Installation, Operation, and Maintenance Manual
Model API 3171 Flood Oil Lubrication
Table of Contents
Table of Contents
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 1
Table of Contents
2
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Table of Contents
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 3
Introduction
Introduction
Purpose of this manual
The purpose of this manual is to provide necessary information for:
• Installation
• Operation
• Maintenance
CAUTION:
Failure to observe the instructions contained in this manual could result in personal injury and property damage, and may void the warranty. Read this manual carefully before installing and using the product.
NOTICE:
Save this manual for future reference and keep it readily available.
4 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Safety
Safety
WARNING:
• The operator must be aware of the pumpage and take appropriate safety precautions to prevent physical injury.
• Risk of serious injury or death. If any pressure-containing device is over-pressurized, it can explode, rupture, or discharge its contents. It is critical to take all necessary measures to avoid over-pressurization.
• Risk of death, serious personal injury, and property damage. Installing, operating, or maintaining the unit using any method not prescribed in this manual is prohibited.
Prohibited methods include any modification to the equipment or use of parts not provided by ITT. If there is any uncertainty regarding the appropriate use of the equipment, please contact an ITT representative before proceeding.
• Risk of serious personal injury. Applying heat to impellers, propellers, or their retaining devices can cause trapped liquid to rapidly expand and result in a violent explosion. This manual clearly identifies accepted methods for disassembling units. These methods must be adhered to. Never apply heat to aid in their removal unless explicitly stated in this manual.
• If the pump or motor is damaged or leaking, electric shock, fire, explosion, liberation of toxic fumes, physical harm, or environmental damage may result. Do not operate the unit until the problem has been corrected or repaired.
• Risk of serious personal injury or property damage. Dry running may cause rotating parts within the pump to seize to non-moving parts. Do not run dry.
• Risk of death, serious personal injury, and property damage. Heat and pressure buildup can cause explosion, rupture, and discharge of pumpage. Never operate the pump with suction and/or discharge valves closed.
CAUTION:
• Risk of injury and/or property damage. Operating a pump in an inappropriate application can cause over pressurization, overheating, and/or unstable operation. Do not change the service application without the approval of an authorized ITT representative.
Safety terminology and symbols
About safety messages
It is extremely important that you read, understand, and follow the safety messages and regulations carefully before handling the product. They are published to help prevent these hazards:
• Personal accidents and health problems
• Damage to the product
• Product malfunction
Hazard levels
Hazard level
DANGER:
Indication
A hazardous situation which, if not avoided, will result in death or serious injury
WARNING:
A hazardous situation which, if not avoided, could result in death or serious injury
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 5
6
Safety
Hazard level
CAUTION:
Indication
A hazardous situation which, if not avoided, could result in minor or moderate injury
NOTICE:
• A potential situation which, if not avoided, could result in undesirable conditions
• A practice not related to personal injury
Hazard categories
Hazard categories can either fall under hazard levels or let specific symbols replace the ordinary hazard level symbols.
Electrical hazards are indicated by the following specific symbol:
Electrical Hazard:
The Ex symbol
These are examples of other categories that can occur. They fall under the ordinary hazard levels and may use complementing symbols:
• Crush hazard
• Cutting hazard
• Arc flash hazard
The Ex symbol indicates safety regulations for Ex-approved products when used in atmospheres that are potentially explosive or flammable.
Environmental safety
The work area
Always keep the station clean to avoid and/or discover emissions.
Waste and emissions regulations
Observe these safety regulations regarding waste and emissions:
• Appropriately dispose of all waste.
• Handle and dispose of the processed liquid in compliance with applicable environmental regulations.
• Clean up all spills in accordance with safety and environmental procedures.
• Report all environmental emissions to the appropriate authorities.
WARNING:
If the product has been contaminated in any way, such as from toxic chemicals or nuclear radiation, do NOT send the product to ITT until it has been properly decontaminated.
Electrical installation
For electrical installation recycling requirements, consult your local electric utility.
Recycling guidelines
Always follow local laws and regulations regarding recycling.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Safety
User safety
General safety rules
These safety rules apply:
• Always keep the work area clean.
• Pay attention to the risks presented by gas and vapors in the work area.
• Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash hazards.
• Always bear in mind the risk of drowning, electrical accidents, and burn injuries.
Safety equipment
Use safety equipment according to the company regulations. Use this safety equipment within the work area:
• Helmet
• Safety goggles, preferably with side shields
• Protective shoes
• Protective gloves
• Gas mask
• Hearing protection
• First-aid kit
• Safety devices
Electrical connections
Electrical connections must be made by certified electricians in compliance with all international, national, state, and local regulations. For more information about requirements, see sections dealing specifically with electrical connections.
Precautions before work
Observe these safety precautions before you work with the product or are in connection with the product:
• Provide a suitable barrier around the work area, for example, a guard rail.
• Make sure that all safety guards are in place and secure.
• Recognize the site emergency exits, eye wash stations, emergency showers and toilets.
• Allow all system and pump components to cool before you handle them.
• Make sure that you have a clear path of retreat.
• Make sure that the product cannot roll or fall over and injure people or damage property.
• Make sure that the lifting equipment is in good condition.
• Use a lifting harness, a safety line, and a breathing device as required.
• Make sure that the product is thoroughly clean.
• Make sure that there are no poisonous gases within the work area.
• Make sure that you have quick access to a first-aid kit.
• Disconnect and lock out power before servicing.
• Check the explosion risk before you weld or use electric hand tools.
Wash the skin and eyes
1. Follow these procedures for chemicals or hazardous fluids that have come into contact with your eyes or your skin:
Condition
Chemicals or hazardous fluids in eyes
Action
1.
Hold your eyelids apart forcibly with your fingers.
2.
Rinse the eyes with eyewash or running water for at least 15 minutes.
3.
Seek medical attention.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 7
8
Safety
Condition
Chemicals or hazardous fluids on skin
Action
1.
Remove contaminated clothing.
2.
Wash the skin with soap and water for at least 1 minute.
3.
Seek medical attention, if necessary.
Ex-approved products
Follow these special handling instructions if you have an Ex-approved unit.
Personnel requirements
These are the personnel requirements for Ex-approved products in potentially explosive atmospheres:
• All work on the product must be carried out by certified electricians and ITT-authorized mechanics. Special rules apply to installations in explosive atmospheres.
• All users must know about the risks of electric current and the chemical and physical characteristics of the gas, the vapor, or both present in hazardous areas.
• Any maintenance for Ex-approved products must conform to international and national standards (for example, IEC/EN 60079-17).
ITT disclaims all responsibility for work done by untrained and unauthorized personnel.
Product and product handling requirements
These are the product and product handling requirements for Ex-approved products in potentially explosive atmospheres:
• Only use the product in accordance with the approved motor data.
• The Ex-approved product must never run dry during normal operation. Dry running during service and inspection is only permitted outside the classified area.
• Before you start work on the product, make sure that the product and the control panel are isolated from the power supply and the control circuit, so they cannot be energized.
• Do not open the product while it is energized or in an explosive gas atmosphere.
• Make sure that thermal contacts are connected to a protection circuit according to the approval classification of the product, and that they are in use.
• Intrinsically safe circuits are normally required for the automatic level-control system by the level regulator if mounted in zone 0.
• The yield stress of fasteners must be in accordance with the approval drawing and the product specification.
• Do not modify the equipment without approval from an authorized ITT representative.
• Only use parts that are provided by an authorized ITT representative.
Description of ATEX
The ATEX directives are a specification enforced in Europe for electrical and non-electrical equipment installed in Europe. ATEX deals with the control of potentially explosive atmospheres and the standards of equipment and protective systems used within these atmospheres. The relevance of the ATEX requirements is not limited to Europe. You can apply these guidelines to equipment installed in any potentially explosive atmosphere.
Guidelines for compliance
Compliance is fulfilled only when you operate the unit within its intended use. Do not change the conditions of the service without the approval of an ITT representative. When you install or maintain explosion proof products, always comply with the directive and applicable standards
(for example, IEC/EN 60079–14).
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Product warranty
Product warranty
Coverage
ITT undertakes to remedy faults in products from ITT under these conditions:
• The faults are due to defects in design, materials, or workmanship.
• The faults are reported to an ITT representative within the warranty period.
• The product is used only under the conditions described in this manual.
• The monitoring equipment incorporated in the product is correctly connected and in use.
• All service and repair work is done by ITT-authorized personnel.
• Genuine ITT parts are used.
• Only Ex-approved spare parts and accessories authorized by ITT are used in Ex-approved products.
Limitations
The warranty does not cover faults caused by these situations:
• Deficient maintenance
• Improper installation
• Modifications or changes to the product and installation made without consulting ITT
• Incorrectly executed repair work
• Normal wear and tear
ITT assumes no liability for these situations:
• Bodily injuries
• Material damages
• Economic losses
Warranty claim
ITT products are high-quality products with expected reliable operation and long life. However, should the need arise for a warranty claim, then contact your ITT representative.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 9
Transportation and Storage
Transportation and Storage
Inspect the delivery
Inspect the package
1. Inspect the package for damaged or missing items upon delivery.
2. Note any damaged or missing items on the receipt and freight bill.
3. File a claim with the shipping company if anything is out of order.
If the product has been picked up at a distributor, make a claim directly to the distributor.
Inspect the unit
1. Remove packing materials from the product.
Dispose of all packing materials in accordance with local regulations.
2. Inspect the product to determine if any parts have been damaged or are missing.
3. If applicable, unfasten the product by removing any screws, bolts, or straps.
For your personal safety, be careful when you handle nails and straps.
4. Contact your sales representative if anything is out of order.
Transportation guidelines
Pump handling
WARNING:
Dropping, rolling or tipping units, or applying other shock loads, can cause property damage and personal injury. Ensure that the unit is properly supported and secure during lifting and handling.
CAUTION:
Risk of injury or equipment damage from use of inadequate lifting devices. Ensure lifting devices (such as chains, straps, forklifts, cranes, etc.) are rated to sufficient capacity.
Lifting methods
WARNING:
• Risk of serious personal injury or equipment damage. Proper lifting practices are critical to safe transport of heavy equipment. Ensure that practices used are in compliance with all applicable regulations and standards.
• Safe lifting points are specifically identified in this manual. It is critical to lift the equipment only at these points. Integral lifting eyes or eye bolts on pump and motor components are intended for use in lifting the individual components only.
• Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting and handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed shoes, gloves, etc.) at all times. Seek assistance if necessary.
• Assembled units and their components are heavy. Failure to properly lift and support this equipment can result in serious physical injury and/or equipment damage. Lift equipment only at the specifically identified lifting points. Lifting devices such as swivel hoist rings, shackles, slings and spreaders must be rated, selected, and used for the entire load being lifted.
Use swivel hoist rings (available as an option) and suitable slings in order to lift the pump, without motor, to a vertical position and then lower the unit into the sump. Then use the lifting lugs on the motor and a suitable sling in order to hoist the motor into position. Use a tag line attached to the casing end in order to prevent the pump from swinging.
10 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Transportation and Storage
Examples
Figure 1: Example of lifting motor properly with lifting lugs
Figure 2: Example of lifting pump properly with sling
Storage guidelines
Pump storage requirements
Requirements
Vertical pumps require proper preparation for storage and regular maintenance during storage.
The pump is considered in storage when it has been delivered to the job site and is awaiting installation.
For specific requirements for storing motors, gearheads, and engines, contact the equipment manufacturer.
Storage preparation
Condition
Indoor storage area (preferred)
Proper preparation
• Pave the area.
• Clean the area.
• Drain the area and keep it free from flooding.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 11
Transportation and Storage
Condition
Outdoor storage area (when indoor storage is not available)
Placement of pumps and component parts
Stacking of units or component parts
Rotation of the pump
Controlled storage facilities
Uncontrolled storage facilities that have uneven temperatures, higher humidity, and/or dusty conditions)
Proper preparation
• Observe all indoor storage requirements.
• Use weather-proof coverings such as flame-resistant sheeting or tarpaulins.
• Place coverings in a manner that maximizes drainage and air circulation.
• Tie coverings down in order to protect the pump from wind damage.
• Place the unit on skids, pallets, or shoring higher than 15 cm | 6 in. from the ground for good air circulation.
• Sort the parts in order to permit easy access for inspection and/or maintenance without excessive handling.
• Make sure that racks, containers, or crates bear the full weight of units or parts in order to prevent distortion.
• Keep identification markings readily visible.
• Immediately replace any cover you remove for internal access.
• Rotate the shaft counterclockwise once a month, at a minimum.
• Never leave the shaft in a previous position or in the extreme raised or lowered lateral position.
• Make sure that the shaft rotates freely.
• Maintain an even temperature of 6°C | 10°F or higher above the dew point.
• Keep the relative humidity to less than 50%.
• Make sure that there is little or no dust.
• Inspect the unit periodically to make sure that all preservatives are intact.
• Seal all pipe threads and flanged pipe covers with tape.
When pump is not in regular operation
If a pump has been installed, but is not in regular operation for an extended period of time, such as during a seasonal shutdown, then operate it for at least 15 minutes every two weeks.
Prepare the pump for long-term storage
For storage periods over six months, you must follow the
Pump storage requirements (page
1. Inspect the lube-oil and seal-flush piping and either fill the piping with rust-preventative oil, or recoat the piping periodically in order to prevent corrosion.
2. Place 4.5 kg | 10 lbs of moisture-absorbing desiccant or 2.3 kg | 5.0 lbs of vapor-phase inhibitor crystals near the center of the pump.
