Little GIANT 3-MDX is a magnetic driven pump designed to handle mildly corrosive fluids, such as low concentrations of acids and alkalis. It features a glass-filled polypropylene pump head, titanium spindle shaft and thrust washers, and a nitrile O-ring seal. The motor is thermally protected and has a 1/25 horsepower rating.
The 3-MDX is not self-priming and must be operated with the volute intake below the liquid level. It is not submersible and should only be used in the in-line mode. The weight of the pump must be supported adequately, and it should not be allowed to run dry.
The 3-MDX is ideal for use in a variety of applications, including:
advertisement
LIMITED
WARRANTY LITTLE GIANT WARRANTY STATEMENT
LIMITED
WARRANTY
Your Little Giant product is guaranteed to be in perfect condition when it leaves our Factory. It is warranted against defective materials and workmanship for a period of 12 months (90 day warranty on Models 1-AA-OM, GKPK-SC, PP-1,
PPS-1, PP-12, PPS-12, PP-230 and Cooler King) from date of purchase by the user. No warranty on brush wear on
Model 35-OM and impeller or cam in Models PP-1, PP-12, PPS-12 and PP-230. Any product that should fail for either of the above two reasons and is still within the warranty period, will be repaired or replaced if returned prepaid to our Factory. All defective products returned under warranty will be fully inspected to determine “CAUSE OF FAILURE” before any warranty is approved. Little Giant will honor the warranty within the warranty time period specified on satisfactory written proof of purchase.
DISCLAIMER: Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, shall not be relied upon by the user, and are not part of the contract for sale.
Seller’s and manufacturer’s only obligation, and buyer’s only remedy, shall be the replacement and/or repair by the manufacturer of the product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising out of the use or the inability to use the product, and the user agrees that no other remedy shall be available to it. Before using, the user shall determine the suitability of the product for his intended use, and user assumes all risk and liability whatsoever in connection therewith. THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE
WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY, EXPRESSED OR IMPLIED,
WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED, INCLUDING, BUT NOT
LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Warranty will be VOID if any of the following conditions are found:
1.
Sealed motor housing opened.
2.
Product connected to voltage other than indicated on name plate.
3.
Cord cut off to a length less than three feet.
4.
Pump allowed to operate dry (fluid supply cut off).
5.
Pump used to circulate anything other than fresh water, light oils, or other mild liquids at approximately room temperature.
6.
Product abuse by customer.
The National Electric Code requires a Ground Fault circuit interrupter (GFCI) be installed in the branch circuit supplying fountain equipment rated above 15 volts. Part number 599335, GFCI-1, is in stock and we recommend each pump be used with a GFCI.
KEEP THIS FOLDER
File this for safe keeping. It may be valuable to you for service under the term of the warranty.
Model # ____________________________________________Date of Purchase __________________________
Catalog # __________________________________________Serial # ___________________________________
Name of Dealer _______________________________________________________________________________
LITTLE GIANT PUMP COMPANY
3810 N. Tulsa St. • P. O. Box 12010 • Oklahoma City, OK 73112
Phone (405) 947-2511 • Fax (405) 947-8720
INSTRUCTIONS AND
REPAIR PARTS FOR
3X-MDX
3-MDX
• INSTALLATION
• OPERATION
• MAINTENANCE
• REPAIR PARTS
INTRODUCTION
This instruction sheet will provide you with information required to safely own and operate the Little Giant MD series pumps. The pump you have purchased is a magnetic driven pump. These “MD” series pumps handle most mildly corrosive fluids such as low concentrations of acids and alkalis in pH range of
5 to 9 at fluid temperatures up to 150ºF. The pump head parts are made of glass filled polypropylene. The spindle shaft and thrust washers are titanium. The impeller driven magnet is uncoated ceramagnet A
(barium ferrite) type ceramic. O-ring seals are nitrile. The motor is thermally protected.
This instruction sheet covers the standard models in this pump series. This form is applicable to other models in this series not listed by catalog number in the replacement parts list section of this pamphlet. If the catalog number of your pump is not listed in the replacement parts section, then caution should be exercised when ordering replacement parts. Always give the catalog number of your pump when ordering replacement parts.
The Little Giant unit you have purchased is of the highest quality workmanship and material. It has been engineered to give you long and trouble-free service.
The Little Giant pumps are carefully inspected, tested, and packaged to insure safe operation and delivery. When you receive your pump, examine it carefully to determine that there are no broken or damaged parts that may have occurred during shipment. If damage has occurred, make notation and notify the firm from which you purchased the pump. They will assist you in the replacement or repair, if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERV-
ICE THE LITTLE GIANT PUMP, KNOW THE PUMP APPLICATIONS, LIMITATIONS, AND POTENTIAL
HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
SAFETY GUIDELINES
DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL,
KEROSENE, ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES. PUMP SHOULD ONLY BE USED
WITH LIQUIDS COMPATIBLE WITH PUMP COMPONENT MATERIALS.
DO NOT HANDLE PUMP WITH WET HANDS OR WHEN STANDING ON A WET OR DAMP SUR-
FACE, OR IN WATER.
THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND/OR GROUNDING TYPE AT-
TACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CON-
NECTED TO A PROPERLY GROUNDED GROUNDING TYPE RECEPTACLE.
THE NATIONAL ELECTRIC CODE REQUIRES A GROUND FAULT CIRCUIT INTERRUPTER
(GFCI) BE INSTALLED IN THE BRANCH CIRCUIT SUPPLYING FOUNTAIN EQUIPMENT, POOLS,
ETC.
