INSTALLATION AND PROGRAMMING GUIDE
FRI 2 : 52 PM
1 2 3 4
J K
L
5 6 7 8
9
Y Z
V W
X
0 CMD
K
BAC ENT
ER
TABLE OF CONTENTS
About the Keypad .........................1
Keypad Features ........................... 2
Enter Characters ........................... 4
Number Pad .......................................................... 4
Panic Key Options .............................................. 5
User Options Menu ............................................. 6
Test the Keypad ...........................28
End User Training ....................... 30
Keypad Arming and Disarming .....................31
Keypad Access Control ................................... 33
Keypad Entry Delay ..........................................34
Install the Keypad ......................... 7
Remove the Cover .............................................. 7
Wire the Keypad.................................................. 8
Wire for Access Control ................................... 11
Wire the Electronic Lock ................................13
Wire the 333 Suppressor .................................13
Program the Keypad ...................16
Keypad Options ...................................................16
Custom Card Format .................. 20
Additional Programming ................................. 27
Wiring Specifications..................35
Keypad Specifications ............... 36
Public Card Formats ...................37
Readers and Credentials ............38
Compliance Specifications ....... 40
Accessories .................................. 40
Certifications ................................41
FCC Information ......................... 42
Industry Canada Information .... 43
ABOUT THE KEYPAD
Thinline Series (7060, 7063, 7070, 7073, 7160, 7163, 7170, and 7173) and Aqualite Series
(7060A, 7063A, 7070A, and 7073A) LCD keypads offer flexible features and functionality.
Each keypad provides:
• Custom 16-character home or business name in the display
• Four 2-button panic keys
• AC Power/Armed LED
• 32-character display
• Backlit keyboard and DMP logo
• Internal speaker
• Red keyboard lighting in alarm conditions
• Simple harness connection to 4-wire keypad bus
• Optional backboxes for conduit or wall mount applications
Models 7070/A, 7073/A, 7170, and 7173
Provide four fully-programmable, Class B, Style A, supervised, power limited protection zones that can be programmed for a variety of burglary and access control applications.
Models 7063/A, 7073/A, 7163, and 7173
Provide a built-in proximity card reader designed to read proximity credentials.
Models 7073/A and 7173
Provide a door strike relay and allow Wiegand input from external card readers.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
1
KEYPAD FEATURES
1
Select Keys
2 3 4
2
Armed/Power
LEDs
Proximity
Credential Reader and Backlit Logo
FRI 2 : 52 PM
Keypad Display/
Status List
Panic Keys
1 2 3 4
J K
L
5 6 7 8
V W
X
9
Y Z
0 CMD
K
BAC ENT
ER
Figure 1: 7000 Series LCD Keypad
Command
(CMD) Key
Back Arrow Key
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
32-Character Display
Power LED
Armed LED
Proximity
Credential
Reader and
Backlit Logo
ABC SECURITY
FRI 2 : 52 PM
Select Keys
1
5
9
Y Z
2
6
3
7
4
8
0 CMD
K
BAC ENT
ER
Figure 2: Thinline 7100 Series LCD Keypad
Command
Back Arrow
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
3
4
ENTER CHARACTERS
NUMBER PAD
7
8
5
6
9
0
1. Choose a character from the table. Use the Greek Characters table if Greek was selected as the keypad language setting.
2. Identify the Number the character correlates with and press that number on the number pad.
3. Identify the Select Key for the character and press that select key on the keypad.
Press that select key again for the lowercase letter (Latin characters only).
4. When the desired character displays on the keypad, return to step 1 to enter another character or press CMD if finished.
SELECT KEY SELECT KEY
NUMBER NUMBER
1 2 3 4 1 2 3 4
A B C ( [ { Α Β Γ ( [ {
3
4
1
2 D
G
J
E
H
K
F
I
L
) ] }
! ^ ~
? “ |
3
4
1
2 Δ
Η
Κ
Ε
Θ
Λ
Ζ
Ι
Μ
) ] }
! ^ ~
? “ |
S
V
M
P
T
W
N
Q
U
X
O
R
Y
- +
Z
. ‘
Space :
* <
Table 1: Latin Characters
/ \ `
& $
@ %
, =
_ ;
# >
7
8
5
6
9
0
Τ
Χ
Ν
Π
Υ
Ψ
Ξ
Ρ
Φ
Ω
Ο
Σ
Space
- +
Space
. ‘
Space :
* <
Table 2: Greek Characters
/ \ `
& $
@ %
, =
_ ;
# >
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
PANIC KEY OPTIONS
2-Button Panic Keys
All keypads offer a panic key function that allows users to send panic, emergency, or fire reports to the central station in an emergency. Enable the panic key function in the keypad user menu. Place the supplied icon stickers below the top row select keys. The user must press and hold the two select keys for two seconds until a beep is heard.
