES - KTK OR EQ SW TBA 120/24 VAC TRANSFORMER FOR WRV CURRENT TRANSFORMER MODULES COMMUNICATIONS MODULE TR3 * PWM * CT1-CT3 UNIT CONTROLLER POWER DISTRIBUTION BLOCK PDB1 COM * 600 VAC 250 VA TRANSFORMER TR1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ FU3 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ DISCONNECT SWITCH SCROLL 410A WATER-COOLED CHILLER TBA EXP1 LEGEND COMPRESSOR CONTACTORS R 8 05 0002 5 0 1 OF 1 P R ODUC T I ON APP'D BY: SCALE: 1:1 DRAWN BY: CHECKED BY: DATE: 9/27/13 SMH SMH BAR DWG. SIZE TITLE: CONTROL PANEL LAYOUT 40-65 TON WATER-COOLED CHILLER 575V DRAWING NUMBER REV.SHEET NO. NAPPS JOB NO. 23 23 230V UC * FU1, FU2 DSW1 C1-C3 Electrical Schematics Figure 16. Control panel layout for 40 to 65 ton, 575V, R-410A CGWR water-cooled chillers CG-SVX038A-EN Electrical Schematics CCAR Compressor Chillers CCAR Field Wiring Figure 17. Field wiring diagram for 20 to 30 ton, R-410A CCAR compressor chillers Control Panel Representation L1 L2 L3 PDB1 A-1 GND A-2 UNIT CONTROLLER A-1 GND A-2 6 Optional: Disconnect (Factory Installed) PANEL GROUND Optional: Damper Control 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TBA DSW1 23 24 Condensing Unit Control Power 4 Condensing Unit Fan 1 Condensing Unit Fan 2 WARNING Hazardous voltage! Disconnect all electrical power including remote disconnects before servicing unit. Follow proper lockout/ tagout procedures to ensure power cannot be inadvertently energized. Failure to do so c an cause death or serious injury. Condensing Unit Fan 3 Optional : Alarm Dry Contacts 5 REQUIRED: Flow Switch (flow proving device) Optional: Remote Run/Stop Interface Notes: CAUTION Use copper conductors only! Unit terminals are not designed to accept other type conductors. Failure to use copper conductors may cause equipment damage. 1. 2. 3. 4 4. 5 5. CAUTION Do not energize the unit until checkout and start-up procedures have been completed. 6. 6 7. All three-phase motors supplied with the unit are protected under primary single-phase failure conditions. All customer control-circuit wiring must have a minimum rating of 150V. All field wiring must be in accordance with applicable local codes. Line voltage options. Single or dual source power may be speci fied. Drawing covers single source power only. All field wiring must be in accordance with National Electric Code and State & Local requirements. (Required) Factory supplied or approved alternate field installed flow proving device connection. (Optional) Damper control option. Refer to operation and maintenance manual for additional information. This point intended to operate a low ambient damper on a remote air-cooled condenser. Wiring to be 2-wire shielded cable between outdoor unit and Trane indoor chiller. If installing with a Trane CAUJ air-cooled condenser, more specific field wiring instructions can be found in the operations and maintenance manual. NAME DATE DRAWN SMH 3/22/17 CHECKED BAR 3/22/17 ENG APPR. MFG APPR. Q.A. COMMENTS: CCAR 20-30 Ton Field Wiring Diagram SIZE DWG. NO. REV. A Field Wiring Single Circuit CCAR 0 SCALE:1:5 CG-SVX038A-EN WEIGHT: SHEET 1 OF 1 49 Electrical Schematics Figure 18. Field wiring diagram for 40 to 65 ton, R-410A CCAR compressor chillers Control Panel Representation L1 L2 L3 PDB1 A-1 GND A-2 UNIT CONTROLLER A-1 GND A-2 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 4 Optional: Damper Control 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TBA PANEL GROUND 6 Optional: Disconnect (Factory Installed) TBD DSW1 23 24 Circuit 2 Fan 3 Circuit 2 Fan 2 Circuit 2 Fan 1 Optional: Alarm Dry Contacts Circuit 1 Fan 3 Circuit 1 Fan 2 5 Circuit 1 Fan 1 Condensing Unit Control Power WARNING Hazardous voltage! Disconnect all electrical power including remote disconnects before servicing unit. Follow proper lockout/ tagout procedures to ensure power cannot be inadvertently energized. Failure to do so can cause death or serious injury. CAUTION Use copper conductors only! Unit terminals are not designed to accept other type conductors. Failure to use copper conductors may cause equipment damage. CAUTION Do not energize the unit until checkout and start-up procedures have been completed. REQUIRED: Flow Switch (flow proving device) Optional: Remote Run/Stop Interface Notes: 1. 2. 3. 4. 4 5. 5 6. 6 7. All three-phase motors supplied with the unit are protected under primary single-phase failure conditions. All customer control-circuit wiring must have a minimum rating of 150V. All field wiring must be in accordance with applicable local codes. Line voltage options. Single or dual source power may be specified. Drawing covers single source power only. All field wiring must be in accordance with National Electric Code and State & Local requirements. (Required) Factory supplied or appr oved alternate field installed flow proving device connection. (Optional) Damper control option. Refer to operation and maintenance manual for additional information. This point intended to operate low ambient dampers on a remote air-cooled condenser, (1) damper per AO. Wiring to be 2-wire shielded cable between outdoor unit and Trane indoor chiller. If installing with a Trane CAUJ air-cooled condenser, more specific field wiring instructions can be found in the operations and maintenance manual. NAME DATE DRAWN SMH 3/23/17 CHECKED BAR 3/23/17 CCAR 40-65 Ton Field Wiring Diagram ENG APPR. MFG APPR. Q.A. COMMENTS: REV. SIZE DWG. NO. A Dual Circuit CCAR Field Wiring SCALE:1:5 50 WEIGHT: 0 SHEET 1 OF 1 CG-SVX038A-EN 5 Menu 8 F1 1 F2 2 6 F3 3 CG-SVX038A-EN (Shield tied at this end) MCS IORS485 +12V Termination + - GND DIGITAL ANALOG GND SI SENSOR 12 ETHERNET +5 UNIT CONTROLLER To Optional Exp Board Comm to SI16 or eq WHITE BLACK SHIELD DIGITAL ANALOG