3. If the unit is assembled, place an additional 0.5 kg | 1 lb in the discharge nozzle and securely fasten the nozzle to the discharge elbow.
4. Install a moisture indicator near the perimeter of the unit.
5. Cover the unit with black polyethylene with a minimum thickness of 0.15 mm | 6.0 mil, and seal it with tape.
6. Provide a small ventilation hole approximately 12.0 mm | 0.5 in. diameter.
7. Provide a roof or shed shelter in order to protect the unit from direct exposure to the elements.
8. If a vertical pump will be stored in a horizontal position, be sure to support the pump sufficiently to avoid any deformation or bending of the pump.
12 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
General description
General description
Product description
The Model API 3171 is a vertical submerged bearing sump and process pump that meets the requirements of the 11th edition of API Standard 610 (ISO 13709).
This model is based on three bearing frames with 17 hydraulic sizes.
This table shows the number of hydraulic sizes available for each drive-unit size group. Note that each pump has a choice of two different discharge pipes which results in four combinations.
Drive-unit size group
S/ST
M/MT
L
Number of hydraulic sizes
9
10
2
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure that the code classifications on the pump are compatible with the specific environment in which the equipment is to be installed. If they are not compatible, do not operate the equipment and contact an ITT representative before proceeding.
Casing
The casing has these features:
• A tangential discharge
• Is self-venting
• Has an integral bearing retainer
• Is precision-bored in order to ensure permanent alignment between the column casing, suction cover, and bearing
Impeller
The impeller is fully open, keyed to the shaft, and held in place by a self-locking capscrew in order to ensure positive locking and prevent damage from reverse rotation. Impellers are spinbalanced (single plane) to ISO G2.5. The impeller is provided with back vanes in order to reduce the axial thrust and prevent the entrance of solids.
The impellers on this pump do not meet the dimensional requirements for dynamic balancing.
Impeller clearance changes are accomplished by means of the EZ-Adjust (TM) bearing carrier
(Patent Pending).
Strainer
Discharge elbow
The discharge elbow is designed to allow the pump to fit into the smallest possible opening. A threaded connection to the discharge pipe allows the pipe to be changed without removing the pump from the sump.
Column pipe
The flat plate strainer is designed to maximize draw-down in a given sump depth. Openings are sized to prevent the entrance of large solids that are commonly found in open sumps.
The column pipe has flanged connections that are machined in order to ensure true parallelism and to maintain steady bearings concentric with the shaft.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 13
General description
Shaft
The standard design uses a one-piece shaft in order to ensure accurate alignment. The shaft is precision-ground, polished, and straightened to keep vibration and deflection to a minimum.
Standard bearing spans keep the shaft well below first critical speed for all sizes.
Bearings
The thrust bearing is flood oil lubricated and consists of a pair of single-row, angular contact ball bearings arranged back-to back. The bearing is shouldered and locked to the bearing carrier and thrust bearing frame. This enables the bearing to carry all of the thrust loads and some of the radial load. All fits are precision-machined to industry standards. The steady bearings are press fit sleeve bearings. Fits are designed for optimum life under all operating conditions.
Thrust Bearing Frame
• Flood-oil lubrication is standard.
• No machining is required to convert from oil to oil-mist lubrication.
• Oil-mist lubrication is optional.
• The oil level is checked through a sight glass.
• The power end is sealed with labyrinth seals.
• Carbon steel construction and precision-machined
• The power end is made in the following sizes:
• S
• M
• L
Seals
Seal type
Upper labyrinth seal
Carbon PTFE casing collar
Description
This seal is used to exclude contaminants from the thrust bearing.
This seal is installed immediately behind the impeller in the casing in order to minimize recirculation back to the sump and maximize hydraulic efficiency.
Motor support
Motor supports are steel construction and precision-machined in order to maintain proper alignment between the motor and pump shaft. Motor supports are designed for NEMA/IEC vertical C-face as standard. It is also designed to keep the bearing frame elevated from the mounting plate allowing air to circulate for increased cooling. It also facilitates removal of bearing frame and mechanical seal without disturbing the motor.
Direction of rotation
The shaft rotates clockwise when you look down on the pump shaft.
Enclosed lineshaft
The enclosed lineshaft design lends itself well for applications where abrasives are present in the pumped fluid, or when a bearing lubricant other than the pumped fluid is required.
Lubrication system
CAUTION:
The fluid must run continuously to ensure flow out of the column at all times. If the flush stops, the fluid in the sump can back up into the column. This contaminates the bearings.
14 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
General description
The main feature of this modified design is a positive lubrication system for all bearings. This design requires a minimum of lubrication fluid due to the bushing located at the bottom of the column adapter housing directly above the impeller.
Acceptable leak rates
Leaks (flows) across the bushing for certain pressure differentials are shown in this table.
Higher pressures will result in higher leaks.
Table 1: Bushing leak rate
Pressure differential (PSI)
3.0
5.0
7.5
Approximate leak rate (GPM)
0.33
0.44
0.60
Standard materials of construction
• Floating bushings are 18-8 stainless steel housing and spring with a glass-filled PTFE bushing.
• Flush tubing is steel.
Drawing
Positive flow must be maintained at all times.
1. Flush Inlet connection 1/4 pressure = 3 PSI + "P" PSI
2. Maximum liquid level "P" PSI above suction
NOTICE:
Grease lubricated bearing frame used for illustration purposes
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 15
General description i-ALERT ® 2 Equipment Condition Monitor
General description i-ALERT
®
2 Equipment
Condition Monitor
Description
The i-ALERT ® 2 Equipment Condition Monitor is a compact, battery-operated monitoring device that continuously measures the vibration and temperature of the pump power end. The i-
ALERT ® 2 sensor uses blinking red LEDs and wireless notification to alert the pump operator when the pump exceeds vibration and temperature limits. This allows the pump operator to make changes to the process or the pump before a catastrophic failure occurs. The Condition
Monitor is also equipped with a single green LED to indicate when it is operational and has sufficient battery life. (i-ALERT ® 2 Bluetooth Equipment Condition Monitor option available. The i-ALERT®2 monitor allows customers to identify potential problems before they become costly failures. It tracks vibration, temperature and run-time hours and wirelessly syncs the data with a smart phone or tablet the i-ALERT®2 mobile app. More information available on
More information available on
16 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Nameplate information
Nameplate information
Important information for ordering
Every pump has a nameplate that provides information about the pump. The nameplate is located on the motor support.
When you order spare parts, identify this pump information:
• Model
• Size
• Serial number
• Item numbers of the required parts
Item numbers can be found in the spare parts list.
Refer to the nameplate on the pump casing for most of the information. See Parts List for item numbers.
Nameplate on the pump casing using English units
Figure 3: Nameplate on the pump casing using English units
Table 2: Explanation of nameplate on the pump casing
Nameplate field
IMPLR. DIA.
MAX. DIA.
GPM
Explanation
Impeller diameter, in inches
Maximum impeller diameter, in inches
Rated pump flow, in gallons per minute
FT HD
RPM
MOD.
SIZE
STD. NO.
MAT L. CONST.
SER. NO.
MAX DSGN PSI @
100ºF
Rated pump head, in feet
Rated pump speed, revolutions per minute
Pump model
Size of the pump
ANSI standard designation
Material of which the pump is constructed
Serial number of the pump
Maximum pressure at 100ºF according to the pump design
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 17
Nameplate information
Nameplate on the pump casing using metric units
Figure 4: Metric units - nameplate on pump casing
Table 3: Explanation of the nameplate on the pump casing
Nameplate field
IMPLR. DIA.
Explanation
Impeller diameter
MAX. DIA.
M 3 /HR
M HD
RPM
MOD.
SIZE
STD. NO.
MAT L. CONST
SER. NO.
MAX. DSGN KG/CM 3 @ 20°C
Maximum impeller diameter
Rated pump flow, in cubic meters per hour
Rated pump head, in meters
Rated pump speed, in revolutions per minute
Pump model
Size of the pump
ANSI standard designation
Material of which the pump is constructed
Serial number of the pump
Kilograms per cubic centimeter at 20°C
ATEX nameplate
All pumping unit (pump, seal, flexible coupling, motor and pump accessories) certified for use in an ATEX classified environment, are identified by an ATEX tag secured to the pump or the sub base on which it is mounted. A typical tag would look like this:
Figure 5: ATEX nameplate
Nameplate field
II
2
G/D
T4
Explanation
Group 2
Category 2
Use when gas and dust are present
Temperature class
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure that the code classifications on the pump are compatible with the specific environment in which the equipment is to be installed. If they are not compatible, do not operate the equipment and contact an ITT representative before proceeding.
The code classification marked on the equipment must be in accordance with the specified area where the equipment will be installed. If it is not, do not operate the equipment and contact your ITT Goulds Pumps sales representative before proceeding.
18 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Permissible temperatures
Permissible temperatures
Code
T1
T2
T3
T4
T5
T6
Maximum permissible surface temperature
450°C | 842°F
300°C | 572°F
200°C | 392°F
135°C | 275°F
100°C | 212°F
85°C | 185°F
Maximum permissible liquid temperature
372°C | 700°F
277°C | 530°F
177°C | 350°F
113°C | 235°F
Option not available
Option not available
NOTICE:
The code classification marked on the equipment must be in accordance with the specified area where you plan to install the equipment. If it is not, contact your ITT representative before you proceed.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 19
Installation
Installation
Pre-installation
Precautions
WARNING:
• When installing in a potentially explosive environment, ensure that the motor is properly certified.
• All equipment being installed must be properly grounded to prevent unexpected discharge. Discharge can cause equipment damage, electric shock, and result in serious injury. Test the ground lead to verify it is connected correctly.
NOTICE:
• Electrical connections must be made by certified electricians in compliance with all international, national, state and local regulations.
• Supervision by an authorized ITT representative is recommended to ensure proper installation. Improper installation may result in equipment damage or decreased performance.
Inspect the pump
1. Remove the plastic shipping plugs from the vent holes in the head column and the casing.
20
"A" represents the location of the plugs
Figure 6: Pump plug locations
2. Remove all the equipment from the shipping containers.
3. Completely clean the underside of the support plate and both sides of the optional pit cover, if supplied.
4. Remove any grease from the machined surfaces.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Installation
Pump location guidelines
WARNING:
Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting and handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed shoes, gloves, etc.) at all times. Seek assistance if necessary.
Safe lifting points are specifically identified in this manual. It is critical to lift the equipment only at these points. Integral lifting eyes or eye bolts on pump and motor components are intended for use in lifting the individual components only.
Guideline
Make sure that the space around the pump is sufficient.
If you require lifting equipment such as a hoist or tackle, make sure that there is enough space above the pump.
Explanation/comment
This facilitates ventilation, inspection, maintenance, and service.
This makes it easier to properly use the lifting equipment and safely remove and relocate the components to a safe location.
Protect the unit from weather and water damage due to rain, flooding, and freezing temperatures.
Do not install and operate the equipment in closed systems unless the system is constructed with properly-sized safety devices and control devices.
This is applicable if nothing else is specified.
Acceptable devices:
• Pressure relief valves
• Compression tanks
• Pressure controls
• Temperature controls
• Flow controls
If the system does not include these devices, consult the engineer or architect in charge before you operate the pump.
Take into consideration the occurrence of unwanted noise and vibration.
The best pump location for noise and vibration absorption is on a concrete floor with subsoil underneath.
Concrete foundation requirements
Requirements
Make sure that you meet these requirements when you prepare the pump foundation:
• The foundation must be able to absorb any vibration.
• The foundation must be able to form a permanent and rigid support for the pumping unit.
• The foundation must be of adequate strength in order to support the complete weight of the pump and driver, plus the weight of the liquid that passes through it.
• There should be at least 12.7 mm | 0.5 in. clearance between the sides of the pump and any portion of the pit.
Typical installation
A typical installation has these characteristics:
• Bolts with a pipe sleeve that is two and a half times the size of the bolt diameter embedded in the concrete
• Properly sized
• Located in accordance with the dimensions given in the example drawing
• Enough space inside the pipe sleeves to allow the final position of the foundation bolts to align with the holes in the sub-base flange
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 21
Installation
1. Hex nut
2. Washer
3. Support plate
4. 12.5 mm | 0.5 in. anchor bolt
5. Anchor bolt sleeve
6. Foundation (by customer)
Figure 7: Example of a typical installation
Support plate installation
Install the support plate with a pit cover
If access to the bottom of the pit cover is not possible during the installation process, you must assemble and install the pump (without the motor), support plate, and pit cover as a unit. You must install the pit cover perfectly level in order to make sure that the pump remains straight up and down when installed.
The vapor-proof option includes machined, gasketed fits between the support plate/pit cover and the pit cover/foundation. You must install these gaskets in order to ensure emissions performance. Bolt the pit cover to a metal sole plate with a machined surface in order to ensure an air tight seal.
1. Carefully lower the pit cover onto the foundation bolts.
2. Use as long a level as possible in order to level the pit cover in all directions with shims or wedges.
3. Hand tighten the anchor bolts. Check the level and re-shim if necessary.
4. Tighten all anchor bolts in a star pattern in order to avoid distorting the pit cover.
5. If access to the bottom side is possible, carefully lower the pump and support plate onto the pit cover.
6. Install all bolts and hand tighten.
7. Check the level on the support plate and re-shim if necessary.
8. Tighten all bolts in a star pattern in order to avoid distorting the support plate.
Install the support plate without a pit cover
1. Carefully lower the pump and support plate onto the foundation bolts.
2. Level the support plate in all directions using shims and wedges.
3. If you use the vapor-proof option, then perform one of these actions in order to make sure that you have an air-tight seal:
Action Support plate type
Standard Insert the supplied gasket between the two flanges. Bolt the support plate to a metal sole plate that has a machined surface.