Panic (left two select keys)—Zone 19 + Device Address
Emergency Non-Medical (center two select keys)—Zone 29 + Device Address
Fire (right two select keys)—Zone 39 + Device Address
7/0 Panic Keys
All keypads allow the user to initiate a panic alarm by pressing the 7 and 0 (zero) keys at the same time for one-half (1/2) second. Enable the 7/0 Panic function in Installer Options.
When enabled, all keypads send a Zone Short message to the panel for the first zone of the keypad address. When the keys are released, a Zone Restore message can be sent from the initiating keypad. To produce a panic alarm, program the first zone of the keypad address as a panic type (PN) in panel programming. Place a 1k Ohm end-of-line (EOL) resistor, DMP Model 311, across the white/brown pair of zone wires on models 7070/A,
7073/A, 7170, and 7173. A Zone Restore message sends when the keys are released. The 1k
Ohm EOL resistor is not required on 7060/A, 7063/A, 7160, and 7163 keypads.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
5
USER OPTIONS MENU
To access the Options menu, press and hold the back arrow and CMD keys for 2 seconds.
Backlighting Brightness
Adjust the LCD display brightness level, power and armed LEDs, the green keyboard, and the logo backlighting. At SET BRIGHTNESS , use the left select key to decrease the brightness and the right select key to increase the brightness. If the brightness level is lowered, it reverts to maximum intensity whenever a key is pressed. If no keys are pressed, and the speaker has not sounded for 30 seconds, the user-selected brightness level restores.
Internal Speaker Tone
Adjust the keypad internal speaker tone. At SET TONE , use the left select key to decrease the tone and the right select key to increase the tone.
Internal Volume Level
Adjust the keypad internal speaker volume for key presses and entry delay tone conditions. During alarm and trouble conditions, the volume is always at maximum level.
At SET VOLUME LEVEL , use the left select key to decrease the volume and the right select key to increase the volume.
Model Number
Display the keypad model number, firmware version, and date.
Keypad Address
Display the current keypad address.
6 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
INSTALL THE KEYPAD
1
REMOVE THE COVER
The keypad housing is made up of two parts: the cover, which contains the circuit board and components, and the base.
To separate the keypad cover from the base, insert a flathead screwdriver into one of the slots on the bottom of the keypad and gently lift the screwdriver upward.
Repeat with the other slot. Gently separate the cover from the base and set the cover containing the keypad components aside. See Figure 3.
Cover
Base
Figure 3: Separate the
Keypad Housing
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
7
8
2
WIRE THE KEYPAD
Each keypad model has specific wiring assignments. All zones are supervised. Use
1k Ohm EOL resistors, DMP Model 311 on keypad zones 1-4. Locate the keypad model below and refer to Figure 5 to wire the keypad.
Models 7060/A, 7063/A, 7160, and 7163
Supplied with a 4-wire harness for panel keypad bus connection.
Models 7070/A, 7073/A, 7170, and 7173
Supplied with a 12-wire data bus/zone harness. Four wires connect to the keypad bus.
The remaining eight wires are for the four zone inputs, four wires for each zone.
Models 7073/A and 7173
Supplied with a 5-wire output/reader harness and a 12-wire data bus/zone harness.
J5
Firmly grasp the wires near the base and hold the outside edges of the keypad housing. Line up the red and yellow wires with the guides on the board to inset the connector into the J5 keypad terminal. Observe wire colors when connecting the red, yellow, green, and black wires to the keypad bus. See Figure 4.
R
• Connect red wire to panel terminal 7
• Connect yellow wire to panel terminal 8
• Connect green wire to panel terminal 9
• Connect black wire to panel terminal 10 Figure 4: Wiring Harness
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
Additional Power Supply
If the current draw for all keypads exceeds the panel output, provide additional current by adding a Model 505-12 auxiliary power supply.
1. Connect all keypad black ground wires to the power supply negative terminal.
2. Run a jumper wire from the power supply negative terminal to the panel common ground terminal.
3. Connect all keypad power (+12 VDC) wires to the power supply positive terminal.
Do not connect the power supply positive terminal to any panel terminal. Refer to the 505-12 Power Supply Installation Guide if needed (LT-0453).
