Advertisement
Advertisement
WOLF VENTILATION GUIDE
Contents
Wolf Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Selecting a Ventilation System . . . . . . . . . . . . . . . . . . . 4
Ventilation Made Easy . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wolf Cooktop Ventilation . . . . . . . . . . . . . . . . . . . . . . 14
Wolf Pro Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Wolf Blower Specifications . . . . . . . . . . . . . . . . . . . . . 44
Wolf Ventilation FAQ . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Wolf Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Features and specifications are subject to change at any time without notice. Visit our website, wolfappliance.com for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
IMPORTANT NOTE: Wolf prefers an HVAC contractor approve the airflow characteristics of any ventilation and duct work system. This includes approval of what direction duct runs and any variables related to installation that are not called out in our specifications. Variance from our recommendations must be validated by an HVAC specialist as well as verification of air flow and speeds to insure proper ventilation.
Important Note
Wolf cooking products do not require ventilation when installed according to the installation instructions.
Recommendations and suggestions in this guide are for performance only.
To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially important.
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Wolf Ventilation 3 wolfappliance.com/specs
Wolf Ventilation.
Ventilation is an integral part of any kitchen. Proper ventilation provides a cleaner, healthier, more enjoyable cooking environment by removing moisture, odor and unhealthy by-products of combustion, including carbon monoxide. Proper ventilation is essential for maintaining a healthy indoor environment and minimizing airborne health risks.
Ventilation can provide a dramatic focal point for your kitchen or it can be concealed for an integrated look. Wolf ventilation systems are precisely crafted for both function and design.
Choosing the proper ventilation system is one of the most important decisions you can make when designing your kitchen.
Wolf has ventilation products to satisfy all needs and preferences. When selecting a ventilation system, it is important to note that Wolf ventilation systems are divided into two categories: cooktop ventilation and pro ventilation.
Cooktop ventilation.
Pro ventilation.
Selecting a Ventilation System
Selecting a Ventilation System
COOKTOP OR PRO VENTILATION
Wolf cooktop ventilation hoods can be used with Wolf induction, electric and gas cooktops and integrated modules. Wolf downdraft systems can be used with Wolf framed induction, framed electric and gas cooktops and some integrated modules. Downdrafts cannot be installed with unframed induction and unframed electric cooktops, and steamer and fryer modules. They are not recommended for use with the grill module.
For Wolf ranges and rangetops, a pro ventilation hood or hood liner should be used. A downdraft can be used with sealed burner rangetop models SRT304 and SRT366. An accessory trim kit is required for this installation. Contact your authorized Wolf dealer for details.
Wolf pro ventilation hoods and hood liners can be used with all Wolf cooking appliances.
The chart below provides a reference of Wolf ventilation products typically used with Wolf cooking appliances.
COOKTOPS
Framed Induction Cooktops
Unframed Induction Cooktops
Framed Electric Cooktops
Unframed Electric Cooktops
Gas Cooktops
INTEGRATED MODULES
CT15I/S, CT15E/S and IM15/S
IG15/S, IS15/S and IF15/S
RANGES AND RANGETOPS
Dual Fuel Ranges
SRT304 and SRT366
All Other Sealed Burner Rangetops
Gas Ranges
Gas Rangetops
COOKTOP VENTILATION
CHIMNEY
HOODS
LOW-PROFILE
HOODS
DOWNDRAFT
SYSTEMS
WALL
HOODS
PRO VENTILATION
WALL CHIMNEY
HOODS
ISLAND
HOODS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
HOOD
LINERS
•
•
•
•
•
•
•
•
•
•
•
•
4
Selecting a Ventilation System 5 wolfappliance.com/specs
Selecting a Ventilation System
UPDRAFT OR DOWNDRAFT
The choice between updraft ventilation and downdraft ventilation will depend on several factors, most notably the cooking appliance being used as well as the type of installation and installation location. Updraft ventilation, or an overhead hood, will typically be a more effective ventilation option. Cooking vapors naturally rise, making it easier to collect and remove them from the cooking area.
Wolf downdraft systems provide another effective ventilation option. The telescopic downdraft chimney rises up from the countertop and draws cooking vapors away from the cooking surface. Downdraft ventilation is a great option in installations where an overhead hood is either not wanted or is not a viable option.
WIDTH GUIDELINES
For wall installations, the width of the hood should be at least as wide as the cooking surface. Where space is not restricted, a wider hood can be used to increase the capture area.
Island and peninsula installations require a greater capture area. Island hoods should exceed the width of the cooking surface by a minimum of 3" (76) on each side.
For downdraft ventilation systems, the width of the downdraft should match the width of the cooktop.
HOOD MOUNTING HEIGHT
Proper mounting height is very important. If a ventilation hood is mounted too low, access to the cooking surface may be restricted. If a hood is mounted too high, performance may be compromised.
For optimal performance, cooktop hoods should be mounted 24" (610) to 30" (762) from the bottom of the hood to the countertop. For optimal performance, pro hoods should be mounted 30" (762) to 36" (914) from the bottom of the hood to the countertop. Refer to individual specifications for each ventilation hood on pages 14–41.
CEILING HEIGHT
Before selecting a Wolf ventilation hood, check the installation site for adequate ceiling height, or any extra space that may remain after proper installation of the hood and cooking appliance. This can be determined by adding the floor-to-countertop height, plus the recommended hood mounting height (bottom of the hood to the countertop), plus the height of the hood. Refer to individual specifications for each ventilation hood on pages 14–41.
Excess ceiling height can be filled using an accessory flue extension (available for some cooktops hoods) or a stainless steel duct cover (pro hoods). The space can also be adjusted by raising or lowering your hood within the specified mounting height for your hood.
For additional ceiling height guidelines for cooktop wall and island hoods, refer to page 15.
Selecting a Ventilation System 6
Selecting a Ventilation System
COOKING STYLE
The appropriate airflow capacity is determined by the cooking space and cooking style. Greater exhaust capacity is required to handle moisture generated by boiling large pots of water or the grease and smoke from grilling or frying. Cooking with high heat or cooking aromatic foods may require additional CFM, and increasing the capture area with a hood that exceeds the cooking surface by 3" (76) on each side.
If the cooking surface is in an island or peninsula, a higher airflow capacity hood can provide better capture for cross currents, or if the hood needs to be mounted higher.
Downdraft ventilation systems are also a good alternative.
VENTILATION PERFORMANCE
Ventilation performance is measured in cubic feet per minute, or CFM. The higher the CFM, the greater the amount of air that is evacuated through the ventilation system. CFM are based on the cooking appliance output.
Wolf suggests 1 CFM per 100 Btu (.03 kW) .
The chart on page 10 provides CFM for all Wolf cooking appliances.
INTERNAL, IN-LINE OR REMOTE BLOWER
With the exception of some cooktop low-profile hoods and some downdrafts, Wolf ventilation products are shipped without the blower assembly. An internal, in-line or remote blower must be selected to accommodate the
Wolf cooking appliance.
The blower will vary in size, which is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run.
RECIRCULATING VENTILATION
Recirculating ventilation units are installed on top of a ventilation hood with no ductwork required. Recirculating units recycle the air through a charcoal filter and return it to the kitchen. Wolf recirculating units are for use with cooktop low-profile hoods with an internal blower and some pro wall hood models. Recirculating units should not be used with ranges or rangetops that contain a charbroiler or griddle. Refer to specifications for recirculating ventilation on pages 42–43.
IMPORTANT NOTE: This type of ventilation will not remove heat, moisture or combustion gases from the air. It will also be less effective in reducing odors and smoke.
Selecting a Ventilation System 7 wolfappliance.com/specs
Selecting a Ventilation System
DUCTWORK CONSIDERATIONS
IMPORTANT NOTE: Unless used in a recirculating application, Wolf ventilation hoods and downdrafts must be vented to the outside. Use only rigid metal ducting.
Typically, wall-mounted ventilation hoods can be vertical or horizontal discharge, while wall chimney hoods, island hoods and hood liners are vertical discharge only. For some wall hoods, an accessory horizontal discharge kit is required. In a horizontal discharge application, additional framework may be needed to accommodate the remote blower. Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles.
Depending on the specific installation, ductwork can run through the roof, external wall or eave. Ductwork through an eave requires an internal blower. Refer to individual specifications for each ventilation hood on pages 14–41.
A straight, short duct run with a limited number of elbows and transitions will allow the hood or downdraft to perform most efficiently. Wolf ventilation hoods will operate most efficiently when ductwork does not exceed 50' (15 m) in length, 40' (12 m) for downdrafts. Refer to the chart on page 9 to calculate total duct length.
IMPORTANT NOTE: Consult a qualified HVAC professional for specific installation and ductwork applications.
ELECTRICAL REQUIREMENTS
All Wolf ventilation products require a separate, grounded electrical supply. Refer to the electrical requirements for your specific ventilation product on pages 14–41. Locate the electrical supply within the shaded area shown in the installation illustration.
You must follow all National Electrical Code regulations.
In addition, be aware of local codes and ordinances when installing your service.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of operation.
CUSTOM HOOD APPLICATIONS
A custom decorative hood, used with pro hood liners, can be created out of wood, plaster, tile or metal to match virtually any design theme. The shape of the decorative hood is not critical as long as the hood liner fits completely inside the hood. The decorative hood and liner must fit together at the bottom edge in both width and depth. The height of the hood does not have to match the height of the liner. Interior dimensions of the decorative hood must exceed exterior dimensions of the liner. Refer to specifications for pro hood liners on pages 40–41.
Ventilation Made Easy 8
Ventilation Made Easy
After choosing your ventilation hood or downdraft, follow this three-step process to determine your blower needs:
Step 1) Determine the Duct Run
Step 2) Determine the CFM
Step 3) Select a Blower Assembly
Step 1: Determine the Duct Run
Check local codes.
Consult a qualified HVAC professional to ensure that all local codes are followed. Always refer to installation instructions for your specific Wolf ventilation product.
Minimize the duct run and number of elbows and transitions.
The length of the duct run and number of elbows and transitions can have a significant effect on ventilation performance. Keep the duct run as short as possible and limit the number of elbows and transitions.
Do not place elbows and transitions back-to-back.
Whenever possible, include a minimum 15" (381) straight ducting between elbows and transitions. Elbows and transitions placed too close to each other will cause a decrease in ventilation performance.
Use recommended duct sizes.
Depending on the specific ventilation product, Wolf recommends 8" (203) or 10" (254) ducting. Smaller duct sizes will significantly reduce ventilation performance. Refer to individual specifications for each ventilation product on pages 14–41.
Do not use flexible metal ducting.
Flexible metal ducting will increase air resistance and is not recommended by the
National Uniform Mechanical Code Standards.
Do not use butt joints.
Whenever possible, use male and female connections with the male end pointing in the direction of the airflow. Tightly tape joints to maximize ventilation performance.
Cold weather installations.