22 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Installation
Support plate type
Tank flange
Action
Install the supplied gasket between the two flanges. Make sure that the mating flange on the tank is level. Use gasket material between the flanges in order to make minor adjustments.
Figure 8: Layout for a standard support plate with the vapor-proof option
4. Hand tighten the anchor bolts. Check the level and re-shim if necessary.
5. Tighten all anchor bolts in a star pattern in order to avoid distorting the support plate.
Motor support and seal cover installation
The Motor support is designed to be assembled with a variety of seal covers which are designed for Packing, Mechanical Seal and Labyrinth seals without modification.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 23
Installation
2
1
3
240
370L
412M
189
195
Item
Number
1.
2.
3.
Description
Support plate gasket
Pit cover
Pit cover gasket
Support plate
Discharge pipe
Motor support
Hardware, Support to plate
O-ring
Figure 9: Motor support and seal cover
Part Number
189
195
240
370L
412M
Install the packed stuffing box
WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.
The stuffing box is packed at the factory. The packing is lubricated by a grease cup supplied with the pump.
1. Fill the grease cup with any lithium-based #2 grease.
2. Install the grease cup on the tapped opening on the stuffing box.
3. Turn the cap on the grease cup several turns in order to inject the grease into the packing.
4. Hand-tighten the gland nuts.
24 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Installation
105
106
107
190G
193I
240
Lantern ring
Packing set
Gland
Pipe nipple
Grease cup
Motor support
Figure 10: Packed stuffing box
353
355
355C
364A
367B
494V
Gland stud
Gland nuts
Insert nuts
Packed box insert
Insert gasket
Pipe elbow
Install the pump, driver, and coupling
1. Mount and fasten the pump on the baseplate. Use applicable bolts.
2. Mount the driver on the baseplate. Use applicable bolts and hand tighten.
3. Install the coupling.
See the installation instructions from the coupling manufacturer.
Motor installation and coupling alignment
WARNING:
• Misalignment can cause decreased performance, equipment damage, and even catastrophic failure of frame-mounted units leading to serious injury. Proper alignment is the responsibility of the installer and the user of the unit. Check the alignment of all drive components prior to operating the unit.
• Follow the coupling installation and operation procedures from the coupling manufacturer.
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 25
Installation
NOTICE:
Proper alignment is the responsibility of the installer and the user of the unit. Check the alignment of frame-mounted units before you operate the unit. Failure to do so can result in equipment damage or decreased performance.
Install the motor
Use NEMA/IEC Vertical C-face motors with this pump.
1. Install both coupling halves before you mount the motor.
Refer to the instructions from the coupling manufacturer.
2. Use the lifting lugs on the motor in order to carefully lower the motor onto the pump.
Make sure to align the bolt holes.
3. Before you connect the coupling, wire the motor and check the direction of rotation.
The rotation arrow is on the motor support. The correct rotation is clockwise as you look down from the drive at the impeller.
Alignment checks
When to perform alignment checks
You must perform alignment checks under these circumstances:
• The process temperature changes.
• The piping changes.
• The pump has been serviced.
Types of alignment checks
Type of check
Initial alignment (cold alignment) check
Final alignment (hot alignment) check
When it is used
Prior to operation when the pump and the driver are at ambient temperature.
After operation when the pump and the driver are at operating temperature.
Initial alignment (cold alignment) checks
When Why
Before you grout the baseplate This ensures that alignment can be accomplished.
After you grout the baseplate This ensures that no changes have occurred during the grouting process.
After you connect the piping This ensures that pipe strains have not altered the alignment.
Final alignment (hot alignment) checks
When
After the first run
Why
This ensures correct alignment when both the pump and the driver are at operating temperature.
This follows the plant operating procedures.
Periodically
Permitted indicator values for alignment checks
NOTICE:
The specified permitted reading values are valid only at operating temperature. For cold settings, other values are permitted. The correct tolerances must be used. Failure to do so can result in misalignment.
When dial indicators are used to check the final alignment, the pump and drive unit are correctly aligned when these conditions are true:
• The Total Indicated Reading (T.I.R.) is at 0.05 mm | 0.002 in. or less at operating temperature.
26 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Installation
• The tolerance of the indicator is 0.0127 mm per mm | 0.0005 in. per in. of indicator separation for the reverse dial indicator or laser method when the pump and driver are at operating temperature.
Align the coupling
WARNING:
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
• Misalignment can cause decreased performance, equipment damage, and even catastrophic failure of frame-mounted units leading to serious injury. Proper alignment is the responsibility of the installer and the user of the unit. Check the alignment of all drive components prior to operating the unit.
• Follow the coupling installation and operation procedures from the coupling manufacturer.
•
• When installing in a potentially explosive environment, ensure that the motor is properly certified.
The coupling used in an ATEX classified environment must be properly certified.
Alignment of the pump and motor is of extreme importance for trouble-free mechanical operation. Straight-edge alignment by an experienced installer is adequate for most installations. Use dial indicators for disc couplings and applications where alignment to tighter tolerances is desirable. In these cases, use standard dial indicator procedures.
1. Check for coupling alignment by using either the reverse dial indicator method or laser alignment tools.
2. Refer to the coupling manufacturer literature for proper alignment criteria.
3. Install discs between the hubs per the manufacturer's directions included with the pump data package.
4. Tighten all motor bolts.
Float control installation
ITT supplies several different float controls. Refer to the float control installation instructions provided with the controls for the proper installation procedure. This topic describes the Square
D 9036 Simplex and Square D 9038 Duplex float controls.
How float controls work
The on and off levels of the Square D 9036 simplex and the Square D 9038 duplex are controlled by adjusting the collars (335). As the liquid level rises, the float rises to contact the upper collar and the upward movement of the float rod causes the mechanical switch inside the control to close. This completes the circuit to the starter. Operation continues until the liquid level drops low enough for the float to contact the lower collar. This pulls the rod down, opening the switch and turning off the pump.
The only difference between the Square D 9036 simplex and the Square D 9038 duplex is in the operating sequence. For the Square D 9038 duplex, the first pump starts as the water level rises. This allows the float to contact the upper collar. When the water level drops down and shuts off the first pump, a lever arm inside the control mechanically switches to the second pump and it comes on for the next cycle.
If the first pump fails to keep up with demand, or not come on at all, then a continued rise in the level turns both pumps on. Both pumps run until the low-water level is reached. If both pumps are unable to keep up with the demand, then an optional high-water alarm switch can be
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 27
Installation supplied in the alternator to close a switch if the water level rises past the second pumps on the level. This switch can be wired into a customer-supplied alarm horn or light.
APEX high level alarm
The APEX high level alarm is an independent device used to sense fluid level and close a switch that activates a separate alarm. The switch is mounted on a pipe above the support plate. The pipe must extend into the sump 10 to 15 cm | 4 to 6 in. below the required actuation point. As the liquid level rises in the pipe, trapped air causes bellows inside the switch to inflate and trip a microswitch. The switch can then activate a light, horn, relay, solenoid valve, or other electric device.
1.
High water alarm
2.
Reducing adapter, 13.0 mm x 26.0 mm | 0.5 in. x 1.0
in.
3.
Nipple, 26.0 mm | 1.0 in.
4.
Coupling, 26.0 mm | 1.0 in
5.
Pit cover
6.
Pipe, 26 mm | 1.0 in, 204 mm | 8.0 in. shorter than the pump length
7.
Cut the pipe 64 mm | 2.5 in. below the required switch actuation point
Figure 11: High water alarm
Magnetrol displacer-type liquid level switch
The Magnetrol displacer-type liquid level switch is closed by a magnetic seal inside a sealed tube. Switch operation is controlled by the buoyancy of weighted displacers suspended on a spring. As liquid level rises, the resulting change in buoyancy moves the spring upwards. The spring movement causes a magnetic sleeve to attract a pivoted magnet, closing the actuating switch. Refer to installation guide supplied by the manufacturer for proper installation and configuration.
Float ball switches
Float balls are individual switches that are used in multiple configurations to control the pump circuit. The float balls are suspended in the sump to the desired control level. When the fluid level rises to the float ball, the switch begins to float. The float is either anchored to a pipe or weighted. This allows the switch to tilt when the fluid continues to rise. When the float tilts, a switch closes that you can use in order to turn the pump on, activate a high-level alarm, or control any other electrical device.
Install the Square D 9036 simplex and 9038 duplex float controls
A single float and rod assembly is used with the 9036 float switch on a simplex unit or the 9038 duplex alternator. Refer to the wiring diagram from the manufacturer for the correct wiring of the switch.
If a pit cover is supplied with the pump, the float switch support pipe (435) and the upper rod guide (337) are installed by the factory. If the pit cover is supplied by others, you must locate, drill, and tap the holes before you install the switch.
28 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Installation
1.
Diameter of the coverplate (A)
2.
Radius (B)
3.
CL of the pump
4.
Radius of 178.0 mm | 7.0 in.
5.
1.25 in. NPT float switch NTG column
6.
0.38 in. NPT for the float rod guide
7.
203.0 mm | 8 in. diameter of float (standard)
Figure 12: Location of the float, rod, and switch
Number
1
2
3
Coverplate diameter (A)
559 mm | 22 in.
673 mm | 26.50 in.
787 mm | 31.00 in.
Radius (B)
368 mm | 14.50 in.
419 mm | 16.50 in.
470 mm | 18.50 in.
1. Before you install the pump in the sump, attach the lower guide arm (366) and the float rod guide (336) to the correct suction cover bolt (based on the layout).
2. Thread the float switch support pipe (435) and the upper rod guide (337) into the pit cover.
3. Attach the float switch bracket (398) to the float switch support pipe.
You can rotate the float switch around the center line of the pump on the radius (B).
4. Install the float rod (334), float (342), and collars (335).
You must maintain the radius (4) between the float switch column and the float.
Figure 13: Radius between float switch column and float
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 29
Installation
Piping checklists
General piping checklist
Precautions
WARNING:
• Risk of premature failure. Casing deformation can result in misalignment and contact with rotating parts, causing excess heat generation and sparks. Flange loads from the piping system, including those from the thermal expansion of the piping, must not exceed the limits of the pump.
• Risk of serious personal injury or property damage. Fasteners such as bolts and nuts are critical to the safe and reliable operation of the product. Ensure appropriate use of fasteners during installation or reassembly of the unit.
• Use fasteners of the proper size and material only.
• Replace all corroded fasteners.
• Ensure that all fasteners are properly tightened and that there are no missing fasteners.
CAUTION:
Never draw piping into place at the flanged connections of the pump. This can impose dangerous strains on the unit and cause misalignment between the pump and driver. Pipe strain adversely affects the operation of the pump, which results in physical injury and damage to the equipment.
NOTICE:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the suction side. This action can result in decreased performance, unexpected heat generation, and equipment damage.
Checklist
Check
Check that all piping is supported independently of, and lined up naturally with, the pump flange.
Explanation/comment
• Strain on the pump
• Misalignment between the pump and the drive unit
• Wear on the pump bearings and the coupling
Keep the piping as short as possible.
Check that only necessary fittings are used.
Do not connect the piping to the pump until:
• The grout for the pit cover becomes hard.
• The hold-down bolts for the pump and the driver are tightened.
This helps to minimize friction losses.
This helps to minimize friction losses.
—
Make sure that all the piping joints and fittings are airtight.
This prevents air from entering the piping system or leaks that occur during operation.
— If the pump handles corrosive fluids, make sure that the piping allows you to flush out the liquid before you remove the pump.
This helps to prevent misalignment due to linear expansion of the piping.
— Make sure that all piping components, valves and fittings, and pump branches are clean prior to assembly.
Checked
30 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Installation
Check
Make sure that the isolation and check valves are installed in the discharge line.
Use cushioning devices.
Explanation/comment
Locate the check valve between the isolation valve and the pump. This will permit inspection of the check valve.
The isolation valve is required for regulation of flow, and for inspection and maintenance of the pump. The check valve prevents pump or seal damage due to reverse flow through the pump when the driver is turned off.
This protects the pump from surges and water hammer if quick-closing valves are installed in the system.
Checked
Alignment criteria for pump flanges
Type
Axial
Parallel
Concentric
Criteria
The flange gasket thickness ±0.8 mm | 0.03 in.
Align the flange to be within 0.025 mm/mm to 0.8 mm/mm | 0.001 in./in. to
0.03 in./in. of the flange diameter.
You can easily install the flange bolts by hand.
Suction piping for optional dry pit, outside tank mount, and tailpipe applications
Checklist
Check Explanation/comment
Install an elbow at the pump.
Whenever possible, perform these actions:
• Use long radius elbows.
• Move the elbow further from the suction.
• Eliminate unneeded elbows.
Make sure that all joints are air tight.
Provide a method to prime the pump.
—
For outside tank mount and dry pit applications, allow the fluid level inside the tank or pit to rise above the casing level.
In tailpipe applications, submerge the casing before you start the pump.
For outside tank mount and dry pit applications, install an isolation valve in the suction line at least two pipe diameters from the suction.
This allows the line to be closed for pump inspection and maintenance. The isolation valve must be kept fully open during operation.
Make sure that the entrance to the suction pipe is kept adequately submerged below the free liquid surface.
This prevents vortices and air entrainment.
For an outside tank mount application, make sure that a column equalizing pipe assembly is installed.