Keypad Bus Monitor
For listed fire protective systems, the 893A Module or 277 Trouble Sounder must be installed on the XR150/XR550 Series panel to monitor the keypad bus. It should be programmed to sound when the keypad bus fails to operate.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
9
10
Surface and Backbox
Mounting Holes
Combined 4-square and 3-gang switch box
Mounting Holes
Green/White
– Connect Reader Data 0
White – Connect Reader Data 1
Orange – Door Strike N/O
Gray –
Violet
Door Strike C
–
Door Strike N/C
ExternalReader/Door Strike
7073/7073A, 7173 Keypads
1K EOL
Yellow/White
White/Yellow
– Zone 4
1K EOL
Orange White
White/Orange
– Zone 3
1K EOL
Red/White
White/Red
1K EOL
Brown/White
White/Brown
– Zone 2
– Zone 1
Black
– Ground
Green – Receive Data
Yellow – Send Data
Red – Keypad Power
All Keypads
Zones 1-4
7070/7070A, 7073/7073A, 7170/7173 Keypads
*All zones are supervised and suitable for fire applications.
*Maximum zone line impedence is 100 Ohms.
*Ground fault detected at 1420 Ohms or less.
Surface and Backbox
Mounting Holes
Figure 5: Keypad Back Showing Wiring
Harness Assignments
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
3
WIRE FOR ACCESS CONTROL
Internal Access Control Reader
The 7063/A, 7073/A, 7163, and 7173 keypads provide a built-in proximity card reader that is compatible with most standard 125 kHz proximity credentials. An external
13.56 MHz proximity reader can be connected and will be compatible with 13.56 MHz proximity credentials. For a list of publicly supported card formats, see Public Card
Formats.
Note : Some proximity credentials are not compatible with DMP proximity keypads. Test the intended proximity credentials with the application before installation. DMP does not guarantee compatibility with credentials not purchased from DMP.
External Access Control Reader
To accept Wiegand data input from other external card readers, connect a 12 VDC external reader to a 7073/A or 7173 keypad. Connect the red and black power wires from the reader to the power wires from the panel. These connect in parallel with the keypad power wires. Connect the reader (Data 1) wire to the white wire on the 5–wire keypad cable. Connect the reader (Data 0) wire to the green/white wire on the 5–wire keypad cable. See Figure 6.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
11
12
NC
C
NO
WHT
GRN
Z4 -
Z4 +
Z3 -
Z3 +
Z2 -
Z2 +
Z1 -
Z1 +
BLK
GRN
YEL
RED
Green/White* - Connect Reader Data 0
White - Connect Reader Data 1
Orange - Door Strike Normally Open
Gray - Door Strike Common
Violet - Door Strike Normally Closed s s s s s s s s
1K EOL – Yellow & White
Zone 4
1K EOL
1K EOL
– Orange & White
Zone 3 (REX)
– Red & White
Zone 2
1K EOL – Brown & White
Zone 1 (7/0 Panic)
Black – Ground
Green – Receive Data
Yellow – Send Data
Red – Keypad Power
External Card
Reader
To Panel Keypad Bus
*Only the green/white, white, black, and red wires connect to the external card reader.
Figure 6: Access Control Wiring
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
4
WIRE THE ELECTRONIC LOCK
The 7073/A and 7173 keypads provide one internal programmable Form C single pole, double throw (SPDT) relay for controlling door strikes or magnetic locks. Three wires on the 5-wire harness, violet normally closed (N/C), gray common (COM), and orange normally open (N/O), allow you to connect devices to the relay. The Form C relay draws up to 15 mA of current and the contacts are rated for 1 Amp at 30 VDC maximum.
5
WIRE THE 333 SUPPRESSOR
One Model 333 Suppressor is included with the 7073/A and 7173 keypads. If the device being controlled by the relay is connected to the N/O and C wires, install the suppressor on the N/O and C wires. If the device is connected to the N/C and C wires, install the 333 on N/C and C wires. See Figure 7.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
13
14
Keypad
5-Wire Harness
Green/White – D0
White – D1
Orange – N/O
Gray – C
Violet – N/C
N/O
C
N/C
– +
Magnetic Door Lock
Model 333
Supressor
DMP 505
Power Supply
Figure 7: 5-Wire Harness and 333 Suppressor Installation
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
Door Strike Relay Operation
When the user code sent from the reader is verified by the panel, the keypad door strike relay activates for five seconds. During this time, the access door connected to
Zone 2 must be opened to start the programmed entry/exit timer and Zone Bypass if programmed and used. The five second door strike is panel programmable when the keypad is used on an XR150/XR550 Series panel.
