Wolf CTWH36 is a cooktop wall hood designed to powerfully draw odors and smoke into its five-layer mesh filter. The filter is removable for easy cleaning, keeping your kitchen fresh and clean effortlessly. With three-speed blower control, you can adjust the fan speed to your cooking needs. Halogen lighting with three settings provides bright illumination for your cooking surface, while the heat sentry feature automatically adjusts fan speed based on heat levels.
Advertisement
Advertisement
Planning Information
Model CTWH36 Cooktop Wall Hood
Model CTWH36
Transition with backdraft damper
Classic stainless steel finish
Seamless
Construction
Aluminum mesh filter
LED indicators
Front mounted controls
Three-speed blower control
Halogen lighting
Rating plate location
Wolf cooktop wall ventilation hoods are available in the classic stainless steel finish. Cooktop wall hoods are sold as a shell only, internal, in-line and remote blower options are available.
P owerful multi-speed blowers draw odors and smoke into the five-layer mesh filter. Filters remove easily for cleaning. The sculpted classic stainless steel shape not only provides the power you expect from Wolf, but also the beauty you have come to appreciate as well.
This wall mount cooktop hood is 36" (914) wide by 21" (533) deep. It has a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available as a sales accessory.
Wolf cooktop wall hoods are recommended for use with Wolf electric and gas cooktops and integrated modules. For Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops, a Pro ventilation hood should be used.
Dimensions in parentheses are in millimeters unless otherwise specified.
9/06
1
Planning Information
Model CTWH36 Cooktop Wall Hood
F E A T U R E S
Classic stainless steel finish
Internal, in-line and remote blower options
Front mounted controls with LED indicator
Heavy-duty stainless steel seamless construction
Three-speed blower control
Variable speed blowers
Filter clean timer lets you know when the filter needs cleaning
Delay-off mode automatically turns unit off
Sealed halogen lighting with three settings
Stainless steel filter cover with dishwasher safe aluminum mesh filter
Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed
Transition with backdraft damper included
Fits 8' (2.4 m) to 9' (2.7 m) ceilings – flue extension to accommodate 10’ (3 m) ceilings is available as a sales accessory
UL listed to US and Canadian safety standards
Two and five year residential warranty – exclusions apply; warranty information can be found on our website, wolfappliance.com
O V E R A L L D I M E N S I O N S
35 7 /
18"
(457)
16 " (900)
OVERALL WIDTH
32 11 / 16 " TO 50 7 / 8 "
(830 – 1292)
OVERALL HEIGHT
8 11 / 16 "
(221)
12"
(305)
4 5 / 16 " min
(110)
19 1 / 8 "
(486)
21" (533)
OVERALL DEPTH
1 9 / 16 "
(40)
9 1 / 4 "
(235)
Dimensions may vary by ± 1 /
8
" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
2
Planning Information
Model CTWH36 Cooktop Wall Hood
B L O W E R O P T I O N S
600 CFM Internal Blower
900 CFM Internal Blower
600 CFM In-Line Blower
1100 CFM In-Line Blower
600 CFM Remote Blower
900 CFM Remote Blower
1200 CFM Remote Blower
1500 CFM Remote Blower
801644
801645
808331
808332
801640
801641
801642
804701
Model CTWH36 is sold as a shell only, an internal, in-line or remote blower will be required. Refer to Wolf Cooktop
Ventilation Recommendations at the end of this section.
A C C E S S O R I E S
36" (914) wall shield
Flue extension to accommodate
10' (3 m) ceilings
8" (203) to 10" (254) round transition
Accessories are available through your
Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
S P E C I F I C A T I O N S
Overall Width
Overall Height (excluding chimney)
Overall Height (including chimney)
35 7 /
16
" (900)
9 1 /
4
" (235)
32 11 /
16
" (830)
50 7 /
8
" (1292) Maximum Height (full extension)
Overall Depth
Transition
Duct Size
21" (533)
8" (203) to 10" (254) round
8" (203) round
Discharge
Electrical Supply Requirements
Shipping Weight
Vertical
110 /120 V AC, 60 Hz
15 amp dedicated circuit
100 lbs (45 kg)
Specifications are subject to change without notice.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Planning Information
Model CTWH36 Cooktop Wall Hood
21"
(533)
50 7 / 8 "
(1292)
MAXIMUM
HEIGHT OF HOOD
4" (102)
6"
(152)
E
35 7 / 16 "
(900)
8' TO 9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO 30"
(610 – 762)
TO COUNTERTOP
32 11 / 16 "
(830)
MINIMUM
HEIGHT OF HOOD
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 27
5
/ 16 " (694).
D I M E N S I O N S
Overall Width of Hood
Floor to Ceiling Height
Countertop to Bottom of Hood
Minimum Height of Hood (fully collapsed)
Maximum Height of Hood (full extension)
Location of Electrical
See Installation Instructions shipped with unit for detailed specifications.