The column assembly allows the fluid that comes through the lower bushings to flow up through the column and back through the equalizing pipe at the top of the column back to the tank.
Connect the equalizing pipe at the top of the pump column back to the source tank in order to prevent fluid from entering the thrust bearing.
Chec ked
Steam lines
Checklist
Check
Before you install the pump, become familiar with the location of the steam lines.
Explanation/comment
There are three connections above the support plate:
• Two steam connections
• One condensate return connection.
The steam connections are connected to the tops of the column and discharge jackets.
Checked
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 31
Installation
Check Explanation/comment
Determine which method to use in order to connect the steam lines.
There are two methods you can use in order to connect the steam lines:
• You can use both steam lines as input for steam
(preferred method).
• You can use one steam line as input for steam, while the other steam line is used as a feed through to additional pumps.
Only use this method if absolutely necessary, because it is difficult to control the steam at subsequent pumps.
Checked
Before you install the pump, check the fittings for leaks. Use plant air or high pressure water.
Provide source of steam at 35 psi and 149°C | 300°F.
After the pump is brought to temperature for the first time, shut down the unit temporarily and readjust the impeller clearance.
The jackets are hydrotested by the factory at 100 psi before shipment. However, the tube fittings can become loose during transit.
If you use air to check for leaks, use a soap solution at each joint in order to check for air bubbles.
Less than ideal conditions require higher pressure steam in order to keep the correct temperature.
Refer to Impeller clearance setting in the Operations chapter.
Final piping checklist
Check Explanation/comment
Check that the shaft rotates smoothly.
Rotate the shaft by hand. Make sure there is no rubbing that can lead to excess heat generation or sparks.
Re-check the alignment to make sure that pipe strain has not caused any misalignment.
If pipe strain exists, then correct the piping.
Checked
32 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
Commissioning, Startup, Operation, and
Shutdown
Preparation for startup
WARNING:
• Risk of serious physical injury or death. Exceeding any of the pump operating limits (e.g. pressure, temperature, power, etc.) could result in equipment failure, such as explosion, seizure, or breach of containment. Assure that the system operating conditions are within the capabilities of the pump.
• Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Ensure all openings are sealed prior to filling the pump.
• Breach of containment can cause fire, burns, and other serious injury. Failure to follow these precautions before starting the unit may lead to dangerous operating conditions, equipment failure, and breach of containment.
• Risk of explosion and serious physical injury. Do not operate pump with blocked system piping or with suction or discharge valves closed. This can result in rapid heating and vaporization of pumpage.
• Risk of breach of containment and equipment damage. Ensure the pump operates only between minimum and maximum rated flows. Operation outside of these limits can cause high vibration, mechanical seal and/or shaft failure, and/or loss of prime.
• Avoid mechanical seal failure or pump seizure by:
• increasing speed at startup to at least 65% of rated speed within 5 seconds and
• decreasing speed at shutdown from 65% of rated speed to 0 within 5 seconds
WARNING:
• Running a pump without safety devices exposes operators to risk of serious personal injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are properly installed.
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
Precautions
NOTICE:
• Verify the driver settings before you start any pump.
• Excessive warm-up rates can cause equipment damage. Ensure the warm-up rate does not exceed 1.4°C | 2.5°F per minute.
You must follow these precautions before you start the pump:
• Flush and clean the system thoroughly to remove dirt or debris in the pipe system in order to prevent premature failure at initial startup.
• Bring variable-speed drivers to the rated speed as quickly as possible.
• Run a new or rebuilt pump at a speed that provides enough flow to flush and cool the close-running surfaces of the stuffing-box bushing.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 33
Commissioning, Startup, Operation, and Shutdown
• If temperatures of the pumped fluid will exceed 93°C | 200°F, then warm up the pump prior to operation. Circulate a small amount of fluid through the pump until the casing temperature is within 38°C | 100°F of the fluid temperature. Accomplish this by flowing fluid from pump inlet to discharge drain (optionally, the casing vent can be included in warm-up circuit but not required). Soak for (2) hours at process fluid temperature.
At initial startup, do not adjust the variable-speed drivers or check for speed governor or overspeed trip settings while the variable-speed driver is coupled to the pump. If the settings have not been verified, then uncouple the unit and refer to instructions supplied by the driver manufacturer.
Check the rotation
WARNING:
• Starting the pump in reverse rotation can result in the contact of metal parts, heat generation, and breach of containment. Ensure correct driver settings prior to starting any pump.
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
1. Lock out power to the driver.
2. Make sure that the coupling hubs are fastened securely to the shafts.
3. Make sure that the coupling spacer is removed.
The pump ships with the coupling spacer removed.
4. Unlock power to the driver.
5. Make sure that everyone is clear, and then jog the driver long enough to determine that the direction of rotation corresponds to the arrow on the bearing housing or close-coupled frame.
6. Lock out power to the driver.
Lubricate bearings
Thrust bearing lubrication
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. Ensure bearings are properly lubricated prior to startup.
NOTICE:
During operation the oil level will change and appear higher do to circulation and foaming, this is normal.
Flood oil lubrication
Oil volumes
Oil volume requirements
Table 4: This table shows the required amount of oil for oil-lubricated bearings.
Frame ml Quarts
S 1065 1.12
Ounces
36
34 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
Frame
M
L ml
1185
1950
Quarts
1.25
2.06
Ounces
40
66
Lubricating-oil requirements
Oil requirements based on temperature
For the majority of operating conditions, bearing temperatures run between 49°C | 120°F and
82°C | 180°F, and you can use an oil of ISO viscosity grade 68 at 38°C | 100°F. If temperatures exceed 82°C | 180°F, refer to the table for temperature requirements.
Table 5: Oil requirements based on temperature
Temperature Oil requirement
Bearing temperatures exceed 82°C | 180°F Use ISO viscosity grade 100
Pumped-fluid temperatures exceed 177°C | 350°F Use synthetic lubrication.
Acceptable oil for lubricating bearings
Table 6: High quality turbine oils
Examples of acceptable high quality turbine oils with rust and oxidation inhibitors.
Brand Lubricant type
Chevron
Exxon
Mobil
Philips
GTS Oil 68
Teresstic EP 68
DTE 26 300 SSU @ 38°C | 100°F
Mangus Oil 315
Shell
Sunoco
Royal Purple
Tellus Oil 68
Sunvis 968
SYNFILM ISO VG 68 Synthetic Lube
Table 7: Synthetic lubricants
Examples of acceptable synthetic lubricants.
Brand
Castrol
Chevron
Exxon
Mobil
Shell
Sunoco
Texaco
Royal Purple
Lubricant type
Hyspin R&O 220
GST 220
Teresstic 220
DTE
Oil BB
Marlina 220
Tellus 220
Sunvis 9220
Regal R&O 220
Rando HD 220
Synfilm GT 220
Synergy 220
Lubricate the flood oil bearings
1. Remove the fill plug (113A).
2. Fill the bearing frame with oil through the filler connection, which is located on the side of the bearing frame.
Fill the bearing frame with oil until the oil level reaches the middle of the sight glass (319).
The correct volume of oil required for each size of bearing frame can be found in the ‘Oil
Volume Requirements’ section in the ‘Bearing Maintenance’ / ‘Maintenance’ portion of the
IOM.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 35
Commissioning, Startup, Operation, and Shutdown
113A
1
1. Correct level
Figure 14: Oil filler connection
3. Replace the fill plug.
Lubricate the bearings with oil
1. Remove the oiler.
Bar adjustment
1. Oiler
2. Adjustment assembly
3. Housing
2. Remove the adjustment assembly from the oiler.
3. Adjust the bars to dimension A as specified in
The oiler desired oil level setting should be 3.175 mm | 0.125" lower than the Frame oil level.
4. Lock in position.
5. Replace the adjustment assembly in the oiler.
6. Install the oiler.
7. Fill each bottle with oil and replace in the oiler housing.
The oil reservoir in the bearing housing is filled when the oil remains visible in the bottle.
You will need to fill the bottle several times.
Specification
Dimension A
Measurement
9.5 mm | 3/8 in.
36 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Specification
Dimension B
Oiler size
Commissioning, Startup, Operation, and Shutdown
Measurement
13 mm | 1/2 in.
#3 118 ml | 4 oz
Pure oil-mist lubrication
The inlet (IN) is stamped and located bearing end cover item 109. The outlet and drain ports are located on the opposite side of the oil frame as shown in the figure below. Connect the oil mist system supply to the IN port of the bearing end cover. The outlet for the oil frame can be connected to the outlet port or drain port. The recommended oil for the oil mist is an ISO VG
100. See the table for recommended oil mist airflows. Follow the instructions from the oil mist system supplier. The oil mist system must be interconnected with the pump so that the pump will shut down if the mist system fails
Table 8: Recommended oil mist airflows
This data is based on an oil/air ratio of 0.4 cubic inch (0.22 ounce) per hour per cfm.
Frame size Airflow in l/m | cfm
S/ST
M/MT
L
5.10 | 0.18
6.80 | 0.24
9.63 | 0.34
2
1
4
3
1. Bearing end cover
2. Oil frame
3. ½ NPT drain
4. ¼ NPT injection port
5. ¼ NPT outlet port
Figure 15: Pure oil-mist lubrication
5
Flush the steady bearings
There are five 1/4-in. NPT pipe plugs on the standard support plate that you use to connect the flush lines. Each plug connects with each of the five bearings. Pumps with less than five bearings still have five plugs, but only the required number are connected to bearings.
1. Remove the plugs from the holes that are connected to flush lines.
2. Connect an external source of clean water to the taps.
The water source must be able to deliver 1 to 2 GPM to each bearing.
3. Turn on the water in order to begin the flush.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 37
Commissioning, Startup, Operation, and Shutdown
Sealed bearings
Sealed bearings have a lip seal above and below the bearing in order to keep grit out of the bearing. Sealed bearings use a spring-loaded grease cup for lubrication. The bearings are prelubricated at the factory, but the grease cups ship in a separate box in order to prevent shipping damage. Fill the grease cups with grease and screw the cups into the taps that are connected to the bearings. Refill the cups with fresh grease as needed. Frequently inspect the grease cups after startup in order to check usage and establish the best relubrication interval.
123
197
213
333H
369
Figure 16: Sealed bearings
Deflector
Steady bearings
Housing, steady bearings
Lip seal
Retaining ring, steady bearing
Lubricate the sealed bearings with grease cups
For models with grease-lubricated bearings, the spring-operated automatic grease cups are designed to maintain constant lubrication of the intermediate pump bearings that are fixed to the vertical pump housing. The center stem protrudes out of the housing when the cup is full and gradually moves down into the housing as the grease is used. After the wing nut is threaded against the stem zerk fitting and the bottom of the wing nut rests on the cap of the grease cup, then the grease reservoir is empty and you must refill it.
38 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
1. Zerk fitting
2. Wing nut
3. Grease reservoir
4. Throttling screw
Figure 17: Lubicate with grease cups
Fill the housing
1. Turn the wing nut clockwise until the center stem is raised all the way and the wing nut does not turn any further.
2. Fit a pressurized grease gun to the top zerk fitting and pump the grease cup full until a small amount of grease starts to come out of the side vent of the housing.
3. Unthread the wing nut in order to energize the grease cup. Allow the internal spring pressure to push grease into the bearing lube line.
4. If the stem immediately recedes into the housing and the bearing has been purged, then complete these steps: a) Unthread the top lid in order to remove the top of the grease cup.
b) Inspect the plunger for defects.
If all the grease is found on the reverse (or back side) of the plunger, then it is defective and must be replaced.
Adjust the flow (preferred method)
1. Unthread the wing nut completely against the zerk fitting of the center stem.
2. Unlock the hex nut of the throttling screw and turn the slotted screw clockwise approximately one-half turn at a time.
3. Relock the hex nut and monitor the stem movement.
If the grease in the grease cup is completely consumed in 1 to 2 weeks of operation, then the flow is correct and will maintain the proper amount of grease to the bearings.
Adjust the flow (alternate method)
This method provides a more precise amount of grease to the bearings independent of changing operating temperatures and surrounding conditions. However, you must have a more controlled maintenance schedule in order to make sure this is done on a regular basis.
1. Leave the throttling screw locked and open.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 39
Commissioning, Startup, Operation, and Shutdown
2. Back off the wing nut several turns for every 2 to 3 days of operation.
Shaft sealing with a mechanical seal
Precautions
WARNING:
The mechanical seal used in an ATEX or Ex-classified environment must be properly certified. Prior to startup, make sure that all areas that could leak pumped fluid to the work environment are closed.
NOTICE:
• The mechanical seal must have an appropriate seal-flush system. Failure to do so will result in excess heat generation and seal failure.
•
• Cooling systems such as those for bearing lubrication and mechanical-seal systems must be operating properly to prevent excess heat generation, sparks, and premature failure.
• Sealing systems that are not self-purging or self-venting, such as plan 23, require manual venting prior to operation. Failure to do so will result in excess heat generation and seal failure.
Follow seal manufacturer's guidelines for proper seal installation procedures.
Shipping
Pumps may be shipped with or without a mechanical seal installed.
Cartridge-type mechanical seals
Cartridge-type mechanical seals are commonly used. Cartridge seals are preset by the seal manufacturer and require no field settings. Cartridge seals installed by the user require disengagement of the holding clips prior to operation, allowing the seal to slide into place.
Customers should always check to make sure the clips have been disengaged prior to starting the pump.
Other mechanical seal types
For other types of mechanical seals, refer to the instructions provided by the seal manufacturer for installation and setting.