Zone 2 Door Contact with Bypass
If the door being released by the 7073/A and 7173 keypad is protected, you can provide a programmed bypass time by connecting its contact to Zone 2 (white/red pair) on the keypad and enabling the bypass feature. Door contacts may be N/C or N/O.
Zone 3 Request to Exit
You can also connect a N/O PIR (or other motion sensing device) or a mechanical switch to Zone 3 (white/orange pair) on the 7073/A and 7173 keypad to provide Request to Exit
(REX) capability. When Zone 3 shorts, the keypad relay activates for 5 seconds. During this time, the user can open the protected door to start the programmed Bypass entry/ exit timer. If the door is not opened within five seconds, the relay restores to its locked state. A Zone 3 REX is inhibited for three seconds after the keypad reads a card and a door strike occurs. This is to allow area entry and pass under a REX PIR.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
15
PROGRAM THE KEYPAD
Keypad Options and Keypad Diagnostic menus allow install and service technicians to configure and test keypad operation. To access the installer options:
1. Hold down the back arrow and CMD keys for two seconds.
2. At SET BRIGHTNESS , enter 3577 (INST) and press CMD .
The display changes to KPD OPT KPD DIAG and STOP . The Keypad Options menu allows you to set the keypad address, select Supervised or Unsupervised mode, change the default keypad message, selectively enable the 2-button Panic keys, Bypass, REX, and set entry card options.
All programming options display on all keypads. However, actual operation for some programming options is restricted to the appropriate model.
KEYPAD OPTIONS
KPD KPD
OPT DIAG STOP
Keypad Options
To program keypad options, press KPD OPT .
CURRENT KEYPAD
ADDRESS: 1
Current Keypad Address
Set the current keypad address from 01 to 08 for
XT30/XT50/XR150 Series panels or 01 to 16 for XR550 Series panels. The default address is 01. To change the current address, press any select key and enter the new address. Do not enter a leading zero for addresses 01 to 09.
16 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
KEYPAD MODE:
*SUP
ARM PANIC KEYS:
*PN EM *FI
UNSUP
DEFAULT KPD MSG:
Keypad Mode
Keypads with programmed zones must be supervised and cannot share an address with other keypads. Unsupervised keypads can operate together sharing the same address, but cannot be used when Device Fail Output has a programmed value other than zero. To select a keypad mode, press the select key under SUP or UNSUP . An asterisk appears next to the selected option.
Default Keypad Message
Enter a custom message of up to 16 characters to appear at the top of the keypad display. Press any select key, enter a new message, and press CMD .
Arm Panic Keys
Use this option to configure the select keys as two-button panic keys. To enable or disable a panic option, press the select key under the desired name: PN (panic), EM
(emergency), and FI (fire). Press the select key again to disable the panic option. Once the panic option is enabled, an asterisk displays next to the selected option(s).
7/0 PANIC
ENABLE: NO
7/0 Panic
Press the fourth select key to choose YES , configuring the
7 and 0 keys as two-button panic keys. Select NO to disable the option. Default is NO .
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
17
18
ACTIVATE ZONE 2
BYPASS? NO
ZONE 2 BYPASS
TIME:
RELOCK ZONE 2
CHANGE: NO
40
YES
Activate Zone 2 Bypass (7073/A, 7173 only)
Select YES to activate the zone 2 bypass operation.
Selecting NO allows standard zone operation on zone 2. The default is NO .
Zone 2 Bypass Time (7073/A, 7173 only)
Enter the number of bypass seconds to elapse before the bypass timer expires. Range is 20-250 seconds. Press any select key to enter the number of seconds. Once the door strike relay is activated, the user has five seconds to open the door connected to zone 2. The zone is then bypassed for the programmed time or until the contact restores to normal.
Ten seconds prior to the expiration of the bypass time, the keypad beeps if the door is still open. If the door remains open when the timer expires, a zone open/short is sent to the panel for zone 2. Default is 40 seconds.
Relock on Zone 2 Fault? (7073/A, 7173 only)
Select NO to leave the relay on when zone 2 faults to an open or short condition during bypass. Select YES to turn the relay off when zone 2 faults open or short during bypass.
Default is NO .
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
ACTIVATE ZONE 3
EXIT: NO YES
ZONE 3 REX STRIKE
TIME:
ALL?: NO
DELAY:
5
YES
2
Activate Zone 3 Exit (7073/A, 7173)
Select YES to enable the Request to Exit feature on zone
3. When zone 3 shorts, the keypad relay activates. During this time, the user can open the protected door to start the programmed bypass entry/exit timer. If the door is not opened within the time programmed in the Zone 3 REX
Strike Time, the relay restores the door to its locked state.