35 7 /
16
" (900)
8' (2.4 m) to 9' (2.7 m)
24" (610) to 30" (762)
32 11 /
16
" (830)
50 7 /
8
" (1292)
Within shaded area
Dimensions in parentheses are in millimeters unless otherwise specified.
4
Planning Information
Model CTWH36 Cooktop Wall Hood
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions and installation specifics.
Wolf cooktop wall hoods are recommended for use with Wolf electric and gas cooktops and integrated modules. The hood should be at least as wide as the cooking surface.
IMPORTANT NOTE: Wolf Pro ventilation hoods should be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops.
Wolf cooktop wall hoods come with a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate
10' (3 m) ceilings is available as a sales accessory.
Installation of the cooktop wall hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration.
IMPORTANT NOTE: 8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of
27 5 / 16 " (694).
Wolf cooktop wall hoods are shipped without a blower assembly. Internal, in-line and remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for ventilation recommendations and blower options.
IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower.
Wolf cooktop wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply.
The service should have its own 15 amp circuit breaker. Placement of the outlet is not critical, as long as you provide a minimum of 12" (305) of 120 V AC, 60 Hz power cable. Locate electrical within the shaded area shown in the
Installation illustration.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
Wolf cooktop wall hoods have an 8" (203) round vertical discharge.
Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Planning Information
Model CTWH36 Cooktop Wall Hood
(E)
UPPER FLUE TOTAL
HEIGHT TO CEILING
(F)
MAXIMUM
HEIGHT OF
HOOD
(D)
BOTTOM
OF HOOD TO
MINIMUM FLUE
EXTENSION
(A)
TOTAL
FLOOR TO
CEILING
HEIGHT (C)
COUNTERTOP
TO BOTTOM
OF HOOD
(B)
FLOOR TO
COUNTERTOP
HEIGHT
C O O K T O P H O O D P L A C E M E N T
Wolf cooktop wall ventilation hoods come with a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available as a sales accessory.
Installation of the wall hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop.
IMPORTANT NOTE: 8' (2.4 m) ceilings will not allow for a 30"
(762) maximum height above the countertop. Based on a 36"
(914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 27 5 /
16
" (694).
IMPORTANT NOTE: Both sections of the telescopic chimney flue must be installed in order for the chimney to be lifted for service.
To determine placement of the cooktop wall hood, you must calculate the height of the telescopic chimney flue. Refer to the illustration and chart below.
To calculate the height of the telescopic chimney flue:
1) First measure A (total kitchen height from finished floor to finished ceiling height).
2) Next measure B (height from finished floor to countertop).
3) Then determine the minimum C value (distance from countertop to bottom of hood). Refer to the chart for ceiling heights from 8' (2.4 m) to 9' (2.7 m). Dimension C must be greater than 24" (610) and less than 30" (762).
4) To determine the upper flue section height: E=A-(C+B+D) .
IMPORTANT NOTE: If dimension E falls between 0" (0) and
1 /
2
" (13), you will need to modify the flue to affix to the flue attachment brackets. For ease of installation, Wolf recommends that dimension E be no less than 1 /
2
" (13).
M O D E L C T W H 3 6
(A)
96" (2438)
96" (2438)
108" (2743)
108" (2743)
(B)
36" (914)
36" (914)
36" (914)
36" (914)
(C)
24" (610) min 32
11
/
(D)
16
" (830)
27
5
/
16
" (694) max 32
11
/
16
" (830)
24" (610) min
30" (762) max
32
11
/
16
" (830)
32
11
/
16
" (830)
Letters correspond to those in the illustration.
3
(E)
5
/
16
" (84)
0"
15
7
/
16
" (392)
9
5
/
16
" (237)
50
50
50
50
(F)
7
/
8
" (1292)
7
/
8
" (1292)
7
/
8
" (1292)
7
/
8
" (1292)
Dimensions in parentheses are in millimeters unless otherwise specified.
6
Planning Information
Model CTWH36 Cooktop Wall Hood
D U C T I N G C O N S I D E R A T I O N S
Wolf cooktop wall hoods are shipped without the blower assembly. Internal, in-line or remote blower assemblies are available. For wall hoods, the remote blower can be mounted on the roof or an exterior wall.
IMPORTANT NOTE: Install these ventilation hoods only with a Wolf blower.
Wolf cooktop wall hoods have an 8" (203) round vertical discharge. Ducting for wall hoods can run through the roof or an external wall as shown in the illustration below.
Refer to the Cooktop ventilation charts at the end of this section for recommendations and blower options.