Other shaft sealing options
1. Packed box - may be provided as an alternative to mechanical seals
2. Labyrinth seal - the seal cover may be fitted with a labyrinth seal if vapor emissions is not a problem.
Steam jacket pumps (molten sulfur construction)
The steam jacketed connections are located on the support plate. The "steam in" line is connected to an appropriate source of steam, and the "steam out/condensate" connections are made as dictated by the installation requirements. A suitable trap should be used.
Impeller-clearance setting
Importance of a proper impeller clearance
A proper impeller clearance ensures that the pump runs at high performance.
40 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
WARNING:
The impeller clearance setting procedure must be followed. Improperly setting the clearance or not following any of the proper procedures can result in sparks, unexpected heat generation, and equipment damage.
Set the impeller clearance - Dial indicator method
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
1. Lock out the driver power and remove the coupling guard.
2. Set the indicator so that the button contacts either the shaft end or the face of the coupling.
122
1
268 437B
283A
741
228
1. Dial indicator
Figure 18: Dial indicator setting
3. Remove Socket Head bolts (268) with Lockwasher (437B) from the EZ Adjust nut.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 41
Commissioning, Startup, Operation, and Shutdown
4. The EZ adjust nut (283A) can be rotated using both a ¼" round pin or a hook style spanner wrench.
1
2
42
1. 1/4" spanner wrench holes
2. Use slots for hook style spanner wrench
Figure 19: Rotate EZ adjust nut
5. Using a spanner wrench, rotate the EZ Adjust nut (283A) until the adjusting nut surface disengages from the bearing carrier (741) surface, the impeller is now in contact with the casing.
6. Rotate the shaft to ensure that there is contact between the impeller and the casing.
7. Set the dial indicator to zero.
8. Using a spanner wrench, rotate the EZ adjust nut (283A) clockwise, moving the shaft (122) away from the Bearing Frame until the indicator shows a clearance of 0.381 mm | 0.015".
9. Locate the Adjustment markings on the perimeter of the EZ adjust nut (283A) and the Bolt hole locator markings on the Bearing Carrier (741). They are in the form of lines and run in line with the shaft (122). On the EZ Adjust nut (283A), there will be two lengths of lines, the longer lines are to help align the holes.
122
268 437B
283A
741
1
2
1. 283A EZ adjust nut adjustment markings
2. 741 bearing carrier bolt hole location markings
Figure 20: Adjustment markings
10. Locate the Adjustment marking which are closest to a Bearing Carrier locator marking and rotate the ES adjust nut until the lines align.
11. Make sure the shaft turns freely.
12. Replace the Socket head bolts (268) with Lockwasher (437B) into the aligned holes, there will be 2 holes aligned 180° apart.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
122
Commissioning, Startup, Operation, and Shutdown
13. The Dial indicator reading may have changed up to 0.05 mm | 0.002" this is acceptable.
14. Make sure the shaft turns freely.
Set the impeller clearance – EZ Adjust method
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
1. Lock out the driver power and remove the coupling guard.
2. Remove Socket Head bolts (268) with Lockwasher (437B) from the EZ Adjust nut.
3. Using a spanner wrench, rotate the EZ adjust nut (283A) counterclockwise until the adjusting nut surface disengages from the bearing carrier (741) surface, the impeller is now in contact with the casing.
4. Rotate the shaft to ensure that there is contact between the impeller and the suction cover.
5. Rotate the EZ adjust nut (283A) clockwise, until the adjusting nut surface comes in contact with the bearing carrier surface (741)
6. Locate the Adjustment markings on the perimeter of the EZ adjust nut (283A) and the Bolt hole locator markings on Bearing carrier (741). They are in the form of lines and run in line with the shaft (122). On the EZ adjust nut (283A), there will be two lengths of lines, the longer lines are to help align the holes
7. Locate the adjustment marking (short or long) on the EZ adjust nut that is closest to a bearing carrier Bolt hole marking. Rotate the EZ adjust nut until they align. This now will be your zero point.
283A 1
741 2
268 437B
283A
741
1. 283A (Adjustment markings)
2. 741 (Bolt hole locator markings Zero Reference Mark
Figure 21: Zero reference mark
8. Count 7 markings (include all markings) on the EZ adjust nut, in a counter clockwise direction.
9. Rotate the EZ adjust nut (283A) clockwise until the 7 th mark is aligned with the zero mark on the bearing carrier (741).
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 43
Commissioning, Startup, Operation, and Shutdown
1
2
3
1. Zero Reference Mark
2. Count seven markings on EZ adjust nut
3. Rotate to zero mark
Figure 22: Rotate to zero mark
10. Look around the adjustment nut, there will now be two of the longer adjustment markings aligned with bearing carrier lines. Replace the Socket head bolts (283A) with Lockwasher
(437B) into these aligned holes, there will 2 holes aligned 180° apart.
1
44
2
1. Locate the larger mark in the EZ adjust nut that aligns with a bearing carrier line. Insert
Hardware.
2. Marks now aligned
Figure 23: Align marks
11. Make sure the shaft turns freely.
12. Replace the coupling.
13. Replace the coupling guard.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
NOTICE: Impeller clearance should be checked and re-adusted after pump has reached equilibrium temperature using methods as described in the sections above.
Pump priming
WARNING:
Ensure sump level is at or above minimum submergence level prior to starting pump.
CAUTION:
Do not run the pump dry.
Never start the pump until it has been properly primed. Fully submerge the pump casing prior to starting the pump.
For dry pit/outside tank mount units:
1. Ensure the suction supply line has adequate fluid head to prime the pump.
2. Slowly open the suction valve.
Install the coupling guard
WARNING:
• Running a pump without safety devices exposes operators to risk of serious personal injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are properly installed.
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
• The coupling guard used in an ATEX classified environment must be properly certified and constructed from a spark resistant material.
This pump is shipped without the coupling guard installed, because the motor and coupling are also not installed.
1. Mount the Guard Endplate (501A) to the End cover (109) using the End cover hardware
(370W).
2. Slide the two guard halves (501) between the Motor support and the bearing frame area.
One in each direction to form a circle. Each half will have tabs on one side which will engage each other, and the other a flange to mount to motor support.
3. Install the guard mounting hardware (388J).
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 45
Commissioning, Startup, Operation, and Shutdown
501
388J
2
240
109
1
370W
501A
1. Coupling spacer
2. Guard engagement, tab side
Figure 24: Coupling Guard Installation
Start the pump
WARNING:
Risk of equipment damage, seal failure and breach of containment. Ensure all flush and cooling systems are operating correctly prior to starting pump.
NOTICE:
• Risk of equipment damage due to dry operation. Immediately observe the pressure gauges. If discharge pressure is not quickly attained, stop the driver immediately, reprime, and attempt to restart the pump.
• To avoid risk of equipment damage, observe the pump for vibration levels, bearing temperature, and excessive noise. If normal levels are exceeded, shut down the pump and resolve the issue.
• On frame mounted units, ensure that the oil level is correct prior to starting pump.
NOTICE:
Risk of equipment damage on pure or purge-oil mist-lubricated units. Remove the viewing port plugs to verify that oil mist is flowing properly. Reinstall the plugs after confirming.
Before you start the pump, you must perform these tasks:
• Open any recirculation or cooling lines.
• Start the external bearing flush, if specified.
• Make sure the shaft rotates freely.
46 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
1. Fully close the discharge valve, depending on system conditions.
2. Start the driver.
3. Slowly open the discharge valve until the pump reaches the desired flow.
4. Immediately check the pressure gauge to ensure that the pump quickly reaches the correct discharge pressure.
5. If the pump fails to reach the correct pressure, perform these steps: a) Stop the driver.
b) Prime the pump again.
c) Restart the driver.
6. Monitor the pump while it is operating: a) Check the pump for bearing temperature, excessive vibration, and noise.
b) If the pump exceeds normal levels, then shut down the pump immediately and correct the problem.
A pump can exceed normal levels for several reasons. See Troubleshooting for information about possible solutions to this problem.
7. Repeat steps 5 and 6 until the pump runs properly.
Pump operation precautions
General considerations
NOTICE:
• Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the suction side. This action can result in decreased performance, unexpected heat generation, and equipment damage.
• Risk of equipment damage from unexpected heat generation. Do not overload the driver.
Ensure that the pump operating conditions are suitable for the driver. The driver can overload in these circumstances:
• The specific gravity or viscosity of the fluid is greater than expected
• The pumped fluid exceeds the rated flow rate.
• Do not operate pump past maximum flow. For maximum flow refer to pump performance curve.
• Do not operate pump below hydraulic or thermal minimum flow. For hydraulic minimum flows refer to technical manual and pump performance curves. To calculate thermal minimum flow, refer to HI Centrifugal Pump Design and Application ANSI/HI 1.3-2000.
• Make sure to operate the pump at or near the rated conditions. Failure to do so can result in pump damage from cavitation or recirculation.
Operation at reduced capacity
WARNING:
• Risk of breach of containment and equipment damage. Excessive vibration levels can cause damage to bearings, stuffing box, seal chamber, and/or mechanical seal. Observe pump for vibration levels, bearing temperature, and excessive noise. If normal levels are exceeded, shut down and resolve.
• Risk of explosion and serious physical injury. Do not operate pump with blocked system piping or with suction or discharge valves closed. This can result in rapid heating and vaporization of pumpage.
• Risk of equipment damage and serious physical injury. Heat build-up can cause rotating parts to score or seize. Observe pump for excessive heat build-up. If normal levels are exceeded, shut down and resolve.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 47
Commissioning, Startup, Operation, and Shutdown
NOTICE:
Cavitation can cause damage to the internal surfaces of the pump. Ensure net positive suction head available (NPSH
A
) always exceeds NPSH required (NPSH
3
) as shown on the published performance curve of the pump.
Operation under freezing conditions
NOTICE:
Do not expose an idle pump to freezing conditions. Drain all liquid that is inside the pump and any auxiliary equipment. Failure to do so can cause liquid to freeze and damage the pump.
i-ALERT
®
2 Equipment Health Monitor
WARNING:
Explosive hazard and risk of personal injury. Heating to high temperatures could cause combustion of the condition monitor. Never heat the condition monitor to temperatures in excess of 149°C | 300°F or dispose of in a fire.
For all information refer to the i-ALERT ® 2 Equipment Health Monitor Installation, Operation and
Maintenance manual.
Shut down the pump
WARNING:
Precautions must be taken to prevent physical injury. The pump may handle hazardous and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must be handled and disposed of in conformance with applicable environmental regulations.
1. Slowly close the discharge valve.
2. Shut down and lock out the driver to prevent accidental rotation.
48 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Commissioning, Startup, Operation, and Shutdown
Make the final alignment of the pump and driver
WARNING:
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
• Misalignment can cause decreased performance, equipment damage, and even catastrophic failure of frame-mounted units leading to serious injury. Proper alignment is the responsibility of the installer and the user of the unit. Check the alignment of all drive components prior to operating the unit.
• Follow the coupling installation and operation procedures from the coupling manufacturer.
You must check the final alignment after the pump and driver are at operating temperature. For initial alignment instructions, see the Installation chapter.
1. Run the unit under actual operating conditions for enough time to bring the pump, driver, and associated system to operating temperature.
2. Shut down the pump and the driver.
3. Remove the coupling guard.
See Remove the coupling guard in the Maintenance chapter.
4. Check the alignment while the unit is still hot.
See Pump-to-driver alignment in the Installation chapter.
5. Reinstall the coupling guard.
6. Restart the pump and driver.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 49
Maintenance
Maintenance
Maintenance schedule
Maintenance inspections
A maintenance schedule includes these types of inspections:
• Routine maintenance
• Routine inspections
• Three-month inspections
• Annual inspections
Shorten the inspection intervals appropriately if the pumped fluid is abrasive or corrosive or if the environment is classified as potentially explosive.
Routine inspections
Perform these tasks whenever you check the pump during routine inspections:
• Check for unusual noise, vibration, and bearing temperatures.
• Check the pump and piping for leaks.
• Analyze the vibration.
Three-month inspections
Perform these tasks every three months:
• Check that the foundation and the hold-down bolts are tight.
Annual inspections
Perform these inspections one time each year:
• Check the pump capacity.
• Check the pump pressure.
• Check the pump power.
If the pump performance does not satisfy your process requirements, and the process requirements have not changed, then perform these steps:
1. Disassemble the pump.
2. Inspect it.
3. Replace worn parts.
Bearing maintenance
These bearing lubrication sections list different temperatures of the pumped fluid. If the pump is ATEX-certified and the temperature of the pumped fluid exceeds the permitted temperature values, then consult your ITT representative.
NOTICE:
During operation the oil level will change and appear higher do to circulation and foaming, this is normal.
Thrust bearings
The pumps are shipped without oil. You must lubricate oil-lubricated bearings at the job site.
50 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Maintenance
Table 9: Lubricating intervals in operating hours
Type of bearing First lubrication
Oil-lubricated bearings Add oil before you install and start the pump. Change the oil after
200 hours for new bearings.
Lubrication intervals
After the first 200 hours, change the oil every 2000 operating hours or every three months.
Lubricate the bearings after a shutdown period
1. Flush out the bearings and bearing frame with a light oil to remove contaminants.
During flushing, make sure to rotate the shaft slowly by hand.
2. Flush the bearing housing with the proper lubricating oil to ensure oil quality after cleaning.
3. Refer to Reassembly section for proper bearing lubrication procedure.
Lubricating oil requirements
Refer to
Steady bearings
Check the ID of the casing collar (155) and steady bearing (197) per the dimensions in the
Bearing fits and tolerances table. If the ID is greater than what is allowed, remove the snap ring
(369) and use a suitable hydraulic press in order to remove these items for replacement. If sealed bearings are provided, then you must also remove the lip seals (333H).