No panel programming is required.
Zone 3 REX Strike Time (7073/A, 7173)
Enter the number of REX seconds to elapse. Range is
5-250 seconds. Press any select key to clear the keypad display and enter the number of seconds. The default is 5 .
ALL? NO YES (7063/A, 7073/A, 7163, 7173)
Select the number of seconds (1-9) the keypad should wait when an area system displays ALL? NO YES during arming/disarming or a HOME/SLEEP/AWAY system waits during arming only. If NO or YES , or HOME , SLEEP , or
AWAY is not manually selected before the delay expires, the keypad automatically selects YES or AWAY . Select zero
(0) to disable this feature. The delay also occurs when any credential is presented for arming the Home/Sleep/Away system. Default is 2 .
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
19
20
CUSTOM CARD FORMAT
Note: Custom card format programming options are only available on 7063/A,
7073/A, 7163, and 7173 keypads.
CARD FORMATS
DMP CUSTOM ANY
Card Formats
Select DMP to allow credentials that use a 26-45 bit data string. The menu advances to REQUIRE SITE .
Select CUSTOM to disable DMP format and program slots 1-8 as needed. The menu advances to FORMAT NO .
Select ANY to allow all Wiegand card reads to activate the door strike relay. The door strike relay is activated for the length of time programmed in ZN 3 REX TIME . No user code information is sent to the panel. The menu advances to NO
COMM WITH PNL .
The default card format is DMP .
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
CARD FORMATS
FORMAT NO: -
Card Format Number
Select the slot number (1-8) that you want to program for a custom non-DMP card format. The format that is programmed into slot 1 is the default format. In the event that a card with an unrecognized format is used, that card will be read in the format that is programmed in slot 1. To restrict card reads to specific formats, only program slots 2-8.
See Public Card Formats for some publicly available card formats that can be used with the keypad. Other private or custom formats may also be compatible. Please contact the credential supplier or manufacturer for the bit structure.
Note: If you select slot 1 and you are upgrading from
XR panel version 182 or earlier, FORMAT NAME will automatically be named SINGLE CARD FORMAT and
WIEGAND CODE LENGTH will default to 45.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
21
22
FORMAT NAME
*UNUSED*
WIEGAND CODE
LENGTH: 26
Format Name
Press any select area to rename the card format. Press CMD to save and advance.
Wiegand Code Length
When using a custom credential, enter the total number of bits to be received in Wiegand code including parity bits.
Press any select key or area to enter a number between
1-255 to equal the number of bits. Default is 26 bits.
An access card contains data bits for a site code, user code, and start/stop/parity bits. The starting position, location, and code length must be determined and programmed into the keypad. See Figure 8.
0 1 1 1 0 1 0 1 1 0 1 1 0 1 0 1 0 0 0 1 1 0 0 1 1 1
First Bit
Received
Position = 0
Site Code
Position = 1
User Code
Position = 9
Last Bit
Received
Length = 8 Length = 16 Position = 25
In this example the Wiegand Code Length = 26 bits.
Figure 8: Wiegand Data Stream Bit Location
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
SITE CODE
POS: 1 LEN: 8
USER CODE
POS: 9 LEN: 16
REQUIRE SITE
CODE: NO YES
Site Code Position and Length
Enter the site code start position and length in the data string. Press select area 2 to clear the site code start position and enter a number between 0-255. Press CMD to save.
Default is 1 .
Press select area 4 to clear the site code length and enter a number between 1-24. Press CMD to save. Default is 8 .
User Code Position and Length
Define the user code start bit position and length. Press select area 2 to clear the user code position and enter a number between 0-255. Press CMD to save. Default is 9 .
Press select area 4 to clear the user code length and enter a number between 16-64. Press CMD to save. The default is the
DMP value of 16 .
Require Site Code
Press the top row select key or area under YES to use a site code and press CMD to view the site code entry display.
Press NO to advance to NO OF USER CODE DIGITS . Default is NO .
In addition to user code verification, door access is only granted when any one site code programmed at the SITE
CODE ENTRY option matches the site code received in the
Wiegand string.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
23
24
SITE CODE 1:
NO OF USER CODE
DIGITS: 5
Site Code Display
You can program up to eight 8-digit site codes. The site code range is 0-16,777,214.
In the keypad display, enter site code 1 and press CMD . The display will ask for site code 2 followed by site code 3 and so on. When you have selected the site code you want to change, press CMD.