DUCTWORK INSTALLATION
THROUGH ROOF
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
8" (203) ROUND DUCT
CHIMNEY FLUE EXTENSION
TELESCOPIC CHIMNEY FLUE
8" (203) ROUND ELBOW
8" (203) ROUND DUCT
6 7 /
8
"
(175) OR
9 1 /
4
"
(235)
COOKTOP
WALL HOOD
21"
(535)
24"
TO
30"
(610 – 762)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
WALL CAP
OR REMOTE BLOWER
DUCTWORK INSTALLATION
THROUGH WALL
8" (203) ROUND
VERTICAL DISCHARGE
Ducting considerations cooktop wall hoods.
Dimensions in parentheses are in millimeters unless otherwise specified.
7
Planning Information
Wolf Ventilation Recommendations
W O L F B L O W E R A S S E M B L I E S
A ventilation system must include a blower assembly. With a few exceptions where internal blowers are included, Wolf ventilation hoods and downdrafts are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer.
Wolf internal, in-line and remote blowers are for use with Wolf cooktop hoods, downdraft systems and Pro ventilation hoods and hood liners.
IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products.
Internal blowers are mounted inside the hood canopy or downdraft blower box. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers.
Ventilation recommendation charts on the following pages provide minimum CFM recommendations according to the cooking appliance and ventilation system used and blower options for each specific ventilation hood or downdraft.
24 3 / 8 "
(619)
11 3 /
4
"
(298)
18 1 / 2 "
(470)
4
1
/ 2 "
(114)
21
1
/ 2 "
(546) 12
1
/ 4 "
(311)
24
7/8
"
(632)
18"
(457)
12"
(305)
22"
(559)
8"
(203)
18"
(457)
In-line BLOWER-60IL In-line BLOWER-110IL
28 1/4 "
(718)
15
1/2
"
(394)
10" (254)
Diameter
20 3/4 "
(527)
24 1/2 "
(622)
29
1/2
"
(749)
14 3/4 "
(375)
10" (254)
Diameter
18"
(457)
10"
(254)
29 1/2 "
(749)
14"
(356)
24 3/4 "
(629)
4
3/4
"
(121)
10
1/8
"
(257)
22"
(559)
Remote BLOWER-60REM and
BLOWER-90REM
Dimensions may vary by ± 1 /
8
" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
Remote BLOWER-120REM
7 1/4 "
(184)
29 1/2 "
(749)
14
3/4
"
(375)
10"
(254)
Diameter
21"
(533)
10"
(254)
29 1/2 "
(749)
10
3/8
"
(264)
25"
(635)
Remote BLOWER-150REM
7 1/4 "
(184)
8
Planning Information
Wolf Cooktop Ventilation Recommendations
C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O N S
Cooktop Hoods, Downdrafts and Pro Hoods
CTWH30 CTWH36
Electric Cooktops
Model CT15E
Model CT30E
Model CT30EU
Model CT36E
Model CT36EU
215*
450
450
215*
600
600
600
600
IH4227
215*
600
600
600
600
DD30
215*
500
Gas Cooktops
Model CT15G
Model CT30G
Model CT36G
CTWH30 CTWH36 IH4227
215*
450
215*
600
600
215*
600
600
DD30
215*
500
DD36
500
DD36
DD45
150*
350
Pro Hoods
215*
600
600
600
600
DD45 Pro Hoods
150*
350
215*
600
600 500
CTWH30 CTWH36 IH4227 DD30 DD36
Modules
Model CT15I
Model IG15
Model IS15
Model IF15
Model IM15
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
215*
*Use these requirements to determine total CFM when installing multiple cooktops or modules.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW).
Additional CFM may be required for long duct runs.
DD45
150*
150*
Pro Hoods
215*
215*
215*
215*
215*
C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S
Cooktop Ventilation Hoods
Blower Description
450 CFM Internal
600 CFM Internal
900 CFM Internal
600 CFM In-Line
1100 CFM In-Line
600 CFM Remote
900 CFM Remote
1200 CFM Remote
1500 CFM Remote
Blower Number
CTBLOWER-45INT (801643)
CTBLOWER-60INT (801644)
CTBLOWER-90INT (801645)
BLOWER-60IL (808331)
BLOWER-110IL (808332)
BLOWER-60REM (801640)
BLOWER-90REM (801641)
BLOWER-120REM (801642)
BLOWER-150REM (804701)
Cooktop Hood Models
CTWH30
CTWH36 / IH4227
CTWH36 / IH4227
CTWH30 / CTWH36 / IH4227
CTWH30 / CTWH36 / IH4227
CTWH30 / CTWH36 / IH4227
CTWH30 / CTWH36 / IH4227
CTWH30 / CTWH36 / IH4227
CTWH30 / CTWH36 / IH4227
Vertical discharge with 8" (203) round duct for wall and island hoods. Transition is not required for internal blowers; in-line and remote blowers require TRANS-8-10. Backdraft damper included with wall and island hoods.
Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product.
Always consult a qualified HVAC Engineer for specific applications.
Dimensions in parentheses are in millimeters unless otherwise specified.
9