Cold weather installations may require an additional backdraft damper to minimize backward flow of cold air. It should be placed as close to the roof or wall cap as possible. All Wolf ventilation hoods, except low-profile wall hoods, come with a backdraft damper connected to the transition. Downdraft systems do not have a backdraft damper.
High altitudes.
Ventilation systems are less effective at altitudes above 5,000' (1524 m) . At these altitudes, you should estimate a 20%–25% reduction in CFM performance. Solutions include using a higher CFM blower and increasing the duct size.
Make-up air may be required.
Most newer homes have tightly sealed doors and windows. Make-up air may be needed to replace the air removed by the ventilation system. Many heating and air conditioning systems provide make-up air. Opening a window or door can be an option but may be less effective. Consult a qualified
HVAC professional for specific applications.
Recirculating ventilation.
Recirculating units recycle the air through a charcoal filter and return it to the kitchen.
This type of ventilation will not remove heat, moisture or combustion gases from the air. It will also be less effective in reducing odors and smoke. Recirculating units should only be used in applications where ductwork to the outside is not an option, and only if local codes allow it.
Refer to specifications for recirculating ventilation on pages 42–43.
Ventilation Made Easy 9 wolfappliance.com/specs
Step 1: Determine the Duct Run
Determining the equivalent duct length.
Determine the equivalent duct length for your installation using the equivalent duct lengths for commonly used ducting. Refer to the chart on the following page. The equivalent duct length is calculated as follows:
1) Compute the length of all straight ducting.
2) Compute the equivalent duct length of all elbows, transitions and caps.
3) Add equivalent lengths for all sections of the duct run.
EQUIVALENT DUCT LENGTHS
DUCTING
1' (.3 m) STRAIGHT DUCTING
90° ELBOW
45° ELBOW
ROUND TO RECTANGULAR TRANSITION
ROUND TO ROUND TRANSITION
ROOF CAP OR WALL CAP
SIZE
6" (152) round
8" (203) round
10" (254) round
3 1 /
4
" (83) x 10" (152)
6" (152) round
8" (203) round
10" (254) round
3 1 /
4
" (83) x 10" (152)
6" (152) round
8" (203) round
10" (254) round
3 1 /
4
" (83) x 10" (152)
6" (152) round to 3 1 /
4
" (83) x 10" (152)
8" (203) round to 3 1 /
4
" (83) x 10" (152)
3 1 /
4
" (83) x 10" (152) to 6" (152) round
3 1 /
4
" (83) x 10" (152) to 8" (203) round
6" (152) round to 8" (203) round
8" (203) round to 10" (254) round
8" (203) round to 6" (152) round
10" (254) round to 8" (203) round
6" (152) round
8" (203) round
10" (254) round
3 1 /
4
" (83) x 10" (152)
EQUIVALENT
LENGTH
4' (1.2 m)
1' (.3 m)
.3' (.1 m)
4' (1.2 m)
24' (7.3 m)
7' (2.1 m)
3' (.9 m)
12' (3.7 m)
12' (3.7 m)
4' (1.2 m)
2' (.6 m)
8' (2.4 m)
5' (1.5 m)
1' (.3 m)
12' (3.7 m)
16' (4.9 m)
4' (1.2 m)
1' (.3 m)
12' (3.7 m)
3' (.9 m)
60' (18.3 m)
20' (6.1 m)
9' (2.7 m)
60' (18.3 m)
TOTAL
QUANTITY TOTAL
Ventilation Made Easy 10
Step 2: Determine the CFM
The chart below provides CFM specific to the cooking appliance and ventilation system used. CFM are based on the cooking appliance output. Wolf suggests 1 CFM per
100 Btu (.03 kW) . Additional CFM may be required for long duct runs and ranges or rangetops with a charbroiler or griddle.
IMPORTANT NOTE: Specifing a blower with less CFM than listed in the chart below will result in decreased airflow and performance.
When determining the proper CFM for your installation, take into consideration the equivalent duct length calculated on the previous page.
IMPORTANT NOTE: Consult a qualified HVAC professional for specific applications.
WOLF PRODUCT CFM
MODEL
COOKTOPS AND MODULES
CT15I CT15E CT15G IG15* IS15* IF15* IM15
CT30I CT30IU* CT30E CT30EU* CT30G
CT36I CT36IU* CT36E CT36EU* CT36G
DUAL FUEL RANGES
DF304
DF366 DF364C DF364G
DF486C DF486G DF484CG DF484DG DF484F
DF606DG DF606F DF606CG DF604CF DF604GF
SEALED BURNER RANGETOPS
SRT304
SRT366
SRT364C SRT364G
SRT486C SRT486G SRT484CG SRT484DG SRT484F
GAS RANGES
R304
R366 R364C R364G
R488 R486C R486G R484CG R484DG R484F
R606DG R606F R606CG
GAS RANGETOPS
RT366 RT364C RT364G RT362F
RT488 RT486C RT486G RT484CG RT484DG RT484F
COOKTOP HOODS
CFM
215
450
600
DOWNDRAFTS
CFM
150
350
500
500
500
PRO HOODS
CFM
215
500
500
500
900
1100
1500
500
900
900
900
500
900
1100
1500
900
1100
*Downdraft systems are not recommended for use with these models.
CFM are based the cooking appliance output. Wolf suggests 1 CFM per 100 Btu (.03 kW) . Additional CFM may be required for long duct runs or ranges and rangetops with a charbroiler or griddle.
Ventilation Made Easy 11 wolfappliance.com/specs
Step 3: Select a Blower
WOLF BLOWER ASSEMBLIES
With the exception of some cooktop low-profile hoods and some downdrafts, Wolf ventilation products are shipped without the blower assembly. An internal, in-line or remote blower must be selected to accommodate the
Wolf cooking appliance. Wolf blower assemblies are available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
IMPORTANT NOTE: Wolf ventilation products must be installed only with a Wolf blower.
The chart on the following pages provides blower options for all cooktop and pro ventilation products.
Installation instructions shipped with each Wolf blower assembly provide detailed specifications.
INTERNAL BLOWERS
Internal blowers are mounted inside the hood canopy or downdraft blower box and provide the least disruption to the exterior of the home.
Internal blowers are available for all Wolf cooktop and pro ventilation products. Refer to specifications for Wolf internal blowers on pages 44–48.
IN-LINE BLOWERS
In-line blowers are mounted between the hood and the exterior of the home. Ductwork runs from the hood and connects to the blower. More ductwork is attached to the other side of the blower and runs to the exterior of the home. This is a great option for those who do not want the blower mounted inside the hood but cannot, or prefer not to mount a remote blower on the exterior of the home.
In-line blowers are available for all Wolf cooktop and pro ventilation products. Refer to specifications for Wolf in-line blowers on pages 49–50 with additional planning information on pages 58–59.
REMOTE BLOWERS
Remote blowers can be mounted on the roof or, in some cases, on an exterior wall. A remote-mounted blower will minimize the amount of blower noise but will not eliminate the noise completely.
Some blower noise is considered normal while the blower is operational. If noise is a concern, a remote blower is recommended. To reduce noise further for remote blower applications, an attenuator may be necessary.
Remote blowers are available for all Wolf cooktop and pro ventilation products. Refer to specifications for Wolf remote blowers on pages 51–57 with additional planning information on pages 60–62.
Ventilation Made Easy
Step 3: Select a Blower
CFM
BLOWER
COOKTOP HOODS
CTWH30
CTWH36 IH4227
COOKTOP LOW-PROFILE HOODS
CTEWH36 CTEWH45
DOWNDRAFTS
DD30R DD36R DD45R
PRO LOW-PROFILE WALL HOODS
PW302210 PW362210
PW422210 PW482210
PRO 24" (610) WALL HOODS
PW302418 PW362418 PW422418
PW482418 PW542418
PW602418 PW662418
PRO 27" (686) WALL HOODS
PW302718 PW362718 PW422718
PW482718 PW542718
PW602718 PW662718
PRO WALL CHIMNEY HOODS
PWC362418 PWC422418
PWC482418 PWC542418
PRO ISLAND HOODS
PI363418 PI423418
PI543418
PI663418
PRO HOOD LINERS
PL342212 PL402212
PL462212
PL522212
PL582212
300*
814419
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
450*
814420
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
INTERNAL
500
810991
600
814421
•
•
•
•
•
•
•
•
•
900
814422
•
•
•
•
•
•
•
•
•
•
•
•
1200
814423
•
•
•
•
•
•
•
•
•
•
•
12
Ventilation Made Easy 13 wolfappliance.com/specs
Step 3: Select a Blower
CFM
BLOWER
COOKTOP HOODS
CTWH30
CTWH36 IH4227
COOKTOP LOW-PROFILE HOODS
CTEWH36 CTEWH45
DOWNDRAFTS
DD30R DD36R DD45R
PRO LOW-PROFILE WALL HOODS
PW302210 PW362210
PW422210 PW482210
PRO 24" (610) WALL HOODS
PW302418
PW362418 PW422418 PW482418 PW542418
PW602418 PW662418
PRO 27" (686) WALL HOODS
PW302718
PW362718 PW422718 PW482718 PW542718
PW602718 PW662718
PRO WALL CHIMNEY HOODS
PWC362418 PWC422418
PWC482418 PWC542418
PRO ISLAND HOODS
PI363418 PI423418
PI543418
PI663418
PRO HOOD LINERS
PL342212 PL402212
PL462212
PL522212
PL582212
600
808331
IN-LINE
1100
808332
•
•
•
•
•
•
•
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
600
801640
•
•
•
REMOTE
900
801641
1200
801642
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1500
804701
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Wolf Cooktop Ventilation 14
Wolf Cooktop Ventilation
COOKTOP CHIMNEY HOODS
Wolf cooktop chimney hoods are crafted of seamless stainless steel. Chimney wall and island hoods have a telescopic flue which allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension for 10' (3 m) ceilings is available as a sales accessory.
Wolf cooktop chimney hoods can be used with all Wolf cooktops and integrated modules.
COOKTOP LOW-PROFILE HOODS
Wolf cooktop low-profile hoods are crafted of stainless steel with a black glass control panel. Low-profile wall and island hoods have a telescopic chimney flue which allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. Wall and island hoods are available with an internal blower, or some wall hood models have in-line and remote blower options.
Wolf cooktop low-profile hoods can be used with all Wolf cooktops and integrated modules.
DOWNDRAFT SYSTEMS
Wolf downdraft ventilation systems are crafted of stainless steel. Downdrafts are available with an internal blower, or some models have in-line and remote blower options.
Wolf downdraft systems can be used with Wolf framed induction, framed electric and gas cooktops and some integrated modules. A downdraft can be used with sealed burner rangetop models SRT304 and SRT366. An accessory trim kit is required for this installation. Contact your authorized Wolf dealer for details.
IMPORTANT NOTE: Wolf downdraft systems cannot be installed with unframed induction and unframed electric cooktops, and steamer and fryer modules. They are not recommended for use with the grill module.