Number of User Code Digits
The keypad recognizes user codes from 4-12 digits long.
Press any top row select key or area to enter a user code digit length. This number must match the user code number length being programmed in the panel. The device will recommend a number of user code digits based on the user code length. Default is 5 .
All bits are read and converted into a decimal number string.
The number string is left padded with 0 (zero) if needed for long user code lengths.
Example: # decoded 1234567
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
NO COMM WITH PNL
OFF SITE ANY ON
NO COMM WITH PNL
LAST
No Communication with Panel
Define the relay action when communication with the panel has not occurred for 5 seconds. Default is OFF . Press any select key or area to change the default relay action:
Press the first select key or area to choose OFF (Relay
Always Off). The relay does not turn on when any Wiegand string is received. OFF does not affect any REX operation. If communication is lost during a door strike, the relay remains on for the door strike duration but turns off at the end of the door strike timer.
Press the second select key or area to choose SITE (Accept
Site Code). Door access is granted when the Wiegand site code string received matches any site code programmed at
SITE CODE DISPLAY . Refer to REQUIRE SITE CODE for more information.
Press the third select key or area to choose ANY (Any
Wiegand Read). Access is granted when any Wiegand string is received.
Press the fourth select key or area to choose ON (Relay
Always On). The relay is always on. Press CMD to display the next action.
Press the first select key or area to choose LAST (Keep Last
State). The relay remains in the same state and does not change when communication is lost.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
25
KYPD LANGUAGE:
LANG: ENGLSH
KYPD LANGUAGE:
ENG SPN FRN DUT
KYPD LANGUAGE:
EΛΛ CZK
Keypad Language
Define the keypad’s language. Default is ENGLSH .
Press any select key to change the language options.
Press select key 1 to select English. Press select key 2 to select Spanish. Press select key 3 to select French. Press select key 4 to select Dutch.
Press CMD to advance the language options.
Press select key 1 to select Greek. Press select key 2 to select
Czech.
26 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
ADDITIONAL PROGRAMMING
Users can manually enter their user code into the keypad which then verifies the user code and its authority with the panel. The 7073/A and 7173 activate the on-board Form C relay releasing a door strike or magnetic lock. To provide added flexibility, the keypad allows connection of an external Wiegand output compatible reader.
Proximity Credential Compatibility
DMP keypads with internal proximity readers are compatible with most standard 125 kHz proximity credentials. An external 13.56 MHz proximity reader can be connected and will be compatible with 13.56 MHz proximity credentials. For a list of publicly supported card formats, see Public Card Formats.
Note : Some proximity credentials are not compatible with DMP proximity keypads.
Test the intended proximity credentials with the application before installation. DMP does not guarantee compatibility with credentials not purchased from DMP.
Program a Credential
1. Access the User Menu by pressing CMD until MENU? NO YES displays. Choose
YES , and present your proximity credential to the reader or manually enter your user code at the keypad.
2. Press CMD until USER CODES?
displays.
3. Press any select key. Choose ADD .
4. At ENTER CODE: , present the credential to the reader. The keypad works by reading the user code from the data string sent by the access control reader.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
27
TEST THE KEYPAD
Test the keypad to ensure alarm backlighting, individual shortcut keys, and any programmed zones work. To begin testing, access the Installer Options menu. Hold down the back arrow and CMD keys at the same time until SET BRIGHTNESS displays. Enter
3577 and press CMD .
KPD
OPT
KPD
DIAG STOP
Keypad Diagnostics
Press the select key under KPD DIAG . The keypad lights all display segments and illuminates the keyboard in red. The display backlighting then changes to green. The keypad alternates between these two states for approximately two minutes. Press CMD at any time to begin testing individual keys.
PRESS KEY TO
TEST
Test Individual Keys
The display changes to PRESS KEY TO TEST . This option tests each key on the keyboard to ensure it is operating properly. Press and hold each key for two seconds. The key number being held appears in the display. Verify the correct number displays before testing the next key.
28 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
Z1 OPEN
Z3 OPEN
Z2 OPEN
Z4 OPEN
INPUT WIEGAND
Zone Test (7070, 7073/A, 7170, 7173)
This option allows the keypads to display the current electrical status of the four protection zones. The status is shown as OPEN , SHRT , or OKAY . The zone test displays on the other keypads but is not operational.
Input Wiegand (7063/A, 7073/A, 7163, 7173)
This option tests the internal and external reader input from proximity credentials. The display shows OKAY each time a good proximity read is received.