IN ANY INSTALLATION WHERE PROPERTY DAMAGE AND/OR PERSONAL INJURY MIGHT RE-
SULT FROM AN INOPERATIVE OR LEAKING PUMP DUE TO POWER OUTAGES, DISCHARGE LINE
BLOCKAGE, OR ANY OTHER REASON, A BACKUP SYSTEM(S) AND/OR ALARM SHOULD BE
USED.
SUPPORT PUMP AND PIPING WHEN ASSEMBLING AND WHEN INSTALLED. FAILURE TO DO
SO MAY CAUSE PIPING TO BREAK, PUMP TO FAIL, MOTOR BEARING FAILURES, ETC.
©Copyright 2003Little Giant Pump Company Form 993310–6/03
:
MODEL
NO.
INTAKE
SIZE
DISCH.
SIZE
VOLTS HERTZ RPM
MOTOR
PH.
H.P.
3X-MDX 5/8" O.D. 5/8" O.D.
3-MDX 5/8" O.D. 5/8" O.D.
115
115
60
60
1550
3000
1
1
1/50
1/25
KEY:OPEN=Open Motor—FC=Fan Cooled
NOTE: Performance Data Shown In Table Above Is For 115 Volt 60 Hertz Operation
ELECTRICAL CONNECTIONS
SPECIFICATIONS
WATTS
67
126
AMPS
MOTOR
TYPE
.94
1.65
OPEN FC
OPEN FC
MAX.
PSI
3.0
8.2
SHUT
OFF
HEAD
(FT.)
7.0
19.0
1 FT.
5.8
7.6
GALLONS PER MINUTE
3 FT.
6 FT.
9 FT.
5.0
7.0
3.3
6.8
–
6.0
12 FT.
–
5.0
HT.
DIMENSIONS
WD.
LG.
5.13
5.13
3.75
3.75
7.63
8.38
WT.
PACKED
(LBS.)
6.2
7.0
Check the pump label for proper voltage required. Do not connect to voltage other than that shown.
If pump is supplied with a 3-prong electrical plug, the third prong is to ground the pump to prevent possible electrical shock hazard. DO NOT REMOVE the third prong from the plug. A separate branch circuit is recommended. Do not use an extension cord. Do not cut plug from the cord. If the plug is cut or the cord is shortened, then this action will void the warranty.
If the cord is equipped with stripped lead wires, such as on 230v models, be sure that the lead wires are connected to a power source correctly. The green/yellow wire is the ground, the other two are live.
NOTE: Motor configuration may vary from model to model.
OPERATION
The pump is supplied completely preassembled and pretested from the factory. Make sure the wing nuts are tight before operating the pump.
Use a thread sealer on all pipe connections and hand tighten only.
The pump is not self priming. It must be operated with the volute intake below the liquid level.
This pump is not submersible. Operate the pump only in the in-line mode. DO NOT put the unit in liquid. Pump should be located in a well ventilated area and away from where accidental water spillage would cause wetting of the pump.
The weight of the pump must be supported adequately. DO NOT support the pump by the intake and discharge connections alone.
Do not allow the pump to run dry (without liquid). Heat build up caused by friction will damage the pump parts when dry.
Do not attempt to restrict the intake side of these pumps. Restricting the intake may cause damage to the pump head. If you require reduced flow rates, then place a valve on the discharge side of the pump or if flexible vinyl tubing is used, a clamp can be used on the tubing to restrict the flow.
If the unit is going to be idle for a period of time, follow the cleaning instructions outlined in the next section. Do not let the unit freeze in the wintertime. This may cause cracking or distortion that may destroy the unit.
SERVICE INSTRUCTIONS
MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER SOURCE BEFORE
ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT.
The motor’s sleeve bearings should be lubricated every six months with two to three drops of S.A.E.
20 weight non-detergent oil. The oil holes are located on top at each end of the motor.
All wetted parts can be serviced by removing the (4) wing nuts (item 11) which hold the volute to the housing. The pump head components can easily be replaced in the field if necessary.
Lightly clean any corrosion or debris which may clog the impeller.
If pump is tripping circuit breakers, GFCI, or not operating properly after cleaning, return to Little Giant or its authorized service center. DO NOT attempt repairs yourself.
Be certain power cord is in good condition and contains no nicks or cuts.
PARTS LIST MODEL & CATALOG NO.
ITEM
NO.
7
8
9
10
11
12
6
6
4
5
2
3
1
1
181111
181112
180058
921067
924007
901418
920003
901424
MFR’S
PART
NO.
977314
977313
181411
181211
181311
180602
PART DESCRIPTION
MOTOR, 115V
MOTOR, 115V
MAGNET HOUSING BRACKET
VOLUTE
BACKPLATE SEPARATOR
DRIVE MAGNET ASSEMBLY
IMPELLER/MAGNET ASSEMBLY
IMPELLER/MAGNET ASSEMBLY
SHAFT
THRUST WASHER
O-RING
MACHINE SCREW, #8-32 X 1½"
WING NUT, #8-32
MACHINE SCREW, #8-32 X ½"
QTY.
1
4
1
2
4
4
1
1
1
1
1
1
1
1
3X-MDX
581030
•
•
•
•
•
•
•
•
•
•
•
•
3-MDX
581031
•
•
•
•
•
•
•
•
•
•
•
•
13 921059 LOCK WASHER, #8 4 • •
Parts list applies to products shown. Other models are available, however, parts may vary. For other models, contact Parts Depot, Factory or Distributor for replacement parts. Be sure to give the six digit product number and model number when requesting parts.