Refer to specifications for individual cooktop hoods and downdraft systems on the following pages.
Downdraft systems.
Cooktop chimney hoods.
Cooktop low-profile hoods.
Cooktop Ventilation Widths
WIDTH
Chimney Wall Hoods
Chimney Island Hoods
Low-Profile Wall Hoods
Low-Profile Island Hoods
Downdrafts
30" (762)
•
•
•
36" (914)
•
42" (1067) 45" (1143) 48" (1219) 54" (1372) 60" (1524) 66" (1676)
•
• •
•
• •
Wolf Cooktop Ventilation 15 wolfappliance.com/specs
Wolf Cooktop Ventilation Hoods
HOOD PLACEMENT
Installation of the cooktop wall or island hood should be
24" (610) to 30" (762) from the bottom of the hood to the countertop. To determine placement of the cooktop hood, you must calculate the height of the telescopic chimney flue. The minimum and maximum flue extension for each cooktop hood is listed in the charts below.
IMPORTANT NOTE: Both sections of the telescopic chimney flue must be installed in order for the chimney to be lifted for service.
CALCULATE CHIMNEY FLUE HEIGHT
A) Height from finished floor to finished ceiling. 8' (2.4 m) or 9' (2.7 m) ceilings are typical.
B) Height from finished floor to countertop. A 36" (914) countertop height is standard.
C) Hood mounting height (bottom of hood to countertop).
Dimension C must be between 24" (610) and 30" (762) .
8' (2.4 m) ceilings may not allow the maximum 30" (762) hood mounting height.
D) Calculate chimney flue height: D = A – (B + C).
Dimension D must be between the minimum and maximum flue extension listed in the charts. Refer to the illustration below.
Cooktop Chimney Hoods
FLUE EXTENSION
CTWH30
CTWH36
IH4227
MINIMUM
30 1 /
2
" (775)
32 5 /
8
" (829)
33 1 /
2
" (851)
Cooktop Low-Profile Hoods
FLUE EXTENSION
CTEWH30I
CTEWH36(I)
CTEWH45(I)
CTEIH42I
MINIMUM
29 1 /
8
" (740)
29 1 /
8
" (740)
29 1 /
8
" (740)
28 1 /
4
" (718)
MAXIMUM
48 1 /
2
" (1232)
50 7 /
8
" (1292)
47" (1194)
MAXIMUM
41 1 /
2
" (1054)
41 1 /
2
" (1054)
41 1 /
2
" (1054)
41 1 /
2
" (1054)
D MINIMUM
FLUE
EXTENSION
A C
B
Cooktop hood placement.
Wolf Cooktop Ventilation 16
Cooktop Chimney Wall Hood
Model Options
MODEL
CTWH30
CTWH36
WIDTH
30" (762)
35
1
/
2
" (902)
WEIGHT
85 lbs (39 kg)
100 lbs (45 kg)
HEIGHT
21"
(533)
WIDTH
FEATURES
• Heavy-duty, stainless steel seamless construction.
• Internal, in-line and remote blower options.
• Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
• Front-mounted controls with LED indicator and threespeed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with three settings.
• Delay-off feature to automatically turn unit off.
• Filter clean timer lets you know when filters need cleaning.
• Stainless steel filter cover with dishwasher-safe aluminum mesh filter.
• Transition with backdraft damper.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• Flue extension to accommodate 10' (3 m) ceilings.
• 30" (762) high stainless steel wall shield.
• 8" (203) to 10" (254) round transition.
Specifications
COOKTOP VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Telescoping Height
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Wall
Stainless Steel
30" (762) and 35 1 /
2
" (902)
(CTWH30)
(CTWH36)
6 7 /
8
" (175)
9 1 /
4
" (235)
21" (533)
(CTWH30)
(CTWH36)
30 1 /
2
" (775)— 48 1 /
2
" (1232)
32 5 /
8
" (829)— 50 7 /
8
" (1292)
24" (610) to 30" (762) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two or three T4, 12 V, 20 W bulbs (included)
Vertical
8" (203) Round
Blower Options
CFM
CTWH30
CTWH36
300*
•
•
450*
•
•
INTERNAL
500 600
•
•
900
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
IN-LINE
600
•
•
1100
•
•
600
•
•
REMOTE
900
•
•
1200
•
•
1500
•
•
Wolf Cooktop Ventilation
Cooktop Chimney Wall Hood
INSTALLATION
17 wolfappliance.com/specs
18"
(457)
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
9" (229)
E
6"
(152)
4" (102)
19
1
/ 8 "
(486)
6
7
/ 8 " (175)
OR
9 1 /
4
"
(235)
30" (762) OR 35
1
/ 2 " (902)
HOOD WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
30 1 / 2 " (775) TO
48 1 / 2 " (1232)
OR
32 5 / 8 " (829) TO
50 7 / 8 " (1292)
TELESCOPING
HOOD HEIGHT
DUCTWORK
INSTALLATION
THROUGH
WALL
12"
(305)
21" (535)
HOOD DEPTH
24"
(610) TO
30"
(762)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: 8' (2.4 m) ceilings can not accommodate 30" (762) from bottom of hood to countertop. Based on 36" (914) countertop height, an 8' (2.4 m) ceiling will allow for a maximum 29
1
/
2
" (749) for CTWH30 and 27 1 /
4
" (692) for CTWH36, from bottom of hood to countertop.
Wolf Cooktop Ventilation
Cooktop Chimney Island Hood
Model Options
MODEL
IH4227
WIDTH
42" (1067)
WEIGHT
110 lbs (50 kg)
9 1 /
4
"
(235)
27"
(686)
42"
(1067)
FEATURES
• Heavy-duty, stainless steel seamless construction.
• Internal, in-line and remote blower options.
• Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
• Front-mounted controls with LED indicator and threespeed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with three settings.
• Delay-off feature to automatically turn unit off.
• Filter clean timer lets you know when filters need cleaning.
• Stainless steel filter cover with dishwasher-safe aluminum mesh filter.
• Transition with backdraft damper.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• Flue extension to accommodate 10' (3 m) ceilings.
• 8" (203) to 10" (254) round transition.
Specifications
COOKTOP VENTILATION
Installation Type
Exterior Finish
Width
Height
Depth
Telescoping Height
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Island
Stainless Steel
42" (1067)
9 1 /
4
" (235)
27" (686)
33 1 /
2
" (851) to 47" (1194)
24" (610) to 30" (762) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Four T4, 12 V, 20 W bulbs
(included)
Vertical
8" (203) Round
Blower Options
CFM
IH4227
300*
•
450*
•
INTERNAL
500 600
•
900
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
IN-LINE
600
•
1100
•
600
•
REMOTE
900
•
1200
•
1500
•
18
Wolf Cooktop Ventilation 19 wolfappliance.com/specs
Cooktop Chimney Island Hood
INSTALLATION
LOCATE ELECTRICAL
THROUGH TOP OF HOOD
18" (457)
42" (1067)
HOOD WIDTH
19 1 /
4
"
(489)
9 1 /
4
"
(235)
DUCTWORK INSTALLATION
THROUGH ROOF
33 1 / 2 " (851)
TO 47" (1194)
TELESCOPING
HOOD HEIGHT
24"
(610) TO
30"
(762)
BOTTOM OF
HOOD TO
COUNTERTOP
12"
(305)
27" (686)
HOOD DEPTH
DUCTWORK
INSTALLATION
THROUGH
EAVE—
INTERNAL
BLOWER
Wolf Cooktop Ventilation
Cooktop Low-Profile Wall Hood
3 1 /
8
"
(79)
Model Options
MODEL
CTEWH30I*
CTEWH36
CTEWH36I*
CTEWH45
CTEWH45I*
*Internal blower included.
WIDTH
30" (762)
36" (914)
36" (914)
45" (1143)
45" (1143)
WEIGHT
53 lbs (24 kg)
51 lbs (23 kg)
57 lbs (26 kg)
55 lbs (25 kg)
62 lbs (28 kg)
17 3 /
4
"
(451)
WIDTH
FEATURES
• Heavy-duty, stainless steel seamless construction.
• Internal, in-line and remote blower options.
• Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
• Front-mounted electronic controls with digital indicator and four-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with three settings.
• Delay-off feature to automatically turn unit off.
• Filter clean indicator.
• Stainless steel filter cover with dishwasher-safe aluminum mesh filter.
• Transition with backdraft damper.
ACCESSORIES
• In-line and remote blowers for CTEWH36 and CTEWH45
(refer to chart below).
• 30" (762) high stainless steel wall shield.
• Recirculating kit and filter for non-ducted applications
(internal blower models).
Specifications
COOKTOP VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Telescoping Height
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Wall
Stainless Steel
30" (762), 36" (914) and 45" (1143)
3 1 /
8
" (79)
17 3 /
4
" (451)
29 1 /
8
" (740) to 41 1 /
2
" (1054)
24" (610) to 30" (762) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Four T4, 12 V, 20 W bulbs
(included)
Vertical
6" (152) Round
Blower Options
CFM
CTEWH30I CTEWH36I CTEWH45I
CTEWH36 CTEWH45
300 450
INTERNAL
500 600
Included
900 1200
IN-LINE
600 1100 600
REMOTE
900 1200 1500
• •
20
Wolf Cooktop Ventilation 21 wolfappliance.com/specs
Cooktop Low-Profile Wall Hood
INSTALLATION
9 7 /
8
"
(251)
E
LOCATE
ELECTRICAL
WITHIN
SHADED
AREA
5"
(127)
15"
(381)
30"
(762),
36"
(914)
OR 45" (1143)
HOOD WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
10
7
/ 8 "
(276)
8' (2.4 m)
TO
9' (2.7 m)
CEILING
HEIGHT
TO
29
41
1
1
/ 8 " (740)
/ 2 " (1054)
TELESCOPING
HOOD HEIGHT
DUCTWORK
INSTALLATION
20
1
/ 8 "
(511)
THROUGH
WALL
3
1
/ 8 " (79)
17
3
/ 4 " (451)
HOOD DEPTH
24"
(610) TO
30"
(762)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: For non-ducted applications with a recirculating kit, the telescoping hood height is 31" (788) to 48 3 /
4
" (1238) .
Wolf Cooktop Ventilation
Cooktop Low-Profile Island Hood
Model Options
MODEL
CTEIH42I*
*Internal blower included.
WIDTH
42" (1067)
WEIGHT
92 lbs (42 kg)
3 1 /
8
"
(79)
21 5 /
8
"
(459)
42"
(1067)
FEATURES
• Heavy-duty, stainless steel seamless construction.
• Internal blower included.
• Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
• Front-mounted electronic controls with digital indicator and four-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with three settings.
• Delay-off feature to automatically turn unit off.
• Filter clean indicator.
• Stainless steel filter cover with dishwasher-safe aluminum mesh filter.
• Transition with backdraft damper.