GND SI SENSOR 11 115v Voltage ALARM RELAY M-10 Com NO NC To Customer Interface or Communications Board or Optional Touchscreen CORE TEMP SENSOR M-12 +5 18 GND N L/L1 20 19 TBA19 TBA20 3 IMPORTANT WHITE Comp 2 CONTACTOR C2 TBA5 TBA4 TBA3 THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. TBA18 TBA17 17 15B TBA16 15A TBA15 Com NO WHITE FAN 3 RELAY M-9 FAN 2 RELAY M-8 FAN 1 Comp 1 CONTACTOR C1 TBA1 TBA2 HOT GAS SOLENOID HGS 1 16 9 5B 3A 8A 3D LIQUID SOLENOID LLS 1 15 NC DIGITAL ANALOG GND SI SENSOR 10 DIGITAL ANALOG GND SI SENSOR 9 DIGITAL ANALOG RELAY M-7 C2 RELAY M-6 SPARE RELAY M-5 SPARE 8 TBA11 7A TBA10 LP1SW 3A 4 NC Com NO +5 +5 GND SI SENSOR 8 DIGITAL ANALOG GND SI SENSOR 7 DIGITAL ANALOG RELAY M-4 HGS 1 7 6 5A TBA7 5 TBA6 4A HP1SW NC Com NO BLACK SHIELD 24 +5 +5 DIGITAL ANALOG GND SI SENSOR 6 RELAY M-3 LLS 1 NC Com NO CKT 1 SUC TMP WHITE BLACK & SHIELD +5 GND SI SENSOR 5 RELAY M-2 Com NO SENSOR M-11 AMPS COMP 2 (CT 2) WHITE +5 RELAY M-1 NC SENSOR M-6 WHITE NC Com NO BLACK & SHIELD DIGITAL ANALOG GND SI SENSOR 4 DIGITAL ANALOG NC Com NO C1 NC Com NO AMPS COMP 1 (CT 1) +5 RED BLACK & SHIELD GND SI SENSOR 3 DIGITAL ANALOG GND SI SENSOR 2 DIGITAL ANALOG KEYPAD LCD Com NO SENSOR M-5 TBA24 WHITE 22 23 CKT 1 DIS PSI OPTIONAL FIELD TBA23 SENSOR M-4 REM RUN/STOP 21 CKT 1 SUC PSI TBA22 +5 RED BLACK & SHIELD FLOW-Field WHITE BLACK/ SENSOR M-3 PWR MONITOR +5 OPT PWM BLACK SHIELD gnd DI-16DI-15 DI-14 DI-13 A-4 A-3 A-2 A-1 DIGITAL INPUTS ANALOG OUTS GND SI SENSOR 1 SENSOR M-13 WHITE CW OUT SENSOR M-16 gnd SENSOR M-2 CMP1&2 ENABLE +5 SENSOR M-14 SHIELD +5 SHIELD +5 SENSOR M-15 TBA21 +5 +5 OPTIONAL DAMPER CONTROL +12V GND SCL SDA +485 -485 WHITE BLACK SHIELD TO UNIT CONTOLLER KEYPAD/LCD CONNECTOR TO KEYPAD / DISPLAY CW IN SENSOR M-1 7 4 +12v Gnd SCL SDA +485 -485 3 3G 3 3G RED 1 N ETHERNET L BY DA T E (OPTIONAL TOUCHSCREEN POWER SOURCE) # 120 VAC TR1 POWER IN +12V GND ?? L1 L2 L3 PWM FU2 FU1 R E V I S I ON FU4 FU5 FU6 (OPTIONAL TOUCHSCREEN CONNECTIONS) FU3 V+ V- 2 To Unit Controller Ethernet Connection or Ethernet Switch E NGI NE E R ' S S E A L GND RED WHITE 2 T2 L2 C2 12 CCH 1 12 DRAWN BY: S MH BAR CHECKED BY: 1 OF 1 REV.SHEET NO. R80500013 0 DRAWING NUMBER NAPPS JOB NO. B DWG. SIZE APP'D BY: S MH R410 CCAR COMPRESSOR CHILLERS SCALE: DATE: 08/03/17 T3 L3 CCH 2 P.O. BOX 3066 LONGVIEW, TX 75606-3066 C2 AUX 2 POWER/CONTROL WIRING SCHEMATIC 20 - 30 TON COMPRESSOR CHILLER TITLE: 11 T1 L1 PANEL GROUND COMPRESSOR MOTOR PDB1 COMPRESSOR MOTOR 1 T3 L3 L3 COMPR C1 AUX 1 11 C1 T2 L2 L2 DISCONNECT (OPTIONAL) COMPR T1 L1 L1 DSW1 Electrical Schematics CCAR Power/Control Wiring Refer to name plate on control box door (inside) for electrical data and wiring diagram. Figure 19. Power/control wiring schematic for 20 to 30 ton, R-410A CCAR compressor chillers (OPTIONAL) NC 51 WHITE (CT 3) CKT 2 SUC PSI F1 Menu 8 5 F2 2 7 4 6 F3 3 - GND MCS IORS485 +12V + Termination DIGITAL ANALOG GND SI SENSOR 12 ETHERNET +5 DIGITAL ANALOG GND SI SENSOR 11 DIGITAL ANALOG 115v Voltage RELAY M-2 RELAY M-3 RELAY M-4 ALARM RELAY M-10 SPARE RELAY M-9 SPARE RELAY M-8 C3 RELAY M-7 HGS 2 RELAY M-6 LLS 2 RELAY M-5 C2 HGS 1 LLS 1 C1 RELAY M-1 GND N L/L1 20 19 18 17 9 5B 16 13 12 11B 8 7 6 5A TBA7 TBA20 TBA19 TBA18 3A TBA9 4 16A TBA13 13A TBA12 8A TBA11 3A 10 3D C1 TBA1 CKT 1 Comp 1 CONTACTOR 3E TBA2 3 WHITE CKT1 Comp 3 CONTACTOR C3 HOT GAS SOLENOID HGS 2 LIQUID SOLENOID LLS 2 CKT2 Comp 2 CONTACTOR C2 HOT GAS SOLENOID HGS 1 LIQUID SOLENOID LLS 1 LP2SW LP1SW TBA6 TBA8 7A TBA10 10A HP2SW 11 TBA17 11A 5 4A HP1SW To SI Board 3C 3 TBA3 RED 3 WHITE SPARE2-8 SENSOR 2-8 SPARE2-7 SENSOR 2-7 SPARE2-6 SENSOR 2-6 SPARE2-5 SENSOR 2-5 SPARE2-4 SENSOR 2-4 MTR MOD 2 SENSOR 2-3 SPARE2-2 SENSOR 2-2 SPARE2-1 SENSOR 2-1 WHITE BLACK WHITE BLACK SHIELD 3B TBA1 THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. IMPORTANT TBA5 WHITE 1 +12v Gnd SCL SDA +485 -485 WHITE BLACK SHIELD +5 DIGITAL ANALOG GND SI SENSOR 10 A-4 A-3 A-2 A-1 ANALOG OUTS NCCom NO To Customer Interface or Communications Board or Optional Touchscreen CKT 2 SUC TMP SENSOR M-12 WHITE BLACK SHIELD +5 GND SI SENSOR 9 DIGITAL ANALOG GND SI SENSOR 8 DIGITAL ANALOG GND SI SENSOR 7 DIGITAL ANALOG GND SI SENSOR 6 DIGITAL ANALOG GND SI SENSOR 5 DIGITAL ANALOG GND SI SENSOR 4 DIGITAL ANALOG GND SI SENSOR 3 DIGITAL ANALOG GND SI SENSOR 2 DIGITAL ANALOG } } KEYPAD LCD Com NO CKT 1 SUC TMP SENSOR M-11 WHITE BLACK & +5 SHIELD WHITE +5 +5 DI-16 DI-15 DI-14 DI-13 DIGITAL INPUTS GND SI SENSOR 1 +5 NC SPARE SENSOR M-10 (CT 2) AMPS COMP 2 SENSOR M-9 CKT 2 DIS PSI WHITE RED BLACK & SHIELD 24 SENSOR M-8 +5 +5 +5 RED BLACK & SHIELD WHITE BLACK & SHIELD (CT 1) BLACK & SHIELD WHITE +5 RED BLACK & SHIELD WHITE AMPS COMP 3 SENSOR M-7 +5 +5 +5 RED BLACK & SHIELD WHITE BLACK SHIELD WHITE BLACK SHIELD SENSOR M-6 AMPS COMP 1 SENSOR M-5 CKT 1 DIS PSI SENSOR M-4 CKT 1 SUC PSI SENSOR M-3 CW OUT SENSOR M-2 CW IN SENSOR M-1 TBA24 +5 +5 22 23 NC Com NO ADDRESS 21 NC Com NO Termination 3 ADDRESS ON/OFF 2 CONTROL PWR SWITCH 30 FU3 # BLACK SHIELD WHITE RED 1 BY ALARM TBA3 SPARE1-8 3G SENSOR 1-8 WHITE DA T E TR3 11 12 RO10 28 TBD4 CKT1 FAN3 31 CKT2 FAN2 TBD7 To Unit Controller Ethernet Connection or Ethernet Switch 24 VAC 32 27 TBD3 CKT1 FAN2 R E V I S I ON 25 TBD1 CKT2 FAN3 TBD8 TBA-4 WHITE 120 VAC MTR MOD 2 26 3 T2 C3 L2 11 12 C1 AUX 1 CCH 1 12 V+ V- N L 3G POWER IN +12V GND ?? P.O. BOX 3066 LONGVIEW,TX 75606-3066 (OPTIONAL TOUCHSCREEN POWER SOURCE) ETHERNET DRAWN BY: S MH BAR CHECKED BY: 1 OF 1 REV.SHEET NO. R80500014 0 DRAWING NUMBER NAPPS JOB NO. B DWG. SIZE APP'D BY: S MH R410 CCAR COMPRESSOR CHILLERS SCALE: DATE: 07 / 2 7 / 17 T3 L3 C3 AUX 3 CCH 3 (OPTIONAL TOUCHSCREEN CONNECTIONS) POWER/CONTROL WIRING SCHEMATIC 40 - 65 TON COMPRESSOR CHILLER TITLE: TBD2 CKT1 FAN1 11 T1 L1 COMPR