The bearing ID is slightly larger before you press it into the housing in order to allow for ID shrinkage after you press it in place.
Shaft-seal maintenance
Removal and installation of Mechanical seal
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
1. Lock out the driver power and remove the coupling guard.
2. Drain oil from Bearing Frame (228).
3. Remove the Coupling spacer and pump half hub (233) and key.
4. Remove Socket head screws (268), Lockwasher (437B) and EZ adjust shaft nut (283A) from shaft.
5. Loosen and remove the End cover Hex Cap screws (370W) and Bearing frame End cover
(109) with Laby seal (332A).
6. Pull out the Bearing carrier assembly (741) and remove bearing carrier key (178S) from shaft. (Place the carrier assembly on a clean, flat surface. Wrap the carrier assembly in a clean towel to keep any dust or dirt from getting on the Angular Contact Bearings. It is very important to keep these bearings as clean as possible.)
7. Remove the Bearing frame (228) and mounting hardware (352D) from motor support.
8. Remove and service Mechanical seal.
9. After Service reassemble in reverse order.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 51
Maintenance
109
741
228
268 437B
283A
370W
332A
400
122
178S
352D
240
1
1. Mechanical seal
Figure 25: Mechanical seal
Mechanical-seal maintenance
WARNING:
The mechanical seal used in an ATEX or Ex-classified environment must be properly certified. Prior to startup, make sure that all areas that could leak pumped fluid to the work environment are closed.
CAUTION:
Running a mechanical seal dry, even for a few seconds, can cause seal failure and physical injury. Never operate the pump without liquid supplied to the mechanical seal.
Cartridge-type mechanical seals
Cartridge-type mechanical seals are commonly used. Cartridge seals are preset by the seal manufacturer and require no field settings. Cartridge seals installed by the user require disengagement of the holding clips prior to operation, allowing the seal to slide into place. If the seal has been installed in the pump by ITT, these clips have already been disengaged.
52 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Maintenance
Other mechanical seal types
For other types of mechanical seals, refer to the instructions provided by the seal manufacturer for installation and setting.
Reference drawing
The manufacturer supplies a reference drawing with the data package. Keep this drawing for future use when you perform maintenance and seal adjustments. The seal drawing specifies the required flush fluid and attachment points.
Before you start the pump
Check the seal and all flush piping.
If the pump is shipped with oil-lubricated seals, keep the seal faces lubricated with oil at all times.
Packed stuffing-box maintenance
WARNING:
• Packed stuffing boxes are not allowed in an ATEX-classified environment.
• Failure to disconnect and lock out driver power may result in serious physical injury. Never attempt to replace the packing until the driver is properly locked out.
Lubrication intervals
The lubrication intervals vary and depend upon the temperature and gland tightness. Keep the grease cup full at all times.
Periodically make several turns on the grease-cup cap while you inject fresh grease into the stuffing box. Check the pump daily upon initial operation, and extend this interval as required.
NOTICE:
Do not over-tighten the stuffing box. Excessive pressure can wear out packing prematurely and seriously damage the shaft.
Packing replacement
Replace the packing in this sequence:
1. Three rings of packing
2. Lantern ring
3. Two rings of packing
4. Gland
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 53
Disassembly
Disassembly
Disassembly precautions
WARNING:
• Failure to disconnect and lock out driver power may result in serious physical injury or death. Always disconnect and lock out power to the driver before performing any installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for specific instructions and recommendations.
• Risk of serious personal injury. Applying heat to impellers, propellers, or their retaining devices can cause trapped liquid to rapidly expand and result in a violent explosion. This manual clearly identifies accepted methods for disassembling units. These methods must be adhered to. Never apply heat to aid in their removal unless explicitly stated in this manual.
• Handling heavy equipment poses a crush hazard. Use caution during handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed shoes, gloves, etc.) at all times.
• Precautions must be taken to prevent physical injury. The pump may handle hazardous and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must be handled and disposed of in conformance with applicable environmental regulations.
• Risk of serious physical injury or death from rapid depressurization. Ensure pump is isolated from system and pressure is relieved before disassembling pump, removing plugs, opening vent or drain valves, or disconnecting piping.
• Risk of serious personal injury from exposure to hazardous or toxic liquids. A small amount of liquid will be present in certain areas like the seal chamber upon disassembly.
CAUTION:
• Avoid injury. Worn pump components can have sharp edges. Wear appropriate gloves while handling these parts.
Tools required
In order to disassemble the pump, you need these tools:
• Bearing puller
• Brass drift punch
• Cleaning agents and solvents
• Dial indicators
• Feeler gauges
• Hydraulic press
• Induction heater
• Lifting sling
• Micrometer
• Rubber mallet
• Screwdriver
• Snap-ring pliers
• Spanner wrench
• Torque wrench with sockets
54 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Disassembly
• Wrenches
• Lifting eyebolt (dependent on pump / motor size)
Drain the pump
CAUTION:
• Risk of physical injury. Allow all system and pump components to cool before handling.
• If the pumped fluid is non-conductive, drain and flush the pump with a conductive fluid under conditions that will not allow for a spark to be released to the atmosphere.
1. Close the isolation valves on the suction and discharge sides of the pump.
You must drain the system if no valves are installed.
2. Open the drain valve.
Do not proceed until liquid stops coming out of the drain valve. If liquid continues to flow from the drain valve, the isolation valves are not sealing properly and you must repair them before you proceed.
3. Leave the drain valve open.
Do not close the drain valve until the reassembly is complete.
4. Drain the liquid from the piping and flush the pump if it is necessary.
5. Disconnect all auxiliary piping and tubing.
6. Remove the coupling guard.
7. Disconnect the coupling.
8. Drain the oil from the bearing frame by removing the drain plug.
9. If applicable secure the mechanical seal and disconnect the seal piping.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 55
Disassembly
Remove the pump from the sump
1. Remove the motor bolts (371).
338
371 501
388J
1
228
1. Coupling
Figure 26: Motor bolts removal
2. Place the sling on the motor lifting lugs and remove the motor.
3. Remove the support plate anchor bolts.
4. Attach the eyebolts to the support plate.
5. Use properly-sized slings in order to lift the pump from the sump.
Refer to the Installation chapter for the proper handling procedure.
6. Lay the pump horizontally on proper supports where there is sufficient clearance to disassemble the pump.
56 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
7. Remove the bolts (317N) in order to remove the strainer (187).
Disassembly
Figure 27: Remove bolts to remove strainer
8. Remove the suction cover (182).
9. Remove and discard the suction cover gasket (351).
Replace the gasket during reassembly.
10. Remove the discharge elbow-casing bolts (370H).
11. Disconnect any steady bearing flush tubing (190).
Remove the impeller
CAUTION:
Risk of physical injury from sharp edges. Wear heavy work gloves when handling impellers.
1. Loosen and remove the impeller screw (198) and washer (199).
2. Pull the impeller (101 from the shaft.
Use a spanning-type puller if required.
Figure 28: Remove impeller
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 57
Disassembly
3. Remove the impeller key (178).
Save the key for reassembly unless it is damaged.
4. For L group models only, do the following: a) Remove the casing (100) to adapter (108) bolts.
b) Remove casing. Do not remove casing collar (155) at this time.
c) Remove the adapter (108) to column bolts.
d) Remove the adapter. Do not remove steady bearing (197) at this time.
Figure 29: Remove adapter
CAUTION:
Two people should handle any shaft over 9 feet long. Improper handling can bend the shaft.
Disassemble bearing frame
1. Remove the pump half coupling hub (233) and key.
2. Remove Socket head screws (268) and EZ adjust shaft nut (283A) from shaft.
3. Loosen and remove the End cover Hex Cap screws (370W) and Bearing frame End cover
(109) with Laby seal (332A).
4. Pull out the Bearing carrier assembly (741) and remove bearing carrier key (178S) from shaft. (Place the carrier assembly on a clean, flat surface. Wrap the carrier assembly in a clean towel to keep any dust or dirt from getting on the Angular Contact Bearings (112C). It is very important to keep these bearings as clean as possible.)
5. If applicable, loosen Packing Gland nut (355) and gland halves (107) or Mechanical seal gland hardware.
6. Remove the Bearing frame (228) and mounting hardware (352D) from Motor support.
58 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Disassembly
268
283A
370W
109
741
412
228
Figure 30: Bearing frame disassembly
122
178S
352D
364A 184
122
Figure 31: Seal removal
7. Remove packing insert (364A) with packing or Mechanical seal in seal cover (184).
8. Remove Shaft (122) through Motor support opening.
Disassemble the column
1. Remove the column down to the steady bearing housing bolts (372B).
If your pump has no intermediate steady bearings (only one column section), then skip this step since you do not have any column extension (306) or steady bearing housing (213).
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 59
Disassembly a) Start at the casing end of the pump and remove the column extensions (306), steady bearing housings (213), and deflectors (123) one at a time. Support the shaft in order to prevent bending while you remove these sections.
It is not necessary to remove the head column (192). Do not remove the steady bearings at this time. Refer to inspection procedures prior to removal.
Figure 32: Disassemble the column
60 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Preassembly inspections
Preassembly inspections
Replacement guidelines
Casing check and replacement
WARNING:
Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Inspect and ensure gasket sealing surfaces are not damaged and repair or replace as necessary.
Inspect the casing for cracks and excessive wear or pitting. Thoroughly clean gasket surfaces and alignment fits in order to remove rust and debris.
Repair or replace the casing if you notice any of these conditions:
• Localized wear or grooving that is greater than 3.2 mm | 1/8 in. deep
• Pitting that is greater than 3.2 mm | 1/8 in. deep
369 197 100
155
• Check the I.D. of the casing collar (155) and steady bearing (197) per the dimensions in
Bearing fits and tolerances (page 65). If the I.D. is greater than what is allowed, remove
the snap ring (369) and use a suitable hydraulic press to remove these items for replacement. If sealed bearings have been provided, you must also remove the lip seals
(333H).
• Inspect the casing-to-column connection area for any cracks or excessive corrosion damage. Replace if any of these conditions exist.
• Irregularities in the casing-gasket seat surface
Impeller replacement
Impeller parts
Impeller vanes
Vane edges
Pumpout vanes
When to replace
• When grooved deeper than 1.6 mm | 1/16 in., or
• When worn evenly more than 0.8 mm | 1/32 in.
When you see cracks, pitting, or corrosion damage
When worn or bent more than 0.8 mm | 1/32 in.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 61
Preassembly inspections
Gaskets, O-rings, and seats replacement
WARNING:
Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Replace all gaskets and O-rings at each overhaul or disassembly.
Fasteners
WARNING:
Risk of serious personal injury or property damage. Fasteners such as bolts and nuts are critical to the safe and reliable operation of the product. Ensure appropriate use of fasteners during installation or reassembly of the unit.
• Use fasteners of the proper size and material only.
• Replace all corroded fasteners.
• Ensure that all fasteners are properly tightened and that there are no missing fasteners.
Column sections
Inspect the column section(s) (306, 192) for any cracks or excessive corrosion damage.
Replace if necessary.
Motor support
Inspect the motor support (240) for any cracks or excessive corrosion damage. Replace if necessary.
Figure 33: Motor support
Shaft replacement guidelines
Shaft measurement check
Check the bearing fits of the shaft. If any are outside the tolerances shown in the Bearing fits and tolerances table, then replace the shaft.
Shaft inspection
Check the shaft straightness. Use "V" blocks or balance rollers to support the shaft on the bearing fit areas. Replace the shaft if runout exceeds 0.03 mm | 0.001 in.
NOTICE: Do not use shaft centers for the runout check as they may have been damaged during the removal of the bearings or impeller.
Shaft surface check
Check the shaft surface for damage. Replace the shaft if it is damaged beyond reasonable repair.
62 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Preassembly inspections
Figure 34: Shaft surface check
Bearings inspection
Condition of bearings
Do not reuse bearings. The condition of the bearings provides useful information on operating conditions in the bearing frame.
Checklist
Perform these checks when you inspect the bearings:
• Inspect the bearings for contamination and damage.
• Note any lubricant condition and residue.
• Inspect the ball bearings to see if they are loose, rough, or noisy when you rotate them.
• Investigate any bearing damage to determine the cause. If the cause is not normal wear, correct the issue before you return the pump to service.
Bearing Frame inspection
Disassembly
1. Loosen and remove the inside Rating Plate holding screws (371B) and Rating plate (549T).
2. Use a screwdriver in order to pry the labyrinth seal (332A) from the bearing frame (228).
371B
382U 549T 228
332A
Checklist
Figure 35: Bearing frame disassembly
Check the bearing frame for these conditions:
• Visually inspect the bearing frame for cracks.
• Check the inside surfaces of the frame for rust, scale, or debris. Remove all loose and foreign material.
• Make sure that all lubrication passages are clear.
• If the frame has been exposed to pumped fluid, inspect the frame for corrosion or pitting.
• Inspect bearing bore.
If the bore is outside the measurements in the Bearing fits and tolerances table, replace the bearing frame.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 63
Preassembly inspections
Surface inspection locations
This figure shows the areas to inspect for wear on the bearing carrier surfaces.
1
1. See thrust bearing fit
Figure 36: Inspect for wear on bearing carrier surfaces
Bearing carrier inspection
Disassembly
1. Place the spindle assembly upside down on a clean flat surface. Bend down any tabs which hold the Locknut Washer (382) to the Locknut (136).