ACCESSORIES
• Recirculating kit and filter for non-ducted applications.
Specifications
COOKTOP VENTILATION
Installation Type
Exterior Finish
Width
Height
Depth
Telescoping Height
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Island
Stainless Steel
42" (1067)
3 1 /
8
" (79)
21 5 /
8
" (459)
28 3 /
8
" (721) to 40" (1016)
24" (610) to 30" (762) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Four T4, 12 V, 20 W bulbs
(included)
Vertical
6" (152) Round
22
Blower Options
CFM
CTEIH42I
300 450
INTERNAL
500 600
Included
900 1200
IN-LINE
600 1100 600
REMOTE
900 1200 1500
Wolf Cooktop Ventilation 23 wolfappliance.com/specs
Cooktop Low-Profile Island Hood
INSTALLATION
LOCATE ELECTRICAL
THROUGH TOP OF HOOD
11
3
/ 4 "
(298)
42" (1067)
HOOD WIDTH
22
7
/ 8 "
(581)
3
1
/ 8 " (79)
DUCTWORK INSTALLATION
THROUGH ROOF
28 3 / 8 " (721)
TO 40" (1016)
TELESCOPING
HOOD HEIGHT
9
7
/ 8 "
(251)
DUCTWORK
INSTALLATION
THROUGH
EAVE—
INTERNAL
BLOWER
24"
(610) TO
30"
(762)
BOTTOM OF
HOOD TO
COUNTERTOP
21
5
/ 8 " (549)
HOOD DEPTH
8' (2.4 m)
TO
9' (2.7 m)
CEILING
HEIGHT
NOTE: For non-ducted applications with a recirculating kit, the telescoping hood height is 30 3 /
4
" (781) to 40" (1016) .
Wolf Cooktop Ventilation 24
Downdraft Ventilation System
9 1 /
8
"
(232)
2 3 /
8
"
(60)
WIDTH
FEATURES
• Crafted of heavy-duty stainless steel.
• Downdraft chimney lowers beneath countertop when not in use.
• Stainless steel top trim and remote-mounted control module with LED indicators.
• Three-speed blower control.
• Delay-off feature to automatically turn unit off.
• Filter clean timer lets you know when filters need cleaning.
• Dishwasher-safe aluminum mesh filters with stainless steel filter covers.
ACCESSORIES
• In-line and remote blowers for DD30R, DD36R and
DD45R (refer to chart below).
• Support bracket for installation with two integrated modules (DD30).
• Trim kit for installation with sealed burner rangetop
(DD30 and DD36).
• Transitions to round ductwork.
Model Options
MODEL
DD30I*
DD30R
DD36I*
DD36R
DD45I*
DD45R
*Internal blower included.
Specifications
COOKTOP VENTILATION
Installation Type
Exterior Finish
Top Trim Widths
Chimney Widths
Height
Top Trim Depth
Chimney Depth
Electrical Supply
Power Cord
Discharge
Duct Size
WIDTH
30" (762)
30" (762)
36" (914)
36" (914)
45 1 /
2
" (1156)
45 1 /
2
" (1156)
WEIGHT
90 lbs (41 kg)
75 lbs (34 kg)
95 lbs (43 kg)
80 lbs (36 kg)
100 lbs (45 kg)
85 lbs (39 kg)
Downdraft
Stainless Steel
30" (762), 36" (914) and 45 1 /
2
" (1156)
26 1 /
4
" (667), 32 1 /
4
" (819) and
41 1 /
4
" (1048)
9 1 /
8
" (232) above countertop
2 3 /
8
" (60)
1 1 /
2
" (38)
120 V AC, 60 Hz, 15 amp dedicated circuit
2
1
/
2
' (.8 m) 3-prong
Adjustable
( I ) 3 1 /
4
" (83) x 10" (254)
(R) 3 1 /
4
" (83) x 14" (356)
Blower Options
CFM
DD30I DD36I DD45I
DD30R DD36R DD45R
300* 450*
INTERNAL
500 600
Included
•
900
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
IN-LINE
600 1100 600
•
REMOTE
900 1200 1500
• • •
Wolf Cooktop Ventilation 25 wolfappliance.com/specs
Downdraft Ventilation System
INSTALLATION WITH COOKTOP INSTALLATION WITH SEALED BURNER RANGETOP
25 1/8 "
(638) min
FLAT
COUNTERTOP
27" (686), 33" (838) OR 42" (1067)
DOWNDRAFT CUT-OUT
3" (76) min
TO CONTROL
MODULE
COOKTOP CUT-OUT
WIDTH
2 1/2 " (64) min
COUNTERTOP CUT-OUT (TOP VIEW)
2 3/4 "
(70)
19 1/4 "
(489)
30" (762) rec
FLAT
COUNTERTOP
27"
(686) OR
33"
(838)
DOWNDRAFT CUT-OUT
3" (76) min
TO CONTROL
MODULE
30"
(762) OR
36"
(914)
WIDTH OF RANGETOP
COUNTERTOP CUT-OUT (TOP VIEW)
2 3/4 "
(70)
24"
(610) min*
2 1/2 "
(64) min
EDGE OF
COOKTOP
TO WALL
25 1/8 "
(638) min
FLAT COUNTERTOP
2 1/2 "
(64) min
EDGE OF
RANGETOP
TO WALL
30" (762) rec
FLAT COUNTERTOP
7 11/16 " (197)
19" (483)
PLATFORM DEPTH
7 1/2 "
(191)
29 5/16 "
(745)
29 5/16 "
(745)
SIDE VIEW
7 1/8 "
(181)
24" min (610)
CABINET DEPTH
NOTE: To install a downdraft with a Wolf cooktop, you must allow for a minimum 25 1 /
8
" (638) flat counter space from front to back. A countertop with a raised lip or backsplash may not allow enough space for proper installation.
Location of the electrical outlet must be within reach of the power cord which is located midway, top and bottom, on the right side of the downdraft. Unless oversized cabinets are used, the outlet cannot be located on the back wall of the cabinet, but may be placed in adjacent cabinetry.
7 1/8 "
(181)
27 1/4 " (692) min
CABINET DEPTH
SIDE VIEW
*Additional depth may be required if rangetop is to be installed flush with cabinet face.
Installation of the remote-mounted control module must be within 10' (3 m) of the downdraft assembly and a minimum of
4" (102) from the outer edge of cooktop element or burner.
Wolf Cooktop Ventilation 26
Downdraft Ventilation System
SIDE DISCHARGE
COUNTERTOP
CUT-OUT
B
A
RIGHT
DISCHARGE
LOCATION
C
LEFT
DISCHARGE
LOCATION
DISCHARGE CUT-OUT:
10 1/4 "
(260) x
3 1/2 "
(89) INTERNAL BLOWER
14 1/4 " (362) x 3 1/2 " (89) IN-LINE OR REMOTE
BOTTOM DISCHARGE
COUNTERTOP
CUT-OUT
ADJUSTMENT
B
ADJUSTMENT
A
C
BOTTOM DISCHARGE
LOCATION
DISCHARGE CUT-OUT:
10 1/4 "
(260) x
3 1/2 "
(89) INTERNAL BLOWER
14 1/4 " (362) x 3 1/2 " (89) IN-LINE OR REMOTE
Side Discharge
BLOWER
Dimension A
Dimension B
Dimension C
INTERNAL
22 1 /
8
" (562)
16 3 /
8
" (416)
5 1 /
2
" (140)
IN-LINE / REMOTE
19" (483)
21 1 /
2
" (546)
4 1 /
4
" (108)
NOTE: Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles. Three different discharge locations (left side, right side or bottom) allow side-to-side adjustment for accurate alignment of ductwork.
Bottom Discharge
BLOWER
Adjustment A
Adjustment B
Dimension C
INTERNAL IN-LINE / REMOTE
N/A 5" (127) MAX
1" (25) TO 7" (178) 2 1 /
2
" (165) MAX
5 1 /
2
" (140) 4 1 /
4
" (108)
Wolf Cooktop Ventilation
Downdraft Ventilation System
DUCTWORK OPTIONS
WALL CAP
12" (305) MIN
TO
GROUND
Internal blower through wall.
WALL CAP
12"
(305) MIN
TO
GROUND
Internal blower through wall.
10" (254)
ROUND
DUCT
REMOTE
BLOWER
Remote blower through roof.
REMOTE
BLOWER
10" (254)
ROUND
DUCT
12" (305)
MIN TO
GROUND
Remote blower through wall.
27 wolfappliance.com/specs
Wolf Pro Ventilation 28
Wolf Pro Ventilation
Wolf pro ventilation is available in a wide variety of styles and sizes to meet virtually any application, including hood liners for installation with a custom decorative hood. Wolf pro ventilation hoods and hood liners can be used with all
Wolf cooking appliances. Refer to specifications for individual pro ventilation products on the following pages.
Installation of pro hoods and hood liners should be
30" (762) to 36" (914) from the bottom of the hood to the countertop.
PRO WALL HOODS
Pro wall ventilation hoods are crafted of seamless stainless steel and available in three styles. Low-profile hoods are 22" (559) deep and 10" (254) high, while the pro 24"
(610) and 27" (686) deep wall hoods are 18" (381) high.
All three styles come in a variety of widths. Refer to the chart on the following page. Pro 27" (686) deep wall hoods feature heat lamps.
IMPORTANT NOTE: For optimal performance, a pro
27" (686) deep wall hood should be used with ranges and rangetops that contain a charbroiler or griddle.
PRO WALL CHIMNEY HOODS
Pro wall chimney hoods are crafted of seamless stainless steel. Optional duct covers in a variety of heights are available to complete the chimney design.
PRO ISLAND HOODS
Pro island hoods are crafted of seamless stainless steel.
The width of the island hood should exceed the width of the cooking surface by a minimum of 3" (76) on each side.
PRO HOOD LINERS
Pro ventilation hood liners are available to accommodate custom decorative hoods. The custom decorative hood can be created out of wood, plaster, tile or metal to match virtually any design theme.
The shape of the decorative hood is not critical as long as the hood liner fits completely inside the hood. The decorative hood and liner must fit together at the bottom edge in both width and depth. The height of the hood does not have to match the height of the liner. Interior dimensions of the decorative hood must exceed exterior dimensions of the liner.
Pro island hoods.
Pro hood liners.
Pro wall hoods.
Pro wall chimney hoods.
Wolf Pro Ventilation 29 wolfappliance.com/specs
Wolf Pro Ventilation
Pro Ventilation Widths
WIDTH
Low-Profile Wall Hoods
24" Deep Wall Hoods
27" Deep Wall Hoods
Wall Chimney Hoods
Island Hoods
Hood Liners
30" (762)
•
•
•
36" (914)
•
•
•
•
•
•
42" (1067)
•
•
•
•
•
•
45" (1143) 48" (1219)
•
•
•
•
•
54" (1372) 60" (1524) 66" (1676)
•
•
•
•
•
•
•
•
•
•
•
Wolf Pro Ventilation
Pro Low-Profile Wall Hood
10"
(254)
22"
(559)
WIDTH
Model Options
MODEL
PW302210
PW362210
PW422210
PW482210
WIDTH
30" (762)
36" (914)
42" (1067)
48" (1219)
WEIGHT
39 lbs (18 kg)
44 lbs (20 kg)
50 lbs (23 kg)
55 lbs (25 kg)
FEATURES
• Heavy-duty, brushed stainless steel exterior with enclosed liner.