CKT 1 T3 L3 PANEL GROUND COMPRESSOR MOTOR 1 T2 C1 L3 PDB1 DISCONNECT (OPTIONAL) COMPR T1 T3 L2 L2 DSW1 COMPRESSOR MOTOR L1 L1 L3 CKT 2 RED 3H COMPR 2 T2 C2 L2 COMPRESSOR MOTOR T1 L1 C2 AUX 2 CCH 2 TBA-2 (OPTIONAL) FU2 FU1 SPARE 1-7 RO 8 SENSOR 1-7 SPARE 1-6 SENSOR 1-6 SPARE 1-5 SENSOR 1-5 SPARE 1-4 SENSOR 1-4 CORE TEMP SENSOR 1-3 Optional TRGT RST SENSOR 1-2 Optional PWR MONITOR SENSOR 1-1 TBA2 COM TR1 120 VAC 3C BLACK SHIELD WHITE WHITE TRANSFORMER TBD6 CKT2 FAN1 E NGI NE E R ' S S E A L TRANSFORMER OPTIONAL FIELD TBA23 RO 10 TBA22 NC Com NO RO 5 FLOW-Field Com NO A3 GND A4 RO 3 BLACK/ NC RO 7 SENSOR M-15 TBA21 NC Com NO ANALOG OUTPUTS RO 2 CMP2 ENABLE NC Com NO A1 GND A2 RO 6 SENSOR M-14 SHIELD +5 GND SI +5 GND SI +5 GND SI +5 GND SI +5 GND SI +5 GND SI SENSOR 11 SENSOR 12 SENSOR 13 SENSOR 14 SENSOR 15 SENSOR 16 LINE NEU L1 L2GND CMP1&3 ENABLE NC Com NO DIGITAL ANALOG 1 2 3 4 5 6 7 8 RO 1 EXPANSIONBOARDINTERFACE 115V gnd Com NO DIGITAL ANALOG 1 2 3 4 5 6 7 8 REM RUN/STOP gnd DIGITAL ANALOG + - GND MCS I/O SENSOR M-16 SHIELD DIGITAL ANALOG DIGITAL ANALOG Termination OPTIONAL DAMPER CONTROL +12V GND SCL SDA +485 -485 DIGITAL ANALOG ANALOG COM NO NC +5 GND SI SENSOR 10 DIGITAL ANALOG DIGITAL COM NO NC +5 GND SI SENSOR 9 DIGITAL ANALOG DIGITAL ANALOG COM NO NC DIGITAL ANALOG DIGITAL ANALOG NC NO COM DIGITAL ANALOG DIGITAL ANALOG NC NO COM TO KEYPAD / DISPLAY DIGITAL ANALOG COM NO NC DIGITAL ANALOG 120 VAC POWER IN LINE NEUT GND COM NO NC DIGITAL ANALOG SENSOR 5 SENSOR 6 SENSOR 7 SENSOR 8 SENSOR 4 SENSOR 3 SI GND +5SI GND +5 SI GND +5 SI GND +5 SI GND +5SI GND +5 +12 +12 +12 RO 9 L1 L2 L3 RO 4 FU4 FU5 FU6 NC NO COM SENSOR 2 SI GND +5 BLUE JUMPERS PWM NC NO COM SENSOR 1 SI GND +5 YELLOW NC NO COM 52 To SI Board Electrical Schematics Figure 20. Power/control wiring schematic for 40 to 65 ton, R-410A CCAR compressor chillers + - GND MCS I/O NC SENSOR M-13 WHITE UNIT CONTROLLER TO UNIT CONTROLLER KEYPAD LCD CONNECTOR CG-SVX038A-EN Electrical Schematics Figure 21. Power schematic, CAUJ condenser control circuit modification: fan cycling control by CCAR compressor chillers A B D 1TB2-1 1TB3-4 A 63 34 E 1TB3-5 64 C E C A E 1TB3-6 65 1TB3-9 76 1TB3-10 77 C 1TB3-11 78 F CG-SVX038A-EN G 53 Electrical Schematics Figure 22. Instructions — CAUJ condenser control circuit modification: fan cycling control by CCAR compressor chillers Trane CAUJ Condenser Control Wiring Modification Fan Cycling Control by Trane CCAR Compressor Chillers FOR CONTROL OF 2 FAN CONDENSER: COMPLETE Initial/Date Step Reference 1 A Connect 1TB2-1 to TBA 15 at Trane Chiller. 2 B Remove wire 64E. Connect 1TB3-5 to TBA 16 at Trane Chiller. This is the first fan on and last fan off. 3 D Remove wire 63A. Connect 1TB3-4 to TBA 17 at Trane Chiller. This is the second fan on and first fan off. The installed pressure switch will not be used. Instructions Circle FOR CONTROL OF 3 FAN CONDENSER: Step Reference Circle 1 A 2 B 3 C 4 D COMPLETE Initial/Date Instructions Connect 1TB2-1 to TBA 15 at Trane Chiller. Remove wire 64E. Connect 1TB3-5 to TBA 16 at Trane Chiller. This is the first fan on and last fan off. Remove wire 65C and/or the jumper installed. Connect 1TB3-6 to TBA 17 at Trane Chiller. Ambient t-stat will not be used. This is the second fan on and second fan off. Remove wire 63A. Connect 1TB3-4 to TBA 18 at Trane Chiller. This is the last fan on and first fan off. The installed pressure switch will not be used. FOR CONTROL OF 4 FAN CONDENSER: Step Reference Circle COMPLETE Initial/Date Instructions 1 A Connect 1TB2-1 to TBD 1 at Trane Chiller. 2 B Remove wire 64E. Connect 1TB3-5 to TBD 2 at Trane Chiller. This is the first fan on and last fan off. 3 D Remove wire 63A. Connect 1TB3-4 to TBD 3 at Trane Chiller. This is the last fan on and first fan off. The installed pressure switch will not be used. Remove wire 77E. Connect 1TB3-10 to TBD 6 at Trane Chiller.This is the first fan on and last fan off. 4 E 5 G Remove wire 76A. Connect 1TB3-9 to TBD 7 at Trane Chiller. This is the last fan on and first fan off. The installed pressure switch will not be used. FOR CONTROL OF 6 FAN CONDENSER: Step Reference Circle 1 A 2 B 3 C 4 D 5 E 6 F 7 G COMPLETE Initial/Date Instructions Connect 1TB2-1 to TBD 1 at Trane Chiller. Remove wire 64E. Connect 1TB3-5 to TBD 2 at Trane Chiller. This is the first fan on and last fan off. Remove wire 65C and/or the jumper installed. Connect 1TB3-6 to TBD 3 at Trane Chiller. Ambient t-stat will not be used. This is the second fan on and second fan off. Remove wire 63A. Connect 1TB3-4 to TBD 4 at Trane Chiller. This is the last fan on and first fan off. The installed pressure switch will not be used. Remove wire 77E. Connect 1TB3-10 to TBD 6 at Trane Chiller. This is the first fan on and last fan off. Remove wire 78C and/or the jumper installed. Connect 1TB3-11 to TBD 7 at Trane Chiller. Ambient t-stat will not be used. This is the second fan on and second fan off. Remove wire 76A. Connect 1TB3-9 to TBD 8 at Trane Chiller. This is the last fan on and first fan off. The installed pressure switch will not be used. NOTES: All CCAR/CAUJ applications require that the CCAR Compressor Chiller control the condenser fan cycling. For Fan Cycling Control - One control wire for each condenser fan plus a common must be run from the CCAR Compressor Chiller to the CAUJ condenser. CCAR units are designed for operation down to a minimum of 40°F ambient. PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF TRANE. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF TRANE IS PROHIBITED. DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL MATERIAL DATE LAH 09/19/13 CHECKED SMH 09/19/13 ENG APPR. EGN 09/19/13 MFG APPR. BAR 09/19/13 Q.A. COMMENTS: FINISH P.O. BOX 3066 LONGVIEW, TX 75606-3066 CAUJ Condenser Control Wiring Modification: Fan Cycling Control by CCAR Compressor Chillers SIZE DO NOT SCALE DRAWING 54 NAME DRAWN DWG. NO. A SCALE:1:1 REV. R80500015B JOB #: SHEET 1 OF 1 CG-SVX038A-EN Electrical Schematics Figure 23. Low ambient damper schematic wiring and connections diagrams — CAUJ condenser control circuit modification: low ambient damper control by CCAR compressor chillers Low Ambient Schematic Wiring Diagram A B 2U83 (+) J2-4 (-) J2-3 P2-4 849A P2-3 848A A 2TB34-9 851 C F 2TB34-10 839 Low Ambient Connections Diagram 2U83 A J2 P2 851A 839F B C F 10839 A 9 851 2TB34 3 CG-SVX038A-EN 55 Electrical Schematics Figure 24. Instructions — CAUJ condenser control circuit modification: low ambient damper control by CCAR compressor chillers Trane CAUJ Condenser Control Circuit Modification Ambient Damper Control by Trane CCAR Compressor Chiller FOR ONE DAMPER ASSEMBLY: Step COMPLETE Initial/Date Reference Circle Instructions 1 A 2 B Disconnect plug 2U83P2 from the existing damper control board. (Leave the remaining plugs connected to the board for grounding.) Disconnect and tape wire 851A from 2TB34-9. Connect 0-10VDC signal from Trane chiller main board Analog Out (A-1) to 2TB34-9. FOR TWO DAMPER ASSEMBLIES: Step COMPLETE Initial/Date Reference Circle Instructions Disconnect plug 2U83P2 from the damper control box. (Leave the remaining plugs connected to the board for grounding.) 1 A 2 B Disconnect and tape wire 851A from 2TB34-9. Connect 0-10VDC signal from Trane chiller main board Analog Out (A-1) to 2TB34-9. 3 C Disconnect and tape wire 839F at 2TB34-10. Connect 0-10VDC signal from Trane chiller main board Analog Out (A-2) to 2TB34-10 NOTES: All CCAR/CAUJ applications require that the CCAR Compressor Chiller control the condenser ambient dampers (when applicable). For Ambient Control Dampers when applicable - One shielded pair for each damper assembly must be run from the CCAR Compressor Chiller to the CAUJ condenser. CCAR units are designed for operation down to a minimum of 40°F ambient. PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF TRANE. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF TRANE IS PROHIBITED. DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL MATERIAL NAME DATE LAH 09/19/13 CHECKED SMH 09/19/13 ENG APPR. EGN 09/19/13 MFG APPR. BAR 09/19/13 Q.A. COMMENTS: P.O. BOX 3066 LONGVIEW, TX 75606-3066 Trane CAUJ Condenser Control Circuit Modification: Ambient Damper Control by Trane CCAR Compressor Chiller FINISH SIZE DO NOT SCALE DRAWING 56 DRAWN DWG. NO. A SCALE:1:1 REV. R80500016B JOB #: SHEET 1 OF 1 CG-SVX038A-EN CG-SVX038A-EN DSW1 * THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. IMPORTANT GND C1 FU3 CC CC CLASS 3 1/ 100-5563 2 600 600 VOLTS FOR 208-230V UNITS 3 1/2 AMPS # BY DATE FU1,2 FUSE SCHEDULE FU1, FU2 ENGINEER'S SEAL C2 FUSE TYPE LITTELFUSE KLDR3 1/2 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY TRANSFORMER SECONDARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT2 1 TR1 2 SW 2 2 RELAY M-2 3 3 4 4 RELAY M-3 5 5 6 6 RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 7 7 8 8 9 9 10 10 11 11 12 13 12 13 14 14 15 15 16 16 17 17 UNIT CONTROLLER REVISION FU3 1 1 1 - CPS On/Off 2 - CKT1 Enable RELAY M-1 TBA PDB1 * CT1 RELAY M-4 FU4-6 18 18 RELAY M-9 19 19 Voltage 20 20 115v RELAY M-10 21 21 22 22 23 23 24 24 COM GROUND LUG TERMINAL BLOCK TBA P.O BOX 3066 LONGVIEW, TX 75606-3066 ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS TOOGLE SWITCH GND * PWM CIRCUIT FUSES - KTK OR EQ CURRENT TRANSFORMER MODULES * COMMUNICATIONS MODULE SW FU4,5,6 CT1-CT2 UNIT CONTROLLER POWER DISTRIBUTION BLOCK PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ 208,240,480/120 VAC 250 VA TRANSFORMER TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ * DISCONNECT SWITCH FU3 CCAR SCROLL 410A COMPRESSOR CHILLER TBA DSW1 FU1, FU2 LEGEND COMPRESSOR CONTACTORS * DIGITAL POWER MONITOR B R 8 05 0002 6 0 1 OF 1 P R ODUC T I ON SCALE: NA DRAWN BY: CHECKED BY: APP'D BY: DATE: 8/11/17 SMH BAR SMH DWG. SIZE TITLE: CONTROL PANEL LAYOUT 20 - 30 TON COMPRESSOR CHILLER 208V DRAWING NUMBER REV.SHEET NO. NAPPS JOB NO. * PWM COM * UC PWM C1-C2 Electrical Schematics Figure 25. Control panel layout for 20 to 30 ton, 208V, R-410A CCAR compressor chillers 57 DSW1 * THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. IMPORTANT GND C1 FU3 CC CC CLASS 3 1/ 2 1 1/2 100-5564 600 600 VOLTS FOR 460V UNITS AMPS # BY DA T E FU1,2 FUSE SCHEDULE LITTELFUSE KLDR3 /1 2 TRANSFORMER SECONDARY FU1, FU2 E NGI NE E R ' S S E A L C2 FUSE TYPE LITTELFUSE KLDR1 1/2 LOCATION TRANSFORMER PRIMARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT2 1 TR1 2 SW 2 2 RELAY M-2 3 3 4 4 5 5 6 6 RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 7 7 8 8 9 9 10 10 11 11 12 13 12 13 14 14 15 15 16 16 17 17 UNIT CONTROLLER R E V I S I ON FU3 1 1 1 - CPS On/Off 2 - CKT1 Enable RELAY M-1 TBA PDB1 * CT1 RELAY M-3 58 RELAY M-4 FU4-6 18 18 RELAY M-9 19 19 Voltage 20 20 RELAY M-10 21 115v 21 22 22 23 23 24 24 TBA GND SW FU4,5,6 CT1-CT2 COM R 8 05 0002 7 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. P R ODUC T I ON NAPPS JOB NO. B DWG. SIZE BAR APP'D BY: P.O. BOX 3066 LONGVIEW, TX 75606-3066 ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS TERMINAL BLOCK GROIUND LUG TOOGLE SWITCH * PWM CIRCUIT FUSES - KTK OR EQ CURRENT TRANSFORMER MODULES * COMMUNICATIONS MODULE UNIT CONTROLLER POWER DISTRIBUTION BLOCK PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ 208,240,480/120 VAC 250 VA TRANSFORMER TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ * DISCONNECT SWITCH FU3 CCAR SCROLL 410A COMPRESSOR CHILLER TBA DSW1 FU1, FU2 LEGEND COMPRESSOR CONTACTORS * DIGITAL POWER MONITOR SCALE: NA DRAWN BY: CHECKED BY: DATE: 8/11/17 