Air TEc BK2000 How-To Manual

Air TEc BK2000 How-To Manual

Air TEc BK2000 is a powerful and versatile vacuum cleaner that comes with a variety of attachments to help you clean your home quickly and efficiently. The BK2000 features a 3-way filter assembly with a charcoal/carbon filter to trap dust, pollen, and other allergens, making it ideal for homes with allergy sufferers. The disposable AlleRx bags are easy to replace, and the power head can be used with or without the attachments for added versatility. Attachments include a power nozzle, straight wands, a dusting brush, an upholstery tool, and a crevice tool.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Air TEc BK2000 How-To Manual | Manualzz

T h e e B K 2 0 0 0 H o w t t o G u i i d e

Note: The following pages have been taken from The BK’s Owner’s Manual.

Table of Contents

1. Disposable Bag Removal/Replacement

2. Filter Removal/replacement

3. Assembling and Using the Power Head

4. Assembling and Using other Attachments

5. Troubleshooting your BK2000

Page

3

3

2

2

4

1 .

.

D i i s s p o s s a b l l e B a g R e m o v a l l / / R e p l l a c e e m e n t t

1. Use genuine AlleRx bags only; failure to do so will void warranty immediately. Unplug the power head.

2. Remove the front-end bell by first releasing the front-end clamps.

3. Remove the bag from the unit and replace it with a new AlleRx bag.

4. Replace the front-end bell and fasten the front-end clamps. TOP label on the front-end bell should face up.

2 .

.

F i i l l t t e r R e m o v a l l / / R e p l l a c e m e n t t

1. Use genuine 3-way filter assembly only; failure to do so will void warranty. Remove the front-end bell and bag by following the instructions above.

2. Remove and discard the used filter.

Place 3-way filter assembly with charcoal/carbon filter facing motor.

3. Replace the bag, then the front-end bell and finally fasten the front-end clamps.

2

3 .

.

A s s s s e m b l l i i n g a n d U s s i i n g t t h e P o w e r H e a d

1. Grasp hose connector, position over pins on front-end bell and rotate clockwise until locked. Make sure electric cord is on the TOP.

2. Insert male plug into handle electric plug (located on top of the handle) Push in until it makes contact.

3. Attach straight wands.

4. Insert the straight wand into the power nozzle by aligning the springloaded button with the hole in power nozzle tube.

5. Insert power cord into channel on wand.

4 .

.

A s s s s e m b l l i i n g a n d U s s i i n g o t t h e r A t t t t a c h m e n t t s s

1. Follow instructions to assemble the electric hose already given here.

2. Slip the tool on the lower wand by passing the groove and depressing the locking lever on it.

3. Some attachments such as the dusting brush, the upholstery tool, and the crevice tool can be plugged directly to the hose. Remove the wand first, then add the tool to the end of the hose. When slipping attachment, twist slightly for a friction lock.

3

Problem

Caution : to reduce the risk of personal injury, UNPLUG the unit before servicing it.

Cleaner won’t run

Cleaner shuts off suddenly

Cleaner won’t pick up

Tools won’t pick up

Dust escaping from cleaner

Brushroll is not rotating

5 .

.

T r o u b l l e s s h o o t t i i n g y o u r B K 2 0 0 0

Possible Reason(s) Possible solution(s)

1. Power cord not plugged into outlet

2. Blown fuse or broken switch

1. Heat sensor detected excessive heat and turned off the unit automatically

1. AlleRx bag is full or missing

2. Broken or worn belt

3. Clogged 3-Way filter assembly

4. Power nozzle to hose passage is clogged

1. Hose clogged

2. AlleRx bag or 3-way filter assembly clogged

3. Handle cord not properly connected

1. AlleRx bag is not installed properly, punctured, or missing

1. Belt missing or not assembled properly

2. Brushroll clogged or bound with hair or string

3. Worn Brushroll Bearings

1. Plug unit in firmly

2. Replace part

1. Unplug, wait 30 min, press switch twice and resume cleaning

1. Replace bag

2. Replace belt

3. Replace filter

4. Remove nozzle, remove obstruction from nozzle or from hose

1. Remove tool, remove obstruction

2. Replace bag or filter

3. Make sure cord makes full contact w/unit

1. Replace bag and filter assembly

1. Replace belt

2. Remove clog, cut & remove hair and string

3. Replace brushroll bearings

1. Clogged or partially clogged brushroll Refer to “Brushroll is not rotating” above Belt burns/breaks

Any other servicing should be done by an authorized service agent