• Internal, in-line and remote blower options.
• Welded seams, hemmed edges and hand-finished craftsmanship.
• Recessed easy-access controls.
• Infinite-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with two settings.
• Removable, dishwasher-safe stainless steel baffle filters.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• 38" (965) high stainless steel backsplash with or without warming racks.
• 6" (152) , 12" (305) , 18" (457) , 24" (610) and 30" (762) high stainless steel duct covers.
• Recirculating kit and filter for non-ducted applications—
30" (762) and 36" (914) wide models with internal blower.
Specifications
PRO VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Transition
Wall
Stainless Steel
30" (762), 36" (914), 42" (1067) and 48" (1219)
10" (254)
22" (559)
30" (762) to 36" (914) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two or three 50 W, 120 V par 20 bulbs (included)
Vertical or Horizontal
10" (254) Round
3 1 /
4
" (83) x 14" (356) cut-out
(transition included with internal blower)
Blower Options
CFM
PW302210 PW362210
PW422210 PW482210
300 450
INTERNAL
500
•
600 900 1200 600
•
•
IN-LINE
1100 600
•
•
900
•
•
REMOTE
1200 1500
30
Wolf Pro Ventilation
Pro Low-Profile Wall Hood
INSTALLATION
31 wolfappliance.com/specs
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
(127)
30"
(762),
36"
(914)
42" (1067) OR 48" (1219)
HOOD WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
10"
(254)
HOOD HEIGHT
4" (102)
12"
(305)
22" (559)
HOOD DEPTH
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: Pro low-profile wall hoods come standard with vertical or horizontal discharge.
Wolf Pro Ventilation
Pro 24" Deep Wall Hood
18"
(457)
24"
(610)
WIDTH
Model Options
MODEL
PW302418
PW362418
PW422418
PW482418
PW542418
PW602418
PW662418
FEATURES
• Heavy-duty, brushed stainless steel exterior with enclosed liner.
• Internal, in-line and remote blower options.
• Hand-finished, welded seams and hemmed edges.
• Recessed easy-access controls.
• Infinite-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with two settings.
• Removable, dishwasher-safe stainless steel baffle filters.
• Transition with backdraft damper.
• Horizontal discharge with accessory kit.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• 38" (965) high stainless steel backsplash with or without warming racks.
• 6" (152) , 12" (305) , 18" (457) , 24" (610) and 30" (762) high stainless steel duct covers.
• Horizontal discharge kit.
• Recirculating kit and filter for non-ducted applications—
30" (762) and 36" (914) wide models with internal blower.
Specifications
PRO VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Transition
WIDTH
30" (762)
36" (914)
42" (1067)
48" (1219)
54" (1372)
60" (1524)
66" (1676)
WEIGHT
67 lbs (30 kg)
78 lbs (35 kg)
86 lbs (39 kg)
94 lbs (43 kg)
106 lbs (48 kg)
116 lbs (53 kg)
126 lbs (57 kg)
Wall
Stainless Steel
30" (762), 36" (914), 42" (1067)
48" (1219), 54" (1372), 60" (1524) and 66" (1676)
18" (457)
24" (610)
30" (762) to 36" (914) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two or three 50 W, 120 V par 20 bulbs (included)
Vertical or Horizontal
(requires horizontal discharge kit)
10" (254) Round
Rectangle to 10" (254) round,
9" (229) height (included)
Blower Options
CFM
PW302418
PW362418
PW422418
PW482418 PW542418
PW602418 PW662418
300*
•
•
•
•
•
450*
•
•
•
•
•
INTERNAL
500 600
•
•
•
900
•
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
•
IN-LINE
600
•
1100
•
•
•
•
•
600
•
REMOTE
900
•
•
•
•
1200
•
•
•
•
•
1500
•
•
•
•
•
32
Wolf Pro Ventilation
Pro 24" Deep Wall Hood
INSTALLATION
33 wolfappliance.com/specs
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
(127)
30"
(762),
36"
(914),
42"
(1067)
48" (1219), 54" (1372)
60"
(1524) OR
66"
(1676)
HOOD WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
12"
(305)
18" (457)
HOOD HEIGHT
4" (102)
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
24" (610)
HOOD DEPTH
NOTE: Alternative horizontal discharge requires accessory kit.
Refer to instructions provided with kit for detailed specifications.
Wolf Pro Ventilation
Pro 27" Deep Wall Hood
18"
(457)
27"
(686)
WIDTH
Model Options
MODEL
PW302718
PW362718
PW422718
PW482718
PW542718
PW602718
PW662718
FEATURES
• Heavy-duty, brushed stainless steel exterior with enclosed liner.
• Internal, in-line and remote blower options.
• Hand-finished, welded seams and hemmed edges.
• Recessed easy-access controls.
• Infinite-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with two settings.
• Heat lamp receptacles (bulbs not included).
• Removable, dishwasher-safe stainless steel baffle filters.
• Transition with backdraft damper.
• Horizontal discharge with accessory kit.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• 38" (965) high stainless steel backsplash with or without warming racks.
• 6" (152) , 12" (305) , 18" (457) , 24" (610) and 30" (762) high stainless steel duct covers.
• Horizontal discharge kit.
Specifications
PRO VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Installation Height
Electrical Supply
Halogen Bulbs
Heat Lamp Bulbs
Discharge
Duct Size
Transition
WIDTH
30" (762)
36" (914)
42" (1067)
48" (1219)
54" (1372)
60" (1524)
66" (1676)
WEIGHT
69 lbs (31 kg)
80 lbs (36 kg)
88 lbs (40 kg)
96 lbs (44 kg)
108 lbs (49 kg)
118 lbs (54 kg)
128 lbs (58 kg)
Wall
Stainless Steel
30" (762), 36" (914), 42" (1067)
48" (1219), 54" (1372), 60" (1524) and 66" (1676)
18" (457)
27" (686)
30" (762) to 36" (914) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two or three 50 W, 120 V par 20 bulbs (included)
Two R40 250 W, 120 V, 60 Hz infrared bulbs (not included)
Vertical or Horizontal
(requires horizontal discharge kit)
10" (254) Round
Rectangle to 10" (254) round,
9" (229) height (included)
Blower Options
CFM
PW302718
PW362718
PW422718
PW482718 PW542718
PW602718 PW662718
300*
•
•
•
•
•
450*
•
•
•
•
•
INTERNAL
500 600
•
•
•
900
•
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
•
IN-LINE
600
•
1100
•
•
•
•
•
600
•
REMOTE
900
•
•
•
•
1200
•
•
•
•
•
1500
•
•
•
•
•
34
Wolf Pro Ventilation
Pro 27" Deep Wall Hood
INSTALLATION
35 wolfappliance.com/specs
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
(127)
30"
(762),
36"
(914),
42"
(1067)
48" (1219), 54" (1372)
60" (1524) OR 66" (1676)
HOOD WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
18" (457)
HOOD HEIGHT
4" (102)
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
27" (686)
HOOD DEPTH
12"
(305)
NOTE: Alternative horizontal discharge requires accessory kit.
Refer to instructions provided with kit for detailed specifications.
Wolf Pro Ventilation
Pro Wall Chimney Hood
18"
(457)
WIDTH
24"
(610)
Model Options
MODEL
PWC362418
PWC422418
PWC482418
PWC542418
WIDTH
36" (914)
42" (1067)
48" (1219)
54" (1372)
WEIGHT
78 lbs (35 kg)
86 lbs (39 kg)
94 lbs (43 kg)
106 lbs (48 kg)
FEATURES
• Install with accessory duct cover for chimney-style hood.
• Heavy-duty, brushed stainless steel exterior with enclosed liner.
• Internal, in-line and remote blower options.
• Welded seams, hemmed edges and hand-finished craftsmanship.
• Recessed easy-access controls.
• Infinite-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with two settings.
• Removable, dishwasher-safe stainless steel baffle filters.
• Transition with backdraft damper.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• 38" (965) high stainless steel backsplash with or without warming racks.
• 6" (152) , 12" (305) , 18" (457) , 24" (610) high stainless steel duct covers.
Specifications
PRO VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Transition
Wall
Stainless Steel
36" (914), 42" (1067), 48" (1219) and 54" (1372)
18" (457)
24" (610)
30" (762) to 36" (914) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two or three 50 W, 120 V par 20 bulbs (included)
Vertical
10" (254) Round
Rectangle to 10" (254) round,
7" (178) height (included)
Blower Options
CFM
PWC362418 PWC422418
PWC482418 PWC542418
300*
•
•
450*
•
•
INTERNAL
500 600
•
900
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
IN-LINE
600 1100
•
•
600
REMOTE
900
•
•
1200
•
•
1500
•
•
36
Wolf Pro Ventilation
Pro Wall Chimney Hood
INSTALLATION
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
6"
(152)
5"
(127)
E
WIDTH MINUS
18" (457)
36"
(914),
42"
(1067)
48" (1219) OR 54" (1372)
HOOD WIDTH
37 wolfappliance.com/specs
DUCTWORK INSTALLATION
THROUGH ROOF
OPTIONAL
DUCT COVER
18" (457)
HOOD HEIGHT
4" (102)
13
1
/ 2 "
(343)
24" (610)
HOOD DEPTH
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
Wolf Pro Ventilation
Pro Island Hood
18"
(457)
34"
(864)
WIDTH
Model Options
MODEL
PI362418
PI422418
PI542418
PI662418
WIDTH
36" (914)
42" (1067)
54" (1372)
66" (1676)
WEIGHT
95 lbs (43 kg)
103 lbs (47 kg)
128 lbs (58 kg)
168 lbs (76 kg)
FEATURES
• Heavy-duty, brushed stainless steel exterior with enclosed liner.
• Internal, in-line and remote blower options.
• Welded seams, hemmed edges and hand-finished craftsmanship.
• Recessed easy-access controls.
• Infinite-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with two settings.
• Removable, dishwasher-safe stainless steel baffle filters.
• Transition with backdraft damper.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
• 6" (152) , 12" (305) , 18" (457) , 24" (610) high stainless steel duct covers.