SMH SMH TITLE: CONTROL PANEL LAYOUT 20 - 30 TON COMPRESSOR CHILLER 460V * PWM COM * UC PWM C1-C2 Electrical Schematics Figure 26. Control panel layout for 20 to 30 ton, 460V, R-410A CCAR compressor chillers CG-SVX038A-EN CG-SVX038A-EN DSW1 * THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. IMPORTANT GND C1 FU3 CC CC CLASS 3 1/2 1 1/4 100-5564A 600 600 VOLTS FOR 575V UNITS AMPS # BY DA T E FU1,2 FUSE SCHEDULE FU1, FU2 E NGI NE E R ' S S E A L C2 FUSE TYPE LITTELFUSE KLDR1 1/4 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY TRANSFORMER SECONDARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT2 1 TR1 2 SW 2 2 RELAY M-2 3 3 4 4 RELAY M-3 5 5 6 6 RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 7 7 8 8 9 9 10 10 11 11 12 13 12 13 14 14 15 15 16 16 17 17 UNIT CONTROLLER R E V I S I ON FU3 1 1 1 - CPS On/Off 2 - CKT1 Enable RELAY M-1 18 18 RELAY M-9 19 19 Voltage 20 20 115v RELAY M-10 21 21 22 22 23 23 24 24 TERMINAL BLOCK TBA P.O. BOX 3066L LONGVIEW, TX 75606-3066 ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS GROUND LUG TOOGLE SWITCH * PWM CIRCUIT FUSES - KTK OR EQ GND SW FU4,5,6 CURRENT TRANSFORMER MODULES * COMMUNICATIONS MODULE CT1-CT2 COM UNIT CONTROLLER POWER DISTRIBUTION BLOCK UC 600 VAC 250 VA TRANSFORMER TR1 TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ CCAR SCROLL 410A COMPRESSOR CHILLER TBA COMPRESSOR CONTACTORS * DISCONNECT SWITCH B R 8 05 0002 8 0 1 OF 1 P R ODUC T I ON APP'D BY: SCALE: NA DRAWN BY: CHECKED BY: DATE: 8/11/17 SMH SMH BAR DWG. SIZE TITLE: CONTROL PANEL LAYOUT 20 - 30 TON COMPRESSOR CHILLER 575V DRAWING NUMBER REV.SHEET NO. NAPPS JOB NO. * PWM COM * UC LEGEND * DIGITAL POWER MONITOR PDB1 FU3 FU1, FU2 DSW1 C1-C2 PWM Figure 27. TBA PDB1 * CT1 RELAY M-4 FU4-6 Electrical Schematics Control panel layout for 20 to 30 ton, 575V, R-410A CCAR compressor chillers 59 DSW1 * PDB1 IMPORTANT C1 THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. GND * CC CC CLASS 3 1/2 3 1/2 AMPS 600 600 VOLTS F O R 2 0 8 - 2 3 0 V U NITS 10 0 - 5 5 6 3 CT3 # BY FUSE SCHEDULE FU3 C2 LITTELFUSE KLDR3 /1 2 TRANSFORMER SECONDARY FU1, FU2 E NGI NE E R ' S S E A L C3 FUSE TYPE LITTELFUSE KLDR3 1/2 LOCATION TRANSFORMER PRIMARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT1 DA T E FU1,2 CT2 TR1 PWM * 1 1 2 2 1 4 4 5 5 FU3 3 3 6 6 2 7 7 8 8 9 9 1 1 2 2 TBD TBA R E V I S I ON 3 3 3 4 4 5 5 6 6 7 7 COM * RELAY M-2 FU4-6 8 8 RELAY M-3 RELAY M-1 60 9 9 10 10 RELAY M-4 1 - CPS On/Off SW 2 - CKT1 Enable 3 - CKT2 Enable RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 11 11 12 13 12 13 14 14 15 15 16 16 17 17 18 18 19 19 UNIT CONTROLLER 20 20 RELAY M-9 21 21 Voltage 22 22 RELAY M-10 23 23 115v PWM TERMINAL BLOCK FU3 FUSE TYPE L I MI T R ON K T K 1 LITTELFUSE 1 KLDR3 2 LITTELFUSE 1 KLDR3 2 R 8 05 00002 9 DRAWING NUMBER 1 OF 1 REV.SHEET NO. 0 1 3 1/2 3 1/2 600 6 00 600 P R ODUC T I ON NAPPS JOB NO. B DWG. SIZE APP'D BY: SMH P.O. BOX 3066 LONGVIEW, TX 75606-3066 CC CC AMPS FOR 208-230V UNITS CLASS CCAR SCROLL 410A COMPRESSOR CHILLER DIGITAL POWER MONITOR * SECONDARY TRANSFORMER FU4, FU5, FU6 * PRIMARY TRANSFORMER LOCATION FUSE SCHEDULE 1. ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS. NOTES: TERMINAL BLOCK TBA TBD EXPANSION BOARD SI 16-A04 EXPANSION BOARD RO10 EXP1 EXP2 TOGGLE SWITCHES GROUND LUG SW PWM CIRCUIT FUSES - KTK OR EQ DIGITAL POWER MONITOR CURRENT TRANSDUCER MODULES GND * * CT1-CT3 FU4,5,6 COMMUNICATIONS MODULE VOLTS POWER DISTRIBUTION BLOCK COM FU1, FU2 DESIGNATION TBA EXP1 208,240,480/120 VAC 250 VA TRANSFORMER UNIT CONTROLLER PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ DISCONNECT SWITCH FU3 * LEGEND COMPRESSOR CONTACTORS SCALE: 1:1 DRAWN BY: CHECKED BY: DATE: 8/8/2013 SMH BAR TITLE: CONTROL PANEL LAYOUT 40 - 65 TON COMPRESSOR CHILLER 208V 24 24 230V EXP2 UC * FU1, FU2 DSW1 C1-C3 Electrical Schematics Figure 28. Control panel layout for 40 to 65 ton, 208V, R-410A CCAR compressor chillers CG-SVX038A-EN TBD DSW1 * PDB1 IMPORTANT C1 CC CC CLASS 3 1/2 1 1/ 2 10 0 - 5 5 6 4 600 600 VOLTS F O R 4 6 0 V U NITS AMPS # FUSE SCHEDULE FU3 C2 LITTELFUSE KLDR3 /1 2 TRANSFORMER SECONDARY FU1, FU2 ENGINEER'S SEAL C3 FUSE TYPE LITTELFUSE KLDR1 1/2 LOCATION TRANSFORMER PRIMARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT1 BY DATE FU1,2 CT3 TR1 PWM * 1 1 3 3 FU3 2 2 1 4 4 5 5 6 6 7 7 2 8 8 9 9 TBA 1 1 2 2 3 3 REVISION TBD 3 4 4 5 5 6 6 7 7 COM * RELAY M-2 CT2 8 8 RELAY M-3 CG-SVX038A-EN THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. GND * FU4-6 9 9 10 10 RELAY M-4 RELAY M-1 1 - CPS On/Off SW 2 - CKT1 Enable 3 - CKT2 Enable RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 11 11 12 13 12 13 14 14 15 15 16 16 17 17 18 18 19 19 UNIT CONTROLLER 20 20 RELAY M-9 21 21 Voltage 22 22 RELAY M-10 23 23 115v PWM TERMINAL BLOCK CC CC CLASS R 8 05 0003 0 DRAWING NUMBER 0 1 OF 1 REV.SHEET NO. 600 6 00 600 P R ODUC T I ON NAPPS JOB NO. B DWG. SIZE APP'D BY: BAR 1 3 1/2 1 1/2 AMPS FOR 460V UNITS P.O. BOX 3066 LONGVIEW, TX 75606-3066 L I MI T R ON K T K 1 1 2 CCAR SCROLL 410A COMPRESSOR CHILLER DIGITAL POWER MONITOR * LITTELFUSE 1 KLDR3 2 SECONDARY TRANSFORMER FU3 FU4, FU5, FU6 * LITTELFUSE KLDR1 FUSE TYPE FUSE SCHEDULE PRIMARY TRANSFORMER LOCATION 1. ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS. NOTES: TERMINAL BLOCK TBD EXPANSION BOARD SI 16-A04 EXPANSION BOARD R010 EXP2 TBA TOGGLE SWITCHES GROUND LUG GND EXP1 PWM CIRCUIT FUSES - KTK OR EQ DIGITAL POWER MONITOR CURRENT TRANSFORMER MODULES SW * * CT1-CT3 FU4,5,6 COMMUNICATIONS MODULE VOLTS POWER DISTRIBUTION BLOCK COM FU1, FU2 DESIGNATION TBA EXP1 EXP2 208,240,480/120 VAC 250 VA TRANSFORMER UNIT CONTROLLER PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ DISCONNECT SWITCH FU3 * LEGEND COMPRESSOR CONTACTORS SCALE: 1:1 DRAWN BY: CHECKED BY: SMH SMH DATE: 9/27/13 TITLE: CONTROL PANEL LAYOUT 40 - 65 TON COMPRESSOR CHILLER 460V 24 24 230V UC * FU1, FU2 DSW1 C1-C3 Electrical Schematics Figure 29. Control panel layout for 40 to 65 ton, 460V, R-410A CCAR compressor chillers 61 TBD DSW1 * PDB1 IMPORTANT THE INFORMATION CONTAINED HEREON, WHICH IS THE PROPERTY OF TRANE, MUST BE MAINTAINED IN STRICT CONFIDENCE AND NO PORTION OF THIS MATERIAL MAY BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN CONSENT OF TRANE. GND * FU4-6 C1 CC CC CLASS 3 1/2 1 1/4 10 0 - 5 5 6 4 600 600 VOLTS F O R 4 6 0 V U NITS AMPS # BY TR1 PWM * 1 1 2 2 3 3 4 4 FU3 1 5 5 6 6 2 7 7 9 9 1 1 TBD TBA REVISION 8 8 3 2 2 3 3 4 4 5 5 6 6 7 7 COM * RELAY M-2 CT2 DATE FU1,2 CT3 FUSE SCHEDULE FU3 C2 FU1, FU2 ENGINEER'S SEAL C3 FUSE TYPE LITTELFUSE KLDR1 1/4 LITTELFUSE KLDR3 /1 2 LOCATION TRANSFORMER PRIMARY TRANSFORMER SECONDARY DESIGNATION TRANSFORMER FUSE SCHEDULE CT1 8 8 RELAY M-3 RELAY M-1 62 9 9 10 10 RELAY M-4 1 - CPS On/Off SW 2 - CKT1 Enable 3 - CKT2 Enable RELAY M-8 RELAY M-7 RELAY M-6 RELAY M-5 11 11 12 13 12 13 14 14 15 15 16 16 17 17 18 18 19 19 UNIT CONTROLLER 20 20 RELAY M-9 21 21 Voltage 22 22 RELAY M-10 23 23 115v TERMINAL BLOCK TERMINAL BLOCK TBA TBD P.O. BOX 3066 LONGVIEW, TX 75606-3066 R80500031 DR A WI NG NUMB E R 0 1 OF 1 REV. SHEET NO. PRODUCTION NA P P S J OB NO. B DWG. SIZE APP'D BY: BAR 1. ITEMS MARKED WITH * ARE OPTIONAL AND ARE NOT ON ALL UNITS. NOTES: EXPANSION BOARD SI 16-A04 EXPANSION BOARD R010 EXP2 GROUND LUG EXP1 TOGGLE SWITCHES SW CCAR SCROLL 410A COMPRESSOR CHILLER TBA EXP1 CURRENT TRANSFORMER MODULES GND PWM * DIGITAL POWER MONITOR FU4,5,6 * PWM CIRCUIT FUSES - KTK OR EQ CT1-CT3 COMMUNICATIONS MODULE POWER DISTRIBUTION BLOCK COM * 600 VAC 250 VA TRANSFORMER UNIT CONTROLLER PDB1 UC TR1 SECONDARY CIRCUIT FUSE - KLDR OR EQ TR1 TR1 PRIMARY CIRCUIT FUSES - KLDR OR EQ DISCONNECT SWITCH SCALE: 1:1 DRAWN BY: CHECKED BY: DATE: 9/30/13 SMH SMH TITLE: CONTROL PANEL LAYOUT 40 - 65 TON COMPRESSOR CHILLER 575V 24 24 230V EXP2 UC * LEGEND COMPRESSOR CONTACTORS FU3 FU1, FU2 DSW1 C1-C3 Electrical Schematics Figure 30. Control panel layout for 40 to 65 ton, 575V, R-410A CCAR compressor chillers CG-SVX038A-EN TBD Appendix Vendor Data Sheet MSC-CT300 Current Transducer Data Sheet The MCS-MAGNUM-N MCS-CT300 Dimensions: Height ................................................... 4.00” Width .................................................... 2.38” Depth .................................................... 1.56” Wire Hole .............................................. 1.00” Amperage Rating.................................. 0-300A Accuracy ............................................... ± 3 amps Sensor Output Voltage ......................... 0-5vdc Supply Voltage...................................... Induced Operating Temperature ......................-40°F to +158°F (-40°C to +70°C) Storage Temperature..........................-40°F to +158°F (-40°C to +70°C) Part # MCS-CT300 Description The MCS-CT300 electrical equipment. The magnitude of the current is converted to a linear 0 to 5vdc output signal which can be read as a standard analog input signal. The signal is used by MCS micro controllers for the following: Amps Volts dc Amps Volts dc 10 0.13 160 2.71 20 0.30 170 2.88 1. For slide valve positioning on screw machines 30 0.48 180 3.05 2. For high amp motor overload protection 40 0.65 190 3.22 50 0.82 200 3.39 60 0.99 210 3.56 70 1.16 220 3.73 80 1.34 230 3.91 90 1.51 240 4.06 100 1.68 250 4.23 110 1.85 260 4.40 120 2.02 270 4.58 130 2.19 280 4.74 140 2.36 290 4.91 150 2.53 300 5.08 4. Used in kw calculations The MCS-CT300 is a solid-core version, so the conductor runs through the sensor. No cutting, taping or rerouting is required. It is accurate, reliable, easy to install and requires no service. The MCS-CT300 has an accuracy of ± 3 amps in the frequency range from 50-60Hz. The sensor outputs a 0 to 5vdc signal. The sensor power is induced from the current being monitored. On the printed circuit board, a resistor is mounted across the CT terminals, which eliminates danger from induced current. A removable three-position terminal block is provided for easy wiring. A two-conductor shielded cable must be used. The shield must be cut at the MCS-CT300 end and tied to ground at the MCS micro controller terminal block. Revision 2015-08-07 5580 Enterprise Pkwy., Fort Myers, FL 33905 For complete temperature chart, refer to the MCS-T100 spec sheet CG-SVX038A-EN 63 Appendix MSC-667F Pressure Transducer Data Sheet The MCS-667B-xx MCS-MAGNUM-N S ee S ee Speci c tions Part # MCS-667B-xx Description L 90180 MADE IN USA The MCS-667B pressure trans ucer is specially esigne for use in high pressure H AC refrigeration applications, in the most eman ing environments, where low cost is nee e yet maintaining high accuracy, long term relia ility, an long life. Features inclu e, high accuracy, wi e temperature range, esign for outrefrigerant me ia compati ility an rugge oor use. The MCSB pressure trans ucer is CE, L an RoHs B compliant. It is capa le of surviving high vi ration. MCSis a seale gage pressure trans ucer with a cavity uilt out of stainless steel with a Neoprene sealing material, ¼” SAE Female Flare tting Schra er valve 1 - 0 NF pipe threa which creates a leak-proof, all metal seale system that makes the B i eal for use with rugge H AC environments using MCSrefrigerant Me ia. Pressure Range............... 0 to psi seale gauge Housing ........................... Stainless Steel Sealing Material ...............Neoprene Electrical Connection ....... P Operating Temperature.... - 0 F to 5 F - 0 C to 1 5 C Accuracy .......................... .0 - 0 F to - F - 0 C to - 0 C 1.5 - F to 3 F - 0 C to 0 C 1.0 3 F to 1 F 0 C to 80 C 1.5 1 F to 8 F 80 C to 1 0 C .0 8 F to 5 F 1 0 C to 1 5 C Agency Approvals ............ CE, L E3 390 , RoHS Proof Pressure.................ma 000 Burst Pressure ................... ma 3000 Ran om i ration ...........5 G @ 33Hz nput oltage....................5v c 0. 5 c Input Current.................... 10 ma 0.01 amps Output oltage .................0.5 to .5 c ratio metric Connection ...................... SAE Female Flare tting Schra er valve 1 - 0 NF threa Option Cable: Connector ........................Packar with Silicone seal Length.............................. 0 , 0 or 0 feet Type .................................3-con uctor, 0 awg stran e Shiel ...............................Foil shiel with 5 overlap Drain ................................Stran e tinne copper rain When ordering replace -xx with: ....................................... 0 0 or 0 wire length The ca le is availa le in either 0 , 0 or 0 lengths with a remova le Packar connector to provi e easy servicea ility. The wire is seale an crimpe to the Packar connector provi ing a li ui tight environment an strain relief. *IP66 Rating A le to protect against powerful water ets ater pro ecte in powerful ets 1 .5 mm nozzle against the enclosure from any irection shall have no harmful effects. ater volume 100 litres . gals per minute Pressure 100 kPa 1 .50psi at istance of 3 m 9.8 ft 1 meter in epth. 100 10 200 1.70 300 2.30 400 2.90 500 3.50 600 4.10 56 110 16 210 1.76 310 2.36 410 2.96 510 3.56 610 4.16 62 120 22 220 1.82 320 2.42 420 3.02 520 3.62 620 4.22 68 130 28 230 1.88 330 2.48 430 3.08 530 3.68 630 4.28 74 140 1.34 240 1.94 340 2.54 440 3.14 540 3.74 640 4.34 80 150 1.40 250 2.00 350 2.60 450 3.20 550 3.80 650 4.40 86 160 1.46 260 2.06 360 2.66 460 3.26 560 3.86 660 4.46 0.92 170 1.52 270 2.12 370 2.72 470 3.32 570 3.92 667 4.50 0.98 180 1.58 280 2.18 380 2.78 480 3.38 580 3.98 04 190 1.64 290 2.24 390 2.84 490 3.44 590 4.04 e ision - 01 -0 - 1 f ce 64 5580 Enterprise Pkwy., Fort Myers, FL 33905 For complete temperature chart, refer to the MCS-T100 spec sheet 39- 9 -0089 Fa 39- 9 -0031 www.mcscontrols.com CG-SVX038A-EN Appendix The MCS-T100 Specifications and Description The MCS-MAGNUM-N MCS-T100 Standard Temperature Range............... Standard Temperature Accuracy .. ...... .. Resistance Range ........................ ....... ....... Input Voltage................................. 5vdc Sensor Resistance ........................... Dimensions ................................... Material ......................................... Stainless Steel Environmental rating..................... Testing .......................................... 10,000 freeze/thaw thermal cycles Part # Description The for demanding environments. It is ideal for high moisture locations with continuous freeze and thaw cycles. The sensor is potted with a thermally conductive RTV Cure Silicon Adhesive to guarantee - Temp (°F / °C) Resist (ohms) S1 (vdc) Temp (°F / °C) Resist (ohms) S1 (vdc) Temp (°F / °C) Length........................................... Wire ................................................. Shield............................................ Drain ................................................Stranded tinned copper drain ............................................................ wire length Resist (ohms) S1 (vdc) Temp (°F / °C) Resist (ohms) S1 (vdc) Temp (°F / °C) Resist (ohms) S1 (vdc) -40/-40 4,015,500 0.121 32/0 351,020 1.109 95/35 63,480 3.058 158/70 15,500 4.329 208/97.7 5,981 4.718 -35/37.2 3,324,096 0.146 35/1.6 320,976 1.188 100/37.7 56,200 3.201 160/71.1 14,881 4.352 210/98.8 5,773 4.727 -30/34.4 2,760,524 0.175 38/3.3 293,758 1.270 104/40 51,050 3.310 165/73.8 13,456 4.407 212/100 5,573 4.736 -25/-31.6 2,299,670 0.208 40/4.4 277,040 1.326 105/40.5 49,846 3.337 167/75 12,930 4.428 215/101.6 5,289 4.749 -20/-28.9 1,921,640 0.247 45/7.2 239,686 1.472 110/43.3 44,287 3.465 170/76.6 12,185 4.457 218/103.3 5,020 4.761 -15/-26.1 1,610,592 0.292 50/10 207,850 1.624 113/45 41,290 3.539 175/79.4 11,052 4.502 220/104.4 4,849 4.769 -10/-23.3 1,353,866 0.344 55/12.7 180,647 1.782 115/46.1 39,420 3.586 180/82.2 10,033 4.544 223/106.1 4,605 4.780 -5/-20.6 1,141,345 0.403 58/14.4 166,243 1.878 120/48.8 35,149 3.697 183/83.8 9,474 4.567 225/107.2 4,449 4.787 0 /-17.7 964,963 0.470 60/15.5 157,353 1.943 125/51.6 31,399 3.805 185/85 9,121 4.582 227/108.3 4,299 4.794 5/-15.0 818,070 0.545 65/18.3 137,363 2.106 130/54.4 28,093 3.903 190/87.7 8,303 4.617 230/110 4,085 4.804 10/-12.2 695,433 0.629 70/21.1 120,169 2.271 135/57.2 25,173 3.994 195/90.5 7,567 4.648 233/111.6 3,886 4.813 15 /-9.4 592,755 0.722 75/23.9 105,347 2.435 140/60 22,590 4.079 198/92.2 7,162 4.666 235/112.7 3,760 4.819 20/-6.6 506,560 0.824 80/26.7 92,541 2.597 145/62.8 20,309 4.156 200/93.3 6,906 4.677 240/115.5 3,463 4.833 25/-3.8 434,007 0.936 85/29.4 81,454 2.756 150/65.5 18,284 4.227 203/95 6,541 4.693 245/118.3 3,191 4.845 30/-1.1 372,778 1.058 90/32.2 71,838 2.910 155/68.3 16,484 4.292 205/96.1 6,310 4.703 248/120 3,040 4.852 5580 Enterprise Pkwy., Fort Myers, FL 33905 For complete temperature chart, refer to the MCS-T100 spec sheet CG-SVX038A-EN 65 Appendix Warranty I. Limited Product Warranty & Service Policy Napps Technology, Inc. (NAPPS) warrants for a period of twelve (12) months from date of original shipment that all products, manufactured by NAPPS, with the exception of packaged refrigeration products, are free from defects of material and workmanship when used within the service, range, and purpose for which they were manufactured. Packaged refrigeration products shall be so warranted for a period of twelve (12) months from date of start-up or eighteen (18) months from date of original