Exiting the Installer Options
When done, press CMD once to return to the Installer Options screen. Press the select key under STOP to exit the Installer Options function.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
29
END USER TRAINING
This section covers 7063/A, 7073/A, 7163, and 7173 keypads and contains three sections:
• Keypad Arming and Disarming
• Keypad Access Control
• Keypad Entry Delay
All of the examples displayed assume that CLOSING CODE is YES in panel programming.
Figures 9 through 12 show the user presenting a card to the keypad. When an external reader is connected to a 7073/A and a 7173 keypad, the user presents a card to the reader rather than to the keypad.
30 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
KEYPAD ARMING AND DISARMING
Area System Arming and Disarming
1. Press CMD until the keypad displays ARM DISARM .
2. Press the select key under the preferred option.
3. The keypad displays ENTER CODE: . The user presents their card to the reader.
Once validated by the system, all areas assigned to that code arm or disarm automatically and the 7073/A and 7173 keypad door strike relay activates. See Figure 9.
ABC SECURITY
ARM DISARM
ABC SECURITY
ENTER CODE: –
ABC SECURITY
ALL? NO YES
Select NO to arm or disarm individual areas.
Select YES, or simply wait, to automatically arm or disarm all areas for which you are authorized.
Figure 9: Area Arming and Disarming
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
31
All/Perimeter System Arming and Disarming
Present the card to the reader or press CMD , the keypad displays DISARM?
or PERIM ALL
(when arming). Press the select key under the desired option. The keypad displays
ENTER CODE: . Present the card to the reader. Once validated by the system, the selected areas arm or disarm automatically. On 7073/A and 7173 keypads, the Door Strike relay then activates.
Home/Away System Arming and Disarming
Present your card to the reader. If the system is armed, once the card is validated, all areas are disarmed and the keypad displays ALL SYSTEM OFF . If the system is disarmed when you present your card, once the card is validated, HOME SLEEP AWAY displays. Manually select HOME , SLEEP , AWAY or after a short time-out, all areas automatically arm in the
AWAY mode.
PERIM ALL
32
The system arms or disarms the areas and activates the door strike relay on the 7073 or 7073A keypad.
Figure 10: All Perimeter Arming and Disarming
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
KEYPAD ACCESS CONTROL
Area and All/Perimeter Door Strike
From the Status List, present your card to the reader. Once the system validates the card, the Door Strike relay activates. Home/Away systems only activate the 7073/A, and 7173
Door Strike relay when arming and disarming.
ABC SECURITY
MON 10:20 AM
While the keypad displays the
Status List, present your access card.
Typically, the relay activates for 5 seconds during which time you can open the door. Once you open the door, you have 40 seconds to exit and close the door before the Zone 2 Bypass expires.
Figure 11: Present Access Card
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
33
KEYPAD ENTRY DELAY
All Systems
Once the entry delay starts, the keypad sounds an entry tone and displays
ENTER CODE: . Present your card to the reader. Once validated, the system disarms all areas accessible by you and activates the 7073/7073A/7173 Door Strike relay. Area systems provide a delay to allow selected areas only to be disarmed. See Keypad Arming and Disarming.
ABC SECURITY
ENTER CODE: –
34
Entry delay starts.
The System disarms the area and activates the Door Strike Relay.
Figure 12: Entry Delay
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
WIRING SPECIFICATIONS
When planning a keypad bus installation, keep in mind the following specifications:
• DMP recommends using 18 or 22 AWG unshielded wire for all keypad and LX-Bus circuits. Do not use twisted pair or shielded wire for LX-Bus and keypad bus data circuits. To maintain auxiliary power integrity when using 22-gauge wire, do not exceed 500 feet. When using 18-gauge wire, do not exceed 1,000 feet. Install an additional power supply to increase the wire length or add devices.
• Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge. This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases.
• Maximum number of devices per 2,500 feet circuit is 40.
Note: Each panel allows a specific number of supervised keypads. Add additional keypads in the unsupervised mode. Refer to the panel installation guide for the specific number of supervised keypads allowed.
• Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2 VDC. If the voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit. When voltage is too low, the devices cannot operate properly.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
35
36
KEYPAD SPECIFICATIONS
MODEL
NORMAL/
STANDBY
CURRENT
ALARM
CURRENT
FOUR
ZONES
INTERNAL
PROX
READER
WIEGAND
INPUT
INTERNAL
DOOR
STRIKE
RELAY
7060/A,
7160
7063/A,
7163
7070/A,
7170
72 mA
85 mA
72 mA+1.6 mA per active zone
7073/A,
7173
85 mA+1.6 mA per active zone
87 mA
100 mA
87 mA+2 mA per active zone
100 mA+2 mA per active zone
X
X
X
X X X
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
PUBLIC CARD FORMATS
CARD
FORMAT
WIEGAND
CODE
LENGTH
H10301 26 BIT 26
H10302 37 BIT
W/FAC
37
37 H10304 37 BIT
W/O FAC
FARPOINTE
39 BIT
39 1
0
1
1
SITE
CODE
POSITION
SITE
CODE
LENGTH
8
16
0
17
1
USER
CODE
POSITION
9
17
18
USER
CODE
LENGTH
16
19
35
20
35 2 12 14 20
5
6
USER
CODE
DIGITS
12
7
6 CORPORATE
1000 35 BIT
CORPORATE
1000 48 BIT
48 2 22 24 23 7
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
37
READERS AND CREDENTIALS
125 KHZ PROXIMITY READERS 125 KHZ PROXIMITY CREDENTIALS
38
P-300
P-500
CASCADE PROXIMITY
READER
ALPS PROXIMITY READER
P-640
MP-5365
MX-5375
PATAGONIA PROXIMITY
READER WITH KEYPAD
MINIPROX™ PROXIMITY
READER
MAXIPROX® PROXIMITY
READER
PP-6005B PROXPOINT® PLUS
PROXIMITY READER
PP-5355 PROXPRO PROXIMITY
READER WITH KEYPAD
PR-5455
TL-5395
PROXPRO® II PROXIMITY
READER
THINLINE II® PROXIMITY
READER
PSC-1
PSK-3
PSM-2P
1306
1326
1346
1351
1386
STANDARD LIGHT
PROXIMITY CARD
PROXIMITY KEY
RING TAG
ISO IMAGEABLE
PROXIMITY CARD
PROX PATCH™
PROXCARD II®
CARD
PROXKEY III®
ACCESS DEVICE
PROXPASS®
ISOPROX II® CARD
Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
13.56 MHZ SMARTCARD READERS
DELTA3
DELTA5
DELTA5.3
DELTA6.4
FARPOINTE SMARTCARD
READER
FARPOINTE SMARTCARD
READER
FARPOINTE SMARTCARD
READER
FARPOINTE SMARTCARD
READER
13.56 MHZ SMARTCARD CREDENTIALS
DC1-1
DM1-3
DE2
DK1-3
FARPOINTE CLAMSHELL
SMARTCARD
FARPOINTE IMAGEABLE
SMARTCARD
FARPOINTE MIFARE®
DESFIRE® EV1
SMARTCARD
FARPOINTE KEY FOB
SMARTCARD
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
39
COMPLIANCE SPECIFICATIONS
ULC Commercial Burglary for XR150/XR550 Series Panels
The keypad zones cannot be used for ULC listed applications.
Specifications
Operating Voltage
Thinline/Aqualite Dimensions
12 VDC
7” W x 5.25” H x 0.5” D
Compatibility
All keypads are compatible with all DMP panels.
Backboxes
695 or 696 Keypad Backbox
Keypad Wiring Harness
300 4-wire harness
300-12 12-wire harness
330 4-wire dual end harness
ACCESSORIES
777 protective keypad cover
300-5 5-wire harness
300-512 12-wire harness, 5 ft. long
40 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
CERTIFICATIONS
California State Fire Marshall (CSFM)
FCC Part 15 RFID Reader FCC ID: CCKPC0086—Thinline and Aqualite
Industry Canada ID: 5251A-PC0086—Thinline and Aqualite
New York City (FDNY COA #6167)—Only for keypads with zones
Underwriters Laboratory (UL) Listed
ANSI/UL 294
Level I
Level IV
ANSI/UL 365
ANSI/UL 609
ANSI/UL 1023
ANSI/UL 1076
ANSI/UL 1610
ANSI/UL 1635
ANSI/UL 985
ANSI/UL 864
ULC 5545
ULC Subject-C1023
ULC/ORD-C1076
ULC S304
Access Control System Units
Destructive Attack and Line Security
Endurance and Standby Power
Police Connected Burglar
Local Burglar
Household Burglar
Proprietary Burglar
Central Station Burglar
Digital Burglar
Household Fire Warning
Fire Protective Signaling
Household Fire
Household Burglar
Proprietary Burglar
Central Station Burglar
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
41
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
42 Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
INDUSTRY CANADA INFORMATION
This device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.
L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé
à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand public.
7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
43
LT-0883 19314 1.04 © 2019 Digital Monitoring Products, Inc.

Public link updated
The public link to your chat has been updated.
Advertisement