Specifications
PRO VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Duct Size
Transition
Island
Stainless Steel
36" (914), 42" (1067), 54" (1372) and 66" (1676)
18" (457)
34" (864)
30" (762) to 36" (914) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two or three 50 W, 120 V par 20 bulbs (included)
Vertical
10" (254) Round
Rectangle to 10" (254) round,
6 1 /
2
" (165) height (included)
38
Blower Options
CFM
PI363418 PI423418
PI543418
PI663418
300*
•
•
•
450*
•
•
•
INTERNAL
500 600
•
900
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
•
•
IN-LINE
600 1100
•
•
•
600
REMOTE
900
•
•
1200
•
•
•
1500
•
•
•
Wolf Pro Ventilation
Pro Island Hood
INSTALLATION
LOCATE ELECTRICAL
THROUGH
TOP OF HOOD
WIDTH MINUS
18" (457)
36"
(914),
42"
(1067)
54" (1372) OR 66" (1676)
HOOD WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
13"
(330)
18" (457)
HOOD HEIGHT
4" (102)
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
34" (864)
HOOD DEPTH
39 wolfappliance.com/specs
NOTE: Do not run electrical wiring through ductwork.
Wolf Pro Ventilation
Pro Hood Liner
12"
(305)
22 1 /
2
"
(572)
WIDTH
Model Options
MODEL
PL342212
PL402212
PL462212
PL522212
PL582212
WIDTH
34
3
/
8
" (873)
40
3
/
8
" (1026)
46 3 /
8
" (1178)
52 3 /
8
" (1330)
58 3 /
8
" (1483)
WEIGHT
44 lbs (20 kg)
50 lbs (23 kg)
55 lbs (25 kg)
60 lbs (27 kg)
65 lbs (29 kg)
FEATURES
• Heavy-duty stainless steel enclosed liner for custom hood applications.
• Internal, in-line and remote blower options.
• Recessed easy-access controls.
• Infinite-speed blower control.
• Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed.
• Halogen lighting with two settings.
• Removable, dishwasher-safe stainless steel baffle filters.
• Transition with backdraft damper.
ACCESSORIES
• Internal, in-line and remote blowers (refer to chart below).
Specifications
PRO VENTILATION
Installation Type
Exterior Finish
Widths
Height
Depth
Installation Height
Electrical Supply
Halogen Bulbs
Discharge
Transition
Wall Hood Liner
Stainless Steel
34 3 /
8
" (873), 40 3 /
8
" (1026)
46 3 /
8
" (1178), 52 3 /
8
" (1330) and 58
3
/
8
" (1483)
12" (305)
22
1
/
2
" (572)
30" (762) to 36" (914) bottom of hood to countertop
120 V AC, 60 Hz, 15 amp dedicated circuit
Two 50 W, 120 V par 20 bulbs
(included)
Vertical
Rectangle to 10" (254) round,
9 3 /
8
" (238) height (included)
40
Blower Options
CFM
PL342212 PL402212
PL462212
PL522212
PL582212
300*
•
•
•
•
450*
•
•
•
•
INTERNAL
500 600
•
•
900
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
•
•
IN-LINE
600 1100
•
•
•
•
600
REMOTE
900
•
•
•
•
1200
•
•
•
•
1500
•
•
•
•
Wolf Pro Ventilation
Pro Hood Liner
INSTALLATION
41 wolfappliance.com/specs
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
(127)
WIDTH MINUS
6"
(152)
34 3 /
8
"
(873),
40 3 /
8
"
(1026)
46
OR
3
/ 8 " (1178), 52
3
/ 8 " (1330)
58 3 /
8
"
(1483) LINER WIDTH
DUCTWORK INSTALLATION
THROUGH ROOF
DECORATIVE HOOD
12"
(305)
LINER HEIGHT
4" (102)
12"
(305)
22
1
/ 2 " (572)
LINER DEPTH
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: A custom decorative hood can be created out of wood, plaster, tile or metal. The shape of the decorative hood is not critical as long as the hood liner fits completely inside the hood.
The decorative hood and liner must fit together at the bottom edge in both width and depth. The height of the hood does not have to match the height of the liner. Interior dimensions of the decorative hood must exceed exterior dimensions of the liner.
Wolf Pro Ventilation
Recirculating Ventilation
Recirculating units are an alternative option for customers required by code to install make-up air systems or where running ventilation ductwork is an issue. They are also an alternative option to ductwork for high rise buildings and apartments. No ductwork is required for the recirculating ventilation unit.
IMPORTANT NOTE: Wolf recirculating ventilation units should not be used with Wolf range or rangetop models with a charbroiler or griddle.
FEATURES
• Heavy-duty stainless steel unit fits above ventilation hood for recirculating applications.
• No ductwork required.
• Charcoal filters.
ACCESSORIES
• Replacement charcoal filters.
Model Options
MODEL
811838
811839
Specifications
RECIRCULATING
Installation Type
Exterior Finish
Widths
Height
Depth
Pro Hoods
WIDTH
30" (762)
36" (914)
WEIGHT
20 lbs (9 kg)
23 lbs (10 kg)
Wall
Stainless Steel
30" (762) and 36" (914)
4" (102)
12" (305)
PW302210, PW362210,
PW302418, PW362418,
PW302718 and PW362718
42
Wolf Pro Ventilation
Recirculating Ventilation
INSTALLATION
43 wolfappliance.com/specs
5"
(127)
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
30"
(762) OR
36"
(914)
HOOD AND RECIRCULATING
UNIT WIDTH
RECIRCULATING UNIT
4"
(102)
10"
(254) OR
18"
(457)
HOOD HEIGHT
12"
(305)
22" (559)
24"
(610) OR
27"
(686)
HOOD DEPTH
30"
(762) TO
36"
(914)
BOTTOM OF
HOOD TO
COUNTERTOP
Wolf Blower Specifications 44
Internal Blower Specifications
450 CFM INTERNAL BLOWER
Specifications
801643
Cooktop Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
CTWH30
8" (203) Round
2.4 amps at 120 V AC, 60 Hz
Required
14 lbs (6 kg)
600 CFM INTERNAL BLOWER
Specifications
801644
Cooktop Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
CTWH36 and IH4227
8" (203) Round
3.0 amps at 120 V AC, 60 Hz
Required
15 lbs (7 kg)
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Low
Calculated for Rigid
10" Galvanized Duct
100 200 300
Airflow Rate (CFM)
400
Airflow rate with cooktop hoods.
High
Med
500
100'
75'
50'
25'
10'
600
NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations.
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
100 200
Low
300
Med
400
Airflow Rate (CFM)
Airflow rate with cooktop hoods.
500
High
600
100'
75'
50'
25'
10'
700
Wolf Blower Specifications
Internal Blower Specifications
900 CFM INTERNAL BLOWER
Specifications
801645
Cooktop Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
CTWH36 and IH4227
8" (203) Round
2.4 amps at 120 V AC, 60 Hz
Required
26 lbs (12 kg)
45 wolfappliance.com/specs
Wolf Blower Specifications
Internal Blower Specifications
500 CFM INTERNAL BLOWER
Specifications
810991
Pro Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
PW302210 and PW362210
8" (203) or 10" (254) Round
(depending on hood)
1.8 amps at 120 V AC, 60 Hz
Required
15 lbs (7 kg)
600 CFM INTERNAL BLOWER
Specifications
810559
Pro Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
PW302418, PW362418,
PW422418, PW302718,
PW362718 and PW422718
8" (203) or 10" (254) Round
(depending on hood)
3.8 amps at 120 V AC, 60 Hz
Required
15 lbs (7 kg)
46
Wolf Blower Specifications 47 wolfappliance.com/specs
Internal Blower Specifications
900 CFM INTERNAL BLOWER
Specifications
811131
Pro Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
PW302418, PW362418,
PW422418, PW302718,
PW362718 and PW422718
10" (254) Round
7.6 amps at 120 V AC, 60 Hz
Required
30 lbs (14 kg)
1200 CFM INTERNAL BLOWER
Specifications
810316
Pro Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
PW482418, PW542418,
PW602418, PW662418,
PW482718, PW542718,
PW602718 and PW662718
10" (254) Round
3.4 amps at 120 V AC, 60 Hz
Required
34 lbs (15 kg)
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
High
Low
100 200 300 400 500
Airflow Rate (CFM)
Airflow rate with pro wall hoods.
Calculated for Rigid
10" Galvanized Duct
600 700
100'
75'
50'
25'
10'
800
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1.1
1.0
0.9
0.8
0.7
Calculated for Rigid
10" Galvanized Duct
High
100 200 300 400 500 600
Airflow Rate (CFM)
700 800
100'
75'
50'
25'
10'
900 1000
Airflow rate with pro wall hoods.
Wolf Blower Specifications 48
Internal Blower Specifications
1200 CFM INTERNAL BLOWER
Specifications
804703
Pro Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
PWC482418 and PWC542418
All pro island hoods
10" (254) Round
4.5 amps at 120 V AC, 60 Hz
Required
27 lbs (12 kg)
1200 CFM INTERNAL BLOWER
Specifications
805087
Pro Hoods
Duct Size
Electrical Rating
Roof or Wall Cap
Shipping Weight
All pro hood liners
10" (254) Round
3.4 amps at 120 V AC, 60 Hz
Required
34 lbs (15 kg)
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
High
Low
100'
75'
50'
100
25'
10'
200 300 400 500 600 700 800
Airflow Rate (CFM)
900 1000 1100 1200 1300
Airflow rate with pro island hoods.
NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations.
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0 100 200 300 400 500
Airflow Rate (CFM)
Airflow rate with pro hood liners.
Calculated for Rigid
10" Galvanized Duct
High
600
100'
75'
50'
25'
10'
700 800
Wolf Blower Specifications
In-line Blower Specifications
600 CFM IN-LINE BLOWER
Specifications
808331
Dimensions (W x H x D)
Cooktop Hoods
Pro Hoods
Duct Size
Transition
Electrical Rating
Roof or Wall Cap
Shipping Weight
24 3 /
8
" (619) x 11 3 /
4
" (298) x 12 1 /
4
" (311)
CTWH30, CTWH36 and IH4227
All pro low-profile wall hoods
PW302418 and PW302718
10" (254) Round
4 1 /
2
" (114) x 18 1 /
2
" (470) to 10" (254) Round
(two transitions included)
2.9 amps at 120 V AC, 60 Hz
Required
44 lbs (20 kg)
24
3
/ 8 "
(619)
11
3
/ 4 "
(298)
18
1
/ 2 "
(470)
4
1
/ 2 "
(114)
21
1
/ 2 "
(546) 12
1
/ 4 "
(311)
600 CFM in-line blower.
49 wolfappliance.com/specs
Wolf Blower Specifications
In-line Blower Specifications
1100 CFM IN-LINE BLOWER
Specifications
808332
Dimensions (W x H x D)
Cooktop Hoods
Downdrafts
Pro Hoods
Duct Size
Transition
Electrical Rating
Roof or Wall Cap
Shipping Weight
24 7 /
8
" (632) x 18" (457) x 18" (457)
CTWH30, CTWH36 and IH4227
DD30R, DD36R and DD45R
All pro 24" deep wall hoods
All pro 27" deep wall hoods
All pro wall chimney hoods
All pro island hoods
All pro hood liners
10" (254) Round
8 1 /
2
" (216) x 12" (305) to 10" (254) Round
(two transitions included)
5.0 amps at 120 V AC, 60 Hz
Required
63 lbs (29 kg)
24 7/8 "
(632)
18"
(457)
12"
(305)
22"
(559)
8"
(203)
18"
(457)
1100 CFM in-line blower.
50
Wolf Blower Specifications 51 wolfappliance.com/specs
Remote Blower Specifications
600 CFM REMOTE BLOWER
Specifications
801640
Dimensions (W x H x D)
Cooktop Hoods
Pro Hoods
Duct Size
Electrical Rating
Shipping Weight
21 3 /
4
" (527) x 24 1 /
2
" (622) x 4 3 /
4
" (121)
CTWH30, CTWH36 and IH4227
All pro low-profile wall hoods
PW302418 and PW302718
10" (254) Round
2.4 amps at 120 V AC, 60 Hz
32 lbs (15 kg)
28 1/4 "
(718)
15 1/2 "
(394)
10" (254)
DIAMETER
20 3/4 "
(527)
24 1/2 "
(622)
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Low
Calculated for Rigid
10" Galvanized Duct
Med
High
100 200 300 400
Airflow Rate (CFM)
Airflow rate with cooktop hoods.