shipment, whichever may first occur. Service Parts shall be so warranted for a period of ninety (90) days from date of installation, or twelve (12) months from date of original shipment, whichever may first occur. In case material is rejected on inspection by the buyer as defective, NAPPS shall be notified in writing within ten (10) days from receipt of said material. NAPPS will then have the option of re-inspection at the buyer’s plant or its own plant before allowing or rejecting the buyer's claim. Expenses incurred in connection with claims for which NAPPS is not liable may be charged back to the buyer. No claim for correction will be allowed for work done in the field except with the written consent of NAPPS. Defects that do not impair service shall not be cause for rejection. NAPPS assumes no liability in any event for consequential damages. No claim will be allowed for material damaged by the buyer or in transit. Defective equipment or parts shall be returned to NAPPS freight prepaid. NAPPS will, at its option, repair, replace or refund the purchase price of products found by NAPPS to be defective in material or workmanship provided that written notice of such defect requesting instruction for repair, replacement or refund is received by NAPPS within ten (10) days of determination of said defect, but not more than one (1) year after the date of shipment, and provided that any instructions given thereafter by NAPPS are complied with. Any products covered by this order found to NAPPS' satisfaction to be defective upon examination at NAPPS' factory will, at NAPPS’ option, be repaired or replaced and returned to Buyer via lowest cost common carrier, or NAPPS may, at its option, grant Buyer a credit for the purchase price of the defective article. Without limitation of the foregoing, this warranty shall not apply to (i) deterioration by corrosion or erosion of material or any cause or failure other than defect of material or workmanship; (ii) the performance of any system of which NAPPS’ products are a component part; or (iii) any of NAPPS’ products or parts thereof which have been subjected to alteration or repair by anyone other than NAPPS or someone authorized by NAPPS, or subjected to misuse, neglect, free chemicals in system, corrosive atmosphere, abuse or improper use or misapplication such as breakage by negligence, accident, vandalism, the elements, shock, vibration or exposure to any other 66 service, range or environment of greater severity than that for which the products were designed, or if operation is contrary to NAPPS’ or manufacturer’s recommendation, or if the serial number has been altered, defaced or removed. Hermetic motor/compressors furnished by NAPPS are subject to the standard warranty terms set forth above, except that the hermetic motor/compressor replacements or exchanges shall be made through the nearest authorized wholesaler of the hermetic motor/compressor manufacturer (not NAPPS’ factory) and no freight shall be allowed for transportation of the hermetic motor/ compressor to and from the wholesaler. For TRANE hermetic motor/compressors, the nearest wholesaler referred to herein shall be the nearest TRANE PARTS CENTER. The replacement hermetic motor/compressor shall be identical to the model of the hermetic motor/ compressor being replaced. Additional charges, which may be incurred through the substitution of other than identical replacements, are not covered by this warranty. Evaporator failure due to fluid freezing that is the result of low fluid flow or inadequate fluid freeze protection, for applications with leaving fluid temperatures below 40°F, is not covered by this warranty. The Warranty provided above is the only Warranty made by NAPPS with respect to its products or any parts therefore and is made expressly in lieu of any other Warranties, by course of dealing, usages of trade or otherwise, expressed or implied, including but not limited to any implied Warranties of fitness for any particular purpose or of merchantability under the uniform commercial code. It is agreed that this Warranty is in lieu of and buyer hereby waives all other warranties, guarantees or liabilities arising by law or otherwise. NAPPS shall not incur any other, obligations or liabilities or be liable to buyer or any customer of buyer for any anticipated or lost profits, incidental or consequential damages, or any other losses or expenses incurred by reason of the purchase, installation, repair, use or misuse by buyer or third parties of its products (including any parts repaired or replaced); and NAPPS does not authorize any person to assume for NAPPS any other liability in connection with the products or parts therefore. NAPPS shall not be responsible for the loss or replacement of or the addition of compressor oil, or refrigerant.This Warranty cannot be extended, altered or varied except by a written instrument signed by NAPPS and buyer. II. Limitation Of Liability NAPPS shall not be liable, in contract or in tort, for any special, indirect, incidental or consequential damages, such as, but not limited to, loss of profits, or injury or damage caused to property, products, or persons by reason of the installation, modification, use, repair, maintenance or mechanical failure of any NAPPS product. CG-SVX038A-EN Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. CG-SVX038A-EN 11 Sep 2017 (NEW) ©2017 Ingersoll Rand ">
/
Shkarko
Vetëm një kujtesë miqësore. Ju mund ta shikoni dokumentin këtu. Por më e rëndësishmja, AI ynë tashmë e ka lexuar atë. Ai mund të shpjegojë gjëra komplekse në terma të thjeshtë, t''u përgjigjet pyetjeve tuaja në çdo gjuhë dhe t''ju ndihmojë të lundroni shpejt edhe në dokumentet më të gjata ose më të komplikuara.
Reklamë