136
382
112C
741
64
Figure 37: Spindle assembly
2. Hold the spindle securely so that it does not turn
CAUTION:
Do not damage the spindle in the process of securing it to a solid surface. The Laby Seal needs to be installed over the outside of the spindle.
3. Using a torque wrench or spanner wrench (supplied by others), loosen the Locknut (136), and remove the Locknut Washer (382).
4. With the Locknut (136) and Locknut Washer (382) removed, the bearings can now be pressed from the Bearing carrier (741). You will need a mechanical or hydraulic press to
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Preassembly inspections perform this step. Place the spindle on a round die which will allow clearance for the
Angular Contact Bearing (112) to be removed. Using blocks and/or tooling (supplied by others) press the inner race (only) of the angular contact bearings until they are free from the spindle.
1
1. Press inner race only
Figure 38: Press bearings from bearing carrier
Checklist
Check the bearing carrier for these conditions:
• Visually inspect the bearing carrier for cracks.
• Check all the surfaces of the carrier for rust, scale, or debris. Remove all loose and foreign material.
• Make sure that all lubrication passages are clear.
• If the carrier has been exposed to pumped fluid, inspect the frame for corrosion or pitting.
• Inspect carrier bearing mounting surface and shaft bore.
If the bearing mounting surface is outside the measurements in the Bearing fits and tolerances table, replace the bearing carrier.
Surface inspection locations
1
1. See thrust bearing fit
Figure 39: Areas to inspect for wear on the bearing carrier surfaces
Bearing fits and tolerances
Table 10: Steady bearing tolerances
This table references the bearing fits and tolerances according to ISO 286 (ANSI/ABMA Standard 7) in millimeters | inches.
Descripti on
Bearing ID (pressed into place)
S/ST
Carbon
M/MT
28.753–2
8.804 |
1.132–1.
134
L
41.478–4
1.529 |
1.633–1.
635
S/ST
57.353–5
7.404 |
2.258–2.
260
Housing bore
M/MT
41.173–4
1.224 |
1.621–1.
623
L
53.873–5
3.924 |
2.121–2.
123
S/ST
76.048–7
6.098 |
2.994–2.
996
Running clearance (1/2 diametrical clearance)
M/MT L
0.140–0.
089 |
0.0055–0
.0035
0.152–0.
102 |
0.006–0.
004
0.165–0.
102 |
0.0065–0
.004
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 65
Preassembly inspections
Descripti on
Bearing ID (pressed into place)
S/ST M/MT
Bronze 28.677–2
8.727 |
1.129–1.
131
Fluted elastomer
Rulon
28.600–2
8.702 |
1.126–1.
130
28.753–2
8.804 |
1.132–1.
134
L
41.377–4
1.427 |
1.629–1.
631
41.326–4
1.453 |
1.627–1.
632
41.478–4
1.529 |
1.633–1.
635
Casing collar
30.048–3
0.226 |
1.183–1.
190
42.621–4
2.799 |
1.678–1.
685
S/ST
57.302–5
7.353 |
2.256–2.
258
57.226–5
7.328 |
2.253–2.
257
57.353–5
7.404 |
2.258–2.
260
58.395–5
8.472 |
2.299–2.
306
-
Housing bore
M/MT
41.173–4
1.224 |
1.621–1.
623
41.173–4
1.224 |
1.621–1.
623
-
L
53.873–5
3.924 |
2.121–2.
123
53.873–5
3.924 |
2.121–2.
123
-
S/ST
76.048–7
6.098 |
2.994–2.
996
76.048–7
6.098 |
2.994–2.
996
45.999–4
6.126 |
1.811–1.
816
56.972–5
7.023 |
2.243–2.
245
82.372–8
2.423 |
3.243–3.
245
Running clearance (1/2 diametrical clearance)
M/MT
0.102–1.
051 |
0.004–0.
002
0.089–0.
013 |
0.0035–0
.0005
0.140–0.
089 |
0.0055–0
.0035
0.851–0.
737 |
0.0335–0
.029
L
0.102–1.
051 |
0.004–0.
002
0.114–0.
025 |
0.0045–0
.001
0.152–0.
102 |
0.006–0.
004
0.787–0.
673 |
0.031–0.
0265
0.140–0.
076 |
0.0055–0
.003
0.127–0.
102 |
0.005–0.
004
0.165–0.
102 |
0.0065–0
.004
0.737–0.
622 |
0.029–0.
0245
Table 11: Thrust bearing fits
Group
S
M
L
Carrier OD
45.012/45.002 |
1.7722/1.7717
60.014/60.002 |
2.3628/2.3623
85.019/85.004 |
3.3472/3.3466
Shell ID
85.023/85.001 |
3.3474/3.3465
110.022/110.000 |
4.3316/4.3307
145.025/145.000 |
5.9065/5.9055
Shaft runout tolerances
The following shaft runout tolerances apply to all size groups:
• Coupling end: 0.051 mm | 0.002 in.
• Shaft body: 0.0005 in./ft.
• Impeller end: 0.127 mm | 0.005 in.
66 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Reassembly
Reassembly
Assembly of Motor Support to Mounting Plate
Assemble Seal cover in Motor support
1. Install Seal cover (184) and O-ring (412P) inside Motor support (240) using mounting screws (371E).
2. Attach the Motor support (240) to support plate (189) with bolts (370L).
184
240
371E
412P
Figure 40: Install seal cover and O-ring
3. Attach the head column (192) to the motor support with bolts (370M). Make sure that the vent holes are closer to the motor support.
4. With the support plate in a vertical position, slide the shaft horizontally through the motor support. Support the shaft and column with suitable stands.
240 370L 412M
189
370M
192
Figure 41: Slide shaft horizontally through motor support
Assemble the column
If intermediate steady bearings are required, then you need additional column extensions (306) and steady bearing housings (213).
1. Prepare the steady bearing housing assemblies, if applicable.
You do not need to precisely center the steady bearing, and the holes in the bearing do not need to line up with the holes in the housing. A recessed area inside the housing (213) allows lubricants to find the opening in the bearing.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 67
Reassembly a) Remove the snap ring (369), if applicable.
b) Use a hydraulic press in order to press out the old steady bearing (197).
c) Press in the new steady bearing.
A snap ring (369) is no longer required due to the fits. If your pump has a snap ring, then it is not necessary to reinstall it. However, the snap ring is still required on sealed bearings.
2. Slide the casing assembly onto the shaft and seat the casing flange against the column flange.
Make sure the discharge nozzle is aligned with the discharge pipe hole in the support plate.
3. Install the bolts (371G).
Assemble the impeller, suction cover, and strainer
1. Add a film of oil to the shaft and place the impeller key (178) and impeller (101) on the shaft.
2. Check that all of the bearing shell bolts (370C and 370D) are completely backed off.
3. Install the impeller washer (199) and impeller screw (198).
When you tighten the impeller screw, the impeller will be seated on the shaft. The impeller screw has a nylon insert to lock it in place. Do not exceed these torque values when you tighten the impeller screw:
Group
S/ST
M/MT and L
Torque value
56 Nm | 500 in-lbs
102 Nm | 900 in-lbs
4. Install the suction cover gasket (351), suction cover (182), and strainer (187) with bolts
(317N).
Alloy strainers have extra-heavy spacer washers (533) between the strainer and the suction cover. If the unit is supplied with a lower-float control guide arm (366), then use an extra-long bolt in this hole.
Shaft sealing
WARNING:
The mechanical seal used in an Ex-classified environment must be properly certified.
CAUTION:
Running a mechanical seal dry, even for a few seconds, can cause seal failure and physical injury. Never operate the pump without liquid supplied to the mechanical seal.
Methods for sealing the shaft
These sections discuss the methods that you can use to seal the shaft.
• Seal the shaft with a labyrinth seal.
• Seal the shaft with a cartridge-mechanical seal.
• Seal the shaft with a packed stuffing box.
Seal the shaft with a Labyrinth seal
1. 1. Install Labyrinth Seal (383A) in seal cover (184).
68 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
383A
184
Reassembly
Figure 42: Labyrinth seal
Seal the shaft with a packed stuffing box
WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury. Never attempt to replace the packing until the driver is properly locked out.
Pumps are shipped without the packing, lantern ring, or split gland installed. These parts are included with the box of fittings shipped with each pump and must be installed before startup.
1. Carefully clean the stuffing-box bore (364A).
2. Install stuffing box insert (364A) and two mounting studs (353) in seal cover (184).
3. Twist the packing (106) enough to get it around the shaft.
Packing rings
1
Lantern rings
2
3 4
3
1.
Packing rings
2.
Lantern rings
3.
Correct
4.
Incorrect
Figure 43: Packing rings and lantern rings
4. Insert the packing and stagger the joints in each ring by 90º.
Install the stuffing box parts in this order: a) Three packing rings (106) b) One lantern ring (105) c) Two packing rings (106)
5. Install the gland halves (107) and evenly hand-tighten the nuts (355).
4
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 69
Reassembly
NOTICE:
Do not overtighten gland nuts. Overtightened packing causes excessive friction between packing and sleeve and will result in damaged components.
355
107
353
105
106
364A 184
Figure 44: Install gland halves
Seal the shaft with a cartridge mechanical seal
WARNING:
The mechanical seal used in an Ex-classified environment must be properly certified.
Prior to startup, make sure that all areas that could leak pumped fluid to the work environment are closed.
NOTICE:
The mechanical seal must have an appropriate seal flush system. Failure to do so will result in excess heat generation and seal failure.
1. Slide the cartridge seal into the seal chamber and secure using the four studs and nuts.
2. Continue with the pump reassembly.
3. Set the impeller clearance.
Refer to the Impeller clearance setting topic for more information.
4. Tighten the setscrews in the seal locking ring in order to secure the seal to the shaft.
5. Remove the centering clips from the seal.
70 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
1
184
Reassembly
1. Mechanical seal
Figure 45: Cartridge mechanical seal
Assemble bearing frame
NOTICE:
Make sure that the pipe threads are clean, and that you apply thread sealant to the plugs and fittings.
382U 371B
549T
408J
408A
113A
319
761B
113
228
333
Figure 46: Bearing frame assembly
Prepare the bearing frame (228) as follows (see the illustration):
1. Install Rating Plate (549T) using mounting screw (371B) with lockwasher (382U) in bearing frame (228).
2. Install Labyrinth Seal (333) in the bearing frame (228).
3. Install the oil-fill plug (113A).
4. Install the oil-drain plug (408A).
5. Install the sight glass (319).
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 71
Reassembly
6. Install the sight oiler plug (408J).
7. Install the plug for Greased lube option (113).
Assemble Bearings on carrier
CAUTION:
• Mount the bearing in a clean environment. The Carrier (741) and other components of the bearing arrangement should be checked to see that they are clean. The bearings should be left in their original packages until immediately before mounting so that they do not become dirty.
• Risk of physical injury from hot bearings. Wear insulated gloves when using a bearing heater.
1. Clean the carrier (741). Remove any residual grease or contaminants. Secure the Spindle upside down in the vertical position
2. Heat the Angular Contact Bearings (112C) using an induction heater to about 80 to 90 °C |
160°F to 170°F. Refer to
Figure 47: Bearing heater (page 72) for a typical bearing induction
heater.
Figure 47: Bearing heater
72 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Reassembly
WARNING:
There are several methods you can use to install bearings. The recommended method is to use an induction heater that heats and demagnetizes the bearings.
Figure 48: Do not use torch to heat bearings
3. Install the Angular Contact Bearings (112C) onto the carrier (741). It is critical that the
Angular Contact Bearings be installed in the correct orientation.
Angular Contact Bearing need to be installed in what is considered the down thrust orientation. This means that the larger outer races together (back-to-back).
741
112C
382
136
Assemble bearings back-to-back
Figure 49: Bearing assembly
4. Position the bearings (112C) on the carrier (741) against the shoulder and snug the locknut
(136) against the bearings until they are cool.
The locknut prevents the bearings from moving away from the shaft shoulder as they cool.
Rotate the outer bearing rings relative to each other as they are placed on the shaft to assure good alignment.
5. Remove the bearing locknut (136) after the carrier (741) are cool.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 73
Reassembly
6. Put the lockwasher (382) onto the carrier (741) Make sure that the tang of lockwasher is in the keyway of the carrier.
7. Thread the locknut (136) onto the carrier (741) and tighten it until it is snug.
8. Bend the tangs of the lockwasher into the slots of the locknut.
Assemble the bearing frame, bearing carrier and end cover
1. Slide the bearing frame (228) onto the shaft and mount to motor support (240) using mounting hardware (352D).
2. Install the Key (178S) onto the Shaft (122). Goulds recommends putting a small amount of adhesive on the Key, and securing to the Shaft. This will make installing the Bearing Carrier
(741) assembly much easier.
1
178S
122
1. Adhesive
Figure 50: Install key on shaft
3. Slide the Bearing Carrier Assembly (741) onto the shaft. Align the internal keyway in the
Carrier to the Key (178S) and lower into the Bearing Frame (228) until the Carrier Bearings bottom out in the Bearing Frame.
4. Install the O-ring (412) into the Bearing Frame O-Ring groove (228).
5. Install the Endcover (109) using the mounting bolts (370W). When installing the cover, make sure to align the notch in the cover over the Oil fill connection.
74
1
1. Align notch in cover
Figure 51: Align notch in cover
6. Install the outboard labyrinth oil-seal (332A) over the Bearing Carrier OD (741) and into the end cover (109). Press into cover referencing the figure below.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Reassembly
NOTICE:
If labyrinth oil-seal (332A) is preassembled in end cover (109), do not press on end cover to install, refer to figure below for acceptable force application. Labyrinth oil-seal (332A) seal may be damaged if force is applied to end cover (109).