500
100'
75'
50'
25'
Hood Only
600 700
NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations.
14"
(356)
24 3/4 "
(629)
900 CFM remote blower.
4 3/4 "
(121)
Wolf Blower Specifications 52
Remote Blower Specifications
900 CFM REMOTE BLOWER
Specifications
801641
Dimensions (W x H x D)
Cooktop Hoods
Downdrafts
Pro Hoods
Duct Size
Electrical Rating
Shipping Weight
21 3 /
4
" (527) x 24 1 /
2
" (622) x 4 3 /
4
" (121)
CTWH30, CTWH36 and IH4227
DD30R, DD36R and DD45R
All pro low-profile wall hoods
PW302418, PW362418, PW422418
PW482418 and PW542418
PW302718, PW362718, PW422718
PW482718 and PW542718
All pro wall chimney hoods
PI363418, PI423418 and PI543418
All pro hood liners
10" (254) Round
5.7 amps at 120 V AC, 60 Hz
32 lbs (15 kg)
28 1/4 "
(718)
15 1/2 "
(394)
10" (254)
DIAMETER
20 3/4 "
(527)
24 1/2 "
(622)
14"
(356)
24 3/4 "
(629)
900 CFM remote blower.
4 3/4 "
(121)
100' 50' Downdraft Only
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Low
Med
Calculated for Rigid
10" Galvanized Duct
High
100 200 300 400 500 600
Airflow Rate (CFM)
700 800 900 1000
Airflow rate with 30" (762) downdraft.
100' 50' Downdraft Only
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Low
100 200 300 400 500 600
Airflow Rate (CFM)
Airflow rate with 36" (914) downdraft.
Calculated for Rigid
10" Galvanized Duct
Med
700
High
800 900 1000
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1.4
1.3
1.2
1.1
1.0
0.9
0.8
Calculated for Rigid
10" Galvanized Duct
Low
100'
75'
50'
25'
Hood Only
Med
High
100 200 300 400 500 600
Airflow Rate (CFM)
700 800 900 1000
Airflow rate with 30" (762) to 42" (1067) pro wall hoods.
Wolf Blower Specifications 53 wolfappliance.com/specs
Remote Blower Specifications
900 CFM REMOTE BLOWER
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1.1
1.0
0.9
0.8
0.7
Calculated for Rigid
10" Galvanized Duct
100 200 300
Low
400 500 600
Airflow Rate (CFM)
700
Med
800
High
100'
75'
50'
25'
Hood Only
900 1000
Airflow rate with 48" (1219) to 66" (1676) pro wall hoods.
NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations.
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
Low
100 200 300 400 500 600
Airflow Rate (CFM)
Airflow rate with pro island hoods.
Med
100'
75'
50'
25'
Hood Only
High
700 800 900 1000
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
Low
100'
75'
50'
25'
Hood Only
Med
High
100 200 300 400 500 600
Airflow Rate (CFM)
700 800 900 1000
Airflow rate with pro hood liners.
Wolf Blower Specifications 54
Remote Blower Specifications
1200 CFM REMOTE BLOWER
Specifications
801642
Dimensions (W x H x D)
Cooktop Hoods
Downdrafts
Pro Hoods
Duct Size
Electrical Rating
Shipping Weight
18" (457) x 29 1 /
2
" (749) x 10" (254)
CTWH30, CTWH36 and IH4227
DD30R, DD36R and DD45R
All pro 24" deep wall hoods
All pro 27" deep wall hoods
All pro wall chimney hoods
All pro island hoods
All pro hood liners
10" (254) Round
3.0 amps at 120 V AC, 60 Hz
38 lbs (17 kg)
29 1/2 "
(749)
14 3/4 "
(375)
10"
(254)
DIAMETER
18" (457)
10"
(254)
29 1/2 "
(749)
10 1/8 "
(257)
22"
(559)
1200 CFM remote blower.
7 1/4 "
(184)
100' 50' Hood Only
1.1
1.0
0.9
0.8
1.5
1.4
1.3
1.2
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Med
High
Calculated for Rigid
10" Galvanized Duct
Low
100 200 300 400 500 600 700 800
Airflow Rate (CFM)
900 1000 1100 1200 1300
Airflow rate with 30" (762) downdraft.
( )
100' 50' Hood Only
1.1
1.0
0.9
0.8
0.7
1.5
1.4
1.3
1.2
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Low
Med
High
Calculated for Rigid
10" Galvanized Duct
100 200 300 400 500 600 700 800
Airflow Rate (CFM)
900 1000 1100 1200 1300
Airflow rate with 36" (914) downdraft.
A
0.7
0.6
0.5
0.4
0.3
1.2
1.1
1.0
0.9
0.8
0.2
0.1
0
0 200
Low
400
100' 75' 50' 25' Hood Only
Calculated for Rigid
10" Galvanized Duct
Med
High
600 800
Airflow Rate (CFM)
1000 1200
Airflow rate with 30" (762) to 42" (1067) pro wall hoods.
1400
Wolf Blower Specifications 55 wolfappliance.com/specs
Remote Blower Specifications
1200 CFM REMOTE BLOWER
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
Low
200
Med
400 600 800
Airflow Rate (CFM)
100'
75'
50'
25'
Hood Only
High
1000 1200
Airflow rate with 48" (1219) to 66" (1676) pro wall hoods.
1400
NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations.
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
Low
Med
100'
75'
50'
25'
Hood Only
High
100 200 300 400 500 600 700 800
Airflow Rate (CFM)
900 1000 1100 1200 1300
Airflow rate with pro island hoods.
100' 75' 50' 25' Hood Only
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1.3
1.2
1.1
1.0
0.9
High
Calculated for Rigid
10" Galvanized Duct
Med
Low
100 200 300 400 500 600 700 800
Airflow Rate (CFM)
900 1000 1100 1200 1300
Airflow rate with pro hood liners.
Wolf Blower Specifications 56
Remote Blower Specifications
1500 CFM REMOTE BLOWER
Specifications
804701
Dimensions (W x H x D)
Cooktop Hoods
Downdrafts
Pro Hoods
Duct Size
Electrical Rating
Shipping Weight
21" (533) x 29 1 /
2
" (749) x 10" (254)
CTWH30, CTWH36 and IH4227
DD30R, DD36R and DD45R
All pro 24" deep wall hoods
All pro 27" deep wall hoods
All pro wall chimney hoods
All pro island hoods
All pro hood liners
10" (254) Round
4.3 amps at 120 V AC, 60 Hz
45 lbs (20 kg)
29 1/2 "
(749)
14 3/4 "
(375)
10" (254)
DIAMETER
21"
(533)
10"
(254)
29 1/2 "
(749)
10 3/8 "
(264)
25"
(635)
1500 CFM remote blower.
7 1/4 "
(184)
100' 75' 50' 25' Hood Only
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1.4
1.3
1.2
1.1
1.0
0.9
0.8
Calculated for Rigid
10" Galvanized Duct
200 400
Low
Med
600 800 1000
Airflow Rate (CFM)
High
1200 1400
Airflow rate with cooktop hoods.
1600
100' 50' Hood Only
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Low
Med
High
200 400 600 800 1000
Airflow Rate (CFM)
Airflow rate with 36" (914) downdraft.
Calculated for Rigid
10" Galvanized Duct
1200 1400 1600
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
100' 75' 50' 25' Hood Only
Calculated for Rigid
10" Galvanized Duct
Low
Med
High
200 400 600 800 1000
Airflow Rate (CFM)
1200 1400
Airflow rate with 30" (762) to 42" (1067) pro wall hoods.
1600
Wolf Blower Specifications 57 wolfappliance.com/specs
Remote Blower Specifications
1500 CFM REMOTE BLOWER
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
200 400
Low
Med
600 800 1000
Airflow Rate (CFM)
100'
75'
50'
25'
1200
Hood Only
High
1400
Airflow rate with 48" (1219) to 66" (1676) pro wall hoods.
1600
NOTE: Airflow rates for blowers are approximate. A qualified HVAC professional should make actual system calculations.
100' 75' 50' 25' Hood Only
1.0
0.9
0.8
0.7
0.6
1.4
1.3
1.2
1.1
0.5
0.4
0.3
0.2
0.1
0
0
Calculated for Rigid
10" Galvanized Duct
Low
Med
200 400 600 800 1000
Airflow Rate (CFM)
Airflow rate with pro island hoods.
High
1200 1400 1600
100' 75' 50' 25' Hood Only
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
Low
Med
High
200 400 600 800 1000
Airflow Rate (CFM)
Airflow rate with pro hood liners.
Calculated for Rigid
10" Galvanized Duct
1200 1400 1600
Wolf Blower Specifications 58
In-Line Blower Installation
600 CFM IN-LINE BLOWER
Ductwork options are provided in the illustrations below for installation of the 600 CFM in-line blower with horizontal or vertical discharge. Refer to installation instructions shipped with the in-line blower for detailed specifications.
4 1 /
2
"
(114) x
18 1 /
2
"
(470)
TO
10"
(254)
ROUND TRANSITION
10"
(254)
ROUND
DUCT
ROOF CAP
WALL CAP
10" (254)
ROUND DUCT
Horizontal discharge.
ELBOW
4 1 / 2 " (114) x 18 1 / 2 " (470)
TO 10" (254)
ROUND TRANSITION
10" (254)
ROUND
DUCT
ROOF CAP
10" (254)
ROUND DUCT
Vertical discharge.
Choose the mounting option for the 600 CFM in-line blower that best suits your installation.
A) Mounting brackets in factory-shipped position.
Discharge parallel to joists.
B) Mounting brackets flipped over and mounted to discharge sides of housing. Discharge parallel to joists.
C) Mounting brackets mounted to discharge sides of housing. Discharge perpendicular to joists.
D) Mounting brackets flipped over to give approximately
1" (25) more clearance. Discharge parallel to joists.
E) Mounting brackets mounted to top of sides of housing.
Discharge parallel to joists.
F) Mounting brackets flipped over and mounted to top of sides of housing. Discharge parallel to joists.
A
1 1 /
8
"
(29)
MAX
21
1
/ 2 " (546)
1
1
/ 2 " (38) TO 2
1
/ 2 "
(64)
1
1
/ 2 " (38) TO 2
1
/ 2 "
(64)
D
21 1 / 2 " (546)
9
1
/ 2 " (241) TO 10
1
/ 2 " (267)
B
21 1 / 2 " (546)
E
21 1 /
2
"
(546)
10 3 /
4
"
(273) TO
11 3 /
4
"
(298)
C
12 1 /
4
"
(311)
Mounting options.
F
21
1
/ 2 " (546)
Wolf Blower Specifications 59 wolfappliance.com/specs
In-Line Blower Installation
1100 CFM IN-LINE BLOWER
Ductwork options are provided in the illustrations below for installation of the 1100 CFM in-line blower with horizontal or vertical discharge. Refer to installation instructions shipped with the in-line blower for detailed specifications.
8"
(203) x
12"
(305)
TO
10"
(254)
ROUND TRANSITIONS
10"
(254)
ROUND
DUCT
ROOF CAP
WALL CAP
10"
(254)
ROUND DUCT
Horizontal discharge.
ELBOW
Choose the mounting option for the 1100 CFM in-line blower that best suits your installation.
A) Mounting brackets in factory-shipped position, mounted directly to joists. Discharge parallel to joists.
B) Mounting brackets flipped over and mounted to additional framing. Discharge perpendicular to joists.
C) Mounting brackets flipped over and mounted to additional framing. Discharge vertical.
D) Mounting brackets flipped over and mounted to top of housing. Housing secured with cables. Discharge parallel to joists.
A
STRAIGHT-
THROUGH
DISCHARGE
22"
(559)
1 1 /
8
"
(29)
MAX
C
STRAIGHT-
THROUGH
DISCHARGE
1 1 /
2
"
(38)
TO
2 1 / 2 "
(64)
18"
(457)
8" (203) x 12" (305)
TO
10"
(254)
ROUND TRANSITIONS
10"
(254)
ROUND
DUCT
ROOF CAP
10" (254)
ROUND DUCT
Vertical discharge.
RIGHT-ANGLE
DISCHARGE
1 1 /
2
"
(38)
TO
2 1 / 2 "
(64)
18"
(457)
B
Mounting options.
D
STRAIGHT-
THROUGH
DISCHARGE
22" (559)
Wolf Blower Specifications
Remote Blower Installation
600 AND 900 CFM REMOTE BLOWERS
Cut-out dimensions are provided in the illustrations for installation of the 600 CFM or 900 CFM remote blower on the roof or an exterior wall. Refer to installation instructions shipped with the remote blower for detailed specifications.
If the remote blower is to be installed on a flat roof, a curb will have to be constructed for a proper fit. Follow dimensions shown in the illustration below.
29 1/2 "
(749)
2"
(51)
10 3 /
8
"
(264)
8 1 /
2
"
(216)
REMOVE
SHINGLES
20 3 / 4 " (527)
11"
(279)
DIAMETER
PILOT
HOLE
20 1 /
2
"
(521)
1
1
/ 4 " (32)
DIAMETER
9 1 /
8
"
(232)
7 1 /
4
"
(184)
EXTERIOR ROOF VIEW
Roof installation.
7"
(178)
25"
(635)
Curb for flat roof.
2"
(51)
12 7 /
8
"
(327)
1
10 3 / 4 "
(273)
24
3
/ 4 " (629)
8
1
/ 2 "
(216)
REMOVE
SIDING 11"
(279)
DIAMETER
PILOT
HOLE
1
/ 4 " (32)
DIAMETER
9 1 /
8
"
(232)
28 1 /
4
"
(718)
7 1 / 4 "
(184)
EXTERIOR WALL VIEW
Exterior wall installation.
60
Wolf Blower Specifications 61 wolfappliance.com/specs
Remote Blower Installation
1200 CFM REMOTE BLOWER
Cut-out dimensions are provided in the illustrations for installation of the 1200 CFM remote blower on the roof or an exterior wall. Refer to installation instructions shipped with the remote blower for detailed specifications.
If the remote blower is to be installed on a flat roof, a curb will have to be constructed for a proper fit. Follow dimensions shown in the illustration below.
29 1/2 "
(749)
22"
(559)
Curb for flat roof.
2"
(51)
2"
(51)
7"
(178)
15" (381)
12 11 /
16
"
(322)
1 1 /
4
"
(32) DIAMETER
REMOVE SHINGLES
1"
(25)
20 1 / 2 "
(521)
PILOT HOLE
(CENTERED
BETWEEN
RAFTERS)
11" (279)
DIAMETER
9 13 / 16 "
(249)
18" (457)
EXTERIOR ROOF VIEW
Roof installation.
17"
(431)
14 11 / 16 "
(373)
PILOT HOLE
(CENTERED
BETWEEN
STUDS)
1
1
/ 4 " (32)
DIAMETER
3"
(76)
29 1 /
2
"
(749)
11" (279)
DIAMETER
REMOVE
SIDING
11 13 /
16
"
(300)
22"
(559)
EXTERIOR WALL VIEW
Exterior wall installation.
Wolf Blower Specifications
Remote Blower Installation
1500 CFM REMOTE BLOWER
Cut-out dimensions are provided in the illustrations for installation of the 1500 CFM remote blower on the roof or an exterior wall. Refer to installation instructions shipped with the remote blower for detailed specifications.
If the remote blower is to be installed on a flat roof, a curb will have to be constructed for a proper fit. Follow dimensions shown in the illustration below.
29 1/2 "
(749)
22"
(559)
Curb for flat roof.
2"
(51)
2"
(51)
7"
(178)
18" (457)
12
11
/ 16 "
(322)
1 1 /
4
"
(32) DIAMETER
REMOVE SHINGLES
1"
(25)
20
1
/ 2 "
(521)
PILOT HOLE
(CENTERED
BETWEEN
RAFTERS)
11" (279)
DIAMETER
12
5
/ 8 "
(321)
21" (533)
EXTERIOR ROOF VIEW
Roof installation.
20"
(508)
14
11
/ 16 "
(373)
PILOT HOLE
(CENTERED
BETWEEN
STUDS)
1 1 / 4 " (32)
DIAMETER
3"
(76)
29
1
/ 2 "
(749)
11"
(279)
DIAMETER
REMOVE
SIDING
14
5
/ 8 "
(371)
25" (635)
EXTERIOR WALL VIEW
Exterior wall installation.
62
Wolf Ventilation FAQ 63 wolfappliance.com/specs
Frequently Asked Questions
HOW TO DETERMINE WHICH TYPE OF BLOWER TO USE?
Many factors can influence the decision between using an internal, in-line or remote blower. The CFM (based on the cooking appliance output), length of the duct run and space available to mount the blower are primary considerations.
Internal blowers are mounted inside the hood or downdraft. In-line blowers are mounted between the hood and the exterior of the home. Remote blowers can be mounted on the roof or, in some cases, on an exterior wall.
HOW CAN BLOWER NOISE BE MINIMIZED?
Some blower noise is considered normal while the blower is operating. If noise is a concern, a remote blower is recommended. Using a remote blower will minimize the amount of blower noise but will not eliminate the noise completely. Where the remote blower is installed on the home will also affect the amount of noise. To reduce noise further for remote blower applications, an attenuator may be necessary. An attenuator is an electronic device that is effectively the opposite of an amplifier. While an amplifier provides gain, an attenuator provides loss in sound level.
WHAT TYPE OF DUCTING IS RECOMMENDED?
Wolf hoods and downdrafts should be vented using smooth, rigid metal ducting. The ridges found in flexible metal ducting create turbulence and will diminish airflow.
The larger the ducting, the less noise there will be and the better the rate of airflow.
HOW CAN THE DUCT RUN BE MOST EFFICIENT?
For maximum performance keep the duct run straight and short, with a limited number of elbows and transitions.
45° elbows are more efficient than 90° elbows. Be sure to use an external roof or wall cap. Wolf ventilation products will operate most efficiently when ductwork does not exceed 50' (15 m) in length.
WHAT IS MAKE-UP AIR?
When a ventilation hood or downdraft is operating, it draws air from inside the house to the outside, creating a slight vacuum within the house. This creates negative pressure (pressure inside the house is less than the pressure outside). If the negative pressure is strong enough, it can cause the furnace and other fuel-burning appliances to backdraft dangerous gases such as carbon monoxide into the home. All exhaust fans need an adequate supply of fresh air from the outside to operate safely. The air needed for this purpose is called “make-up air.” Check with a local HVAC professional to determine if your heating or air conditioning system makes allowances for additional make-up air. Make-up air can be introduced by simply opening a window or door.
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved.
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.
Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc.
(collectively, the “Company Marks.”) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.
Wolf Appliance Products Limited Warranty
FOR RESIDENTIAL USE ONLY
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, your Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.
LIMITED FIVE YEAR WARRANTY
For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of
Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE,
INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION
OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER
EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf
Appliance, Inc., P. O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com or call 800-222-7820.
*Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day parts and labor warranty for cosmetic defects.
*Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.
Wolf Appliance Outdoor Products Limited Warranty
PRODUCT MUST BE APPROVED FOR OUTDOOR USE, DESIGNATED BY MODEL AND SERIAL NUMBER
FOR RESIDENTIAL USE ONLY
FULL ONE YEAR WARRANTY*
For one year from the date of original installation, your Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.
LIMITED FIVE YEAR WARRANTY
Wolf Appliance warrants the stainless steel briquette trays, gas valves, drip pans, electronic control boards and electric heating elements to be free from defects in materials and workmanship under normal residential use for a period of five years from the date of original installation. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf
Appliance, Inc. Service will be provided during normal business hours.
LIMITED LIFETIME WARRANTY
For the life of the product, Wolf Appliance will repair or replace any stainless steel part including all fabricated stainless steel components, stainless steel burners and grates (excluding what is covered in the Limited Five
Year Warranty) to be defective from workmanship and when subjected to normal domestic use and service. This warranty excludes surface corrosion, scratches, discoloration, weather and atmospheric related staining, and minor surface rust and oxidation which are normal conditions. Labor to remove and replace defective parts is not covered. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of
Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE,
INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION
OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER
EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf
Appliance, Inc., P. O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com or call 800-222-7820.
*Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day parts and labor warranty for cosmetic defects.
WOLF APPLIANCE, INC.
P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM
800.222.7820
WVG 12 / 2011
Advertisement