1 1
1. Press here
Figure 52: Acceptable force application
7. Slide the EZ adjust nut (283A) on to the shaft (122) and thread onto shaft until it contacts the Bearing Carrier.
268
283A
370W
109
741
412
228
122
178S
352D
Figure 53: Slide EZ adjust nut onto shaft
8. Using the EZ adjust nut (283A), check the axial travel of the impeller.(Refer to the Impellerclearance setting section in “Commissioning, Startup, Operation and Shutdown for the procedure).
If the travel is less than 0.762 mm | 0.030 in., then add extra gaskets (351) in order to obtain the minimum travel.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 75
Reassembly
Assemble the discharge elbow, pipe and auxiliary piping
1. Install the discharge elbow gasket (351A) and the discharge elbow (315) using bolts
(370H).
Accurate alignment of the elbow is critical in order to make sure that there is no obstruction to the flow through the connection.
2. Install the discharge pipe (195), pipe nuts (242), and flange (195S, if used). Make sure that the pipe nuts are tight and that there is no strain on the pump.
3. Rotate the shaft by hand in order to make sure that there is no binding.
4. Connect all auxiliary piping.
5. Replace the pump half coupling hub (233) and lubricate the pump bearings.
76 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Troubleshooting
Troubleshooting
Operation troubleshooting
Symptom
The pump is not delivering liquid.
The pump is not producing the rated flow or head.
The pump starts and then stops pumping.
The bearings are running hot.
The pump is noisy or vibrates.
Cause
The pump is not primed.
The discharge head it too high.
Remedy
Make sure the pit is filled with liquid above the casing. On dry pit units, the casing and suction pipe must be completely filled.
Check the total head, particularly friction loss.
The motor speed is too low.
The suction line is clogged.
The impeller, discharge pipe, or strainer is clogged.
The shaft is rotating in the wrong direction.
Check the motor speed.
Remove the obstructions.
Remove obstructions or back-flush the pump.
The suction lift is too high.
The amount of available NPSH is not sufficient.
Change the rotation. The rotation must match the arrow on the bearing housing or pump casing.
The shaft is rotating in the wrong direction.
Change the rotation. The rotation must match the arrow on the bearing housing or pump casing.
The discharge head is higher than expected.
Check the total head, particularly friction loss.
The impeller, discharge pipe, or strainer is clogged.
The motor speed is too low.
Shorten the suction pipe.
Check the amount of NPSH available and required and adjust accordingly.
Remove obstructions or back-flush the pump.
Check the motor speed.
The suction line is clogged.
The suction lift is too high.
The impeller is worn or broken.
The suction line has air or vapor pockets.
The amount of available NPSH is not sufficient.
The pump is not primed.
Remove the obstructions.
Shorten the suction pipe.
Inspect and replace the impeller if necessary.
Rearrange the piping in order to eliminate air pockets.
Check the amount of NPSH available and required and adjust accordingly.
Re-prime the pump and check that the pump and suction line are full of liquid.
The float controls are not adjusted properly.
Check the float controls.
The strainer is clogged.
Check the sump for large items that the pump may be picking up. Check if the bearings are running hot.
The suction line has air or vapor pockets.
Rearrange the piping in order to eliminate air pockets.
The suction line has an air leak.
Repair the leak.
The pump and driver are not aligned properly. Realign the pump and driver.
There is not sufficient lubrication.
Check the lubricant for suitability and level.
The lubrication was not cooled properly.
Check the cooling system.
The pump and driver are not aligned properly. Realign the pump and driver.
The impeller is partly clogged.
The impeller or shaft is broken or bent.
Back-flush the pump in order to clean the impeller.
Replace the impeller or shaft as necessary.
The foundation is not rigid.
The bearings are worn.
Rotating parts are loose, broken, or rubbing against each other.
The suction or discharge piping is not anchored or properly supported.
The pump is cavitating.
Tighten the hold-down bolts of the pump and motor. Make sure that the base plate is properly grouted without voids or air pockets.
Replace the bearings.
Replace parts as necessary.
Anchor the suction or discharge piping as necessary according to recommendations in the Hydraulic Institute Standards Manual.
Locate and correct the system problem.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 77
Troubleshooting
Symptom
The motor requires excessive power.
Cause Remedy
The discharge head has dropped below the rated point and is pumping too much liquid.
Install a throttle valve. If this does not help, then trim the impeller diameter. If this does not help, then contact your ITT representative.
The liquid is heavier than expected.
Check the specific gravity and viscosity.
Rotating parts are rubbing against each other. Check the parts that are wearing for proper clearances.
The motor speed is too high.
The impeller clearance is too tight.
Check the motor speed.
Adjust the impeller clearance.
Assembly troubleshooting
Table 12: Troubleshooting procedure
Symptom
There is excessive shaft end play.
The runout for the shaft is excessive.
The runout for the bearing-frame flange is excessive.
The runout for the seal-chamber cover is excessive.
The runout for the impeller wear ring is excessive.
Cause
The internal clearance of the bearings is excessive.
The thrust-bearing end cover is loose.
Remedy
Replace the bearings with a bearing of the correct type.
Tighten the screws.
The shaft is bent.
The shaft is bent.
Replace the shaft.
Replace the shaft.
The flange of the bearing frame is distorted. Replace the bearing-frame flange.
The seal-chamber cover is improperly seated on the frame.
Replace or re-machine the sealchamber cover.
Replace the seal-chamber cover.
There is corrosion or wear on the sealchamber cover.
The shaft is bent.
The wear ring was machined improperly.
Replace the shaft.
Replace or re-machine the impeller.
i-ALERT
®
2 Equipment Health Monitor troubleshooting
To troubleshoot t the i-ALERT ® 2 Equipment Health Monitor, please refer to the i-ALERT ® 2
Equipment Health Monitor IOM or
78 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Cross-sectional diagram
Cross-sectional diagram
1
2
3
1.
Enlarged frame section
2.
Stuffing box with packing option
3.
Mechanical seal option
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 79
Dimensional drawings
Dimensional drawings
Exploded view A
268 437B
Exploded view B
283A
741
112C
382
136
332A
370W
109
549T
412
371B 382U
228
333
240
355
353
107
107
364A
184
412P
105
352D
370L
412M
178S
122
371F
80 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Parts list
Parts list
Table 13: Parts list with materials of construction
Item Quantity Part name S-1/S-4 S-3
100
101
105
106
107
1
1
1
Set
1
Casing
Impeller
Lantern ring
Packing
Gland
A216 WCB (1212)
A536 65-
45-12
(1018)
A436
Type 2
(1007)
As specified
As specified
1000 or 1203
S-5
A216
WCB
(1212)
S-6 S-8
A487
CA6NM
(1234)
A743
CF8M
(1203)
A-8
A743
CF8M
(1203)
A743
CF8M
(1203)
D-1
A890
Grade
4A
(1360)
A890
Grade
4A
(1360)
108 1
Casing from adapter (L group only)
A216 WCB (1212)
A743
CF8M
(1203)
A890
Grade
4A
(1360)
109 1
112C 2
End cover
Thrust bearing
2201
Angular contact with machined brass cage
122 1 Shaft A582 S41600 (2218)
D-2
A890
Grade
5A
(1361)
A890
Grade
5A
(1361)
A890
Grade
5A
(1361)
A276
S31600
(2216)
A276
S31803
(2478)
A479
S32750
(3273)
123
136
155
178 1
178S 1
1
1
1
Deflector
Bearing locknut
Casing bushing
Impeller key
Bearing carrier key
Neoprene
Steel
Carbon-filled PTFE (PTFE)
2229
2213
2248
182 1 Suction cover A216 WCB (1212)
A743
CF8M
(1203)
A890
Grade
4A
(1360)
A890
Grade
5A
(1361)
184 1 Seal cover 2201
187 1 Strainer 3211
A890
Grade
4A
(1360)
A890
Grade
5A
(1361)
189
190
190G 1
1
1
Support plate
Flush tubing
Pipe nipple
3201
As specified
Steel
192 1 Head column A53 Grade F (6501)
A312
316L
(6545)
A790
S31803
(6762)
A790
S32750
(6682)
193I 1 Grease cup Steel
195 1 Discharge pipe A53 Grade F (6501)
A312
316L
(6545)
A790
S31803
(6762)
A790
S32750
(6682)
197
198
199
213
1
1
1
1
Steady bearings
Impeller screw
Impeller washer
Steady bearing housing
Carbon or as specified
2229
2229
A216 WCB (1212)
2248
2248
A890
Grade
4A
(1360)
A890
Grade
5A
(1361)
228
240
283A 1
1
1
Bearing frame
Motor support
Adjustment nut
1212
1000
2201
306 1 Column extension A53 Grade F (6501)
A312
316L
(6545)
A790
S31803
(6762)
A790
S32750
(6682)
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 81
Parts list
Item
315
Quantity
1
Part name
Discharge elbow
S-1/S-4 S-3
A216 WCB (1212)
S-5 S-6 S-8 A-8
A351
CF3M
(1296)
D-1
A890
Grade
4A
(1360)
D-2
A890
Grade
5A
(1361)
332A
333
351
351A
364A 1
367B 1
369A 1
370G 6
370H 4
370M
372B
1
1
1
1
6
6
382
383
412 1
412M 1
412P 1
494V 1
1
1
536E 1
543E 1
549T 1
Labyrinth seal, upper
Labyrinth seal, lower
Gasket, suction cover to casing
Gasket, discharge elbow to casing
Stuffing box
Gasket, stuffing box insert
Bearing collar
Bolt, column-to-casing
Bolt, elbow-to-casing
Bronze INPRO
Bronze INPRO
Nitrile acrylic
Nitrile acrylic
1203
Nitrile acrylic
Steel
A193 B8M (2272)
A193 B8M (2272)
Bolt, head column-to-motor support
Bolt, head column-to-column extension
Bearing lockwasher
Mechanical seal
O-Ring, end cover
O-Ring, motor support
O-Ring, seal cover
Pipe elbow
A193 B8M (2272)
As specified
Steel
As specified
Nitrile
Nitrile
Nitrile
1000
Tube fitting, steady bearing As specified
Tube fitting, support plate As specified
Rating plate Steel
571E 1
Discharge elbow flange (L group only)
741 1 Bearing carrier
1 The quantity depends on pump length.
A216 WCB (1212)
2201
2218
2229
2248
2272
2478
3201
3211
3273
6501
6545
6682
6762
Table 14: Material code cross reference
Goulds code
1000
1007
1018
1203
1212
1234
1296
1360
1361
2210
2216
ASTM number
A48 CL25B cast iron
A436 Type 2 Ni-Resist
A536-84 60-42-10 ductile iron
A743 CF8M 316 stainless
A216 WCB carbon steel
A487 GR CA-6NM Class A
A351 GR CF-3M
A890 Grade 4A 22Cr-5Ni-Mo-N
A890 Grade 5A 25Cr-7Ni-Mo-N
A108 Gr1211 carbon steel
A276 316 stainless ground and polished
A582 Type 416 stainless steel
A276-91A stainless
B574 C-276 Hastelloy C
A193 B8M AISI Grade 316 alloy steel
A479 Type S 31083
A283 Grade D carbon steel plate
A240 316 steel plate
A479 Alloy 2507 (annealed) turned, ground, and polished
A53 Type F carbon steel schedule 40 pipe
A312 316L stainless steel schedule 40 pipe
A790 Alloy 2507 schedule 40 pipe
A790 GR S 31803 stainless steel welded pipe
2248
2248
A351
CF3M
(1296)
A890 Grade 4A
(1360)
82 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Other Relevant Documentation or Manuals
Other Relevant Documentation or Manuals
For additional documentation
For any other relevant documentation or manuals, contact your ITT representative.
Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual 83
Local ITT Contacts
Local ITT Contacts
Regional offices
Region Address
North America (Headquarters) ITT - Goulds Pumps
240 Fall Street
Seneca Falls, NY 13148
USA
Houston office 12510 Sugar Ridge Boulevard
Stafford, TX 77477
USA
Los Angeles Vertical Products Operation
3951 Capitol Avenue
City of Industry, CA 90601-1734
USA
Asia Pacific
Europe
Latin America
Middle East and Africa
ITT Fluid Technology Asia Pte Ltd
1 Jalan Kilang Timor
#04-06 Singapore 159303
ITT - Goulds Pumps
Millwey Rise Industrial Estate
Axminster, Devon, England
EX13 5HU
ITT - Goulds Pumps
Camino La Colina # 1448
Condominio Industrial El Rosal
Huechuraba Santiago
8580000
Chile
ITT - Goulds Pumps
Achileos Kyrou 4
Neo Psychiko 115 25 Athens
Greece
Telephone
+1 315-568-2811
+1 281-504-6300
+1 562-949-2113
+65 627-63693
+44 1297-639100
+562 544-7000
+30 210-677-0770
Fax
+1 315-568-2418
+1 281-504-6399
+1 562-695-8523
+65 627-63685
+44 1297-630476
+562 544-7001
+30 210-677-5642
84 Model API 3171 Flood Oil Lubrication Installation, Operation, and Maintenance Manual
Visit our website for the latest version of this document and more information: http://www.gouldspumps.com
Goulds Pumps Inc.
240 Fall Street
Seneca Falls, NY 13148
USA
© 2019 ITT Corporation
The original instruction is in English. All non-English instructions are translations of the original instruction.
Form IOM.API3171-OilLube.en-US.2019-07